<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0034-7515</journal-id>
<journal-title><![CDATA[Revista Cubana de Farmacia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Farm]]></abbrev-journal-title>
<issn>0034-7515</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0034-75152007000100003</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Método analítico por cromatografía líquida de alta resolución para el estudio de estabilidad del jarabe de loratadina 0,1 %]]></article-title>
<article-title xml:lang="en"><![CDATA[Analytical method by high resolution liquid chromatography for the stability study of loratidine syrup 0.1 %]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Torres Amaro]]></surname>
<given-names><![CDATA[Leonid]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García Peña]]></surname>
<given-names><![CDATA[Caridad M.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pardo Ruiz]]></surname>
<given-names><![CDATA[Zenia]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Centro de Investigación y Desarrollo de Medicamentos (CIDEM).  ]]></institution>
<addr-line><![CDATA[C. de La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2007</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2007</year>
</pub-date>
<volume>41</volume>
<numero>1</numero>
<fpage>0</fpage>
<lpage>0</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0034-75152007000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0034-75152007000100003&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0034-75152007000100003&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se validó un método de cromatografía líquida de alta resolución para el estudio de estabilidad del jarabe de loratadina 0,1 %. La curva de calibración en el rango de 13,6 a 3,36 µg/mL fue lineal, con un coeficiente de correlación igual a 0,99975; la prueba estadística para el intercepto y la pendiente, no significativa. El recobrado obtenido resultó de 100,2 % en el rango de concentración estudiado, y las pruebas de Cochran y Student (t), no significativas. El coeficiente de variación en el estudio de repetibilidad fue igual a 0,41 % para 10 réplicas ensayadas, mientras que en la reproducibilidad las pruebas de Fischer y Student, no significativas. El método resultó específico, lineal, preciso y exacto.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[A high resolution liquid chromatography method was validated to study the stability of loratidine syrup 0.1 %. The calibration curve in the range from 13.6 to 3.36 µg/mL was lineal, with a coefficient of correlation equal to 0.99975. The intercept and slope statistical test was not significant. The recovery obtained was 100.2 % in the concentration range studied, and the Cochran and Student (t) tests results were not important. The variation coefficient in the repeatability study was equal to 0.41 % for 10 replications assayed, whereas in the reproducibility Fischer and Student tests were not remarkable. The method proved to be specific, lineal, accurate, and exact.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Loratadina]]></kwd>
<kwd lng="es"><![CDATA[cromatografía líquida de alta resolución]]></kwd>
<kwd lng="es"><![CDATA[validación.]]></kwd>
<kwd lng="en"><![CDATA[Loratidine]]></kwd>
<kwd lng="en"><![CDATA[high resolution liquid chromatography]]></kwd>
<kwd lng="en"><![CDATA[validation.]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p>Centro de Investigaci&oacute;n y Desarrollo de Medicamentos </p> <h2 align="left">M&eacute;todo anal&iacute;tico por cromatograf&iacute;a l&iacute;quida de alta resoluci&oacute;n para el estudio de estabilidad del jarabe de loratadina 0,1 % </h2>     <p><a href="#cargo">Leonid Torres Amaro,<span class="superscript">1</span> Caridad M. Garc&iacute;a Pe&ntilde;a<span class="superscript">2</span> y Zenia Pardo Ruiz<span class="superscript">2</span> </a><a name="autor"></a></p> <h4>Resumen </h4>     <p align="justify">Se valid&oacute; un m&eacute;todo de cromatograf&iacute;a l&iacute;quida    de alta resoluci&oacute;n para el estudio de estabilidad del jarabe de loratadina    0,1 %. La curva de calibraci&oacute;n en el rango de 13,6 a 3,36 &micro;g/mL    fue lineal, con un coeficiente de correlaci&oacute;n igual a 0,99975; la prueba    estad&iacute;stica para el intercepto y la pendiente, no significativa. El