<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1684-1859</journal-id>
<journal-title><![CDATA[Revista Cubana de Informática Médica]]></journal-title>
<abbrev-journal-title><![CDATA[RCIM]]></abbrev-journal-title>
<issn>1684-1859</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Ciencias Médicas de La Habana]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1684-18592018000100005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Algoritmo para la detección de puntos clínicos de interés de la onda de pulso arterial]]></article-title>
<article-title xml:lang="en"><![CDATA[Algorithm for the detection of clinical points of interest of the arterial pulse wave]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Carrazana-Escalona]]></surname>
<given-names><![CDATA[Ramón]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ricardo-Ferro]]></surname>
<given-names><![CDATA[Beatriz Taimy]]></given-names>
</name>
<xref ref-type="aff" rid="A2"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fernández-de la Vara Prieto]]></surname>
<given-names><![CDATA[Reinier Ramón]]></given-names>
</name>
<xref ref-type="aff" rid="A2"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sánchez-Hechavarría]]></surname>
<given-names><![CDATA[Miguel Enrique]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
</contrib-group>
<aff id="AA1">
<institution><![CDATA[,Universidad de Ciencias Médicas de Santiago de Cuba  ]]></institution>
<addr-line><![CDATA[Santiago de Cuba ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="AA2">
<institution><![CDATA[,Universidad de Oriente Centro de Biofísica Médica ]]></institution>
<addr-line><![CDATA[Santiago de Cuba ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2018</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2018</year>
</pub-date>
<volume>10</volume>
<numero>1</numero>
<fpage>40</fpage>
<lpage>48</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1684-18592018000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1684-18592018000100005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1684-18592018000100005&amp;lng=en&amp;nrm=iso"></self-uri><kwd-group>
<kwd lng="es"><![CDATA[onda de pulso arterial]]></kwd>
<kwd lng="es"><![CDATA[inicio]]></kwd>
<kwd lng="es"><![CDATA[pico sistólico]]></kwd>
<kwd lng="es"><![CDATA[dicrotismo]]></kwd>
<kwd lng="es"><![CDATA[pico diastólico]]></kwd>
<kwd lng="es"><![CDATA[algoritmo de detección]]></kwd>
<kwd lng="en"><![CDATA[arterial pulse wave]]></kwd>
<kwd lng="en"><![CDATA[onset]]></kwd>
<kwd lng="en"><![CDATA[systolic peak]]></kwd>
<kwd lng="en"><![CDATA[dicrotic]]></kwd>
<kwd lng="en"><![CDATA[diastolic peak]]></kwd>
<kwd lng="en"><![CDATA[detection algorithm]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p class=authorinfo align=right style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;align:right'><font size="2" face="Verdana"><b>TRABAJOS    ORIGINALES</b></font></p>     <p class=authorinfo align=right style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:right'>&nbsp;</p>     <p class=authorinfo align=right style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:right'>&nbsp;</p>     <p class=authorinfo align=center style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:center'><font face="verdana" size="4"><b>Algoritmo    para la detecci&oacute;n de puntos cl&iacute;nicos de inter&eacute;s de la onda    de pulso arterial</b></font></p>     <p class=authorinfo align=center style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:center'>&nbsp;</p>     <p class=authorinfo align=center style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:center'><font face="verdana" size="3"><b>Algorithm    for the detection of clinical points of interest of the arterial pulse wave</b></font></p>     <p class=authorinfo style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt'><font face="verdana" size="2"><b>&nbsp;</b></font></p>    <p class=authorinfo align=left style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;align:left'><font face="verdana" size="2"><b>&nbsp;</b></font></p>     <p class=authorinfo align=left style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;align:left'><font face="verdana" size="2"><b>Ram&oacute;n    Carrazana&#45;Escalona<sup>I    <br>   </sup>Beatriz Taimy Ricardo&#45;Ferro<sup>II    ]]></body>
<body><![CDATA[<br></sup>Reinier Ram&oacute;n Fern&aacute;ndez&#45;de la Vara Prieto<sup>II </sup>&nbsp;    <br>Miguel Enrique S&aacute;nchez&#45;Hechavarr&iacute;a<sup>I</sup></b></font></p>    <p class=authorinfo align=left style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;align:left'><font face="verdana" size="2"><b>&nbsp;</b></font></p>     <p class=abstract align=left style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:left;text-indent:0cm'><font face="verdana" size="2"><sup>I    </sup>Facultad de Medicina 1. Universidad de Ciencias M&eacute;dicas de Santiago    de Cuba. Santiago de Cuba. Cuba. E&#45;mail: <a href="mailto:miguel.sanchez@sierra.scu.sld.cu">miguel.sanchez@sierra.scu.sld.cu</a>    <br>   </font><font face="verdana" size="2"><sup>II</sup> Centro de Biof&iacute;sica    M&eacute;dica. Universidad de Oriente. Santiago de Cuba. Cuba.