<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1815-5901</journal-id>
<journal-title><![CDATA[Ingeniería Energética]]></journal-title>
<abbrev-journal-title><![CDATA[Energética]]></abbrev-journal-title>
<issn>1815-5901</issn>
<publisher>
<publisher-name><![CDATA[Universidad Tecnológica de La Habana José Antonio Echeverría, Cujae]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1815-59012018000300005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Análisis del campo magnético en una institución hospitalaria]]></article-title>
<article-title xml:lang="en"><![CDATA[Analysis of the magnetic field in a hospital institution]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Carvajal de la Osa]]></surname>
<given-names><![CDATA[Janet]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez Almirall]]></surname>
<given-names><![CDATA[Ignat]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Castro Fernandez]]></surname>
<given-names><![CDATA[Miguel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Tecnológica de la Habana  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2018</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2018</year>
</pub-date>
<volume>39</volume>
<numero>3</numero>
<fpage>176</fpage>
<lpage>185</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1815-59012018000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1815-59012018000300005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1815-59012018000300005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Los daños ocasionados por el exceso de la radiación de campos electromagnéticos se han convertido en un problema de salud mundial, siendo los niños unos de los mas propensos a contraer enfermedades por esta causa. En este trabajo se comprobó el ambiente electromagnético de cuatro cubículos de internamiento de la sala de terapia intensiva del hospital pediatrico ¨William Soler¨. Se utilizó para este propósito un gaussímetro modelo Emdex II para realizar las mediciones, herramientas informáticas para procesar los datos obtenidos en ellas y las recomendaciones del 2010 emitidas por la Comision Internacional Para La Protección Contra Las Radiaciones No Ionizantes ( por sus siglas en inglés ICNIRP) como patrón para hacer comparaciones, las mediciones se realizaron según protocolos descritos en literaturas científicas y acorde con lo recomendado por la normas epidemiológicas del Ministerio de Salud Pública (MINSAP) cubano. Los valores medidos no sobrepasaron a los recomendados por la ICNIRP]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The damage caused by excess to electromagnetic fields radiations are the global health problem being the children the most, afected by this reason. In this work was checked the electromagnetic enviroment of 4 internment cubicle of “William Soler “ Hospital intensitive terapy room, for it purpose was used Emdex II gaussimeter in order to make measurements,computer tools to process the data obtained in them and the recommendation emited by international commission for the protection against non-ionizing radiation (ICNIRP) in 2010 as a standard for comparisons, the measurementwere maked according to the established by protocol in cientific literature, according to hepidemiology standard of cuban health Ministry. The result of the measurement obtained were lower than recommended by ICNIRP, so the result are positive]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Campos electromagnéticos]]></kwd>
<kwd lng="es"><![CDATA[daños a la salud humana]]></kwd>
<kwd lng="es"><![CDATA[institución hospitalaria]]></kwd>
<kwd lng="en"><![CDATA[electromagnetic fields]]></kwd>
<kwd lng="en"><![CDATA[human healt damage]]></kwd>
<kwd lng="en"><![CDATA[hospital institution]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font face="verdana" size="2"><b>TRABAJO TE&Oacute;RICO EXPERIMENTAL</b></font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="4"><b>An&aacute;lisis del campo magn&eacute;tico en una instituci&oacute;n hospitalaria </b></font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="3"><b>Analysis of the magnetic field in a hospital institution</b></font></p>     <p align="justify">&nbsp;</p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="2"><b>Janet Carvajal de la Osa, Ignat P&eacute;rez Almirall, Miguel Castro Fernandez</b></font></p>     <p align="justify"><font face="verdana" size="2">Universidad Tecnológica de la Habana, Cujae, Cuba.</font></p>     <p align="justify">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2"><br />   <br />    </font></p> <hr />     <p align="justify"><font face="verdana" size="2"><b>RESUMEN</b></font></p>     <p align="justify"><font face="verdana" size="2">Los da&ntilde;os ocasionados por el exceso de la radiaci&oacute;n de campos electromagn&eacute;ticos se han convertido en un problema de salud mundial, siendo los ni&ntilde;os unos de los mas propensos a contraer enfermedades por esta causa. En este trabajo se comprob&oacute; el ambiente electromagn&eacute;tico de cuatro cub&iacute;culos de internamiento de la sala de terapia intensiva del hospital pediatrico &uml;William Soler&uml;. Se utiliz&oacute; para este prop&oacute;sito un gauss&iacute;metro modelo Emdex II para realizar las mediciones, herramientas inform&aacute;ticas para procesar los datos obtenidos en ellas y las recomendaciones del 2010 emitidas por la Comision Internacional Para La Protecci&oacute;n Contra Las Radiaciones No Ionizantes ( por sus siglas en ingl&eacute;s ICNIRP) como patr&oacute;n para hacer comparaciones, las mediciones se realizaron seg&uacute;n protocolos descritos en literaturas cient&iacute;ficas y acorde con lo recomendado por la normas epidemiol&oacute;gicas del Ministerio de Salud P&uacute;blica (MINSAP) cubano. Los valores medidos no sobrepasaron a los recomendados por la ICNIRP.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Palabras clave: </b>Campos electromagn&eacute;ticos;da&ntilde;os a la salud humana; instituci&oacute;n hospitalaria.</font></p> <hr />     <p align="justify"><font face="verdana" size="2"><b>ABSTRACT</b></font></p>     <p align="justify"><font face="verdana" size="2">The damage caused by excess to electromagnetic fields radiations are the global health problem being the children the most, afected by this reason. In this work was checked the electromagnetic enviroment of 4 internment cubicle of &ldquo;William Soler &ldquo; Hospital intensitive terapy room, for it purpose was used Emdex II gaussimeter in order to make measurements,computer tools to process the data obtained in them and the recommendation emited by international commission for the protection against non-ionizing radiation (ICNIRP) in 2010 as a standard for comparisons, the measurementwere maked according to the established by protocol in cientific literature, according to hepidemiology standard of cuban health Ministry. The result of the measurement obtained were lower than recommended by ICNIRP, so the result are positive.