<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-0300</journal-id>
<journal-title><![CDATA[Revista Cubana de Investigaciones Biomédicas]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Invest Bioméd]]></abbrev-journal-title>
<issn>0864-0300</issn>
<publisher>
<publisher-name><![CDATA[ECIMED]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-03002015000300001</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Efecto de la condición de carga en un implante dental mono componente sobre la distribución de esfuerzos en el hueso tipo IV]]></article-title>
<article-title xml:lang="en"><![CDATA[Effect of the loading condition of one-component dental implant on the stress distribution in a type IV quality bone]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sarria Popowski]]></surname>
<given-names><![CDATA[Perla]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González Ruíz]]></surname>
<given-names><![CDATA[Jesús Eduardo]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González Sánchez]]></surname>
<given-names><![CDATA[Diana Rosa]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Madrigal]]></surname>
<given-names><![CDATA[Melchor]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Rodríguez Fuentes]]></surname>
<given-names><![CDATA[Roberto]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Superior Politéctico José Antonio Echeverría Facultad de Ingeniería Mecánica Grupo Biomecánica]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de La Habana Centro de Biomateriales ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2015</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2015</year>
</pub-date>
<volume>34</volume>
<numero>3</numero>
<fpage>0</fpage>
<lpage>0</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-03002015000300001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-03002015000300001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-03002015000300001&amp;lng=en&amp;nrm=iso"></self-uri><kwd-group>
<kwd lng="es"><![CDATA[condición de carga]]></kwd>
<kwd lng="es"><![CDATA[implante dental monocomponente]]></kwd>
<kwd lng="es"><![CDATA[esfuerzos equivalentes de von Mises]]></kwd>
<kwd lng="es"><![CDATA[análisis por elementos finitos]]></kwd>
<kwd lng="es"><![CDATA[calidad ósea]]></kwd>
<kwd lng="es"><![CDATA[rosca cuadrada]]></kwd>
<kwd lng="en"><![CDATA[loading condition]]></kwd>
<kwd lng="en"><![CDATA[single component dental implant]]></kwd>
<kwd lng="en"><![CDATA[Von Mises equivalent stresses]]></kwd>
<kwd lng="en"><![CDATA[finite element analysis]]></kwd>
<kwd lng="en"><![CDATA[bone quality]]></kwd>
<kwd lng="en"><![CDATA[square thread]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  <font face="Verdana, Arial, Helvetica, sans-serif" size="2"></font>    <p align="right"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Rev    Cubana de Investigaciones Biom&#233;dicas. 2015;34(3)</b> </font></p>     <p align="right"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>ART&#205;CULO    ORIGINAL</b> </font></p>     <p align="right">&nbsp;</p>     <p> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="4">Efecto    de la condici&#243;n de carga en un implante dental mono componente sobre la    distribuci&#243;n de esfuerzos en el hueso tipo IV</font></b> </font></p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>Effect of the    loading condition of one-component dental implant on the stress distribution    in a type IV quality bone</b></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Ing. Perla Sarria    Popowski,<sup>I </sup>Dr. Jes&#250;s Eduardo Gonz&#225;lez Ru&#237;z,<sup>II    </sup>Ing. Diana Rosa Gonz&#225;lez S&#225;nchez,<sup>I </sup>Dr. Melchor Rodr&#237;guez    Madrigal,<sup>I </sup>Ing. </b> <b>Roberto Rodr&#237;guez Fuentes<sup>I</sup></b>    </font></p>     ]]></body>
<body><![CDATA[<p> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><sup>I</sup> Grupo    Biomec&#225;nica. Facultad de Ingenier&#237;a Mec&#225;nica. Instituto Superior    Polit&#233;cnico &#8220;Jos&#233; Antonio Echeverr&#237;a&#8221;, Cujae. La    Habana, Cuba.     <br>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><sup>II</sup>    Centro de Biomateriales. Universidad de La Habana. La Habana, Cuba. </font></p>     <p>&nbsp;</p>     <p>&nbsp;</p> <hr size="1" noshade>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>RESUMEN</b>    </font></p>     <p> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Introducci&#243;n:</b>    la capacidad de soportar cargas de los implantes dentales osteointegrados es    significativo, dependiente de su condici&#243;n de carga y de la calidad &#243;sea    de los maxilares.     <br>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Objetivo:</b>    analizar la influencia de la condici&#243;n de carga de un implante dental monocomponente    con rosca de perfil cuadrado, sobre la distribuci&#243;n de esfuerzos en el    hueso de calidad tipo IV.     <br>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>M&#233;todos:</b>    un modelo tridimensional de un segmento de maxilar humano con un implante dental    monocomponente, fue creado. Se us&#243; t&#233;cnicas de dise&#241;o <i>Computer    Assisted Design</i> y simulado su comportamiento mediante el <i>Finite Element    Method</i>. En la disimulo se usaron cuatro condiciones de carga del implante    dental: axial, buco-lingual, mesio-distal y combinada.     <br>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Resultados:</b>    en la interfaz hueso cortical - implante se obtuvieron los m&#225;ximos valores    de esfuerzos equivalentes, al evaluar la condici&#243;n de carga combinada.    Por otro lado, en la interfaz hueso trabecular &#8211; implante dental, la condici&#243;n    de carga combinada genera los m&#225;ximos valores de esfuerzos equivalentes,    en la parte inferior de la zona apical y los m&#237;nimos valores en la regi&#243;n    pr&#243;xima al hueso cortical.     <br>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Conclusiones:</b>    se obtuvo la distribuci&#243;n de esfuerzos en el implante dental y en su interfaz    con los huesos cortical y trabecular. La condici&#243;n de carga del nuevo implante    dental monocomponente estudiado, tiene influencia significativa sobre los niveles    de esfuerzos en el implante y en los huesos cortical y trabecular en maxilares    con calidad &#243;sea IV.     ]]></body>
<body><![CDATA[<br>   </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Palabras clave:</b>    condici&#243;n de carga, implante dental monocomponente, esfuerzos equivalentes    de von Mises, an&#225;lisis por elementos finitos, calidad &#243;sea, rosca    cuadrada. </font></p> <hr size="1" noshade>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><b>ABSTRACT</b></font>  </p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Introduction:    </b>the load-supporting capacity of osseointegrated dental implants is significant    depending on their loading condition and on the maxillae's bone quality.    <br>   <b>Objective: </b>to analyze the influence of the loading conditions of a single    component dental implant with square thread on the stress distribution in a    type IV quality bone.    <br>   <b>Methods:</b> a three-dimensional model of a human maxillary segment with    a single component dental implant was designed. The Computer Assisted Design    techniques were used for design together with the Finite Element Method to simulate    its behavior. Three loading conditions of the implant dental were examined:    axial, oral-lingual, mesiodistal and combined.    <br>   <b>Results: </b>the cortical bone-implant interface showed the highest equivalent    stress values when evaluating the combined loading condition. On the other hand,    in the trabecular bone-dental implant interface, the combined loading condition    generated the highest equivalent stress values just in the lower part of the    apical area and the lowest values in the proximal region to the cortical bone.    <br>   <b>Conclusions:</b> the stress distribution in the dental implant and in its    interface within the cortical bone and the trabecular bone were shown in this    study. The loading condition of the new single component dental implant has    a significant effect on the levels of stress in the implant and in the cortical    and trabecular bones located in the type IV osseous quality maxillae.</font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Keywords:</b>    loading condition, single component dental implant, Von Mises equivalent stresses,    finite element analysis, bone quality, square thread.</font></p> <hr size="1" noshade>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="3">INTRODUCCI&#211;N</font></b>    </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Los procedimientos    quir&#250;rgicos y prot&#233;sicos en la odontolog&#237;a han evolucionado en    funci&#243;n de responder a la necesidad de lograr rehabilitaciones m&#225;s    eficaces y satisfactorias para los pacientes. Con este prop&#243;sito, los implantes    end&#243;seos son usados como sustituto de la ra&#237;z del diente, en pacientes    parcial o total, ed&#233;ntulos.<sup>1</sup> </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> En la tasa de    &#233;xito de este tipo de tratamiento, a&#250;n se reportan fracasos relacionados    con la biomec&#225;nica del implante.<sup>2 </sup>El an&#225;lisis mediante    el <i>Finite Element Method</i> (FEM) ha sido aplicado por muchos autores para    pronosticar el comportamiento biomec&#225;nico de los implantes dentales.<sup>3    </sup>En los modelos se tienen en cuenta par&#225;metros tales como; la geometr&#237;a    del implante, la matriz &#243;sea del sistema mandibular, la magnitud y la direcci&#243;n    de las fuerzas masticatorias. Los esfuerzos, las deformaciones son obtenidos    en todo el volumen de control, se usa FEM. </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Alrededor de los    implantes end&#243;seos, se observa una peque&#241;a p&#233;rdida de hueso,<sup>    </sup>cuya causa es vinculada con los niveles de esfuerzos y deformaciones.<sup>4,5    </sup>La relaci&#243;n entre el esfuerzo y la p&#233;rdida &#243;sea ha sido    reportada en diferentes trabajos.<sup>6 </sup>El proceso de reabsorci&#243;n    &#243;sea afecta m&#225;xime, la regi&#243;n roscada en la interfaz hueso implante.