SciELO - Scientific Electronic Library Online

 
vol.48 número1VERIFICACIÓN DE UNA TÉCNICA POR CROMATOGRAFÍA LÍQUIDA DE ALTA RESOLUCIÓN PARA CUANTIFICAR FIPRONILO EN UNA FORMULACIÓN EN CEBOS índice de autoresíndice de assuntospesquisa de artigos
Home Pagelista alfabética de periódicos  

Serviços Personalizados

Artigo

Indicadores

  • Não possue artigos citadosCitado por SciELO

Links relacionados

  • Não possue artigos similaresSimilares em SciELO

Compartilhar


Centro Azúcar

versão On-line ISSN 2223-4861

Resumo

CABRERA ESTRADA, Isabel; ARBONA CABRERA, Mercedes; GARCIA HERNANDEZ, María de los Ángeles  e  GONZALEZ CORTES, Elizabeth. BIOLOGICAL NUTRIENT APPLICATION FOR WASTEWATER TREATMENT IN TEXTIL INDUSTRY “DESEMBARCO DEL GRANMA” EVALUATION. cen. az. [online]. 2021, vol.48, n.1, pp. 1-12.  Epub 01-Jan-2021. ISSN 2223-4861.

Introduction:

“Desembarco del Granma” textile factory has a liquid waste treatment system using activated sludge. Fluctuations in these waters flow cause an organic loads deficit. It is necessary to meet microorganism’s nutritional needs in process.

Objective:

To evaluate the feasibility of applying CENTERFOOD XL to improve wastewater treatment system in the textile factory "Desembarco del Granma".

Materials and methods:

CENTERFOOD XL (1 g/L of wastewater) (COLORCENTER CENTERFOOD XL, 2016) was used as nutrient for wastewater from the textile factory. The treatment effectiveness was evaluated by the suspended volatile solids (SSV). Results were processed with Statgraphics software.

Results and Discussion:

Dependence between SSV with nutrient concentration, time and production plants working was obtained. After 15 days without working production plants, SSV are 1712.8 and 3068.25 mg/L without and with nutrients addition respectively. The investment is $ 51253.58. Receiving bodies contamination decreases, effluent Chemical Oxygen Demand (COD) values comply with the established in (NC 27, 2012).

Conclusions:

One gram of CENTERFOOD XL should be added per residual water liter of, in treatment plant, if there are breaks superior to fifteen days, and SSV are above 3000 mg/L. Flow system investment cost is $ 51253.58. Nutrient supply every fifteen days is 1200.19 kg and it costs $ 3360.54.

Palavras-chave : textile industry; activated sludge; biological nutrient.

        · resumo em Espanhol     · texto em Espanhol     · Espanhol ( pdf )