recobrado    obtenido result&oacute; de 100,2 % en el rango de concentraci&oacute;n estudiado,    y las pruebas de Cochran y Student (t), no significativas. El coeficiente de    variaci&oacute;n en el estudio de repetibilidad fue igual a 0,41 % para 10 r&eacute;plicas    ensayadas, mientras que en la reproducibilidad las pruebas de Fischer y Student,    no significativas. El m&eacute;todo result&oacute; espec&iacute;fico, lineal,    preciso y exacto. </p>     <p align="justify"><strong>Palabras clave</strong>: Loratadina, cromatograf&iacute;a l&iacute;quida de alta resoluci&oacute;n, validaci&oacute;n. </p>     <p align="justify">Loratadina es un derivado piperid&iacute;nico de la azatadina, de acci&oacute;n antihistam&iacute;nica con actividad central sedativa o antimuscarina. Es indicado para aliviar los s&iacute;ntomas de las reacciones de hipersensibilidad, incluyendo la rinitis al&eacute;rgica y la urticaria cr&oacute;nica.<span class="superscript">1,2</span> </p>     <p align="justify">Existen reportes de m&eacute;todos anal&iacute;ticos por espectrofotometr&iacute;a ultravioleta para formulaciones de loratadina tabletas debido a que es un producto que absorbe intensamente en la regi&oacute;n del ultravioleta.<span class="superscript">3</span> Para el jarabe de loratadina aparecen reportes de m&eacute;todos anal&iacute;ticos por cromatograf&iacute;a l&iacute;quida de alta resoluci&oacute;n.<span class="superscript">4</span> </p>     <p align="justify">La cromatograf&iacute;a l&iacute;quida de alta resoluci&oacute;n (CLAR) ha dado la posibilidad al analista de usar esta herramienta para solucionar los inconvenientes de los m&eacute;todos espectrofotom&eacute;tricos en los estudios de estabilidad, pues adem&aacute;s de presentar una alta sensibilidad y exactitud, es en esencia un m&eacute;todo separativo; lo que permite medir con gran selectividad el compuesto deseado, siempre y cuando se encuentre un sistema cromatogr&aacute;fico que asegure una adecuada separaci&oacute;n.<span class="superscript">4</span> </p>     <p align="justify">La validaci&oacute;n es el proceso establecido para la obtenci&oacute;n de pruebas documentadas de que el m&eacute;todo es lo suficientemente fiable para producir el resultado.<span class="superscript">5-8</span> </p>     <p align="justify">En el presente trabajo se describe y valida un m&eacute;todo anal&iacute;tico por CLAR a fin de cuantificar el principio activo para los estudios de estabilidad del jarabe de loratadina 0,1 %. </p> <h4 align="justify">M&eacute;todos </h4>     <p align="justify">La sustancia de referencia qu&iacute;mica de loratadina fue suministrada por el grupo de sustancias de referencia del Centro de Investigaci &oacute;n y Desarrollo de Medicamentos (CIDEM). El producto terminado en forma de jarabe al 0,1 %, fue elaborado en la Grupo de Formas terminadas, perteneciente al CIDEM. Todos los reactivos utilizados fueron de grado HPLC. </p>     ]]></body>
<body><![CDATA[<p align="justify">En el ensayo se emple&oacute; un cromat&oacute;grafo (KNAUER) con detector UV/VIS (KNAUER) ajustado a 254 nm, un dosificador (<em>loop</em>) de 20 µL e integrador (SHIMADZU CR6A), con una sensibilidad de 0,08 AUFS. La separaci&oacute;n se realiz&oacute; isocr&aacute;ticamente sobre una columna Licrospher RP 18, 250 mm x 4 mm, 10 µm. La fase m&oacute;vil utilizada consisti&oacute; en una mezcla filtrada y desgasificada de metanol: dihidrogenofosfato de potasio 0,013 mol/L, ajustada a pH 7,6-8,0 con hidr&oacute;xido de potasio 0,1 mol/L en proporci&oacute;n 8/2 (v/v), con una velocidad de flujo de 2,0 µL/min. Todos los reactivos utilizados fueron de calidad anal&iacute;tica (MERCK, Alemania). </p>     <p align="justify">Con el objetivo de evaluar la especificidad del m&eacute;todo cromatogr&aacute;fico, se someti&oacute; el producto terminado de la formulaci&oacute;n seleccionada a oxidaci&oacute;n con unas gotas de per&oacute;xido de hidr&oacute;geno al 33 %, a hidr&oacute;lisis con hidr&oacute;xido de sodio 1 mol/L y &aacute;cido clorh&iacute;drico 1 mol/L (1:1), coloc&aacute;ndose las muestras durante 30 min en un ba&ntilde;o de agua destilada a 100 &deg;C. Previamente se analiz&oacute; la sustancia de referencia y el placebo sin degradar y posteriormente fueron evaluadas por cromatograf&iacute;a l&iacute;quida de alta resoluci&oacute;n.