<sup>7,8    </sup>Los esfuerzos alrededor del implante end&#243;seo son afectados por factores    biomec&#225;nicos tales como; el tipo de carga, las propiedades del material    del implante, su geometr&#237;a, la superficie, la calidad y cantidad de hueso    circundante al implante.<sup>4,9</sup> </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> La fuerza masticatoria    es aplicada en la interfaz hueso - implante en tres direcciones principales:    axial, meso distal y buco lingual.<sup>10 </sup>La magnitud de estas fuerzas    afecta la distribuci&#243;n de los esfuerzos en el implante y la matriz &#243;sea.    El efecto combinado de las fuerzas masticatorias ha sido valorado, se aplica    el m&#233;todo de los Elementos Finitos.<sup>5</sup> </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Se ha demostrado    que el dise&#241;o del implante tiene una influencia significativa sobre el    nivel de esfuerzo en el hueso.<sup>11,12 </sup>Adem&#225;s, hay otros factores    que influyen en los esfuerzos del hueso alrededor del implante; como la inclinaci&#243;n    y forma de la rosca.<sup>8,13,14 </sup> Diferentes formas de perfil roscado    se emplean en los implantes dentales: triangular, cuadrada y tipo sierra.<sup>8,13</sup>    </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> La calidad de    hueso tambi&#233;n, tiene influencia sobre los esfuerzos en la interfaz - hueso    implante. Seg&#250;n <i>Lekholm </i>y<i> Zarb</i>,<sup>11 </sup>existen cuatro    tipos de calidad &#243;sea. La tasa de &#233;xito de los implantes colocados    en hueso con calidad IV oscila entre 50 and 80 %.<sup>11</sup> </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> El objetivo de    este trabajo es analizar el efecto de las condiciones de carga de un implante    dental monocomponente roscado con perfil cuadrado, en la distribuci&#243;n de    esfuerzos en hueso con calidad &#243;sea IV. </font></p>     <p>&nbsp; </p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="3">M&#201;TODOS</font></b>    </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Un implante dental    monocomponente anclado, con perfil de rosca cuadrado, de paso 1.2 mm, di&#225;metro    m&#225;ximo 3.8 mm y la longitud de contacto hueso implante 13 mm, ha sido utilizado    para el estudio. Un segmento tridimensional de la regi&#243;n molar de una mand&#237;bula    humana, donde ha sido fijado el implante dental monocomponente, fue modelado,    se emple&#243; t&#233;cnicas de (Dise&#241;o Asistido por Computadoras por sus    siglas en ingl&#233;s) (CAD) y el m&#233;todo de c&#225;lculo de esfuerzos y    deformaciones FEM. </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Este segmento    est&#225; formado por hueso tipo IV y compuesto por dos vol&#250;menes (<a href="#fig1">Fig.    1A</a>): una capa exterior de hueso cortical, con espesor de alrededor de 0,5    mm y una interior de hueso trabecular. La longitud del segmento &#243;seo a    lo largo de la direcci&#243;n meso-distal es de alrededor de 10 mm, mientras    que su altura media es cerca de de 32 mm. El implante fue colocado en la mitad    del segmento &#243;seo. En el modelo se consideraron diferentes niveles de refinamiento    de la malla de elementos finitos, se us&#243; un criterio de convergencia. A    &#250;ltima hora, fue utilizada una malla con 185805 nodos y 193727 elementos.    </font></p>     <p align="center"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><a name="fig1"></a>    <img src="/img/revistas/ibi/v34n3/f0101315.jpg" width="420" height="410"> </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Las cargas fueron    aplicadas en la superficie superior de implante. Estuvieron empleadas cuatro    cargas diferentes; axial, buco lingual, meso distal y combinadas, con valores:    114,6 N, 17,1 N y 23,4 N al respecto, (<a href="#fig1">Fig. 1B</a>). De acuerdo    con <i>Himmlova</i>,<sup>10 </sup>estas condiciones de carga simulan el efecto    de la fuerza masticatoria media de 118,2 N, en la direcci&#243;n del &#225;ngulo    de 75&#176; con el plano oclusal. Las propiedades materiales del implante y    el hueso se tomaron seg&#250;n lo reportado por <i>Lin</i>.<sup>15 </sup>Para    el hueso trabecular de densidad 0,5 g/cm <sup>3</sup> el M&#243;dulo de Elasticidad    es de 696 MPa y para el hueso cortical de densidad 1,7 g/cm<sup>3 </sup>es de    13 000 MPa. El coeficiente de Poisson es de 0,3 para ambos. Para el implante    de Ti-6Al-4V el M&#243;dulo de Elasticidad es de 113 000 MPa y Poisson 0,35.    </font></p>     <p align="center">&nbsp; </p>     <p> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="3">RESULTADOS    </font> </b> </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> En la <a href="#fig2">figura    2</a> se muestran los esfuerzos equivalentes en el cuerpo del implante de una    aleaci&#243;n de titanio tipo Ti6AlV4 para las cuatro condiciones de carga simuladas.    