</font></p>     <p align="justify"><font face="verdana" size="2"><b> Key words:</b> &nbsp;electromagnetic fields; human healt damage; hospital institution.</font></p> <hr />     <p align="justify">&nbsp;</p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="3"><b>INTRODUCCI&Oacute;N</b></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Los da&ntilde;os causados por los campos electromagn&eacute;ticos han sido declarados por la Organizaci&oacute;n Mundial de la Salud (OMS), como un problema de salud mundial. Siendo los ni&ntilde;os y los trabajadores del sector el&eacute;ctrico los m&aacute;s estudiados por los cient&iacute;ficos de todo el mundo.</font></p>     <p align="justify"><font face="verdana" size="2">Las primeras sospechas acerca de esto se obtuvieron en la antigua Uni&oacute;n Sovi&eacute;tica por un grupo de cient&iacute;ficos dirigidos por Korobkova&#93;, los que observaron extra&ntilde;as alteraciones entre la salud de los trabajadores de las empresas donde la exposici&oacute;n a campos electromagn&eacute;ticos era prolongada y constante. Estas observaciones no se hicieron evidentes hasta que los doctores Wertheimer y Ed Leeper &#91;2&#93; realizaron estudios a ni&ntilde;os, los que fueron secundados por otros grupos de cient&iacute;ficos a lo largo de las dos d&eacute;cadas siguientes, entre los que se encontraron David Savitz&#91;3&#93;, S.Jlondon&#91;4&#93;, Mar&iacute;a Feychting y Anders Ahlbom&#91;5&#93;, entre otros.</font></p>     <p align="justify"><font face="verdana" size="2">Estos estudios realizados en los finales del pasado siglo, tanto en Europa como Am&eacute;rica, expon&iacute;an que los campos electromagn&eacute;ticos de baja frecuencia pod&iacute;an actuar sobre las c&eacute;lulas, mediante mecanismos que provocaban, a determinados frecuencias y a largo plazo, afecciones tanto a nivel celular, hormonal, como gen&eacute;tico, pues afectaban la composici&oacute;n de las sustancias que formaban las prote&iacute;nas del ADN&#91;6;7&#93;.</font></p>     <p align="justify"><font face="verdana" size="2">Recientemente se han desarrollado investigaciones a nivel mundial, que corroboran las realizadas anteriormente y se realizan nuevos hallazgos, como por ejemplo, en las investigaciones dirigidas por Martin L. Pall, Neil Cherry&#91;8&#93;, Olle Johansson&#91;9&#93;, J.F. Bolten&#91;10&#93;, Karipidis&#91;11&#93;, Solano y Saiz&#91;12&#93;, entre otros.</font></p>     <p align="justify"><font face="verdana" size="2">Debido a estos hallazgos, la OMS, que en 1998 decidi&oacute; realizar recomendaciones acerca de los l&iacute;mites de este tipo de radiaci&oacute;n y que le encomend&oacute; la tarea a la ICNIRP, decidi&oacute; en 2010 actualizar las mismas, revisarlas y corregir estos l&iacute;mites&#91;13&#93;. Recomendaciones estas, que est&aacute;n siendo utilizadas por pa&iacute;ses de todo el mundo como gu&iacute;a para confeccionar sus normativas.</font></p>     <p align="justify"><font face="verdana" size="2">En Cuba desde los a&ntilde;os 80 y hasta la fecha, cient&iacute;ficos como Barcel&oacute; P&eacute;rez &#91;14&#93; y Suarez Cabrera&#91;15&#93;, investigaron lugares de trabajo y efectos sobre los trabajadores y la poblaci&oacute;n, uni&eacute;ndoseles otros grupos investigativos de diferentes regiones y sectores, dirigidos por Hidalgo de la Paz&#91;16&#93;, P&eacute;rez Alejo&#91;17&#93;, Castro Fern&aacute;ndez&#91;18;19&#93;, Revueltas Ag&uuml;ero &#91;20&#93; y D&eacute;as Yero&#91;21;22&#93;, entre otros. Aunque a pesar de ello, no se tiene conocimiento de una normativa o regulaci&oacute;n vigente sobre este tema en nuestro pa&iacute;s.</font></p>     <p align="justify"><font face="verdana" size="2">Debido a que se ha comprobado el da&ntilde;o que ocasionan la exposici&oacute;n prolongada a este tipo de radiaci&oacute;n y a la ausencia de una normativa acerca de este tema en nuestro pa&iacute;s, es necesario comprobar si las instituciones hospitalarias responden a esos l&iacute;mites recomendados por la ICNIRP; para as&iacute; trazar estrategias de protecci&oacute;n a las personas que deambulan, trabajan o son atendidos en las mismas.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="3"><b>MATERIALES Y METODO</b></font></p>     <p align="justify"><font face="verdana" size="2">Para la realizaci&oacute;n del trabajo, se utilizar&aacute; un gauss&iacute;metro de la marca EMDEX II, para realizar la medici&oacute;n del campo magn&eacute;tico, cuyas caracter&iacute;sticas se muestran en la <a href="#t1">tabla1</a> y en la <a href="#f1">figura 1</a>.</font></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="t1" id="t1"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/t0105318.gif" alt="Tabla1. Caracteristicas del gauss&iacute;metro EMDEX II." width="543" height="291" longdesc="/img/revistas/rie/v39n3/t0105318.gif" /></p>     
<p align="center"><a name="f1" id="f1"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0105318.gif" alt="Fig.1. Gaussimetro EMDEX II, utilizado para realizar las mediciones." width="457" height="184" longdesc="/img/revistas/rie/v39n3/f0105318.gif" /></p>     
<p align="justify"><font face="verdana" size="2">Tambi&eacute;n se utilizar&aacute;n herramientas inform&aacute;ticas para realizar el procesamiento de los datos como son el programa Matlab R2010b (Versi&oacute;n 7.11) para realizar el mapeo de los valores obtenidos en la medici&oacute;n, el programa Visio 2010 para realizar los croquis de los locales, el programa Excel que posee el paquete del Office 2010 para realizar las gr&aacute;ficas de comparaci&oacute;n, y el programa Statgraphics plus versi&oacute;n 5 para procesar estad&iacute;sticamente los datos obtenidos y validar los resultados. Tambi&eacute;n se utilizar&aacute; la recomendaci&oacute;n de la ICNIRP emitida en el a&ntilde;o 2010&#91;13&#93;, como herramienta para comparar los valores obtenidos en la medici&oacute;n con los que en ella se recomiendan; pues la misma ha sido la que m&aacute;s recientemente ha revisado sus l&iacute;mites de exposici&oacute;n y adem&aacute;s la que trabaja en conjunto con la OMS para tratar los problemas de las radiaciones no ionizantes y la salud.</font></p>     <p align="justify"><font face="verdana" size="2"><b>Metodolog&iacute;a de la investigaci&oacute;n</b></font></p> <ul type="disc">     <li>    <p align="justify"><font face="verdana" size="2">Como primer paso de la investigaci&oacute;n se debe caracterizar el hospital y las &aacute;reas donde se realizar&aacute; la medici&oacute;n con respecto a la infraestructura f&iacute;sica e infraestructura tecnol&oacute;gica.</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">Como segundo paso se obtendr&aacute;n los croquis de cada &aacute;rea, para ubicar los puntos necesarios para la realizaci&oacute;n de las mediciones y mapear los valores obtenidos a trav&eacute;s de colores. Este mapeo se utilizar&aacute; para obtener los puntos de donde procede la contaminaci&oacute;n en el &aacute;rea.</font></p></li>     ]]></body>