<span class="superscript">9</span> Las muestras fueron diluidas con la fase m&oacute;vil de manera que se obtuviera una concentraci&oacute;n similar a 20 µg/mL. </p>     <p align="justify">Se comprob&oacute; la linealidad del sistema, preparando muestras a diferentes niveles de loratadina que representan el 68,100,128,148, 168 % de la concentraci&oacute;n te&oacute;rica del principio activo en el jarabe, evalu&aacute;ndose el coeficiente de correlaci&oacute;n, la ecuaci&oacute;n de la recta, la prueba de linealidad y la prueba de proporcionalidad.<span class="superscript">10</span> </p>     <p align="justify">La repetibilidad se realiz&oacute; con una muestra homog&eacute;nea y com&uacute;n del lote 46 que representa el 100 % de la cantidad te&oacute;rica declarada. La precisi&oacute;n intermedia <strong></strong>se realiz&oacute; con la misma muestra homog&eacute;nea de concentraci&oacute;n &uacute;nica, efectu&aacute;ndose las valoraciones en 2 equipos diferentes, 2 d&iacute;as diferentes; para su evaluaci&oacute;n se realiz&oacute; un an&aacute;lisis de varianza, a trav&eacute;s de la determinaci&oacute;n del coeficiente de variaci&oacute;n, prueba de Fischer y de la t de Student.<span class="superscript">11</span> </p>     <p align="justify">El estudio de exactitud se desarroll&oacute; por el m&eacute;todo de recuperaci&oacute;n, mediante la preparaci&oacute;n de muestras con diferentes niveles de loratadina que representan el 80, 90, 110 y 120 % respectivamente de la concentraci&oacute;n te&oacute;rica del principio activo en el producto terminado, evalu&aacute;ndose los par&aacute;metros de la prueba de la t de Student, de Cochran, ecuaci&oacute;n de la recta y coeficiente de correlaci&oacute;n.<span class="superscript">10</span> </p>     <p align="justify">Todos los resultados obtenidos fueron evaluados estad&iacute;sticamente con la ayuda del programa Microcal Origin 5.0 para Windows. </p> <h4 align="justify">Resultados </h4>     <p align="justify">La figura muestra los resultados obtenidos en el estudio de especificidad del m&eacute;todo. Como se observa en el cromatograma correspondiente a la muestra placebo no se obtuvo ninguna se&ntilde;al en la zona de inter&eacute;s, al ser comparado con la se&ntilde;al obtenida para la soluci&oacute;n est&aacute;ndar de referencia y de la muestra, lo cual indica que los excipientes o sustancias auxiliares de la soluci&oacute;n no interfieren en la determinaci&oacute;n del principio activo. En cuanto a las muestras sometidas a condiciones dr&aacute;sticas de: hidr&oacute;lisis b&aacute;sica, hidr&oacute;lisis &aacute;cida y H<span class="subscript">2</span>O<span class="subscript">2</span>. </p>     <p align="center"><a href="/img/revistas/far/v41n1/f0103107.jpg"><img src="/img/revistas/far/v41n1/f0103107.jpg" width="203" height="312" border="0"></a></p>     
<p align="center"><strong>Fig</strong>. Estudio de especificidad. Cromatogramas: A) sustancia de referencia qu&iacute;mica;     <br> B) placebo; C) muestra; D) muestra en medio &aacute;cido; E) muestra en medio b&aacute;sico. </p>     ]]></body>
<body><![CDATA[<p align="justify">Simult&aacute;neamente se realiz&oacute; un <em>scanning </em> al pico correspondiente al principio activo en un rango de 200 a 500 nm, obteni&eacute;ndose una pureza del 99,6 %. </p>     <p align="justify">La ecuaci&oacute;n de la recta de la curva de calibraci&oacute;n en el rango de concentraciones entre 13,6 a 33,6 &micro;g/mL, se expresa seg&uacute;n y = 0,9815 X + 0,0136, con un coeficiente de correlaci&oacute;n lineal de 0,99854. Al aplicar la prueba de significaci&oacute;n del intercepto se obtuvo una t<span class="subscript">cal</span> = 3,91 para una t<span class="subscript">tab</span> = 4,30. Cuando se aplic&oacute; la prueba de linealidad mediante los coeficientes de variaci&oacute;n de los factores de respuesta CV<span class="subscript">f</span> se obtuvo como resultado un coeficiente de variaci&oacute;n CV= 2,1 %. <strong></strong></p>     <p align="justify">Los resultados del estudio de la precisi&oacute;n, realizado 2 d&iacute;as diferentes por 2 analistas diferentes, aparecen en la tabla 1. </p>     <p align="center"><strong>Tabla 1</strong>. Resultados del estudio de la precisi&oacute;n </p>     <div align="center">   <table width="89%" cellpadding="0" cellspacing="3">     <tr>       <td colspan="2" valign="top">    <p align="center">Repetibilidad</p></td>       <td colspan="4" valign="top">    <p align="center">Reproducibilidad </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">Muestras </p></td>       <td width="121" valign="top">    <p align="center">% </p></td>       <td colspan="2" valign="top">    <p align="center">Analista 1</p></td>       <td colspan="2" valign="top">    ]]></body>