</font></p>     <p class=abstract align=left style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:left;text-indent:0cm'>&nbsp;</p>     <p class=abstract align=left style='margin-bottom:0cm;margin-bottom:.0001pt;text-align:left;text-indent:0cm'>&nbsp;</p> <hr> <font face="verdana" size="2"><b>RESUMEN</b></font>      <p><font size="2" face="Verdana"><strong>Introducci&oacute;n:</strong></strong>    La aplicaci&oacute;n de m&eacute;todos para la detecci&oacute;n de puntos cl&iacute;nicos    de inter&eacute;s de la onda de pulso&nbsp; permite la obtenci&oacute;n de par&aacute;metros    como el &iacute;ndice de rigidez vascular y el de reflexi&oacute;n que facilitan    la evaluaci&oacute;n de los efectos vasculares del envejecimiento, la hipertensi&oacute;n    y la aterosclerosis. Por esto es necesaria la adecuada localizaci&oacute;n del    inicio, pico sist&oacute;lico, incisura dicrota y el pico diast&oacute;lico    de la onda de pulso arterial. </font><font face="verdana" size="2"><b>Objetivo:</b>    Desarrollar un algoritmo para la localizaci&oacute;n del inicio, pico sist&oacute;lico,    incisura dicrota y el pico diast&oacute;lico de la onda de pulso arterial. </font><font face="verdana" size="2"><b>M&eacute;todo:</b>    El algoritmo presentado utiliza la primera derivada unido a condicionales m&oacute;viles    para eliminar puntos no deseados, al igual que intervalos no confiables. El    algoritmo fue evaluado utilizando la anotaci&oacute;n de un experto, con 5 registros    de onda de pulso arterial de 5 minutos (5236 anotaciones) y&nbsp; contaminadas    a diferente relaciones se&ntilde;al ruido (15, 12 and 9 dB). </font><font face="verdana" size="2"><b>Resultados:</b>    Cuando se compar&oacute; con las anotaciones de un experto el algoritmo detecto    estos puntos fiduciales con una sensibilidad promedio, predictividad positiva    y exactitud del 100% y mostr&oacute; errores menores de 10ms. En se&ntilde;ales    de onda de pulso arterial contaminadas con ruido en ambos casos el error relativo    fue menor que 2% respecto a un periodo de muestreo de 800ms. <b>Conclusiones:</b>    el algoritmo provee una simple pero precisa detecci&oacute;n de los puntos cl&iacute;nicos    de inter&eacute;s de la onda de pulso arterial, robusto a ruido y artefactos    de movimiento que pudiera ser utilizado en la evaluaci&oacute;n del &iacute;ndice    de rigidez y de reflexi&oacute;n vascular.</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">    <br>   <b>Palabras clave:</b> onda de pulso arterial, inicio, pico sist&oacute;lico,    dicrotismo, pico diast&oacute;lico, algoritmo de detecci&oacute;n.&nbsp; </font></p> <hr> <font face="verdana" size="2"><b>ABSTRACT</b></font>      ]]></body>
<body><![CDATA[<p class=keywords style='margin-bottom:0cm;margin-bottom:.0001pt;text-indent:0cm'><font face="verdana" size="2"><strong>Introduction:</strong>    The application of methods for the detection of clinical points of interest    of the pulse wave allows obtaining parameters such as the index of vascular    rigidity and reflection that facilitate the evaluation of the vascular effects    of aging, hypertension and atherosclerosis. For this reason, the appropriate    localization of the onset, systolic peak, dicrotic notchs and the diastolic    peak of the arterial pulse wave is necessary. </font><font face="verdana" size="2"><strong>Objective:</strong>    To develop an algorithm for the localization of the onset, systolicpeak, dicrotic    notchs and the diastolic peak of the arterial pulse wave. </font><font face="verdana" size="2"><strong>Method:</strong>    The presented algorithm uses the first derivative linked to mobile conditionals    to eliminate unwanted points, as well as unreliable intervals. The algorithm    was evaluated using the annotation of an expert, with 5 records of arterial    pulse wave of 5 minutes (5236 annotations) and contaminated at different signal&#45;to&#45;noise    ratios (15, 12 and 9 dB). </font><font face="verdana" size="2"><strong>Results:</strong>    When compared with the annotations of an expert, the algorithm detected these    fiducial&nbsp; points with an average sensitivity, positive predictivity and    100% accuracy and showed errors of less than 10ms. In arterial pulse wave signals    contaminated with noise in both cases the relative error was less than 2% with    respect to a sampling period of 800ms. </font><font face="verdana" size="2"><strong>Conclusions:</strong>    the algorithm provides a simple but accurate detection of the clinicalpoints    of interest of the arterial pulse wave, robust to noise and movement artifacts    that could be used in the evaluation of the stiffness index and vascular reflection.</font></p>     <p class=keywords style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;indent:0cm'><font face="verdana" size="2"><strong>Key    words:</strong> arterial pulse wave, onset, systolic peak, dicrotic, diastolic    peak, detection algorithm.