<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-2176</journal-id>
<journal-title><![CDATA[Revista Cubana de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Oftalmol]]></abbrev-journal-title>
<issn>0864-2176</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-21762012000300011</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Beneficios del sistema Scheimpflug en glaucoma]]></article-title>
<article-title xml:lang="en"><![CDATA[Benefits of Scheimpflug system for the treatment of glaucoma]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Domínguez Randulfe]]></surname>
<given-names><![CDATA[Marerneda]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fernández Argones]]></surname>
<given-names><![CDATA[Liamet]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Miqueli Rodríguez]]></surname>
<given-names><![CDATA[Maritza]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Piloto Díaz]]></surname>
<given-names><![CDATA[Ibraín]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fumero González]]></surname>
<given-names><![CDATA[Francisco Yunier]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ferrer Guerra]]></surname>
<given-names><![CDATA[María Teresa]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Cubano de Oftalmología Ramón Pando Ferrer  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>00</month>
<year>2012</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>00</month>
<year>2012</year>
</pub-date>
<volume>25</volume>
<fpage>449</fpage>
<lpage>457</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762012000300011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-21762012000300011&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-21762012000300011&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Entre los medios diagnósticos que más se han difundido en los últimos años se encuentran los basados en las imágenes de Scheimpflug, como el Pentacam de Oculus Wetzlar de Alemania. Entre sus modelos de evaluación contiene la realización de la paquimetría central y curvatura corneal, así como fórmulas de corrección de la presión intraocular. Permite la medición de la amplitud angular y de la profundidad y volumen de la cámara anterior. Las publicaciones validan la alta reproducibilidad de sus mensuraciones por lo que se ha hecho útil en la evaluación del glaucoma.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Scheimpflug´s images as is the case of Oculus Wetzlar´s Pentacam from Germany, are one of the most widely known diagnostic techniques for the evaluation of the anterior segment of the eye. Its evaluating models comprise the central pachymetry and the corneal curvature as well as the correction formulas for the intraocular pressure. It allows the anterior chamber amplitude, volume and depth measurements with high reproducibility, being useful in the evaluation of glaucoma.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[pentacam]]></kwd>
<kwd lng="es"><![CDATA[cámara Scheimpflug]]></kwd>
<kwd lng="en"><![CDATA[pentacam]]></kwd>
<kwd lng="en"><![CDATA[Scheimpflug´s camera]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>REVISIONES</B></font></p>    <p align="right">&nbsp;</p>    <p align="left"><font size="2"><b><font size="4" face="Verdana, Arial, Helvetica, sans-serif">Beneficios  del sistema Scheimpflug en glaucoma</font></b></font></p>    <p align="left">&nbsp;</p>    <p align="left"><strong><font size="3" face="Verdana, Arial, Helvetica, sans-serif">Benefits  of Scheimpflug system for the treatment of glaucoma</font> </strong></p>    <p align="left">&nbsp;</p>    <p align="left">&nbsp;</p>    <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Dra.  Marerneda Dom&iacute;nguez Randulfe, Dra. Liamet Fern&aacute;ndez Argones, Dra.  Maritza Miqueli Rodr&iacute;guez, Dr. Ibra&iacute;n Piloto D&iacute;az, Dr. Francisco  Yunier Fumero Gonz&aacute;lez, Dra. Mar&iacute;a Teresa Ferrer Guerra</strong></font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Instituto  Cubano de Oftalmolog&iacute;a &quot;Ram&oacute;n Pando Ferrer&quot;. La Habana,  Cuba. </font></p>    <p>&nbsp;</p>    ]]></body>
