<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-2176</journal-id>
<journal-title><![CDATA[Revista Cubana de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Oftalmol]]></abbrev-journal-title>
<issn>0864-2176</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-21762010000200002</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Resultados visuales en pacientes operados de catarata con lente intraocular multifocal modelo OcuFlex]]></article-title>
<article-title xml:lang="en"><![CDATA[Visual results achieved in patients operated on from cataract with the use of OcuFlex multifocal intraocular lenses]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez Candelaria]]></surname>
<given-names><![CDATA[Eneida]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cárdenas Díaz]]></surname>
<given-names><![CDATA[Taimí]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Capote Cabrera]]></surname>
<given-names><![CDATA[Armando]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Méndez Duque de Estrada]]></surname>
<given-names><![CDATA[Ana]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cuan Aguilar]]></surname>
<given-names><![CDATA[Yoriel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Cubano de Oftalmología Ramón Pando Ferrer  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2010</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2010</year>
</pub-date>
<volume>23</volume>
<numero>2</numero>
<fpage>185</fpage>
<lpage>195</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762010000200002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-21762010000200002&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-21762010000200002&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[OBJETIVO: Describir los resultados visuales en 8 pacientes operados de catarata bilateral con la técnica de Faco-chop e implante de lente intraocular multifocal modelo OcuFlex, en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", desde septiembre del 2007 a febrero del 2008. MÉTODOS: Se realizó un estudio observacional, descriptivo, longitudinal y prospectivo donde se analizaron variables como: edad, sexo, agudeza visual sin corrección y la mejor agudeza visual corregida a diferentes distancias. Se utilizó la estadística descriptiva en el análisis de los datos con ayuda del sistema Microsoft Excel y Word 2003, para Windows XP. RESULTADOS: Se encontró que la edad media fue de 68,5 años. La agudeza visual media para lejos preoperatoria y posoperatoria, monocular y espontánea (sin corrección) fue de 0,17 y 0,8, respectivamente y la agudeza visual corregida fue de 0,41 y 0,98. En el posoperatorio se encontró que el 93,75 % de los casos alcanzaban en visión monocular espontánea un J3 o mejor como agudeza visual Intermedia y un J1 de cerca. CONCLUSIONES: Los lentes multifocales disminuyen la dependencia de las gafas después de la cirugía de catarata, lo que constituye una buena opción en la recuperación de la función visual óptima.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[OBJECTIVE: To describe the visual results of 8 patients operated on from bilateral cataract using Phaco-chop technique and implantation of OcuFlex multifocal intraocular lens at "Ramón Pando Ferrer" Cuban Institute of Ophthalmology from September 2007 to February 2008. METHODS: A prospective, longitudinal, observational and descriptive study was conducted to analyze variables such as age, sex, visual acuity without correction and best corrected acuity at different focal distances. Summary measures were used in analyzing data, with the support of Microsoft Excel and Word 2003 system for Windows XP. RESULTS: It was found that average age was 68.5 years. The average visual acuity for far distances before and after surgery, monocular and spontaneous (without correction) was 0.17 and 0.8 respectively whereas corrected visual acuity was 0.41 and 0.98 respectively. At the postoperative phase, the spontaneous monocular vision in 93.75 % of patients reached J3 or better as intermediate visual acuity and J1 as near visual acuity. CONCLUSIONS: The multifocal lenses reduce the dependency on glasses after cataract surgery, which is a good choice for the recovery of optimal vision.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Catarata]]></kwd>
<kwd lng="es"><![CDATA[cirugía]]></kwd>
<kwd lng="es"><![CDATA[lente multifocal]]></kwd>
<kwd lng="en"><![CDATA[cataract]]></kwd>
<kwd lng="en"><![CDATA[surgery]]></kwd>
<kwd lng="en"><![CDATA[multifocal lens]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <P ALIGN="RIGHT"><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>INVESTIGACIONES</B></FONT></P>    <P>&nbsp;</P>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="4"><B>Resultados  visuales en pacientes operados de catarata con lente intraocular multifocal modelo  OcuFlex</B></FONT></P>    <P>&nbsp;</P>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="3"><B>Visual  results achieved in patients operated on from cataract with the use of OcuFlex  multifocal intraocular lenses</B></FONT></P><B>    <P>    <P>    <P>     <P>      <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Eneida P&eacute;rez    Candelaria<SUP>I</SUP>; Taim&iacute; C&aacute;rdenas D&iacute;az<SUP>II</SUP>;    Armando Capote Cabrera<SUP>III</SUP>; Ana M&eacute;ndez Duque de Estrada<SUP>IV</SUP>;    Yoriel Cuan Aguilar<SUP>V</SUP></FONT> </B>     ]]></body>
<body><![CDATA[<P>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><SUP>I  </SUP>Especialista de II Grado en Oftalmolog&iacute;a. Profesora Auxiliar. Instituto  Cubano de Oftalmolog&iacute;a &quot;Ram&oacute;n Pando Ferrer&quot;. La Habana,  Cuba.    <BR></FONT><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><SUP>II  </SUP>Especialista de I Grado en Oftalmolog&iacute;a. Especialista de I Grado  en MGI. Profesor Instructor. M&aacute;ster en Enfermedades Infecciosas. Instituto  Cubano de Oftalmolog&iacute;a &quot;Ram&oacute;n Pando Ferrer&quot;. La Habana,  Cuba.    <BR></FONT><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><SUP>III  </SUP>Especialista de I Grado en Oftalmolog&iacute;a. Profesor Auxiliar. Instituto  Cubano de Oftalmolog&iacute;a &quot;Ram&oacute;n Pando Ferrer&quot;. La Habana,  Cuba.    <BR></FONT><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><SUP>IV  </SUP>Especialista de I Grado en Oftalmolog&iacute;a. Profesora Asistente. Instituto  Cubano de Oftalmolog&iacute;a &quot;Ram&oacute;n Pando Ferrer&quot;. La Habana,  Cuba.    <BR></FONT><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><SUP>V  </SUP>Especialista de I Grado en Oftalmolog&iacute;a. Especialista de I Grado  en Medicina General Integral. Instituto Cubano de Oftalmolog&iacute;a &quot;Ram&oacute;n  Pando Ferrer&quot;. La Habana, Cuba.</FONT>    <P>    <P>    <P><hr size="1" noshade>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>RESUMEN  </B></FONT></P>     ]]></body>