<body><![CDATA[<p align="center">Analista 2</p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">1 </p></td>       <td width="121" valign="top">    <p align="center">98,0 </p></td>       <td width="98" valign="top">    <p align="center">D&iacute;a 1 </p></td>       <td width="100" valign="top">    <p align="center">D&iacute;a 2 </p></td>       <td width="103" valign="top">    <p align="center">D&iacute;a 1 </p></td>       <td width="101" valign="top">    <p align="center">D&iacute;a 2 </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">2 </p></td>       <td width="121" valign="top">    <p align="center">98,1 </p></td>       <td width="98" valign="top">    <p align="center">100,4 % </p></td>       <td width="100" valign="top">    ]]></body>
<body><![CDATA[<p align="center">100,2 % </p></td>       <td width="103" valign="top">    <p align="center">97,8 % </p></td>       <td width="101" valign="top">    <p align="center">97,4 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">3 </p></td>       <td width="121" valign="top">    <p align="center">98,5 </p></td>       <td width="98" valign="top">    <p align="center">97,8 % </p></td>       <td width="100" valign="top">    <p align="center">97,6 % </p></td>       <td width="103" valign="top">    <p align="center">98,3 % </p></td>       <td width="101" valign="top">    <p align="center">98,5 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">4 </p></td>       <td width="121" valign="top">    ]]></body>
<body><![CDATA[<p align="center">97,9 </p></td>       <td width="98" valign="top">    <p align="center">98,5 % </p></td>       <td width="100" valign="top">    <p align="center">98,8 % </p></td>       <td width="103" valign="top">    <p align="center">99,1 % </p></td>       <td width="101" valign="top">    <p align="center">99,8 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">5 </p></td>       <td width="121" valign="top">    <p align="center">98,3 </p></td>       <td width="98" valign="top">    <p align="center">97,6 % </p></td>       <td width="100" valign="top">    <p align="center">97,1 % </p></td>       <td width="103" valign="top">    <p align="center">98,5 % </p></td>       <td width="101" valign="top">    ]]></body>
<body><![CDATA[<p align="center">99,3 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">6 </p></td>       <td width="121" valign="top">    <p align="center">98,2 </p></td>       <td width="98" valign="top">    <p align="center">98,6 % </p></td>       <td width="100" valign="top">    <p align="center">98,4 % </p></td>       <td width="103" valign="top">    <p align="center">98,5 % </p></td>       <td width="101" valign="top">    <p align="center">98,3 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">7 </p></td>       <td width="121" valign="top">    <p align="center">98,5 </p></td>       <td width="98" valign="top">    <p align="center">98,3 % </p></td>       <td width="100" valign="top">    ]]></body>
<body><![CDATA[<p align="center">98,5 % </p></td>       <td width="103" valign="top">    <p align="center">98,6 % </p></td>       <td width="101" valign="top">    <p align="center">98,7 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">8 </p></td>       <td width="121" valign="top">    <p align="center">99,0 </p></td>       <td width="98" valign="top">    <p align="center">98,2 % </p></td>       <td width="100" valign="top">    <p align="center">98,8 % </p></td>       <td width="103" valign="top">    <p align="center">98,4% </p></td>       <td width="101" valign="top">    <p align="center">98,5 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">9 </p></td>       <td width="121" valign="top">    ]]></body>