<body><![CDATA[<p>&nbsp;</p><hr>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>RESUMEN</B>  </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Entre  los medios diagn&oacute;sticos que m&aacute;s se han difundido en los &uacute;ltimos  a&ntilde;os se encuentran los basados en las im&aacute;genes de Scheimpflug, como  el Pentacam de Oculus Wetzlar de Alemania. Entre sus modelos de evaluaci&oacute;n  contiene la realizaci&oacute;n de la paquimetr&iacute;a central y curvatura corneal,  as&iacute; como f&oacute;rmulas de correcci&oacute;n de la presi&oacute;n intraocular.  Permite la medici&oacute;n de la amplitud angular y de la profundidad y volumen  de la c&aacute;mara anterior. Las publicaciones validan la alta reproducibilidad  de sus mensuraciones por lo que se ha hecho &uacute;til en la evaluaci&oacute;n  del glaucoma.</font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>Palabras  clave</B>: pentacam, c&aacute;mara Scheimpflug. </font> <hr>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>ABSTRACT  </B> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Scheimpflug&acute;s  images as is the case of Oculus Wetzlar&acute;s Pentacam from Germany, are one  of the most widely known diagnostic techniques for the evaluation of the anterior  segment of the eye. Its evaluating models comprise the central pachymetry and  the corneal curvature as well as the correction formulas for the intraocular pressure.  It allows the anterior chamber amplitude, volume and depth measurements with high  reproducibility, being useful in the evaluation of glaucoma. </font></p>    <p> <font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>Key  words</B>: pentacam, Scheimpflug&#180;s camera. </font></p><hr>     <p>&nbsp;</p>    <p>&nbsp;</p>    <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>INTRODUCCI&Oacute;N  </B> </font></p>    ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En  el glaucoma existe una necesidad creciente de b&uacute;squeda de informaci&oacute;n  tanto desde el punto de vista cl&iacute;nico, como de tratamiento quir&uacute;rgico  de la enfermedad. El estudio de las im&aacute;genes con los medios diagn&oacute;sticos  contin&uacute;a como centro de constante revisi&oacute;n y es una de las principales  fuentes de reportes de investigaci&oacute;n. </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La  utilizaci&oacute;n a trav&eacute;s de los a&ntilde;os de herramientas como la  biomicroscopia, paquimetr&iacute;a ultras&oacute;nica, queratometr&iacute;a, topograf&iacute;a  basada en los discos de Pl&aacute;cido, biomicroscopia ultras&oacute;nica, microscopio  confocal entre otros, ha servido para valorar y diagnosticar las estructuras del  segmento anterior. Pero sin &aacute;nimo de discriminar, puesto que a&uacute;n  son &uacute;tiles en el trabajo diario, a pesar de sus aportes han validado sus  limitaciones con el advenimiento de otras tecnolog&iacute;as como las basadas  en el principio de Scheimpflug. Actualmente se dispone del Pentacam de Oculus,  Wetzlar Alemania, que ha revolucionado el quehacer diario, sobre todo en lo relacionado  con la cirug&iacute;a. El objetivo fue de generalizar y confirmar su utilidad  en glaucoma, basado en lo obtenido de una exhaustiva revisi&oacute;n de la literatura  y la pr&aacute;ctica.<SUP>1</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los  primeros pasos para el surgimiento de esta tecnolog&iacute;a est&aacute;n dados  en las referencias de Jules Carpenter, a inicios del siglo pasado, quien fuera  creador de una c&aacute;mara de lente inclinado para aumentar la profundidad del  foco en la fotograf&iacute;a arquitect&oacute;nica. Jules planteaba que &quot;<em>...si  dos planos eran lo suficientemente prolongados, estos se deb&iacute;an interceptar  en un plano perpendicular a dicho eje pasando a trav&eacute;s del centro &oacute;ptico  de la lente...</em>&quot;. En 1904 en Viena, Theodor Scheimpflug, a quien debemos  el nombre de la tecnolog&iacute;a en la actualidad, mejora y patentiza este dise&ntilde;o,  pero solo fue aplicado con fines militares. D&eacute;cadas m&aacute;s tarde, un  grupo de investigadores dirigidos por el profesor alem&aacute;n Hockwin, asociado  a compa&ntilde;&iacute;as &oacute;pticas, desarrollan un dispositivo con esta  tecnolog&iacute;a incorporada que ha venido mejor&aacute;ndose hasta nuestros  d&iacute;as.