<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-0300</journal-id>
<journal-title><![CDATA[Revista Cubana de Investigaciones Biomédicas]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Invest Bioméd]]></abbrev-journal-title>
<issn>0864-0300</issn>
<publisher>
<publisher-name><![CDATA[ECIMED]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-03001996000200007</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Métodos para el análisis cuantitativo del electromiograma]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández Toranzo]]></surname>
<given-names><![CDATA[Rebeca]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Hospital Militar Dr. Carlos J Finlay  ]]></institution>
<addr-line><![CDATA[Ciudad de La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>1996</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>1996</year>
</pub-date>
<volume>15</volume>
<numero>2</numero>
<fpage>0</fpage>
<lpage>0</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-03001996000200007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-03001996000200007&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-03001996000200007&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Los métodos cuantitativos automáticos o semiautomáticos aplicados a la electromiografía constituyen sin lugar a dudas un paso de avance en el desarrollo científico de esta especialidad y en general, en sus aplicaciones al diagnóstico clínico. En el presente trabajo hacemos una revisión al respecto, señalando sus principales ventajas y desventajas, así como sus aplicaciones clínicas.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The automated or semiautomated cuantitative methods applied to electromyography are undoubtedly a step of advance in the scientific development of this speciality and, in general, in its applications to clinical diagnosis. In the present paper we make a review on this regard, expressing their advantages and disadvantages, as well as their clinical applications.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[ELECTROMIOGRAFIA]]></kwd>
<kwd lng="es"><![CDATA[AUTOMATIZACION]]></kwd>
<kwd lng="en"><![CDATA[ELECTROMYOGRAPHY]]></kwd>
<kwd lng="en"><![CDATA[AUTOMATION]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <HTML>   <HEAD>      <META HTTP-EQUIV="Content-Type" CONTENT="text/html; charset=iso-8859-1">      <META NAME="Generator" CONTENT="Microsoft Word 97">      <META NAME="Template" CONTENT="D:\MICROSOFT OFFICE\OFFICE\html.dot">      <META NAME="GENERATOR" CONTENT="Mozilla/4.05 [en] (Win95; I) [Netscape]">      <META NAME="Author" CONTENT="Juana Perez">      <TITLE>M&eacute;todos para el an&aacute;lisis cuantitativo del electromiograma</TITLE>   <LINK rel="STYLESHEET" href="../ibistyle.css" type="text/css">   </HEAD> <H3> T&eacute;cnicas</H3>Hospital Militar "Dr. Carlos J. Finlay" <H2> M&eacute;todos  para el an&aacute;lisis cuantitativo del electromiograma</H2><I>Dra. Rebeca Hern&aacute;ndez  Toranzo</I> <H4> RESUMEN</H4>Los m&eacute;todos cuantitativos autom&aacute;ticos  o semiautom&aacute;ticos aplicados a la electromiograf&iacute;a constituyen sin  lugar a dudas un paso de avance en el desarrollo cient&iacute;fico de esta especialidad  y en general, en sus aplicaciones al diagn&oacute;stico cl&iacute;nico. En el  presente trabajo hacemos una revisi&oacute;n al respecto, se&ntilde;alando sus  principales ventajas y desventajas, as&iacute; como sus aplicaciones cl&iacute;nicas.      <P><I>Palabras clave</I>: ELECTROMIOGRAFIA/m&eacute;todos; AUTOMATIZACION. INTRODUCCION      <P>La electromiograf&iacute;a o electromiograma (EMG) propiamente dicho consiste  en el registro de las variaciones de voltaje que se producen en las fibras musculares  como expresi&oacute;n de la despolarizaci&oacute;n de sus membranas durante la  contracci&oacute;n espont&aacute;nea o voluntaria.     <P>Para el registro del EMG  convencional se pueden utilizar electrodos de aguja que se insertan en los m&uacute;sculos  que se van explorar o electrodos de superficie que se colocan sobre la piel que  los recubre. En sentido general, los registros obtenidos con estos &uacute;ltimos  no se han utilizado con prop&oacute;sitos cl&iacute;nicos, debido a la dificultad  que presentan ellos en la identificaci&oacute;n de los potenciales individuales.  Adem&aacute;s de los electrodos se necesita un osciloscopio y la observaci&oacute;n  de un especialista , quien realizar&aacute; un an&aacute;lisis de la actividad  registrada, basado fundamentalmente en sus conocimientos y experiencia.     <P>El  examen electromiogr&aacute;fico con agujas de cada m&uacute;sculo consta de 3  pasos b&aacute;sicos: <OL>     <LI> La observaci&oacute;n de la actividad posinsercional  y espont&aacute;nea durante el reposo.</LI>    <LI> El an&aacute;lisis de los potenciales  de unidad motora individuales durante la contracci&oacute;n muscular ligera.