</font></p> <hr>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p align="center"><font face="Verdana" size="4"><b>INTRODUCCI&Oacute;N</b></font></p>     <p><font size="2" face="verdana">Las enfermedades cardiovasculares constituyen    una de las primeras causas de muerte en Cuba<sup>1</sup> &nbsp;y a nivel mundial.    El registro de la Onda de Pulso(OP) es una t&eacute;cnica de bajo costo y simple    que puede ser usada para medir los cambios en el volumen y/o presi&oacute;n    de la sangre en&nbsp; las arterias perif&eacute;ricas. De esta se&ntilde;al    se pueden obtener marcadores diagn&oacute;sticos relevantes tales como el tiempo    de tr&aacute;nsito de pulso y la velocidad de la onda de pulso.<sup>2</sup>    Estos par&aacute;metros brindan informaci&oacute;n de la propagaci&oacute;n    de la onda de pulso en el sistema vascular, ofreciendo as&iacute; indicadores    que son utilizados para evaluar la rigidez arterial, la frecuencia card&iacute;aca,&nbsp;    la respiraci&oacute;n, el ritmo card&iacute;aco, la presi&oacute;n sangu&iacute;nea    <sup>3</sup>.&nbsp; Este m&eacute;todo no invasivo sirve para el monitoreo de    diferentes enfermedades cardiovasculares que tienen como base la aterosclerosis    y la disfunci&oacute;n vascular, constituyendo la medici&oacute;n de la OP una    prueba aceptable para el p&uacute;blico en general por sus facilidades en el    proceso de&nbsp; medici&oacute;n y por no requerir gel conductor.&nbsp; </font><font face="verdana" size="2">Para    el c&aacute;lculo de estos marcadores es necesaria la localizaci&oacute;n de    puntos en el contorno de la onda de pulso en un ciclo card&iacute;aco. Los puntos    que m&aacute;s se utilizan son: el inicio de la onda de pulso (pie), el pico    sist&oacute;lico, la incisura dicrota y el pico diast&oacute;lico.<sup>4</sup>    <br>       <br>   El proceso utilizado para detectar estos puntos de la OP es complicado debido    a que &nbsp;estos factores generan varios tipos de artefactos aditivos que pueden    estar contenidos dentro de las se&ntilde;ales de OP. La morfolog&iacute;a de    la OP tambi&eacute;n est&aacute; influenciada por algunas condiciones fisiol&oacute;gicas    y procesos de enfermedad que en algunos casos pueden conducir a la insuficiente    claridad para la determinaci&oacute;n de los puntos de inter&eacute;s cl&iacute;nico    de la OP.     <br>       <br>   </font><font face="verdana" size="2">Existen diferentes m&eacute;todos para    la detecci&oacute;n del pie y el pico de la onda de pulso que incluyen umbrales    adaptativos, la extracci&oacute;n de caracter&iacute;sticas,<sup>5</sup> el    filtrado basado en ordenador,<sup>6</sup> la intersecci&oacute;n de una y dos    l&iacute;neas tangentes<sup>7</sup>&nbsp;c&aacute;lculo de derivadas, <sup>8</sup>    aprendizaje automatizado,<sup>9</sup> redes neuronales<sup>10</sup> y la transformada    de Hilbert. <sup>11 </sup>Resultan a su vez insuficientes los utilizados en    la de los otros puntos de la onda de pulso (incisura dicrota y pico diast&oacute;lico),<sup>8,9</sup>    no estando los mismos validados para una detecci&oacute;n&nbsp; robusta a ruidos    y artefactos de movimiento. En este contexto un algoritmo para la detecci&oacute;n    de puntos de inter&eacute;s de la onda de pulso es desarrollado. </font></p>     ]]></body>
<body><![CDATA[<p class=MsoNormal><font face="verdana" size="2">&nbsp;</font></p>    <p class=MsoNormal><font face="verdana" size="2">&nbsp;</font></p>     <p align="center" class=heading1 style='margin:0cm;margin&#45;bottom:.0001pt'><font face="verdana" size="3"><b>MATERIAL    Y M&Eacute;TODO</b></font></p>     <p align="center" class=heading1 style='margin:0cm;margin&#45;bottom:.0001pt'>&nbsp;</p>     <p class=MsoNormal><font face="verdana" size="2">A pesar de que el contorno de    la onda de pulso es menos complicado que otras se&ntilde;ales fisiol&oacute;gicas    como el ECG y EEC,&nbsp;&nbsp; no est&aacute; libre de ruidos de alta frecuencia    y baja frecuencia, derivados de la respiraci&oacute;n, del movimiento o del    equipo mismo de medici&oacute;n. El algoritmo propuesto (ver <a href="/img/revistas/rcim/v10n1/f0105118.jpg">figura    1</a>) utiliza la primera derivada unido a condicionales m&oacute;viles para    eliminar puntos no deseados, al igual que intervalos no confiables.</font></p>     <p class=MsoNormal>&nbsp;</p>     <p class=MsoNormal><font face="verdana" size="2"><strong>Condicionamiento de la    se&ntilde;al</strong></font></p>     <p class=MsoNormal><font face="verdana" size="2">Este paso consta de la implementaci&oacute;n    de un filtro digital para la cancelaci&oacute;n de los ruidos de alta frecuencia    y la eliminaci&oacute;n de la l&iacute;nea de base. El filtro digital es construido    usando un filtro pasa banda Butterworth de segundo orden con un ancho de banda    &#91;1 Hz&#45;15 Hz&#93;.</font></p> <font size="2" face="Verdana"><strong>    <br> A. Detecci&oacute;n de los puntos</strong></font>.      <p class=MsoNormal><font face="verdana" size="2">Se utiliz&oacute; la primera    derivada para encontrar los m&aacute;ximos y m&iacute;nimos locales de la se&ntilde;al.    La diferenciaci&oacute;n de la se&ntilde;al de onda de pulso filtrada es implementado    como</font></p>     ]]></body>