<body><![CDATA[<p align="center">98,3 </p></td>       <td width="98" valign="top">    <p align="center">X<span class="subscript">m1</span> =98,5 % </p></td>       <td width="100" valign="top">    <p align="center">X<span class="subscript">m2</span> =98,5 % </p></td>       <td width="103" valign="top">    <p align="center">X<span class="subscript">m1</span> =98,5 % </p></td>       <td width="101" valign="top">    <p align="center">X<span class="subscript">m2</span> = 98,6 % </p></td>     </tr>     <tr>       <td width="120" valign="top">    <p align="center">10 </p></td>       <td width="121" valign="top">    <p align="center">99,1 </p></td>       <td width="98" valign="top">    <p align="center">CV=0,9 % </p></td>       <td width="100" valign="top">    <p align="center">CV= 0,9 % </p></td>       <td width="103" valign="top">    <p align="center">CV= 0,4 % </p></td>       <td width="101" valign="top">    ]]></body>
<body><![CDATA[<p align="center">CV =0,74 % </p></td>     </tr>     <tr>       <td colspan="2" rowspan="3" valign="top">    <div align="center">X media = 98,4 %     <br>     DSR= 0,4 %     <br>     CV= 0,41 % </div></td>       <td colspan="2" valign="top">    <div align="center">F<span class="subscript">cal</span> =1,6 </div></td>       <td colspan="2" valign="top">    <div align="center">t<span class="subscript">cal</span> = 0,253 </div></td>     </tr>     <tr>       <td colspan="2" valign="top">    <div align="center">F<span class="subscript">tab</span> (6/6; 0,05) = 4,28 </div></td>       <td colspan="2" valign="top">    <div align="center">t<span class="subscript">tab</span> (12; 0,05) = 2,18 </div></td>     </tr>     <tr>       <td colspan="4" valign="top">    <div align="center">Intervalo de confianza: 98,5 &plusmn; 0,04 % </div></td>     </tr>   </table> </div>     <p>En la tabla 2 se muestran los resultados obtenidos en el estudio de la exactitud    del m&eacute;todo. En la curva de recuperaci&oacute;n, se reportan los mg te&oacute;ricos    contra los mg pr&aacute;cticos, obteni&eacute;ndose la ecuaci&oacute;n de la    recta: y= 1,04885 X - 1,1107, con un coeficiente de correlaci&oacute;n de 0,99624.    Al aplicar la prueba de significaci&oacute;n para conocer la influencia de la    concentraci&oacute;n (G de Cochran), se obtuvo una G<span class="subscript">cal</span>=    0,6923 para una G<span class="subscript">tab</span>= 0,8709. Al realizar la    prueba de significaci&oacute;n entre la recuperaci&oacute;n media y el 100 %    de recuperaci&oacute;n, se obtuvo una t<span class="subscript">cal</span>= 0,71    para una t<span class="subscript">tab</span>= 2,45 .</p>     ]]></body>
<body><![CDATA[<p align="center"><strong>Tabla 2</strong>. Resultados del estudio de exactitud </p>     <div align="center">   <table cellspacing="3" cellpadding="0">     <tr>       <td valign="top">    <p align="center">mg adicionados</p></td>       <td colspan="3" valign="top">    <p align="center">mg recuperados</p></td>       <td valign="top">    <p align="center">Recobrado (%)</p></td>       <td valign="top">    <p align="center">CV (%)</p></td>     </tr>     <tr>       <td valign="top">    <p align="center">0,01592 </p></td>       <td valign="top">    <p align="center">0,01591 </p></td>       <td valign="top">    <p align="center">0,01579 </p></td>       <td valign="top">    <p align="center">0,01579 </p></td>       <td valign="top">    ]]></body>
<body><![CDATA[<p align="center">98,6 </p></td>       <td valign="top">    <p align="center">0,50 </p></td>     </tr>     <tr>       <td valign="top">    <p align="center">0,01871 </p></td>       <td valign="top">    <p align="center">0,01825 </p></td>       <td valign="top">    <p align="center">0,01828 </p></td>       <td valign="top">    <p align="center">0,01822 </p></td>       <td valign="top">    <p align="center">101,8 </p></td>       <td valign="top">    <p align="center">1,25 </p></td>     </tr>     <tr>       <td valign="top">    <p align="center">0,02206 </p></td>       <td valign="top">    <p align="center">0,02218 </p></td>       <td valign="top">    ]]></body>
<body><![CDATA[<p align="center">0,02222 </p></td>       <td valign="top">    <p align="center">0,0222 </p></td>       <td valign="top">    <p align="center">100,52 </p></td>       <td valign="top">    <p align="center">0,023 </p></td>     </tr>     <tr>       <td valign="top">    <p align="center">0,02403 </p></td>       <td valign="top">    <p align="center">0,02411 </p></td>       <td valign="top">    <p align="center">0,02419 </p></td>       <td valign="top">    <p align="center">0,02418 </p></td>       <td valign="top">    <p align="center">100,32 </p></td>       <td valign="top">    <p align="center">0,023 </p></td>     </tr>   </table> </div>     ]]></body>