Los mayores valores de esfuerzos se obtuvieron en el pilar y en la zona roscada    pr&#243;xima al cuello del implante. Adem&#225;s, en todas las condiciones de    carga simuladas el menor nivel de esfuerzos, se observa en la zona exterior    de la rosca. Por otro lado, al comparar los cuatro modelos, se aprecian diferencias    entre los niveles de esfuerzos m&#225;ximos obtenidos, fueron las mayores para    la carga combinada, (<a href="#fig2">Fig. 2D</a>). Estos esfuerzos no representan    peligro de colapso del implante. </font></p>     <p align="center"><a name="fig2"></a> <img src="/img/revistas/ibi/v34n3/f0201315.jpg" width="480" height="740"></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> En la <a href="/img/revistas/ibi/v34n3/f0301315.jpg">figura    3 </a>se observa que las cuatro condiciones de carga estudiadas generan las    mayores concentraciones de esfuerzos en la parte superior del hueso cortical,    pr&#243;ximo al cuello de implante. Adem&#225;s, los esfuerzos m&#225;ximos    se obtuvieron al utilizar la condici&#243;n de carga combinada. </font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Para la condici&#243;n    de cargas combinadas figura 3D, se observa que los esfuerzos alrededor del implante    est&#225;n en un rango de 12 a 24 MPa. Sin embargo, una excepci&#243;n de este    comportamiento est&#225; en la cara distal, de la zona superior del hueso cortical    (ampliaci&#243;n en la <a href="/img/revistas/ibi/v34n3/f0301315.jpg">figura 3 </a>), donde prevalecen    tensiones entre 0,2 y 6,4 MPa. </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Las cuatro condiciones    de carga aplicadas, generaron los mayores valores de esfuerzos equivalentes    dentro del hueso trabecular, en el &#225;rea correspondiente a la parte inferior    de la regi&#243;n apical (<a href="/img/revistas/ibi/v34n3/f0401315.jpg">Fig. 4</a>). En el exterior    de la rosca, hay peque&#241;as &#225;reas (ampliaci&#243;n en la <a href="/img/revistas/ibi/v34n3/f0401315.jpg">figura    4</a>) donde est&#225;n concentrados los mayores valores de los esfuerzos (7,7    MPa bajo la carga combinada). </font></p>     <p align="center">&nbsp; </p>     <p> <font face="Verdana, Arial, Helvetica, sans-serif" size="3"><b>DISCUSI&#211;N    </b> </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> El &#233;xito    de los implantes dentales depende de la influencia en la trasmisi&#243;n de    esfuerzos del implante a la matriz &#243;sea, de la calidad &#243;sea, de la    geometr&#237;a del implante, y de las condiciones de carga.<sup>11,13,16,17    </sup>Los resultados muestran la posibilidad de implementar en el modelo, la    carga combinada que representa los efectos masticatorios sobre la estructura    implante y matriz &#243;sea. </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Los niveles de    esfuerzos, al igual que los resultados reportados en la literatura,<sup>18-20    </sup>facilitan la remodelaci&#243;n &#243;sea para la densidad del hueso cortical    y trabecular evaluado. </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> La<a href="#fig5">    figura 5</a> muestra la distribuci&#243;n de esfuerzos en el implante y en los    huesos cortical y trabecular. La carga axial genera mayores tensiones que el    resto de las direcciones de carga estudiadas. Este resultado corrobora que la    distribuci&#243;n de tensiones depende, entre otros factores, de la direcci&#243;n    de la carga. El efecto combinado de las cargas, aporta los mayores valores de    esfuerzos tanto para el implante, como para los huesos trabecular y cortical.    </font></p>     <p align="center"><a name="fig5"></a> <img src="/img/revistas/ibi/v34n3/f0501315.jpg" width="577" height="325"></p>     <p>&nbsp; </p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="3">REFERENCIAS    BIBLIOGR&#193;FICAS</font></b> </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 1. Van-Oosterwick    H, Duyck J, Vander Sloten J, Vander Perre G, De Cooman M, Lievens S, et al.    The influence of bone mechanical properties and implant fixation upon bone loading    around oral implant. Clin Oral Implants Res. 1998;9(6):407-18.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 2. Simonis P,    Dufour T, Tenenbaum H. Long&#8208;term implant survival and success: a 10&#8211;16&#8208;year    follow&#8208;up of non&#8208;submerged dental implants. Clin Oral Implants Res.    2010;21(7):772-7.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 3. Cheng HY, Chu    KT, Shen FC, Pan YN, Chou HH, Ou KL, et al. Stress effect on bone remodeling    and osseointegration on dental implant with novel nano/microporous surface functionalization.    J Biomed Mater Res A. 2013;101(4):1158-64.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 4. Assenza B,    Scarano A, Perrotti V, Vozza I, Quaranta A. Peri-implant bone reactions around    immediately loaded conical implants with different prosthetic suprastructures:    histological and histomorphometrical study on minipigs. Clin Oral Invest. 2010;14(3):285-90.        </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 5. Mahajan A,    Kadam KN. The Influence of Mechanical Loads on the Biomechanics of Dental Implant.    Int J Sci Res. 2014;3(11):1085-90.     </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 6. Lin CL, Lin    YH, Chang SH. Multi-factorial analysis of variables influencing the bone loss    of an implant placed in the maxilla: Prediction using FEA and SED bone remodeling    algorithm. J Biomech. 