<body><![CDATA[<li>    <p align="justify"><font face="verdana" size="2">Luego se establecer&aacute;n las condiciones de los locales a fin de conocer cu&aacute;les son nuestras variables a controlar y cuales a medir.</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">Seguidamente se realizar&aacute;n las mediciones en cada una de las &aacute;reas escogidas de la siguiente manera:</font></p></li>     </ul> <font face="verdana" size="2"><ol>     <li>    <p align="justify"><font face="verdana" size="2">Definir zonas de inter&eacute;s para las mediciones.</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">Realizar una malla rectangular metro a metro de dimensi&oacute;n n x m equivalente a una matriz como se muestra en la <a href="#f2">figura 2</a> e ir desplazando el equipo de medici&oacute;n sobre cada punto de la malla para realizar un promedio espacial, midiendo en modo discreto (punto a punto), para posteriormente realizar un promedio de los valores obtenidos.</font></p></li>     <li>    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Las mediciones de campo magn&eacute;tico se comenzar&aacute;n a realizar por la esquina contraria y m&aacute;s alejada de la puerta de entrada, a favor de las manecillas del reloj y en forma de zigzag como se puede apreciar en la <a href="#f2">figura 2</a>. Se coloca el gauss&iacute;metro a un metro de distancia sobre el nivel del suelo y con un metro de distancia entre cada punto de medici&oacute;n. Los valores de la medici&oacute;n se tomar&aacute;n a esta altura por ser a la que generalmente se encuentran situados la mayor cantidad de &oacute;rganos en el cuerpo de las personas de estatura promedio. Adem&aacute;s, por ser la altura que toma la ICNIRP en su protocolo para realizar las pruebas que dan los l&iacute;mites de sus recomendaciones&#91;23;24&#93;.</font></p></li>     </ol> </font><font face="verdana" size="2"><ul>       <li>    <p align="justify"><font face="verdana" size="2">La medici&oacute;n se repetir&aacute; cinco veces y los valores se plasmar&aacute;n en tablas que luego se procesar&aacute;n a trav&eacute;s de an&aacute;lisis estad&iacute;stico, con el fin de dar veracidad a los valores de contaminaci&oacute;n electromagn&eacute;tica determinado en las condiciones establecidas</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">Como quinto paso se comparar&aacute;n los promedios obtenidos a trav&eacute;s del procesamiento de los datos con las recomendaciones de la ICNIRP 2010, para conocer el estado de la contaminaci&oacute;n del &aacute;rea y si los niveles sobrepasan los recomendados. Los resultados de la comparaci&oacute;n se mostrar&aacute;n a trav&eacute;s de una gr&aacute;fica.</font></p></li>     </ul> </font>     <p align="center"><a name="f2" id="f2"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0205318.gif" alt="Fig. 2. Ejemplo del recorrido utilizado para realizar la medici&oacute;n." width="543" height="160" longdesc="/img/revistas/rie/v39n3/f0205318.gif" /></p>     
<p align="justify">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="3"><b>RESULTADOS Y DISCUSI&Oacute;N</b></font><font face="verdana" size="2"></font></p> <font face="verdana" size="2"><ol start="1" type="1">     <li>    <p align="justify"><font face="verdana" size="2">Se obtuvieron las caracter&iacute;sticas de estructura y tecnol&oacute;gica de las salas de terapia y el r&eacute;gimen de trabajo del equipamiento a que estaban sometidas las mismas al momento de la medici&oacute;n, como se muestra en la <a href="#t2">tabla 2</a>:</font></p></li>     </ol> </font>     <p align="center"><a name="t2" id="t2"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/t0205318.gif" alt="Tabla 2. Caracter&iacute;sticas de estructura y tecnol&oacute;gicaa de las salas de terapia" width="580" height="445" longdesc="/img/revistas/rie/v39n3/t0205318.gif" /></p>     
<p align="justify"><font face="verdana" size="2">En la <a href="#t2">tabla 2</a>, se muestran las salas 1 y 4 con caracter&iacute;sticas de trabajo diferentes a las 2 y 3. Esto es debido a que no exist&iacute;an pacientes internados al momento de la medici&oacute;n.</font></p>     <p align="justify"><font face="verdana" size="2">Se obtuvo el plano de la planta o croquis con el que se realiz&oacute; la malla de medici&oacute;n, la zona coloreada en rojo es el &aacute;rea de inter&eacute;s, como se muestra en la <a href="#f3">figura 3</a>.</font><font face="verdana" size="2"></font></p>     <p align="center"><a name="f3" id="f3"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0305318.gif" alt="Fig. 3. Plano de la planta obtenido por los autores partiendo del programaVisio." width="543" height="229" longdesc="/img/revistas/rie/v39n3/f0305318.gif" /></p> <font face="verdana" size="2"><ol start="2" type="1">     
]]></body>
<body><![CDATA[<li>    <p align="justify"><font face="verdana" size="2">A partir del plano anterior se traz&oacute; el recorrido a seguir en cada sala, como est&aacute; descrito en la metodolog&iacute;a para realizar las mediciones y que se muestra a continuaci&oacute;n en la <a href="#f4">figura 4</a>.</font></p></li>     </ol> <ol start="3" type="1">     <li>    <p align="justify"><font face="verdana" size="2">Teniendo definidos los aspectos anteriores se procede a realizar las mediciones. Con los valores obtenidos en cada punto medido durante los cinco d&iacute;as en que se realizaron las mediciones, se calcul&oacute; el promedio en cada sala.</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">Con los promedios de cada punto calculados, se confeccion&oacute; un mapa de colores que se muestra en las <a href="#f5">figuras 5</a>, <a href="#f6">6</a>, <a href="#f7">7</a>, <a href="#f8">8</a>. Los colores rojos nos indican los puntos con los valores m&aacute;s altos de radiaci&oacute;n medidos.</font></p></li>     </ol> </font>     <p align="center"><a name="f4" id="f4"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0405318.gif" alt="Fig. 4. Recorrido seguido para realizar las mediciones." width="543" height="165" longdesc="/img/revistas/rie/v39n3/f0405318.gif" /></p>     