<body><![CDATA[<div align="center"></div> <h4>Discusi&oacute;n </h4>     <p align="justify">Los resultados obtenidos del an&aacute;lisis de la muestra    placebo, la soluci&oacute;n de referencia, la muestra del producto terminado    y la muestra degradada por hidr&oacute;lisis &aacute;cida, hidr&oacute;lisis    b&aacute;sica, oxidaci&oacute;n H<span class="subscript">2</span>O<span class="subscript">2</span>,    que se muestran en la figura, demuestran la especificidad del m&eacute;todo    al no presentarse interferencias de picos adicionales en la zona de eluci&oacute;n    del producto principal.<span class="superscript">6</span></p>     <p align="justify">El <em>scanning </em> realizado con el objetivo de determinar la pureza del pico de loratadina, en el rango de 200 a 500 nm demostr&oacute; que no exist&iacute;a solapamiento de otros productos de degradaci&oacute;n. </p>     <p align="justify">La curva de calibraci&oacute;n result&oacute; ser lineal en un rango de concentraciones entre 13,6 a 33,6 &micro;g/mL. </p>     <p align="justify">Al aplicar la prueba del intercepto, este result&oacute; ser    no significativo ya que la t<span class="subscript">cal</span> fue menor que    la t<span class="subscript">tab</span> para 4 g.l. y una probabilidad de 0,05.    En la prueba de linealidad mediante los coeficientes de variaci&oacute;n de    los factores de respuesta CV<span class="Estilo1">f </span>se obtuvo un coeficiente    de variaci&oacute;n menor del 5 %, lo que demuestra la adecuada linealidad de    acuerdo con el l&iacute;mite establecido, por lo que se demuestra el cumplimiento    de la linealidad en el intervalo de concentraci&oacute;n estudiado.<span class="superscript">7    </span></p>     <p align="justify">En el estudio de la repetibilidad se alcanz&oacute; un coeficiente    de variaci&oacute;n de 0,41 %, adecuado lo que nos demuestra la buena precisi&oacute;n    del m&eacute;todo, seg&uacute;n el l&iacute;mite para los m&eacute;todos cromatogr&aacute;ficos    CV <span class="Estilo1"><font face="Symbol">&pound;</font></span> 2 %.<span class="superscript">8</span>    Los valores obtenidos para el estudio de la precisi&oacute;n intermedia demuestran    que no existen diferencias significativas entre las precisiones alcanzadas por    los analistas en diferentes d&iacute;as para una probabilidad de 0,05 % ya que    el valor de F<span class="subscript">cal</span> es menor que la F<span class="subscript">tab</span>.    Al realizar la prueba de la t de Student el valor calculado result&oacute; ser    menor que el tabulado para una probabilidad de 0,05 y 8 g.l., lo cual demuestra    que no existen diferencias significativas entre las medias alcanzadas con un    nivel de significaci&oacute;n del 5 %.<span class="superscript">8</span> </p>     <p align="justify">En el rango seleccionado en el estudio de exactitud, los valores de porcentaje de recobro estuvieron dentro de los l&iacute;mites establecidos para los m&eacute;todos cromatogr&aacute;ficos (98-102 %) y los valores del coeficiente de variaci&oacute;n para cada uno de los niveles de concentraci&oacute;n estudiados resultaron ser menor que el 2 %.<span class="superscript">11</span> </p>     <p align="justify">En la influencia del factor concentraci&oacute;n sobre la variabilidad de los resultados de la exactitud al aplicar la prueba de Cochran se obtuvo que G<span class="subscript">exp</span> fue menor que la G<span class="subscript">tab</span> para una probabilidad de 005, k= 3 y n= 3; por tanto, las varianzas de las concentraciones empleadas son equivalentes y nos indican que la concentraci&oacute;n no influye en la variabilidad de estos. </p>     <p align="justify">No existen diferencias significativas entre la recuperaci&oacute;n    media (100,2 %) y el 100 % de recuperaci&oacute;n al aplicar la prueba de la    t de Student, ya que la t<span class="subscript">cal</span> fue menor que la    t<span class="subscript">tab</span> para 6 g.l. y una probabilidad de 0,05,    por lo que el m&eacute;todo es exacto. </p>     <p align="justify">La curva de recuperaci&oacute;n reportada de mg te&oacute;ricos contra los mg pr&aacute;cticos demostr&oacute; un comportamiento lineal, ya que la ecuaci&oacute;n de la recta y el coeficiente de correlaci&oacute;n se encontraron dentro de los l&iacute;mites establecidos para este ensayo. La prueba de significaci&oacute;n del intercepto result&oacute; no significativa y el valor de la pendiente no difiere significativamente de la unidad. Los valores alcanzados de la pendiente, el intercepto y el coeficiente de correlaci&oacute;n demostraron la exactitud y linealidad del m&eacute;todo.<span class="superscript">9</span> </p>     ]]></body>