<body><![CDATA[<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>OBJETIVO:</B>    Describir los resultados visuales en 8 pacientes operados de catarata bilateral    con la t&eacute;cnica de Faco-chop e implante de lente intraocular multifocal    modelo OcuFlex, en el Instituto Cubano de Oftalmolog&iacute;a &quot;Ram&oacute;n    Pando Ferrer&quot;, desde septiembre del 2007 a febrero del 2008.    <BR>   <B>M&Eacute;TODOS:</B> Se realiz&oacute; un estudio observacional, descriptivo,    longitudinal y prospectivo donde se analizaron variables como: edad, sexo, agudeza    visual sin correcci&oacute;n y la mejor agudeza visual corregida a diferentes    distancias. Se utiliz&oacute; la estad&iacute;stica descriptiva en el an&aacute;lisis    de los datos con ayuda del sistema Microsoft Excel y Word 2003, para Windows    XP.    <BR>   <B>RESULTADOS:</B> Se encontr&oacute; que la edad media fue de 68,5 a&ntilde;os.    La agudeza visual media para lejos preoperatoria y posoperatoria, monocular    y espont&aacute;nea (sin correcci&oacute;n) fue de 0,17 y 0,8, respectivamente    y la agudeza visual corregida fue de 0,41 y 0,98. En el posoperatorio se encontr&oacute;    que el 93,75 % de los casos alcanzaban en visi&oacute;n monocular espont&aacute;nea    un J3 o mejor como agudeza visual Intermedia y un J1 de cerca.    <BR>   </FONT><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>CONCLUSIONES:</B>    Los lentes multifocales disminuyen la dependencia de las gafas despu&eacute;s    de la cirug&iacute;a de catarata, lo que constituye una buena opci&oacute;n    en la recuperaci&oacute;n de la funci&oacute;n visual &oacute;ptima. </FONT>     <P>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>Palabras  clave:</B> Catarata, cirug&iacute;a, lente multifocal. <hr size="1" noshade></FONT>    <P>      <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>ABSTRACT </B></FONT>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>OBJECTIVE:</B>    To describe the visual results of 8 patients operated on from bilateral cataract    using Phaco-chop technique and implantation of OcuFlex multifocal intraocular    lens at &quot;Ram&oacute;n Pando Ferrer&quot; Cuban Institute of Ophthalmology    from September 2007 to February 2008.    <BR>   <B>METHODS:    </B>A prospective, longitudinal, observational and descriptive study was conducted    to analyze variables such as age, sex, visual acuity without correction and    best corrected acuity at different focal distances. Summary measures were used    in analyzing data, with the support of Microsoft Excel and Word 2003 system    for Windows XP.    ]]></body>
<body><![CDATA[<BR>   <B>RESULTS:</B>    It was found that average age was 68.5 years. The average visual acuity for    far distances before and after surgery, monocular and spontaneous (without correction)    was 0.17 and 0.8 respectively whereas corrected visual acuity was 0.41 and 0.98    respectively. At the postoperative phase, the spontaneous monocular vision in    93.75 % of patients reached J3 or better as intermediate visual acuity and J1    as near visual acuity.    <BR>   </FONT><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>CONCLUSIONS:</B>    The multifocal lenses reduce the dependency on glasses after cataract surgery,    which is a good choice for the recovery of optimal vision. </FONT>     <P>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B>Key  words:</B> cataract, surgery, multifocal lens. <hr size="1" noshade></FONT>    <P>&nbsp;</P>    <P>&nbsp;</P>    <P>      <P>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Durante la  cirug&iacute;a de catarata, se implanta un lente intraocular (LIO) en la bolsa  capsular. La fibrosis capsular posoperatoria y la contracci&oacute;n capsular  dan como resultado una visi&oacute;n firme de c&aacute;psula y lente. Dado que  el LIO no cambia su forma durante la contracci&oacute;n del m&uacute;sculo ciliar,  esto explica por qu&eacute; los pacientes con implante de LIO no acomodan.<SUP>1</SUP>  Algunos reportes describen alg&uacute;n grado de acomodaci&oacute;n en pacientes  pseudof&aacute;quicos con LIO monofocal. La observaci&oacute;n de que pacientes  af&aacute;quicos pueden presentar buena visi&oacute;n de cerca utilizando solamente  la correcci&oacute;n para lejos condujo a describir el fen&oacute;meno que se  ha llamado acomodaci&oacute;n aparente.<SUP>2</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">De  igual manera, se ha reportado que un porcentaje de pacientes pseudof&aacute;quicos  son capaces de leer sin necesidad de adici&oacute;n, hecho atribuido a caracter&iacute;sticas  del sistema &oacute;ptico como el di&aacute;metro pupilar y la profundidad del  foco, denominado pseudoacomodaci&oacute;n pseudof&aacute;quica,<SUP>3</SUP> o  a cambios refractivos din&aacute;micos causados por la interacci&oacute;n ante  la contracci&oacute;n del m&uacute;sculo ciliar y el sistema constituido por la  bolsa capsular, el LIO y la z&oacute;nula, denominado acomodaci&oacute;n pseudof&aacute;quica.<SUP>2</SUP>  </FONT>    ]]></body>
<body><![CDATA[<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Kellman,  iniciador, impulsor y verdadero padre de la Facoemulsificaci&oacute;n advirti&oacute;  que la cirug&iacute;a de catarata no ser&aacute; perfecta sin corregir la recuperaci&oacute;n  de la acomodaci&oacute;n para obtener una agudeza visual (AV) adecuada de lejos  y de cerca, por supuesto sin el uso de gafas.<SUP>4</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Recientemente  uno de los objetivos perseguidos es lograr un efecto acomodativo que permita a  los pacientes alcanzar buena visi&oacute;n en todas las distancias. Esta sin duda  es una frontera mucho m&aacute;s lejana y dif&iacute;cil pues son varias y complejas  las metas a vencer para lograrlo. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Actualmente  existen varias alternativas quir&uacute;rgicas para dar soluci&oacute;n a la presbicia.  Dentro de los procedimientos corneales uno de los m&aacute;s expandidos es la  monovisi&oacute;n con excimer l&aacute;ser,<SUP>5</SUP> lo cual trae consigo los  inconvenientes propios de la anisometrop&iacute;a y su influencia negativa sobre  la visi&oacute;n binocular.<SUP>6,7</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">El  uso de lentes de contacto y tallado de c&oacute;rneas multifocales con l&aacute;ser  resulta controversial por los efectos adversos como diplopia monocular, deslumbramiento,  halo y disminuci&oacute;n de la visi&oacute;n de contraste, as&iacute; como la  queratoplastia conductiva que modifica la curvatura corneal mediante contracci&oacute;n  del col&aacute;geno.<SUP>8,9</SUP> Las t&eacute;cnicas en la esclera, ya sea con  el uso de implantes o incisiones relajantes, resultan igualmente controversial.<SUP>10-12</SUP>  </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">El objetivo  de recuperar la acomodaci&oacute;n no se ha conseguido, pero la visi&oacute;n  de lejos, a media distancia y de cerca puede conseguirse con la aparici&oacute;n  de los LIO multifocales.<SUP>13,14</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">En  la actualidad existe un buen n&uacute;mero de lentes multifocales, tanto refractivas  como difractivas. No existe sin embargo, una lente multifocal universal que sea  superior al resto en todos los elementos t&eacute;cnicos valorables y que pueda  satisfacer las necesidades visuales de todos los pacientes.<SUP>15</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">El  contexto actual y las ventajas que reporta para la cirug&iacute;a de catarata  y para el paciente, el lente multifocal -con el cual entre el 80 y 90 % de los  pacientes no utilizan gafas despu&eacute;s de la cirug&iacute;a-<SUP>16</SUP>  conjuntamente con la posibilidad de que por primera vez se introduce en Cuba,  ha motivado esta comunicaci&oacute;n cuyo prop&oacute;sito es describir los resultados  visuales en 8 pacientes operados de catarata bilateral con la t&eacute;cnica de  Faco-chop e implante de lente intraocular multifocal modelo OcuFlex (RYMTF).</FONT>    <P>    <P>      <P>     ]]></body>
