<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-2176</journal-id>
<journal-title><![CDATA[Revista Cubana de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Oftalmol]]></abbrev-journal-title>
<issn>0864-2176</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-21762016000200009</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Principales métodos para el cálculo de la lente intraocular después de la cirugía refractiva corneal]]></article-title>
<article-title xml:lang="en"><![CDATA[Fundamental methods for calculation of intraocular lens after corneal refractive surgery]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cárdenas Díaz]]></surname>
<given-names><![CDATA[Taimí]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández López]]></surname>
<given-names><![CDATA[Iván]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Guerra Almaguer]]></surname>
<given-names><![CDATA[Michel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cruz Izquierdo]]></surname>
<given-names><![CDATA[Dunia]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cuan Aguilar]]></surname>
<given-names><![CDATA[Yoriel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez Candelaria]]></surname>
<given-names><![CDATA[Eneida]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Cubano de Oftalmología Ramón Pando Ferrer  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2016</year>
</pub-date>
<volume>29</volume>
<numero>2</numero>
<fpage>271</fpage>
<lpage>284</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762016000200009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-21762016000200009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-21762016000200009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Con el surgimiento y el desarrollo de la cirugía refractiva corneal se han podido corregir quirúrgicamente a millones de pacientes con defectos refractivos. Con el cursar de los años comienza a opacarse fisiológicamente el cristalino, y disminuye la agudeza visual en estos pacientes a quienes se les modificó la curvatura corneal. Ante la necesidad de remover el cristalino y de calcular una lente intraocular de potencia adecuada para conseguir la emetropía, surge un nuevo reto a la Oftalmología. El cálculo de la lente intraocular en pacientes con cirugía refractiva corneal es mucho más complejo, pues además de tener longitudes axiales extremas, se añaden factores por la intervención previa que alteran la predictibilidad del resultado visual, con la aplicación de las fórmulas de cálculo de lente intraocular existentes. Se han descrito varios métodos que permiten determinar correctamente la potencia de la lente a implantar, dependiendo de los datos de los que se dispongan; de ahí la motivación para realizar una revisión de diferentes publicaciones con el propósito de describir los principales métodos empleados para realizar el cálculo de la lente intraocular en estos pacientes. Se utilizó la plataforma Infomed, específicamente la Biblioteca Virtual de Salud, con todos sus buscadores.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[With the emergence and development of the corneal refractive surgery, the refractive defects of millions of patients have been surgically corrected. As time goes by, the physiological opacification of the crystalline lens begins, thus reducing the visual acuity of those patients whose corneal curvature has been modified. Should the crystalline lens be modified and should the intraocular lens power be adequately calculated to achieve emetropia, ophthalmology faces then a new challenge. The intraocular lens calculation in patients with corneal refractive surgery is much more complex since, in addition to extreme axial lengths, there are factors derived from the previous surgery that alter predictability of the visual result, with the use of existing intraocular lens calculation formulae. Several methods have been so far described, which allow correctly determining the lens power to be implanted, depending on available data. This was the main reason for making a review of different publications to describe the main methods for intraocular lens calculation in these patients. Infomed platform, mainly the virtual library of health, was used with all its searchers.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[cirugía refractiva corneal]]></kwd>
<kwd lng="es"><![CDATA[cirugía de catarata]]></kwd>
<kwd lng="es"><![CDATA[cálculo de lente intraocular]]></kwd>
<kwd lng="en"><![CDATA[corneal refractive surgery]]></kwd>
<kwd lng="en"><![CDATA[cataract surgery]]></kwd>
<kwd lng="en"><![CDATA[lens intraocular calculation]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="right" style='text&#45;align:right;line&#45;height:normal'><font face="verdana" size="2"><b>REVISI&Oacute;N</b></font></p>  	    <p align="right" style='text&#45;align:right;line&#45;height:normal'><font face="verdana" size="2"><b>&nbsp;</b></font></p>  	     <p style='text&#45;align:left;line&#45;height:normal' align="left"><font face="verdana" size="2"><b><font size="4">Principales    m&eacute;todos para el c&aacute;lculo de la lente intraocular despu&eacute;s    de la cirug&iacute;a refractiva corneal</font></b></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b><font size="3">Fundamental    methods for calculation of intraocular lens after corneal refractive surgery</font></b></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>Taim&iacute;    C&aacute;rdenas D&iacute;az, Iv&aacute;n Hern&aacute;ndez L&oacute;pez, Michel    Guerra Almaguer, Dunia Cruz Izquierdo, Yoriel Cuan Aguilar, Eneida P&eacute;rez    Candelaria</b></font>    <br>       ]]></body>
<body><![CDATA[<br>   <font face="verdana" size="2">Instituto Cubano de Oftalmolog&iacute;a "Ram&oacute;n    Pando Ferrer". La Habana, Cuba.</font></p>     <p style='line&#45;height:normal' align="left">&nbsp;</p>     <p style='line&#45;height:normal' align="left">&nbsp;</p> <hr align="left">     <div align="left"><font face="verdana" size="2"><b>RESUMEN</b></font> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Con    el surgimiento y el desarrollo de la cirug&iacute;a refractiva corneal se han    podido corregir quir&uacute;rgicamente a millones de pacientes con defectos    refractivos. Con el cursar de los a&ntilde;os comienza a opacarse fisiol&oacute;gicamente    el cristalino, y disminuye la agudeza visual en estos pacientes a quienes se    les modific&oacute; la curvatura corneal. Ante la necesidad de remover el cristalino    y de calcular una lente intraocular de potencia adecuada para conseguir la emetrop&iacute;a,    surge un nuevo reto a la Oftalmolog&iacute;a. El c&aacute;lculo de la lente    intraocular en pacientes con cirug&iacute;a refractiva corneal es mucho m&aacute;s    complejo, pues adem&aacute;s de tener longitudes axiales extremas, se a&ntilde;aden    factores por la intervenci&oacute;n previa que alteran la predictibilidad del    resultado visual, con la aplicaci&oacute;n de las f&oacute;rmulas de c&aacute;lculo    de lente intraocular existentes. Se han descrito varios m&eacute;todos que permiten    determinar correctamente la potencia de la lente a implantar, dependiendo de    los datos de los que se dispongan; de ah&iacute; la motivaci&oacute;n para realizar    una revisi&oacute;n de diferentes publicaciones con el prop&oacute;sito de describir    los principales m&eacute;todos empleados para realizar el c&aacute;lculo de    la lente intraocular en estos pacientes. Se utiliz&oacute; la plataforma Infomed,    espec&iacute;ficamente la Biblioteca Virtual de Salud, con todos sus buscadores.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>Palabras    clave:</b> cirug&iacute;a refractiva corneal; cirug&iacute;a de catarata; c&aacute;lculo    de lente intraocular.</font></p> <hr align="left">     <div align="left"><font face="verdana" size="2"><b>ABSTRACT</b></font> </div>     <p style='margin&#45;bottom:12.0pt;line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">With    the emergence and development of the corneal refractive surgery, the refractive    defects of millions of patients have been surgically corrected. As time goes    by, the physiological opacification of the crystalline lens begins, thus reducing    the visual acuity of those patients whose corneal curvature has been modified.    Should the crystalline lens be modified and should the intraocular lens power    be adequately calculated to achieve emetropia, ophthalmology faces then a new    challenge. The intraocular lens calculation in patients with corneal refractive    surgery is much more complex since, in addition to extreme axial lengths, there    are factors derived from the previous surgery that alter predictability of the    visual result, with the use of existing intraocular lens calculation formulae.    Several methods have been so far described, which allow correctly determining    the lens power to be implanted, depending on available data. This was the main    reason for making a review of different publications to describe the main methods    for intraocular lens calculation in these patients. Infomed platform, mainly    the virtual library of health, was used with all its searchers.&nbsp;</font></p>     <p style='margin&#45;bottom:10.0pt;line&#45;height:normal;text&#45;autospace: ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2"><b>Key    words</b>: corneal refractive surgery; cataract surgery; lens intraocular calculation.</font></p> <hr align="left">     <p style='margin&#45;bottom:10.0pt;line&#45;height:normal;text&#45;autospace: ideograph&#45;numeric ideograph&#45;other' align="left">&nbsp;</p>     ]]></body>
