<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-2176</journal-id>
<journal-title><![CDATA[Revista Cubana de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Oftalmol]]></abbrev-journal-title>
<issn>0864-2176</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-21762005000200009</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[La tomografía de coherencia óptica en el diagnóstico de enfermedades de la retina y el nervio óptico]]></article-title>
<article-title xml:lang="en"><![CDATA[Optic coherence tomography in the diagnosis of the retina and optic nerve diseases]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mendoza Santiesteban]]></surname>
<given-names><![CDATA[Carlos E]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Santiesteban Freixas]]></surname>
<given-names><![CDATA[Rosaralis]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González García]]></surname>
<given-names><![CDATA[Alberto]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González Hess]]></surname>
<given-names><![CDATA[Luisa]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Perdomo Trujillo]]></surname>
<given-names><![CDATA[Yahumara]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Alemañy Rubio]]></surname>
<given-names><![CDATA[Ernesto]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Eguia]]></surname>
<given-names><![CDATA[Frank]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vidal Casalís]]></surname>
<given-names><![CDATA[Sergio]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto de Neurología y Neurocirugía  ]]></institution>
<addr-line><![CDATA[Ciudad de La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2005</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2005</year>
</pub-date>
<volume>18</volume>
<numero>2</numero>
<fpage>0</fpage>
<lpage>0</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762005000200009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-21762005000200009&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-21762005000200009&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El autor principal hace una exposición sobre los principales métodos imagenológicos en la oftalmología y sus fundamentos, en especial de la tomografía óptica coherente con el equipo Stratus 3000. Con su colectivo de autores presenta una galería de imágenes de la tomografía óptica coherente acompañadas de imágenes de fondo de ojo y los campos visuales, de más de 500 pacientes con diversas enfermedades de retina y nervio óptico, lo que constituye el primer atlas cubano sobre esta entidad]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The main author exposes the main imaging methods used in ophthalmology and their foundations, specially the optic coherence tomography with the Stratus 3000 equipment. Together with the other authors, he presents a gallery of images of the optic coherence tomography accompanied with images of the fundus oculi and the visual fields of more than 500 patients with different diseases of the retina and optic nerve, which constitute the first Cuban athlas on this entity]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Tomografía de coherencia óptica]]></kwd>
<kwd lng="es"><![CDATA[retina]]></kwd>
<kwd lng="es"><![CDATA[nervio óptico]]></kwd>
<kwd lng="en"><![CDATA[Optic coherence tomography exposure]]></kwd>
<kwd lng="en"><![CDATA[fundus oculi]]></kwd>
<kwd lng="en"><![CDATA[vidual fields]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <h3>Tema de revisi&oacute;n con presentaci&oacute;n en galer&iacute;a de im&aacute;genes    <br> </h3> <h2>La tomograf&iacute;a de coherencia &oacute;ptica en el diagn&oacute;stico    de enfermedades de la retina y el nervio &oacute;ptico    <br> </h2>     <p><a href="#cargo">Dr. Carlos E. Mendoza Santiesteban,<span class="superscript">1</span>    Dra. Rosaralis Santiesteban Freixas,<span class="superscript">2</span> Dr. Alberto    Gonz&aacute;lez Garc&iacute;a,<span class="superscript">3</span> Dra. Luisa    Gonz&aacute;lez Hess,<span class="superscript">3 </span>Dra. Yahumara Perdomo    Trujillo,<span class="superscript">4</span> Dr. Ernesto Alema&ntilde;y Rubio,<span class="superscript">3</span>    Dr. Frank Eguia<span class="superscript">3</span> y Sergio Vidal Casal&iacute;s<span class="superscript">3</span>    <br>   </a><a name="autor"></a> </p> <h4>Resumen    <br> </h4>     <p>El autor principal hace una exposici&oacute;n sobre los principales m&eacute;todos    imagenol&oacute;gicos en la oftalmolog&iacute;a y sus fundamentos, en especial    de la tomograf&iacute;a &oacute;ptica coherente con el equipo <i>Stratus</i>    3000. Con su colectivo de autores presenta una galer&iacute;a de im&aacute;genes    de la tomograf&iacute;a &oacute;ptica coherente acompa&ntilde;adas de im&aacute;genes    de fondo de ojo y los campos visuales, de m&aacute;s de 500 pacientes con diversas    enfermedades de retina y nervio &oacute;ptico, lo que constituye el primer atlas    cubano sobre esta entidad.