Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/translation.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36
Accionamiento de un ventilador industrial para prueba de aerogeneradores


 
35 3 
Home Page  

  • SciELO

  • SciELO


Ingeniería Energética

 ISSN 1815-5901

LOPEZ MONTEAGUDO, Francisco E. et al. Drive of an industrial fan for wind testing. []. , 35, 3, pp. 242-251. ISSN 1815-5901.

In this work, a fan control industrial wind turbines used for test, which is used as an internal device in the development of a wind tunnel for testing wind measurement. The project consists of regulating the speed of an industrial fan used in a wind tunnel to test control systems in wind turbines, wind generating regulated signals in constant, or to follow a profile defined by a database of values actual measured with an anemometer. To implement the control system and communication devices, in this project employed a digital signal processor (DSP from Texas Instruments EZDSP2407), which acts as an interface to transmit data between the programming environments (VisSim Embedded Control Developer (ECD)). Also uses a variable speed 3HP SIEMENS Micromaster model 420

: air turbines; fan control; wind power; wind tunnel; fan.

        · |     · |     · ( pdf )