<SUP>2</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El  principio de Scheimpflug establece que una c&aacute;mara de gran formato consigue  la m&aacute;xima profundidad de campo en el plano del motivo cuando las prolongaciones  imaginarias de &eacute;ste, el del objetivo y el de la imagen, coinciden en un  punto com&uacute;n. Se utiliza para determinar la posici&oacute;n de la c&aacute;mara  cuando el motivo ocupa un plano oblicuo a esta, y permite obtener la m&aacute;xima  nitidez.<SUP>2</SUP> </font></p>    <p>&nbsp;</p>    <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>DESARROLLO  </B></font></p>    <p><font size="2"><b><font face="Verdana, Arial, Helvetica, sans-serif">Pentacam</font></b></font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Este  consta de una c&aacute;mara tipo Scheimpflug rotacional, capaz de crear una panor&aacute;mica  en tiempo real del segmento anterior. Esta se extiende desde la superficie anterior  de la c&oacute;rnea (incluye su zona central), hasta la parte posterior del cristalino;  genera im&aacute;genes con elevada precisi&oacute;n y resoluci&oacute;n en un  tiempo extremadamente corto, tan solo 2 segundos. De forma no invasiva (no contacto),  captura unas 50 im&aacute;genes de hendidura individuales, al girar alrededor  del ojo de 0 a 180&#186;. Para cada imagen eval&uacute;a unos 500 puntos de medida,  los que sumar&iacute;an 25 000 puntos de elevaci&oacute;n que crean una imagen  bidimensional o tridimensional exacta del segmento anterior. Contiene adem&aacute;s  2 c&aacute;maras que constituyen un sistema de seguridad autom&aacute;tico, una  para controlar la fijaci&oacute;n, de disposici&oacute;n central que corrige cualquier  movimiento del ojo, y otra montada sobre una rueda que gira para capturar las  im&aacute;genes de hendidura, inclusive en tejido corneal patol&oacute;gico.<SUP>2,3</SUP>  </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Estas  im&aacute;genes se digitalizan y transfieren a la computadora, donde se calcula  un modelo virtual tridimensional del segmento anterior. A partir de este se genera  informaci&oacute;n adicional, permite magnificar las im&aacute;genes, hacer comparaciones  o mediciones, ajustes en el contraste o animarlas. Adem&aacute;s realiza el an&aacute;lisis  de Zernicke para la superficie anterior y posterior y se basa en las mediciones  de elevaci&oacute;n del cristalino.<SUP>1,4</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Este  equipo ofrece determinados modelos de evaluaci&oacute;n entre los que la tomograf&iacute;a  tipo Scheimpflug es uno de los m&aacute;s novedosos (<a href="#f0111312">Fig.  1</a>). Permite una reconstrucci&oacute;n tridimensional corneal, al evaluar sus  curvaturas anterior y posterior adem&aacute;s de crear un mapa paquim&eacute;trico.  </font></p>    ]]></body>
<body><![CDATA[<p align="center"><a name="f0111312"></a><img src="/img/revistas/oft/v25s3/f0111312.jpg" alt="f0111312" width="420" height="353"></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La  topograf&iacute;a de la c&oacute;rnea anterior y posterior, y los mapas de elevaci&oacute;n  se realizan mediante un estudio del espesor corneal con luz de hendidura. Esto  permite analizar la cara anterior, posterior y la zona central. A partir de los  datos adquiridos mediante las im&aacute;genes de hendidura se construyen los mapas  de elevaci&oacute;n de ambas caras. Utiliza esferas de referencias, o mejor de  ajuste, para medir las distancias en micras del perfil corneal real con respecto  a esta referencia.<SUP>5 </SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Resulta  muy &uacute;til en la pesquisa y seguimiento de pacientes con ectasias (queratocono),  identificaciones de opacidades sutiles de la c&oacute;rnea, evaluaci&oacute;n  de cambios en pacientes bajo tratamiento por diversos des&oacute;rdenes corneales;  as&iacute; como para la decisi&oacute;n de remoci&oacute;n de suturas en ojos  sometidos a queratoplastia penetrante. Constituye un instrumento de valor incalculable  para la cirug&iacute;a refractiva, porque aporta las medidas precisas del centro  de la c&oacute;rnea, aunque sigue limitado en el estudio de la pel&iacute;cula  lagrimal.