Ingeniería Energética
versión On-line ISSN 1815-5901
Resumen
DIAZ ROLLER, Yenisel et al. Influence of the electromagnetic interference on the electroaudiometric signal of the AUDIX V. Energética [online]. 2022, vol.43, n.2, pp. 27-35. Epub 11-Jul-2022. ISSN 1815-5901.
The electrical network is one of the least detected sources of electromagnetic interference, but it causes adverse effects on the medical equipment that is in its radius of action. The objective of this work is to analyze the effect of the magnetic field on the signal emitted by the Audix V equipment. A magnetic field generator, a gaussmeter, a signal simulator and an Audix equipment were transmitted. The research was carried out, following a methodology developed from different methods found in the literature. Screenshots of the signals emitted by the Audix V with visible influence on the parameters that characterize it were obtained by applying field values even below the 3.77 µT allowed by the IEC. It was concluded that there may be an error in the diagnosis due to the deformation caused by the electromagnetic field on the characteristics of the signal.
Palabras clave : Audix V equipment; Electromagnetic fields, electroaudiometric signal, interference.