</LI>    <LI>  El an&aacute;lisis del registro de la actividad contr&aacute;ctil durante el m&aacute;ximo  esfuerzo voluntario.<SUP>1</SUP></LI>    </OL>La contracci&oacute;n de cada fibra  muscular individual genera un potencial de acci&oacute;n. La suma de los potenciales  de todas las fibras que componen una unidad motora (UM) constituye el potencial  de unidad motora (PUM).<SUP>1</SUP> Las t&eacute;cnicas de EMG convencional con  agujas conc&eacute;ntricas no registran potenciales de acci&oacute;n de una sola  fibra muscular, sino aquellos generados por la despolarizaci&oacute;n simult&aacute;nea  de muchas fibras musculares cercanas al electrodo en una o varias unidades motoras  (UMs).<SUP>1</SUP> Existen agujas especiales (fibra simple) para el registro del  potencial de acci&oacute;n de una sola fibra muscular.     <P>Desde el inicio, en  la utilizaci&oacute;n del EMG<SUP>2</SUP>, los PUMs registrados con agujas fueron  descritos cualitativamente, teniendo en cuenta para ello ciertas caracter&iacute;sticas  como son: la amplitud, la duraci&oacute;n y el n&uacute;mero de fases. Con la  ayuda de la computaci&oacute;n es posible medir &eacute;stos y otros par&aacute;metros  que son de utilidad para la evaluaci&oacute;n del estado funcional del aparato  neuromuscular. Entre ellas se pueden incluir el &aacute;rea bajo la curva rectificada,  el n&uacute;mero de <I>turns</I> y la frecuencia de descarga.<SUP>3</SUP>     ]]></body>
<body><![CDATA[<P>El  uso de m&eacute;todos cuantitativos autom&aacute;ticos o semiautom&aacute;ticos  aplicados al EMG ahorra tiempo de trabajo, hace el procedimiento menos engorroso  para la persona que lo ejecuta y de cierta forma posibilita el aporte de informaci&oacute;n  adicional imposible de obtener con los estudios de rutina.<SUP>4</SUP>     <P>No obstante  las ventajas que a primera vista ofrece este tipo de an&aacute;lisis, existen  algunas limitaciones en cuanto a su uso. Entre ellas podemos mencionar la variabilidad  de la se&ntilde;al electromiogr&aacute;fica a diferentes niveles de contracci&oacute;n,  la dependencia de la se&ntilde;al obtenida de la posici&oacute;n de la aguja respecto  a la placa motora, la sensibilidad de las diferentes caracter&iacute;sticas de  los PUMs para los diferentes tipos de enfermedades neuromusculares y aun en los  diferentes estadios de una misma enfermedad, as&iacute; como la variabilidad del  patr&oacute;n de contracci&oacute;n de sujeto a sujeto, por edad y por sexo.<SUP>4-6</SUP>      <P>Se han desarrollado en diversas partes del mundo diferentes m&eacute;todos  cuantitativos tanto para el an&aacute;lisis de los PUMs individuales como del  patr&oacute;n de interferencia.     <P>ANALISIS DE LOS PUMS INDIVIDUALES     <P>Durante  el desarrollo de esta rama se han empleado m&eacute;todos manuales, semiautom&aacute;ticos  o autom&aacute;ticos, de acuerdo con las tecnolog&iacute;as existentes en cada  momento. El m&eacute;todo de Buchtal<SUP>7</SUP> es un m&eacute;todo manual donde  los PUMs se graban en un papel o fotograf&iacute;a sobre el cual se realizan las  mediciones, lo que consume mucho tiempo de trabajo. Se basa en la apreciaci&oacute;n  del especialista sobre la replicabilidad de las formas de los PUMs que rebasen  cierto umbral de amplitud. Este m&eacute;todo fue perfeccionado por otros investigadores  como <I>Czekajewski</I><SUP> 8</SUP> y <I>Nissen-Petersen.</I><SUP>9</SUP> Se  debe se&ntilde;alar que este m&eacute;todo y la metodolog&iacute;a empleada para  la medici&oacute;n de los PUMs han sido la base de otros muchos m&eacute;todos  m&aacute;s avanzados y cercanos a nuestros d&iacute;as tales como los de Bergmans,<SUP>10,11</SUP>  <I>Lee </I>y <I>White</I>,<SUP>12</SUP> <I>Tanzi</I>,<SUP>13</SUP> <I>Stalberg</I>  y <I>Antoni</I>,<SUP>14</SUP> <I>Andreassen</I>,<SUP>15</SUP> <I>Coatrieux.</I><SUP>16,17</SUP>  y otros.     <P>La mayor&iacute;a de estos m&eacute;todos han sido aplicados en sujetos  sanos, en enfermos con miositis, polirradiculopat&iacute;as y con enfermedad de  la motoneurona.<SUP>4</SUP>     <P>Se han desarrollado otros m&eacute;todos que miden  autom&aacute;ticamente las propiedades de todos los potenciales que exceden un  cierto nivel de umbral. Estos tienden a ser r&aacute;pidos y eficientes, ya que  eliminan las complejidades que se requieren en el procesamiento de la se&ntilde;al  para la identificaci&oacute;n y clasificaci&oacute;n de los PUMs. Debido a que  estos m&eacute;todos no tratan de identificar los PUMs individuales, tambi&eacute;n  incluyen en las mediciones las superposiciones entre potenciales y el ruido.     <P>Por  otra parte, cada PUm es medido m&aacute;s de una vez, de manera que sus propiedades  est&aacute;n influenciadas por su frecuencia de descarga. Todo esto hace que los  valores calculados mediante estos m&eacute;todos no reflejen precisamente las  propiedades de los PUMs contenidos en la se&ntilde;al electromiogr&aacute;fica.