Scielo RSS <![CDATA[Nucleus]]> http://scielo.sld.cu/rss.php?pid=0864-084X20080001&lang=pt vol. num. 43 lang. pt <![CDATA[SciELO Logo]]> http://scielo.sld.cu/img/en/fbpelogp.gif http://scielo.sld.cu <![CDATA[<strong>Radiation induced graft copolymerization of acrylamide onto poly (3-hydroxybutyrate)</strong>]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2008000100001&lng=pt&nrm=iso&tlng=pt The graft copolymer poly (3-hydroxybutyrate)-g- polyacrylamide[P (HB-g-AAm)] was synthesized by radiation induced graft copolymerization of acrylamide onto poly (3-hydroxybutyrate). The study was conducted by the simultaneous irradiation method. The structure of [P (HB-g-AAm)] was identified by Fourier Transform Infrared (FTIR) spectroscopy. Thermal behavior of the graft copolymer was also studied by Thermal Gravimetric Analysis (TGA) and Differential Scanning Calorimetry (DSC). According to the results, FTIR studies showed new signals (stretching-N-H) as an important evidence of grafting. The grafting degree, determined by ATG, was 10% and changes in thermodynamic parameter obtained from the DSC were detected. Such changes show a decrease in crystallinity and an increase in the glass transition temperature. These results demonstrate that the gamma radiation-induced graft copolymerization reaction of acrylamide onto PHB was successively achieved.<hr/>En el trabajo se realizó la síntesis del copolímero por injerto poli (3-hidroxibutirato)-g- poliacrilamida [P (HB-g-AAm)] por copolimerización de injerto radioinducido del monómero acrilamidaen el PHB. El estudio se llevó a cabo por el método de la irradiación simultánea. La estructura del copolímero se identificó por espectroscopía Infrarrojo por Transformada de Fourier (FTIR). Además, se realizó el estudio térmico del compuesto obtenido por análisis termogravimétrico (TGA) y calorimetría diferencial de barrido (DSC). De los resultados se encontraron señales (vibraciones de valencia -N-H) por FTIR que constituyen una importante evidencia de la reacción de injerto. El grado de injerto determinado por ATG fue de 10% y se detectaron cambios en los parámetros termodinámicos estudiados por DSC, que muestran una disminución de la cristalinidad y un aumento de la temperatura de transición vítrea. Los resultados demostraron la formación del copolímero por injerto inducido por radiaciones gamma. <![CDATA[x-ray detection system for digital image acquisition in the study of artworks]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2008000100002&lng=pt&nrm=iso&tlng=pt La radiografía de rayos-X juega un papel importante en el estudio de obras de arte, específicamente suministra información sobre la génesis, autenticidad, técnica de la pintura, condiciones del material e historia de su conservación. El trabajo muestra un sistema desarrollado, a partir de detectores semiconductores de microbandas para adquirir imágenes de rayos X basado en la técnica de substracción logarítmica del borde de absorción K. El sistema se caracterizó y se muestran las primeras imágenes de su aplicación en la detección de pigmentos.<hr/>X-ray radiography plays an important role in the study of artworks. It particularly provides information on the origin, authenticity, painting technique, material conditions and its conservation history. This article describes a system based on semiconductor microstrip detector for acquisition X-ray images using the k-edge logarithmic substraction technique. The system has been characterized and the first images of its application for pigment detection are shown. <![CDATA[Comparison of 131I activity measurements with radionuclide calibrators in nuclear medicine in cuba]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2008000100003&lng=pt&nrm=iso&tlng=pt Se presentan los resultados de la comparación nacional de la medición de actividad de 131I con activímetros, organizada en Cuba en el 2007. Estos resultados contribuyen a establecer la incertidumbre y la trazabilidad de los valores de actividad de 131I, determinados en los activímetros de las diferentes instituciones participantes: 9 hospitales y dos laboratorios del Centro de Isótopos que participaron directamente en la producción de los radiofármacos. Si consideramos solamente la proporción de resultados satisfactorios, el desempeño evidenciado por los participantes es igual al alcanzado en las comparaciones de este tipo, organizadas del 2002 al 2004 en el país. No obstante, la estimación razonable de la incertidumbre de la actividad de 131I medida en el activímetro, realizada por la mayoría de los participantes en el 2007, muestra un resultado cualitativamente superior con respecto al obtenido en el 2002-2004. Se reportaron los resultados del ejercicio bilateral de medición de 131I entre el Departamento de Metrología de Radionúclidos del Centro de Isótopos y el Laboratorio Nacional de Metrología de las Radiaciones Ionizantes del Instituto de Protección Radiológica y Dosimetría de Brasil. Concebido como complemento de la comparación nacional, este ejercicio bilateral proporciona evidencias adicionales de la comparabilidad de los patrones de medición utilizados para calibrar las disoluciones y muestras de referencia de 131I en el Departamento de Metrología de Radionúclidos del Centro de Isótopos.