<body><![CDATA[<p style='margin&#45;bottom:12.0pt;line&#45;height:normal;' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font></p>     <p style='margin&#45;bottom:12.0pt;line&#45;height:normal;' align="left"><font face="verdana" size="2"><b><font size="3">INTRODUCCI&Oacute;N</font></b></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Con    el surgimiento y el desarrollo de la cirug&iacute;a refractiva corneal (CRC)    se han podido corregir quir&uacute;rgicamente a millones de pacientes con defectos    refractivos. Los resultados alcanzados a nivel mundial son extraordinariamente    alentadores, pues liberan de la dependencia a los usuarios de lentes o gafas    graduadas, y han mejorado as&iacute; su calidad de vida.<sup>1&#45; 6</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Con    el cursar de los a&ntilde;os comienza fisiol&oacute;gicamente a opacarse el    cristalino y a disminuir la agudeza visual en estos pacientes miopes o hiperm&eacute;tropes    a quienes se le hab&iacute;a realizado previamente una CRC donde se les modific&oacute;    la curvatura de esta; entonces, ante la necesidad de remover el cristalino y    calcular una lente intraocular (LIO) de potencia adecuada para conseguir la    emetrop&iacute;a, surge un nuevo reto a la Oftalmolog&iacute;a,<sup>1,7&#45;9</sup>    lo que motiv&oacute; a realizar una revisi&oacute;n bibliogr&aacute;fica con    el prop&oacute;sito de describir los principales m&eacute;todos descritos para    realizar el c&aacute;lculo de la LIO en estos pacientes.</font></p>     <p style='line&#45;height:normal' align="left">&nbsp;</p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b><font size="3">C&Aacute;LCULO    DE LA LENTE INTRAOCULAR</font></b></font></p>     <p style='margin&#45;bottom:12.0pt;line&#45;height:normal;' align="left"><font face="verdana" size="2">El    c&aacute;lculo de la LIO en pacientes con CRC es mucho m&aacute;s complejo,    pues adem&aacute;s de tener longitudes axiales extremas, se a&ntilde;aden factores    por la intervenci&oacute;n previa que alteran la predictibilidad del resultado    visual, con la aplicaci&oacute;n de las f&oacute;rmulas de c&aacute;lculo de    LIO existentes.<sup>10&#45;12</sup> Seg&uacute;n varios autores, las razones    son dos: un c&aacute;lculo incorrecto de la potencia corneal y una estimaci&oacute;n    incorrecta de la posici&oacute;n efectiva del lente &#91;<i>Effective Lens Position</i>    (ELP)&#93;.<sup>13 </sup></font><font face="verdana" size="2">Enti&eacute;ndase    por ELP la posici&oacute;n exacta donde va el LIO. El margen de error de la    ELP es amplio; de ah&iacute; que muchos investigadores coinciden en que el mayor    peso lo tiene la determinaci&oacute;n del poder corneal, ya que existen dificultades    para su correcta medici&oacute;n.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">La    queratometr&iacute;a (K) es el segundo factor que m&aacute;s influye, despu&eacute;s    de la longitud axial, a la hora de calcular la potencia de la LIO. La medida    correcta de la curvatura corneal es importante, pues un error de una dioptr&iacute;a    induce una desviaci&oacute;n de una dioptr&iacute;a en el poder de la LIO.<sup>14</sup>    Despu&eacute;s de una CRC la utilizaci&oacute;n del valor queratom&eacute;trico    medido, sin efectuar ninguna correcci&oacute;n, producir&aacute; un c&aacute;lculo    err&oacute;neo de la potencia de la LIO: un paciente tratado por miop&iacute;a    que sea intervenido quir&uacute;rgicamente de cataratas quedar&aacute; hiperm&eacute;trope    y al contrario, si previamente se trat&oacute; una hipermetrop&iacute;a, tras    la cirug&iacute;a de catarata quedar&aacute; miope; de ah&iacute; el valor del    poder corneal postoperatorio (Kpost).<sup>15&#45;18</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">El    resultado refractivo posquir&uacute;rgico no esperado por el paciente y el cirujano,    tras la cirug&iacute;a de cristalino, se conoce como sorpresa refractiva. Se    considera como la variaci&oacute;n de una o m&aacute;s dioptr&iacute;as con    respecto al valor esperado en la refracci&oacute;n posoperatoria.<sup>1</sup>    La alteraci&oacute;n en la relaci&oacute;n entre las superficies de la c&oacute;rnea    tras un procedimiento fotoablativo y la utilizaci&oacute;n del &iacute;ndice    queratom&eacute;trico est&aacute;ndar condicionan que la lectura queratom&eacute;trica    aportada por los querat&oacute;metros o por los top&oacute;grafos convencionales    sea inexacta, y establecen un error en el c&aacute;lculo de la ELP y de la potencia    de la c&oacute;rnea.<sup>19&#45;23</sup> Se han descrito varios m&eacute;todos    que permiten determinar correctamente la potencia de la lente a implantar, dependiendo    de los datos de los que se dispongan. En l&iacute;neas generales, hay cuatro    posibles situaciones:<sup>24,25</sup></font></p>     <div align="left">   <ul>         ]]></body>
<body><![CDATA[<li><font face="verdana" size="2">Se conoce la queratometr&iacute;a y refracci&oacute;n        preoperatorias (Kpre y Rpre) y queratometr&iacute;a y refracci&oacute;n        posoperatorias (Kpost y Rpost). La Rpost puede ser no ser fiable.</font></li>         <li><font face="verdana" size="2">No se conocen la Rpre, pero s&iacute; el        resto de los datos (Kpre, Rpost y Kpost).</font></li>         <li><font face="verdana" size="2">Se conoce la Rpre, la Rpost y la Kpost,        pero no se sabe la Kpre.</font> </li>         <li><font face="verdana" size="2">No se conoce ning&uacute;n dato anterior        a la cirug&iacute;a, s&oacute;lo se dispone de la Kpost.</font></li>       </ul> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Es    conveniente emplear varios m&eacute;todos de estimaci&oacute;n de la Kpost,    y si los resultados difieren, utilizar el valor m&aacute;s bajo en ojos miopes    y el m&aacute;s alto en ojos hiperm&eacute;tropes, excepto para los m&eacute;todos    de <i>Ferrara</i> y <i>Rosa</i>.<sup>24,25</sup> A continuaci&oacute;n se describen    algunos de ellos.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">M&Eacute;TODO    DE LA HISTORIA CL&Iacute;NICA (MHC)<sup>25,26</sup></font></p>     <p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">El    poder di&oacute;ptrico corneal posoperatorio se calcula al sustraer el cambio    en la refracci&oacute;n manifiesta en el plano corneal inducido por el procedimiento    refractivo quir&uacute;rgico de los valores corneales obtenidos antes de dicha    cirug&iacute;a:</font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2">Kpost= Kpre + SEpre &#45; SEpost.    ]]></body>
<body><![CDATA[<br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">SE        o EE: equivalente esf&eacute;rico.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">SEpre:        equivalente esf&eacute;rico preoperatorio.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">SEpost:        equivalente esf&eacute;rico posoperatorio.</font></li>       </ul> </div>     ]]></body>
<body><![CDATA[<p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2">A    continuaci&oacute;n se puede utilizar la f&oacute;rmula SRK/T con la correcci&oacute;n    doble&#45;K (Kpre y Kpost&#45;corregida) de <i>Aramberri</i>.<sup>27</sup> El    c&aacute;lculo del poder corneal a partir de la historia refractiva es el que    ha mostrado mayor exactitud en la mayor&iacute;a de los trabajos.<sup>28&#45;30</sup>    Sin embargo, este m&eacute;todo tiene aplicaci&oacute;n limitada, ya que requiere    conocer la refracci&oacute;n y la queratometr&iacute;a previa a la cirug&iacute;a    refractiva y esto no siempre es posible, pues generalmente transcurren a&ntilde;os    o incluso d&eacute;cadas entre ambas intervenciones. Adem&aacute;s, utiliza    la refracci&oacute;n manifiesta y se puede introducir un error relacionado con    la miop&iacute;a de &iacute;ndice por la catarata.</font></p>     <p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2">M&Eacute;TODO    DOBLE&#45;K DE <i>ARAMBERRI</i> CON ESTIMACI&Oacute;N DE KPRE<sup>27,31,32</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><i>Arraberri</i>    afirma que la hipermetrop&iacute;a residual en pacientes con CRC para corregir    miop&iacute;a, es secundaria al error en el c&aacute;lculo de la posici&oacute;n    efectiva de la LIO (ELP) generado por las f&oacute;rmulas te&oacute;ricas de    tercera generaci&oacute;n, en donde se usan los valores queratom&eacute;tricos    posteriores a la cirug&iacute;a refractiva. Por lo anterior propone el m&eacute;todo    de doble K, el cual utiliza dos valores queratom&eacute;tricos (K): precirug&iacute;a    refractiva (Kpre) para el c&aacute;lculo de la ELP y poscirug&iacute;a refractiva    (Kpost) para la f&oacute;rmula de vergencia que finalmente da el poder de la    LIO. La Kpost la calcula con el m&eacute;todo de historia cl&iacute;nica. Para    poder usar este m&eacute;todo se debe contar con los valores queratom&eacute;tricos    previos a la cirug&iacute;a refractiva, lo cual no siempre es posible; de ah&iacute;    que propone sumar las dioptr&iacute;as corregidas en c&oacute;rnea a la Kpost    defina o utilizar un valor est&aacute;ndar de 43,5 &oacute; 44 D para el c&aacute;lculo    de la ELP y la Kpost definida para el c&aacute;lculo de la LIO. En estudios    recientes se ha encontrado que el m&eacute;todo de doble K produce mayor resultado    mi&oacute;pico y que es m&aacute;s exacto combinar los m&eacute;todos de doble    K con un valor de queratometr&iacute;a ajustado derivado de la topograf&iacute;a    corneal.<sup>25</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">MODIFICACI&Oacute;N    DE K TOPOQUERATOM&Eacute;TRICA<sup>25</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Kpost&#45;corregida:    K media (SimK)&#45;15 % dioptr&iacute;as corregidas. El m&eacute;todo m&aacute;s    sencillo es restar el 15 % de las dioptr&iacute;as corregidas al valor ofrecido    por el querat&oacute;metro. Si el top&oacute;grafo arroja una SimK de 37 D y    la correcci&oacute;n fue de 10 D, el valor de la Kpost ser&aacute; de 37&#45;1,5=    35,5 D.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>HAMMED</i><sup>33,34</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">El    poder refractivo efectivo ajustado (EffRpadj) se calcula al multiplicar el error    refractivo inducido por la CRC por 0,15 y sustraer este valor del medido como    poder refractivo efectivo &#91;<i>Effective refractive power</i> (EffRp)&#93;    de la topograf&iacute;a corneal: EffRpadj= EffRp &#45; (<font face="Symbol">D</font>D    * 0,15). El par&aacute;metro EffRp mide la potencia promedio de tres mil&iacute;metros    de &aacute;rea corneal central.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>KOCH&#45;WANG</i><sup>33</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Se    realiza una topograf&iacute;a corneal y se toma el valor EffRp que se multiplica    al error refractivo inducido por la cirug&iacute;a, multiplicado previamente    por 0,19: Kpost&#45;corregida= EffRp + (<font face="Symbol">D</font>D * 0,19).</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">&Iacute;NDICES    TOPOGR&Aacute;FICOS DEL ORBSCAN Y PENTACAM<sup>35,36</sup></font></p>     ]]></body>
