<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-2176</journal-id>
<journal-title><![CDATA[Revista Cubana de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Oftalmol]]></abbrev-journal-title>
<issn>0864-2176</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-21762011000200001</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Cuantificación objetiva de la opacidad de la cápsula posterior mediante tomogramas Scheimpflug del Pentacam]]></article-title>
<article-title xml:lang="en"><![CDATA[Objective quantification of opacification of posterior capsule by using Scheimpflug Pentacam tomograms]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández López]]></surname>
<given-names><![CDATA[Iván]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Nuñez Larín]]></surname>
<given-names><![CDATA[Yisell]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fernández Hernández]]></surname>
<given-names><![CDATA[Yaquelin]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Veitía Rovirosa]]></surname>
<given-names><![CDATA[Zucell]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez Candelaria]]></surname>
<given-names><![CDATA[Eneida]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Padilla González]]></surname>
<given-names><![CDATA[Carmen]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Cubano de Oftalmología Ramón Pando Ferrer  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2011</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2011</year>
</pub-date>
<volume>24</volume>
<numero>2</numero>
<fpage>208</fpage>
<lpage>219</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762011000200001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-21762011000200001&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-21762011000200001&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Objetivo: Cuantificar objetivamente la opacidad de la cápsula posterior poscirugía de catarata con implante de lente intraocular mediante el uso de la cámara Scheimpflug del Pentacam y evaluar su correlación con la gradación subjetiva mediante lámpara de hendidura. Métodos: Se estudiaron 35 ojos operados de catarata por facoemulsificación en el Instituto Cubano de Oftalmología de marzo a septiembre de 2010. Se evaluó el grado opacidad capsular mediante examen por lámpara de hendidura y por análisis de tomogramas Scheimpflug con el software libre Image J. Finalmente se calculó la correlación entre ambos procederes. Resultados: El valor promedio de la intensidad de pixeles de los tomogramas del Pentacam resultó de 21,142 unidades. Existió correlación positiva significativa entre el grado de severidad de la opacidad de la cápsula posterior por lámpara de hendidura y la intensidad de pixeles de la opacidad de la cápsula posterior obtenida del análisis de los tomogramas del Pentacam. (p= 0,000; r= 0,961) Se observó una correlación negativa significativa entre la mejor agudeza visual corregida y ambos procedimientos. Conclusión: El análisis de tomogramas Scheimpflug permite obtener un indicador preciso y reproducible para la cuantificación objetiva de la opacidad de la cápsula posterior.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Objectives: To objectively quantify the posterior capsule opacification (PCO) after cataract surgery and intraocular lens implantation by analyzing Scheimpflug Pentacam tomograms and to evaluate its relation with the subjective gradation by using slit lamp exam. Methods: Thirty five eyes were studied after cataract surgery and intraocular lens implantation at Cuban Institute of Ophthalmology from March to September 2010. PCO was evaluated based on both slit lamp exam and Scheimpflug Images analysis. Correlation coefficients were calculated for both procedures. Results: Mean pixel-intensity value using Image J was 21.142. There was a significant positive correlation between PCO severity grade (P = 0.000; r = 0.961) by slit lamp gradation and PCO pixel intensity obtained from Pentacam tomograms analysis. A significant negative correlation was observed between best corrected visual acuity and both procedures. Conclusions: Scheimpflug tomograms analysis is an applicable method to obtain a factual and reliable indicator for PCO objective quantification.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Cirugía de catarata]]></kwd>
<kwd lng="es"><![CDATA[opacidad de cápsula posterior]]></kwd>
<kwd lng="es"><![CDATA[Pentacam]]></kwd>
<kwd lng="es"><![CDATA[cámara Scheimpflug]]></kwd>
<kwd lng="en"><![CDATA[Cataract surgery]]></kwd>
<kwd lng="en"><![CDATA[posterior capsule opacification]]></kwd>
<kwd lng="en"><![CDATA[Pentacam]]></kwd>
<kwd lng="en"><![CDATA[Scheimpflug]]></kwd>
<kwd lng="en"><![CDATA[Camera]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><strong><font size="2" face="Verdana, Arial, Helvetica, sans-serif">INVESTIGACIONES</font></strong></p>     <p align="right">&nbsp;</p>     <p><font size="4" face="Verdana, Arial, Helvetica, sans-serif"><strong>Cuantificaci&oacute;n    objetiva de la opacidad de la c&aacute;psula posterior mediante tomogramas Scheimpflug    del Pentacam</strong></font></p>     <p>&nbsp;</p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong> Objective    quantification of opacification of posterior capsule by using Scheimpflug Pentacam    tomograms</strong></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Dr. Iv&aacute;n    Hern&aacute;ndez L&oacute;pez, Dra. Yisell Nu&ntilde;ez Lar&iacute;n, Tec. Yaquelin    Fern&aacute;ndez Hern&aacute;ndez, Dra. Zucell Veit&iacute;a Rovirosa, Dra.    Eneida P&eacute;rez Candelaria, Dra. Carmen Padilla Gonz&aacute;lez</strong></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Instituto Cubano  de Oftalmolog&iacute;a &quot;Ram&oacute;n Pando Ferrer&quot;. La Habana, Cuba.</font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p> <hr noshade>     <p><strong><font size="2" face="Verdana, Arial, Helvetica, sans-serif">RESUMEN</font></strong></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Objetivo:</strong>    Cuantificar objetivamente la opacidad de la c&aacute;psula posterior poscirug&iacute;a    de catarata con implante de lente intraocular mediante el uso de la c&aacute;mara    Scheimpflug del Pentacam y evaluar su correlaci&oacute;n con la gradaci&oacute;n    subjetiva mediante l&aacute;mpara de hendidura.    <br>   <strong>M&eacute;todos:</strong> Se estudiaron 35 ojos operados de catarata    por facoemulsificaci&oacute;n en el Instituto Cubano de Oftalmolog&iacute;a    de marzo a septiembre de 2010. Se evalu&oacute; el grado opacidad capsular mediante    examen por l&aacute;mpara de hendidura y por an&aacute;lisis de tomogramas Scheimpflug    con el software libre Image J. Finalmente se calcul&oacute; la correlaci&oacute;n    entre ambos procederes.    <br>   <strong>Resultados:</strong> El valor promedio de la intensidad de pixeles de    los tomogramas del Pentacam result&oacute; de 21,142 unidades. Existi&oacute;    correlaci&oacute;n positiva significativa entre el grado de severidad de la    opacidad de la c&aacute;psula posterior por l&aacute;mpara de hendidura y la    intensidad de pixeles de la opacidad de la c&aacute;psula posterior obtenida    del an&aacute;lisis de los tomogramas del Pentacam. (p= 0,000; r= 0,961) Se    observ&oacute; una correlaci&oacute;n negativa significativa entre la mejor    agudeza visual corregida y ambos procedimientos.    <br>   <strong>Conclusi&oacute;n:</strong> El an&aacute;lisis de tomogramas Scheimpflug    permite obtener un indicador preciso y reproducible para la cuantificaci&oacute;n    objetiva de la opacidad de la c&aacute;psula posterior.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Palabras clave</strong>: Cirug&iacute;a de catarata, opacidad de c&aacute;psula    posterior, Pentacam, c&aacute;mara Scheimpflug.</font></p> <hr noshade>     <p><font size="2"><strong><font face="Verdana, Arial, Helvetica, sans-serif">ABSTRACT</font></strong></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Objectives:</strong>    To objectively quantify the posterior capsule opacification (PCO) after cataract    surgery and intraocular lens implantation by analyzing Scheimpflug Pentacam    tomograms and to evaluate its relation with the subjective gradation by using    slit lamp exam.     <br>   <strong>Methods</strong>: Thirty five eyes were studied after cataract surgery    and intraocular lens implantation at Cuban Institute of Ophthalmology from March    to September 2010. PCO was evaluated based on both slit lamp exam and Scheimpflug    Images analysis. Correlation coefficients were calculated for both procedures.        ]]></body>