</p>     <p><i>Palabras clave</i>: Tomograf&iacute;a de coherencia &oacute;ptica, retina;    nervio &oacute;ptico. </p>     <p>Sin duda alguna el desarrollo de las t&eacute;cnicas de exploraci&oacute;n    imagenol&oacute;gica ha constituido uno de los elementos de mayor desarrollo    en el diagn&oacute;stico m&eacute;dico en los &uacute;ltimos a&ntilde;os. T&eacute;cnicas    como la resonancia nuclear magn&eacute;tica, la tomograf&iacute;a axial computarizada,    la ultranosograf&iacute;a etc., han constituido herramientas revolucionarias    al permitir la visualizaci&oacute;n <i>in vivo</i> y de forma nada cruenta de    estructuras que escapan a los medios diagn&oacute;sticos tradicionales e incluso    a la imaginaci&oacute;n de los propios m&eacute;dicos.     <br> </p>     ]]></body>
<body><![CDATA[<p>Casi todas las especialidades se han beneficiado de estos avances y la oftalmolog&iacute;a    no ha estado al margen de tan vertiginoso desarrollo. La d&eacute;cada de los    90 signific&oacute; sin duda un periodo de desarrollo y perfeccionamiento de    los medios diagn&oacute;sticos en oftalmolog&iacute;a la que ha sido considerada    por algunos especialistas como la d&eacute;cada en la que se creci&oacute; el    equivalente a los 30 a&ntilde;os que la precedieron. Este avance, &iacute;ntimamente    relacionado al experimentado por la inform&aacute;tica, ha permitido revolucionar    campos tales como las im&aacute;genes del fondo de ojo, las t&eacute;cnicas    de angiograf&iacute;as retinales, el estudio del campo visual, la planificaci&oacute;n    y ejecuci&oacute;n de nuevas t&eacute;cnicas de cirug&iacute;a refractiva etc.    Este proceso ha posibilitado adem&aacute;s el surgimiento de nuevas herramientas    diagn&oacute;sticas como son las t&eacute;cnicas de tomograf&iacute;a computarizada    para el estudio de retina, el nervio &oacute;ptico y otras estructuras oculares.    <br> </p>     <p>Las t&eacute;cnicas de tomograf&iacute;a computarizada de retina y nervio &oacute;ptico    surgen con car&aacute;cter experimental en los a&ntilde;os 80 y alcanzan su    universo de aplicaciones cl&iacute;nicas en la d&eacute;cada del 90. A nivel    mundial son principalmente 3 los m&eacute;todos comercializados para este fin:    la tomograf&iacute;a confocal retinal fabricada por la casa <i>Heidelberg</i>    (Alemania) con los equipos comerciales HRT I y HRT II, la tomograf&iacute;a    por polarimetr&iacute;a de la firma <i>laser diagnostic technologies</i> (LDT)    con el equipo de nombre comercial <i>GDx</i>, y la tomograf&iacute;a de coherencia    &oacute;ptica (OCT) de la casa (<i>Carl Zeiss-Humphrey</i>) con el equipo comercializado    como OCT. Todos ellos realizan estudios tomogr&aacute;ficos bi y tri-dimensionales    de estructuras in vivo de la retina y el nervio &oacute;ptico lo que ha permitido    profundizar significativamente en el diagn&oacute;stico de las enfermedades    que afectan estos tejidos. El objetivo se esta revisi&oacute;n es dar a conocer    los principales equipos de estas t&eacute;cnicas de exploraci&oacute;n imagenol&oacute;gicas    de retina y nervio &oacute;ptico y mostrar algunas im&aacute;genes del OCT y    su correspondencia cl&iacute;nica con el fondo de ojo y el campo visual est&aacute;tico    de <i>Humphrey</i> en variadas entidades, lo que se exponen en im&aacute;genes    en la p&aacute;gina web de oftalmolog&iacute;a <a href="www.sld.cu/sitios/oftalmologia">www.sld.cu/sitios/oftalmologia</a>.    <br> </p> <h4>Desarrollo    <br> </h4>     <p>Con diferencias fundamentales en el tipo de l&aacute;ser que utilizan y en    el principio f&iacute;sico para la obtenci&oacute;n y an&aacute;lisis de las    se&ntilde;ales obtenidas, estos equipos han demostrado ampliamente su utilidad.        <br> </p>     <p>El <i>HRT </i>II usa un l&aacute;ser confocal que genera una serie de 16 a    64 planos de corte coronales con una profundidad axial de 4 mm. Construye excelentes    im&aacute;genes tridimensionales de la retina y el nervio &oacute;ptico pero    con una resoluci&oacute;n axial (resoluci&oacute;n en profundidad) de 300 &micro;m,    por lo que su mayor utilidad esta en el estudio morfom&eacute;trico del nervio    &oacute;ptico y la capa de fibras nerviosas (CFN). Para esta &uacute;ltima asume    un plano de referencia arbitrario de 50 &micro;m por debajo del borde superior    para establecer el borde inferior de CFN.     <br> </p>     <p>El GDx usa el principio de la birrefringencia de la CFN para su an&aacute;lisis,    pero a pesar de que logra resoluciones axiales en el orden de las 50&micro;m,    su uso se ve afectado por la interposici&oacute;n de otras estructuras oculares    birrefringentes como la c&oacute;rnea, el cristalino etc. que cambian de sujeto    a sujeto e hizo necesaria la correcci&oacute;n del equipo con compensadores    corneales variables. Por otra parte la polarimetr&iacute;a por GDx se ve afectada    significativamente despu&eacute;s de cirug&iacute;as refractivas por l&aacute;ser    (<i>Lasik, Lasek, Prk,</i> etc.), no obstante su uso esta tambi&eacute;n ampliamente    distribuido.     ]]></body>
<body><![CDATA[<br> </p>     <p>La OCT ha sido la &uacute;ltima de estas t&eacute;cnicas en aparecer, pero    su desarrollo, crecimiento y perfeccionamiento en los &uacute;ltimos 10 a&ntilde;os    la han convertido para muchos como la t&eacute;cnica tomogr&aacute;fica de elecci&oacute;n    para el estudio de la retina y el nervio &oacute;ptico al conseguir resolver    en los modelos m&aacute;s recientes im&aacute;genes de 1&micro;m de resoluci&oacute;n    axial.    <br> </p>     <p>Muestra del desarrollo de esta t&eacute;cnica es la monumental obra de Schuman    y otros recientemente publicada en su segunda edici&oacute;n<span class="superscript">1</span>    y m&uacute;ltiples trabajos que a diario aparecen sobre la utilidad de la OCT    en el estudio de diferentes entidades de la retina que por medios convencionales    no se lograba siempre un acertado diagn&oacute;stico y en especial en el estudio    de las capas de fibras ganglionares.<span class="superscript">2-16</span> Actualmente    se trabaja en modelos para estudios muy precisos del segmento anterior.    <br> </p>     <p>La tomograf&iacute;a de coherencia &oacute;ptica se desarrolla en la d&eacute;cada    del 80 en el <i>Massachusetts Institute of Technology</i> (MIT) de Boston, y    desde entonces han sido m&uacute;ltiples sus aplicaciones no s&oacute;lo en    el campo de la medicina sino en el de las ciencias en general. Dentro de la    medicina la oftalmolog&iacute;a ha sido el &aacute;rea de mayor desarrollo de    esta tecnolog&iacute;a, pero otras disciplinas tales como la cardiolog&iacute;a,    la gastroenterolog&iacute;a, las neurociencias etc, tambi&eacute;n han sido    beneficiadas con nuevos medios diagn&oacute;sticos al poder ser incorporados    sus dispositivos en endoscopios de casi todo tipo para la realizaci&oacute;n    de <i>biopsias &oacute;pticas</i> en tejidos sospechosos por patolog&iacute;as    m&uacute;ltiples.    <br> </p>     <p>Para muchos el OCT constituye una de las herramientas m&aacute;s revolucionarias    en el diagnostico oftalmol&oacute;gico de los &uacute;ltimos a&ntilde;os al    permitir la visualizaci&oacute;n, <i>in vivo</i> y sin contacto con el paciente,    de estructuras tisulares, s&oacute;lo vistas con anterioridad en cortes histol&oacute;gicos    de retinas de cad&aacute;ver, con una resoluci&oacute;n de alrededor de 8 &micro;m    (para el modelo comercial OCT3 o <i>Stratus</i> 3000).     <br> </p>     <p>Para los que por vez primera se acercan a estas im&aacute;genes resulta casi    incre&iacute;ble estar viendo entre 8 y 9 capas de la retina en cortes de profundidad    axial de alrededor de 2 mm, que incluyen las capas m&aacute;s internas de la    coroides, la retina y las estructuras v&iacute;treas posteriores. Los cortes    a nivel del nervio &oacute;ptico proporcionan im&aacute;genes de alto valor    acerca de la capa de fibras nerviosas (con detecci&oacute;n muy precisa de los    bordes anterior y posterior), la retina peripapilar y la morfolog&iacute;a del    disco &oacute;ptico, lo que posibilita el c&aacute;lculo de variables morfom&eacute;tricas    de alto valor diagn&oacute;stico. Las im&aacute;genes que sobre el segmento    anterior se obtienen incluyen; im&aacute;genes del espesor corneal y sus estructuras,    im&aacute;genes del &aacute;ngulo irido corneal, cara anterior del cristalino    etc.    ]]></body>