<body><![CDATA[<p class=MsoNormal><font face="verdana" size="2">d&#91;n&#93; = f&#91;n+ 1&#93; &#8722; f&#91;n&#93;&nbsp; (1)</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Despu&eacute;s    de la diferenciaci&oacute;n se normaliza la primera derivada por</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;    <img src="/img/revistas/rcim/v10n1/e0105118.jpg" width="141" height="55">(2)</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Los    puntos a identificar son cuatro: el pie, pico sist&oacute;lico, incisura dicrota    y elpico diast&oacute;lico. En un intervalo deben ser identificados estos cuatro    puntos. Por tanto la idea central del m&eacute;todo es utilizar condicionales    m&oacute;viles que se desplacen de un intervalo al otro identificando los puntos    arriba se&ntilde;alados. Desplaz&aacute;ndose en bloques de cuatro posibles    puntos por toda la se&ntilde;al eliminando cualquier punto que no cumpla con    las condiciones. </font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Estas    condiciones se describen a continuaci&oacute;n.</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Los    puntos a identificar deben cumplir con un orden de condiciones de amplitud:</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;<img src="/img/revistas/rcim/v10n1/e0205118.jpg" width="101" height="17">    (3)</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Donde    PS corresponde al pico sist&oacute;lico, PD al pico diast&oacute;lico, D a la    incisura dicr&oacute;tica y P al inicio de la onda de pulso (pie). De no ser    as&iacute; se elimina el primer punto. Esto ocurrir&aacute; de esta forma si    la se&ntilde;al no tiene picos espurios. Por tanto existe un paso crucial a    la hora de escoger el bloque de cuatro puntos a analizar. Si se determina un    intervalo de la onda de pulso por dos inicios consecutivos los m&aacute;ximos    y m&iacute;nimos locales determinan cuatro segmentos. Ahora bien, sabido esto,    se puede clasificar a los picos espurios a partir de su localizaci&oacute;n    en los segmentos mencionados. Pues para cada tipo de picos es purios existe    un procedimiento espec&iacute;fico. Por tanto existen picos espurio sen los    segmentos de tiempo P&#45;PS, PS&#45;D, D&#45;PD y PD&#45;P. Estos cuatro segmentos    se dividen en dos tipos los ascendentes (P&#45;PS, D&#45;PD) y los descendentes    (PS&#45;D,PD&#45;P), diferenci&aacute;ndose los segmentos dentro de un grupo    en la clasificaci&oacute;n de los extremos. Desde el inicio de la se&ntilde;al    de onda de pulso se comienza en el extremo del primer segmento y&nbsp; se asciende    buscando el otro extremo, este es el punto donde el pico que continua en la    se&ntilde;al es menor que &eacute;l, por tanto si se encuentra en este segmento    un pico donde el pico sucesor es mayor que &eacute;l, es eliminado junto con    su incisura correspondiente, de la misma forma para el otro segmento ascendente.</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Lo    contrario para los segmentos descendientes donde para eliminar un pico, el pico    sucesor tiene que ser menor que &eacute;l. Esto ligado al tiempo entre el primer    punto y los otros tres puntos y las amplitudes de dichos puntos, los cuales    se mueven en un intervalo adaptativo, garantiza una gran precisi&oacute;n a    la hora de eliminar puntos. </font></p> <strong><font size="2" face="Verdana">    <br> B. Datos de los pacientes</font></strong>      ]]></body>
<body><![CDATA[<p class=MsoNormal><font face="verdana" size="2">La base de datos est&aacute;    compuesta por se&ntilde;ales de cinco voluntarios, quienes participaron en el    protocolo experimental expresando su consentimiento informado de acuerdo con    la pol&iacute;tica institucional y de los principios de Helsinki. Cada sujeto    permaneci&oacute; en reposo durante cinco minutos en posici&oacute;n dec&uacute;bito    supino. La se&ntilde;al del sensor de tonometr&iacute;a del equipo Power lab    ® se digitaliz&oacute; a una frecuencia de muestreo de 1000 muestras/s, ancho    de banda de 0.5&#45;16 Hz en el paquete de software Lab Chart del 2012 ambos    de producci&oacute;n australiana&nbsp; por la compa&ntilde;&iacute;a AD Instruments.