<body><![CDATA[<br>   <strong>Results:</strong> Mean pixel-intensity value using Image J was 21.142.    There was a significant positive correlation between PCO severity grade (P =    0.000; r = 0.961) by slit lamp gradation and PCO pixel intensity obtained from    Pentacam tomograms analysis. A significant negative correlation was observed    between best corrected visual acuity and both procedures.    <br>   <strong>Conclusions:</strong> Scheimpflug tomograms analysis is an applicable    method to obtain a factual and reliable indicator for PCO objective quantification.  </font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Key words:</strong> Cataract surgery, posterior capsule opacification,    Pentacam, Scheimpflug Camera.</font></p> <hr noshade>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><strong><font size="3" face="Verdana, Arial, Helvetica, sans-serif">INTRODUCCI&Oacute;N</font></strong></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los avances en    la cirug&iacute;a de la catarata con implante de lente intraocular han hecho    posible una mejor&iacute;a manifiesta de los resultados visuales posoperatorios.    Esto ha logrado que los pacientes dependan cada vez menos de cristales correctores    despu&eacute;s de la cirug&iacute;a. No obstante, la opacidad de la c&aacute;psula    posterior contin&uacute;a siendo una de las complicaciones m&aacute;s frecuentes,    tras una cirug&iacute;a exitosa, que compromete de manera importante el resultado    visual obtenido.<sup>1</sup> Aunque la capsultom&iacute;a con Nd. YAG l&aacute;ser    se considera un m&eacute;todo efectivo para tratar la opacidad capsular, no    est&aacute; exenta de riesgos. Adem&aacute;s no siempre est&aacute; al alcance    de todos los pacientes y cuando estos son poco cooperativos para el correcto    posicionamiento de la cabeza, como los ni&ntilde;os peque&ntilde;os, no pueden  ser beneficiados con este proceder.<sup>2</sup></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Un an&aacute;lisis    lo m&aacute;s exacto posible de la opacidad de la c&aacute;psula posterior (OCP)    es de gran importancia para poder evaluar objetivamente, el efecto de las diferentes    intervenciones que actualmente se realizan para reducir su desarrollo.<sup>3</sup> Entre ellas el uso de m&uacute;ltiples sustancias farmacol&oacute;gicas,<sup>4-9</sup>    modificaciones en las t&eacute;cnicas quir&uacute;rgicas<sup>10-18</sup> y diferentes    lentes intraoculares en cuanto a composici&oacute;n y dise&ntilde;o.<sup>19-26</sup></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En los &uacute;ltimos    a&ntilde;os han surgido varios sistemas de im&aacute;genes. No obstante no existe    hasta el presente un consenso sobre cu&aacute;l es el mejor m&eacute;todo para    la cuantificaci&oacute;n objetiva de la OCP.<sup>27-30</sup></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El Pentacam es    un equipo oftalmol&oacute;gico de alta tecnolog&iacute;a capaz de reconstruir    im&aacute;genes tridimensionales de alta resoluci&oacute;n del polo anterior    del ojo. Esto lo realiza a partir de m&uacute;ltiples fotograf&iacute;as tomadas    mediante una c&aacute;mara rotacional del sistema Scheimpflug con que cuenta    el equipo. El an&aacute;lisis de estos tomogramas en 3D puede potencialmente    ser utilizado para la cuantificaci&oacute;n objetiva de la OCP.<sup>30</sup>    El primer sistema Scheimpflug solo capturaba im&aacute;genes en un solo meridiano.    Este sistema fue desarrollado m&aacute;s adelante por Hayashi y colaboradores    en 1998, logrando analizar im&aacute;genes obtenidas en 4 meridianos. A este    doctor se deben los primeros trabajos reportados sobre el uso de las im&aacute;genes    de Scheimpflug para cuantificar la OCP en ese a&ntilde;o.<sup>31-34</sup></font></p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El moderno sistema    Scheimpflug con que cuenta el Pentacam es capaz de capturar im&aacute;genes    en m&uacute;ltiples meridianos (hasta 50 im&aacute;genes en 2 segundos) en un    &uacute;nico escaneo automatizado. Posteriormente, calcula un modelo tridimensional    del segmento anterior del ojo a partir de los 25 000 puntos de elevaci&oacute;n    real.<sup>30</sup> El equipo permite adem&aacute;s aislar espec&iacute;ficamente    la estructura deseada de la imagen tomogr&aacute;fica, en este caso el saco    capsular, para ser analizada posteriormente.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los tomogramas    del Pentacam tienen adem&aacute;s la ventaja de no presentar destellos de luz    que interfieran con el an&aacute;lisis. Esto s&iacute; sucede con las fotograf&iacute;as    en retroiluminaci&oacute;n tomadas por los sistemas de adquisici&oacute;n de    im&aacute;genes en l&aacute;mpara de hendidura, en que basan su an&aacute;lisis    otros programas de evaluaci&oacute;n de la opacidad de c&aacute;psula posterior.<sup>3,27-29</sup></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El objetivo de    este estudio es cuantificar de manera objetiva, estandarizada, confiable y    reproducible, mediante el an&aacute;lisis de tomogramas del Pentacam,  la OCP. Una vez logrado permita evaluar la eficacia de las m&uacute;ltiples    intervenciones que actualmente se investigan para reducir su incidencia.</font></p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>M&Eacute;TODOS</strong></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se realiz&oacute;    un estudio observacional, descriptivo y prospectivo en 35 pacientes. Estos fueron operados de catarata con implante de lente intraocular    en el Instituto Cubano de Oftalmolog&iacute;a &#8220;Ram&oacute;n Pando Ferrer&#8221;    en el periodo comprendido entre marzo y septiembre de 2010.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Las variables estudiadas    fueron: grado subjetivo de OCP, &iacute;ndice objetivo de OCP y mejor agudeza    visual corregida (MAVC). La evaluaci&oacute;n de la OCP se realiz&oacute; a    los 3 meses de la cirug&iacute;a en todos aquellos pacientes que no presentaran    comorbilidad ocular que influyera negativamente en la agudeza visual y que expresaron    por escrito su acuerdo manifiesto de participar en el estudio.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A todos los pacientes    se les tom&oacute; la MAVC y se les realiz&oacute;, previa midriasis, un an&aacute;lisis    subjetivo del grado de severidad de la OCP mediante el examen en la l&aacute;mpara    de hendidura. Se clasific&oacute; en: grado 0 (no opacidad), grado 1 (leve),    grado 2 (moderada) y grado 3 (severa). Posteriormente a cada paciente se le    tomaron m&uacute;ltiples im&aacute;genes del ojo estudiado (50 im&aacute;genes    en 2 segundos) mediante la c&aacute;mara Scheimpflug del Pentacam y se obtuvo    tomogramas en 3 D de alta resoluci&oacute;n del segmento anterior de cada ojo.    Se eliminaron del modelo tridimensional las estructuras no necesarias para el    an&aacute;lisis, aislando selectivamente el saco capsular. Este fue llevado    desde la vista en perspectiva (vista predeterminada del Pentacam) a una vista    anteroposterior similar a la que vemos en una l&aacute;mpara de hendidura (<a href="#f1">Fig. 1</a>). Las im&aacute;genes se guardaron en formato JPEG. </font></p>     <p align="center"><a name="f1"></a><img src="/img/revistas/oft/v24n2/f0101211.jpg" alt="f1" width="580" height="360"></p>     
