Mi SciELO
Servicios Personalizados
Articulo
Indicadores
- Citado por SciELO
Links relacionados
- Similares en SciELO
Compartir
Nucleus
versión On-line ISSN 2075-5635
Resumen
LINARES ROSALES, Haydee M; LARA MAS, Elier y ALFONSO LAGUARDIA, Rodolfo. Application of an Elekta Precise lineal accelerator model based on Monte Carlo to evaluate the solid state detectors response. Nucleus [online]. 2015, n.57, pp. 13-18. ISSN 2075-5635.
The evaluation of the solid state detectors response based on a Monte Carlo model of an Elekta Precise lineal accelerator, was done in this work for the beam energies of 6 y 15 MV. Simulations were performed using the EGSnrc code. Employing the optimal values of mean energy and FWHM from the primary electron beam, deposited dose in a voxelized water phantom at 100 cm of source to surface distance was calculated. Depth dose curves and lateral dose profi les were obtained. Comparison between simulations and the experimental values obtained for each detector, were done using acceptability criteria based on confi dence limits. Additionally outputs factors were analyzed in each one of the study cases. Good agreement between simulations and measurements were reached
Palabras clave : Monte Carlo method; dosimetry; radiation detectors; radiation dose distributions.