<hr/>Results from the national comparison of 131I activity measurements with radionuclide calibrators in Nuclear Medicine, organized in Cuba in 2007, are shown. These results contribute to establish the uncertainty and traceability of the 131I activity values measured with radionuclide calibrators of the participating institutions: 9 hospitals and two laboratories of the Isotope Centre directly involved in radiopharmaceuticals’ production. Concerning the proportion of acceptable results, no improvement was observed in the participants’ performance compared to results shown in such kind of exercises organized in the country during 2002-2004. On the other hand, the reasonable uncertainty estimate of the 131I measurements reported by most of the participants show a qualitatively superior outcome in 2007 compared to the result obtained in the previously organized exercises. Moreover, the outcome of the bilateral comparison for 131I activity measurements between the Radionuclide Metrology Department of the Isotope Centre (CENTIS-DMR) and the National Metrology Laboratory for Ionizing Radiation of the Brazilian Institute of Radiation Protection and Dosimetry (LNMRI-IRD) is also shown. This bilateral exercise provides additional evidences on comparability of the CENTIS-DMR measurement standards used to calibrate 131I reference solutions and samples. <![CDATA[Automated testing of microstripdetectors readout system for x-ray dual energy]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2008000100004&lng=pt&nrm=iso&tlng=pt Para la radiografía digital se requieren circuitos que realicen la recepción y procesamiento de señales nucleares de múltiples canales simultáneamente. Estos circuitos se deben someter a pruebas para caracterizar su funcionamiento. En este trabajo se describen pruebas automatizadas para controlar por software desde una computadora personal la caracterización de un sistema basado en circuitos integrados específicos del tipo RX64DTH con detectores de microbandas y se muestran los resultados.<hr/>Circuits that carry out the signal acquisition and processing by multiple channels are required in digital radiography. These circuits should be tested in order to characterize their performance. This paper describes an automated system to control (by a software, from a personal computer) the characterization of a system based on RX64DTH specific integrated circuits with microstrip detectors. The results are shown. <![CDATA[<strong>Intelligent interface for data acquisition and transmission from a neutron generator to a computer through an optical fibre</strong>]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2008000100005&lng=pt&nrm=iso&tlng=pt The present paper shows the design, construction and application of an interface developed on the base of the microcontroller usage. The aim is to reestablish the communication exchange among the basic modules that constitute the Neutron Generator belonging to the CEADEN Physics Department. Original interface design is upgraded by the automation of the data acquisition on the Neutron Generator exploitation parameters. The data acquisition card, optoelectronic converters, a PC-user interface using Lab VIEW environment, the indispensable firmware for interface functioning were developed for that purpose. The use of PC in the Neutron Generator is introduced, thus setting a precedent for the further automation of other subsystems.<hr/>Se presenta el diseño, construcción y aplicación de una interfase desarrollada utilizando microcontroladores, con el fin de restablecer la comunicación entre los módulos básicos que componen el generador de neutrones del Departamento de Física del Centro de Aplicaciones Tecnológicas y Desarrollo Nuclear. Se moderniza la interfase original automatizando la adquisición de la información sobre los parámetros de explotación del generador de neutrones. Se desarrolló la tarjeta de adquisición de las señales de interés, los conversores opto electrónicos, la interfase PC-usuario en ambiente LabView y los códigos indispensables para el funcionamiento de la interfase. Se introdujo el uso de la PC en el generador de neutrones y se estableció el antecedente para extender la automatización a otros subsistemas de la instalación. <![CDATA[Disassembly of a neutron irradiator]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2008000100006&lng=pt&nrm=iso&tlng=pt En el trabajo se describe el proceso de desmantelamiento de un irradiador neutrónico de 4,44·1011 Bq empleado en la radiomutagénesis vegetal. Se reporta el procedimiento desarrollado para dicho proceso. La importancia de estas experiencias está dada por tratarse de una instalación no estándar, atípica.<hr/>The disassembly of 4.44·1011 Bq neutron irradiator used in vegetable radio mutagenesis is described. The procedure developed for such purpose is reported. This irradiator is a non standard installation therefore, the disassembly experience is unique.