]]></body>
<body><![CDATA[<p align="center"><a name="f5" id="f5"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0505318.gif" alt="Fig.5. Representaci&oacute;n de los valores promedios, a trav&eacute;s de un mapa de colores, obtenidos en T en las mediciones en la sala1 durante cinco d&iacute;as de medici&oacute;n" width="543" height="194" longdesc="/img/revistas/rie/v39n3/f0505318.gif" /></p>     
<p align="center"><a name="f6" id="f6"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0605318.gif" alt="Fig. 6. Representaci&oacute;n de los valores promedios obtenidos en T en las mediciones en la sala 2 durante cinco d&iacute;as de medici&oacute;n." width="543" height="189" longdesc="/img/revistas/rie/v39n3/f0605318.gif" /></p>     
<p align="center"><a name="f7" id="f7"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0705318.gif" alt="Fig.7. Representaci&oacute;n de los valores promedios obtenidos en T en las mediciones en la sala 3 durante cinco d&iacute;as de medici&oacute;n." width="543" height="176" longdesc="/img/revistas/rie/v39n3/f0705318.gif" /></p>     
<p align="center"><a name="f8" id="f8"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0805318.gif" alt="Fig.8. Representaci&oacute;n de los valores promedios obtenidos en T en las mediciones en la sala 4 durante cinco d&iacute;as de medici&oacute;n." width="543" height="190" longdesc="/img/revistas/rie/v39n3/f0805318.gif" /></p>     
<p align="justify"><font face="verdana" size="2">Con los valores obtenidos se realiz&oacute; un an&aacute;lisis estad&iacute;stico por muestreo aleatorio simple, teniendo en cuenta que existe un rango de &plusmn;2.0&times;10<sup>-7</sup> Tesla (T) donde deben estar ubicados los valores de las estad&iacute;sticas obtenidas para que se comporte acorde a una distribuci&oacute;n normal. Si los valores obtenidos a trav&eacute;s del an&aacute;lisis no concuerdan dentro de este rango entonces se anulan los resultados.</font></p> <ul type="disc">     <li>    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Para la sala 1 los resultados se muestran en la <a href="#t3">tabla 3</a> :</font></p>       <p align="center"><a name="t3" id="t3"></a></p>       <p align="center"><img src="/img/revistas/rie/v39n3/t0305318.gif" alt="Tabla 3. Resultados obtenidos en el an&aacute;lisis estad&iacute;stico para la sala 1" width="459" height="192" longdesc="/img/revistas/rie/v39n3/t0305318.gif" /></p> </li>     
</ul> <font face="verdana" size="2"><ul>       <li>    <p align="justify"><font face="verdana" size="2">Para la sala 2 los resultados se muestran en la <a href="#t4">tabla 4</a>:</font></p>         <p align="center"><a name="t4" id="t4"></a></p>         <p align="center"><img src="/img/revistas/rie/v39n3/t0405318.gif" alt="Tabla 4. Resultados obtenidos en el an&aacute;lisis estad&iacute;stico para la sala 2." width="469" height="197" longdesc="/img/revistas/rie/v39n3/t0405318.gif" /></p>   </li>     
</ul> </font><font face="verdana" size="2"><ul>     <li>    ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Para la sala 3. los resultados se muestran en la <a href="#t5">tabla 5</a>:</font></p>       <p align="center"><a name="t5" id="t5"></a></p>       <p align="center"><img src="/img/revistas/rie/v39n3/t0505318.gif" alt="Tabla 5. Resultados obtenidos en el an&aacute;lisis estad&iacute;stico para la sala 3." width="469" height="197" longdesc="/img/revistas/rie/v39n3/t0505318.gif" /></p> </li>     
</ul> </font><font face="verdana" size="2"><ul>     <li>    <p align="justify"><font face="verdana" size="2">Para la sala 4 los resultados se muestran en la <a href="#t6">tabla 6</a>:</font></p>       <p align="center"><a name="t6" id="t6"></a></p>       <p align="center"><img src="/img/revistas/rie/v39n3/t0605318.gif" alt="Tabla 6. Resultados obtenidos en el an&aacute;lisis estad&iacute;stico para la sala 4." width="469" height="197" longdesc="/img/revistas/rie/v39n3/t0605318.gif" /></p> </li>     
</ul> </font>     <p align="justify"><font face="verdana" size="2">El an&aacute;lisis de los datos permiti&oacute; validar que los valores promedios de campo magn&eacute;tico obtenidos, son valores confiables para un 95% de las veces que se repitan las mediciones en esta muestra, si los mismos se encuentren entre:</font></p><font face="verdana" size="2"><ul>     ]]></body>
<body><![CDATA[<li>    <p align="justify"><font face="verdana" size="2">En la sala 1 entre 1,68&times;10<sup>-7</sup> T y 2,9&times;10<sup>-7</sup> T y la desviaci&oacute;n est&aacute;ndar entre los valores 3,75&times;10<sup>-7</sup> T y 4,61&times;10<sup>-7</sup> T.</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">En la sala 2 entre 6,20&times;10<sup>-8</sup> T y 7,4&times;10<sup>-8</sup> T y la desviaci&oacute;n est&aacute;ndar entre los valores 3,8&times;10<sup>-8</sup> T y 4,7&times;10<sup>-8</sup> T.</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">En la sala 3 entre 4,4&times;10<sup>-8</sup> T y 5,7&times;10<sup>-8</sup> T y su desviaci&oacute;n est&aacute;ndar entre los valores 4,2&times;10<sup>-8</sup> T y 5,1&times;10<sup>-8</sup> T.</font></p></li>     <li>    <p align="justify"><font face="verdana" size="2">En la sala 4 entre 1,7&times;10<sup>-7</sup> T y 2,64&times;10<sup>-7</sup> T, y la desviaci&oacute;n est&aacute;ndar entre 2,88&times;10<sup>-7</sup> T y 3,55&times;10<sup>-7</sup> T.</font></p></li>     </ul> </font>     <p align="justify"><font face="verdana" size="2">Tomando los valores promedios obtenidos a trav&eacute;s de nuestro an&aacute;lisis y compar&aacute;ndolos con las recomendaciones de la ICNIRP cuyos valores son, 2&times;10<sup>-4 </sup>T para el l&iacute;mite ocupacional y 1&times;10<sup>-3 </sup>T para la poblaci&oacute;n en general obtenemos la gr&aacute;fica que exponemos en la <a href="#f9">figura 9</a>.</font></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="f9" id="f9"></a></p>     <p align="center"><img src="/img/revistas/rie/v39n3/f0905318.gif" alt="Fig. 9. Gr&aacute;fica que muestra los valores obtenidos mediante la medici&oacute;n y los l&iacute;mites recomendados por la ICNIRP 2010." width="543" height="287" longdesc="/img/revistas/rie/v39n3/f0905318.gif" /></p>     