<body><![CDATA[<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B><FONT SIZE="3">M&Eacute;TODOS</FONT></B>  </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Se realiz&oacute;  un estudio observacional, descriptivo, longitudinal prospectivo donde se describieron  los resultados visuales en pacientes operados de catarata con la t&eacute;cnica  de Facoemulsificaci&oacute;n e implante de LIO multifocal modelo OcuFlex estilo  RYMTF, en el Instituto Cubano de Oftalmolog&iacute;a (ICO) &quot;Ram&oacute;n  Pando Ferrer&quot;, desde septiembre 2007 a febrero 2008. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">El  universo de estudio estuvo constituido por los pacientes portadores de esta patolog&iacute;a  que acudieron a operarse al Centro de Microcirug&iacute;a Ocular durante este  per&iacute;odo de tiempo. El tama&ntilde;o de la muestra fue de 8 pacientes (16  ojos) determinado por la cantidad de LIO multifocales disponibles y adem&aacute;s  se tuvo presente que la cirug&iacute;a se efectu&oacute; de manera bilateral (ambos  ojos). Para su conformaci&oacute;n se tuvieron en cuenta: </FONT>    <P>      <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><I>    <BR>   </I>Criterios de exclusi&oacute;n: </FONT>     <blockquote>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Catarata presenil      o senil con mejor agudeza visual corregida<B> </B>(MAVC)<B> </B>mayor de 0,5.      </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Diagn&oacute;stico      de catarata cong&eacute;nita o traum&aacute;tica.</FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      zonulolisis visible, facodonesis, o s&iacute;ndrome pseudoexfoliativo. </FONT></p>       ]]></body>
<body><![CDATA[<p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Anomal&iacute;as      cong&eacute;nitas asociadas como microc&oacute;rnea, aniridia. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Presencia de      patolog&iacute;as infecciosas asociadas. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      diagn&oacute;stico de glaucoma o cirug&iacute;a filtrante previa. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      patolog&iacute;as preexistentes como maculopat&iacute;a, distrofias corneales,      retinopat&iacute;a diab&eacute;tica. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Leucomas corneales      centrales que impidan adecuada visualizaci&oacute;n. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      astigmatismos mayores de 1 dioptr&iacute;a (moderados y severos). </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      miop&iacute;as e hipermetrop&iacute;as elevadas. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      di&aacute;metro pupilares extremos (menor de 2,5 mm y mayor de 5,5 mm). </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      cirug&iacute;a ocular previa. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      LIO monofocal implantado o no candidatos de implantaci&oacute;n bilateral.      </FONT></p>       ]]></body>
<body><![CDATA[<p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes cuya      profesi&oacute;n implique conducir de noche. </FONT></p>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Negaci&oacute;n      del paciente al estudio. </FONT></p> </blockquote>     <P>      <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><I>    <BR>   </I>Criterios de salida: </FONT>     <blockquote>       <p><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">- Pacientes con      complicaciones durante la cirug&iacute;a de catarata (ruptura radial de la      capsulorrexis, di&aacute;metro de la capsulorrexis mayor de 5,5 mm, zonulolisis,      ruptura de la c&aacute;psula posterior), no se le coloc&oacute; este tipo      de lente. </FONT></p> </blockquote>     <P>    <BR>      <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Para el cumplimiento    de los objetivos se realiz&oacute; a todos los pacientes un examen oftalmol&oacute;gico    completo [anejos oculares, segmento anterior, medios (dureza del cristalino),    reflejos pupilares, fondo de ojo] y tonometr&iacute;a de aplanaci&oacute;n,    as&iacute; como un estudio preoperatorio que incluy&oacute; agudeza visual sin    correcci&oacute;n y MAVC en distancias lejana, intermedia y de cerca. Adem&aacute;s    se realiz&oacute; biometr&iacute;a, queratometr&iacute;a y c&aacute;lculo del    LIO que se efectu&oacute; con el IOL Master y se us&oacute; la f&oacute;rmula    SRK/T. Se midi&oacute; tambi&eacute;n el di&aacute;metro pupilar con el Autorrefractoquerat&oacute;metro    Nidek 530-A, ya que este es un aspecto muy importante cuando se plantea la elecci&oacute;n    e implantaci&oacute;n de un lente multifocal. </FONT>     ]]></body>
<body><![CDATA[<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">La  cirug&iacute;a se realiz&oacute; en ambos ojos con un intervalo de un mes entre  el primero y el segundo ojo. A todos los casos se les realiz&oacute; la t&eacute;cnica  de facoemulsificaci&oacute;n por c&oacute;rnea clara para lo cual se utilizaron  los equipos de Facoemulsificaci&oacute;n Pulsar 2, del fabricante Optikon y el  modelo CV 7000 de la NIDEK, las puntas de faco fueron Coaxial de Titanio. Se trabaj&oacute;  con par&aacute;metros de poder ultras&oacute;nico, vac&iacute;o y flujo de acuerdo  con la dureza del n&uacute;cleo y con la t&eacute;cnica escogida por el cirujano  (Faco-Chop). Se coloc&oacute; el LIO multifocal OcuFlex estilo RYMTF procedente  de la India en el saco capsular, sitio id&oacute;neo para la implantaci&oacute;n  de dicho lente. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Este  es un lente plegable de una sola pieza con un di&aacute;metro total de 12,0/12,5  mm y &oacute;ptica de 5,75/6,0 mm formada por tres zonas. La zona central es de  1,5 mm y permite la visi&oacute;n de lejos. La segunda zona es la m&aacute;xima  adici&oacute;n y tiene un poder que es 4,5 dioptr&iacute;as m&aacute;s grandes  que el poder de la zona central, esta es adaptada para la visi&oacute;n de cerca  y tiene un di&aacute;metro de 2,5 mm. La tercera zona tiene una adici&oacute;n  de 1 dioptr&iacute;a mayor que el poder de la zona central y ocupa el resto de  la &oacute;ptica del lente. Esta zona es la adaptada para la visi&oacute;n intermedia  (<A HREF="#fig1_02">figura</A>). </FONT>    <P ALIGN="CENTER"><A NAME="fig1_02"></A><IMG SRC="/img/revistas/oft/v23n2/f0102210.jpg" WIDTH="400" HEIGHT="212">    
