Scielo RSS <![CDATA[Nucleus]]> http://scielo.sld.cu/rss.php?pid=0864-084X20090001&lang=en vol. num. 45 lang. en <![CDATA[SciELO Logo]]> http://scielo.sld.cu/img/en/fbpelogp.gif http://scielo.sld.cu <![CDATA[Occupational and public exposures in RIT of brain tumors in Cuba]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2009000100001&lng=en&nrm=iso&tlng=en RESUMEN La primera fase del ensayo clínico del anticuerpo monoclonal humanizado h-R3 (Nimotuzumab) marcado con <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01014509.jpg">, para la radioinmunoterapia de tumores cerebrales malignos fue ejecutada durante el período 2002-2005 en Cuba. El objetivo del trabajo fue analizar los datos de la vigilancia radiológica realizada durante el estudio, con respecto a las dosis estimadas inicialmente. Estas últimas se calcularon para cada nivel de actividad, operación y cantidad total de pacientes, considerando el decaimiento radiactivo del <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01014509.jpg">y que una misma persona realizaba todas las operaciones. Se demostró que el riesgo radiológico de la práctica es aceptable. Las hipótesis conservadoras empleadas para los cálculos y el cumplimiento de los procedimientos de seguridad establecidos, determinaron que la exposición medida fuera inferior a la estimada. La realización de este trabajo constituye una referencia para la introducción y desarrollo de la radioinmunoterapia en Cuba.<hr/>ABSTRACT The first phase of the clinical trial using the humanized monoclonal antibody h-R3 (Nimotuzumab) labelled with <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01014509.jpg">, for radioimmunotherapy of brain malignant was performed during the period 2002-2005 in Cuba. The aim of this work was to analyze data from the radiological surveillance of this research compared to initially estimated doses. These latter were calculated for each activity level, operation and total quantity of patients, considering the radioactive decay of <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01014509.jpg">and taking into account that only one person carries out all of the operations. It was demonstrated that the radiation risk of the practice is acceptable. The conservative hypotheses for dose assessment and the compliance with established safety procedures during this trial showed that the measured exposure was lower than that estimated. This paper is a reference useful to introduce and develop the RIT in Cuba. <![CDATA[Characterization of <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01024509.jpg">- macroaggregates formulation]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2009000100002&lng=en&nrm=iso&tlng=en RESUMEN En este trabajo se realizó la caracterización del proceso de formación y marcaje de los macroagregados de albúmina (MAA) con <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01024509.jpg">. Con este fin se efectuaron estudios comparativos para establecer el papel de la desnaturalización en presencia del <img width=30 height=13 src="http:/img/revistas/nuc/n45/e02024509.jpg">durante la formulación de <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01024509.jpg">-Sn-MAA, para ello se utilizaron tres formulaciones. Se realizó un análisis estructural cualitativo de la albúmina sérica humana para describir el sistema a través de un modelo gráfico. Los resultados mostraron diferencias importantes en el comportamiento radioquímico de las tres formulaciones. La formulación de <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01024509.jpg">-Sn-MAA (A) mostró un comportamiento superior, con purezas radioquímicas cercanas a 95% en los tiempos estudiados y una disociación inferior al 20% en 24 h.El modelo gráfico permitió explicar, a través de sencillas representaciones, los procesos involucrados en el sistema estudiado, permitiendo una mejor comprensión de este.<hr/>ABSTRACT The aim of this paper was to study the formation and radiolabelling of 99m Tcalbumin macroaggregates. Comparatives studies of three formulations to establish the role of denaturalization and <img width=30 height=13 src="http:/img/revistas/nuc/n45/e02024509.jpg">in the formulation of <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01024509.jpg">-Sn-MAA were carried out. A qualitative structural analysis of human serum albumin was performed in order to give a description of the studied system using a graph model. The results showed important differences in the radiochemical behavior of the three formulations. <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01024509.jpg">-Sn-MAA (A) formulation had the best behavior, with radiochemical purity close to 95% and dissociation below 20% after 24 h of being radiolabeled. The graph model explained with simple representations the process involved in the studied system;thus allowing a better knowledge of it. <![CDATA[Preparation of <img width=30 height=13 src="http:/img/revistas/nuc/n45/e01034509.jpg">-macroaggregated albumin for lung perfusion studies]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2009000100003&lng=en&nrm=iso&tlng=en RESUMEN En este trabajo, se realizó el diseño, optimización, control de calidad de pureza radioquímica, cualidad biológica y estudios de estabilidad en el tiempo de una formulación de macroagregados de albúmina a partir de la desnaturalización controlada de la ASH. Se realizó un diseño experimental con un plan factorial <img width=30 height=13 src="http:/img/revistas/nuc/n45/e06034509.jpg">para determinar las condiciones ideales de la formulación. Los resultados mostraron que la concentración de albúmina en el intervalo 515 mg/mL es irrelevante, sin embargo, el pH final de la mezcla y la velocidad de agitación sí fueron relevantes, así como todas las variables de interacción. Con las condiciones seleccionadas en el diseño experimental, se obtuvieron formulaciones con tamaño de partículas con diámetros comprendidos entre 11 y 80 µ, que cumplieron los criterios de pureza radioquímica establecidos internacionalmente, así como la condición de esterilidad y apirogenicidad. La biodistribución en animales de experimentación mostró imágenes pulmonares de buena calidad. Los lotes producidos mantuvieron estabilidad física, radioquímica, biológica y microbiológica durante 90 días de conservación a 4°C.