SciELO - Scientific Electronic Library Online

 
vol.50 número1Hipnosis como complemento en la cirugía oral del adulto mayorPropuesta de teorías integradoras para la cefalogénesis y sus malformaciones índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista Cubana de Estomatología

versión impresa ISSN 0034-7507

Resumen

CORREA VELEZ, Santiago; FELIPE ISAZA, Juan; SOL GAVIRIA, Ana  y  NARANJO, Mauricio. Resistance of teeth restored with prefabricated posts to maximum intercuspidation loads, mastication and bruxism. Rev Cubana Estomatol [online]. 2013, vol.50, n.1, pp. 53-69. ISSN 0034-7507.

Objective: using the finite element method, determine the resistance of teeth restored with prefabricated posts to maximum static intercuspidation loads, cyclical mastication loads and bruxism, and analyze the effect of periodontal loss on resistance by restorations. Methods: using the finite element method, an in vitro study was conducted of teeth with periodontal loss rehabilitated with prefabricated glass fiber, carbon and titanium posts. Reconstruction of the teeth was based on tomographic images from a periodontically healthy patient. Results: it was shown that rehabilitations did not tend to yield to static loads, irrespective of post material or the degree of periodontal loss. For bruxism and 4 mm periodontal loss, dentin durability was 60 000 cycles, irrespective of post material. For mastication loads and a healthy periodont, dentin failure occurs at 100 000 cycles with titanium posts, 200 000 cycles with carbon fiber posts, and 1 100 000 cycles with glass fiber posts. For 2 mm periodontal loss, dentin durability decreased to 4 000 cycles with titanium posts, 5 000 cycles with carbon fiber posts, and 7 000 cycles with glass fiber posts. For 4 mm periodontal loss, dentin durability is estimated at 1 000 cycles, irrespective of post material. Conclusions: restorations with glass fiber, carbon and titanium prefabricated posts do not yield to maximum static intercuspidation loads, irrespective of the degree of periodontal loss. Prefabricated posts exhibit endless resistance to cyclic loads. Dentin is the structure most severely affected by such events.

Palabras clave : posts; finite element analysis; bruxism; cyclic load; alveolar bone loss.

        · resumen en Español     · texto en Español     · Español ( pdf )