<p align="justify"><font face="verdana" size="2">Como se observa los valores promedios medidos no sobrepasan los l&iacute;mites recomendados por la ICNIRP.Con respecto a los valores que pudieran causar interferencia con los equipos m&eacute;dicos y su funcionamiento, se puede plantear que los promedios encontrados, no sobrepasan al valor que establece la norma IEC60601-1-2 (2004), pero que est&aacute; dentro del principio de evitaci&oacute;n prudente mantener una vigilancia sobre este aspecto.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="3"><b>CONCLUSIONES</b></font></p>     <p align="justify"><font face="verdana" size="2">Se puede concluir, observando los resultados obtenidos, que la contaminaci&oacute;n electromagn&eacute;tica est&aacute; presente independientemente de las condiciones de trabajo. Que los valores de radiaci&oacute;n que llegan a las personas en una misma &aacute;rea pueden ser diferentes, pues esta depende de si est&aacute;n en movimiento o ubicados en un mismo lugar y del tiempo en que se encuentren en &eacute;l.</font></p>     <p align="justify"><font face="verdana" size="2">Tambi&eacute;n se puede plantear que al comparar, con las recomendaciones de la ICNIRP 2010, los valores de campo electromagn&eacute;tico y sus promedios, son inferiores a los recomendados, por lo que no existen problemas de riesgo por exceso de radiaci&oacute;n.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="3"><b>REFERENCIAS </b></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;1&#93; V. P. Korobkova., M. Yu. A, M. D. Stolarov, and Y. A. Yakub., "Influence of the electric field in 500 and 750 kV switchyards on maintenance staff and means for its protection," <i>CIGRE Paper </i>vol. 23, 1972.&#91;consultado diciembre 2016 &#93;,disponible en : <a href="http://www.cigre.org/Events" target="_blank">http://www.cigre.org/Events</a>, <a href="https://e-cigre.org/publication/23-06_1972-influence-of-electric-field-in-500-and-750-kv-switchyards-on-maintenance-staff-and-means-for-its-protection" target="_blank">https://e-cigre.org/publication/23-06_1972-influence-of-electric-field-in-500-and-750-kv-switchyards-on-maintenance-staff-and-means-for-its-protection</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;2&#93; Wertheimer N and Leeper E, " Fetal loss associated with two seasonal sources of electromagnetic field exposure.," <i>Am J Epidemiol, </i>vol. 129, p. 220-4, 1989, &#91;cosultado en febrero del 2017&#93; Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/2910064" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/2910064</a>.    </font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;3&#93; Savitz DA, Pearce NE, and Poole C, "Methodological issues in the epidemiology of electromagnetic fields and cancer,"<i> Epidemiol Rev </i>vol. 11, pp. 59-78, 1989.ISS3N 019936X, &#91;consultado en Febrero de 2017&#93;.Disponible en: <a href="https://www.scopus.com/record/display.uri?eid=2-s2.0- 0024459499&amp;origin=inward&amp;txGid=7a11066cee58f812af8c289cf04e2caf" target="_blank">https://www.scopus.com/record/display.uri?eid=2-s2.0- 0024459499&amp;origin=inward&amp;txGid=7a11066cee58f812af8c289cf04e2caf</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;4&#93; London SJ, Thomas DC, and Bowman JD et al, "Exposure to residential and magnetic fields and risk of childhood leukemia," <i>Am J Epidemiol, </i>vol. 134, p. 923-37, 1991. &#91;consultado en enero de 2017&#93;, disponible en: <a href="https://academic.oup.com/aje/article-abstract/134/9/923/185381?redirectedFrom=fulltext" target="_blank">https://academic.oup.com/aje/article-abstract/134/9/923/185381?redirectedFrom=fulltext</a>, <a href="https://doi.org/10.1093/oxfordjournals.aje.a116176" target="_blank">https://doi.org/10.1093/oxfordjournals.aje.a116176</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;5&#93; Feychting M and Ahlbom A, "Magnetic fields and cancer in children residing near Swedish high-voltage power lines," <i>Am J Epidemiol </i>vol. 138, p. 467-81), 1993.&#91;consultado en septiembre 2016&#93;, disponible en : <a href="https://academic.oup.com/aje/article-abstract/138/7/467/151494" target="_blank">https://academic.oup.com/aje/article-abstract/138/7/467/151494</a>; <a href="https://doi.org/10.1093/oxfordjournals.aje.a116881" target="_blank">https://doi.org/10.1093/oxfordjournals.aje.a116881</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;6&#93; R. Welti, "La interacci&oacute;n de campos electromagn&eacute;ticos de ebf con sistemas biol&oacute;gicos," in <i>Segundas Jornadas de Trabajos con Tensi&oacute;n</i>, Rosario, 1999 &#91;consultado en diciembre de 2016&#93; disponible en: <a href="http://www.fceia.unr.edu.ar/fceia1/publicaciones/numero6/articulo2/Campos_Electro.htm" target="_blank">http://www.fceia.unr.edu.ar/fceia1/publicaciones/numero6/articulo2/Campos_Electro.htm</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;7&#93; M&eacute;ndez Alberto, Rom&aacute;n Francisco, and Ram&iacute;rez Antonio, "Alteraciones fisiol&oacute;gicas por exposici&oacute;n cr&oacute;nica a intensos campos electromagn&eacute;ticos no ionizantes," <i>Acta M&eacute;dica Colombiana, </i>vol. 20, 1995. ISSN: 0120-2448, &#91;consultado en enero de 2017&#93;, disponible en : <a href="http://www.actamedicacolombiana.com/anexo/articulos/v20n5a2.pdf" target="_blank">http://www.actamedicacolombiana.com/anexo/articulos/v20n5a2.pdf</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;8&#93; N. J. Cherry, "EMF/EMR reduces melatonin in animals and people," <i>Research Archive </i>2002 .&#91;consultado en enero de 2017&#93;. disponible en: <a href="https://hdl.handle.net/10182/3906" target="_blank">https://hdl.handle.net/10182/3906</a>. <a href="http://www.neilcherry.nz/documents/90_b1_EMR_Reduces_Melatonin_in_Animals_and_People.pdf" target="_blank">http://www.neilcherry.nz/documents/90_b1_EMR_Reduces_Melatonin_in_Animals_and_People.pdf</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;9&#93; U. Fragopoulou, Y. Grigoriev, O. Johansson, L. Margaritis, L. Morgan, E. Richter<i>, et al.</i>, "Panel cient&iacute;fico sobre riesgos electromagn&eacute;ticos campo de la salud: elementos de consenso, recomendaciones y fundamentos.," <i>Rev Salud Ambiental., </i>vol. 25, p. 307-17, 2010. &#91;consultado en enero2017&#93; disponible en : <a href="http://www.ncbi.nlm.nih.gov/pubmed/21268443" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/21268443</a>, <a href="http://emfsafetynetwork.org/wp-content/uploads/2011/02/Scientific-panel-on-EMF-Health-Risks.pdf" target="_blank">http://emfsafetynetwork.org/wp-content/uploads/2011/02/Scientific-panel-on-EMF-Health-Risks.pdf</a>.