<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-0289</journal-id>
<journal-title><![CDATA[Revista Cubana de Hematología, Inmunología y Hemoterapia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Hematol Inmunol Hemoter]]></abbrev-journal-title>
<issn>0864-0289</issn>
<publisher>
<publisher-name><![CDATA[Centro Nacional de Información de Ciencias MédicasEditorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-02892001000100006</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Sensibilidad del tiempo parcial de tromboplastina activado a la deficiencia de factores VIII y IX Y a la heparina]]></article-title>
<article-title xml:lang="en"><![CDATA[Sensitivity of the activated partial thromboplastin time to the deficiency of factors VIII and IX and heparin]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Díaz Concepción]]></surname>
<given-names><![CDATA[Alina]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Almagro Vázquez]]></surname>
<given-names><![CDATA[Delfina]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Brito Martínez]]></surname>
<given-names><![CDATA[Alberto]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto de Hematología e Inmunología  ]]></institution>
<addr-line><![CDATA[Ciudad de La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2001</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2001</year>
</pub-date>
<volume>17</volume>
<numero>1</numero>
<fpage>41</fpage>
<lpage>48</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-02892001000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-02892001000100006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-02892001000100006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se reevaluó el rango de referencia del tiempo parcial de tromboplastina activada (TPTA). Se obtuvo un rango de referencia de 29 a 40 seg. con una media (<img width=13 height=15 id="_x0000_i1026" src=x.gif>) de 34,01 seg. Con nuestro sistema de reactivos se alcanzaron resultados aceptables en cuanto a la sensibilidad a diferentes niveles de actividad de los factores VIII y IX, se logró una alta correlación en ambos casos (r2 = 0,9842 y 0,9846, respectivamente) cuando se relacionó el TPTa con los diferentes niveles de actividad de los factores VIII y IX. Se obtuvo una respuesta lineal en el intervalo de actividad de heparina utilizado normalmente en la terapia (0,2 a 0,5 UI/mL) y se alcanó una buena respuesta a altas concentraciones de heparina (0,8 UI/mL), expresada por un valor finito del TPTa. Se corroboró la necesidad de alargar el tiempo de incubación con el activador a 10 min para mejorar la sensibilidad del ensayo a la heparina]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The reference range of the activated partial thromboplastin time (APTT) was reevaluated. A reference range from 29 to 40 seconds with a mean (<img border=0 width=13 height=15 id="_x0000_i1033" src=x.gif>) of 34.01 sec. was obtained. By using our system of reagents, acceptable results were obtained as regards the sensitivity to different levels of activity of factors VIII and IX. A high correlation was attained in both cases (r2 = 0.9842 and 0.9846, respectively) when the APTT was associated with the different levels of activity of factors VIII and IX. A linear response was obtained in the interval of heparin activity commonly used in therapy (0.2 to 0.5 UI/mL) and a good response was attained at high concentrations of heparin (0.8 UI/mL) expressed by a finite value of APTT. The need to extend the incubation time with the activator to 10 min. to improve the sensitivity of the test to heparin was corroborated]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[TIEMPO DE TROMBOPLASTINA PARCIAL]]></kwd>
<kwd lng="es"><![CDATA[FACTOR VIII]]></kwd>
<kwd lng="es"><![CDATA[FACTOR IX]]></kwd>
<kwd lng="es"><![CDATA[HEPARINA]]></kwd>
<kwd lng="en"><![CDATA[PARTIAL THROMBOPLASTIN TIME]]></kwd>
<kwd lng="en"><![CDATA[FACTOR VIII]]></kwd>
<kwd lng="en"><![CDATA[FACTOR IX]]></kwd>
<kwd lng="en"><![CDATA[HEPARIN]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p>Instituto de Hematología e Inmunología </p><h2>Sensibilidad del tiempo parcial  de tromboplastina activado a la deficiencia de factores VIII y IX Y a la heparina  </h2>    <p><i><a name="autor"></a><a href="#cargo">Lic. Alina Díaz Concepción, Dra.  Delfina Almagro Vázquez y Lic. Alberto Brito Martínez</a> </i></p><h4>RESUMEN</h4>    <p>Se  reevaluó el rango de referencia del tiempo parcial de tromboplastina activada  (TPTA). Se obtuvo un rango de referencia de 29 a 40 seg. con una media (<img src="x.gif" width="13" height="15">)  de 34,01 seg. Con nuestro sistema de reactivos se alcanzaron resultados aceptables  en cuanto a la sensibilidad a diferentes niveles de actividad de los factores  VIII y IX, se logró una alta correlación en ambos casos (r2 = 0,9842 y 0,9846,  respectivamente) cuando se relacionó el TPTa con los diferentes niveles de actividad  de los factores VIII y IX. Se obtuvo una respuesta lineal en el intervalo de actividad  de heparina utilizado normalmente en la terapia (0,2 a 0,5 UI/mL) y se alcanó  una buena respuesta a altas concentraciones de heparina (0,8 UI/mL), expresada  por un valor finito del TPTa. Se corroboró la necesidad de alargar el tiempo de  incubación con el activador a 10 min para mejorar la sensibilidad del ensayo a  la heparina. </p>    <p>DeCS: TIEMPO DE TROMBOPLASTINA PARCIAL; FACTOR VIII; FACTOR  IX; HEPARINA. </p>    <p>La determinación del tiempo de protrombina (TP) y del tiempo  parcial de tromboplastina activado (TPTA) se encuentran entre las pruebas de pesquisaje  más comúnmente realizadas en los laboratorios clínicos.