</font></p>     <br> <font size="2" face="Verdana"><strong>C. Validaci&oacute;n del m&eacute;todo&nbsp; </strong></font>      <p class=MsoNormal><font face="verdana" size="2">Los registros obtenidos durante    el protocolo experimental, para validar la robustezal ruido se us&oacute; la    metodolog&iacute;a propuesta por Kazanavicius y cols <sup>7</sup>.Cada se&ntilde;al    de la base de datos fue contaminada por diferentes relaciones se&ntilde;al ruido    blanco gaussiano (RSR) 15, 12 y 9 dB. Despu&eacute;s a cada realizaci&oacute;n    se le aplic&oacute; el m&eacute;todo para detectar los inicios, fue calculado    el error promedio y la desviaci&oacute;n est&aacute;ndar de la posici&oacute;n    de los puntos detectados de las se&ntilde;ales de OP contaminadas respecto a    las se&ntilde;ales sin contaminar. Para evaluar la exactitud y precisi&oacute;n    del algoritmo, los registros obtenidos durante el protocolo experimental fueron    anotados por un observador experto ciego al algoritmo. El experto anoto la localizaci&oacute;n    correcta del inicio de la onda de pulso, el pico sist&oacute;lico, la incisura    dicrota y el pico diast&oacute;lico usando un software dise&ntilde;ado para    visualizar y editar (agregar, mover y eliminar puntos fiduciales) se&ntilde;ales    de OP. Fueron hechas un total de 5236 anotaciones. La concordancia de las anotaciones    de los observadores, as&iacute; como&nbsp; la exactitud y precisi&oacute;n de    la nueva aplicaci&oacute;n se evaluaron mediante el an&aacute;lisis del&nbsp;    error&nbsp; absoluto, la desviaci&oacute;n est&aacute;ndar y el m&eacute;todo    de Bland&#45;Altman. En orden de calificar el rendimiento del algoritmo, fueron    determinadas la sensibilidad (SE), especificidad (E) predictibilidad&nbsp;positiva    (P+), taza de detecci&oacute;n de error (TDE ) usando las ecuaciones siguientes:</font></p>     <p class=MsoNormal><font face="verdana" size="2"><img src="/img/revistas/rcim/v10n1/e0405118.jpg" width="110" height="36">&nbsp;(4)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<img src="/img/revistas/rcim/v10n1/e0505118.jpg" width="122" height="35">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;(5)</font></p>     <p class=MsoNormal align=left style='text&#45;align:left;text&#45;indent:0cm;  mso&#45;element:frame;mso&#45;element&#45;frame&#45;hspace:2.25pt;mso&#45;element&#45;wrap:around;  mso&#45;element&#45;anchor&#45;vertical:paragraph;mso&#45;element&#45;anchor&#45;horizontal:column;  mso&#45;height&#45;rule:exactly'>&nbsp;</p>     <p class=MsoNormal align=left style='text&#45;align:left;text&#45;indent:0cm;  mso&#45;element:frame;mso&#45;element&#45;frame&#45;hspace:2.25pt;mso&#45;element&#45;wrap:around;  mso&#45;element&#45;anchor&#45;vertical:paragraph;mso&#45;element&#45;anchor&#45;horizontal:column;  mso&#45;height&#45;rule:exactly'>&nbsp;</p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;</font></p>     <p class=MsoNormal align=left style='text-align:left;text-indent:0cm'><font face="verdana" size="2">&nbsp;<img src="/img/revistas/rcim/v10n1/e0605118.jpg" width="167" height="20">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;(6)&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<img src="/img/revistas/rcim/v10n1/e0705118.jpg" width="200" height="25">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;(7)</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Donde(VP)    son los verdaderos positivos cuando: pie, picos sist&oacute;licos, incisurasdicr&oacute;ticas,    picos diast&oacute;licos son detectados por el algoritmo correctamente,(FN)    los falsos negativos cuando los puntos fiduciarios detectados son falsos y(FP)    los falsos positivos cuando picos de ruido son detectados como picos sist&oacute;licos    o diast&oacute;licos y artefactos de movimiento son detectados como algunos    de los puntos a detectar. Las ecuaciones (4)&#150;(7) son las mismas que las    ecuaciones&nbsp; (10)&#150;(13)&nbsp; de la Ref.<sup>12</sup> respectivamente.</font></p>     ]]></body>
<body><![CDATA[<p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;</font></p>    <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;</font></p>     <p class=MsoNormal align=center style='text&#45;align:center;text&#45;indent:0cm'><font face="verdana" size="3"><b>RESULTADOS    y DISCUSI&Oacute;N<br style='mso&#45;special&#45;character:line&#45;break'>   <br style='mso&#45;special&#45;character:line&#45;break'>   </b></font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">El    m&eacute;todo present&oacute; 0 falsos negativos, 0 falsos positivos y 0 raz&oacute;n    de detecci&oacute;n de error para un total de 5236 detecciones tanto de inicios    como de picos sist&oacute;licos. El m&eacute;todo muestra un promedio de exactitud    del 100%, sensibilidad del 100% y predictibilidad positiva del 100% en ambos    casos. Los resultados son similares a los obtenidos por Ricardo&#45;Ferro <sup>11</sup>.    La <a href="/img/revistas/rcim/v10n1/f0205118.jpg">Figura 2</a> muestra gr&aacute;ficos de Bland&#150;Altman    obtenidos, se muestran el an&aacute;lisis del grado de concordancia entre las    localizaciones del inicio, pico sist&oacute;lico, incisura dicr&oacute;tica    y pico diast&oacute;lico determinadas por&nbsp; el observador y el m&eacute;todo.    El observador entrenado selecciona como pie el comienzo de la onda incidente;    como pico sist&oacute;lico el pico de la onda incidente; como incisura dicr&oacute;tica    la muesca entre el primer pico (sist&oacute;lico) y el segundo pico (diast&oacute;lico);    como pico diast&oacute;lico el segundo pico luego de la incisura dicr&oacute;tica.    M&aacute;s del 99% de las detecciones de los puntos de la onda de pulso efectuadas    por el m&eacute;todo propuesto, tiene un error menor que 10 ms con respecto    al observador entrenado.