<SUP>6-8</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La  queratometr&iacute;a y paquimetr&iacute;a se efect&uacute;an para calcular el  espesor corneal en el centro de la pupila y apical. La c&aacute;mara mide desde  la cima del epitelio hasta la superficie anterior del endotelio. El espesor de  la c&oacute;rnea se proyecta de limbo a limbo, como una imagen a color sobre su  &aacute;rea, y puede ser evaluado el espesor real corneal mediante la funci&oacute;n  num&eacute;rica en cualquier localizaci&oacute;n o elegir determinada &aacute;rea.  Este modelo incluye el ajuste de la presi&oacute;n intraocular (PIO) en relaci&oacute;n  al valor del espesor corneal.<SUP>9,10</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><I>Alezzandrini</I>  y otros realizaron un estudio para comparar la medici&oacute;n del valor real  del espesor corneal central mediante paquimetr&iacute;a ultras&oacute;nica y el  Pentacam. No se obtuvo resultados estad&iacute;sticamente significativos que propongan  la superioridad del Pentacam en este sentido.<SUP>11</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La  densitometr&iacute;a de la c&oacute;rnea y del cristalino ha servido para evidenciar  la progresi&oacute;n de la esclerosis lenticular. Tambi&eacute;n permite diagnosticar  y documentar la opacificaci&oacute;n de la c&aacute;psula posterior, en especial  las perlas de Elsching; as&iacute; como el s&iacute;ndrome de distensi&oacute;n  del saco capsular.<SUP>12</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El  m&oacute;dulo del c&aacute;lculo de la lente intraocular, mejorado para pacientes  despu&eacute;s de cirug&iacute;a refractiva, incorpora el <I>Holladay Report</I>.  Se calcula el radio entre los poderes posterior y frontal de la c&oacute;rnea;  as&iacute; como las <I>Equivalent K-Readings</I>, que pueden ser implantadas hacia  las f&oacute;rmulas de c&aacute;lculo de la lente intraocular para obtener un  poder m&aacute;s preciso, a&uacute;n en pacientes con c&oacute;rneas patol&oacute;gicas.  As&iacute; mismo ofrece una biometr&iacute;a exacta que ser&iacute;a de gran utilidad  en pacientes operados con LASIK para prevenir sorpresas refractivas. En un futuro,  este an&aacute;lisis cobrar&aacute; mayor jerarqu&iacute;a al incrementarse el  n&uacute;mero de casos que requieran de la cirug&iacute;a de catarata.<SUP>13-15</SUP>  </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El an&aacute;lisis  de la c&aacute;mara anterior (CA) tridimensional (profundidad y volumen de CA,  amplitud angular) adquiere vital importancia en candidatos de lentes f&aacute;quicos  &oacute; t&oacute;ricos. Esto posibilita que se evite inducir un mayor astigmatismo  al ser desplazado de su eje y su seguimiento reduce el riesgo de complicaciones  futuras, como el desarrollo de cataratas o la opacificaci&oacute;n de la c&aacute;psula.<SUP>16</SUP>  </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se sugiere  desde hace varios a&ntilde;os, la necesidad de una identificaci&oacute;n precoz  de los cambios en la curvatura posterior de la c&oacute;rnea. <I>Belin</I>, ha  sido uno de los investigadores que m&aacute;s ha resaltado la importancia de contar  con un m&eacute;todo preciso para estudiar la elevaci&oacute;n posterior de la  c&oacute;rnea en ojos operados por LASIK.<SUP>17</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Espec&iacute;ficamente  para el paciente glaucomatoso, que requiere de un estudio tomogr&aacute;fico estructural  de la parte anterior del ojo, donde se determina grado de apertura angular de  forma objetiva y la influencia del espesor c&oacute;rneal en las cifras de PIO,  resulta fundamental este equipo. El Pentacam permite, mediante sus programas,  corregir la PIO, medir la amplitud angular, y la profundidad (PCA) y volumen (VCA)  de la c&aacute;mara anterior. </font></p>    ]]></body>
<body><![CDATA[<p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Para  la correcci&oacute;n de la PIO, que puede ser realizada a trav&eacute;s de un  ajuste acorde al resultado de la paquimetr&iacute;a del sistema, es necesaria  la introducci&oacute;n del dato de la tonometr&iacute;a mediante un usuario (<a href="#f0211312">Fig.  2</a>). Para este resultado se debe optar por alguna de las f&oacute;rmulas incluidas,  se prefiere la f&oacute;rmula de Orssengo que difiere del resto al contener en  su c&aacute;lculo, el espesor y la curvatura corneal.