<span class="superscript">1-3</span>  El TPTA se utiliza para el pesquisaje de las alteraciones del "sistema intrínseco"  de la coagulación, la deficiencia de factor VIII, de factor IX y de otras alteraciones  menos comunes.<span class="superscript">4,5</span> Cuando se modifica apropiadamente  el TPTA también se utiliza para estimar las concentraciones exactas de esos procoagulantes  en el plasma de pacientes y/o concentradas usados en la terapia.<span class="superscript">6</span>  Es la prueba más ampliamente usada para monitorear el nivel de anticoagulación  en pacientes sometidos a terapia con heparina<span class="superscript">7-10</span>  y para detectar inhibidores de la coagulación como el anticoagulante lúpico y  los inhibidores del factor VIII (FVIII) y del factor IX (FIX).<span class="superscript">11</span>  </p>    <p>Varios estudios han demostrado que los diferentes reactivos comerciales  y no comerciales usados para la realización del TPTA varían considerablemente  en su sensibilidad a la heparina (definida como el cambio en el tiempo de coagulación  para un incremento de concentración), particularmente para el FVIII y la heparina.<span class="superscript">12,13</span>  En un estudio cooperativo internacional, Poller y otros<span class="superscript">14</span>  demostraron que esas diferencias en sensibilidad afectaban la capacidad de los  reactivos para detectar alteraciones de la coagulación y que esto podría tener  consecuencias clínicas importantes. Se han emitido lineamientos para la realización  del TPTA en Estados Unidos por el Comité Nacional de Estándar para Laboratorio  Clínico<span class="superscript">15</span> y en Alemania por el Instituto Alemán  de Normalización.<span class="superscript">16</span> Por otra parte, en 1986 el  Comité Internacional de Estandarización en Hematología propuso los requerimientos  analíticos y de sensibilidad del TPTA y para la determinación del FVIII.<span class="superscript">17  </span></p>    <p>La expresión de los resultados varía también entre los diferentes  países y aún en diferentes laboratorios dentro de un mismo país.<span class="superscript">18  </span></p>    <p>De igual forma, los reactivos comerciales difieren ampliamente en  su sensibilidad a la heparina,<span class="superscript">19-21</span> de ahí que  los datos obtenidos con un sistema de reactivos no pueden extrapolarse a un sistema  de reactivos diferente. Por una parte los reactivos comerciales disponibles para  realizar el TPTA muestran una respuesta diferente a la heparina, y otro lado,  las heparinas usadas en la prevención y tratamiento de la trombosis reaccionan  de forma diferente hacia los mismos reactivos del TPTA.<span class="superscript">21</span>  </p>    <p>Se ha enfatizado la importancia de la estandarización de los variados aspectos  técnicos en la realización del TPTA. Cada laboratorio debe establecer su propio  rango de referencia para todas las pruebas con el empleo de una metodología idéntica  a la usada para los pacientes.<span class="superscript">22</span> En nuestro laboratorio  hace algunos años, se modificó la metodología utilizada para la realización del  TPTA, se determinó el nuevo rango de referencia y la sensibilidad a diferentes  niveles de deficiencia de los factores de la coagulación de la vía intrínseca.<span class="superscript">23  </span></p>    <p>En este trabajo se revisó el rango de referencia para el TPTA y  se determinó la sensibilidad de esta técnica para detectar diferentes niveles  de factores VIII y IX, así como diferentes concentraciones de heparina. </p><h4>M&Eacute;TODOS</h4><h4>Determinación  del rango de referencia del TPTA </h4>    ]]></body>
<body><![CDATA[<p>Se obtuvo sangre de 100 donantes del  Banco de Sangre entre 20-50 años de edad sin ingerir algún tipo de medicamentos  y sin evidencias de enfermedad. Se tomaron 9 mL de sangre para 1 mL de citrato  trisódico el 3,13 %, la sangre se centrifugó a 4 000 rev/min durante 15 min, el  plasma se decantó y se ensayó antes de las 2 horas de la toma de muestra. El TPTA  se realizó según el método de Proctor y Rapaport.<span class="superscript">24</span>  Se usó como activador caolín ligero (BDH) al 0,5 % en tampón imidazolsalino, pH  7,35, y como reactivo fosfolipídico, cefalina de cerebro humano producida en nuestro  laboratorio, según el método de Bell y Alton.<span class="superscript">25 </span></p><h4>Determinación  de la sensibilidad a los factores VIII y IX </h4>    <p>Se evaluó la sensibilidad  del TPTA a los diferentes niveles de deficiencia de los factores VIII y IX diluyendo  una mezcla de plasmas normales (plasma de 40 donantes del Banco de Sangre obtenidos  en las mismas condiciones anteriormente explicadas y guardadas en alícuotas a  –80 °C) con plasma deficiente de FVIII obtenido de un paciente hemofílico A con  menos del 1 % de actividad del FVIII y sin inhibidores, de forma tal que se obtuvieron  actividades teóricas desde 100 % hasta 10 % de FVIII. Los resultados se expresaron  como relación semilogarítmica entre el logaritmo de la actividad del FVIII y el  TPTA expresado en segundos. La sensibilidad al FIX se determinó de la misma forma,  solo que el plasma deficiente usado fue un plasma comercial deficiente en FIX  (Hemolab Cofactor IX BioMérieux). </p><h4>Determinación de la sensibilidad a la  heparina </h4>    <p>La sensibilidad a la heparina se realizó adicionando heparina  (Heparin Leo 5 000 UI/mL) a la mezcla de plasmas normales, de forma tal que se  obtuvieron actividades finales de 0,1; 0,2; 0,3; 0,4; 0,5; 0,6 y 0,8 UI/mL. A  cada una de estas muestras se les determinó el TPTA utilizando 2 sistemas de reactivos:  cefalina-caolín y ácido elágico (Hemostat APTT-EL). </p><h4>Influencia del tiempo  de activación</h4>    <p> Se realizó el TPTA a la mezcla de plas-mas normales y a  un plasma heparinizado, en una concentración de 0,1 UI/mL utilizan-do diferentes  tiempos de incubación con el activador (cefalina-caolín) desde 1 a 14 minutos.  </p>    <p>Todas las determinaciones se reali-zaron en un coagulómetro Amelung modelo  KC-10 por duplicado y se repitieron 5 veces. </p>    <p>Los cálculos estadísticos  se realizaron usando el paquete estadístico MICROSTA.</p><h4> RESULTADOS</h4>    <p>Los  resultados obtenidos para el TPTA en el grupo de100 donantes fueron X = 34,01  seg, con una desviación estándar de 2,83 seg. Se estableció un rango de referencia  de 24-40 seg (X ± 2DS) o de 0,85-1, <span class="superscript">17</span>, expresados  como la relación entre el tiempo de coagulación de la muestra y el obtenido con  la mezcla de plasmas normales. </p>    <p>Las figuras 1 y 2 muestran las curvas de  sensibilidad del TPTA a los factores VIII y IX, respectivamente, expresados como  la relación semilogarítmica entre el TPTA (seg) y el logaritmo de la actividad  del FVIII ó FIX (%). Los coeficientes (r2) fueron excelentes en ambos casos (0,9909  y 0,9807, respectivamente). La sensibilidad del TPTA es casi la misma cuando varían  los niveles de actividad de FVIII y FIX en el plasma. </p>    <p>&nbsp;</p>    <p align="center"><a href="/img/revistas/hih/v17n1/f0106101.jpg"><img src="/img/revistas/hih/v17n1/f0106101.jpg" width="267" height="125" border="0"></a></p>    
]]></body>
<body><![CDATA[<p align="center">Fig.  1. Recta de regresión que relaciona el tiempo parcial de tromboplastina activada  (TPTA) y la concentración de factor VIII. </p>    <p align="center">&nbsp;</p>    <p align="center"><a href="/img/revistas/hih/v17n1/f0206101.jpg"><img src="/img/revistas/hih/v17n1/f0206101.jpg" width="330" height="115" border="0"></a></p>    
<p align="center">Fig.  2. Recta de regresión que relaciona el tiempo parcial de tromboplastina activada  (TPTA) y la concentración de factor IX. </p>    <p>Las curvas de sensibilidad a la  heparina (fig. 3) muestran que la linealidad y la pendiente fueron buenas en los  2 sistemas investigados. Los coeficientes de correlación (r2) fueron de 0,9842  y 0,9846, respectivamente y p altamente significativa (p < 0,0001) en ambos sistemas.  </p>    <p>&nbsp;</p>    <p align="center"><a href="/img/revistas/hih/v17n1/f0306101.jpg"><img src="/img/revistas/hih/v17n1/f0306101.jpg" width="224" height="256" border="0"></a></p>    
<p align="center">Fig.  3. Rectas de regresión para los valores del TPTA obtenidos con diferentes concentraciones  de heparina. A) activador caolín cefalina; B) activador ácido elágico (Hemostat  a PTT-EL). </p>    <p>La respuesta a bajas concentraciones de heparina (0,2 UI/mL)  fue adecuada para ambos activadores, ya que se obtuvo una relación plasma heparinizado/plasma  no heparinizado superior al límite máximo normal (1, 17 y 1, 18) respectivamente,  aunque no ocurrió así a la concentración de heparina de 0,1 UI/mL. Con el activador  cefalina-caolín se observó una mayor sensibilidad a la heparina, expresada por  relaciones más altas plasma heparinizado/plasma no heparinizado (tabla). </p>    <p>&nbsp;</p>    ]]></body>
<body><![CDATA[<p align="center">Tabla.  Sensibilidad a la heparina. Relación entre el tiempo parcial de tromboplastina  activado del plasma normal y del plasma con heparina con los tipos de activadores  </p><table width="75%" border="1" align="center"> <tr> <td>Concentración de</td><td>      <div align="center">Relación PN/PH </div></td><td>     <div align="center">Relación  PN/PH</div></td></tr> <tr> <td>heparina UI/mL) </td><td>     <div align="center">caolín-cefalina  </div></td><td>     <div align="center">Hemostata PTT-EL</div></td></tr> <tr> <td>0,1</td><td>      <div align="center">1,14 </div></td><td>     <div align="center">1,11</div></td></tr>  <tr> <td>0,2 </td><td>     <div align="center">1,47 </div></td><td>     <div align="center">1,39</div></td></tr>  <tr> <td>0,3 </td><td>     <div align="center">1,98</div></td><td>     ]]></body>