<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">    <BR>Se  realiz&oacute; seguimiento posoperatorio a las 24 horas, 7 d&iacute;as, 30 (1  mes), 60 (2 meses) y a los 90 (3 meses). En todas las consultas se practic&oacute;  un examen oftalmol&oacute;gico que permiti&oacute; valorar las complicaciones  posoperatorias y se determin&oacute; la agudeza visual sin correcci&oacute;n y  MAVC en distancias lejana (mediante la cartilla de Snellen), intermedia y cerca  (mediante la cartilla de Jaeger). Fue medida en ambos ojos por separado, monocular  y binocular, tanto en el preoperatorio como en todas las consultas del posoperatorio.  Tanto la AV intermedia como de cerca se expresaron desde J1 hasta J6.</FONT>    <P>    <P>      <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B><FONT SIZE="3">RESULTADOS</FONT></B>  </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">La distribuci&oacute;n  de los pacientes objeto de estudio se analiza y se observa que de los 8 pacientes  estudiados, tanto el sexo masculino como femenino represent&oacute; el 50 %. De  acuerdo con la edad, esta vari&oacute; entre los 57 y 77 a&ntilde;os con una media  de 68,5 a&ntilde;os. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">La  agudeza visual previo cirug&iacute;a se comport&oacute; seg&uacute;n lo esperado  a partir de los criterios de inclusi&oacute;n. Se evidenci&oacute; una recuperaci&oacute;n  posoperatoria en la cual a los tres meses coinciden los resultados de la agudeza  visual monocular cerca: 0,8 (&#177; 0,11), corregida: 0,98 (&#177; 0,07) y binocular  cerca: 0,83 (&#177; 0,07), corregida: 0,98 (&#177; 0,03). Se logr&oacute; una  mejor&iacute;a de 6 l&iacute;neas sin correcci&oacute;n y 5 l&iacute;neas con  correcci&oacute;n (p= 0,000) (<A HREF="/img/revistas/oft/v23n2/t0102210.gif">tabla 1</A>). </FONT>    
]]></body>
<body><![CDATA[<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">A  los tres meses de la cirug&iacute;a se recoge que para una AV intermedia (AVI)  se logra que el 93,75 % de los casos con correcci&oacute;n alcance el J1, excepto  en uno (un ojo) para un 6,25 % que obtuvo un J3. Los resultados en visi&oacute;n  binocular fueron mejores ya que sin correcci&oacute;n el 100 % alcanz&oacute;  J3 o mejor a&uacute;n y con adici&oacute;n excepto un caso (6,25 %) que alcanz&oacute;  J2, el resto ley&oacute; J1 (<A HREF="/img/revistas/oft/v23n2/t0202210.gif">tabla 2</A>). </FONT>    
<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">En  cuanto a la AV de cerca (AVC) posoperatoria (3 meses) todos los casos excepto  1 alcanzaron J1 tanto monocoular como binocular (<A HREF="/img/revistas/oft/v23n2/t0302210.gif">tabla  3</A>). </FONT>    
<P>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B><FONT SIZE="3">DISCUSI&Oacute;N</FONT></B>  </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Actualmente  la cirug&iacute;a de catarata puede realizarse a trav&eacute;s de una incisi&oacute;n  peque&ntilde;a e implantar un LIO plegable, pero en la mayor&iacute;a de los casos  monofocal. Este tipo de lente presenta una amplitud de foco limitada, adem&aacute;s  de la p&eacute;rdida de la acomodaci&oacute;n fisiol&oacute;gica, lo que obliga  al paciente al uso de cristales para la visi&oacute;n de cerca,<SUP>17-19</SUP>  sin embargo, los LIO multifocales permiten la visi&oacute;n tanto de lejos como  a distancias intermedias y de cerca. De acuerdo con la literatura mundial, una  LIO multifocal proporciona una AV de lejos espont&aacute;nea y corregida comparable  con un LIO monofocal y en cuanto a la AV de cerca espont&aacute;nea, tiene mejores  resultados.<SUP>20,21</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">En  otros trabajos realizados se tienen resultados similares con respecto a los obtenidos  en cuanto a la AV a distancia.<SUP>22-24</SUP> En el estudio comparativo de la  funci&oacute;n visual con LIO multifocal y monofocal realizado por <I>G&oacute;mez,</I><SUP>25  </SUP>el grupo con LIO multifocal formado por 27 pacientes con edad media de 65  a&ntilde;os, tiene el 85 % AVDSC monocular superior a 0;5, con una media de 0,79;  mientras que la corregida es en el 100 % superior a 0,6 con una media de 0,96.  </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Diferentes  han sido los LIO multifocales que se han fabricado y los cuales han sido evaluados,  dentro de ellos el ReSTOR que constituy&oacute; una revoluci&oacute;n. Su implante  bilateral fue estudiado en Venezuela por <I>Rinc&oacute;n</I><SUP>26</SUP>, con  el que se tiene una AVDM espont&aacute;nea de 0,8 (20/25) o m&aacute;s y una corregida  de la unidad (20/20) en el 89 % de los pacientes, resultado comparable con los  ensayos hecho por la FDA en Estados Unidos donde AVDSC es de 0,8 (20/25) o m&aacute;s  en el 85 % de los ojos.<SUP>26</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><I>Moreira</I><SUP>17</SUP>  en un trabajo sobre resultados visuales con implante de LIO multifocal bilateral  SA-40N, realizado en Minas de Gerais, Brasil, donde la edad media de los pacientes  es de 56,1 a&ntilde;os, tiene una AVD monocular sin correcci&oacute;n y corregida  posoperatoria entre 1,0 (20/20) y 0,6 (20/30) en el 67,3 y el 94,8 % respectivamente.  Resultados semejantes son reportados en la literatura.<SUP>27,28</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">En  estudios realizados por <I>Liekfeld</I><SUP>29</SUP> se observ&oacute; que la  AVDSC media monocular y binocular es de 0,74 (&#177; 0,02) y 0,89 (&#177; 0,19)  respectivamente; y la AVDCC es de 0,93 (&#177; 0,21) y 1,08 (&#177; 0,23). Estos  resultados se corresponden con los encontrados por <I>Josef</I><SUP>30</SUP> en  la correcci&oacute;n de la presbicia con LIO multifocal donde la AVDSC monocular  preoperatoria de 0,22 mejora a 0,8 en el posoperatorio. En visi&oacute;n binocular  se obtuvo resultados semejantes. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">La  rehabilitaci&oacute;n visual ideal despu&eacute;s de una cirug&iacute;a de catarata  ser&iacute;a aquella que proporcionase una visi&oacute;n satisfactoria tanto para  lejos como para cerca sin el uso de espejuelos y en ausencia de la acomodaci&oacute;n  natural del cristalino, una alternativa ser&iacute;a el implante de un LIO multifocal<SUP>31,32  </SUP>y los resultados de este trabajo lo afirman. </FONT>    ]]></body>
<body><![CDATA[<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">La  adici&oacute;n necesaria para alcanzar J1 en visi&oacute;n intermedia en este  estudio oscil&oacute; entre +1,25 y +1,5 dioptr&iacute;as, elemento coincidente  con la empleada por otros investigadores.<SUP>23,26</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Estos  resultados coinciden con <I>Josef</I>,<SUP>30</SUP> quien en su experiencia con  LIO TECNIS 2M900 multifocal en cirug&iacute;a de catarata y en correcci&oacute;n  de la presbicia, refiere que el 60 % de los casos leen un J2 y el 90 % un J3 en  distancia intermedia sin correcci&oacute;n y en visi&oacute;n monocular. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">En  la investigaci&oacute;n realizada en el Instituto Oftalmol&oacute;gico IUMO en  Caracas, Venezuela, con LIO ReSTOR,<SUP>26</SUP> se recoge AVISC monocular de  J3 (20/40-0,5) o mejor en el 94 % de los casos y corregida de J1 (20/25-0,8) en  el 95,13 %, valores superiores a los encontrados en la presente investigaci&oacute;n.  Otros trabajos muestran resultados semejantes.<SUP>23</SUP> </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Varios  reportes han expresado que la AV de cerca es mejor en pacientes con implante de  LIO multifocal que con monofocal,<SUP>33-35</SUP> sin embargo, algunos trabajos  como el de <I>Kim</I>,<SUP>36</SUP> en el que se estudian 40 ojos con implante  de LIO multifocal en pacientes de edad media de 64,3 (&#177; 7,51) a&ntilde;os,  tiene una AVC de J3 (0,54 &#177; 0,20), similar a la obtenida en el grupo con  implante de LIO monofocal. <I>Vingolo</I><SUP>24 </SUP>tiene resultados similares,  AVC de J3, aunque s&iacute; fue mejor en el grupo con LIO multifocal, al compararlo  con el monofocal. Resultados semejantes son encontrados en B&eacute;lgica, donde  el 95 % leen J1 o mejor en visi&oacute;n monocular sin correcci&oacute;n y el  100 % leen J2 o mejor,<SUP>30</SUP> esta misma situaci&oacute;n es reportada por  otros autores.