<body><![CDATA[<p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Los    mapas que calculan la potencia paraxial son el <i>Mean Total Power</i> en el    Orbscan y el <i>True Net Power</i> en el Pentacam. Los top&oacute;grafos de    hendidura escaneada permiten medir las caras anterior y posterior de la c&oacute;rnea    y as&iacute; obtener directamente la potencia total de la c&oacute;rnea al sumar    los valores reales de ambas superficies. Por tanto, se puede evitar la asunciones    en que se basan los querat&oacute;metros y top&oacute;grafos de <i>Pl&aacute;cido</i>    (&iacute;ndice queratom&eacute;trico est&aacute;ndar 1,3375). Esta no es la    aut&eacute;ntica potencia paraxial de la c&oacute;rnea central, ya que el &iacute;ndice    de refracci&oacute;n que mejor aproxima dicho valor es de 1,3315. Sin embargo,    1,3375 es el valor que utilizan las f&oacute;rmulas de vergencia m&aacute;s    empleadas. Por tanto, los valores obtenidos con el Orbscan y el Pentacam se    convierten mediante la suma de un factor a un equivalente del &iacute;ndice    queratom&eacute;trico est&aacute;ndar (1,3375): para el Top&oacute;grafo Pentacam    &#91;<i>True net power</i> (TNP<i>)</i>&#93;ser&iacute;a +0,95 D y +1,1D para    el Orbscan &#91;<i>Mean Total Power</i> (MTP)&#93;.</font></p>     <p style='line&#45;height:normal;' align="left"><font face="verdana" size="2">El    top&oacute;grafo Pentacam, formado por una c&aacute;mara rotatoria de <i>Scheimpflug</i>    mide las superficies anterior y posterior de la c&oacute;rnea,<sup>37&#45;40</sup>    como se hab&iacute;a expresado anteriormente, e incluye <i>software</i> para    la estimaci&oacute;n del poder corneal en pacientes con cirug&iacute;a refractiva    previa, como el c&aacute;lculo de las queratometr&iacute;as (K) reales mediante    las lecturas queratom&eacute;tricas efectivas &#91;<i>Equivalent k Reading</i>    (EKR)&#93; y la estimaci&oacute;n de la K preoperatoria, a trav&eacute;s del    m&oacute;dulo <i>Holladay Report</i>. Estos datos queratom&eacute;tricos se    pueden aplicar directamente en las f&oacute;rmulas biom&eacute;tricas disponibles    para el c&aacute;lculo de la LIO sin otros ajustes.<sup>29,30,41&#45;43</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>FEIZ</i><sup>10</sup></font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2"> Kpost&#45;corregida= Kpost &#150; 0,23        * <font face="Symbol">D</font>EEpc.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;<font face="Symbol">D</font></font><font face="verdana" size="2">EEpc:        cambio de EE en plano corneal.</font></li>       </ul> </div>     <p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font><font face="verdana" size="2">M&Eacute;TODO    DEL <i>BY&#45;PASS</i> CORNEAL (<i>WALTER&#45;WAKE&#45;FOREST</i>)<sup>10</sup></font></p>     ]]></body>
<body><![CDATA[<p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Se    introduce la Kpre y la longitud axial (LA) en la f&oacute;rmula de c&aacute;lculo    con una refracci&oacute;n diana equivalente a la refracci&oacute;n antes de    la CRC, con este m&eacute;todo no se necesita la Kpost ni su estimaci&oacute;n,    sin necesidad de correcci&oacute;n de la doble&#45;K en la f&oacute;rmula de    c&aacute;lculo.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>FEIZ&#45;MANNIS</i><sup>24,25</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Se    calcula la LIO para la emetrop&iacute;a utilizando la Kpre, como si el paciente    no se hubiera realizado un procedimiento refractivo y se a&ntilde;ade el cambio    inducido por la misma en el error refractivo en plano de gafa (<font face="Symbol">D</font>D)    dividido entre 0,7: LIO post= LIO pre &#150; (<font face="Symbol">D</font>D/0,7).    En este caso no se realiza la correcci&oacute;n doble&#45;K.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DEL &Iacute;NDICE DE REFRACCI&Oacute;N DE <i>SAVINI</i><sup>24,25</sup></font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2">Kpost&#45;corregida= &#91;(1,338+ 0,0009856        *<font face="Symbol">D</font>EEsp &#45; 1)/Kpost&#45;r/1000&#93;.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2"><font face="Symbol">D</font>EEsp:        cambio en equivalente esf&eacute;rico en plano de gafa.    <br>           ]]></body>
<body><![CDATA[<br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">Kpost&#45;r:        queratometr&iacute;a en radio de curvatura (mm). A continuaci&oacute;n se        realiza la correcci&oacute;n doble&#45;K en la f&oacute;rmula de c&aacute;lculo.</font></li>       </ul> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>SPEICHER&#45;SEITZ</i><sup>44</sup></font><font face="verdana" size="2">&nbsp;</font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2"> Kpost&#45;corregida= 1,114*K central preoperatoria&#150;0,114*K        central posoperatoria.    <br>           <br>       </font></li>         <li><font face="verdana" size="2"> K central: <i>effective refractive power</i>        (EffRP) o SimK central en topograf&iacute;a.</font></li>       </ul> </div>     ]]></body>
<body><![CDATA[<p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">A    continuaci&oacute;n se realiza la correcci&oacute;n doble&#45;K en la f&oacute;rmula    de c&aacute;lculo. Este m&eacute;todo puede ser utilizado cuando la Kpre es    el &uacute;nico par&aacute;metro conocido y no hay datos fidedignos suficientes    acerca de las dioptr&iacute;as corregidas por la CR. Se considera de forma separada    la curvatura anterior y posterior de la c&oacute;rnea. La fiabilidad de este    m&eacute;todo todav&iacute;a aguarda confirmaci&oacute;n cl&iacute;nica. Te&oacute;ricamente    los resultados son prometedores si se usan en conjunto con la f&oacute;rmula    de doble&#45;K:</font></p>     <p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>BESST</i><sup>16,25</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">Basado    en las paquimetr&iacute;as y curvaturas corneales anterior y posterior obtenidas    con top&oacute;grafo Pentacam:</font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2">K BESSt (potencia corneal tras cirug&iacute;a        refractiva)= {&#91;1/rF * (n.adj &#150; n.air)&#93; + &#91;1/rB * (n.acq        &#150; n.adj)&#93; &#150; &#91;d * 1/r * (n.adj &#150; n.air) * 1/rB *(n.acq        &#150; n.adj)&#93;} * 1000.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">rF: radio curvatura anterior (mm).    <br>           <br>       </font></li>         ]]></body>
<body><![CDATA[<li><font face="verdana" size="2">rB: radio curvatura posterior (mm).    <br>           <br>       </font></li>         <li><font face="verdana" size="2">n.air= 1.    <br>           <br>       </font></li>         <li><font face="verdana" size="2"> n.vc= 1,3265.    <br>           <br>       </font></li>         <li><font face="verdana" size="2"> n.CCT= n.vc + (CCT * 0,000022).    ]]></body>
<body><![CDATA[<br>           <br>       </font></li>         <li><font face="verdana" size="2">K.conv= 337,5/rF.</font>    <br>           <br>     </li>         <li> <font face="verdana" size="2"> n.adj:</font><font face="verdana" size="2">&nbsp;    <br>           <br>       </font></li>         <li><font face="verdana" size="2"> si K.conv &lt;37,5 n.adj = n.CCT + 0,017.    <br>           ]]></body>
<body><![CDATA[<br>       </font></li>         <li><font face="verdana" size="2"> si K.conv &lt;41,44 n.adj = n.CCT.    <br>           <br>       </font></li>         <li><font face="verdana" size="2"> si K.conv &lt;45 n.adj= n.CCT &#45; 0,015.</font>    <br>           <br>     </li>         <li><font face="verdana" size="2"> n.acq= 1,336.</font></li>       </ul>   <ul>         <li><font face="verdana" size="2">&nbsp;d= d.cct/n.vc.    ]]></body>
<body><![CDATA[<br>       </font><font face="verdana" size="2">&nbsp;</font></li>         <li><font face="verdana" size="2">d.cct= CCT/1000000.</font></li>       </ul> </div>     <p style=';left:45.75pt;line&#45;height:normal' align="left"><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">A    continuaci&oacute;n se realiza la correcci&oacute;n doble&#45;K en la f&oacute;rmula    de c&aacute;lculo.</font></p>     <p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font><font face="verdana" size="2">UTILIZACI&Oacute;N    DE FACTORES CORRECTORES</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Es    el m&eacute;todo m&aacute;s sencillo, pero no exento de error. Se puede utilizar    el nomograma de <i>Feiz&#45;Mannis</i>,<sup>45</sup> que calcula la potencia    de la LIO seg&uacute;n el cambio producido en EE o el nomograma de Koch, que    se calcula dicha potencia seg&uacute;n las dioptr&iacute;as corregidas y la    longitud axial.<sup>46</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    REFRACTIVO DE <i>SHAMMAS</i><sup>47</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">La    f&oacute;rmula de Shammas es una alternativa si la falta de datos impide el    uso de la doble K o el m&eacute;todo de la historia cl&iacute;nica,<sup>28</sup>    la cual es obtenida por regresi&oacute;n lineal para convertir la K medida en    un equivalente de la K calculada por el m&eacute;todo de historia cl&iacute;nica:    Kpost&#45;corregida= 1,14 * Kpost &#150; 6,8.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>JARADE</i> (CORRECCI&Oacute;N DE &Iacute;NDICE REFRACTIVO)<sup>48</sup></font></p>     <div align="left">   <ul>         ]]></body>
<body><![CDATA[<li><font face="verdana" size="2">Kpost&#45;corregida= &#91;(1,3375 + 0,0014        * &#916;EEc &#150; 1)/(Kpost&#45;r/1000)&#93;.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2"><font face="Symbol">D</font>EEc:        cambio en equivalente esf&eacute;rico en plano corneal.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">Kpost&#45;r:        queratometr&iacute;a en radio de curvatura (mm).</font></li>       </ul> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font><font face="verdana" size="2">M&Eacute;TODO    DE LATKANY (M&Eacute;TODO DE CORRECCI&Oacute;N DE LA LIO)<sup>49</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Este    m&eacute;todo solo requiere conocer la Rpre, lo cual puede ser &uacute;til cuando    se dispone solamente de unas gafas viejas y no se sabe el procedimiento refractivo    realizado. Emplea un m&eacute;todo de regresi&oacute;n para corregir la potencia    calculada de la LIO, utiliza la K m&aacute;s plana y la f&oacute;rmula SRK/T.    La potencia de la LIO se corrige con la siguiente f&oacute;rmula: &#45;(0,47*    EEpre + 0,85) y se redondea hacia el 0,50 m&aacute;s cercano.</font></p>     ]]></body>
<body><![CDATA[<p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2">M&Eacute;TODO    DE <i>MASKET</i> (M&Eacute;TODO DE CORRECCI&Oacute;N DE LA LENTE INTRAOCULAR)<sup>10</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Correcci&oacute;n    LIO pos&#45;LASIK= (&#150;0,326 * &#916;EEc)+ 0,101. Este valor es a&ntilde;adido    al poder de la LIO calculado en pacientes que previamente experimentaron correcci&oacute;n    miope con l&aacute;ser o sustra&iacute;do en los casos de correcci&oacute;n    hipermetr&oacute;pica. Se utiliza la f&oacute;rmula Holladay&#45;I para longitud    axil (LA)&gt; 23 mm y la Hoffer&#45;Q para LA&lt; 23 mm. La SRK/T suele infracorregir.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE CAMELLIN (CORRECCI&Oacute;N DE &Iacute;NDICE REFRACTIVO)<sup>50</sup></font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2"> Kpost&#45;corregida= &#91;(1,3319 + 0,00113        * &#916;EEsp) &#150; 1&#93;/(Kpost&#45;r/1000).    <br>           <br>       </font></li>         <li><font face="verdana" size="2"><font face="Symbol">D</font>EEsp: cambio        en equivalente esf&eacute;rico en plano de gafa.    <br>           <br>       </font></li>         ]]></body>
<body><![CDATA[<li><font face="verdana" size="2">Kpost&#45;r: queratometr&iacute;a en radio        de curvatura (mm).</font></li>       </ul> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">M&Eacute;TODO    DE ROSA<sup>15</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2"><b>Refracci&oacute;n    corregida con m&eacute;todo de Rosa (Rrosa)</b>:</font><font face="verdana" size="2">&nbsp;</font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2">R rosa= R (0,0276 LA + 0,3635).    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">LA=        longitud axial; R= k/337,5.    <br>           ]]></body>