<body><![CDATA[<br> </p>     <p>A partir de la generaci&oacute;n del OCT3 estos tom&oacute;grafos se han dividido    en dos l&iacute;neas fundamentales; aquellos que brindan im&aacute;genes sobre    el polo posterior del globo ocular (retina, nervio &oacute;ptico, v&iacute;treo)    y los que las realizan sobre el segmento anterior (c&oacute;rnea, &aacute;ngulo    iridocorneal, cristalino etc). Tres generaciones de OCT han salido al mercado    desde el inicio de los a&ntilde;os de 1990. Hoy en d&iacute;a el OCT3 tiene    el nombre comercial <i>Stratus 3 000</i>, el equipo de mayor resoluci&oacute;n    disponible, aunque una nueva generaci&oacute;n (High Resolution OCT) est&aacute;    en fases de experimentaci&oacute;n cl&iacute;nica.     <br> </p>     <p>El principio b&aacute;sico de funcionamiento de esta tecnolog&iacute;a es la    interferometr&iacute;a de baja coherencia y ha sido comparado con prop&oacute;sitos    did&aacute;cticos, para su entendimiento por los oftalm&oacute;logos, a la ultrasonograf&iacute;a    ocular ampliamente conocida. Las im&aacute;genes bidimensionales del OCT, de    forma an&aacute;loga a las del modo <i>B</i> de ultrasonografia, se forman por    la suma de m&uacute;ltiples im&aacute;genes de modo <i>A</i> lineales denominadas    <i>A-scan </i>las cuales, en n&uacute;mero de 128 a 764, se unen para formar    una imagen bidimensional de barrido de OCT. Esta es precisamente una de las    fundamentales ventajas que esta tecnolog&iacute;a presenta sobre sus competidoras    al muestrear el mayor n&uacute;mero de puntos en profundidad (resoluci&oacute;n    axial) y permitir n&iacute;tidas im&aacute;genes del interior de los tejidos.    <br> </p>     <p>En la ilustraci&oacute;n siguiente se presenta un corte histol&oacute;gico    de retina en la regi&oacute;n macular y en un corte en ese mismo lugar con el    OCT 3. Casos ejemplos sobre la utilidad en el diagn&oacute;stico de diversas    entidades de retina y nervio &oacute;ptico, estudiados por los colaboradores,    son mostradas en la galer&iacute;a de im&aacute;genes sobre neuroftalmolog&iacute;a    y retina de la p&aacute;gina web <a href="www.sld.cu/sitios/oftalmolog%EDa">www.sld.cu/sitios/oftalmolog&iacute;a</a>    que incluye su correlato con el campo visual y la imagen de fondo de ojo, como    complemento de este trabajo (fig. 1). </p>     <p align="center"><a href="/img/revistas/oft/v18n2/f0109205.jpg"><img src="/img/revistas/oft/v18n2/f0109205.jpg" width="200" height="115" border="0"></a></p>     
<p align="center">Fig. 1. Tom&oacute;grafo de coherencia &oacute;ptica <i>Stratus-3000</i>.    Corte a nivel de m&aacute;cula.</p> <h4>Summary</h4> <h6>Optic coherence tomography in the diagnosis of the retina and optic nerve    diseases</h6>     <p>The main author exposes the main imaging methods used in ophthalmology and    their foundations, specially the optic coherence tomography with the Stratus    3000 equipment. Together with the other authors, he presents a gallery of images    of the optic coherence tomography accompanied with images of the fundus oculi    and the visual fields of more than 500 patients with different diseases of the    retina and optic nerve, which constitute the first Cuban athlas on this entity.</p>     <p><i>Key words</i>: Optic coherence tomography/exposure, fundus oculi, vidual    fields.</p>     ]]></body>
<body><![CDATA[<p></p> <h4>Referencias bibliogr&aacute;ficas    <br> </h4>     <!-- ref --><p> 1. Schuman JS, Puliafito CA,Fujimoto JG. Optical coherence tomography of ocular      diseases. 2.ed.USA Ed Slack Incorporated,2004.<!-- ref --><p> 2. Schenk JO, Brezinski ME. Ultrasound induced improvement in optical coherence      tomography (OCT) resolution. Proc Natl Acad Sci U S A. 2002; 99(15):9761-4.<!-- ref --><p> 3. Wojtkowski M, Leitgeb R, Kowalczyk A, Bajraszewski T, Fercher AF. In vivo      human retinal imaging by Fourier domain optical coherence tomography. J Biomed      Opt. 2002; 7(3):457-63.<!-- ref --><p> 4. Ophir A. Optical coherence tomography measurement of nerve fiber layer      thickness and the likelihood of a visual field defect. Am J Ophthalmol. 2003;      135(5):744-5.<!-- ref --><p> 5. Wakitani Y, Sasoh M, Sugimoto M, Ito Y, Ido M, Uji Y. Macular thickness      measurements in healthy subjects with different axial lengths using optical      coherence tomography. Retina. 2003; 23(2):177-82.<!-- ref --><p> 6. Kanamori A, Nakamura M, Escano MF, Seya R, Maeda H, Negi A. Evaluation      of the glaucomatous damage on retinal nerve fiber layer thickness measured      by optical coherence tomography. Am J Ophthalmol. 2003; 135(4):513-20.<!-- ref --><p> 7. Schuman JS, Wollstein G, Farra T, Hertzmark E, Aydin A, Fujimoto JG, Paunescu      LA. Comparison of optic nerve head measurements obtained by optical coherence      tomography and confocal scanning laser ophthalmoscopy. Am J Ophthalmol. 2003;      135(4):504-12.<p> 8. Medeiros FA, Moura FC, Vessani RM, Susanna R Jr. Axonal loss after traumatic      optic neuropathy documented by optical coherence tomography. Am J Ophthalmol.      2003; 135(3):406-8.</p>     ]]></body>
<body><![CDATA[<!-- ref --><p> 9. Ge J, Luo R, Guo Y. Corrective change of retinal thickness measured by      optical coherence tomography and histologic studies. Yan Ke Xue Bao. 1999;15(3):153-78.<!-- ref --><p> 10. Villain MA, Greenfield DS. Peripapillary nerve fiber layer thickness measurement      reproducibility using optical coherence tomography. Ophthalmic Surg Lasers      Imaging. 2003;34(1):33-7.<!-- ref --><p> 11. Mok KH, Lee VW, So KF. Retinal nerve fiber layer measurement by optical      coherence tomography in glaucoma suspects with short-wavelength perimetry      abnormalities. J Glaucoma. 2003; 12(1):45-9.<!-- ref --><p> 12. Furuichi M, Kashiwagi K, Tsukahara S. Variance between program versions      in measuring optic nerve fiber layer thickness using optical coherence tomography.      Ophthalmologica. 2002; 216(6):409-14.<!-- ref --><p> 13. Mok KH, Lee VW, So KF. Retinal nerve fiber layer measurement of the Hong      Kong Chinese population by optical coherence tomography. J Glaucoma. 2002;      11(6):481-3.<!-- ref --><p> 14. Carpineto P, Ciancaglini M, Zuppardi E, Falconio G, Doronzo E, Mastropasqua      L. Reliability of nerve fiber layer thickness measurements using optical coherence      tomography in normal and glaucomatous eyes. Ophthalmology. 2003; 110(1):190-5.<!-- ref --><p> 15. Guedes V, Schuman JS, Hertzmark E, Wollstein G, Correnti A, Mancini R,      Lederer D, Voskanian S, Velazquez L, Pakter HM, Pedut-Kloizman T, Fujimoto      JG, Mattox C. Optical coherence tomography measurement of macular and nerve      fiber layer thickness in normal and glaucomatous human eyes. Ophthalmology.      2003; 110(1):177-89.<!-- ref --><p> 16. Greenfield DS, Bagga H, Knighton RW. Macular thickness changes in glaucomatous      optic neuropathy detected using optical coherence tomography. Arch Ophthalmol.      2003; 121(1):41-6. <p>Recibido: 18 de agosto de 2005. Aprobado: 21 de octubre de 2005.    <br>   Dr. <i>Carlos E. Mendoza Santiesteban</i>. Instituto de Neurolog&iacute;a y    Neurocirug&iacute;a. Calle 29 No. 739 esquina a D, El Vedado, Ciudad de La Habana,    Cuba.    ]]></body>
<body><![CDATA[<br> </p>     <p><span class="superscript"><a href="#autor">1</a></span><a href="#autor">Especialista    I Grado en Neurofisiolog&iacute;a. Diplomado en Neurooftalmolog&iacute;a y Retina.        <br>   <span class="superscript">2</span>Doctora en Ciencias M&eacute;dicas. Especialista    de II Grado en Oftalmolog&iacute;a. Investigadora Titular y Profesora Auxiliar    y Consultante.     <br>   <span class="superscript">3</span> Especialista de I Grado en Oftalmolog&iacute;a    .    <br>   <span class="superscript">4</span>Licenciada en Tecnolog&iacute;a de la Salud    en la rama de Oftalmolog&iacute;a.</a><a name="cargo"></a>        ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schuman]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Puliafito]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Fujimoto]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
</person-group>
<source><![CDATA[Optical coherence tomography of ocular diseases]]></source>
<year>2004</year>
<edition>2</edition>
<publisher-name><![CDATA[Ed Slack Incorporated]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schenk]]></surname>
<given-names><![CDATA[JO]]></given-names>
</name>
<name>
<surname><![CDATA[Brezinski]]></surname>