<SUP>23</SUP> <I>Rinc&oacute;n</I><SUP>26</SUP> presenta en su trabajo  AVCSC monocular de J1 (20/25-0,8) o mejor en el 90 % de los pacientes y corregida  en el 98,75 %. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Otras  investigaciones tienen reportes diferentes a los obtenidos en este trabajo, menos  alentadores, como en el estudio de los resultados visuales con implante bilateral  de LIO multifocal SA-40N, en Brasil donde en visi&oacute;n binocular, el 50 %  le&iacute;an J1 y el 43,1 % J2 sin correcci&oacute;n, semejante a otros autores.<SUP>23,37</SUP>  <I>Fern&aacute;ndez-Pineda</I><SUP>22</SUP> en su labor presenta que el 100 %  de los pacientes tienen AVCSC en visi&oacute;n monocular de J5 o mejor. </FONT>    <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Podemos  resumir en el estudio realizado con el implante de LIO multifocal Ocuflex en el  ICO &quot;Ram&oacute;n Pando Ferrer&quot;, que la AV de lejos y cerca tanto monocular  como binocular sin correcci&oacute;n fueron excelentes y casi todos los pacientes  alcanzaron una visi&oacute;n intermedia funcional, lo que favoreci&oacute; la  eliminaci&oacute;n a la dependencia de los espejuelos.</FONT>    <P>    <P>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><B><FONT SIZE="3">REFERENCIAS  BIBLIOGR&Aacute;FICAS</FONT></B> </FONT>     <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">1. Ib&aacute;&ntilde;ez    MA, Ramos K. Lentes acomodativos an&aacute;lisis y resultados. Rev Mex Oftalmol;    Sep-Oct. 2005;79(5):263-7. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">2. Morales ME.    Presbicia. Diferentes Opciones de Manejo desde el Punto de Vista Intraocular.    En: Centurion V, Nicoli C, Villar-Kuri J. El libro del Cristalino de las Am&eacute;ricas.    Livraria Santos Editora. 2007;933-44. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">3. Langenbucher    A, Huber S, Nguyen NW, et al. Measurement of accommodation after implantation    of an accommodating posterior chamber intraocular lens. J Cataract Refract Surg.    2003;29:677-85. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">4.  Fern&aacute;ndez-Vega L, Alonso J. Facoemulsificaci&oacute;n y emetrop&iacute;a.  Sociedad Espa&ntilde;ola de Cirug&iacute;a Implanto-Refractiva 2002. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">5.  Charters L. How to evaluate presbyopic patients for monovision? Ophthalmology  Times. 2000;28:109. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">6. Cross W. Theory    behind surgical correction of presbyopia. Ophthalmol Clin North Am. 2001;14(2):315-33.    </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">7. Jain S, Ou R,    Azar DT. Monovision outcomes in the presbyopic individuals after Refractive    Surgery. Ophthalmology. 2001;1408-30. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">8. Atwood J. Presbyopic    contact lenses. Curr Opin Opthalmol 2000;11(4):296-8. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">9.  Chynn EW. Many mysteries about presbyopia still remain to be solved: Better understanding  of the mechanisms is needed to determine refractive surgery techniques. [En l&iacute;nea].  1999 Abril 1. <FONT COLOR="#000000">[Fecha de acceso 17 de Agosto del 2006]</FONT>.  Disponible en: URL: <U><FONT  COLOR="#0000ff"><A HREF="http://www.findarticles.com/cf_0/m0VEY/7_24/54299" TARGET="_blank">http://www.findarticles.com/cf_0/m0VEY/7_24/54299</A></FONT></U>.  </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">10. Ostrin LA,    Kasthurirangan S, Glasser A. Evaluation of a satisfied bilateral scleral expansion    band patient. J Cataract Refract Surg. 2004;30:1445-53. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">11. Malecaze FJ,    Gazagne CS, Tarroux MC, Gorrand JM. Scleral expansion bands for presbyopia.    Ophthalmology 2001;108:2165-71.</FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">12. Qazi MA, Pepose    JS, Shuster JJ. Implantation of scleral expansion band segments for the treatment    of presbyopia. Am J Ophthalmol. 2002;134:808-15. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">13. Nijkamp M,    Dolders M, de Brabander J, van den Borne B, Hendrikse F, Nuijts R. Effectiveness    of multifocal intraocular lenses to correct presbyopia after cataract surgery:    A randomized controlled trial. Opthalmology. 2004;11:1832-9. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">14. Charters L.    Accommodative IOL may help presbyopia. [En l&iacute;nea]. 2000 Julio 1. [Fecha    de acceso 17 de Agosto del 2006]</FONT>. <font face="Verdana, Arial, Helvetica, sans-serif" size="2">Disponible    en: URL: </font><U><FONT COLOR="#0000ff" FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2"><A HREF="http://www.findarticles.com/cf_0/m0VEY/13_25/63792650/p1/article.jhtml" TARGET="_blank">http://www.findarticles.com/cf_0/m0VEY/13_25/63792650/p1/article.jhtml</A></FONT></U>    .    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">15. Lorente R,    V&aacute;zquez de Parga P. Eligiendo la mejor Lente Multifocal. En: Centurion    V, Nicoli C, Villar-Kuri J. El libro del Cristalino de las Am&eacute;ricas.    Livraria Santos Editora. 2007;275-89. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">16.  Centurion V, Nicoli C, Villar-Kuri J. El libro del Cristalino de las Am&eacute;rica.  Livraria Santos Editora. 2007;275-302. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">17.  Moreira C, Marciano SE, Reis M, Bicalho R, Queiroz R. Resultados do implante bilateral  de lente intra-ocular multifocal SA-40N no Hospital de Olhos de Minas Gerais.  Arq. Bras. Oftalmol. 68(1) S&atilde;o Paulo. [en l&iacute;nea]. Ene./feb. 2005.  [Fecha de acceso: 10 de enero de 2008]. Disponible en: <U><FONT  COLOR="#0000ff"><A HREF="http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492005000100021&lng=es" TARGET="_blank">http://www.scielo.br/scielo.php?script=sci_arttext&amp;pid=S0004  -27492005000100021&amp;lng=es</A></FONT></U>. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">18.  Steinert RF, Aker BL, Trentacost DJ, Smith PJ, Tarantino N. A prospective comparative  study of the AMO Array zonal-progressive multifocal silicone intraocular lens  and a monofocal intraocular lens. J Cataract Refract Surg. 1999;106(7):1243-55.  [&#160;<U><FONT  COLOR="#0000ff">    Links</FONT></U>&#160;] Commented in: Ophthalmology. 2000;107(10):1801.  </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">19. Sedgewick  JH, Orillac R, Link C. Array multifocal intraocular lens in a charity hospital  training program - a resident's experience. J Cataract Refract Surg. 2002;28(7):1205-10.  [ <U><FONT COLOR="#0000ff">    Links</FONT></U>&#160;] Commented in: J Cataract Refract  Surg. 2003;29(5):858-9. </FONT>    ]]></body>