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">&#91;10&#93; J. F. . Bolte, C. Baliatsas, T. Eikelboom, and I. van Kamp, "Everyday exposure to power frequency magnetic fields and associations with non-specific physical symptoms," <i>Environmental Pollution </i>vol. 196, p. 224-229, 2014, doi:10.1016/j.envpol.2014.10.011,&#91;consultado en noviembre de 2016&#93;, disponible en: <a href="https://www.emf-portal.org/en/article/26173" target="_blank">https://www.emf-portal.org/en/article/26173</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;11&#93; K. K. . Karipidis, "Assessment of bias in a survey of residential magnetic fields in Melbourne, Australia," <i>Radiat Prot Dosimetry, </i>vol. 163, p. 92-101, 2015.DOI: 10.1093/rpd/ncu147, &#91;consultado en noviembre de 2016&#93;, disponible en : <a href="https://www.ncbi.nlm.nih.gov/pubmed/24789916" target="_blank">https://www.ncbi.nlm.nih.gov/pubmed/24789916</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;12&#93; M. &Aacute;ngel Solano V&eacute;rez and J. S&aacute;iz Ipi&ntilde;a, "Efectos biol&oacute;gicos del campo electromagn&eacute;tico," in <i>Conceptos b&aacute;sicos de Electromagnetismo</i>, ed. Espa&ntilde;a Universidad De Cantabria, 2015, p. 37&#91;consultado en diciembre de 2016&#93;, disponiblee en: <a href="https://ocw.unican.es/pluginfile.php/1926/course/section/2221/apuntes_4.pdf" target="_blank">https://ocw.unican.es/pluginfile.php/1926/course/section/2221/apuntes_4.pdf</a></font><p align="justify"><font face="verdana" size="2">&#91;13&#93; ICNIRP, "GUIDELINES FOR LIMITING EXPOSURE TO TIME VARYING ELECTRIC AND MAGNETIC FIELDS (1 HZ &ndash; 100 kHZ),," <i>HEALTH PHYSICS, </i>vol. 99, p. 818-836, 2010.&#91;consultado en septiembre de 2016&#93;, disponible en : <a href="https://www.icnirp.org/cms/upload/publications/ICNIRPLFgdl.pdf" target="_blank">https://www.icnirp.org/cms/upload/publications/ICNIRPLFgdl.pdf</a></font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;14&#93; R. Guzm&aacute;n Pi&ntilde;eiro, C. Barcel&oacute; P&eacute;rez, N. Taureaux D&iacute;az, G. Reyes Secades, and I. Moncada Rodr&iacute;guez, "Estudio caso-control sobre factores de riesgo de la leucemia infantil en Ciudad de La Habana," <i>Rev Cubana Hig Epidemiol, </i>vol. 45, 2007. &#91;consultado en Septiembre de 2016&#93;, disponible en : <a href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1561-30032007000100006" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1561-30032007000100006</a>, ISSN 1561-3003</font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;15&#93; R. Su&aacute;rez Cabrera, G. M. L&oacute;pez Pumar, N. Cabrera Cruz, and O. Sarduy Vega, "Estudio de mortalidad entre miembros de la Asociaci&oacute;n Nacional de Jubilados El&eacute;ctricos de Cuba. Ciudad de la Habana 1990-2003," <i>Revista Cubana de Salud y Trabajo, </i>vol. 8, p. 22-27, 2007. &#91;consultado en enero de 2017&#93; disponible en : . <a href="http://bvs.sld.cu/revistas/rst/vol8_1_07/rst04107.pdf" target="_blank">http://bvs.sld.cu/revistas/rst/vol8_1_07/rst04107.pdf</a> , ISSN 1991-9395</font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;16&#93; A. Hidalgo de Paz, M. Gonz&aacute;lez Deben, and A. Qui&ntilde;onez Ceballos, "Acci&oacute;n del campo magn&eacute;tico de baja frecuencia en la cicatrizaci&oacute;n de la piel, ," <i>Rev Cubana Invest Biom&eacute;d, </i>vol. 20, 2001.&#91;consultado en septiembre de 2016&#93;, disponible en : <a href="http://scielo.sld.cu/pdf/ibi/v20n3/ibi03301.pdf" target="_blank">http://scielo.sld.cu/pdf/ibi/v20n3/ibi03301.pdf</a>, ISSN 1561-3011.    </font></p>     <!-- ref --><p align="justify"><font face="verdana" size="2">&#91;17&#93; J. L. P&eacute;rez Alejo and R. Miranda Leyva, "Radiaciones electromagn&eacute;ticas y salud en la investigaci&oacute;n m&eacute;dica,," <i>Revista Cubana de Medicina Militar, </i>vol. 39, p. 35-43, 2010&#91;consultado en septiembre de 2016&#93;, disponible en : <a href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0138-65572010000100005" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0138-65572010000100005</a>, ISSN 1561-3046.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font face="verdana" size="2">&#91;18&#93; M. Castro, R. de la Caridad Perera, J. Pedrouzo, and A. Escobar, "Medici&oacute;n de campos electromagn&eacute;ticos en redes de distribuci&oacute;n: Experiencias en Cuba," <i>Ingenier&iacute;a Energ&eacute;tica, </i>vol. XXVII, p. 40-46, 2006. &#91;consultado en septiembre de 2016&#93;, disponible en : <a href="http://scielo.sld.cu/scielo.php?script=sci_serial&amp;pid=1815-5901" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_serial&amp;pid=1815-5901</a>, ISSN 1815-5901</font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;19&#93; M. Castro, G. Aponte, R. d. l. C. de la Caridad Perera, A. Escobar, J. Pedrouzo, and D. Cortina, "Campos electromagn&eacute;ticos y salud: Exposici&oacute;n a CEM de baja frecuencia en oficinas y laboratorios de computaci&oacute;n,"<i> Rev Energ&eacute;tica, </i>vol. XXVIII, 2007. &#91;consultado en septiembre 2016&#93;, disponible en : <a href="http://scielo.sld.cu/scielo.php?script=sci_serial&amp;pid=1815-5901" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_serial&amp;pid=1815-5901</a>, ISSN 1815-5901</font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;20&#93; M. Revueltas Ag&uuml;ero, I. Avila Roque, R. Baqu&eacute;s Merino, and R. C. Beltr&aacute;n Reguera, "Los campos electromagn&eacute;ticos de frecuencia extremadamente baja y su impacto sobre la salud de los seres humanos," <i>Revista Cubana de Higiene y Epidemiolog&iacute;a, </i>vol. 52, p. 210-227, 2014. &#91;consultado en septiembre de 2016&#93;, disponible en : <a href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1561-30032014000200007" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1561-30032014000200007</a>, ISSN 1561-3003</font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;21&#93; D. De&aacute;s Yero, F. Gilart Gonz&aacute;lez, and L. Beira Fontaine, "Caracterizaci&oacute;n del ambiente electromagn&eacute;tico en Salas de Rehabilitaci&oacute;n," in <i>Convenci&oacute;n Internacional de Ciencias T&eacute;cnicas</i>, MEDISAN vol.20 no.8, Cuba, 2016. &#91;consultado en septiembre de 2016&#93;, disponible en : <a href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1561-30032014000200007" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1561-30032014000200007</a>, ISSN 1561-3003</font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;22&#93; D. De&aacute;s Yero, F. Gilart Gonz&aacute;lez, and D. Quintana Revilla, "Caracterizaci&oacute;n de los niveles de exposici&oacute;n a campos electromagn&eacute;ticos durante el tratamiento con diatermia," <i>MEDISAN, </i>vol. 17, p. 908, 2013. &#91;consultado en septiembre 2016&#93;, disponible en <a href="http://scielo.sld.cu/scielo.php?pid=S1029-30192013000600004&amp;script=sci_abstract" target="_blank">http://scielo.sld.cu/scielo.php?pid=S1029-30192013000600004&amp;script=sci_abstract</a>, ISSN 1029-3019</font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;23&#93; A. Escobar-Ordo&ntilde;ez, J. O. Silva, and H. Cadavid, "Mapeo del Campo Magn&eacute;tico de Frecuencia Industrial en un Ambiente Hospitalario," <i>Revista Tecnol&oacute;gicas, </i>vol. 24, 2010. p. 71-83 ISSN-e 0123-7799, &#91;consultado en septiembre 2016&#93;, disponible en: <a href="https://dialnet.unirioja.es/servlet/articulo?codigo=5062910" target="_blank">https://dialnet.unirioja.es/servlet/articulo?codigo=5062910</a></font><!