<hr/>ABSTRACT The present paper shows the design, optimization, quality control for testing radiochemical purity, biological quality and realtime stability studies of a preparation of macroaggregated albumin from the controlled denaturation of HSA. An experimental design with a <img width=30 height=13 src="http:/img/revistas/nuc/n45/e06034509.jpg">factorial plan was carried out in order to determine the ideal conditions for the preparation. The results showed that variations of albumin concentrations within the range of 515 mg/mL were irrelevant, however, the final pH of the mixture and the stirring speed were significant variables, as well as their interaction. Formulations with particles of diameter between 11 and 80 µ were obtained with the conditions selected in the experimental design which met the internationally established criteria for radiochemical purity, sterility and apyrogenicity. The biodistribution in experimental animals showed good quality lung images. The produced lots maintained physical, radiochemical, biological and microbiological stability during 90 days of storage at 4°C. <![CDATA[<strong>Experimental and Monte Carlo determination of mass absorption coefficients for </strong><b><img width=30 height=13 src="http:/img/revistas/nuc/n45/e03044509.jpg"></b><strong>/ </strong><b><img width=30 height=13 src="http:/img/revistas/nuc/n45/e02044509.jpg"></b><strong>beta particles in organic compounds</strong>]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2009000100004&lng=en&nrm=iso&tlng=en ABSTRACT In order to investigate the bparticles absorption in organic compounds, an experimental arrangement was designed. A Monte Carlo transport code was also used to simulate this process. This allowed reporting for the first time m (<img width=30 height=13 src="http:/img/revistas/nuc/n45/e02044509.jpg">) values in several organic compounds for <img width=30 height=13 src="http:/img/revistas/nuc/n45/e03044509.jpg">/ <img width=30 height=13 src="http:/img/revistas/nuc/n45/e02044509.jpg">isotopic sources. The obtained experimental and calculated values showed a good concordance. Methodological aspects of the µ (<img width=30 height=13 src="http:/img/revistas/nuc/n45/e02044509.jpg">) determination concerning the range of the absorber’s superficial density are discussed.<hr/>RESUMEN Se estudia la absorción de partículas beta en compuestos orgánicos en una instalación diseñada al efecto. El proceso de absorción es además simulado mediante el código de Monte Carlo. Se reportan, por primera vez, los coeficientes de absorción másicos para partículas beta de <img width=30 height=13 src="http:/img/revistas/nuc/n45/e03044509.jpg">/ <img width=30 height=13 src="http:/img/revistas/nuc/n45/e02044509.jpg">en varios compuestos orgánicos. Se obtiene una buena correspondencia entre los resultados experimentales y los simulados. Se discuten aspectos metodológicos de la determinación del coeficiente de absorción másico, relacionado con el intervalo de densidad de absorción superficial. <![CDATA[<strong>Radiation damage study in CZT matrix detectors exposed to gamma rays</strong>]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2009000100005&lng=en&nrm=iso&tlng=en RESUMEN El daño radiacional en términos de desplazamientos atómicos en un típico detector de CZT empleado en aplicaciones de imagenología médica fue estudiado utilizando el método estadístico de Monte Carlo. Se tuvieron en cuenta todas las características estructurales y geométricas del detector, así como las diferentes energías de los fotones usualmente empleados en la aplicación. Considerando la aproximación clásica de Mott-McKinley-Feshbach se calcularon las secciones eficaces de desplazamiento, así como el número de desplazamientos por átomo para cada especie atómica presente en el material y para cada energía considerada de los fotones. Estos resultados se analizan y comparan entre sí y finalmente se establece la comparación entre el daño radiacional que tiene lugar en el detector de CZT con el que se manifiesta en un detector similar, pero fabricado con otros materiales semiconductores.<hr/>ABSTRACT Radiation damage in terms of atomic displacements in a typical CZT detector used in medical imaging applications was studied using the Monte Carlo statistical method. All detector structural and geometric features as well as different energies of the photons usually used in the application were taken into account. Considering the Mott-McKinley-Feshbach classical approach, effective cross sections of the displacements were calculated, including the number of displacements per atom for each atomic species present in the material and each photon energy considered. These results are analyzed and compared. Finally, the radiation damage on CZT detector is compared to that calculated in a similar detector manufactured with other semiconducting materials. <![CDATA[<strong>Uranium Enrichment Determination of the InSTEC Sub Critical Ensemble Fuel by Gamma Spectrometry</strong>]]> http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-084X2009000100006&lng=en&nrm=iso&tlng=en ABSTRACT Lowbackground gamma spectrometry was applied to analyze the uranium enrichment of the nuclear fuel used in the InSTEC Sub Critical ensemble. The enrichment was calculated by two variants: an absolute method using the Monte Carlo method to simulated detector volumetric efficiency, and an iterative procedure without using standard sources. The results confirm that the nuclear fuel of the ensemble is natural uranium without any additional degree of enrichment.<hr/>RESUMEN Se analiza el grado de enriquecimiento del uranio del combustible nuclear usado en el Conjunto Subcrítico del InSTEC mediante espectrometría gamma de bajo fondo. El enriquecimiento se calcula tanto por vía absoluta, simulando la eficiencia del detector por Monte Carlo, como por un procedimiento iterativo que no requiere del empleo de muestras estándares. Los resultados confirman que el combustible nuclear es uranio natural sin ningún grado de enriquecimiento adicional.