<SUP>1,18</SUP> </font></p>    <p align="center"><a name="f0211312"></a><img src="/img/revistas/oft/v25s3/f0211312.jpg" alt="f0211312" width="420" height="349"></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La  medici&oacute;n de la amplitud angular, al ser un m&eacute;todo de no contacto,  es &uacute;til en pacientes no colaboradores a la t&eacute;cnica de gonioscopia  tradicional o con opacidades corneales. Aunque puede ser efectuada con cierta  limitaci&oacute;n, por la interferencia del p&aacute;rpado en el sector superior  que no permite que se ejecute simult&aacute;neamente en los 360&#186;. Se debe  seleccionar el segmento a estudiar y de esta forma se obtendr&aacute;n los valores  automatizados, pueden hacerse correcciones manuales. Es necesario conocer las  limitaciones del equipo para identificar el espol&oacute;n escleral, esto hace  imprecisa la medici&oacute;n del &aacute;ngulo camerular. Para visualizar de forma  directa estructuras angulares y relacionadas (cuerpo ciliar, espol&oacute;n escleral  y sulcus), se debe recurrir a tecnolog&iacute;as que empleen l&aacute;ser &oacute;  ultrasonidos de alta frecuencia y mayor &aacute;rea de barrido, y constituyen  mejores alternativas la tomograf&iacute;a de coherencia &oacute;ptica del segmento  anterior o la biomicroscopia ultras&oacute;nica. Desafortunadamente esta generaci&oacute;n  del equipo no lo permite debido a la reflectividad de la superficie escleral (<a href="#f0311312">Fig.  3</a>).<SUP>1,19,20 </SUP> </font></p>    <p align="center"><a name="f0311312"></a><IMG SRC="/img/revistas/oft/v25s3/f0311312.jpg" ALT="f0311312" WIDTH="420" HEIGHT="363"></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La  medici&oacute;n del la profundidad y volumen de la c&aacute;mara anterior (<a href="#f0411312">Fig.  4</a>) se facilita de modo autom&aacute;tico en un mapa a color. La profundidad  se puede tomar en su &aacute;rea central y en los cuatro puntos cardinales de  la media periferia, adem&aacute;s tiene incorporada la posibilidad de medir cualquier  punto de forma manual, y se obtienen resultados de alta precisi&oacute;n tras  procedimientos de iridotom&iacute;a perif&eacute;rica l&aacute;ser en pacientes  con &aacute;ngulos estrechos. <I>Grewall</I> y otros<SUP>21</SUP> han aceptado  los cambios que se producen en el volumen y profundidad de la c&aacute;mara anterior  mediante el escaneo autom&aacute;tico de im&aacute;genes desde el eje &oacute;ptico  hasta el limbo, en las horas 3, 9, 12 y 6. Los valores utilizados para la profundidad  a 4 y 8 mm, demostraron que la iridotom&iacute;a perif&eacute;rica l&aacute;ser  aumenta significativamente el volumen y la profundidad, especialmente a 8 mm en  todos los horarios, al aumentar la distancia del eje &oacute;ptico. Sin embargo,  no demostr&oacute; resultados estad&iacute;sticamente significativos de estos  estudios a 4 mm. </font></p>    <p align="center"><a name="f0411312"></a><img src="/img/revistas/oft/v25s3/f0411312.jpg" alt="f0411312" width="420" height="379"></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Al  proporcionar una estimaci&oacute;n cuantitativa del volumen de la c&aacute;mara  anterior, esta medici&oacute;n puede ser considerada para la pesquisa, durante  los ex&aacute;menes oftalmol&oacute;gicos de rutina, de ojos con &aacute;ngulos  estrechos y en riesgo de desarrollar ataques agudos. As&iacute; mismo, se puede  evaluar las respuestas una vez que sean sometidos a tratamientos de iridotom&iacute;a  o iridoplastia.<SUP>22</SUP> Tambi&eacute;n se ha propuesto su aplicaci&oacute;n  en el estudio de la profundidad de la ampolla de filtraci&oacute;n mediante medici&oacute;n  manual o para visualizar en c&aacute;mara anterior implantes de drenaje.<SUP>1,23,24</SUP>  </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Al estar  basado en la ley de Scheimpflug, este equipo tiene limitaciones al no poder medir  nada que no sea &oacute;pticamente visible, no proporciona una medida sulcus a  sulcus v&aacute;lida, solo medidas blanco a blanco y &aacute;ngulo a &aacute;ngulo.  Si existe cierre angular, identifica de forma equ&iacute;voca como &aacute;ngulo,  la zona de aposici&oacute;n iridocorneal, por la reflectividad de la luz intensa  sobre &eacute;sta. Adem&aacute;s no incorpora la posibilidad del estudio de la  pel&iacute;cula lagrimal. <SUP>24</SUP> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>Avances  del sistema</B> </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La  nueva generaci&oacute;n de estas c&aacute;maras cuenta con el <I>High Resolution  Pentacam</I>, que facilita la obtenci&oacute;n de mejores fotos Scheimpflug y  la proyecci&oacute;n de im&aacute;genes m&aacute;s especificas de implante de  la lente intraocular y de las capas de la c&oacute;rnea, equivalentes a las obtenidas  con tom&oacute;grafos del segmento anterior. Al tener incorporada una c&aacute;mara  de mayor resoluci&oacute;n (1,45 Mg pixel), permite la captura de al menos 100  im&aacute;genes en menos de 2 segundos.<SUP>25</SUP> </font></p>    ]]></body>
