Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/translation.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36

Warning: XSLTProcessor::transformToXml() [xsltprocessor.transformtoxml]: I/O warning : failed to load external entity "/srv-new/scielo/www/htdocs/xml/e/language.xml" in /srv-new/scielo/www/htdocs/class.XSLTransformerPHP5.php on line 36
Estimación de la incertidumbre en la medición del contenido de furvina en el Vitrofural®


 
35 1 
Home Page  

  • SciELO

  • SciELO


Revista Cubana de Química

 ISSN 2224-5421

QUINONES-GARCIA, Yaidel; CARABALLOSO-NOA, Isabel; CALVO-ALONSO, Amalia    TORRE-LOPEZ, Jorge de la. Uncertainty estimation in the measurement of furvina content in Vitrofural®. []. , 35, 1, pp. 14-28.   17--2023. ISSN 2224-5421.

All results of analytical measurements have a degree of uncertainty, which is related to the steps carried out and the materials and/or equipment used in the method. The objective of this work was to estimate the uncertainty in the measurement of the Furvina content in Vitrofural by ultraviolet - visible spectrophotometry, through the GUM approach. The mathematical model was obtained and the sources of uncertainty were identified with a cause-effect diagram. Uncertainty components were evaluated and the combined uncertainty value (0,06 %) was obtained. The greatest contributions to uncertainty correspond to glassware used. The expanded uncertainty (0,12 %) was calculated and the Furvina content was determined in a batch of Vitrofural: the final result was 30,21 % ± 0,12 %, k = 2.

: uncertainty; Vitrofural; furvina; ultraviolet-visible spectrophotometry..

        · |     · |     · ( pdf )