2010;43(4):644-51.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 7. Shelat S, Kularashmi    BS, Annapoorani H, Chakravarthy R. Effect of two different abutment types on    stress distribution in the bone around an implant under two loading conditions.    J Dent Implant. 2011;1(2):80-5.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 8. Lan TH, Du    JK, Pan CY, Lee HE, Chung WH. Biomechanical analysis of alveolar bone stress    around implants with different thread designs and pitches in the mandibular    molar area. Clin Oral Invest. 2012;16(2):363-9.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 9. Merdji A, Bouiadjra    BB, Chikh BO, Mootanah R, Aminallah L, Serier B, et al. Stress distribution    in dental prosthesis under an occlusal combined dynamic loading. Mater Design.    2012;36(1):705-13.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 10. Himmlova L,    Dostalova T, Kacovsky A, Konvickova S. Influence of implant length and diameter    on stress distribution: A finite element analysis. J Prosthet Dent. 2004;91:(1):20-5.        </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 11. Sevimay M,    Turhan F, Kilicarslan MA, Eskitascioglu G. Three-dimensional finite element    analysis of the effect of different bone quality on stress distribution in an    implant-supported crown. J Prosthet Dent. 2005;93(3):227-34.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 12. Li T, Kong    L, Wang Y, Hu K, Song L, Liu B, et al. Selection of optimal dental implant diameter    and length in type IV bone: a three-dimensional finite element analysis. Int    J Oral Maxillofac Surg. 2009;38(10):1077-83.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 13. Anitua E,    Tapia R, luzoriaga F, Orive G. Influence of implant length, Diameter and Geometry    on Stress Distribution: A Finite Element Analysis. Int J Periodont Restorative    Dent. 2010;30(1):89-95.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 14. Faegh S, Sinan    M. Load transfer along the bone &#8211; dental implant interface. J Biomech.    2010;43(9):1761-70.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 15. Lin D, Li    Q, Li W, Swain M. Dental implant induced bone remodeling and associated algorithms.    J Mech Behav Biomed Mater. 2009;2(5):410-32.     </font></p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 16. Eraslan O,    &#304;nan &#214;. The effect of thread design on stress distribution in a solid    screw implant: a 3D finite element analysis. Clin Oral Investig. 2010;14(4):411-6.    </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 17. &#350;ahin    S, Cehreli MC, Yalcin E. The influence of functional forces on the biomechanics    of implant-supported prostheses-a review. J Dent. 2002;30(7):271-82. </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 18. Djebbar N,    Serier B, Bouiadjra BB, Benbarek S, Drai A. Analysis of the effect of load direction    on the stress distribution in dental implant. Mater Design. 2010;31(4):2097-101.        </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 19. Okumura N,    Stegaroiu R, Kitamura E, Kurokawa K, Nomura S. Influence of maxillary cortical    bone thickness, implant design and implant diameter on stress around implants:    a three-dimensional finite element analysis. J Prosthodont Res. 2010;54(3):133-42.        </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 20. Wang C, Li    Q, McClean C, Fan Y. Numerical simulation of dental bone remodeling induced    by implant-supported fixed partial denture with or without cantilever extension.    Int J Numer Methods Biomed Eng. 2013;29(10):1134-47.     </font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Recibido: 2 de    mayo de 2015.     <br>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Aprobado:    3 de junio de 2015. </font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><i>Perla Sarria    </i> <i>Popowski.</i> Grupo Biomec&#225;nica. Facultad de Ingenier&#237;a Mec&#225;nica.    Instituto Superior Polit&#233;cnico &#8220;Jos&#233; Antonio Echeverr&#237;a&#8221;    Cujae. 119 s/n, Marianao, La Habana, Cuba. </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">     ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Van-Oosterwick]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Duyck]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Vander Sloten]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Vander Perre]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[De Cooman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Lievens]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The influence of bone mechanical properties and implant fixation upon bone loading around oral implant]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>1998</year>
<volume>9</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>407-18</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Simonis]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dufour]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Tenenbaum]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Long-term implant survival and success: a 10-16-year follow-up of non-submerged dental implants]]></article-title>