<body><![CDATA[<p align="justify">En conclusi&oacute;n, el m&eacute;todo anal&iacute;tico desarrollado por CLAR para el estudio de estabilidad del jarabe de loratadina result&oacute; ser espec&iacute;fico, lineal, preciso y exacto en el intervalo de concentraciones de 13,6 y 33,6 µg/mL </p> <h4>Summary</h4> <h6 align="left">Analytical method by high resolution liquid chromatography for the stability study of loratidine <strong></strong>syrup 0.1 % </h6>     <p align="justify">A high resolution liquid chromatography method was validated    to study the stability of loratidine <strong></strong>syrup 0.1 %. The calibration    curve in the range from 13.6 to 3.36 µg/mL was lineal, with a coefficient of    correlation equal to 0.99975. The intercept and slope statistical test was not    significant. The recovery obtained was 100.2 % in the concentration range studied,    and the Cochran and Student (t) tests results were not important. The variation    coefficient in the repeatability study was equal to 0.41 % for 10 replications    assayed, whereas in the reproducibility Fischer and Student tests were not remarkable.    The method proved to be specific, lineal, accurate, and exact. </p>     <p align="justify"><strong>Key words</strong>: Loratidine, high resolution liquid chromatography, validation. </p> <h4 align="left">Referencias bibliogr&aacute;ficas <strong></strong></h4> <ol>       <li>         <div align="justify">  Goodman, Gilman, A. Las bases farmacol&oacute;gicas de la terap&eacute;utica. 3ra ed. Tomo II. La Habana: Edici&oacute;n Revolucionaria; 1994. p. 791.</div>   </li>       <li>         <div align="justify"> Martindale. The Extra Pharmacopoeia. 28 ed. London : The Pharmaceutical Press; 1989. p. 1248-9. </div>   </li>       <li>         <div align="justify"> Cromatograf&iacute;a en la Qu&iacute;mica Cl&iacute;nica. HPLC-Reactivos Merck. 1988. p. 3-16. </div>   </li>       <li>         ]]></body>
<body><![CDATA[<div align="justify"> Quattrocchi OA, Laba RF. Introducci&oacute;n a la HPLC. En Aplicaci&oacute;n y pr&aacute;ctica. Buenos Aires: Ed. Artes Gr&aacute;ficas Farro SA; 1992. p. 106-122, 284, 302-28. </div>   </li>       <li>         <div align="justify"> Castro M, Gasc&oacute;n S. Validaci&oacute;n de m&eacute;todos anal&iacute;ticos. Secci&oacute;n Catalana de AEFI. Comisi&oacute;n de normas de buena fabricaci&oacute;n y control de la calidad. Sept, 1989. p. 1-94. </div>   </li>       <li>         <div align="justify"> United States Pharmacopoeial Convention. USP 29. Validation of compendial methods. 23 ed. Rockville : Mack Printing; 2006. p. 1982-4. </div>   </li>       <li>         <div align="justify"> International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use, Validation of analytical procedures, ICH-Q2A, Geneva, 1995. </div>   </li>       <li>         <div align="justify"> International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use, Validation of analytical procedures: Methodology, ICH-Q2B, Geneva, 1996. ICH harmonized tripartite guideline. Methodology of validation of analytical method. Recomendado en Nov. 1996. </div>   </li>       <li>         ]]></body>
<body><![CDATA[<div align="justify"> Sarrio RV, Silvestre LJ. Validation of Analytical Assays and Test Methods for the Pharmaceutical Laboratory. The Regulatory Forum. Bioserch. 1996. </div>   </li>       <li>         <div align="justify"> Guidance for Industry. Analytical Procedures and Methods Validation     <br>       Chemistry, Manufacturing, and Controls Documentation. FDA/Center for Drug Evaluation and Research. 2001.</div>   </li>       <li>         <div align="justify"> Guidance for Industry. Analytical Procedure and Methods Validation. Draft Guidance. August, 2000. </div>   </li>     </ol>     <p>Recibido: 11 de octubre de 2006. Aprobado: 17 de noviembre de 2006.     <br> Lic. <em>Leonid Torres Amaro </em> Centro de Investigaci&oacute;n y Desarrollo de Medicamentos (CIDEM). Ave. 26 No. 1605 entre Boyeros y Puentes Grandes, municipio Plaza de La Revoluci&oacute;n. La Habana, CP 10 600, Cuba. Correo electr&oacute;nico:E-mail: <a href="mailto:leonid@cidem.quimefa.cu ">leonid@cidem.quimefa.cu </a></p>     <p><span class="superscript"><a href="#autor">1 </a></span><a href="#autor">Licenciado en Ciencias Farmac&eacute;uticas. Investigador Agregado.     ]]></body>
