SciELO - Scientific Electronic Library Online

 
vol.46 número1Evaluación reológica de dos polímeros derivados de la polivinilpirrolidona para uso oftálmicoComparación entre dos biomodelos murinos (ratones Balb/c y ratas Sprague Dawley) en el ensayo de micronúcleos transplacentarios índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista Cubana de Farmacia

versión impresa ISSN 0034-7515

Resumen

BAEZA FONTE, Alen Nils; DIAZ AGUILA, Elsa Eneida  y  MARTINEZ ALFONSO, Nancy. Quantification of glibenclamide in cleaning samples of pharmaceutical equipment through high performance liquid chromatography. Rev Cubana Farm [online]. 2012, vol.46, n.1, pp.29-39. ISSN 0034-7515.

Objective: to submit a selective analytical method for quantization of glibenclamide in cleaning samples of pharmaceutical equipment using high performance liquid chromatography. Methods: the mobile phase consisted of an equal mixing of acetonitrile/phosphate buffer KH2PO4; with 0.037 mol/L concentration pH 5.25 and flow of 1.5 mL/min, in a Nucleosil 100 C8 column. Glibenclamide was injected with progesterone as internal standard and using an UV detector= 230 nm Results: the method was linear in the 0.4-150 mg/mL concentration interval having a detection and quantization limits of 10 and 40 ng/mL respectively. It was specific to analyte when placebo is present, to degradation products and to other active ingredients. Possible interferences with the proposed method was considered for captopril, chlortalidone, dexametasone, diphenhydramin HCl, digoxine, 8-chlortheophylline, diphenhydramina HCl, phenobarbital, haloperidol, hydrochlorothiazide, fumaric acid, ketotifen, metoclopramide HCl, piridoxine HCl, piroxicam, prednisone and nifedipine, On the other hand, ibuprofen, indometacin, trifluoperazine HCl, thioridazine HCl and imipramine were identified as interferences in the procedure at concentration figures close to 10 mg/mL. Conclusions: the present method is sensitive, quick and selective for the evaluation of residues of active pharmaceutical principle glibenclamide in tablet production equipment after a swap sampling and it could be potentially used in case of cross-contamination of glibenclamide and other drugs already described.

Palabras clave : glibenclamide; glyburide; high performance liquid chromatography; validation; cleaning validation; traces; detection limit; quantization limit.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons