<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-215X</journal-id>
<journal-title><![CDATA[Revista Cubana de Ortopedia y Traumatología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Ortop Traumatol]]></abbrev-journal-title>
<issn>0864-215X</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-215X2022000400009</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[MIPO con placa helicoidal en fractura de húmero]]></article-title>
<article-title xml:lang="en"><![CDATA[MIPO with helical plate in humeral fracture]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vargas Morales]]></surname>
<given-names><![CDATA[Renán Estuardo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Zavaleta Alfaro]]></surname>
<given-names><![CDATA[Ricardo Luis]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lozano Peralta]]></surname>
<given-names><![CDATA[Katherine Yolanda]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Privada Antenor Orrego Facultad de Medicina Humana ]]></institution>
<addr-line><![CDATA[Trujillo ]]></addr-line>
<country>Peru</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2022</year>
</pub-date>
<volume>36</volume>
<numero>4</numero>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-215X2022000400009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-215X2022000400009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-215X2022000400009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN  Introducción:  Las fracturas humerales diafisarias multifragmentarias con extensión proximal son patrones infrecuentes de lesión causados principalmente por trauma de alta energía. La forma anatómica del húmero, la presencia de la tuberosidad deltoidea y la proximidad del nervio radial al surco radial representan retos a tratar, por ello se recomiendan incisiones mínimamente invasivas y la estabilización de la fractura con placa proximal humeral internal locking system.  Objetivo:  Demostrar la eficacia de la técnica minimally invasive plate osteosynthesis con el moldeamiento helicoidal de la placa proximal humeral internal locking system.  Presentación del caso:  Paciente de 29 años que sufrió accidente de tránsito y presentó fractura diafisaria multifragmentaria extendida al húmero proximal. Se trató con la técnica minimally invasive plate osteosynthesis y placa helicoidal proximal humeral internal locking system. Alcanzó la consolidación completa y rápida recuperación funcional.  Conclusiones: La técnica minimally invasive plate osteosynthesis con placa helicoidal proximal humeral internal locking system es una opción quirúrgica eficaz y segura para las fracturas humerales diafisarias multifragmentarias con extensión proximal, ya que preserva la inserción muscular deltoidea, mejora el contacto placa hueso con riesgo mínimo de lesión neurológica axilar y radial, favorece la curación ósea y mejora el resultado funcional.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT  Introduction:  Multifragmentary diaphyseal humeral fractures with proximal extension are infrequent patterns of injury caused mainly by high-energy trauma. The anatomical shape of the humerus, the presence of the deltoid tuberosity and the proximity of the radial nerve to the radial groove represent challenges to be treated, therefore minimally invasive incisions and fracture stabilization with the proximal humeral internal locking system plate are recommended.  Objective:  To establish the efficacy of the minimally invasive plate osteosynthesis technique with helical molding of the proximal humeral plate internal locking system.  Case report:  We report the case of a 29-year-old patient who suffered a traffic accident and had a multifragmentary diaphyseal fracture extended to the proximal humerus. He was treated with the minimally invasive plate osteosynthesis technique and the humeral proximal helical plate internal locking system. He achieved complete consolidation and rapid functional recovery.  Conclusions:  The minimally invasive plate osteosynthesis technique with the humeral proximal helical plate internal locking system is an effective and safe surgical option for multifragmentary diaphyseal humeral fractures with proximal extension, since it preserves the deltoid muscle insertion, improves bone-plate contact with minimal risk of fracture. Axillary and radial neurological injury, promotes bone healing and improves functional outcome.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[húmero]]></kwd>
<kwd lng="es"><![CDATA[fractura diafisiaria]]></kwd>
<kwd lng="es"><![CDATA[multifragmentaria]]></kwd>
<kwd lng="es"><![CDATA[philos helicoidal]]></kwd>
<kwd lng="es"><![CDATA[mipo]]></kwd>
<kwd lng="en"><![CDATA[humerus]]></kwd>
<kwd lng="en"><![CDATA[multifragmentary diaphyseal fracture]]></kwd>
<kwd lng="en"><![CDATA[helical blade]]></kwd>
<kwd lng="en"><![CDATA[mipo]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nicolaci]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Lollino]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[How to treat proximal and middle one-third humeral shaft fractures The role of helical plates]]></article-title>
<source><![CDATA[Surgical Techniques Development]]></source>
<year>2021</year>
<volume>10</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zamboni]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Durigan]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Diaz Pimentel]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Soares Hungria]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Tomanik Mercadante]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[de Moraes Barros]]></surname>
<given-names><![CDATA[PM]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Rotational evaluation of humeral shaft fractures with proximal extension fixed using the MIPO technique]]></article-title>
<source><![CDATA[Injury, Int. J. Care Injured]]></source>
<year>2018</year>
<volume>49</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1558-61</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Da Silva]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Rummel]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Knop]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparing iatrogenic radial nerve lesions in humeral shaft fractures treated with helical or straight PHILOS plates a 10-year retrospective cohort study of 62 cases]]></article-title>
<source><![CDATA[Arch Orthop Trauma Surg]]></source>
<year>2020</year>
<volume>140</volume>
<page-range>1931-7</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moon]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kwon]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Biraris]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Shon]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Minimally Invasive Plate Osteosynthesis Using a Helical Plate for Metadiaphyseal Complex Fractures of the Proximal Humerus]]></article-title>
<source><![CDATA[Orthopedics]]></source>
<year>2014</year>
<volume>37</volume>
<numero>3</numero>
<issue>3</issue>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Narayanan]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Balasubramanian]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Complex Proximal Humeral Fracture Fixation with PHILOS Plate using Minimal Invasive Percutaneous Plate Osteosynthesis (MIPPO) Technique A Series of 30 Patients]]></article-title>
