SciELO - Scientific Electronic Library Online

 
vol.39 número1Marcadores moleculares para la taxonomía e identificación del género Brucella (Alphaproteobacteria)Incidencia del sexo, el índice de masa corporal y el número de hermanos en la competencia motriz autopercibida índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Revista Cubana de Investigaciones Biomédicas

versión impresa ISSN 0864-0300versión On-line ISSN 1561-3011

Resumen

CHAPLE GIL, Alain Manuel; QUINTANA MUNOZ, Lisandra; FERNANDEZ GODOY, Eduardo  y  CUESTA NOA, Marisel de la Caridad. Assessment the accuracy of electronic apex locater in single canal teeth. Rev Cubana Invest Bioméd [online]. 2020, vol.39, n.1, e385.  Epub 01-Mar-2020. ISSN 0864-0300.

Introduction:

The correct determination of working length is one of the main determining factors for the success of endodontic treatments. Objective: to assess the accuracy when determining the working length of an electronic apex locator.

Objective:

To assess the accuracy of the determination of the working length of an electronic apex locator in monoradicular teeth.

Material and methods:

An exploratory experimental study was carried out in vivo where the working length was taken in 141 monoradicular root canals of patients with indication of extraction. Working length was determined using iPex II electronic apex locator (NSK). When the locator marked that the file was at the apex, without removing the instrument from the duct, it was fixed. The extraction was performed with caution and subsequently a proximal wall of the apical third was worn down until the file was observed inside the duct, observed and studied with the help of a magnifying glass. The working length was acceptable when the locator determined that it was between 0.5-1.5 mm of the cement-dentin-duct limit; short when it was more than 1.5 mm and long when it was observed that it exceeded the cement-dentine-duct limit.

Results:

The accuracy of 95.7 % (135) of the measurements was acceptable and only 13(9.2 %) ducts had instability, with an existing relationship between the accuracy and instability of the measurements. It was observed that 88(62.4 %) ducts with secretions obtained an acceptable one in the determination of the length of work. Only 3 (2.1 %) ducts with secretions had short measurements. The presence of secretions was not significant to assess the accuracy.

Conclusions:

The measurements of the working lengths using the locator studied were, almost entirely, of acceptable precision and were practically unstable. Similarly, the presence of secretions inside the root canals did not significantly affect the accuracy of the localizer in question.

Palabras clave : endodontics; tooth apex; precision medicine; technology assessment, biomedical; evaluation studies.

        · resumen en Español     · texto en Español     · Español ( pdf )