<SUP>4,18-20</SUP>  El m&aacute;s conocido de estos m&eacute;todos es el implementado en la microcomputadora  ANOPS que ha sido desarrollada por <I>Kopec et al.</I><SUP>19</SUP>     <P>METODOS  DE DESCOMPOSICION DEL PATRON DE INTERFERENCIA (PI)     <P>Para este prop&oacute;sito  es de utilidad distinguir 2 niveles de la se&ntilde;al obtenida a partir de la  m&aacute;xima contracci&oacute;n: patr&oacute;n de interferencia parcial y patr&oacute;n  de interferencia total o lleno. El primero es aqu&eacute;l que contiene un alto  grado de superposici&oacute;n de PUMs y muy poca l&iacute;nea de base libre de  ruido. En un m&uacute;sculo normal esto podr&iacute;a corresponder a una contracci&oacute;n  supraumbral en un rango hasta de 5 % de la fuerza de contracci&oacute;n muscular  voluntaria m&aacute;xima, en la cual no se distinguen los PUMs individuales.<SUP>4</SUP>      ]]></body>
<body><![CDATA[<P>Seg&uacute;n estos 2 niveles de la se&ntilde;al, existen m&eacute;todos de  descomposici&oacute;n parcial del PI, cuyos seguidores son <I>Guiheneu et al</I>.<SUP>4,21</SUP>  y <I>Moschytz</I> y <I>De Figuereido et al.</I>,<SUP>4,22</SUP> y m&eacute;todos  de descomposici&oacute;n total del PI, desarrollados fundamentalmente por <I>McGill  et al.</I>,<SUP>5</SUP> quienes le llaman descomposici&oacute;n autom&aacute;tica  del EMG o ADEMG. Estos m&eacute;todos, a diferencia de los mencionados anteriormente  permiten el estudio de PUMs con umbrales de reclutamiento m&aacute;s altos, as&iacute;  como el estudio del reclutamiento y las descargas de los PUMs dentro de un rango  amplio de fuerzas de contracci&oacute;n.<SUP>4</SUP>     <P>Los primeros estudios  sobre la descomposici&oacute;n del patr&oacute;n de interferencia fueron hechos  por <I>De Luca et al</I>.<SUP>23,24</SUP> con el objetivo de estudiar el control  motor. Estas investigaciones fueron capaces de describir el comportamiento de  las descargas de grupos de 4 a 7 PUMs activos simult&aacute;neamente durante contracciones  musculares din&aacute;micas y est&aacute;ticas hasta de un 100 % de la contracci&oacute;n  m&aacute;xima en individuos normales y atletas entrenados. Este m&eacute;todo  utiliza electrodos especiales con superficie de contacto m&uacute;ltiple, de manera  que la configuraci&oacute;n de un PUM no se corresponde con aquellas consideradas  tradicionalmente en el EMG con aguja conc&eacute;ntrica. Adem&aacute;s de esto,  el m&eacute;todo requiere registros multicanales y un an&aacute;lisis fuera de  l&iacute;nea muy trabajoso con gran interacci&oacute;n por parte del operador.  Estas razones lo hacen poco adecuado para su aplicaci&oacute;n cl&iacute;nica.      <P>En contraposici&oacute;n a los m&eacute;todos que utilizan umbrales y contracci&oacute;n  ligera, los resultados obtenidos de la descomposici&oacute;n del patr&oacute;n  de interferencia no generan resultados que puedan ser comparados directamente  con los datos normativos de la escuela de Buchtal de EMG cuantitativo, aun usando  id&eacute;nticos electrodos, filtros y niveles de ganancia. Esto se debe a que  las propiedades de los PUMs reclutados m&aacute;s tard&iacute;amente difieren  de las de los potenciales de umbral m&aacute;s bajo.     <P>ANALISIS DEL PATRON DE  INTERFERENCIA     <P>Las mediciones autom&aacute;ticas sobre el patr&oacute;n de interferencia  tienen la ventaja de ser r&aacute;pidas y de incorporar se&ntilde;ales de potenciales  de mayor umbral de contracci&oacute;n que las que estudian los m&eacute;todos  de an&aacute;lisis de PUMs individuales. La principal desventaja del an&aacute;lisis  del patr&oacute;n de interferencia es que los par&aacute;metros que se miden,  generalmente no pueden relacionarse de forma simple y directa con las propiedades  de los PUMs constituyentes.     <P>Dentro de las propiedades del PI que pueden cuantificarse  tenemos los extremos relativos (picos), los cruces de la l&iacute;nea de base,  los puntos de inflexi&oacute;n, la amplitud, el &aacute;rea y la densidad del  espectro de potencia. Dentro de este grupo de m&eacute;todos tenemos los que a  continuaci&oacute;n se describen brevemente.     <P>ANALISIS DE TURNS     <P>Se denomina  <I>turns</I> a los cambios en la direcci&oacute;n de la se&ntilde;al electromiogr&aacute;fica  (m&aacute;ximo o m&iacute;nimo local) que superen cierto umbral de amplitud respecto  al <I>turn</I> anterior y al subsiguiente. Este concepto fue introducido por Willison<SUP>25,26</SUP>  utilizando 100 mV como umbral de amplitud.     <P>Un <I>turn</I> en el PI puede corresponder  a un pico dentro de un PUM, a una interacci&oacute;n entre PUMs superpuestos,  a ruido y a fluctuaciones de la l&iacute;nea de base. Su conteo, por tanto, reflejar&aacute;  de manera general el n&uacute;mero de PUMs activos, su polifasismo o complejidad  y su frecuencia de descarga.     <P>El criterio original de Willison ha sido extendido  y modificado por otros investigadores.<SUP>4,27,28</SUP> Existen al respecto fuertes  evidencias sobre la validez de los par&aacute;metros mayormente utilizados en  estudios aplicados a sujetos<SUP>28</SUP> y en simulaciones computadorizadas del  PI.<SUP>29,30</SUP>     ]]></body>
<body><![CDATA[<P>ANALISIS ESPECTRAL     <P>El PI, al igual que cualquier otra  se&ntilde;al, puede ser matem&aacute;ticamente descrito como una suma de senos  y cosenos de diferentes frecuencias usando la transformada de Fourier, la cual  proporciona un m&eacute;todo para la caracterizaci&oacute;n del PI acorde al espectro  de potencia. De forma general, el espectro del PI se asemeja a una "U" invertida  con un pico alrededor de los 100-200 Hz y un rango aproximado entre 10 y 2 000  Hz.     <P>Existen algunas evidencias de que los componentes de baja frecuencia del  espectro (10-50 Hz) tienden a reflejar la frecuencia de descarga de los PUMs,  mientras que los de mayores frecuencia est&aacute;n m&aacute;s relacionados con  la forma de los PUMs. En estudios realizados con sujetos normales, enfermos con  miopat&iacute;as y con enfermedades neur&oacute;genas no se han encontrado grandes  diferencias; sin embargo, este m&eacute;todo se ha usado ampliamente en el estudio  de la fatiga muscular.<SUP>4,31</SUP>     <P>ANALISIS DE INTEGRACION     <P>La medici&oacute;n  del &aacute;rea del PI mediante su rectificaci&oacute;n e integraci&oacute;n es  uno de los m&eacute;todos m&aacute;s antiguos para el an&aacute;lisis cuantitativo  del EMG.<SUP>4</SUP> La magnitud del PI integrado es una funci&oacute;n de la  amplitud y duraci&oacute;n de los PUMs individuales, as&iacute; como de su frecuencia  de descarga.<SUP>6</SUP> Su uso actual est&aacute; limitado fundamentalmente a  los estudios de kinesiolog&iacute;a que registran EMG de superficie.<SUP>4</SUP>      <P>Hasta aqu&iacute; hemos revisado algunos de los m&eacute;todos m&aacute;s utilizados  en los diferentes laboratorios a nivel mundial para el an&aacute;lisis autom&aacute;tico  cuantitativo de la se&ntilde;al electromiogr&aacute;fica. Muchos de ellos enfrentan  el problema de su aplicabilidad cl&iacute;nica, por lo que unos son m&aacute;s  usados que otros.     <P>CONCLUSION     <P>La utilizaci&oacute;n de m&eacute;todos cuantitativos  en el an&aacute;lisis del EMG le confiere a este procedimiento mayor confiabilidad,  objetividad y rapidez y a su vez se hace posible la comparaci&oacute;n de los  resultados entre diferentes laboratorios, en el tiempo y entre distintos expertos.      <P>SUMMARY     <P>The automated or semiautomated cuantitative methods applied to electromyography  are undoubtedly a step of advance in the scientific development of this speciality  and, in general, in its applications to clinical diagnosis. In the present paper  we make a review on this regard, expressing their advantages and disadvantages,  as well as their clinical applications.     ]]></body>
<body><![CDATA[<P><I>Key words:</I> <B>ELECTROMYOGRAPHY/methods;  AUTOMATION.</B>     <P>REFERENCIAS BIBLIOGRAFICAS <OL>     <!-- ref --><LI> <FONT SIZE=-1>Kimura J.  Electromyography: techniques and normal findings. En: Davis FA, ed. Electrodiagnosis  in diseases of nerve and muscle: principles and practice. Philadelphia: 1983;227-30.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>Buchthal F, Rosenfalck P. Action potential parameters in different  human muscles. Acta Psychiatr Scand 1955;30:125-31.</FONT></LI>    </OL><OL>     <!-- ref --><LI>  <FONT SIZE=-1>Stalberg E, Andreassen S, Falck B, Lang H, Rosenfalck A, Trojaborg  W. Quantitative analysis of individual motor unit potentials: a proposition for  standardized terminology and criteria for measurement. J Clin Neurophysiol 1986;3:313-48.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>Dorfman LJ, McGill KC. AAEE minimograph # 29: automatic quantitative  electromyography. Muscle Nerve 1988;11:804-10.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>McGill  KC, Cummins KL, Dorfman LJ. Automatic decomposition of the clinical electromyogram.  IEEE Trans Biomed Eng 1985;32: 470-7.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Richfield  EK, Cohen BA, Albers JW. Review of quantitative and automated meedle electromyographic  analysis. IEEE Trans Biomed Eng 1981;28:506-14.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Buchthal  F, Guld C, Rosenfalck P. Action potential parameters in normal muscle and their  dependence on physical variables. Acta Physiol Scand 1954;32:200.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>Czekajewski J, Ekstedt J, Stalberg E. Oscilloscopic recording of  muscle fibre action potentials. The window trigger and the delay unit. Electroencephalogr  Clin Neurophysiol 1969;27: 536-9.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Nissen Petersen  H, Guld C, Buchthal F. Adelay line to record random action potentials. Elkectroencephalogr  Clin Neurophysiol 1969;26:100-6.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Bergmans J. Computer  assisted on line measurements of motor unit potential in human electromyography.  Electromyogr Clin Neurophysiol 1971;11:161-81.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>_____.  Computer assisted measurement of the parameters of single motor unit potentials  in human electromyography. En: Desmedt JE, ed. New developments in neurophysiology.  Basel: Karger 1973; Vol 2:482-8.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Lee RG, White DG.  Computer analysis of motor unit action potentials in routine clinical electromyography.  En: Desmedt JE, ed. New developments in electromyography and clinical neurophysiology.  Basel: Karger, 1973; Vol 2:454-61.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Tanzi F, Tagliett  V, Zucca G, Arrigo A, Moglia A, Sandrini G. Computarized EMG analysis. Electromyogr  Clin Neurophysiol 1979;19:485-503.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Stalberg E, Antoni  L. Microprocessors in the analysis of the motor unit and neuromuscular transmisssion.  En: Yamaguchi, Fujisawa, eds. Recent advances in EEG and EMG data processing.  Amsterdam: Elsevier/North-Holland Biomedical, 1981:295-313.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Andreassen  S. Automatic mimicking of manual MUP analysis: seminar on automated quantification  of motor unit potentials. AAEE 1984;8-9.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Coatrieux  JL. On line electromyographic signal processing system. IEEE Trans Biomed Eng  1984;BME-31:199-207.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Rouvrais B, Toulouse P, Coatrieux  JL, Le Bars R. A possible method of automatic electromyhographic analysis and  diagnosis on line. Electromyogr Clin Neurophysiol 1983;23:457-70.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>Hausmanowa-Petrusewicz I. Some remarks on computer aided clinical  electromyography based on experience with the Polish ANOPS minicomputer. J Neurol  1986;233(2):77-82.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Kopec J. Quantitative evaluation  of EMG records based on digital indicators. Neurol Neurochir Pol 1986;20(1):18-23.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>_____. Methodological survey of automatic EMG analysis. Acta Physiol  Pol 1988;39(1):20-9.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Ghiheneuc P, Calamel J, Doncarli  C, Gitton D, Michel C. Automatic detection and pattern recognition of single motor  unit potentials in needle EMG. En: Desmedt JE, ed. Computer-Aided Electromyography.  Basel: Karger, 1983.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Gerber A, Studer RM, De Figueirede  RJP, Moschytz GS. A new framework and computer program for quantitative EMG signal  analysis. IEEE Trans Biomed Eng 1984;31:857-63.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Le  Fever RS, De Luca CJ. A procedure for decomposing the myoelectric signal into  its constituent action potentials. Part I: technique, theory and implementation.  IEEE Trans Biomed Eng 1982;29:149-57.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Le Fever RS,  Xenakis AP, De Luca CJ. A procedure for decomposing the myoelectric signal into  its constituent action potential. Part II: execution and test for accuracy. IEEE  Trans Biomed Eng 1982;29:158-64.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Willison RG. A  method of measuring motor unit activity in human muscle. J Physiol (Lond) 1963;168:35.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>______ . Analysis of electrical activity in healthy and distrophic  muscle in man. J Neurol Neurosurg Psychiatr 1964;27:386-94.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Nandedkar  SD, Sanders DB, Stalberg EV. Automatic analysis of the electromyographic interference  pattern. Part I: development of quantitative features. Muscle Nerve 1986;9:431-9.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>______ . Automatic analysis of the electromyographic interference  pattern. Part II: findings in control subjects and in some neuromuscular diseases.  Muscle Nerve 1986;9:491-500.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>______ . Simulation  and analysis of the electromyographic interference pattern in normal muscle. Part  I: turns and amplitude measurements. Muscle Nerve 1986;9:423-30.</FONT></LI>    <!-- ref --><LI>  <FONT SIZE=-1>______ . Simulation and analysis of the electromyographic interference  pattern in normal muscle. Part II: activity, upper centile amplitude and number  of small sements. Muscle Nerve 1986;9:486-90.