<body><![CDATA[<br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">Por        tanto, la K posoperatoria estimada &#91;Kpost (Rrosa)&#93;= 337,5/Rrosa.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">El        m&eacute;todo de Rosa utiliza solo la f&oacute;rmula SRK (SRK/T si LA&lt;=        29,4 mil&iacute;metros (mm) &oacute; SRK&#45;II si LA&gt;29,4 mm).</font><font face="verdana" size="2">&nbsp;</font></li>       </ul> </div>     <p style=';left:7.05pt;line&#45;height:normal' align="left"><font face="verdana" size="2">Otra    manera de realizar el c&aacute;lculo es:</font><font face="verdana" size="2">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2">Kpost&#45;corregida= &#91;(1,3375&#45;1)/(Kpost        * FCR)/1000&#93;.    <br>           ]]></body>
<body><![CDATA[<br>       </font></li>         <li><font face="verdana" size="2"> FCR: factor corrector de Rosa seg&uacute;n        longitud axial.</font></li>       </ul> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font><font face="verdana" size="2">M&Eacute;TODO    DE LA LENTE DE CONTACTO<sup>51</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Se    realiza una refracci&oacute;n subjetiva. A continuaci&oacute;n se coloca una    lente de contacto r&iacute;gida de polimetilmetaacr&iacute;lato (PMMA) de una    curva base (potencia) conocida y se realiza una nueva refracci&oacute;n. Si    la refracci&oacute;n no ha cambiado, la c&oacute;rnea tiene igual potencia que    la lente de contacto. Si la refracci&oacute;n es m&aacute;s mi&oacute;pica,    la lente de contacto es m&aacute;s curva (m&aacute;s potencia) que la c&oacute;rnea    y lo contrario pasar&aacute; en la hipermetrop&iacute;a. Se estima la Kpost.    El poder di&oacute;ptrico de la c&oacute;rnea se calcula como la suma de la    curva base de una lente de contacto, su poder y su refracci&oacute;n y se resta    el equivalente esf&eacute;rico sin la lente de contacto.</font></p>     <div align="left">   <ul>         <li><font face="verdana" size="2"> Kpost= B+P+Rlc&#45;Rg.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">B: curva base de la lente de contacto.    ]]></body>
<body><![CDATA[<br>           <br>       </font></li>         <li><font face="verdana" size="2">P: potencia de la lente de contacto.    <br>           <br>       </font></li>         <li><font face="verdana" size="2"> Rlc: sobrerrefracci&oacute;n con la lente        de contacto.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">Rg: refracci&oacute;n con gafa.</font></li>       </ul> </div>     ]]></body>
<body><![CDATA[<p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">En    ojos operados con l&aacute;ser exc&iacute;mer no se ha demostrado una adecuada    precisi&oacute;n.</font></p>     <p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font><font face="verdana" size="2">M&Eacute;TODO    DE MALONEY&#45;KOCH<sup>42,43,52,53</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Se    necesita una topograf&iacute;a corneal, pero no es necesario conocer la historia    refractiva previa del paciente. Se calcula el poder di&oacute;ptrico central    de la c&oacute;rnea (EffRp) y se modifica de acuerdo con la siguiente f&oacute;rmula:    Kpost= (EffRp * 1,114)&#45;6,1.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE LA ASOCIACI&Oacute;N AMERICANA DE CIRUG&Iacute;A REFRACTIVA Y CATARATAS (ASCRS)<sup>24,52</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Este    m&eacute;todo permite calcular el radio posterior de la c&oacute;rnea en funci&oacute;n    de las dioptr&iacute;as corregidas. El objetivo es cuantificar la raz&oacute;n    cara anterior/cara posterior antes y despu&eacute;s de la cirug&iacute;a. El    resultado es que esta raz&oacute;n es bastante constante en todo el rango de    c&oacute;rneas no operadas (40,55&#45;47,2):1,25 (&plusmn; 0,3) (media y desviaci&oacute;n    est&aacute;ndar). Tras la cirug&iacute;a la raz&oacute;n se hace variable. Con    un incremento proporcional a las dioptr&iacute;as corregidas, se ajusta por    una relaci&oacute;n lineal: Raz&oacute;n Ant/Post= 1,257 + 0,032 x dioptr&iacute;as    corregidas en c&oacute;rnea. Mediante esta f&oacute;rmula se puede calcular,    a partir de un radio de curvatura anterior obtenido por topograf&iacute;a o    queratometr&iacute;a, el radio de la cara posterior y a continuaci&oacute;n    la potencia total de la c&oacute;rnea.</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>SAVINI&#45;BARBONI&#45;ZANINI</i><sup>10</sup></font></p>     <p style=';left:1.0cm;line&#45;height:normal' align="left"><font face="verdana" size="2">Kpost&#45;corregida=    1,114 * Kcentral &#150; 4,98 (con K central obtenida de la topograf&iacute;a    corneal).</font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"></font><font face="verdana" size="2">M&Eacute;TODO    DE <i>FERRARA</i><sup>54</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">La    f&oacute;rmula desarrollada por <i>Ferrara</i> se basa en la correlaci&oacute;n    observada entre el cambio en el &iacute;ndice de refracci&oacute;n corneal despu&eacute;s    de cirug&iacute;a con exc&iacute;mer l&aacute;ser y la LA, como se muestra por    la f&oacute;rmula: TRI= &#45;0,0006 &times; LA<sup>2</sup> + 0,0213 &times;    LA + 1,1572<i>,</i> donde TRI es el &iacute;ndice de refracci&oacute;n te&oacute;rico.    El poder corneal puede calcularse usando la f&oacute;rmula: K= (TRI 1)/r, donde    r es la curvatura corneal dada en metros.</font></p>     <div align="left">   <ul>         ]]></body>
<body><![CDATA[<li><font face="verdana" size="2"> Kpost&#45;corregida= &#91;(&#45;0,0006        * LA<sup>2</sup> + 0,0213 * LA + 1,1572) &#45;1&#93;/(Kpost&#45;r/1000).    <br>           <br>       </font></li>         <li><font face="verdana" size="2">LA: longitud axial.    <br>           <br>       </font></li>         <li><font face="verdana" size="2">Kpost&#45;r: queratometr&iacute;a en radio        de curvatura (mm).</font><font face="verdana" size="2"></font></li>       </ul> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">ALGORITMO    DE <i>MACKOOL</i> (IMPLANTE SECUNDARIO)<sup>55</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Se    realiza la cirug&iacute;a de catarata y se deja al paciente af&aacute;quico.    En una ventana de tiempo entre el mismo d&iacute;a de la cirug&iacute;a y a    las 3 semanas se realiza el implante del LIO:</font></p>     ]]></body>
<body><![CDATA[<div align="left">   <ul>         <li><font face="verdana" size="2">LIOem= 1,75 * EEafaquia + (A &#150; 118,4).    <br>           <br>       </font></li>         <li><font face="verdana" size="2">LIOem= LIO para emetrop&iacute;a.    <br>           <br>       </font></li>         <li><font face="verdana" size="2"> EE afaquia: equivalente esf&eacute;rico        en afaquia.    <br>           <br>       </font></li>         ]]></body>
<body><![CDATA[<li><font face="verdana" size="2">&nbsp;</font><font face="verdana" size="2">A:        constante A de la lente.</font><font face="verdana" size="2"></font></li>       </ul> </div>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">M&Eacute;TODO    DE <i>IANCHULEV</i> (INTRAOPERATORIO)<sup>56</sup></font></p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2">LIOem=    2,1 * EEafaquia + (A &#150; 118,4). Consiste en realizar una refracci&oacute;n    intraoperatoria tras la extracci&oacute;n del cristalino y multiplicar dicho    valor por un factor que lo convierta al plano de lente intraocular. Ianchulev    calcula 2,1 como factor multiplicador, a diferencia de Mackool<sup>55</sup>    que utiliza 1,75. Es un m&eacute;todo atractivo por su simpleza, por evitar    errores en la medida de la longitud axial y por no necesitar datos previos del    paciente. Sin embargo hay que observar que el factor de conversi&oacute;n no    puede ser constante para todo el rango de K y que una variaci&oacute;n en la    ELP puede modificar significativamente el resultado. Sin embargo, los resultados    publicados recientemente con el Sistema ORA, que realiza una aberrometr&iacute;a    af&aacute;quica intraoperatoria, son muy buenos y hacen pensar que la regresi&oacute;n    estad&iacute;stica sobre miles de ojos con datos conocidos han permitido afinar    la precisi&oacute;n.<sup>57</sup></font></p>     <p style='' align="left"><font face="verdana" size="2">TRAZADO DE RAYOS<sup>58&#45;62</sup></font></p>     <p style='margin:0cm;margin&#45;bottom:.0001pt;text&#45;align:justify;' align="left"><font face="verdana" size="2">Existe    un <i>software</i> nuevo para el rastreo num&eacute;rico del rayo que permite    calcular el poder de la LIO (Oculix, Ingenieurb&uuml;ro der Leu, Hillerse, Alemania).    Actualmente se encuentra disponible en m&uacute;ltiples sistemas topogr&aacute;ficos.    Una aproximaci&oacute;n l&oacute;gica ante la ausencia de un m&eacute;todo &oacute;ptimo    para todos los casos es promediar el resultado de varios m&eacute;todos diferentes.    Esta es la orientaci&oacute;n del <i>Calculator</i> de la p&aacute;gina web    de la ASCRS (<a href="/www.iol.ascrs.org" target="_blank">/www.iol.ascrs.org</a>),    herramienta de uso gratuito utilizada por oftalm&oacute;logos de todo el mundo.</font></p>     
<p style='line&#45;height:normal' align="left"><font face="verdana" size="2">Por    &uacute;ltimo, cabe citar otras p&aacute;ginas webs &uacute;tiles para el c&aacute;lculo    de la LIO tras cirug&iacute;a refractiva: <a href="/www.iol.ocularmd.com" target="_blank">/www.iol.ocularmd.com</a>,    <a href="/www.eyelab.com" target="_blank">/www.eyelab.com</a>. Cada    a&ntilde;o se incorporan nuevas opciones, pero es un hecho que no existe en    la actualidad un m&eacute;todo &uacute;nico aceptado por todos, de ah&iacute;    que los cirujanos deban conocer todos estos para as&iacute; elegir de acuerdo    a su experiencia y a las posibilidades tecnol&oacute;gicas de cada centro cual    emplear.</font></p>     
<p style='line&#45;height:normal' align="left">&nbsp;</p>     <p style='line&#45;height:normal' align="left"><font face="verdana" size="2"><b>Conflictos    de intereses    <br>       ]]></body>