</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'>&nbsp;</p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">Este    error promedio expuesto en la <a href="/img/revistas/rcim/v10n1/t0105118.gif">tabla 1</a>, oscila    entre 2.3213 a 3.0015 ms con leves variaciones entre cada tipo de detecci&oacute;n,&nbsp;    es similar al encontrado por varios autores con diferentes m&eacute;todos<sup>5&#45;10</sup>&nbsp;    en la b&uacute;squeda&nbsp;del pie y el pico sist&oacute;lico. Solo superado    en la precisi&oacute;n de la detecci&oacute;n la utilizaci&oacute;n de la Transformada    de Hilbert propuesto por Ricardo&#45;Ferro <sup>11</sup>,con un error promedio    con respecto a observadores de 0.08 y 0.23ms para el pie y el pico. Sin embargo    estos m&eacute;todos se caracterizan por una elevada complejidad metodol&oacute;gica    y computacional, as&iacute; como no est&aacute;n implementados, ni validados    para la detecci&oacute;n de la incisura dicr&oacute;tica y el pico diast&oacute;lico    como otros puntos de inter&eacute;s de la onda de pulso. En el algoritmo propuesto    todos los tipos de detecci&oacute;n del error medio son cercanos a cero, lo    cual demuestra la alta concordancia y sugiere que estas pueden ser usadas para    evaluar con exactitud y precisi&oacute;n los puntos de inter&eacute;s cl&iacute;nico    de la onda de pulso.</font></p>     <p class=MsoNormal><font face="verdana" size="2">&nbsp;</font></p>     <p class=MsoNormal><font face="verdana" size="2">La evaluaci&oacute;n de la robustez    al ruido se resume en la<a href="/img/revistas/rcim/v10n1/t0105118.gif"> tabla 1</a> y muestra    el rendimiento del m&eacute;todo para la detecci&oacute;n del pie, el pico sist&oacute;lico,    incisura dicr&oacute;tica y pico diast&oacute;lico en presencia de diferentes    niveles de ruido (RSR9,12 y 15 dB). Reportando errores que van desde 1.7517    ±1.6517 ms en la detecci&oacute;n del pie de la onda de pulso con ruidos 15dB    hasta11.6239± 9.9142 ms en la detecci&oacute;n del pico diast&oacute;lico con    ruido de 9 db en la se&ntilde;al. En todos los casos el m&eacute;todo puede    ser usado como indicador de la frecuencia cardiaca porque el error relativo    es menor que el 2% respecto a un periodo de muestreo de 800ms. Esto no difiere    de lo encontrado por algunos de los m&eacute;todos <sup>6,8,9,11</sup>.&nbsp;    en la detecci&oacute;n del pie y el pico, m&aacute;s exactos y robustos&nbsp;    a ruidos, llegando a tener errores m&aacute;ximos de 10.49 en algunas de sus    muestras <sup>11</sup>. El error en la detecci&oacute;n del pie y del pico sist&oacute;lico    para los tres niveles de ruido es menor que en la detecci&oacute;n de la incisura    dicr&oacute;tica y el pico de la onda de pulso; esto puede deberse a la presencia    de artefactos o ruido que impiden la correcta detecci&oacute;n de los puntos.</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">    <br>   Por otra parte se debe tener en cuenta que la incisura dicr&oacute;tica y el    pico diast&oacute;lico constituyen los puntos de la se&ntilde;al de onda de    pulso con mayor complejidad en su detecci&oacute;n, por sus grandes distorsiones    ante el ruido y por la gran variedad de tipos de ondas, estos componentes no    constituyen dianas fundamentales en el an&aacute;lisis e implementaci&oacute;n    por parte de la mayor&iacute;a de los m&eacute;todos reportados <sup>5, 6, 7,    10, 11</sup>. &nbsp;A su vez constituye la falta de&nbsp; validaci&oacute;n&nbsp;    contra artefactos de movimiento que se producen en los pacientes y alteran el    trazado de la se&ntilde;al, una de las limitantes de muchos de los m&eacute;todos    implementados <sup>8,9</sup> en la literatura revisada. El algoritmo propuesto    tiene un 100% de precisi&oacute;n en la exclusi&oacute;n de los artefactos de    movimiento por el an&aacute;lisis particularizado que se le realiza a los puntos    detectados, constituyendo una de las principales fortalezas del mismo que se    evidencia en la <a href="/img/revistas/rcim/v10n1/f0305118.jpg">figura 3</a>.</font></p>     ]]></body>
<body><![CDATA[<p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;El    m&eacute;todo propuesto tiene buena exactitud frente a ruido en todos los casos    debido la posibilidad de reducir las interferencias&nbsp; causadas por ruido    o distorsiones de la l&iacute;nea base con el propio dise&ntilde;o de las condicionales    m&oacute;viles para eliminar puntos no deseados, al igual que intervalos no    confiables.