<body><![CDATA[<div align="center">1,84</div></td></tr>  <tr> <td>0,4 </td><td>     <div align="center">2,44 </div></td><td>     <div align="center">2,14</div></td></tr>  <tr> <td>0,5 </td><td>     <div align="center">2,85 </div></td><td>     <div align="center">2,65  </div></td></tr> <tr> <td>0,6</td><td>     <div align="center">3,49 </div></td><td>      <div align="center">3,16</div></td></tr> <tr> <td>0,8</td><td>     <div align="center">4,50</div></td><td>      <div align="center">3,79 </div></td></tr> <tr> <td>Rango normal TPTA</td><td>      <div align="center">0,85 -1,17</div></td><td>     ]]></body>
<body><![CDATA[<div align="center">0,85 -1,18</div></td></tr>  </table>    <p align="center"> PN: plasma normal; PH: plasma con heparina; TPTA: tiempo  parcial de tromboplastina activado.</p>    <p>La influencia del tiempo de incubación  con el caolín en la sensibilidad a la heparina se demuestra en la figura 4. Las  diferencias entre plasma heparinizado y no heparinizado aumentan después de 5  minutos de incubación. </p>    <p align="center"><a href="/img/revistas/hih/v17n1/f0406101.jpg"><img src="/img/revistas/hih/v17n1/f0406101.jpg" width="306" height="150" border="0"></a></p>    
<p align="center">Fig.  4. Efecto del tiempo de activación con caolín en la sensibilidad del TPTA a la  heparina. </p><h4>DISCUSI&Oacute;N</h4>    <p>Es conocida la importancia de la estandarización  de los diferentes aspectos técnicos en la realización del TPTA. En nuestro laboratorio,  hace algunos años se estableció la metodología actualmente utilizada para la realización  del TPTA y se estableció un rango de referencia de 31 a 45 seg para el método  automático, y de 32 a 46 seg para el método manual, sin embargo, posteriormente  observamos que pacientes con TPTA superiores a 40 seg tienen una deficiencia muy  ligera de factor VIII ó IX, por lo que decidimos revisar el rango de referencia  anteriormente establecido. La determinación del TPTA en 100 donantes de sangre  resultó en un rango de referencia de 19-40 seg (<img src="x.gif" width="13" height="15">  ± 2DS) y <img src="x.gif" width="13" height="15"> = 34,01 seg. </p>    <p>Al estudiar  la sensibilidad del TPTA para detectar variados niveles de referencia de factores  VIII y IX (figs.1 y 2), se obtuvo que para un valor teórico de actividad del FVIII  y FIX de 50 %, el TPTA obtenido fue de 40,8 y 40,1 seg, se obtuvieron valores  superiores de TPTA para niveles de actividad de FVIII y FIX inferiores a 50 %  (límite inferior del nivel normal), lo que está en correspondencia con el rango  de referencia obtenido para el TPTA. </p>    <p>Nuestro sistema de reactivos demostró  una buena sensibilidad a los factores VIII y IX con altos coeficientes de correlación  (0,9909 y 0,9807, respectivamente). Se comprobó que la sensibilidad del TPTA es  casi la misma cuando varían los niveles de FVIII y FIX. En 1986, el panel de TPTA  del Comité Internacional de Estandarización en Hematología propuso una relación  entre el logaritmo de la actividad del FVIII y TPTA, expresada por la ecuación  de la línea de regresión y = 100-32X,17 dado que el límite de tolerancia para  el TPTA (Y) es ± 10 % del TPTA realmente obtenido. Nuestro sistema se encuentra  dentro de los límites de tolerancia establecidos por este panel. </p>    <p>Los resultados  obtenidos indican que nuestro sistema tiene buena respuesta a una actividad de  heparina alta (0,8 U/mL) y que se obtiene una respuesta lineal en el interva-lo  de actividad de la heparina utilizado normalmente en la terapia (0,2-0,5 UI/mL).  Los coeficientes de correlación que utilizan como activador el caolín (r2 = 0,9842),  así como el ácido elágico (r2 = 0,9846), fueron excelentes (fig. 3). Cuando se  empleó este último, la sensibilidad a la heparina expresada como la relación plasma  heparinizado/plasma no heparinizado (tabla 1), fue inferior a la obtenida cuando  se usó el caolín como activador, lo que está acorde con lo repor-tado en la literatura.<span class="superscript">26</span>  </p>    <p>Con ambos tipos de activadores se pudieron detectar altas actividades de  heparina (0,8 UI/mL). Cerneca y otros<span class="superscript">27</span> ensayaron  la sensibilidad a la heparina de diferentes sistemas comerciales con diferentes  métodos de detección del coágulo. Se obtuvo un valor finito del TPTA a altas concentraciones  de heparina (0,8 UI/mL) solo con el sistema Stago-Sta, lo cual se relacionó con  el método de detección del coágulo utilizado (electromecánico). Estos autores  plantearon que parece probable que la optimización del método de detección del  coágulo hace posible medir períodos más largos de formación de fibrina de forma  más exacta que usando otros sistemas. </p>    ]]></body>
<body><![CDATA[<p>El tiempo de activación es importante  en la sensibilidad del TPTA a la heparina. Nuestros resultados demostraron que  con tiempos de incubación del activador con el plasma heparinizado mayores de  5 minutos, se obtienen resultados superiores. Ya otros autores han señalado que  en interés de la reproductibilidad del método, es preferible usar 10 minutos como  tiempo de incubación, para garantizar una activación completa.<span class="superscript">28  </span></p>    <p>Una solución a la carencia de estandarización del TPTA existente  hasta el momento es la evaluación de la sensibilidad del sistema utilizado por  medio de ensayos in vitro, seleccionando reactivos con suficiente sensibilidad  para los requerimientos de una situación clínica dada. Con nuestro sistema se  obtuvieron resultados aceptables en cuanto a la sensibilidad del TPTA a los diferentes  niveles de deficiencia de factores VIII y IX. Por otra parte, se obtuvo una respuesta  adecuada a bajas concentraciones de heparina (0,2 UI/mL), así como un valor finito  de TPTA a altas concentraciones de heparina. Se estableció un tiempo óptimo de  incubación con el activador superior de 10 minutos, con el objetivo de lograr  una activación más completa y aumentar la sensibilidad de la prueba. </p><h4>SUMMARY</h4>    <p>The  reference range of the activated partial thromboplastin time (APTT) was reevaluated.  A reference range from 29 to 40 seconds with a mean (<img src="x.gif" width="13" height="15">)  of 34.01 sec. was obtained. By using our system of reagents, acceptable results  were obtained as regards the sensitivity to different levels of activity of factors  VIII and IX. A high correlation was attained in both cases (r2 = 0.9842 and 0.9846,  respectively) when the APTT was associated with the different levels of activity  of factors VIII and IX. A linear response was obtained in the interval of heparin  activity commonly used in therapy (0.2 to 0.5 UI/mL) and a good response was attained  at high concentrations of heparin (0.8 UI/mL) expressed by a finite value of APTT.  The need to extend the incubation time with the activator to 10 min. to improve  the sensitivity of the test to heparin was corroborated. </p>    <p>Subject headings:  PARTIAL THROMBOPLASTIN TIME; FACTOR VIII; FACTOR IX; HEPARIN. </p><h4> REFERENCIAS  BIBLIOGR&Aacute;FICAS</h4>    <!-- ref --><P>1. Quick AJ, Stanley-Brown M, Bancrott FW. A study  of the coagulation defect in hemophilia and in jaundice. Am J Med Sci 1935;190:501-11.  <!-- ref --><P> 2. Poller L, Thomson JM, Taberner DA. Use of the activated partial thromboplastin  time for monitoring heparin therapy: problems and possible solutions. Res Clin  Lab 1989;19:363-70.<!-- ref --><P> 3. Suchman AL, Griner FF. Diagnostic uses of the partial  thromboplastin time and prothrombin time. Ann Intern Med 1985;104:810-6. <P>  4. Brinkhous KM, Dombrose FA. Partial thromboplastin time in handbook series.  En: Schmidt RM, ed Hematology. Boca Raton: CRC Press, 1980;vol 3:216-21.</P>    <!-- ref --><P>  5. Barna L, Triplett DA. Use of activated thromboplastin time for the diagnosis  of congenital coagulation disorders: problems and possible solutions. Ric Clin  Lab 1989;19:345-54. <!-- ref --><P> 6. Bowie EJW, Thomson JH, Didishem P, Owen CA. Laboratory  manual of hemostasis. Philadelphia: WB Saunders, 1971:111-3.<!-- ref --><P> 7. Brandt  JT, Triplett DA. Laboratory monitoring of heparin. Effect of reagents and instrument  on the activated partial thromboplastin time. Am J Clin Pathol 1981;76:530-7.  <P> 8. Van der Besselaar AMPH, Meeuwisse-Braun J, Jansen-Guiter R. Monitoring  heparin therapy by the activated partial thromboplastin time. The effect of preanalytical  conditions. Thromb Haemost 1987;57:226-31.</P>    <!-- ref --><P> 9. Calvin BT, Barrowcliffe TW,  The British Society for Haematology. Guidelines on the use and monitoring of heparin  1992 Second Revision. J Clin Pathol 1993;46:97-103. <!-- ref --><P> 10. Stevenson KJ,  Eaeston AC, Thomson JM, Poller L. Lipid class composition and heparin sensitivity  in the activated thromboplastin time. Thromb Haemost 1983;50:601-3. <!-- ref --><P> 11.  Kelsey PR, Stevenson KJ, Poller L. Lupus anticoagulant and phosphatidyl serine:  demostration of their inter-relationship and of a possible diagnostic test. Br  J Haematol 1984;56:671-6. <!-- ref --><P> 12. Sibley CS, Singer JW, Wood RT. Comparison  of activated partial thromboplastin reagents. Am J Clin Pathol 1983;59:581-6.  <!-- ref --><P> 13. Hoffman JML, Meulendijk PN. Comparison of reagents for determining  the activated partial thromboplastin time. Thromb Haemost 1978;39:640-5. <!-- ref --><P>  14. Poller L, Thromson JM, Palmer MK. Measuring partial thromboplastin time. An  international collaborative study. Lancet 1976;1:842-6. <!-- ref --><P> 15. National Commitee  for Clinical Laboratory Standars (NCCLS). Activated partial thromboplastin time  test (APTT). Tentative Guideline NCCLS document H 29-T Villanova, 1992. <!-- ref --><P>  16. DIN Deutsches Institut für Normung: Haemosta Serologic: Normen. Berlin: Beuth  Verlag, 1995. <!-- ref --><P> 17. Koepke JA. Partial thromboplastin time test. Proposed  performance guidelines ICSH Panel on the PTT. Thromb Haemost 1986;55:143-4. <!-- ref --><P>  18. Dati F. Quality management and standarization programs in Haemostaseology  JIFCC 1996;8:111-6. <!-- ref --><P> 19. Soloway HB, Bellineau RR, Grayson JWJr, Butler  JJ. The in vitro effect of heparin on the partial thromboplastin time. Am J Clin  Pathol 1972;58:405-7. <!-- ref --><P> 20. Shapiro GA, Huntzinger SW, Wilson JE. Variations  among commercial activated partial thromboplastin time reagents in response to  heparin. Am J Clin Pathol 1972;67:477-80.<!-- ref --><P> 21. Bjorsson TR, Nash PV. Variability  in heparin sensitivity of APTT reagent. Am J Clin Pathol 1986;86:199-204. <!-- ref --><P>  22. Peake I, Seligsohn U, Gitel S, Kitchen S, Zevelix A. The laboratory diagnosis  of haemophilia: recommendations by the Laboratory activities Committie of the  World Federation of Hemophilia. Haemophilia 1995;1:159-64. <!-- ref --><P> 23. Rubio R,  Almagro D, González A, Mesa J, Fonseca C. Algunas consideraciones actuales sobre  el tiempo parcial de tromboplastina activado. Rev Cubana Hematol Inmunol Hemoter  1986;2:235-42.<!-- ref --><P> 24. Proctor RR, Rapaport SI. The partial thromboplastin  time with kaolín. Am J Clin Pathol 1961;36:212. <!-- ref --><P> 25. Bell WN, Alton HG.  A brain extract as a substitute for platelet suspension in the thromboplastin  generation test. Nature 1954;174:880-1.<!-- ref --><P> 26. Barrowcliffe TW, Gray E. Studies  of phospholipid reagents used in coagulation II: factors influencing their sensitivity  to heparin. Thromb Haemost 1981;46:634-7. <!-- ref --><P> 27. Cerneca F, Bruno G, Simeone  R, Bet N, Bertolessi M, Oliviere ML, et al. Activated partial thromboplastin time:  sensivity to heparin and factor VIII deficiency. Transfus Sangue 1997;42:160-5.  <!-- ref --><P> 28. Barrowcliffe TW, Gray E. Studies of phospholipid reagents used in  coagulation I: some general properties and their sensivity to factor VIII. Thromb  Haemost 1981;46:629-33. <p>Recibido: 20 de diciembre de 1999. Aprobado 24  de diciembre de 1999.     <br> <a name="cargo"></a><a href="#autor">Lic. Alina Díaz  Concepción. Instituto de Hematología e Inmunología. Apartado 8070, CP 10800, Ciudad  de La Habana, Cuba. Teléf.: (537)578268. Fax (537) 338979.</a><a href="mailto%20e-mail:ihidir@hemato.sld.cu%20">  e-mail:ihidir@hemato.sld.cu </a> </p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quick]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Stanley-Brown]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bancrott]]></surname>
<given-names><![CDATA[FW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A study of the coagulation defect in hemophilia and in jaundice]]></article-title>
<source><![CDATA[Am J Med Sci]]></source>
<year>1935</year>
<volume>190</volume>
<page-range>501-11</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Poller]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Thomson]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Taberner]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of the activated partial thromboplastin time for monitoring heparin therapy: problems and possible solutions]]></article-title>
<source><![CDATA[Res Clin Lab]]></source>
<year>1989</year>
<volume>19</volume>
<page-range>363-70</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Suchman]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Griner]]></surname>
<given-names><![CDATA[FF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diagnostic uses of the partial thromboplastin time and prothrombin time]]></article-title>
<source><![CDATA[Ann Intern Med]]></source>
<year>1985</year>
<volume>104</volume>
<page-range>810-6</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brinkhous]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Dombrose]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Partial thromboplastin time in handbook series]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Schmidt]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
</person-group>
<source><![CDATA[Hematology]]></source>
<year>1980</year>
<page-range>216-21</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barna]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Triplett]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Use of activated thromboplastin time for the diagnosis of congenital coagulation disorders: problems and possible solutions]]></article-title>
<source><![CDATA[Ric Clin Lab]]></source>
<year>1989</year>
<volume>19</volume>
<page-range>345-54</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bowie]]></surname>
<given-names><![CDATA[EJW]]></given-names>
</name>
<name>
<surname><![CDATA[Thomson]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Didishem]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Owen]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
</person-group>
<source><![CDATA[Laboratory manual of hemostasis]]></source>
<year>1971</year>
<page-range>111-3</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brandt]]></surname>
<given-names><![CDATA[JT]]></given-names>
</name>
<name>
<surname><![CDATA[Triplett]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Laboratory monitoring of heparin: Effect of reagents and instrument on the activated partial thromboplastin time]]></article-title>
<source><![CDATA[Am J Clin Pathol]]></source>
<year>1981</year>
<volume>76</volume>
<page-range>530-7</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Besselaar]]></surname>
<given-names><![CDATA[AMPH]]></given-names>
</name>
<name>
<surname><![CDATA[Meeuwisse-Braun]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jansen-Guiter]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Monitoring heparin therapy by the activated partial thromboplastin time: The effect of preanalytical conditions]]></article-title>
<source><![CDATA[Thromb Haemost]]></source>
<year>1987</year>
<volume>57</volume>
<page-range>226-31</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Calvin]]></surname>
<given-names><![CDATA[BT]]></given-names>
</name>
<name>
<surname><![CDATA[Barrowcliffe]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The British Society for Haematology. Guidelines on the use and monitoring of heparin 1992 Second Revision]]></article-title>
<source><![CDATA[J Clin Pathol]]></source>
<year>1993</year>
<volume>46</volume>
<page-range>97-103</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stevenson]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Eaeston]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Thomson]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Poller]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lipid class composition and heparin sensitivity in the activated thromboplastin time]]></article-title>
<source><![CDATA[Thromb Haemost]]></source>
<year>1983</year>
<volume>50</volume>
<page-range>601-3</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kelsey]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
<name>
<surname><![CDATA[Stevenson]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Poller]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Lupus anticoagulant and phosphatidyl serine: demostration of their inter-relationship and of a possible diagnostic test]]></article-title>
<source><![CDATA[Br J Haematol]]></source>
<year>1984</year>
<volume>56</volume>
<page-range>671-6</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sibley]]></surname>
<given-names><![CDATA[CS]]></given-names>
</name>
<name>
<surname><![CDATA[Singer]]></surname>
<given-names><![CDATA[JW]]></given-names>
</name>
<name>
<surname><![CDATA[Wood]]></surname>
<given-names><![CDATA[RT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of activated partial thromboplastin reagents]]></article-title>
<source><![CDATA[Am J Clin Pathol]]></source>
<year>1983</year>
<volume>59</volume>
<page-range>581-6</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hoffman]]></surname>
<given-names><![CDATA[JML]]></given-names>
</name>
<name>
<surname><![CDATA[Meulendijk]]></surname>
<given-names><![CDATA[PN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of reagents for determining the activated partial thromboplastin time]]></article-title>
<source><![CDATA[Thromb Haemost]]></source>
<year>1978</year>
<volume>39</volume>
<page-range>640-5</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Poller]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Thromson]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Palmer]]></surname>
<given-names><![CDATA[MK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measuring partial thromboplastin time: An international collaborative study]]></article-title>
<source><![CDATA[Lancet]]></source>
<year>1976</year>
<volume>1</volume>
<page-range>842-6</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="">
<collab>National Commitee for Clinical Laboratory Standars (NCCLS)</collab>
<source><![CDATA[Activated partial thromboplastin time test (APTT)]]></source>
<year>1992</year>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="">
<collab>DIN Deutsches Institut für Normung</collab>
<source><![CDATA[Haemosta Serologic: Normen]]></source>
<year>1995</year>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koepke]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Partial thromboplastin time test: Proposed performance guidelines ICSH Panel on the PTT]]></article-title>
<source><![CDATA[Thromb Haemost]]></source>
<year>1986</year>
<volume>55</volume>
<page-range>143-4</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dati]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quality management and standarization programs in Haemostaseology]]></article-title>
<source><![CDATA[JIFCC]]></source>
<year>1996</year>
<volume>8</volume>