<body><![CDATA[<br>   </b>No se declaran por los autores.</font></p>     <p style='text&#45;align:justify;' align="left"><font face="verdana" size="2"><b>&nbsp;</b></font></p>     <p style='text&#45;align:justify;' align="left"><font face="verdana" size="2"><b><font size="3">REFERENCIAS    BIBLIOGR&Aacute;FICAS</font></b></font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">1.    Savini G, Barboni P, Zanini M. Correlation between attempted correction and    keratometric refractive index of the cornea after myopic exc&iacute;mer laser    surgery. J Refract Surg. 2007;23(5):461&#45;6.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">2.    Ali&oacute; JL. Laser refractive surgery: have we arrived? Br J Ophthalmol.    2012;96(9):1159.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">3.    Winkler C, Khoramnia R, Salgado J, Wullner C. First clinical results with a    new 200 kHz femtosecond laser system. Br J Ophthalmol. 2012;96(9):788&#45;92.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">4.    Reynolds MJ, Naroo SA, Moore T, Shah S. Exc&iacute;mer l&aacute;ser surface    ablation &#45; a review. Clin Experim Ophthalmol. 2010;38(2):168&#45;82.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">5.    Reinstein DZ, Threlfall WB, Cook R, Cremonesi E, Sutton H, Archer T. Short term    LASIK outcomes using the Technolas 217C exc&iacute;mer laser and Hansatome microkeratome    in 46 708 eyes treated between 1998 and 2001. Br J Ophthalmol. 2012;96(9):1173&#45;9.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">6.    Del Monte DW. Anatomy and physiology of the cornea. J Cataract Refract Surg.    2011;37(3):588&#45;98.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">7.    Kawamorita T, Uozato H, Kamiya K, Leon Bax, Tsutsui K, Aizawa D, Shimizu K.    Repeatability, reproducibility and agreement characteristics of rotating Scheimpflug    photography and scanning&#45;slit corneal topography for corneal power measurement.    J Cataract Refract Surg. 2009;35(1):127&#45;33.    </font></p>     <!-- ref --><p style='line&#45;height:normal;' align="left"><font face="verdana" size="2">8.    Rosa N. Corneal morphological changes after myopic excimer laser refractive    surgery. Cornea. 2011;30(2):130&#45;5.    </font></p>     <!-- ref --><p style='line&#45;height:normal;' align="left"><font face="verdana" size="2">9.    Rosa N. Analysis of photoastigmatic keratectomy with the cross&#45;cylinder    ablation. Ind J Ophthalmol. 2012;60(4):283&#45;7.    </font></p>     <!-- ref --><p style='line&#45;height:normal;' align="left"><font face="verdana" size="2">10.    P&eacute;rez EC. M&eacute;todos para determinar el poder de la lente intraocular    despu&eacute;s de cirug&iacute;a refractiva corneal. Rev Cubana Oftalmol. 2013    &#91;citado 12 de diciembre de 2013&#93;. Disponible en: <a href="http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/178/html" target="_blank">http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/178/html</a></font><!-- ref --><p align="left" style='text&#45;align:left;line&#45;height:normal; '><font face="verdana" size="2">11.    Rosa N, de Bernardo M, Lanza M. Axial eye length evaluation before and after    hyperopic photorefractive keratectomy. J Refract Surg. 2013;29(80):200.    </font></p>     <!-- ref --><p style='line&#45;height:normal;' align="left"><font face="verdana" size="2">12.    De Bernardo M, Rosa N. Diehl&#45;Miller nomogram for intraocular lens power    calculation. J Cat Refract Surg. 2013;39(11):1791.    </font></p>     <!-- ref --><p style=';left:1.0cm;line&#45;height:normal;' align="left"><font face="verdana" size="2">13.    Wang L, Shirayama M, Ma XJ, Kohnen T, Koch DD. Optimizing intraocular lens power    calculations in eyes with axial lengths above 25,0 mm. J Cataract Refract Surg.    2011;37(11):2018&#45;27.    </font></p>     <!-- ref --><p style='line&#45;height:normal;' align="left"><font face="verdana" size="2">14.    Mesa JC, Mart&iacute; T, Arruga J. C&aacute;lculo de la potencia de la lente    intraocular en situaciones especiales. Ann Oftalmol. 2008;16(2):68&#45;89.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">15.    Rosa N, Capaso L, Romano A. A new method of calculating intraocular lens power    after photorefractive keratectomy. J Cataract Refract Surg. 2002;18(6):720&#45;4.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">16.    Borasio E, Stevens E, Smith GT. Estimation of true corneal power after keratorefractive    surgery in eyes requiring cataract surgery: BESSt formula. J Cat Refract Surg.    2006;32(12):2004&#45;14.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">17.    Masket S, Masket SE. Simple regressi&oacute;n formula for intraocular lens power    adjustment in eyes requiring cataract surgery after exc&iacute;mer laser photoablation.    J Cataract Refract Surg. 2006;32(3):430&#45;4.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">18.    De Bernardo M, Capasso L, Rosa N. Algorithm for the estimation of the corneal    power in eyes with previous myopic laser refractive surgery. Cornea. 2014;33(6):5.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">19.    Rosa N, Capasso L, de Bernardo M, Lanza M. IOL power calculation after refractive    surgery. Ophthalmology. 2011;118(11):2309-11.    </font></p>     ]]></body>
<body><![CDATA[<p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">20.    Rosa N. Intraocular lens power calculation: a challenging case. Optometry &amp;    Vision Science. 2014;91:29&#45;31.</font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">21.    Rosa N. Reliability of the IOLMaster in measuring corneal power changes after    hyperopic photorefractive keratectomy. J Refract Surg. 2011;27(4):293&#45;98.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">22.    Konstantopoulos A, Hossain P, Anderson DF. Recent advances in ophthalmic anterior    segment imaging: a new era for ophthalmic diagnosis? Br J Ophthalmol. 2007;91(4):551&#45;7.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">23.    Ortega L. Modificaciones de la curvatura posterior corneal despu&eacute;s de    la cirug&iacute;a refractiva l&aacute;ser. Rev Cubana Oftalmol. 2011;24(1):111&#45;23.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">24.    Mesa JC, Porta J, Cbir&oacute; I, Am&iacute;as V, Rouras A. C&aacute;lculo biom&eacute;trico    tras cirug&iacute;a refractiva. Superficie ocular. Rev Laborat Thea. 2010;37(3):747&#45;8.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">25.    Mesa JC, Ruiz CL. El c&aacute;lculo de la lente intraocular tras cirug&iacute;a    foto&#45;refractiva corneal. Revisi&oacute;n de la literatura. Arch Soc Esp    Oftalmol. 2009;84(6):283&#45;92.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">26.    Ortega JG, Freidell H, Kwitko S, Lu LW, Zacharias W, S&aacute;chez JC. Cu&aacute;l    es la t&eacute;cnica de elecci&oacute;n para el c&aacute;lculo del LIO post&#45;cirug&iacute;a    refractiva. Noticiero ALACCSA&#45;R/Diciembre 2011 &#91;citado 10 enero 2012&#93;.    Disponible en: <a href="http://www.alaccsa.com/noticiero_diciembre_11.htm" target="_blank">http://www.alaccsa.com/noticiero_diciembre_11.htm</a></font><!-- ref --><p style='margin:0cm;margin&#45;bottom:.0001pt; text&#45;align:justify;line&#45;height:normal' align="left"><font face="verdana" size="2">27.    Aramberri J. Intraocular lens power calculation after corneal refractive surgery:    double&#45;K method. J Cataract Refract Surg. 2003;29(11):2063&#45;8.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">28.    Prado A, Cama JT, Sosa SP, Nava NG. C&oacute;mo evitar la sorpresa refractiva.    C&aacute;lculo del poder di&oacute;ptrico de lentes intraoculares en casos especiales.    Rev Mex Oftalmol. 2010;84(1):39&#45;48.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">29.    Cuan Y, P&eacute;rez E, Montero E, Santiesteban I, Ortega L, C&aacute;rdenas    T. Utilidad del Top&oacute;grafo Pentacam para medir el poder corneal despu&eacute;s    de cirug&iacute;a refractiva con exc&iacute;mer l&aacute;ser. Rev Cubana Oftalmol.    2010;23(Sup. 1):513&#45;21.    </font></p>     <!-- ref --><p style=';left:1.0cm;line&#45;height:normal; text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">30.    C&aacute;rdenas T, Torres R, Corcho Y, Capote A, Cuan Y, Hern&aacute;ndez I.    Sistema Scheimpflug Top&oacute;grafo Pentacam <i>vs</i>. m&eacute;todo de la    historia cl&iacute;nica en hiperm&eacute;tropes con cirug&iacute;a refractiva    previa. Rev Cubana Oftalmol. 2013 &#91;citado junio 2013&#93;;26(1). &nbsp;Disponible    en: <a href="http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/173" target="_blank">http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/173</a></font><!-- ref --><p style=';left:1.0cm;line&#45;height:normal; text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">31.    Saiki M. Modified double&#45;K method for intraocular lens power calculation    after excimer laser corneal refractive surgery. J Cataract Refract Surg. 2013;39(4):556&#45;62.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">32.    Aramberri J. C&aacute;lculo de la lente intraocular tras cirug&iacute;a refractiva    corneal. En: Ali&oacute; J, Rodr&iacute;guez&#45;Prats J. Buscando la excelencia    en la cirug&iacute;a de la catarata. Barcelona, Editorial Glosa; 2006. p. 179&#45;91.    </font></p>     <!-- ref --><p style='margin:0cm;margin&#45;bottom:.0001pt; text&#45;align:justify;line&#45;height:normal' align="left"><font face="verdana" size="2">33.    Koch D, Wang L. Calculating IOL power in eyes that have had refractive surgery.    J Cataract Refract Surgery. 2003;29(11):2039&#45;42.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">34.    Hamed A, Wang L, Misra M, Koch C. A comparative analysis of five methods of    determining corneal refractive power in eyes that have undergone myopic laser    in situ keratomileusis. Ophthalmology. 2002;109(4):651&#45;8.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">35.    Savini G, Barboni P, Profazio V, Zanini M, Hoffer KJ. Corneal power measurements    with the Top&oacute;grafo Pentacam Scheimpflug camera after myopic exc&iacute;mer    laser surgery. J Cataract Refract Surg. 2008;34(5):809&#45;13.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">36.    Jim&eacute;nez G. C&aacute;lculo de lente intraocular en pacientes con cirug&iacute;a    refractiva previa. Rev Mex Oftalmol. 2007;81(3):134&#45;7.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">37.    Dom&iacute;nguez M. Beneficios del sistema Scheimpflug en glaucoma. Rev Cubana    Oftalmol. 2012 &#91;citado 7 de noviembre de 2014&#93;. Disponible en: <a href="http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762012000300011&lng=es&nrm=iso&tlng=es" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864&#45;21762012000300011&amp;lng=es&amp;nrm=iso&amp;tlng=es</a></font><!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">38.    Miranda I. Comparaci&oacute;n de los valores del espesor corneal central seg&uacute;n    los equipos Lenstar, Galilei y Pentacam. Rev Cubana Oftalmol. 2012;25(1):65&#45;71.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">39.    Hern&aacute;ndez I. Cuantificaci&oacute;n objetiva de la opacidad de la c&aacute;psula    posterior mediante tomogramas Scheimpflug del Pentacam. Rev Cubana Oftalmol.    2011;24(2):208&#45;19.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">40.    Tirado OM, Hern&aacute;ndez A. Top&oacute;grafos de elevaci&oacute;n en el diagn&oacute;stico    del queratocono. Rev Cubana Oftalmol. 2011;24(2):364&#45;73.