</font></p>     <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;</font></p>    <p class=MsoNormal style='text&#45;indent:0cm'><font face="verdana" size="2">&nbsp;</font></p>     <p class=MsoNormal align=center style='text&#45;align:center;text&#45;indent:0cm'><font face="verdana" size="2"><b><font size="3">CONCLUSIONES</font><br style='mso&#45;special&#45;character:line&#45;break'>   <br style='mso&#45;special&#45;character:line&#45;break'>   </b></font></p>     <p class=MsoPlainText><font face="verdana" size="2">Se presenta un algoritmo que    utiliza la primera derivada unido a condicionales m&oacute;viles para eliminar    puntos no deseados, para la detecci&oacute;n autom&aacute;tica del pie, pico    sist&oacute;lico, incisura dicr&oacute;tica y del pico diast&oacute;lico en    se&ntilde;ales de onda de pulso, con&nbsp; baja complejidad metodol&oacute;gica    y muy bajo costo computacional. Este m&eacute;todo tambi&eacute;n muestra baja    tasa de error para la detecci&oacute;n estos puntos fiduciales para diferentes    niveles de ruido, demostrando que tiene una buena exactitud frente a ruido y    artefactos de movimiento. El m&eacute;todo logra un promedio &oacute;ptimo de    sensibilidad, predictibilidad positiva y la precisi&oacute;n m&aacute;xima en    todas las detecciones.</font></p>     <p class=MsoPlainText>&nbsp;</p>     <p class=MsoPlainText>&nbsp;</p>     <p class=MsoPlainText><font face="verdana" size="3"><b>REFERENCIAS BIBLIOGR&Aacute;FICAS    <br style='mso&#45;special&#45;character:line&#45;break'>   </b></font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">1.    Direcci&oacute;n de Registros M&eacute;dicos y Estad&iacute;sticas de Salud    del Ministerio de Salud P&uacute;blica de Cuba. (2016) Anuario Estad&iacute;stico    de Salud. 2015. La Habana.    </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">2.    Allen J, Murray A. Age&#45;related changes in peripheral pulse timing characteristics    at the ears, fingers and toes. J.&nbsp; Hum. Hypertens. 2002; 16: 711&#150;717.    </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">3.    Allen J. Photoplethys mography and its application in clinical physiological    measurement, Physiol. Meas.Top. Rev. 2007; 28: 1&#150;39.    </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">4.    Pascau A,Fernandez JE, Allen J. Nuevos modelos conceptual y matem&aacute;tico    para el contorno de la onda de volumen de pulso arterial. Revista&nbsp; Cubana    de Investigaciones Biom&eacute;dicas 2011; 30 (4): 487&#45;500.    &nbsp; </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">5.    Xu P,Bergsneider M, Hu X. &nbsp;Pulse onset detection using neighbor pulse&#45;based    signal enhancement. Med. Eng. Phys 2009;&nbsp; 31: 337&#150;345.     </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">6.    Jang DG, Park S, Hahn M. A real&#45;time pulse peak detection method for the    photoplethysmogram. Int. J. Electron. Electr. Eng 2014; 2:(1).     </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">7.    Kazanavicius E, Gircys R, Vrubliauskas A, Lugin S. Mathematical methods for    determining the onset point of the arterial pulse wave and evaluation of proposed    methods. Inform.Technol. Control 2005; 34 (1): 29&#150;36.    </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">8.    Elgendi M. On the analysis of fingertip photoplethysmogram signals. Current    Cardiology Reviews 2012; 8: 14&#45;25.    </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">9.    Grabovskis A, Marcinkevics Z, Rubenis O, Rubins U, Lusa V. Photoplethysmography    system for blood pulsation detection in unloaded artery conditions. Proc. of    SPIE Vol. 8427 84270L&#45;1 .En l&iacute;nea: doi: 10.1117/12.922649 Consultado:    14 jun 2016.     </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">10.&nbsp;Orjuela    AD, Delisle D, &nbsp;L&oacute;pez A,&nbsp;Fernandez&nbsp; RR, &nbsp;Cuadra MB.    Onset and peak pattern recognition on photoplethys mographic signals using neural    networks.&nbsp; Ruiz&#45;Shulcloper E, &nbsp;Sanniti di Baja G. Editores. Progress    In Pattern Recognition, Image Analysis, Computer Vision, and Applications. Volume    8258 ed. Berlin: Springer&#45;Verlag; 2013. p. 543&#150;550.    </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">11.&nbsp;Ricardo    BT, Ram&iacute;rez A, Fern&aacute;ndez RR. Automated detection of the onset    and systolic peak in the pulse wave using Hilbert Transform Biomedical Signal    Processing and Control 2015; 20: 78&#150;84.     </font></p>     <!-- ref --><p class=MsoListParagraph style='margin&#45;left:14.2pt;text&#45;indent:&#45;7.1pt'><font face="verdana" size="2">12.&nbsp;Sabarimalai    M, Soman K.P. A novel method for detectingR&#45;peaks in electrocardiogram (ECG)    signal. &nbsp;Biomedical Signal Processing and Control 2011; 7 (2):118&#150;128.    </font></p>     <p class=MsoNormal><font face="verdana" size="2">&nbsp;</font></p>    <p class=MsoNormal><font face="verdana" size="2">&nbsp;</font></p>    <p class=MsoNormal><font face="verdana" size="2">&nbsp;</font></p>    <p class=MsoNormal><font face="verdana" size="2">&nbsp;</font></p>    <p style='margin:0cm;margin&#45;bottom:.0001pt'><font face="verdana" size="2">Recibido: 20 de enero de 2018.     <br>Aprobado: 15 de marzo de 2018.</font></p>     ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<collab>Ministerio de Salud Pública de Cuba^dDirección de Registros Médicos y Estadísticas de Salud</collab>
<source><![CDATA[Anuario Estadístico de Salud]]></source>
<year>2016</year>