<page-range>111-6</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Soloway]]></surname>
<given-names><![CDATA[HB]]></given-names>
</name>
<name>
<surname><![CDATA[Bellineau]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
<name>
<surname><![CDATA[Grayson]]></surname>
<given-names><![CDATA[JWJr]]></given-names>
</name>
<name>
<surname><![CDATA[Butler]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The in vitro effect of heparin on the partial thromboplastin time]]></article-title>
<source><![CDATA[Am J Clin Pathol]]></source>
<year>1972</year>
<volume>58</volume>
<page-range>405-7</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shapiro]]></surname>
<given-names><![CDATA[GA]]></given-names>
</name>
<name>
<surname><![CDATA[Huntzinger]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
<name>
<surname><![CDATA[Wilson]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Variations among commercial activated partial thromboplastin time reagents in response to heparin]]></article-title>
<source><![CDATA[Am J Clin Pathol]]></source>
<year>1972</year>
<volume>67</volume>
<page-range>477-80</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bjorsson]]></surname>
<given-names><![CDATA[TR]]></given-names>
</name>
<name>
<surname><![CDATA[Nash]]></surname>
<given-names><![CDATA[PV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Variability in heparin sensitivity of APTT reagent]]></article-title>
<source><![CDATA[Am J Clin Pathol]]></source>
<year>1986</year>
<volume>86</volume>
<page-range>199-204</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Peake]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Seligsohn]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Gitel]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kitchen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Zevelix]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The laboratory diagnosis of haemophilia: recommendations by the Laboratory activities Committie of the World Federation of Hemophilia]]></article-title>
<source><![CDATA[Haemophilia]]></source>
<year>1995</year>
<volume>1</volume>
<page-range>159-64</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rubio]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Almagro]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mesa]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Fonseca]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Algunas consideraciones actuales sobre el tiempo parcial de tromboplastina activado]]></article-title>
<source><![CDATA[Rev Cubana Hematol Inmunol Hemoter]]></source>
<year>1986</year>
<volume>2</volume>
<page-range>235-42</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Proctor]]></surname>
<given-names><![CDATA[RR]]></given-names>
</name>
<name>
<surname><![CDATA[Rapaport]]></surname>
<given-names><![CDATA[SI]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The partial thromboplastin time with kaolín]]></article-title>
<source><![CDATA[Am J Clin Pathol]]></source>
<year>1961</year>
<volume>36</volume>
<page-range>212</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bell]]></surname>
<given-names><![CDATA[WN]]></given-names>
</name>
<name>
<surname><![CDATA[Alton]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A brain extract as a substitute for platelet suspension in the thromboplastin generation test]]></article-title>
<source><![CDATA[Nature]]></source>
<year>1954</year>
<volume>174</volume>
<page-range>880-1</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barrowcliffe]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
<name>
<surname><![CDATA[Gray]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Studies of phospholipid reagents used in coagulation II: factors influencing their sensitivity to heparin]]></article-title>
<source><![CDATA[Thromb Haemost]]></source>
<year>1981</year>
<volume>46</volume>
<page-range>634-7</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cerneca]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Bruno]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Simeone]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Bet]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Bertolessi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Oliviere]]></surname>
<given-names><![CDATA[ML]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Activated partial thromboplastin time: sensivity to heparin and factor VIII deficiency]]></article-title>
<source><![CDATA[Transfus Sangue]]></source>
<year>1997</year>
<volume>42</volume>
<page-range>160-5</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barrowcliffe]]></surname>
<given-names><![CDATA[TW]]></given-names>
</name>
<name>
<surname><![CDATA[Gray]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Studies of phospholipid reagents used in coagulation I: some general properties and their sensivity to factor VIII]]></article-title>
<source><![CDATA[Thromb Haemost]]></source>
<year>1981</year>
<volume>46</volume>
<page-range>629-33</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