<given-names><![CDATA[ME]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ultrasound induced improvement in optical coherence tomography (OCT) resolution]]></article-title>
<source><![CDATA[Proc Natl Acad Sci U S A]]></source>
<year>2002</year>
<volume>99</volume>
<numero>15</numero>
<issue>15</issue>
<page-range>9761-4</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wojtkowski]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Leitgeb]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kowalczyk]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bajraszewski]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Fercher]]></surname>
<given-names><![CDATA[AF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo human retinal imaging by Fourier domain optical coherence tomography]]></article-title>
<source><![CDATA[J Biomed Opt]]></source>
<year>2002</year>
<volume>7</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>457-63</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ophir]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optical coherence tomography measurement of nerve fiber layer thickness and the likelihood of a visual field defect]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2003</year>
<volume>135</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>744-5</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wakitani]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Sasoh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Sugimoto]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ito]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Ido]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Uji]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Macular thickness measurements in healthy subjects with different axial lengths using optical coherence tomography]]></article-title>
<source><![CDATA[Retina]]></source>
<year>2003</year>
<volume>23</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>177-82</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kanamori]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Nakamura]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Escano]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
<name>
<surname><![CDATA[Seya]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Maeda]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Negi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography]]></article-title>
<source><![CDATA[J Ophthalmol]]></source>
<year>2003</year>
<volume>135</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>513-20</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Schuman]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Wollstein]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Farra]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hertzmark]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Aydin]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fujimoto]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Paunescu]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of optic nerve head measurements obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2003</year>
<volume>135</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>504-12</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Medeiros]]></surname>
<given-names><![CDATA[FA]]></given-names>
</name>
<name>
<surname><![CDATA[Moura]]></surname>
<given-names><![CDATA[FC]]></given-names>
</name>
<name>
<surname><![CDATA[Vessani]]></surname>
<given-names><![CDATA[RM]]></given-names>
</name>
<name>
<surname><![CDATA[Susanna]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Axonal loss after traumatic optic neuropathy documented by optical coherence tomography]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2003</year>
<volume>135</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>406-8</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ge]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Luo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Guo]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corrective change of retinal thickness measured by optical coherence tomography and histologic studies]]></article-title>
<source><![CDATA[Yan Ke Xue Bao]]></source>
<year>1999</year>