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">41.    Shammas HJ, Hoffer KJ, Shammas MC. Scheimpflug photography keratometry readings    for routine intraocular lens power calculation. J Cataract Refract Surg. 2009;35(2):330&#45;4.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">42.    C&aacute;rdenas T, Ravelo W, Capote A, P&eacute;rez EC, Cuan Y, Hern&aacute;ndez    I. Poder corneal poscirug&iacute;a fotoablativa en miopes. Sistema Scheimpflug    Top&oacute;grafo Pentacam <i>vs</i>. M&eacute;todo de Maloney. Rev Cubana Oftalmol.    2014 &#91;citado marzo 2014&#93;;27(1). &nbsp;Disponible en: <a href="http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/229/html" target="_blank">http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/229/html</a></font><!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">43.    C&aacute;rdenas T, Vinardell S, Capote A, P&eacute;rez EC, Cuan Y, Cruz D. Estudio    queratom&eacute;trico por Top&oacute;grafo Pentacam en hipermetr&oacute;pes    con cirug&iacute;a l&aacute;ser <i>vs</i>. M&eacute;todo de Maloney. Rev Cubana    Oftalmol. 2014 &#91;citado marzo 2014&#93;;27(1). &nbsp;Disponible en: <a href="http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/230/html" target="_blank">http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/230/html</a></font><!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">44.    Speicher C, Seitz J. Cataract surgery in patients with prior refractive surgery.    Curr opin Ophthalmol. 2003;14(1):44&#45;53.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">45.    Feiz V, Moshirfar M, Mannis M, Reilly C, Garcia&#45;Ferrer F. Nomogram&#45;based    intraocular lens power adjustment after myopic photokeratectomy and Lasik. Ophtahlmology.    2005;112(8):1381&#45;7.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">46.    Saiki M. A new central&#45;peripheral corneal curvature method for intraocular    lens power calculation after excimer laser refractive surgery. Act Ophthalmol.    2013;91(2):e133&#45;9.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">47.    Shammas H, Shamas M, Garabet A, Kim J, Shammas A, LaBree L. Correcting the corneal    power measurements for intraocular lens power calculations after myopic laser    <i>in situ</i> keratomileusis. Am J Ophthalmol. 2003;136(3):426&#45;32.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">48.    Jarade EF, Abinader FC, Tabbara KF. Intraocular lens power calculation following    LASIK. Invest ophthalmol vis sci. 2002;43:41&#45;3.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">49.    Latkany R, Chokshi A, Speader M, Abramson I, Solowitz B. Intraocular lens calculations    after refractive surgery. J Cat Refrac Surg. 2005;31(3):562&#45;70.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">50.    Camellin M, Calossi A. A new formula for intraocular lens power calculation    after refractive corneal surgery. J Refract Surg. 2006;22(2):187&#45;99.    </font></p>     <!-- ref --><p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt; text&#45;align:justify;line&#45;height:normal' align="left"><font face="verdana" size="2">51.    Haigis W. Corneal power alter refractive surgery for myopa: contact lens method.    J Cataract Refract Surgery 2003;29(7):1397&#45;411.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">52.    Koch DD, Liu JF, Hyde LL, Rock RL, Emery JM. Refractive complications of cataract    surgery after radial keratotomy. Am J Ophthalmol. 1989;108(6):676&#45;82.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">53.    P&eacute;rez EC, Aguilar Y, C&aacute;rdenas T, Men&eacute;ndez AM, Rodr&iacute;guez    B. Aplicaci&oacute;n del m&eacute;todo de Maloney en el c&aacute;lculo de la    lente intraocular despu&eacute;s de cirug&iacute;a refractiva corneal. Rev Cubana    Oftalmol. 2010;23(Suppl.1):470&#45;9.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">54.    Ferrara G, Cennamo G, Marotta G. New formula to calculate IOL power. J Cataract    Refract Surg. 2004;20(5):465&#45;71.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">55.    Mackool RJ, Wilson K, Mackool R. Intraocular lens power calculation after laser    <i>in situ</i> keratomieleusis: apahakic refraction technique. J Cataract Refract    Surg. 2006;32(3):435&#45;7.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">56.    Ianchulev T, Salz J, Hoffer K, Albini T, Hsu H, Labree L. Intraoperatory optical    biometry for intraocular lens power estimation without axial length and keratometry    measurements. J Cataract Refract Surg. 2005;31(8):1530&#45;6.    </font></p>     <!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">57.    Ianchulev T. Intraoperative refractive biometry for predicting intraocular lens    power calculation after prior myopic refractive surgery. Ophthalmology. 2014;121(1):56&#45;60.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p style='line&#45;height:normal' align="left"><font face="verdana" size="2">58.    Savini G, Bedei A, Barboni P, Ducoli P, Hoffer KJ. Intraocular lens power calculation    by Ray&#45;Tracing after myopic excimer laser surgery. Am J Ophthalmol. 2014;157(1):150&#45;3.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">59.    Hoffmann P, Wahl J, Preussner PR.&nbsp; Accuracy of intraocular lens calculation    with ray tracing. J Refract Surg. 2012;28(9):650&#45;5.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">60.    Minami K. Ray&#45;tracing intraocular lens power calculation using anterior    segment optical coherence tomography measurements. J Cataract Refract Surg.    2012;38(10):1758&#45;63.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">61.    Savini G, Calossi A, Camellin M, Carones F, Fantozzi M, Hoffer KJ. Corneal ray    tracing <i>versus</i> simulated keratometry for estimating corneal power changes    after excimer laser surgery. J Cataract Refract Surg. 2014;40(7):1109&#45;15.    </font></p>     <!-- ref --><p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">62.    Saiki M. Ray tracing software for intraocular lens power calculation after corneal    exc&iacute;mer laser surgery. Jpn J Ophthalmol. 2014;58(3):276&#45;81.    </font></p>     ]]></body>
<body><![CDATA[<p style='line&#45;height:normal' align="left"><font face="verdana" size="2">&nbsp;</font></p>     <p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2"></font></p>     <p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">Recibido:    26 de octubre de 2015.    <br>   Aprobado: 14 de diciembre de 2015.</font></p>     <p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</font></p>     <p style='line&#45;height:normal;text&#45;autospace:ideograph&#45;numeric ideograph&#45;other' align="left"><font face="verdana" size="2">&nbsp;</font></p>     <div align="left"><font face="verdana" size="2"></font><font face="verdana" size="2"><i>Taim&iacute;    C&aacute;rdenas D&iacute;az</i>. Instituto Cubano de Oftalmolog&iacute;a "Ram&oacute;n    Pando Ferrer". Ave. 76 No. 3104 entre 31 y 41 Marianao, La Habana, Cuba. Correo    electr&oacute;nico: <a href="mailto:taimicar@infomed.sld.cu">taimicar@infomed.sld.cu</a></font>  </div>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Barboni]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Zanini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correlation between attempted correction and keratometric refractive index of the cornea after myopic excímer laser surgery]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2007</year>
<volume>23</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>461-6</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alió]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Laser refractive surgery: have we arrived?]]></article-title>
<source><![CDATA[Br J Ophthalmol]]></source>
<year>2012</year>
<volume>96</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1159</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Winkler]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Khoramnia]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Salgado]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Wullner]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[First clinical results with a new 200 kHz femtosecond laser system]]></article-title>
<source><![CDATA[Br J Ophthalmol]]></source>
<year>2012</year>
<volume>96</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>788-92</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reynolds]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Naroo]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Moore]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Excímer láser surface ablation - a review]]></article-title>
<source><![CDATA[Clin Experim Ophthalmol]]></source>
<year>2010</year>
<volume>38</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>168-82</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Reinstein]]></surname>
<given-names><![CDATA[DZ]]></given-names>
</name>
<name>
<surname><![CDATA[Threlfall]]></surname>
<given-names><![CDATA[WB]]></given-names>
</name>
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Cremonesi]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Sutton]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Archer]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Short term LASIK outcomes using the Technolas 217C excímer laser and Hansatome microkeratome in 46 708 eyes treated between 1998 and 2001]]></article-title>
<source><![CDATA[Br J Ophthalmol]]></source>
<year>2012</year>
<volume>96</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1173-9</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Del Monte]]></surname>
<given-names><![CDATA[DW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Anatomy and physiology of the cornea]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2011</year>
<volume>37</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>588-98</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kawamorita]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Uozato]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kamiya]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Leon]]></surname>
<given-names><![CDATA[Bax]]></given-names>
</name>
<name>
<surname><![CDATA[Tsutsui]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Aizawa]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Shimizu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Repeatability, reproducibility and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2009</year>
<volume>35</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>127-33</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal morphological changes after myopic excimer laser refractive surgery]]></article-title>
<source><![CDATA[Cornea]]></source>
<year>2011</year>
<volume>30</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>130-5</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of photoastigmatic keratectomy with the cross-cylinder ablation]]></article-title>
<source><![CDATA[Ind J Ophthalmol]]></source>
