SciELO - Scientific Electronic Library Online

 
 número59Monitoreo dinámico de riesgo empleando matriz de riesgo en prácticas médicas con radiaciones ionizantes índice de autoresíndice de materiabúsqueda de artículos
Home Pagelista alfabética de revistas  

Servicios Personalizados

Revista

Articulo

Indicadores

  • No hay articulos citadosCitado por SciELO

Links relacionados

  • No hay articulos similaresSimilares en SciELO

Compartir


Nucleus

versión impresa ISSN 0864-084Xversión On-line ISSN 2075-5635

Resumen

RAMOS MACHADO, Dayana; YERA SIMANCA, Yoan; LOPEZ BEJERANO, Gladys Mercedes  y  ACOSTA RODRIGUEZ, Nancy. Determination of the detection efficiency of Descripción: Descripción: D:\Scielo\Nucleus html\n 59\img\e01085916.jpgin thiroid using Monte Carlo method. Nucleus [online]. 2016, n.59, pp.34-40. ISSN 0864-084X.

Monte Carlo Method was the base to estimate the detection efficiency of of the identiFINDER ultra detector in “thyroid” geometry. The suitability of the calibration methodology is discussed using a comparison of the results of the Direct Monte Carlo Method and the Transfer Monte Carlo Method calculations with the values of experimentally calculated efficiency. Transfer Monte Carlo Method was the elected methodology because of the differences with the real detection efficiency stay below 10 %. In the simulations, the geometric parameters of the detector were found using a tomography study. The arrangement detector – point source was simulated to obtain the correction factors for preset distances, and the arrangement detector – thyroid phantom was simulated to obtain the detection efficiency curve in function of the distance for . In order to validate the proposed methodology the Internal Dosimetry Laboratory of the Centre for Radiation Protection and Hygiene participated in a regional intercomparison exercise of measured activity estimation in thyroid, for the estimation were used the traditional calculation methodology as well as the methodology base on Monte Carlo Method, the results were satisfactory in both cases. As a final result, the curves of detection efficiency for the measurement of in the thyroid gland was obtained without using physical phantoms, replacing the current lack of it

Palabras clave : eficiencia; método de monte carlo; yodo; tiroides; espectrómetros gamma; detección; efficiency; monte carlo method; iodine; thyroid; gamma spectrometers; detection.

        · resumen en Español     · texto en Español     · Español ( pdf )

 

Creative Commons License Todo el contenido de esta revista, excepto dónde está identificado, está bajo una Licencia Creative Commons