SciELO - Scientific Electronic Library Online

 
vol.36 número3Frecuencia de aberraciones moleculares en pacientes cubanos con leucemia mieloide agudaPrograma de superación profesional en medicina transfusional para la especialidad Anestesiología y Reanimación índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista Cubana de Hematología, Inmunología y Hemoterapia

versión On-line ISSN 1561-2996

Resumen

ZUNIGA ROSALES, Yaíma; VILLEGAS VALVERDE, Carlos Agustín; TORRES RIVES, Bárbara  y  HERNANDEZ REYES, Evelyn. Design and optimization of a polychromatic tube of flow cytometry for peripheral lymphocyte immunophenotype. Rev Cubana Hematol Inmunol Hemoter [online]. 2020, vol.36, n.3  Epub 01-Feb-2021. ISSN 1561-2996.

Introduction:

Flow cytometry allows quantification of lymphocyte subpopulations with high sensitivity, specificity and objectivity. These advantages are only achieved through the hardworking process of individualized and controlled design for each experiment.

Objective:

To design a flow cytometry protocol of a single polychromatic tube for peripheral lymphocyte immunophenotype.

Methods:

An experimental in vitro study was carried out, in March 2019, with peripheral blood samples obtained from three healthy volunteers, at the National Center for Medical Genetics. The tube was made up of six lineage markers for identifying natural B and T lymphocytes, natural killers and natural killer T cells. A protocol was developed for red blood cell lysis without washing. Fluorochrome-conjugated monoclonal antibodies were used. The optimal point of concentration corresponded to the highest staining index and preservation of the positivity percentages of each population. Progressive tube construction was performed and a logical window sequence strategy was proposed for data analysis.

Results:

The chosen markers allowed to carry out correct peripheral lymphocyte immunophenotype. Good discriminations between positive and negative signals were observed at the five titration points, except for anti-CD56, which presented a decreasing trend in the staining index. The total volume of conjugates required for determination of the six antigens was 3.75 μL per tube.

Conclusions:

A polychromatic tube was obtained that allows to carry out peripheral immunophenotype quickly and precisely by six lymphocyte antigens simultaneously, with the use of small volumes of conjugate and blood.

Palabras clave : flow cytometry; lymphocyte subgroups; T lymphocytes; B lymphocytes; natural killers; peripheral lymphocyte immunophenotype.

        · resumen en Español     · texto en Español     · Español ( pdf )