<body><![CDATA[<!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">20.  Haring G, Dick B, Krummenauer F, Weissmantel U, Kroncke W. Subjective photic phenomena  with refractive multifocal and monofocal intraocular lenses. Results of a multicenter  questionnaire. J Cataract Refract Surg. 2001;27(2):245-9. [&#160;<U><FONT  COLOR="#0000ff">    Links</FONT></U>&#160;] Commented in: J Cataract Refract Surg.  2001;27(7):1148. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">21.  Akaishi L, Ara&uacute;jo AG, Santos RC, Santos PM. Acuidade visual em implantes  bilaterais de lentes intra-oculares monofocais e multifocais. Arq Bras Oftalmol.  2003;66(2):199-205. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">22. Pineda-Fern&aacute;ndez    A, Jaramillo J, Celis V, et al. Refractive outcomes after bilateral multifocal    intraocular lens implantation. J Catarct Refract Surg 2004;30:685-8. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">23. Blaylock  JF, Si Z, Vickers C. Visual and refractive status at different focal distances  after implantation of the ReSTOR multifocal intraocular lens. J Cataract Refract  Surg. 2006 Sep;32(9):1464-73. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">24.  Vingolo EM, Grenga P, Iacobelli L, Grenga R. Visual acuity and contrast sensitivity:  AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular  lenses. J Cataract Refract Surg. 2007 Jul;33(7):1244-7.</FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">25.  G&oacute;mez I, Orbegozo J, Solaguren I, Alberdi T. Estudio comparativo de la  funci&oacute;n visual entre lentes intraoculares multifocales y monofocales. [en  l&iacute;nea]. 2000 Marzo 1. [Fecha de acceso 10 de Enero del 2008]. Disponible  en: URL: <A HREF="http://www.oftalmo.com/secoir/secoir2000/rev00-1/00a-04.htm" TARGET="_blank">http://www.oftalmo.com/secoir/secoir2000/rev00-1/00a-04.htm</A>  </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">26. Rinc&oacute;n  JL. ReSTOR bilateral, un rango completo de calidad visual. En Asociaci&oacute;n  con Ophtalmology Times. Oct 2007. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">27. Javitt JC,    Steinert RF. Cataract extraction with multifocal intraocular lens implantation:    a multinational clinical trial evaluating clinical, functional, and quality-of-life    outcomes. Opthalmology 2000;107:2040-8. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">28.  Jacobi PC, Dietlein TS, Luke C, Jacobi FK. Multifocal intraocular lens implantation  in presbyopic patients with unilateral cataract. Ophthalmology. 2002;109(4):680-6.&#160;  </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">29. Liekfeld  A, Hartmann C. Presbyopia Correction-Renaissance of the Multifocal Lens? Ophthalmo-Chirurgie.  2003;15:69-76. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">30.  Josef F. LIO multifocal en la correcci&oacute;n de la Presbicia. Highlights of  Ophthalmology. 2007;35(5):6-8. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">31.  Kamath GG, Prasad S, Danson A, Phillips RP. Visual outcome with the array multifocal  intraocular lens in patients with concurrent eye disease. J Cataract Refract Surg.  2000;26(4):576-81. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">32.  Shoji N, Shimizu K. Binocular function of the patient with the refractive multifocal  intraocular lens. J Cataract Refract Surg. 2002;28(6):1012-22. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">33.  Sen HN, Sarikkola AU, Uusitalo RJ, Laatikainen L. Quality of vision after AMO  Array multifocal intraocular lens implantation. J Cataract Refract Surg. 2004  Dec; 30(12):2483-93. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">34. Mont&eacute;s-Mic&oacute;    R, Ali&oacute; JL. Distance and near contrast sensitivity function after multifocal    intraocular lens implantation. J Cataract Refract Surg. 2003;29 (4):703-11.    </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">35. Leyland M,    Zinicola E. Multifocal versus monofocal intraocular lenses in cataract surgery:    a systematic review. Ophthalmology 2003;110:1789-98. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">36. Kim CY, Chung    SH, Kim T, Cho YJ, Yoon G, Seo KY. Comparison of Higher-Order Aberration and    Contrast Sensitivity in Monofocal and Multifocal Intraocular Lenses. Yonsei    Med J. 2007;48(4):627-33. </FONT>    <!-- ref --><P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">37.  Brydon KW, Tokarewicz AC, Nichols BD. AMO Array multifocal lens versus monofocal  correction in cataract surgery. J Cataract Refract Surg. 2000;26(1):96-100.</FONT>    <P>    ]]></body>
<body><![CDATA[<P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">&#160;  </FONT>    <P>     <P>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Recibido:  16 de julio de 2010.    <BR></FONT><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Aprobado:  24 de octubre de 2010.</FONT>    <P>    <P>    <P>     <P>     <P><FONT FACE="Verdana, Arial, Helvetica, sans-serif" SIZE="2">Dra.  <I>Eneida de la C. P&eacute;rez Candelaria.</I> Instituto Cubano de Oftalmolog&iacute;a  &quot;Ram&oacute;n Pando Ferrer&quot;. Ave. 76 No. 3104 entre 31 y 41 Marianao,  La Habana, Cuba. Correo electr&oacute;nico: <U><FONT COLOR="#0000ff"><A HREF="mailto:eneidaperez@infomed.sld.cu">eneidaperez@infomed.sld.cu</A></FONT></U>  </FONT>      ]]></body>
<body><![CDATA[ ]]></body>
<back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ibáñez]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Ramos]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Lentes acomodativos análisis y resultados.]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>Sep-</year>
<month>Oc</month>
<day>t.</day>
<volume>79</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>263-7</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morales]]></surname>
<given-names><![CDATA[ME.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Diferentes Opciones de Manejo desde el Punto de Vista Intraocular.]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Centurion]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Nicoli]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Villar-Kuri]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[El libro del Cristalino de las Américas.]]></source>
<year>2007</year>
<page-range>933-44</page-range><publisher-name><![CDATA[Livraria Santos Editora]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Langenbucher]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Huber]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Nguyen]]></surname>
<given-names><![CDATA[NW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measurement of accommodation after implantation of an accommodating posterior chamber intraocular lens]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2003</year>
<volume>29</volume>
<page-range>677-85</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernández-Vega]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Alonso]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[Facoemulsificación y emetropía.]]></source>
<year>2002</year>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Charters]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[How to evaluate presbyopic patients for monovision?]]></article-title>
<source><![CDATA[Ophthalmology Times]]></source>
<year>2000</year>
<volume>28</volume>
<page-range>109</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cross]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Theory behind surgical correction of presbyopia]]></article-title>
<source><![CDATA[Ophthalmol Clin North Am.]]></source>
<year>2001</year>
<volume>14</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>315-33</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jain]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Ou]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Azar]]></surname>