<source><![CDATA[Malaysian Orthopaedic Journal]]></source>
<year>2018</year>
<volume>12</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>20-4</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Levy]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Herrera]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Templeman]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Cole]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Segmental Proximal Humerus Fractures A Case Report of Submuscular Plating]]></article-title>
<source><![CDATA[J Trauma]]></source>
<year>2008</year>
<volume>65</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1554-7</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rupenian]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Lebas]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Raza]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Herrador]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[D´assaro]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Osteosíntesis mínimamente invasiva con placa helicoidal en fracturas diafisarias del húmero con compromiso del tercio proximal. Informe de un caso y descripción de la técnica]]></article-title>
<source><![CDATA[Rev Asoc Argent Ortop Traumatol]]></source>
<year>2005</year>
<volume>70</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>252-5</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Belangero]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Zublin]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Cárdenas]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Suárez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Alvachian]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Martinez]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Quick-DASH as a main early outcome of humeral shaft fractures A Latin American multicenter prospective study]]></article-title>
<source><![CDATA[Journal of Orthopaedic Surgery]]></source>
<year>2020</year>
<volume>28</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1-7</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Da Silva]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Rummel]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Knop]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Merkle]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Shoulder function after helical long PHILOS plate]]></article-title>
<source><![CDATA[Eur J Orthop Surg Traumatol]]></source>
<year>2021</year>
<volume>31</volume>
<page-range>1463-9</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dauwe]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Grechenig]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Unterfrauner]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Schwarz]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Weiglein]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hohenberger]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Axillary nerve elongation in humeral fracture plating A cadaveric study for comparison between straight and helical Philos plates]]></article-title>
<source><![CDATA[J Orthop]]></source>
<year>2020</year>
<volume>19</volume>
<page-range>233-6</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Maes]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Putzeys]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<source><![CDATA[One-Year Follow-Up After Treatment of Proximal and/or Middle One-Third Humeral Shaft Fractures with a Helical Plate: Healing Rates, Complications and Functional Outcome Measures]]></source>
<year>2019</year>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Meinberg]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Agel]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Roberts]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Karam]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kellam]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Fracture and Dislocation Classification Compendium-2018, Journal of Orthopaedic]]></article-title>
<source><![CDATA[Trauma]]></source>
<year>2018</year>
<volume>32</volume>
<page-range>1-0</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Byun]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Shin]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gu]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Helical Plating for Fractures of the Proximal Humeral Shaft]]></article-title>
<source><![CDATA[J Korean Orthop Assoc]]></source>
<year>2017</year>
<volume>52</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>232-9</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[García-Virto]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Santiago-Maniega]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Llorente-Peris]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Simón-Pérez]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Álvarez-Ramos]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[García-Florez]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[MIPO helical pre-contoured plates in diaphyseal humeral fractures with proximal extension Surgical technique and results]]></article-title>
<source><![CDATA[Injury]]></source>
<year>2021</year>
<volume>52</volume>
<numero>Supl4</numero>
<issue>Supl4</issue>
<page-range>125-30</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ekdahl]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Domínguez]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Pinedo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Gutiérrez]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[New precontoured long locking plate for proximal metadiaphyseal fractures of the humerus a cadaveric study for its use with the minimally invasive technique]]></article-title>
<source><![CDATA[JSES Int]]></source>
<year>2021</year>
<volume>5</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>540-5</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Touloupakis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Di Giorgio]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Bibiano]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Biancardi]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Ghirardelli]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sinno]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Exploring the difficulties to improve minimally invasive application with long PHILOS plate in multifocal metadiaphyseal fractures of the proximal humerus analysis of intraoperative procedure and clinical outcomes]]></article-title>
<source><![CDATA[Acta Biomed]]></source>
<year>2018</year>
<volume>89</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>532-9</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zamboni]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Carmo]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Moraes]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Hungría]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mercadante]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Fucs]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A practical guide for the use of contour locking plates for the repair of humeral diaphyseal fractures with proximal extension]]></article-title>
<source><![CDATA[Injury,]]></source>
<year>2019</year>
<volume>50</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>2247-51</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