<body><![CDATA[<p>&nbsp;</p>    <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>CONCLUSIONES</B>  </font></p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El Pentacam  es una herramienta vers&aacute;til y de gran trascendencia para el campo de las  investigaciones. El sistema de Scheimpflug, incorporado en su dise&ntilde;o tecnol&oacute;gico,  lo ha convertido en un instrumento para el estudio del segmento anterior. De gran  utilidad en candidatos a cirug&iacute;a refractiva corneal e implantaci&oacute;n  de lentes f&aacute;quicas, por su alta reproducibilidad y habilidad de escaneo  de forma f&aacute;cil, r&aacute;pida y sin sesgo por parte del operador. Para  el glaucoma tambi&eacute;n ha demostrado sus beneficios en el estudio de pacientes  afectos de esta temible enfermedad, sobre todo en aquellos con &aacute;ngulo estrecho.  Quiz&aacute;s en un futuro no muy lejano, con una mejor&iacute;a de su tecnolog&iacute;a  para superar las limitaciones que presenta, se pueda dar respuestas a interrogantes  actuales. </font></p>    <p>&nbsp;</p>    <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>REFERENCIAS  BIBLIOGR&Aacute;FICAS</B> </font></p>    <p> </p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">1.  Morcillo R, Mu&ntilde;oz F, Dur&aacute;n S<SUP>. </SUP>La c&aacute;mara Scheimpflug  rotacional Pentacam. Studium. 2006 [citado 2012 septiembre 4];XXIV(4). Disponible  en: <a href="http://www.oftalmo.com/studium/studium2006/stud06-4/06d-04.htm" target="_blank">http://www.oftalmo.com/studium/studium2006/stud06-4/06d-04.htm</a>  </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">2. Verges  C, Cazal J. Aplicaciones del Pentacam en el an&aacute;lisis del segmento anterior.  Highlights of Ophthalmology. 2007;35(3):12-6.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">3.  Capote A, Jare&ntilde;o M, G&oacute;mez Z, Fern&aacute;ndez K. Queratocono y otras  ectasias corneales. En: R&iacute;o Torres M, Capote Cabrera A, Hern&aacute;ndez  Silva JR, Egu&iacute;as Mart&iacute;nez F, Padilla Gonz&aacute;lez CM. Oftalmolog&iacute;a  criterios y tendencias actuales. La Habana: Editorial Ciencias M&eacute;dicas;  2009. p. 59-77.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">4.  Oculus [Internet]. Pentacam de oculus [actualizado 2009; citado 3 enero de 2012].  Disponible en: <a href="http://www.oculus.de/es/sites/detail_ger.php?page=322" target="_blank">http://www.oculus.de/es/sites/detail_ger.php?page=322</a></font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">5.  Neuhan H T. Perspectiva del sistema Pentacam entendiendo sus beneficios. Highlights  of </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Ophthalmology.  2007;35(3):13.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">6.  Vega B, Cuevas J, Hern&aacute;ndez S. Fundamentos de la topograf&iacute;a corneal.  En: R&iacute;o Torres M, Capote Cabrera A, Hern&aacute;ndez Silva JR, Egu&iacute;as  Mart&iacute;nez F, Padilla Gonz&aacute;lez CM. Oftalmolog&iacute;a criterios y  tendencias actuales. La Habana: Editorial Ciencias M&eacute;dicas; 2009. p. 111-20.      </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">7. Sim&oacute;ny  C. Fundamentos de topograf&iacute;a corneal. En: Atlas de cirug&iacute;a refractiva.  Bogot&aacute;, Colombia: D'vinni Editorial; 2000. p. 9-59.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">8.  Quisling S, Sjoberg S, Zimmerman B, Goins K, Sutphin J. Comparison of Pentacam  and Orbscan IIz on Posterior curvature topography measurements in keratoconus  eyes. Ophthalmology. 2006;113(9):1629-32.     </font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">9.  