<volume>15</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>153-78</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Villain]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Greenfield]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Peripapillary nerve fiber layer thickness measurement reproducibility using optical coherence tomography]]></article-title>
<source><![CDATA[Ophthalmic Surg Lasers Imaging]]></source>
<year>2003</year>
<volume>34</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>33-7</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mok]]></surname>
<given-names><![CDATA[KH]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[VW]]></given-names>
</name>
<name>
<surname><![CDATA[So]]></surname>
<given-names><![CDATA[KF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Retinal nerve fiber layer measurement by optical coherence tomography in glaucoma suspects with short-wavelength perimetry abnormalities]]></article-title>
<source><![CDATA[J Glaucoma]]></source>
<year>2003</year>
<volume>12</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>45-9</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Furuichi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kashiwagi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Tsukahara]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Variance between program versions in measuring optic nerve fiber layer thickness using optical coherence tomography]]></article-title>
<source><![CDATA[Ophthalmologica]]></source>
<year>2002</year>
<volume>216</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>409-14</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mok]]></surname>
<given-names><![CDATA[KH]]></given-names>
</name>
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[VW]]></given-names>
</name>
<name>
<surname><![CDATA[So]]></surname>
<given-names><![CDATA[KF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Retinal nerve fiber layer measurement of the Hong Kong Chinese population by optical coherence tomography]]></article-title>
<source><![CDATA[J Glaucoma]]></source>
<year>2002</year>
<volume>11</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>481-3</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carpineto]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ciancaglini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Zuppardi]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Falconio]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Doronzo]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Mastropasqua]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reliability of nerve fiber layer thickness measurements using optical coherence tomography in normal and glaucomatous eyes]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2003</year>
<volume>110</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>190-5</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guedes]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Schuman]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
<name>
<surname><![CDATA[Hertzmark]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Wollstein]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Correnti]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mancini]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Lederer]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Voskanian]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Velazquez]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Pakter]]></surname>
<given-names><![CDATA[HM]]></given-names>
</name>
<name>
<surname><![CDATA[Pedut-Kloizman]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Fujimoto]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Mattox]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2003</year>
<volume>110</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>177-89</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Greenfield]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
<name>
<surname><![CDATA[Bagga]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Knighton]]></surname>
<given-names><![CDATA[RW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Macular thickness changes in glaucomatous optic neuropathy detected using optical coherence tomography]]></article-title>
<source><![CDATA[Arch Ophthalmol]]></source>
<year>2003</year>
<volume>121</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>41-6</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>