</FONT></LI>    <!-- ref --><LI> <FONT SIZE=-1>Yaar  I, Niles L. EMG interference pattern power spectrum analysis in neuromuscular  disorders. Electromyogr Clin Neurophysiol 1989;29(7-8):473-89.</FONT></LI>    </OL>Recibido:  12 de octubre de 1995. Aprobado: 23 de noviembre de 1995.     <P>Dra. <I>Rebeca Hern&aacute;ndez  Toranzo</I>. Hospital Militar "Dr. Carlos J Finlay", Avenida 31, esquina a 114,  municipio Marianao, Ciudad de La Habana, Cuba.     </body> </HTML>        ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kimura]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electromyography: techniques and normal findings]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Davis]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
</person-group>
<source><![CDATA[Electrodiagnosis in diseases of nerve and muscle: principles and practice]]></source>
<year>1983</year>
<page-range>227-30</page-range><publisher-loc><![CDATA[Philadelphia ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buchthal]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenfalck]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Action potential parameters in different human muscles]]></article-title>
<source><![CDATA[Acta Psychiatr Scand]]></source>
<year>1955</year>
<volume>30</volume>
<page-range>125-31</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stalberg]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Andreassen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Falck]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Lang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenfalck]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Trojaborg]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quantitative analysis of individual motor unit potentials: a proposition for standardized terminology and criteria for measurement]]></article-title>
<source><![CDATA[J Clin Neurophysiol]]></source>
<year>1986</year>
<volume>3</volume>
<page-range>313-48</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dorfman]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[McGill]]></surname>
<given-names><![CDATA[KC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[AAEE minimograph # 29: automatic quantitative electromyography]]></article-title>
<source><![CDATA[Muscle Nerve]]></source>
<year>1988</year>
<volume>11</volume>
<page-range>804-10</page-range></nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McGill]]></surname>
<given-names><![CDATA[KC]]></given-names>
</name>
<name>
<surname><![CDATA[Cummins]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
<name>
<surname><![CDATA[Dorfman]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Automatic decomposition of the clinical electromyogram]]></article-title>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>1985</year>
<volume>32</volume>
<page-range>470-7</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Richfield]]></surname>
<given-names><![CDATA[EK]]></given-names>
</name>
<name>
<surname><![CDATA[Cohen]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
<name>
<surname><![CDATA[Albers]]></surname>
<given-names><![CDATA[JW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Review of quantitative and automated meedle electromyographic analysis]]></article-title>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>1981</year>
<volume>28</volume>
<page-range>506-14</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buchthal]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Guld]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Rosenfalck]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Action potential parameters in normal muscle and their dependence on physical variables]]></article-title>
<source><![CDATA[Acta Physiol Scand]]></source>
<year>1954</year>
<volume>32</volume>
<page-range>200</page-range></nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Czekajewski]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ekstedt]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Stalberg]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Oscilloscopic recording of muscle fibre action potentials: The window trigger and the delay unit]]></article-title>
<source><![CDATA[Electroencephalogr Clin Neurophysiol]]></source>
<year>1969</year>
<volume>27</volume>
<page-range>536-9</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nissen Petersen]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Guld]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Buchthal]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Adelay line to record random action potentials]]></article-title>
<source><![CDATA[Elkectroencephalogr Clin Neurophysiol]]></source>
<year>1969</year>
<volume>26</volume>
