vol.47 número1Método RP- HPLC validado para la determinación de residuos de Irinotecan Hidrocloruro para la validación de la limpieza en el área de producciónMedidas de bioseguridad adoptadas en el manejo con materiales biológicos en Laboratorios Liorad índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Revista Cubana de Farmacia

versão impressa ISSN 0034-7515

Resumo

MARTINEZ ALVAREZ, Luis Octavio; MENA SALABARRIA, Keila  e  CESPEDES PEREZ, Mirelys. Chemical compatibility of piracetam determined by differential scanning calorimetry. Rev Cubana Farm [online]. 2013, vol.47, n.1, pp. 51-56. ISSN 0034-7515.

Introduction: the first phase of the drug preformulation comprises the selection of excipients and the conduction of studies on chemical compatibility between pharmacologically active ingredient and the excipients. One of the quickest techniques is the differential scanning calorimetry and the supplementary technique called thermogravimetic analysis. Objective: to conduct a chemical compatibility study of the pharmacologically active ingredient and of the preselected excipients by using differential scanning calorimentry (DSC) and thermogravimetric analysis (TG), in order to confirm the chemical interaction between them. Methods: this study used the thermal analysis equipment TA 3000 Mettler, coupled with the DSC 20 cell and the TG50 oven. The pharmacologically active ingredient was Piracetam and the excipients were Aerosil Kollidon VA64, magnesium stearate, microcrystalline cellulose, Polyethylene glycol 20 000. The differential scanning calorimetry characterized the excipients and the pharmacologically active ingredient as well, whose physical fusion transition was determined. Some binary physical mixtures with a concentration ratio of 1:1 were prepared to study compatibility. Results: figure 1 showed the pharmacologically active ingredient´s fusion point detection. Two endothermal transitions were determined as well as the fusion transition by the TG equipment. Figure 2 showed the thermograms of mixtures between pharmacologically active ingredient and excipients. Conclusions: the occurrence of new peaks was bit detected, so it was inferred from this study that there was no chemical incompatibility between the studied substances, and the excipients are recommended for the development of the final pharmaceutical formulation.

Palavras-chave : differential scanning calorimetry; incompatibility chemistry; physical mixtures binary; Piracetam.