<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Estas im&aacute;genes    fueron analizadas mediante el software Image J 1.42q desarrollado por el <em>National    Institute of Health</em> de Estados Unidos y descargado libremente desde su    <a href="http://rsb.info.nih.gov/ij/" target="_blank">sitio web</a>. Basados en los c&aacute;lculos    realizados por Grewal y otros que determinaron que para los tomogramas del Pentacam    un &aacute;rea de 4 mm corresponden a 16 752 pixeles en la imagen;<sup>30</sup>    calculamos que una selecci&oacute;n circular de 12 645 p&iacute;xeles correspond&iacute;a    a un &aacute;rea de 3 mm. Este fue el di&aacute;metro de c&aacute;psula posterior    seleccionado para ser analizado en nuestro estudio. Esta selecci&oacute;n fue    salvada con la herramienta <em>ROI manager</em> para ser utilizada invariablemente    en todas las im&aacute;genes. Finalmente, se utilizaron las herramientas<em>    Find Edges</em> (hallar bordes) y <em>Measure</em> (medici&oacute;n) para calcular    el valor promedio de la intensidad de pixeles del &aacute;rea seleccionada en    los tomogramas Scheimpflug, como indicador cuantitativo equivalente a la densidad    de la opacidad capsular posterior, expresado en unidades (U) (<a href="#f2">Fig. 2</a>). Para    determinar la repetitividad del indicador se hicieron dos an&aacute;lisis diferentes    de cada una de los tomogramas con el Image J por el mismo observador para ser    comparados.</font></p>     <p align="center"><a name="f2"></a><img src="/img/revistas/oft/v24n2/f0201211.jpg" alt="f2" width="420" height="405"></p>     
]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La informaci&oacute;n    obtenida fue tabulada mediante el uso del programa Microsoft Office Excel 2007.    Para el an&aacute;lisis estad&iacute;stico se utiliz&oacute; el software SPSS    11.5.1 para Windows. Se utiliz&oacute; el coeficiente de Spearman para establecer    la correlaci&oacute;n entre el an&aacute;lisis de los tomogramas por el Image    J y la gradaci&oacute;n por l&aacute;mpara de hendidura; as&iacute; como para    la correlaci&oacute;n entre este &uacute;ltimo m&eacute;todo y la MAVC. La correlaci&oacute;n    entre el indicador obtenido por el Image J y la MAVC se estableci&oacute; mediante    el coeficiente de Pearson. La repetitividad del indicador obtenido se analiz&oacute;    mediante la obtenci&oacute;n del valor promedio de variaci&oacute;n entre las    diferentes tomas realizadas con 95 % de intervalo de confianza.</font></p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>RESULTADOS</strong></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La edad promedio    de los pacientes que al examen con l&aacute;mpara de hendidura no presentaban    opacidad capsular (grado 0) fue de 70,5 a&ntilde;os (rango, 61-88 a&ntilde;os),    mientras que aquellos con opacidad leve (grado 1) fue de 70 a&ntilde;os (rango,    59-88 a&ntilde;os). En los pacientes con opacidad moderada (grado 2) y severa    (grado 3) la edad promedio fue de 71 a&ntilde;os (rango, 49-85 a&ntilde;os)    y 67,7 a&ntilde;os (rango 58-84 a&ntilde;os) respectivamente.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Para los pacientes    con opacidades grados 0 y 1 seg&uacute;n l&aacute;mpara de hendidura, el valor    promedio de la intensidad de pixeles (indicador equivalente a la densidad de    la OCP) calculado por el programa Image J fue de 4 201 y 13 910 U respectivamente.    Para el grupo con opacidad grado 2 la media de este indicador fue de 26 455    U y para el grado 3 de 54 608 U. Existieron diferencias significativas entre    cada grado de severidad (p= 0.000) (<a href="#f3">Fig. 3</a>)</font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">.</font></p>     <p align="center"><a name="f3"></a><img src="/img/revistas/oft/v24n2/f0301211.jpg" alt="f3" width="463" height="495"></p>     
<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se demostr&oacute;    una correlaci&oacute;n positiva significativa entre el grado de severidad de    la OCP por l&aacute;mpara de hendidura y la intensidad de pixeles de la OCP    obtenida del an&aacute;lisis de los tomogramas del Pentacam (coeficiente de    correlaci&oacute;n de Spearman: R= 0,961; p= 0,000) (<a href="#f4">Fig. 4</a>).</font></p>     <p align="center"><a name="f4"></a><img src="/img/revistas/oft/v24n2/f0401211.jpg" alt="f4" width="426" height="349"></p>     
<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">As&iacute; mismo    el an&aacute;lisis de la intensidad de pixeles de los tomogramas Scheimpfug    por medio del programa Image J demostr&oacute; una muy buena repetitividad.    Esto fue al comparar entre 2 diferentes c&aacute;lculos llevados a cabo por    un mismo observador a cada uno de los ojos estudiados (R2= 0,997) (<a href="#f5">Fig. 5</a>).</font></p>     <p align="center"><a name="f5"></a><img src="/img/revistas/oft/v24n2/f0501211.jpg" alt="f5" width="417" height="305"></p>     
<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Esta repetitividad    se corrobor&oacute; mediante la obtenci&oacute;n del valor promedio de variaci&oacute;n    entre ambos c&aacute;lculos que result&oacute; ser de 0,16594 (intervalo de    confianza para la media al 95 %). Present&oacute; proporcionalidad directa al    grado de OCP por l&aacute;mpara de hendidura (<a href="#t1">tabla 1</a>).</font></p>     ]]></body>
<body><![CDATA[<p align="center"><a name="t1"></a><img src="/img/revistas/oft/v24n2/t0101211.gif" alt="t1" width="426" height="284"></p>     
<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Por otra parte,    la MAVC mostr&oacute; una correlaci&oacute;n negativa estad&iacute;sticamente    significativa con respecto a la gradaci&oacute;n por l&aacute;mpara de hendidura    (coeficiente de correlaci&oacute;n de Spearman: R= -0,612; p= 0,00). Tambi&eacute;n    con el &iacute;ndice de OCP calculado con Image J (coeficiente de correlaci&oacute;n    de Pearson R= -0,676; p= 0,00) (<a href="#t2">tabla 2</a>)</font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">. </font></p>     <p align="center"><a name="t2"></a><img src="/img/revistas/oft/v24n2/t0201211.gif" alt="t2" width="418" height="198"></p>     
<p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>DISCUSI&Oacute;N</strong></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Este    estudio demostr&oacute; que mediante el an&aacute;lisis de tomogramas Scheimpflug    del Pentacam se obtuvo un indicador num&eacute;rico exacto. Esto permiti&oacute;    determinar la cuant&iacute;a precisa de la opacidad manteniendo correspondencia    con lo observado al examen biomicrosc&oacute;pico, pero eliminando la inexactitud    de la gradaci&oacute;n subjetiva de la OCP por medio de la l&aacute;mpara de    hendidura.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La correlaci&oacute;n    positiva estad&iacute;sticamente significativa demostrada, entre el resultado    del c&aacute;lculo del valor promedio de la intensidad de pixeles de los tomogramas    obtenidos por el sistema Scheimpflug del Pentacam y el grado de severidad observado    al examen de la l&aacute;mpara de hendidura coincide con estudios similares.<sup>27-30</sup>    Adem&aacute;s, <em>Saika </em>y otros demostraron que las im&aacute;genes de    la OCP obtenidas por el sistema Scheimpflug se correspondieron con los hallazgos    histol&oacute;gicos hallados en ojos de conejos.