<page-range>100-6</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bergmans]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computer assisted on line measurements of motor unit potential in human electromyography]]></article-title>
<source><![CDATA[Electromyogr Clin Neurophysiol]]></source>
<year>1971</year>
<volume>11</volume>
<page-range>161-81</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="">
<article-title xml:lang="en"><![CDATA[Computer assisted measurement of the parameters of single motor unit potentials in human electromyography]]></article-title>
<person-group person-group-type="author">
<name>
<surname><![CDATA[Desmedt]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<source><![CDATA[New developments in neurophysiology]]></source>
<year>1973</year>
<page-range>482-8</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
<name>
<surname><![CDATA[White]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computer analysis of motor unit action potentials in routine clinical electromyography]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Desmedt]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<source><![CDATA[New developments in electromyography and clinical neurophysiology]]></source>
<year>1973</year>
<page-range>454-61</page-range><publisher-loc><![CDATA[Basel ]]></publisher-loc>
<publisher-name><![CDATA[Karger]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tanzi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Tagliett]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Zucca]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Arrigo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Moglia]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sandrini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Computarized EMG analysis]]></article-title>
<source><![CDATA[Electromyogr Clin Neurophysiol]]></source>
<year>1979</year>
<volume>19</volume>
<page-range>485-503</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Stalberg]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Antoni]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microprocessors in the analysis of the motor unit and neuromuscular transmisssion]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Yamaguchi]]></surname>
<given-names><![CDATA[Fujisawa]]></given-names>
</name>
</person-group>
<source><![CDATA[Recent advances in EEG and EMG data processing]]></source>
<year>1981</year>
<page-range>295-313</page-range><publisher-loc><![CDATA[Amsterdam ]]></publisher-loc>
<publisher-name><![CDATA[Elsevier/North-Holland Biomedical]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Andreassen]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<source><![CDATA[Automatic mimicking of manual MUP analysis: seminar on automated quantification of motor unit potentials]]></source>
<year>1984</year>
<page-range>8-9</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Coatrieux]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[On line electromyographic signal processing system]]></article-title>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>1984</year>
<volume>BME-31</volume>
<page-range>199-207</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rouvrais]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Toulouse]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Coatrieux]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Le Bars]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A possible method of automatic electromyhographic analysis and diagnosis on line]]></article-title>
<source><![CDATA[Electromyogr Clin Neurophysiol]]></source>
<year>1983</year>
<volume>23</volume>
<page-range>457-70</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hausmanowa-Petrusewicz]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Some remarks on computer aided clinical electromyography based on experience with the Polish ANOPS minicomputer]]></article-title>
<source><![CDATA[J Neurol]]></source>
<year>1986</year>
<volume>233</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>77-82</page-range></nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kopec]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quantitative evaluation of EMG records based on digital indicators]]></article-title>
<source><![CDATA[Neurol Neurochir Pol]]></source>
<year>1986</year>
<volume>20</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>18-23</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>_____</label><nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[Methodological survey of automatic EMG analysis]]></article-title>
<source><![CDATA[Acta Physiol Pol]]></source>
<year>1988</year>