Machado E. Aberrometria. En: R&iacute;o Torres M, Capote Cabrera A, Hern&aacute;ndez  Silva JR, Egu&iacute;as Mart&iacute;nez F, Padilla Gonz&aacute;lez CM. Oftalmolog&iacute;a  criterios y tendencias actuales. La Habana: Editorial Ciencias M&eacute;dicas;  2009. p. 173-81.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">10.  Lackner B, Schmidinger G, Pieh S, Funovics M, Skorpik C. Repeatibility and reproductibility  of central corneal thickness measurement with Pentacam, Orbscan and Ultrasound.  Optometry and Vision Science. 2005;82(10):892-9.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">11.  Alezzandrini H. Estudio comparativo de medici&oacute;n del espesor corneal central  utilizando Paquimetr&iacute;a Ultras&oacute;nica y Pentacam. Arch Oftal B Aires.  2009;80(2):71-3.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">12.  Satinder G. Evaluaci&oacute;n de patolog&iacute;as del segmento anterior usando  Pentacam. Highligts of Oftalmology. 2007;36(4):17-20.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">13.  P&eacute;rez E. C&aacute;lculo de la lente intraocular en la cirug&iacute;a de  catarata. En: R&iacute;o Torres M, Capote Cabrera A, Hern&aacute;ndez Silva JR,  Egu&iacute;as Mart&iacute;nez F, Padilla Gonz&aacute;lez CM. Oftalmolog&iacute;a  criterios y tendencias actuales. La Habana: Editorial Ciencias M&eacute;dicas;  2009. p. 223-43.     </font></p>    ]]></body>
<body><![CDATA[<!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">14.  Kent C. Calculando la potencia Post-Lasik de las lentes intraoculares. Review  of Ophthalmology. 2008;8(2):16-24.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">15.  Onnis R. Facoemulsificacion poscirug&iacute;a refractiva corneal. En: Centurion  V, Nicoli C, Villar Kuri J (editores). El libro del cristalino de las Am&eacute;ricas.  Brasil: Livraria Santos; 2007. p. 777-82.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">16.  Lackner B, Schmidinger G, Skorpik Ch. Validity and repeatability of anterior chamber  depth measurements with Pentacam and Orbscan. Optom Vis Sci. 2005;82(9):858-61.      </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">17.  Belin MW. Keratoconus ectasia detection with the Oculus Pentacam. Highlights of  Ophthalmology. 2007;35(6):5-12.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">18.  Ramos JF, G&aacute;lvez J, Mej&iacute;as MI. Comparaci&oacute;n antes y despu&eacute;s  de la cirug&iacute;a de cataratas de la PIO, profundidad CA y angulaci&oacute;n  camerular medida con Pentacam. 22 Congreso SECOIR; 9-12 mayo 2007; Benidorm. Disponible  en: <a href="http://www.oftalmo.com/secoir/congreso2007/programa10.htm" target="_blank">http://www.oftalmo.com/secoir/congreso2007/programa10.htm</a>  </font><!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">19.  Flores I. Gilbert M E, Ruiz N. Cambios del segmento anterior medidos con Pentacam  despu&eacute;s de iridotomia con Yag en pacientes con &aacute;ngulos estrechos.  Rev Mex Oftalmol. 2007;81(5):246-9.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">20.  Sharan S, Grigg JR, Higgins RA. Nanoftalmos: Ultrasound biomicroscopy and Pentacam  assessment of angle structures before and after cataract surgery. J Cataract Refract  Surg. 2006;32(6):1052-5.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">21.  Satinder G. Evaluaci&oacute;n del segmento anterior despu&eacute;s de iridotom&iacute;a  perif&eacute;rica l&aacute;ser usando el sistema Pentacam en ojos con cierre primario  del &aacute;ngulo (CPA). Highligts of Ophthalmology. 2007;36(4):13-4.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">22.  Arredondo S, Castellanos MA, Ruiz N, Naranjo R. Reproducibilidad de la medida  del &aacute;ngulo iridocorneal con el uso de Pentacam, c&aacute;mara rotatoria  tipo Scheimpflug. Rev Mex Oftalmol. 2009;83(2):106-9.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">23.  Rabsilber TM, Khoramnia R, Auffart GU. Anterior chamber measurements using Pentacam  rotating Scheimpflug camera. J Cataract Refract Surg. 2006;32(3):456-9.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">24.  Hashemi H, Mehravaran S. Central corneal thickness measurement with Pentacam,  Orbscan II, and ultrasound devices before and after refractive surgery for myopia.  J Cataract Refract Surg. 2007;33(10):1701-7.     </font></p>    <!-- ref --><p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">25.  