-- ref --><p align="justify"><font face="verdana" size="2">&#91;24&#93; A. E. H. B. Guillermo Aponte, Alberto Mora, "Evaluaci&oacute;n del campo magn&eacute;tico al que est&aacute;n expuestos los trabajadores de subestaciones y circuitos energizados de las empresas de energ&iacute;a," in <i>III Congreso Internacional sobre Trabajos con Tensi&oacute;n y Seguridad en Transmisi&oacute;n y Distribuci&oacute;n de Energ&iacute;a El&eacute;ctrica 17 al 20 de abril de 2007</i>, Potrero de los Funes, Argentina 2007. &#91;consultado en septiembre 2016&#93;, disponible en: <a href="http://sg.cier.org.uy/Publicaciones/Revista.nsf/0a293b20eacdf8a903257133003ea67d/2c086a23d2f768068325769c0063af96/$FILE/02_EvaluacionCMagnetico.pdf" target="_blank">http://sg.cier.org.uy/Publicaciones/Revista.nsf/0a293b20eacdf8a903257133003ea67d/2c086a23d2f768068325769c0063af96/$FILE/02_EvaluacionCMagnetico.pdf</a></font><p align="justify">&nbsp;</p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="2">Recibido: 1/1/2018</font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font face="verdana" size="2">Aprobado: 1/5/2018</font></p>     <p align="justify">&nbsp;</p>     <p align="justify">&nbsp;</p>     <p align="justify"><font face="verdana" size="2"><i>Janet Carvajal de la Osa</i>, Universidad Tecnol&oacute;gica de la Habana, Cujae, Cuba. E-mail: <a href="mailto:janetco@automatica.cujae.edu.cu">janetco@automatica.cujae.edu.cu</a></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Korobkova]]></surname>
<given-names><![CDATA[V. P.]]></given-names>
</name>
<name>
<surname><![CDATA[Yu]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Stolarov]]></surname>
<given-names><![CDATA[A, M. D]]></given-names>
</name>
<name>
<surname><![CDATA[Yakub]]></surname>
<given-names><![CDATA[Y. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of the electric field in 500 and 750 kV switchyards on maintenance staff and means for its protection]]></article-title>
<source><![CDATA[]]></source>
<year>1972</year>
<volume>23</volume>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wertheimer]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Leeper]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fetal loss associated with two seasonal sources of electromagnetic field exposure]]></article-title>
<source><![CDATA[]]></source>
<year>1989</year>
<volume>129</volume>
<page-range>220-4</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savitz]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Pearce]]></surname>
<given-names><![CDATA[NE]]></given-names>
</name>
<name>
<surname><![CDATA[Poole]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Methodological issues in the epidemiology of electromagnetic fields and cancer]]></article-title>
<source><![CDATA[]]></source>
<year>1989</year>
<volume>11</volume>
<page-range>59-78</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[London]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
<name>
<surname><![CDATA[Thomas]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
<name>
<surname><![CDATA[Bowman]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Exposure to residential and magnetic fields and risk of childhood leukemia]]></article-title>
<source><![CDATA[]]></source>
<year>1991</year>
<volume>134</volume>
<page-range>923-37</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feychting]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ahlbom]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Magnetic fields and cancer in children residing near Swedish high-voltage power lines]]></article-title>
<source><![CDATA[]]></source>
<year>1993</year>
<volume>138</volume>
<page-range>467-81</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Welti]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La interacción de campos electromagnéticos de ebf con sistemas biológicos]]></article-title>
<source><![CDATA[Segundas Jornadas de Trabajos con Tensión]]></source>
<year>1999</year>
<publisher-loc><![CDATA[^eRosario Rosario]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alberto]]></surname>
<given-names><![CDATA[Méndez]]></given-names>
</name>
<name>
<surname><![CDATA[Francisco]]></surname>
<given-names><![CDATA[Román]]></given-names>
</name>
<name>
<surname><![CDATA[Antonio]]></surname>
<given-names><![CDATA[Ramírez]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Alteraciones fisiológicas por exposición crónica a intensos campos electromagnéticos no ionizantes]]></article-title>
<source><![CDATA[]]></source>
<year>1995</year>
<volume>20</volume>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cherry]]></surname>
<given-names><![CDATA[N. J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[EMF/EMR reduces melatonin in animals and people]]></article-title>
<source><![CDATA[]]></source>
<year>2002</year>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fragopoulou]]></surname>
<given-names><![CDATA[U.]]></given-names>
</name>
<name>
<surname><![CDATA[Grigoriev]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Johansson]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[Margaritis]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Morgan]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Richter]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Panel científico sobre riesgos electromagnéticos campo de la salud: elementos de consenso, recomendaciones y fundamentos]]></article-title>
<source><![CDATA[]]></source>
<year>2010</year>
<volume>25</volume>
<page-range>307-17</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bolte]]></surname>
<given-names><![CDATA[J. F]]></given-names>
</name>
<name>
<surname><![CDATA[Baliatsas]]></surname>
<given-names><![CDATA[C.]]></given-names>
</name>
<name>
<surname><![CDATA[Eikelboom]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[van Kamp]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Everyday exposure to power frequency magnetic fields and associations with non-specific physical symptoms]]></article-title>
<source><![CDATA[]]></source>
<year>2014</year>
<volume>196</volume>
<page-range>224-229</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karipidis]]></surname>
<given-names><![CDATA[K. K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment of bias in a survey of residential magnetic fields in Melbourne, Australia]]></article-title>
<source><![CDATA[]]></source>