<source><![CDATA[Clin Oral Implants Res]]></source>
<year>2010</year>
<volume>21</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>772-7</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cheng]]></surname>
<given-names><![CDATA[HY]]></given-names>
</name>
<name>
<surname><![CDATA[Chu]]></surname>
<given-names><![CDATA[KT]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[FC]]></given-names>
</name>
<name>
<surname><![CDATA[Pan]]></surname>
<given-names><![CDATA[YN]]></given-names>
</name>
<name>
<surname><![CDATA[Chou]]></surname>
<given-names><![CDATA[HH]]></given-names>
</name>
<name>
<surname><![CDATA[Ou]]></surname>
<given-names><![CDATA[KL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Stress effect on bone remodeling and osseointegration on dental implant with novel nano/microporous surface functionalization]]></article-title>
<source><![CDATA[J Biomed Mater Res A]]></source>
<year>2013</year>
<volume>101</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>1158-64</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Assenza]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Scarano]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Perrotti]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Vozza]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Quaranta]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Peri-implant bone reactions around immediately loaded conical implants with different prosthetic suprastructures: histological and histomorphometrical study on minipigs]]></article-title>
<source><![CDATA[Clin Oral Invest]]></source>
<year>2010</year>
<volume>14</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>285-90</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mahajan]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kadam]]></surname>
<given-names><![CDATA[KN]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Influence of Mechanical Loads on the Biomechanics of Dental Implant]]></article-title>
<source><![CDATA[Int J Sci Res]]></source>
<year>2014</year>
<volume>3</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1085-90</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[YH]]></given-names>
</name>
<name>
<surname><![CDATA[Chang]]></surname>
<given-names><![CDATA[SH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Multi-factorial analysis of variables influencing the bone loss of an implant placed in the maxilla: Prediction using FEA and SED bone remodeling algorithm]]></article-title>
<source><![CDATA[J Biomech]]></source>
<year>2010</year>
<volume>43</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>644-51</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shelat]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Kularashmi]]></surname>
<given-names><![CDATA[BS]]></given-names>
</name>
<name>
<surname><![CDATA[Annapoorani]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Chakravarthy]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of two different abutment types on stress distribution in the bone around an implant under two loading conditions]]></article-title>
<source><![CDATA[J Dent Implant]]></source>
<year>2011</year>
<volume>1</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>80-5</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lan]]></surname>
<given-names><![CDATA[TH]]></given-names>
</name>
<name>
<surname><![CDATA[Du]]></surname>
<given-names><![CDATA[JK]]></given-names>
</name>
<name>
<surname><![CDATA[Pan]]></surname>
<given-names><![CDATA[CY]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[HE]]></given-names>
</name>
<name>
<surname><![CDATA[Chung]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biomechanical analysis of alveolar bone stress around implants with different thread designs and pitches in the mandibular molar area]]></article-title>
<source><![CDATA[Clin Oral Invest]]></source>
<year>2012</year>
<volume>16</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>363-9</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Merdji]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bouiadjra]]></surname>
<given-names><![CDATA[BB]]></given-names>
</name>
<name>
<surname><![CDATA[Chikh]]></surname>
<given-names><![CDATA[BO]]></given-names>
</name>
<name>
<surname><![CDATA[Mootanah]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Aminallah]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Serier]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Stress distribution in dental prosthesis under an occlusal combined dynamic loading]]></article-title>
<source><![CDATA[Mater Design]]></source>
<year>2012</year>
<volume>36</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>705-13</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Himmlova]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Dostalova]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kacovsky]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Konvickova]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of implant length and diameter on stress distribution: A finite element analysis]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2004</year>