<given-names><![CDATA[DT.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Monovision outcomes in the presbyopic individuals after Refractive Surgery.]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2001</year>
<page-range>1408-30</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Atwood]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Presbyopic contact lenses]]></article-title>
<source><![CDATA[Curr Opin Opthalmol]]></source>
<year>2000</year>
<volume>11</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>296-8</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chynn]]></surname>
<given-names><![CDATA[EW.]]></given-names>
</name>
</person-group>
<source><![CDATA[Many mysteries about presbyopia still remain to be solved:: Better understanding of the mechanisms is needed to determine refractive surgery techniques.]]></source>
<year>1999</year>
<month> A</month>
<day>br</day>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ostrin]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Kasthurirangan]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Glasser]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of a satisfied bilateral scleral expansion band patient]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2004</year>
<volume>30</volume>
<page-range>1445-53</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Malecaze]]></surname>
<given-names><![CDATA[FJ]]></given-names>
</name>
<name>
<surname><![CDATA[Gazagne]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
<name>
<surname><![CDATA[Tarroux]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Gorrand]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Scleral expansion bands for presbyopia]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2001</year>
<volume>108</volume>
<page-range>2165-71</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Qazi]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Pepose]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Shuster]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implantation of scleral expansion band segments for the treatment of presbyopia]]></article-title>
<source><![CDATA[Am J Ophthalmol.]]></source>
<year>2002</year>
<volume>134</volume>
<page-range>808-15</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nijkamp]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Dolders]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[de Brabander]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[van den Borne]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Hendrikse]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Nuijts]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effectiveness of multifocal intraocular lenses to correct presbyopia after cataract surgery:: A randomized controlled trial.]]></article-title>
<source><![CDATA[Opthalmology]]></source>
<year>2004</year>
<volume>11</volume>
<page-range>1832-9</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Charters]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<source><![CDATA[Accommodative IOL may help presbyopia.]]></source>
<year>2000</year>
<month> J</month>
<day>ul</day>
</nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lorente]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Vázquez de Parga]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Eligiendo la mejor Lente Multifocal.]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Centurion]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Nicoli]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Villar-Kuri]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[El libro del Cristalino de las Américas.]]></source>
<year>2007</year>
<page-range>275-89</page-range><publisher-name><![CDATA[Livraria Santos Editora]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Centurion]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Nicoli]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Villar-Kuri]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<source><![CDATA[El libro del Cristalino de las América.]]></source>
<year>2007</year>
<page-range>275-302</page-range><publisher-name><![CDATA[Livraria Santos Editora]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moreira]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Marciano]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
<name>
<surname><![CDATA[Reis]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bicalho]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Queiroz]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="pt"><![CDATA[Resultados do implante bilateral de lente intra-ocular multifocal SA-40N no Hospital de Olhos de Minas Gerais.]]></article-title>
<source><![CDATA[Arq. Bras. Oftalmol]]></source>
<year>Ene.</year>
<month>/f</month>
<day>eb</day>
<volume>68</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steinert]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
<name>
<surname><![CDATA[Aker]]></surname>
<given-names><![CDATA[BL]]></given-names>
</name>
<name>
<surname><![CDATA[Trentacost]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[PJ]]></given-names>
</name>
<name>
<surname><![CDATA[Tarantino]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A prospective comparative study of the AMO Array zonal-progressive multifocal silicone intraocular lens and a monofocal intraocular lens]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>1999</year>
<volume>106</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1243-55</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sedgewick]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Orillac]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Link]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Array multifocal intraocular lens in a charity hospital training program - a resident's experience]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2002</year>
<volume>28</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1205-10</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haring]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Dick]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Krummenauer]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Weissmantel]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Kroncke]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Subjective photic phenomena with refractive multifocal and monofocal intraocular lenses: Results of a multicenter questionnaire]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2001</year>
<volume>27</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>245-9</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Akaishi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Araújo]]></surname>
<given-names><![CDATA[AG]]></given-names>
</name>
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[RC]]></given-names>
</name>
<name>
<surname><![CDATA[Santos]]></surname>
<given-names><![CDATA[PM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Acuidade visual em implantes bilaterais de lentes intra-oculares monofocais e multifocais]]></article-title>
<source><![CDATA[Arq Bras Oftalmol.]]></source>
<year>2003</year>
<volume>66</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>199-205</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pineda-Fernández]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Jaramillo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Celis]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Refractive outcomes after bilateral multifocal intraocular lens implantation]]></article-title>