<year>2015</year>
<volume>163</volume>
<page-range>92-101</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Solano Vérez]]></surname>
<given-names><![CDATA[M. Ángel]]></given-names>
</name>
<name>
<surname><![CDATA[Sáiz Ipiña]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Efectos biológicos del campo electromagnético]]></article-title>
<source><![CDATA[Conceptos básicos de Electromagnetismo]]></source>
<year>2015</year>
<page-range>37</page-range><publisher-name><![CDATA[España Universidad De Cantabria]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="">
<collab>ICNIRP</collab>
<article-title xml:lang="en"><![CDATA[GUIDELINES FOR LIMITING EXPOSURE TO TIME VARYING ELECTRIC AND MAGNETIC FIELDS (1 HZ - 100 kHZ)]]></article-title>
<source><![CDATA[]]></source>
<year>2010</year>
<volume>99</volume>
<page-range>818-836</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guzmán Piñeiro]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Barceló Pérez]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Taureaux Díaz]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Reyes Secades]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Moncada Rodríguez]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Estudio caso-control sobre factores de riesgo de la leucemia infantil en Ciudad de La Habana]]></article-title>
<source><![CDATA[]]></source>
<year>2007</year>
<volume>45</volume>
</nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Suárez Cabrera]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[López Pumar]]></surname>
<given-names><![CDATA[G. M]]></given-names>
</name>
<name>
<surname><![CDATA[Cabrera Cruz]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Sarduy Vega]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estudio de mortalidad entre miembros de la Asociación Nacional de Jubilados Eléctricos de Cuba. Ciudad de la Habana 1990-2003]]></article-title>
<source><![CDATA[]]></source>
<year>2007</year>
<volume>8</volume>
<page-range>22-27</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hidalgo de Paz]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[González Deben]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Quiñonez Ceballos]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Acción del campo magnético de baja frecuencia en la cicatrización de la piel]]></article-title>
<source><![CDATA[]]></source>
<year>2001</year>
<volume>20</volume>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez Alejo]]></surname>
<given-names><![CDATA[J. L]]></given-names>
</name>
<name>
<surname><![CDATA[Miranda Leyva]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Radiaciones electromagnéticas y salud en la investigación médica]]></article-title>
<source><![CDATA[]]></source>
<year>2010</year>
<volume>39</volume>
<page-range>35-43</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Castro]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Perera]]></surname>
<given-names><![CDATA[R. de la Caridad]]></given-names>
</name>
<name>
<surname><![CDATA[Pedrouzo]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Escobar]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Medición de campos electromagnéticos en redes de distribución: Experiencias en Cuba]]></article-title>
<source><![CDATA[]]></source>
<year>2006</year>
<volume>XXVII</volume>
<page-range>40-46</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Castro]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Aponte]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Perera]]></surname>
<given-names><![CDATA[R. d. l. C. de la Caridad]]></given-names>
</name>
<name>
<surname><![CDATA[Escobar]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Pedrouzo]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Cortina]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Campos electromagnéticos y salud: Exposición a CEM de baja frecuencia en oficinas y laboratorios de computación]]></article-title>
<source><![CDATA[]]></source>
<year>2007</year>
<volume>XXVIII</volume>
</nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Revueltas Agüero]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Avila Roque]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Baqués Merino]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Beltrán Reguera]]></surname>
<given-names><![CDATA[R. C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Los campos electromagnéticos de frecuencia extremadamente baja y su impacto sobre la salud de los seres humanos]]></article-title>
<source><![CDATA[]]></source>
<year>2014</year>
<volume>52</volume>
<page-range>210-227</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Deás Yero]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gilart González]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Beira Fontaine]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Caracterización del ambiente electromagnético en Salas de Rehabilitación]]></article-title>
<source><![CDATA[]]></source>
<year>2016</year>
<volume>20</volume>
<numero>8</numero>
<issue>8</issue>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Deás Yero]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Gilart González]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Quintana Revilla]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Caracterización de los niveles de exposición a campos electromagnéticos durante el tratamiento con diatermia]]></article-title>
<source><![CDATA[]]></source>
<year>2013</year>
<volume>17</volume>
<page-range>908</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Escobar-Ordoñez]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Silva]]></surname>
<given-names><![CDATA[J. O.]]></given-names>
</name>
<name>
<surname><![CDATA[Cadavid]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Mapeo del Campo Magnético de Frecuencia Industrial en un Ambiente Hospitalario]]></article-title>
<source><![CDATA[]]></source>
<year>2010</year>
<volume>24</volume>
<page-range>71-83</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guillermo Aponte]]></surname>
<given-names><![CDATA[A. E. H. B]]></given-names>
</name>
<name>
<surname><![CDATA[Mora]]></surname>
<given-names><![CDATA[Alberto]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Evaluación del campo magnético al que están expuestos los trabajadores de subestaciones y circuitos energizados de las empresas de energía]]></article-title>
<source><![CDATA[III Congreso Internacional sobre Trabajos con Tensión y Seguridad en Transmisión y Distribución de Energía Eléctrica]]></source>
<year>2007</year>
<publisher-loc><![CDATA[Potrero de los Funes ]]></publisher-loc>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>