<volume>39</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>20-9</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghiheneuc]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Calamel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Doncarli]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Gitton]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Michel]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Automatic detection and pattern recognition of single motor unit potentials in needle EMG]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Desmedt]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
</person-group>
<source><![CDATA[Computer-Aided Electromyography]]></source>
<year>1983</year>
<publisher-loc><![CDATA[Basel ]]></publisher-loc>
<publisher-name><![CDATA[Karger]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gerber]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Studer]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[De Figueirede]]></surname>
<given-names><![CDATA[RJP]]></given-names>
</name>
<name>
<surname><![CDATA[Moschytz]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new framework and computer program for quantitative EMG signal analysis]]></article-title>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>1984</year>
<volume>31</volume>
<page-range>857-63</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Le Fever]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
<name>
<surname><![CDATA[De Luca]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A procedure for decomposing the myoelectric signal into its constituent action potentials.: Part I: technique, theory and implementation]]></article-title>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>1982</year>
<volume>29</volume>
<page-range>149-57</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Le Fever]]></surname>
<given-names><![CDATA[RS]]></given-names>
</name>
<name>
<surname><![CDATA[Xenakis]]></surname>
<given-names><![CDATA[AP]]></given-names>
</name>
<name>
<surname><![CDATA[De Luca]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A procedure for decomposing the myoelectric signal into its constituent action potential.: Part II: execution and test for accuracy]]></article-title>
<source><![CDATA[IEEE Trans Biomed Eng]]></source>
<year>1982</year>
<volume>29</volume>
<page-range>158-64</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Willison]]></surname>
<given-names><![CDATA[RG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A method of measuring motor unit activity in human muscle]]></article-title>
<source><![CDATA[J Physiol (Lond)]]></source>
<year>1963</year>
<volume>168</volume>
<page-range>35</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[Analysis of electrical activity in healthy and distrophic muscle in man]]></article-title>
<source><![CDATA[J Neurol Neurosurg Psychiatr]]></source>
<year>1964</year>
<volume>27</volume>
<page-range>386-94</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nandedkar]]></surname>
<given-names><![CDATA[SD]]></given-names>
</name>
<name>
<surname><![CDATA[Sanders]]></surname>
<given-names><![CDATA[DB]]></given-names>
</name>
<name>
<surname><![CDATA[Stalberg]]></surname>
<given-names><![CDATA[EV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Automatic analysis of the electromyographic interference pattern.: Part I :development of quantitative features]]></article-title>
<source><![CDATA[Muscle Nerve]]></source>
<year>1986</year>
<volume>9</volume>
<page-range>431-9</page-range></nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[Automatic analysis of the electromyographic interference pattern.: Part II: findings in control subjects and in some neuromuscular diseases]]></article-title>
<source><![CDATA[Muscle Nerve]]></source>
<year>1986</year>
<volume>9</volume>
<page-range>491-500</page-range></nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[Simulation and analysis of the electromyographic interference pattern in normal muscle: Part I: turns and amplitude measurements]]></article-title>
<source><![CDATA[Muscle Nerve]]></source>
<year>1986</year>
<volume>9</volume>
<page-range>423-30</page-range></nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="journal">
<article-title xml:lang="en"><![CDATA[Simulation and analysis of the electromyographic interference pattern in normal muscle.: Part II :activity, upper centile amplitude and number of small sements]]></article-title>
<source><![CDATA[Muscle Nerve]]></source>
<year>1986</year>
<volume>9</volume>
<page-range>486-90</page-range></nlm-citation>
</ref>
<ref id="B31">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yaar]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Niles]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[EMG interference pattern power spectrum analysis in neuromuscular disorders]]></article-title>
<source><![CDATA[Electromyogr Clin Neurophysiol]]></source>
<year>1989</year>
<volume>29</volume>
<numero>7-8</numero>
<issue>7-8</issue>
<page-range>473-89</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
