<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1993-8012</journal-id>
<journal-title><![CDATA[Minería y Geología]]></journal-title>
<abbrev-journal-title><![CDATA[Min. Geol.]]></abbrev-journal-title>
<issn>1993-8012</issn>
<publisher>
<publisher-name><![CDATA[EDUM. Universidad de Moa]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1993-80122022000300288</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Análisis comparativo del rendimiento térmico de un colector solar de placa plana variando el tipo de vidrio en la cubierta]]></article-title>
<article-title xml:lang="en"><![CDATA[Comparative analysis of the thermal efficiency of a flat plate solar collector varying the glass type in the cover]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Albarracín-Álvarez]]></surname>
<given-names><![CDATA[Mauro Darío]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Torres-Tamayo]]></surname>
<given-names><![CDATA[Enrique]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Laurencio-Alfonso]]></surname>
<given-names><![CDATA[Héctor Luis]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Técnica de Cotopaxi  ]]></institution>
<addr-line><![CDATA[ Latacunga]]></addr-line>
<country>Ecuador</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2022</year>
</pub-date>
<volume>38</volume>
<numero>3</numero>
<fpage>288</fpage>
<lpage>300</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1993-80122022000300288&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1993-80122022000300288&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1993-80122022000300288&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN Se realizó un análisis comparativo del rendimiento térmico en colectores solares de placa plana para el calentamiento de aire debido a la radiación solar incidente. Se utilizaron dos colectores solares de placa plana y cubierta de vidrio convencional oscuro y claro, respectivamente, lo que permitió determinar el efecto de la radiación solar incidente en la temperatura de salida del aire. Se experimentó en igualdad de condiciones con toma de datos en tiempo real cada minuto durante seis horas al día y en cuatro condiciones: sin aire forzado, con aire forzado a 0,033 kg/s, 0,5 kg/s y 0,061 kg/s. La experimentación permitió definir que la aplicación de vidrio oscuro disminuye el rendimiento térmico; los mejores valores se obtienen al utilizar vidrio claro, la temperatura de salida obtenida alcanza valores promedio de 8,26 °C sin aire forzado. El rendimiento térmico comparativo entre los colectores solares con la cubierta de vidrio claro y oscuro muestra valores que alcanzan el 12 % en cubiertas de vidrio claro, los valores de radiación solar incidente experimentales variaron entre 200 W/m2 y 1 500 W/m2.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT A comparative analysis of the thermal efficiency of flat plate solar collectors for air heating due to incident solar radiation was carried out. Two flat plate solar collectors and conventional cover of dark and clear glass were used, which allowed determining the incidence of incident solar radiation on the air outlet temperature. Experiments were carried out under equal conditions with real-time data collection every minute for six hours a day and four conditions: without forced air, with forced air at 0,033 kg/s, 0,5 kg/s and 0,061 kg/s. The experimentation allowed defining that the application of dark glass decreases the thermal efficiency; the best values are obtained when using clear glass, the outlet temperature obtained reaches average values of 8,26 °C without forced air. The comparative thermal performance between solar collectors with clear and dark glass covers shows values that reach 12 % in clear glass covers, the experimental incident solar radiation values varied between 200 W/m2 and 1 500 W/m2.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[colector solar de placa plana]]></kwd>
<kwd lng="es"><![CDATA[eficiencia térmica]]></kwd>
<kwd lng="es"><![CDATA[radiación solar incidente]]></kwd>
<kwd lng="en"><![CDATA[flat plate solar collector]]></kwd>
<kwd lng="en"><![CDATA[thermal efficiency]]></kwd>
<kwd lng="en"><![CDATA[incident solar radiation]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Avadhesh]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Bajpai]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[An experimental study on evacuated tube solar collector for heating of air in India]]></article-title>
<source><![CDATA[International Journal of Mechanics and Mechatronics Engineering]]></source>
<year>2011</year>
<volume>5</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1188-93</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ávila]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Mendoza]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Beltrán]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluación energética de un colector solar de placa plana de doble cubierta]]></article-title>
<source><![CDATA[Ingeniería y Desarrollo]]></source>
<year>2010</year>
<volume>27</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>93-112</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Babu]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Chinnapandian]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The performance study of a solar flat plate type air collector with natural and forced convection]]></article-title>
<source><![CDATA[Industrial Pollution Control]]></source>
<year>2017</year>
<volume>33</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1155-62</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bahrehmand]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Ameri]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Energy and exergy analysis of different solar air collector systems with natural convection]]></article-title>
<source><![CDATA[Renewable Energy]]></source>
<year>2015</year>
<volume>74</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>357-68</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bahrehmand]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Ameri]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Glolampour]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Energy and exergy analysis of different solar air collector systems with forced convection]]></article-title>
<source><![CDATA[Renewable Energy]]></source>
<year>2015</year>
<volume>83</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>1119-30</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bisen]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Dass]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Jain]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Parametric studies of top loss coefficient of double glazed flat plate solar collector]]></article-title>
<source><![CDATA[International Journal of Mechanical Engineering]]></source>
<year>2011</year>
<volume>1</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>71-8</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fudholi]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Sopian]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Mohd]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Yusof]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Thermal Efficiency of Double Pass Solar Collector with Longitudinal Fins Absorbers]]></article-title>
<source><![CDATA[American Journal of Applied Sciences]]></source>
<year>2011</year>
<volume>8</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>254-60</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gopi]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Kalam]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Experimental investigation of flat plate collector with cylindrical fins in a solar air heater]]></article-title>
<source><![CDATA[Industrial Pollution Control]]></source>
<year>2017</year>
<volume>33</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1128-31</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kayiem]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Tadahmun]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[On the natural convection heat transfer in a rectangular passage solar air heater]]></article-title>
<source><![CDATA[Solar Energy]]></source>
<year>2015</year>
<volume>112</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>310-8</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koulibaly]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Modelación de un colector solar para calentamiento de aire]]></article-title>
<source><![CDATA[Ingeniería Energética]]></source>
<year>2015</year>
<volume>XXXVI</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>282-93</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ravi]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
<name>
<surname><![CDATA[Saini]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A review on different techniques used for performance enhancement of double pass solar air heaters]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy]]></source>
<year>2016</year>
<volume>56</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>941-52</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saxena]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Sebaii]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A thermodynamic review of solar air heaters]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2015</year>
<volume>43</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>863-90</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sharma]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Som]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Exergy Based Performance Analysis of Double Flow Solar Air Heater with Corrugated Absorber]]></article-title>
<source><![CDATA[International Journal of Energy and Power Engineering]]></source>
<year>2017</year>
<volume>11</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1212-8</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tamayo]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Guadalupe]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Mediaceja]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Díaz]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Mathematical modeling of the natural solar drying process in lateritic mineral deposits]]></article-title>
<source><![CDATA[International Journal of Mechanics]]></source>
<year>2017</year>
<volume>11</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>182-7</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torres]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Morales]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Albarracín]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Laurencio]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Cooling temperature and heat transfer coefficients in cylindrical heat exchangers]]></article-title>
<source><![CDATA[International Journal of Mechanics]]></source>
<year>2021</year>
<volume>15</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>254-9</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>