<sup>35</sup></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Aunque se han desarrollado    otros sistemas con los que se obtienen indicadores num&eacute;ricos para la    cuantificaci&oacute;n objetiva de la OCP como el EPCO, POCO, POCOman, AQUA y    OSCA;<sup>27-30,36</sup> todos se basan en el an&aacute;lisis de im&aacute;genes    en retroiluminaci&oacute;n obtenidas por l&aacute;mpara de hendidura. Estos    se ven afectados por reflejos luminosos (im&aacute;genes de Purkinje) que interfieren    con la imagen, por lo que se han visto precisados a desarrollar algoritmos para    su eliminaci&oacute;n haciendo m&aacute;s engorroso el proceso de an&aacute;lisis.<sup>29</sup>    Adem&aacute;s, la obtenci&oacute;n de la imagen con la calidad deseada puede    variar seg&uacute;n el sistema de adquisici&oacute;n empleado y la experiencia    del operador pues necesita una curva aprendizaje. Otro aspecto que disminuye    la objetividad de estos sistemas es que necesitan a&uacute;n de la intervenci&oacute;n    directa del hombre en varios pasos del an&aacute;lisis.<sup>3,27</sup></font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En cambio, las    im&aacute;genes Scheimpflug son adquiridas de forma muy r&aacute;pida independientemente    del operador al usar el modo de disparo autom&aacute;tico. Los tomogramas son    generados totalmente por el equipo con una alta resoluci&oacute;n siendo im&aacute;genes    que tienen las ventajas de tener un color de fondo azul constante y estar libres    de reflejos que interfieran con su an&aacute;lisis (<a href="#f1">Fig 1</a>). En cuanto al an&aacute;lisis    por el programa Image J, la selecci&oacute;n del &aacute;rea a analizar es el    &uacute;nico paso que puede variar al tener el operador la libertad de colocarlo    manualmente, aunque su di&aacute;metro s&iacute; puede ser predeterminado (<a href="#f2">Fig. 2</a>).  El alto grado de repetitividad obtenido al analizar m&aacute;s de una vez    cada tomograma de nuestro estudio corrobora la fiabilidad del proceder y la    m&iacute;nima posibilidad de sesgos intraobservador.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La toma de la agudeza    visual no es un par&aacute;metro fiable para medir la OCP porque puede afectarse    por la presencia de comorbilidad ocular, la cooperaci&oacute;n del paciente    y la experiencia del optometrista entre otros factores que conllevan sesgos    en su medici&oacute;n. No obstante, en este estudio se excluyeron aquellos con    afecciones oculares preoperatorias y la MAVC se comport&oacute; con una correlaci&oacute;n    negativa significativa entre ella y ambos m&eacute;todos de an&aacute;lisis    de la OCP. Fue menor a mayor opacidad capsular posterior como cabr&iacute;a    esperar.</font></p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los resultados    del presente trabajo nos permiten concluir que el an&aacute;lisis de los tomogramas    obtenidos con el sistema Scheimpflug del Pentacam constituye un m&eacute;todo    fiable que permite obtener un indicador exacto y reproducible para la cuantificaci&oacute;n    objetiva de la OCP. Su importancia radica en que puede ser utilizado como par&aacute;metro    est&aacute;ndar para expresar la densidad de la opacidad, haciendo mucho m&aacute;s    comparable los resultados de las m&uacute;ltiples intervenciones que actualmente    se investigan para reducir su incidencia.</font></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>REFERENCIAS    BIBLIOGR&Aacute;FICAS</strong></font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">1. Hern&aacute;ndez    L&oacute;pez I, Castro Gonz&aacute;lez Y, Trujillo Fonseca K, Cepero Hern&aacute;ndez    L, Miranda Hern&aacute;ndez I. Opacidad de la c&aacute;psula posterior. En:    Rio Torres M. Oftalmolog&iacute;a. Criterios y tendencias actuales. La Habana:  Ciencias M&eacute;dicas; 2009. p. 307-17.    </font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 2. American Academy    of Ophthalmology. Part XI. Cap. 9: Complications of cataract surgery. En su:    Lens and cataract. USA: American Academy of Ophthalmology; 2009. p. 182-6.    (Basic and Clinical Science Course; 11)</font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 3. Aslam TM, Dhillon    B, Werghi N, Taguri A, Wadood A. Systems of analysis of posterior capsule opacification.    Br J Ophthalmol. 2002 October;86(10). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1771330/" target="_blank">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1771330/</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">4. Chandler HL,    Barden CA, Lu P, Kusewitt DF, Colitz MH. Prevention of posterior capsule opacification    trough cycloxygenase-2 inhibition. Molecular vision. 2007;13.    Disponible en: <a href="http://www.molvis.org/molvis/v13/a74/" target="_blank">http://www.molvis.org/molvis/v    13/a74/</a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">5. Jonhede S, Petersen A,    Zetterberg M, Karlsson JO. Acute effects of the sigma-2 receptor agonist siramesine    on lysosomal and extra-lysosomal proteolytic systems in lens epithelial cells.    Mol Vis. 2010;16. Disponible en:<a href="http://www.molvis.org/molvis/v16/a92/" target="_blank">    http://www.molvis.org/molvis/v16/a92/ </a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">6. Tanaka S, Sumioka T,    Fujita N, Kitano A, Okada Y, Yamanaka O, et al. Suppression of injury-induced    epithelial-mesenchymal transition in a mouse lens epithelium lacking tenascin-C.    Molecular Vision. 2010;16. Disponible en:<a href="http://www.molvis.org/molvis/v16/a133/" target="_blank">    http://www.molvis.org/molvis/v16/a133/</a> </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">7. Weidmann A, Kwittner    S, Beck R, Teller J, Jonas L, Nebe JB. Prevention of Lens Epithelial Cell Growth    In Vitro Using Mibefradil-Containing PLGA Micro Particles. Open Ophthalmol J.    2008;2. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694602/" target="_blank">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2694602/</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">8. Awasthi N, Wang-Su ST,    Wagner BJ. Downregulation of MMP-2 and -9 by Proteasome Inhibition: A Possible    Mechanism to Decrease LEC Migration and Prevent Posterior Capsular Opacification.    Invest Ophthalmol Vis Sci. 2008 May;49(5). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2532066/" target="_blank">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2532066/    </a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">9. Portes AL, Almeida AC,    Allodi S, Monteiro ML, Miguel NC. Trypan blue staining for capsulorhexis: Ultrastructural    effect on lens epithelial cells and capsules. J Cataract Refract Surg. 2010;36(4). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/20362849" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/20362849</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">10. Leysen I, Coeckelbergh    T, Gobin L, Smet H, Daniel Y, De Groot V, et al. Cumulative neodimiun Yag laser    rates after bag-in-the-lens and lens-in-the-bag intraocular lens implantation:    comparative study. J Cataract Refract Surg. 2006;32(12). Disponible    en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/17137988" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/17137988    </a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">11. Sacu S, Menapace R,    Wirtitsch M, Buehl W, Rainer G, Findl O. Effect of anterior capsule polishing    on fibrotic capsule opacification: Three-year results. J Cataract Refract Surg.    2004;30(11). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/15519082" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/15519082</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">12. Sacu S, Menapace R,    Findl O, Georgopoulos M, Buehl W, Kriechbaum K, et al. Influence of optic edge    design and anterior capsule polishing on posterior capsule fibrosis. J Cataract    Refract Surg. 2004;30(3). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/15050264" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/15050264</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">13. Bolz M, Menapace R,    Findl O, Sacu S, Buehl W, Wirtitsch M, et al. Effect of anterior capsule polishing    on the posterior capsule opacification-inhibiting properties of a sharp-edged,    3-piece, silicone intraocular lens. Three- and 5-year results of a randomized    trial. J Cataract Refract Surg. 2006;32(9). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/16931265" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/16931265</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">14. Menapace R, Wirtitsch    M, Findl O, Buehl W, Kriechbaum K, Sacu S. Effect of anterior capsule polishing    on posterior capsule opacification and neodimium:YAG capsulotomy rates: Three-year    randomized trial. J Cataract Refract Surg. 2005;31(11). Disponible    en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/16412917" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/16412917</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">15. Zurresh KP, Apple DJ,    McAvoy J, Maloof AJ, Milverton EJ. Posterior capsule opacification (After cataract):    Surgical and implant related factors for prevention. En: Jitendar PV. Matering    the Arts of Bimanual microincision Phaco (Phaconit/MICS). New Delhi: Jaypee    Brothers; 2005. p. 396-420.    </font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">16. Tassignon MJ, Van Looveren    J. Bag-in-the-lens IOL implantation and pseudophakic retinal detachment. En:    Garg A, Ali&oacute; JL. Mastering phaco chop techniques. New Delhi: Jaypee Brothers;    2009. p. 213-5.    </font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">17. Chen MS, Ye YJ, Wang    Y, Liu Y, Wu L, Luo WX. Posterior continuous curvilinear capsulorhexis and optic    capture of the posterior chamber intraocular lens in pediatric cataract surgery.    Zhonghua Yan Ke Za Zhi. 2006 May;42(5). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/16762232" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/16762232</a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">18. Menapace R. Erradication    of after-cataract by posterior capsulorhexis and optic buttonholing combined    with anterior capsule polishing: A report of 1000 cases. En: Garg A, Fine H.    Mastering the techniques of advanced phaco surgery. New Delhi: Jaypee Brothers;    2008. p. 394-401.     </font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">19. Yuen C, Williams R,    Batterbury M, Grierson I. Modification of the surface properties of a lens material    to influence posterior capsular opacification. Clinical and Experimental Ophthalmology.    2006;34(6):568&#8211;74. Disponible en:<a href="http://onlinelibrary.wiley.com/doi/10.1111/j.1442-9071.2006.01278.x/full" target="_blank">    http://onlinelibrary.wiley.com/doi/10.1111/j.1442-9071.2006.01278.x/full </a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">20. Wegner L. Biocompatibility    of intraocular lens materials. Current opinion in Ophthalmology. 2008;19. Disponible en: <a href="http://bme.yonsei.ac.kr/community/data/Biocompatibilityofintraocularlensmaterials.pdf" target="_blank">http://bme.yonsei.ac.kr/community/data/Biocompatibilityofintraocularlensmaterials.pdf  </a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">  21. &#142;emaitiene R, Ja&#353;inskas V, Barzd&#158;iukas V, Auffarth GU. Prevention    of posterior capsule opacification using different intraocular lenses (results    of one-year clinical study). Medicina (Kaunas). 2004;40(8). Disponible    en: <a href="http://medicina.kmu.lt/0408/0408-04e.pdf" target="_blank">http://medicina.kmu.lt/0408/0408-04e.pdf</a>  </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">22. Flores Gait&aacute;n    A, Morales G&oacute;mez ME, Matiz H, Garz&oacute;n M. Opacidad de la c&aacute;psula    posterior despu&eacute;s de facoemulsificaci&oacute;n. Evaluaci&oacute;n de    varios tipos de lentes intraoculares. Rev Mex Oftalmol. Mayo-Junio 2005;79(3). Disponible en: <a href="http://www.medigraphic.com/pdfs/revmexoft/rmo-2005/rmo053f.pdf" target="_blank">http://www.medigraphic.com/pdfs/revmexoft/rmo-2005/rmo053f.pdf</a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 23. Katayama Y, Kobayakawa    S, Yanagawa H, Tochikubo T. The relationship between the adhesion characteristics    of acrylic intraocular lens materials and posterior capsule opacification. Ophthalmic    Res. 2007;39(5):. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/17851268" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/17851268</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">24. Buehl W, Findl O. Advances    in optic designs to reduce PCO. En: Garg A, Fine H. Mastering the techniques    of advance phaco surgery. New Delhi: Jaypee Brothers; 2008. p. 408-13.    </font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> 25. Nishi O, Nishi K, Sakanishi    K. Inhibition of migrating lens epithelial cells at the capsular bend created    by the rectangular optic edge of a posterior chamber intraocular lens. Ophthalmic    Surg Lasers. 1998;29(7) Disponible en:<a href="http://www.ncbi.nlm.nih.gov/pubmed/9674010" target="_blank">    http://www.ncbi.nlm.nih.gov/pubmed/9674010</a> </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">26. Boyce JF, Bhermi GS,    Spalton DJ, El-Osta AR. Mathematical modeling of the forces between an intraocular    lens and the capsule. J Cataract Refract Surg. 2002;28(10). Disponible    en: <a href="http://www.jcrsjournal.org/article/S0886-3350%2802%2901490-6/abstract" target="_blank">http://www.jcrsjournal.org/article/S0886-3350%2802%2901490-6/abstract</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">27. Findl O, Buehl W, Menapace    R, Georgopoulos M, Rainer G, Siegl H, et al. Comparison of 4 methods for quantifying    posterior capsule opacification. J Cataract Refract Surg. 2003 Jan;29(1). Disponible en: <a href="http://www.jcrsjournal.org/article/S0886-3350(02)01509-2/fulltext" target="_blank">http://www.jcrsjournal.org/article/S0886-3350%2802%2901509-2/fulltext</a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">28. Bender L, Spalton DJ,    Uyanonvara B, Boyce, C Heatley, Jose R, et al. POCOman: New system for quantifying    posterior capsule opacification. J Cataract Refract Surg. 2004;30(10). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/15474814" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/15474814</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">29. Findl O, Buehl W, Siegl    H, Pinz A. Removal of Reflections in the Photographic Assessmentof PCO by Fusion    of Digital Retroillumination Images. IOVS. Jan 2003;44(1). Disponible    en: <a href="http://www.iovs.org/content/44/1/275.long" target="_blank">http://www.iovs.org/content/44/1/275.long</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">30. Grewal D, Jain R, Brar    GS, Grewal SPS, Singh SP. Pentacam tomograms: A Novel Method for Quantification    of Posterior Capsule Opacification. IOVS. 2008;49(5). Disponible    en: <a href="http://www.iovs.org/content/49/5/2004.long" target="_blank">http://www.iovs.org/content/49/5/2004.long</a>    </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">31. Oliver Findl, Wolf Buehl,    Peter Bauer, Thomas Sycha. Intervenciones para la prevenci&oacute;n de la opacificaci&oacute;n    de la c&aacute;psula posterior (Revision Cochrane traducida). En: Biblioteca    Cochrane Plus 2010 N&uacute;mero 2. Oxford: Update Software Ltd.     (Traducida de The Cochrane Library, 2010 Issue 2 Art no. CD003738. Chichester,    UK: John Wiley &amp; Sons, Ltd.    ).