<body><![CDATA[<br>     <span class="superscript"><strong>2</strong></span> Master en Ciencias. Investigadora Agregada. </a><a name="cargo"></a></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goodman, Gilman]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Las bases farmacológicas de la terapéutica.]]></source>
<year></year>
<edition>3ra ed.</edition>
<publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Edición Revolucionaria]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2.</label><nlm-citation citation-type="book">
<source><![CDATA[Martindale.: The Extra Pharmacopoeia.]]></source>
<year>1989</year>
<edition>28 ed.</edition>
<page-range>1248-9.</page-range><publisher-loc><![CDATA[London ]]></publisher-loc>
<publisher-name><![CDATA[The Pharmaceutical Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="">
<source><![CDATA[Cromatografía en la Química Clínica.: HPLC-Reactivos Merck]]></source>
<year>1988</year>
<page-range>3-16.</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4.</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quattrocchi]]></surname>
<given-names><![CDATA[OA]]></given-names>
</name>
<name>
<surname><![CDATA[Laba]]></surname>
<given-names><![CDATA[RF.]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Introducción a la HPLC.]]></article-title>
<source><![CDATA[Aplicación y práctica]]></source>
<year>1992</year>
<page-range>106-122, 284, 302-28.</page-range><publisher-loc><![CDATA[Buenos Aires ]]></publisher-loc>
<publisher-name><![CDATA[Ed. Artes Gráficas Farro SA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>5.</label><nlm-citation citation-type="">
<source><![CDATA[Validación de métodos analíticos: Sección Catalana de AEFI.]]></source>
<year>Sept</year>
<month>, </month>
<day>19</day>
<page-range>1-94.</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6.</label><nlm-citation citation-type="book">
<collab>United States Pharmacopoeial Convention</collab>
<source><![CDATA[USP 29. Validation of compendial]]></source>
<year>2006</year>
<month>.</month>
<edition>23 ed.</edition>
<page-range>1982-4.</page-range><publisher-loc><![CDATA[Rockville ]]></publisher-loc>
<publisher-name><![CDATA[Mack Printing]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7.</label><nlm-citation citation-type="">
<source><![CDATA[International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use, Validation of analytical procedures, ICH-Q2A]]></source>
<year>1995</year>
<publisher-loc><![CDATA[Geneva ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B8">
<label>8.</label><nlm-citation citation-type="">
<source><![CDATA[International Conference on Harmonization (ICH) of Technical Requirements for the Registration of Pharmaceuticals for Human Use, Validation of analytical procedures: Methodology, ICH-Q2B, Geneva, 1996.: ICH harmonized tripartite guideline. Methodology of validation of analytical method.]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sarrio]]></surname>
<given-names><![CDATA[RV]]></given-names>
</name>
<name>
<surname><![CDATA[Silvestre]]></surname>
<given-names><![CDATA[LJ.]]></given-names>
</name>
</person-group>
<source><![CDATA[Validation of Analytical Assays and Test Methods for the Pharmaceutical Laboratory.: The Regulatory Forum. Bioserch]]></source>
<year>1996</year>
<month>.</month>
</nlm-citation>
</ref>
<ref id="B10">
<label>10.</label><nlm-citation citation-type="">
<source><![CDATA[Guidance for Industry: Analytical Procedures and Methods Validation Chemistry, Manufacturing, and Controls Documentation]]></source>
<year>2001</year>
</nlm-citation>
</ref>
<ref id="B11">
<label>11.</label><nlm-citation citation-type="">
<source><![CDATA[Guidance for Industry.: Analytical Procedure and Methods Validation]]></source>
<year>Augu</year>
<month>st</month>
<day>, </day>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>