<year>2012</year>
<volume>60</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>283-7</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[EC]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Métodos para determinar el poder de la lente intraocular después de cirugía refractiva corneal]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2013</year>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[de Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Lanza]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Axial eye length evaluation before and after hyperopic photorefractive keratectomy]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2013</year>
<volume>29</volume>
<numero>80</numero>
<issue>80</issue>
<page-range>200</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diehl-Miller nomogram for intraocular lens power calculation]]></article-title>
<source><![CDATA[J Cat Refract Surg]]></source>
<year>2013</year>
<volume>39</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1791</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Shirayama]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[XJ]]></given-names>
</name>
<name>
<surname><![CDATA[Kohnen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optimizing intraocular lens power calculations in eyes with axial lengths above 25,0 mm]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2011</year>
<volume>37</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2018-27</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mesa]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Martí]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Arruga]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de la potencia de la lente intraocular en situaciones especiales]]></article-title>
<source><![CDATA[Ann Oftalmol]]></source>
<year>2008</year>
<volume>16</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>68-89</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Capaso]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Romano]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new method of calculating intraocular lens power after photorefractive keratectomy]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2002</year>
<volume>18</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>720-4</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Borasio]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Stevens]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[GT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formula]]></article-title>
<source><![CDATA[J Cat Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>2004-14</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Masket]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Masket]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simple regressión formula for intraocular lens power adjustment in eyes requiring cataract surgery after excímer laser photoablation]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>430-4</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Capasso]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Algorithm for the estimation of the corneal power in eyes with previous myopic laser refractive surgery]]></article-title>
<source><![CDATA[Cornea]]></source>
<year>2014</year>
<volume>33</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>5</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Capasso]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[de Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Lanza]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[IOL power calculation after refractive surgery]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2011</year>
<volume>118</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2309-11</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation: a challenging case]]></article-title>
<source><![CDATA[Optometry & amp; Vision Science]]></source>
<year>2014</year>
<volume>91</volume>
<page-range>29-31</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability of the IOLMaster in measuring corneal power changes after hyperopic photorefractive keratectomy]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2011</year>
<volume>27</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>293-98</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Konstantopoulos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hossain]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[DF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Recent advances in ophthalmic anterior segment imaging: a new era for ophthalmic diagnosis?]]></article-title>
<source><![CDATA[Br J Ophthalmol]]></source>
<year>2007</year>
<volume>91</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>551-7</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Modificaciones de la curvatura posterior corneal después de la cirugía refractiva láser]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2011</year>
<volume>24</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>111-23</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mesa]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Porta]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Cbiró]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Amías]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Rouras]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo biométrico tras cirugía refractiva: Superficie ocular]]></article-title>
<source><![CDATA[Rev Laborat Thea]]></source>
<year>2010</year>
<volume>37</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>747-8</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mesa]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[El cálculo de la lente intraocular tras cirugía foto-refractiva corneal: Revisión de la literatura]]></article-title>
<source><![CDATA[Arch Soc Esp Oftalmol]]></source>
<year>2009</year>
<volume>84</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>283-92</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Freidell]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kwitko]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[LW]]></given-names>
</name>
<name>
<surname><![CDATA[Zacharias]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Sáchez]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cuál es la técnica de elección para el cálculo del LIO post-cirugía refractiva]]></article-title>
<source><![CDATA[Noticiero ALACCSA-R/]]></source>
<year>Dici</year>
<month>em</month>
<day>br</day>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aramberri]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation after corneal refractive surgery: double-K method]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2003</year>
<volume>29</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2063-8</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Prado]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cama]]></surname>
<given-names><![CDATA[JT]]></given-names>
</name>
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Nava]]></surname>
<given-names><![CDATA[NG]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cómo evitar la sorpresa refractiva: Cálculo del poder dióptrico de lentes intraoculares en casos especiales]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>2010</year>
<volume>84</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>39-48</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cuan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Montero]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Santiesteban]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Utilidad del Topógrafo Pentacam para medir el poder corneal después de cirugía refractiva con excímer láser]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2010</year>
<volume>23</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>513-21</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Corcho]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Capote]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cuan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Sistema Scheimpflug Topógrafo Pentacam vs. método de la historia clínica en hipermétropes con cirugía refractiva previa]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2013</year>
<volume>26</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saiki]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Modified double-K method for intraocular lens power calculation after excimer laser corneal refractive surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2013</year>
<volume>39</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>556-62</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aramberri]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de la lente intraocular tras cirugía refractiva corneal]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Alió]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez-Prats]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Buscando la excelencia en la cirugía de la catarata]]></source>
<year>2006</year>
<page-range>179-91</page-range><publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Glosa]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Calculating IOL power in eyes that have had refractive surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surgery]]></source>
<year>2003</year>
<volume>29</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2039-42</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamed]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Misra]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative analysis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2002</year>
<volume>109</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>651-8</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Barboni]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Profazio]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Zanini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal power measurements with the Topógrafo Pentacam Scheimpflug camera after myopic excímer laser surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2008</year>
<volume>34</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>809-13</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiménez]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de lente intraocular en pacientes con cirugía refractiva previa]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>2007</year>
<volume>81</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>134-7</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Domínguez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Beneficios del sistema Scheimpflug en glaucoma]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2012</year>
</nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miranda]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Comparación de los valores del espesor corneal central según los equipos Lenstar, Galilei y Pentacam]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2012</year>