</font></p>     <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">32. Hayashi K, Hayash H,    Nakao F, Hayashi F. In vivo quantitative measurement of posterior capsule opacification    after extracapsular cataract surgery. Am J Ophthalmol. 1998;125(6). Dsiponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed?term=.Invivoquantitativemeasurementofposteriorcapsuleopacificationafterextracapsularcataractsurgery" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed?term=.Invivoquantitativemeasurementofposteriorcapsuleopacificationafterextracapsularcataractsurgery</a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">33. Hayashi H,    Hayashi K, Nakao F, Hayashi F. Quantitative comparison of posterior capsule    opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular    lens implantation. Arch Ophthalmol. 1998;116(12). Dsiponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed?term=Quantitativecomparisonofposteriorcapsuleopacificationafterpolymethylmethacrylate%2Csilicone%2Candsoftacrylicintraocularlensimplantation" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed?term=Quantitativecomparisonofposterior    capsuleopacificationafterpolymethylmethacrylate%2Csilicone%2Candsoftacrylicintraocularlensimplantation    </a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">34. Hayashi K, Hayashi H,    Nakao F, Hayashi F. Reproducibility of posterior capsule opacification measurement    using Scheimpflug videophotography. J Cataract Refract Surg. 1998;24(12). Dsiponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed?term=ReproducibilityofposteriorcapsuleopacificationmeasurementusingScheimpflugvideophotography" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed?term=ReproducibilityofposteriorcapsuleopacificationmeasurementusingScheimpflugvideophotography    </a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">35. Saika S, Miyamoto T,    Ishida I, Tanaka T, Okada Y, Nagane Y, et al. Comparison of Scheimpflug images    of posterior capsule opacification and histological findings in rabbits and    humans. J Cataract Refract Surg. 2001;27(7). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/11489581" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/11489581    </a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">36. Aslam TM, Patton N,    Rose CJ. OSCA: a comprehensive open-access system of analysis of posterior capsular    opacification. BMC Ophthalmol. 2006 ;6(30). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1592309/?tool=pubmed" target="_blank">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC1592309/?tool=pubmed</a></font><p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Recibido:20 de febrero de 2011.     <br>   Aprobado: 21 de marzo de 2011. </font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Dr. <em>Iv&aacute;n    Hern&aacute;ndez L&oacute;pez</em>. Instituto Cubano de Oftalmolog&iacute;a    &#8220;Ram&oacute;n Pando Ferrer&#8221;. Ave. 76 No. 3104 entre 31 y 41 Marianao.    La Habana, Cuba. Correo electr&oacute;nico: <a href="mailto:ivan.hdez@infomed.sld.cu">ivan.hdez@infomed.sld.cu</a></font><font size="2">    </font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández López]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Castro González]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Trujillo Fonseca]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Cepero Hernández]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Miranda Hernández]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Opacidad de la cápsula posterior]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Rio Torres]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Oftalmología: Criterios y tendencias actuales]]></source>
<year>2009</year>
<page-range>p. 307-17</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Ciencias Médicas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<collab>American Academy of Ophthalmology</collab>
<article-title xml:lang="en"><![CDATA[Part XI: Cap. 9: Complications of cataract surgery]]></article-title>
<source><![CDATA[Lens and cataract]]></source>
<year>2009</year>
<page-range>p. 182-6</page-range><publisher-loc><![CDATA[^eUSA USA]]></publisher-loc>
<publisher-name><![CDATA[American Academy of Ophthalmology]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aslam]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
<name>
<surname><![CDATA[Dhillon]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Werghi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Taguri]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wadood]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Systems of analysis of posterior capsule opacification]]></article-title>
<source><![CDATA[Br J Ophthalmol]]></source>
<year>2002</year>
<month> O</month>
<day>ct</day>
<volume>86</volume>
<numero>10</numero>
<issue>10</issue>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chandler]]></surname>
<given-names><![CDATA[HL]]></given-names>
</name>
<name>
<surname><![CDATA[Barden]]></surname>
<given-names><![CDATA[CA]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kusewitt]]></surname>
<given-names><![CDATA[DF]]></given-names>
</name>
<name>
<surname><![CDATA[Colitz]]></surname>
<given-names><![CDATA[MH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevention of posterior capsule opacification trough cycloxygenase-2 inhibition]]></article-title>
<source><![CDATA[Molecular vision]]></source>
<year>2007</year>
<volume>13</volume>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jonhede]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Petersen]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Zetterberg]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Karlsson]]></surname>
<given-names><![CDATA[JO]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Acute effects of the sigma-2 receptor agonist siramesine on lysosomal and extra-lysosomal proteolytic systems in lens epithelial cells]]></article-title>
<source><![CDATA[Mol Vis]]></source>
<year>2010</year>
<volume>16</volume>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tanaka]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sumioka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Fujita]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Kitano]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Okada]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Yamanaka]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Suppression of injury-induced epithelial-mesenchymal transition in a mouse lens epithelium lacking tenascin-C]]></article-title>
<source><![CDATA[Molecular Vision]]></source>
<year>2010</year>
<volume>16</volume>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weidmann]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kwittner]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Beck]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Teller]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Jonas]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Nebe]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevention of Lens Epithelial Cell Growth In Vitro Using Mibefradil-Containing PLGA Micro Particles]]></article-title>
<source><![CDATA[Open Ophthalmol J]]></source>
<year>2008</year>
<volume>2</volume>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Awasthi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Wang-Su]]></surname>
<given-names><![CDATA[ST]]></given-names>
</name>
<name>
<surname><![CDATA[Wagner]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Downregulation of MMP-2 and -9 by Proteasome Inhibition: A Possible Mechanism to Decrease LEC Migration and Prevent Posterior Capsular Opacification]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2008</year>
<month> M</month>
<day>ay</day>
<volume>49</volume>
<numero>5</numero>