<publisher-loc><![CDATA[La Habana ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Allen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Murray]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Age-related changes in peripheral pulse timing characteristics at the ears, fingers and toes]]></article-title>
<source><![CDATA[J. Hum. Hypertens]]></source>
<year>2002</year>
<volume>16</volume>
<page-range>711-717</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Allen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Photoplethys mography and its application in clinical physiological measurement]]></article-title>
<source><![CDATA[Physiol. Meas.Top. Rev]]></source>
<year>2007</year>
<volume>28</volume>
<page-range>1-39</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pascau]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fernandez]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Allen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Nuevos modelos conceptual y matemático para el contorno de la onda de volumen de pulso arterial]]></article-title>
<source><![CDATA[Revista Cubana de Investigaciones Biomédicas]]></source>
<year>2011</year>
<volume>30</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>487-500</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bergsneider]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hu]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pulse onset detection using neighbor pulse-based signal enhancement]]></article-title>
<source><![CDATA[Med. Eng. Phys]]></source>
<year>2009</year>
<volume>31</volume>
<page-range>337-345</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jang]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Hahn]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A real-time pulse peak detection method for the photoplethysmogram]]></article-title>
<source><![CDATA[Int. J. Electron. Electr. Eng]]></source>
<year>2014</year>
<volume>2</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kazanavicius]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Gircys]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Vrubliauskas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Lugin]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mathematical methods for determining the onset point of the arterial pulse wave and evaluation of proposed methods]]></article-title>
<source><![CDATA[Inform.Technol. Control]]></source>
<year>2005</year>
<volume>34</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>29-36</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Elgendi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On the analysis of fingertip photoplethysmogram signals]]></article-title>
<source><![CDATA[Current Cardiology Reviews]]></source>
<year>2012</year>
<volume>8</volume>
<page-range>14-25</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grabovskis]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Marcinkevics]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Rubenis]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Rubins]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Lusa]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Photoplethysmography system for blood pulsation detection in unloaded artery conditions]]></article-title>
<source><![CDATA[Proc. of SPIE]]></source>
<year></year>
<volume>8427 84270L-1</volume>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Orjuela]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
<name>
<surname><![CDATA[Delisle]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fernandez]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
<name>
<surname><![CDATA[Cuadra]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Onset and peak pattern recognition on photoplethys mographic signals using neural networks]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Ruiz-Shulcloper]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Sanniti di Baja]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[Pattern Recognition, Image Analysis, Computer Vision, and Applications]]></source>
<year>2013</year>
<volume>8258</volume>
<page-range>543-550</page-range><publisher-loc><![CDATA[Berlin ]]></publisher-loc>
<publisher-name><![CDATA[Springer-Verlag]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ricardo]]></surname>
<given-names><![CDATA[BT]]></given-names>
</name>
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fernández]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
</person-group>
<source><![CDATA[Automated detection of the onset and systolic peak in the pulse wave using Hilbert Transform Biomedical Signal Processing and Control]]></source>
<year>2015</year>
<volume>20</volume>
<page-range>78-84</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sabarimalai]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Soman]]></surname>
<given-names><![CDATA[K.P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A novel method for detectingR-peaks in electrocardiogram (ECG) signal]]></article-title>
<source><![CDATA[Biomedical Signal Processing and Control]]></source>
<year>2011</year>
<volume>7</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>118-128</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>