<volume>25</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>65-71</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cuantificación objetiva de la opacidad de la cápsula posterior mediante tomogramas Scheimpflug del Pentacam]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2011</year>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>208-19</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tirado]]></surname>
<given-names><![CDATA[OM]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Topógrafos de elevación en el diagnóstico del queratocono]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2011</year>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>364-73</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Scheimpflug photography keratometry readings for routine intraocular lens power calculation]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2009</year>
<volume>35</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>330-4</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ravelo]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Capote]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[EC]]></given-names>
</name>
<name>
<surname><![CDATA[Cuan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Poder corneal poscirugía fotoablativa en miopes: Sistema Scheimpflug Topógrafo Pentacam vs. Método de Maloney]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2014</year>
<volume>27</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Vinardell]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Capote]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[EC]]></given-names>
</name>
<name>
<surname><![CDATA[Cuan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Cruz]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estudio queratométrico por Topógrafo Pentacam en hipermetrópes con cirugía láser vs. Método de Maloney]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2014</year>
<volume>27</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Speicher]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Seitz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cataract surgery in patients with prior refractive surgery]]></article-title>
<source><![CDATA[Curr opin Ophthalmol]]></source>
<year>2003</year>
<volume>14</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>44-53</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feiz]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Moshirfar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Mannis]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Reilly]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Garcia-Ferrer]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nomogram-based intraocular lens power adjustment after myopic photokeratectomy and Lasik]]></article-title>
<source><![CDATA[Ophtahlmology]]></source>
<year>2005</year>
<volume>112</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1381-7</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saiki]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new central-peripheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgery]]></article-title>
<source><![CDATA[Act Ophthalmol]]></source>
<year>2013</year>
<volume>91</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>e133-9</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Shamas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Garabet]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[LaBree]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2003</year>
<volume>136</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>426-32</page-range></nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jarade]]></surname>
<given-names><![CDATA[EF]]></given-names>
</name>
<name>
<surname><![CDATA[Abinader]]></surname>
<given-names><![CDATA[FC]]></given-names>
</name>
<name>
<surname><![CDATA[Tabbara]]></surname>
<given-names><![CDATA[KF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation following LASIK]]></article-title>
<source><![CDATA[Invest ophthalmol vis sci]]></source>
<year>2002</year>
<volume>43</volume>
<page-range>41-3</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Latkany]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Chokshi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Speader]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Abramson]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Solowitz]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens calculations after refractive surgery]]></article-title>
<source><![CDATA[J Cat Refrac Surg]]></source>
<year>2005</year>
<volume>31</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>562-70</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Camellin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Calossi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new formula for intraocular lens power calculation after refractive corneal surgery]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2006</year>
<volume>22</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>187-99</page-range></nlm-citation>
</ref>
<ref id="B51">
<label>51</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haigis]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal power alter refractive surgery for myopa: contact lens method]]></article-title>
<source><![CDATA[J Cataract Refract Surgery]]></source>
<year>2003</year>
<volume>29</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1397-411</page-range></nlm-citation>
</ref>
<ref id="B52">
<label>52</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Hyde]]></surname>
<given-names><![CDATA[LL]]></given-names>
</name>
<name>
<surname><![CDATA[Rock]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Emery]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Refractive complications of cataract surgery after radial keratotomy]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>1989</year>
<volume>108</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>676-82</page-range></nlm-citation>
</ref>
<ref id="B53">
<label>53</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[EC]]></given-names>
</name>
<name>
<surname><![CDATA[Aguilar]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Menéndez]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Aplicación del método de Maloney en el cálculo de la lente intraocular después de cirugía refractiva corneal]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2010</year>
<volume>23</volume>
<numero>^s1</numero>
<issue>^s1</issue>
<supplement>1</supplement>
<page-range>470-9</page-range></nlm-citation>
</ref>
<ref id="B54">
<label>54</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ferrara]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Cennamo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Marotta]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New formula to calculate IOL power]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2004</year>
<volume>20</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>465-71</page-range></nlm-citation>
</ref>
<ref id="B55">
<label>55</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mackool]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Wilson]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Mackool]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation after laser in situ keratomieleusis: apahakic refraction technique]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>435-7</page-range></nlm-citation>
</ref>
<ref id="B56">
<label>56</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ianchulev]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Salz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Albini]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hsu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Labree]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraoperatory optical biometry for intraocular lens power estimation without axial length and keratometry measurements]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2005</year>
<volume>31</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1530-6</page-range></nlm-citation>
</ref>
<ref id="B57">
<label>57</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ianchulev]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraoperative refractive biometry for predicting intraocular lens power calculation after prior myopic refractive surgery]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2014</year>
<volume>121</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>56-60</page-range></nlm-citation>
</ref>
<ref id="B58">
<label>58</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Bedei]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Barboni]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ducoli]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation by Ray-Tracing after myopic excimer laser surgery]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2014</year>
<volume>157</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>150-3</page-range></nlm-citation>
</ref>
<ref id="B59">
<label>59</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hoffmann]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Wahl]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Preussner]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accuracy of intraocular lens calculation with ray tracing]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2012</year>
<volume>28</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>650-5</page-range></nlm-citation>
</ref>
<ref id="B60">
<label>60</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Minami]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ray-tracing intraocular lens power calculation using anterior segment optical coherence tomography measurements]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2012</year>
<volume>38</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1758-63</page-range></nlm-citation>
</ref>
<ref id="B61">
<label>61</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Calossi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Camellin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Carones]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Fantozzi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2014</year>
<volume>40</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1109-15</page-range></nlm-citation>
</ref>
<ref id="B62">
<label>62</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saiki]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ray tracing software for intraocular lens power calculation after corneal excímer laser surgery]]></article-title>
<source><![CDATA[Jpn J Ophthalmol]]></source>
<year>2014</year>
<volume>58</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>276-81</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>