<issue>5</issue>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Portes]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
<name>
<surname><![CDATA[Almeida]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Allodi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Monteiro]]></surname>
<given-names><![CDATA[ML]]></given-names>
</name>
<name>
<surname><![CDATA[Miguel]]></surname>
<given-names><![CDATA[NC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Trypan blue staining for capsulorhexis: Ultrastructural effect on lens epithelial cells and capsules]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2010</year>
<volume>36</volume>
<numero>4</numero>
<issue>4</issue>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Leysen]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Coeckelbergh]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Gobin]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Smet]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Daniel]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[De Groot]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cumulative neodimiun Yag laser rates after bag-in-the-lens and lens-in-the-bag intraocular lens implantation: comparative study]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>12</numero>
<issue>12</issue>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sacu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Menapace]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Wirtitsch]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Rainer]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of anterior capsule polishing on fibrotic capsule opacification: Three-year results]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2004</year>
<volume>30</volume>
<numero>11</numero>
<issue>11</issue>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sacu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Menapace]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Georgopoulos]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Kriechbaum]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Influence of optic edge design and anterior capsule polishing on posterior capsule fibrosis]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2004</year>
<volume>30</volume>
<numero>3</numero>
<issue>3</issue>
</nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bolz]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Menapace]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Sacu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Wirtitsch]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of anterior capsule polishing on the posterior capsule opacification-inhibiting properties of a sharp-edged, 3-piece, silicone intraocular lens: Three- and 5-year results of a randomized trial]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>http://www.ncbi.nlm.nih.gov/pubmed/16931265</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Menapace]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Wirtitsch]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Kriechbaum]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Sacu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effect of anterior capsule polishing on posterior capsule opacification and neodimium:YAG capsulotomy rates: Three-year randomized trial]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2005</year>
<volume>31</volume>
<numero>11</numero>
<issue>11</issue>
</nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zurresh]]></surname>
<given-names><![CDATA[KP]]></given-names>
</name>
<name>
<surname><![CDATA[Apple]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[McAvoy]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Maloof]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Milverton]]></surname>
<given-names><![CDATA[EJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Posterior capsule opacification (After cataract): Surgical and implant related factors for prevention]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Jitendar]]></surname>
<given-names><![CDATA[PV]]></given-names>
</name>
</person-group>
<source><![CDATA[Matering the Arts of Bimanual microincision Phaco (Phaconit/MICS)]]></source>
<year>2005</year>
<page-range>p. 396-420</page-range><publisher-loc><![CDATA[New Delhi ]]></publisher-loc>
<publisher-name><![CDATA[Jaypee Brothers]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tassignon]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Van Looveren]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bag-in-the-lens IOL implantation and pseudophakic retinal detachment]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Garg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Alió]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
</person-group>
<source><![CDATA[Mastering phaco chop techniques]]></source>
<year>2009</year>
<page-range>p. 213-5</page-range><publisher-loc><![CDATA[New Delhi ]]></publisher-loc>
<publisher-name><![CDATA[Jaypee Brothers]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[MS]]></given-names>
</name>
<name>
<surname><![CDATA[Ye]]></surname>
<given-names><![CDATA[YJ]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Luo]]></surname>
<given-names><![CDATA[WX]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Posterior continuous curvilinear capsulorhexis and optic capture of the posterior chamber intraocular lens in pediatric cataract surgery]]></article-title>
<source><![CDATA[Zhonghua Yan Ke Za Zhi]]></source>
<year>2006</year>
<month> M</month>
<day>ay</day>
<volume>42</volume>
<numero>5</numero>
<issue>5</issue>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Menapace]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Erradication of after-cataract by posterior capsulorhexis and optic buttonholing combined with anterior capsule polishing: A report of 1000 cases]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Garg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fine]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Mastering the techniques of advanced phaco surgery]]></source>
<year>2008</year>
<page-range>p. 394-401</page-range><publisher-loc><![CDATA[New Delhi ]]></publisher-loc>
<publisher-name><![CDATA[Jaypee Brothers]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yuen]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Batterbury]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Grierson]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Modification of the surface properties of a lens material to influence posterior capsular opacification]]></article-title>
<source><![CDATA[Clinical and Experimental Ophthalmology]]></source>
<year>2006</year>
<volume>34</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>568-74</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wegner]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Biocompatibility of intraocular lens materials]]></article-title>
<source><![CDATA[Current opinion in Ophthalmology]]></source>
<year>2008</year>
<volume>19</volume>
</nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[&#381;emaitiene]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Ja&#353;inskas]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Barzd&#382;iukas]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Auffarth]]></surname>
<given-names><![CDATA[GU]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevention of posterior capsule opacification using different intraocular lenses (results of one-year clinical study)]]></article-title>
<source><![CDATA[Medicina (Kaunas)]]></source>
<year>2004</year>
<volume>40</volume>
<numero>8</numero>
<issue>8</issue>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Flores Gaitán]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Morales Gómez]]></surname>
<given-names><![CDATA[ME]]></given-names>