<source><![CDATA[J Catarct Refract Surg]]></source>
<year>2004</year>
<volume>30</volume>
<page-range>685-8</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Blaylock]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Si]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Vickers]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Visual and refractive status at different focal distances after implantation of the ReSTOR multifocal intraocular lens.]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<month> S</month>
<day>ep</day>
<volume>32</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1464-73</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vingolo]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[Grenga]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Iacobelli]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Grenga]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Visual acuity and contrast sensitivity:: AcrySof ReSTOR apodized diffractive versus AcrySof SA60AT monofocal intraocular lenses.]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2007</year>
<month> J</month>
<day>ul</day>
<volume>33</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1244-7</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Orbegozo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Solaguren]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Alberdi]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<source><![CDATA[Estudio comparativo de la función visual entre lentes intraoculares multifocales y monofocales.]]></source>
<year>2000</year>
<month> M</month>
<day>ar</day>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rincón]]></surname>
<given-names><![CDATA[JL.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[ReSTOR bilateral, un rango completo de calidad visual.]]></article-title>
<source><![CDATA[]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Javitt]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Steinert]]></surname>
<given-names><![CDATA[RF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cataract extraction with multifocal intraocular lens implantation: a multinational clinical trial evaluating clinical, functional, and quality-of-life outcomes]]></article-title>
<source><![CDATA[Opthalmology]]></source>
<year>2000</year>
<volume>107</volume>
<page-range>2040-8</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jacobi]]></surname>
<given-names><![CDATA[PC]]></given-names>
</name>
<name>
<surname><![CDATA[Dietlein]]></surname>
<given-names><![CDATA[TS]]></given-names>
</name>
<name>
<surname><![CDATA[Luke]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobi]]></surname>
<given-names><![CDATA[FK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multifocal intraocular lens implantation in presbyopic patients with unilateral cataract]]></article-title>
<source><![CDATA[Ophthalmology.]]></source>
<year>2002</year>
<volume>109</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>680-6</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liekfeld]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hartmann]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Presbyopia Correction-Renaissance of the Multifocal Lens?]]></article-title>
<source><![CDATA[Ophthalmo-Chirurgie]]></source>
<year>2003</year>
<volume>15</volume>
<page-range>69-76</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Josef]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[LIO multifocal en la corrección de la Presbicia]]></article-title>
<source><![CDATA[Highlights of Ophthalmology.]]></source>
<year>2007</year>
<volume>35</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>6-8</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kamath]]></surname>
<given-names><![CDATA[GG]]></given-names>
</name>
<name>
<surname><![CDATA[Prasad]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Danson]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Phillips]]></surname>
<given-names><![CDATA[RP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Visual outcome with the array multifocal intraocular lens in patients with concurrent eye disease]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2000</year>
<volume>26</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>576-81</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shoji]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Shimizu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Binocular function of the patient with the refractive multifocal intraocular lens]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2002</year>
<volume>28</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1012-22</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sen]]></surname>
<given-names><![CDATA[HN]]></given-names>
</name>
<name>
<surname><![CDATA[Sarikkola]]></surname>
<given-names><![CDATA[AU]]></given-names>
</name>
<name>
<surname><![CDATA[Uusitalo]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Laatikainen]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quality of vision after AMO Array multifocal intraocular lens implantation.]]></article-title>
<source><![CDATA[Cataract Refract Surg]]></source>
<year>2004</year>
<month> D</month>
<day>ec</day>
<volume>30</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>2483-93</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Montés-Micó]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Alió]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Distance and near contrast sensitivity function after multifocal intraocular lens implantation]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2003</year>
<volume>29</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>703-11</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Leyland]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Zinicola]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multifocal versus monofocal intraocular lenses in cataract surgery: a systematic review]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2003</year>
<volume>110</volume>
<page-range>1789-98</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[CY]]></given-names>
</name>
<name>
<surname><![CDATA[Chung]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Cho]]></surname>
<given-names><![CDATA[YJ]]></given-names>
</name>
<name>
<surname><![CDATA[Yoon]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Seo]]></surname>
<given-names><![CDATA[KY]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of Higher-Order Aberration and Contrast Sensitivity in Monofocal and Multifocal Intraocular Lenses]]></article-title>
<source><![CDATA[Yonsei Med J.]]></source>
<year>2007</year>
<volume>48</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>627-33</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brydon]]></surname>
<given-names><![CDATA[KW]]></given-names>
</name>
<name>
<surname><![CDATA[Tokarewicz]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Nichols]]></surname>
<given-names><![CDATA[BD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[AMO Array multifocal lens versus monofocal correction in cataract surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2000</year>
<volume>26</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>96-100</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>