<volume>91</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>20-5</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sevimay]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Turhan]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Kilicarslan]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Eskitascioglu]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Three-dimensional finite element analysis of the effect of different bone quality on stress distribution in an implant-supported crown]]></article-title>
<source><![CDATA[J Prosthet Dent]]></source>
<year>2005</year>
<volume>93</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>227-34</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Kong]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Hu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Song]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Selection of optimal dental implant diameter and length in type IV bone: a three-dimensional finite element analysis]]></article-title>
<source><![CDATA[Int J Oral Maxillofac Surg]]></source>
<year>2009</year>
<volume>38</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1077-83</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Anitua]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Tapia]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[luzoriaga]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Orive]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of implant length, Diameter and Geometry on Stress Distribution: A Finite Element Analysis]]></article-title>
<source><![CDATA[Int J Periodont Restorative Dent]]></source>
<year>2010</year>
<volume>30</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>89-95</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Faegh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sinan]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Load transfer along the bone - dental implant interface]]></article-title>
<source><![CDATA[J Biomech]]></source>
<year>2010</year>
<volume>43</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1761-70</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Swain]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Dental implant induced bone remodeling and associated algorithms]]></article-title>
<source><![CDATA[J Mech Behav Biomed Mater]]></source>
<year>2009</year>
<volume>2</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>410-32</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eraslan]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Inan]]></surname>
<given-names><![CDATA[Ö]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The effect of thread design on stress distribution in a solid screw implant: a 3D finite element analysis]]></article-title>
<source><![CDATA[Clin Oral Investig]]></source>
<year>2010</year>
<volume>14</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>411-6</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sahin]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Cehreli]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Yalcin]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The influence of functional forces on the biomechanics of implant-supported prostheses-a review]]></article-title>
<source><![CDATA[J Dent]]></source>
<year>2002</year>
<volume>30</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>271-82</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Djebbar]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Serier]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Bouiadjra]]></surname>
<given-names><![CDATA[BB]]></given-names>
</name>
<name>
<surname><![CDATA[Benbarek]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Drai]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of the effect of load direction on the stress distribution in dental implant]]></article-title>
<source><![CDATA[Mater Design]]></source>
<year>2010</year>
<volume>31</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>2097-101</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Okumura]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Stegaroiu]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kitamura]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Kurokawa]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Nomura]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of maxillary cortical bone thickness, implant design and implant diameter on stress around implants: a three-dimensional finite element analysis]]></article-title>
<source><![CDATA[J Prosthodont Res]]></source>
<year>2010</year>
<volume>54</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>133-42</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[McClean]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Fan]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Numerical simulation of dental bone remodeling induced by implant-supported fixed partial denture with or without cantilever extension]]></article-title>
<source><![CDATA[Int J Numer Methods Biomed Eng]]></source>
<year>2013</year>
<volume>29</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1134-47</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