</name>
<name>
<surname><![CDATA[Matiz]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Garzón]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Opacidad de la cápsula posterior después de facoemulsificación: Evaluación de varios tipos de lentes intraoculares]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>Mayo</year>
<month>-J</month>
<day>un</day>
<volume>79</volume>
<numero>3</numero>
<issue>3</issue>
</nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Katayama]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Kobayakawa]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Yanagawa]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tochikubo]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The relationship between the adhesion characteristics of acrylic intraocular lens materials and posterior capsule opacification]]></article-title>
<source><![CDATA[Ophthalmic Res]]></source>
<year>2007</year>
<volume>39</volume>
<numero>5</numero>
<issue>5</issue>
</nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Advances in optic designs to reduce PCO]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Garg]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Fine]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Mastering the techniques of advance phaco surgery]]></source>
<year>2008</year>
<page-range>p. 408-13</page-range><publisher-loc><![CDATA[New Delhi ]]></publisher-loc>
<publisher-name><![CDATA[Jaypee Brothers]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nishi]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Nishi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Sakanishi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Inhibition of migrating lens epithelial cells at the capsular bend created by the rectangular optic edge of a posterior chamber intraocular lens]]></article-title>
<source><![CDATA[Ophthalmic Surg Lasers]]></source>
<year>1998</year>
<volume>29</volume>
<numero>7</numero>
<issue>7</issue>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Boyce]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Bhermi]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
<name>
<surname><![CDATA[Spalton]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[El-Osta]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mathematical modeling of the forces between an intraocular lens and the capsule]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2002</year>
<volume>28</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>http://www.jcrsjournal.org/article/S0886-3350%2802%2901490-6/abstract</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Menapace]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Georgopoulos]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rainer]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Siegl]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of 4 methods for quantifying posterior capsule opacification]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2003</year>
<month> J</month>
<day>an</day>
<volume>29</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bender]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Spalton]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Uyanonvara]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Boyce]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Heatley]]></surname>
<given-names><![CDATA[Jose R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[POCOman: New system for quantifying posterior capsule opacification]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2004</year>
<volume>30</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>http://www.ncbi.nlm.nih.gov/pubmed/15474814</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Siegl]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Pinz]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Removal of Reflections in the Photographic Assessmentof PCO by Fusion of Digital Retroillumination Images]]></article-title>
<source><![CDATA[IOVS]]></source>
<year>Jan </year>
<month>20</month>
<day>03</day>
<volume>44</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grewal]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Jain]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Brar]]></surname>
<given-names><![CDATA[GS]]></given-names>
</name>
<name>
<surname><![CDATA[Grewal]]></surname>
<given-names><![CDATA[SPS]]></given-names>
</name>
<name>
<surname><![CDATA[Singh]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pentacam tomograms: A Novel Method for Quantification of Posterior Capsule Opacification]]></article-title>
<source><![CDATA[IOVS]]></source>
<year>2008</year>
<volume>49</volume>
<numero>5</numero>
<issue>5</issue>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Findl]]></surname>
<given-names><![CDATA[Oliver]]></given-names>
</name>
<name>
<surname><![CDATA[Buehl]]></surname>
<given-names><![CDATA[Wolf]]></given-names>
</name>
<name>
<surname><![CDATA[Bauer]]></surname>
<given-names><![CDATA[Peter]]></given-names>
</name>
<name>
<surname><![CDATA[Sycha]]></surname>
<given-names><![CDATA[Thomas]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Intervenciones para la prevención de la opacificación de la cápsula posterior]]></article-title>
<source><![CDATA[Biblioteca Cochrane Plus 2010 Número 2]]></source>
<year>2010</year>
<publisher-loc><![CDATA[Chichester^eUK UK]]></publisher-loc>
<publisher-name><![CDATA[John Wiley & Sons, Ltd]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hayash]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Nakao]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vivo quantitative measurement of posterior capsule opacification after extracapsular cataract surgery]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>1998</year>
<volume>125</volume>
<numero>6</numero>
<issue>6</issue>
</nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Nakao]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Quantitative comparison of posterior capsule opacification after polymethylmethacrylate, silicone, and soft acrylic intraocular lens implantation]]></article-title>
<source><![CDATA[Arch Ophthalmol]]></source>
<year>1998</year>
<volume>116</volume>
<numero>12</numero>
<issue>12</issue>
</nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Nakao]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Hayashi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reproducibility of posterior capsule opacification measurement using Scheimpflug videophotography]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>1998</year>
<volume>24</volume>
<numero>12</numero>
<issue>12</issue>
</nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saika]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Miyamoto]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Ishida]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Tanaka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Okada]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Nagane]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of Scheimpflug images of posterior capsule opacification and histological findings in rabbits and humans]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2001</year>
<volume>27</volume>
<numero>7</numero>
<issue>7</issue>
</nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aslam]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
<name>
<surname><![CDATA[Patton]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Rose]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[OSCA: a comprehensive open-access system of analysis of posterior capsular opacification]]></article-title>
<source><![CDATA[BMC Ophthalmol]]></source>
<year>2006</year>
<volume>6</volume>
<numero>30</numero>
<issue>30</issue>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>