Crisanti D, Rafael Q, Naranjo R, Ozorno Jorge, Gil F. Inducci&oacute;n de cambio  en el patr&oacute;n topogr&aacute;fico en la cirug&iacute;a filtrante de glaucoma.  Rev Oftalmol Venez. 2005;61(3):142-6.    </font></p>    <p>&nbsp;</p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Recibido:  8 de marzo de 2012. </font>     <br> <font size="2" face="Verdana, Arial, Helvetica, sans-serif">Aprobado:  8 de abril de 2012. </font></p>    <p>&nbsp;</p>    <p>&nbsp;</p>    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Dra.  <I>Marerneda Dom&iacute;nguez Randulfe</I>. Instituto Cubano de Oftalmolog&iacute;a  &quot;Ram&oacute;n Pando Ferrer&quot;. Ave. 76 No. 3104 entre 31 y 41 Marianao,  La Habana, Cuba. Correo electr&oacute;nico: <a href="mailto:marernedadguez@infomed.sld.cu">marernedadguez@infomed.sld.cu</a></font></p>     ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morcillo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Durán]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La cámara Scheimpflug rotacional Pentacam]]></article-title>
<source><![CDATA[Studium]]></source>
<year>2006</year>
<volume>XXIV</volume>
<numero>4</numero>
<issue>4</issue>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Verges]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Cazal]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Aplicaciones del Pentacam en el análisis del segmento anterior]]></article-title>
<source><![CDATA[Highlights of Ophthalmology.]]></source>
<year>2007</year>
<volume>35</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>12-6</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Capote]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Jareño]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gómez]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Fernández]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Queratocono y otras ectasias corneales]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Río Torres]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Capote Cabrera]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández Silva]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Eguías Martínez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Padilla González]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
</person-group>
<source><![CDATA[Oftalmología criterios y tendencias actuales]]></source>
<year>2009</year>
<page-range>p. 59-77</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="">
<source><![CDATA[Oculus: Pentacam de oculus]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Neuhan H]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Perspectiva del sistema Pentacam entendiendo sus beneficios]]></article-title>
<source><![CDATA[Highlights of Ophthalmology.]]></source>
<year>2007</year>
<volume>35</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>13</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Vega]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Cuevas]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Fundamentos de la topografía corneal]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Río Torres]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Capote Cabrera]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández Silva]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Eguías Martínez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Padilla González]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
</person-group>
<source><![CDATA[Oftalmología criterios y tendencias actuales]]></source>
<year>2009</year>
<page-range>p. 111-20</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Simóny]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Fundamentos de topografía corneal]]></article-title>
<source><![CDATA[Atlas de cirugía refractiva]]></source>
<year>2000</year>
<page-range>p. 9-59</page-range><publisher-loc><![CDATA[Bogotá ]]></publisher-loc>
<publisher-name><![CDATA[D'vinni Editorial]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Quisling]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sjoberg]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Zimmerman]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Goins]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Sutphin]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of Pentacam and Orbscan IIz on Posterior curvature topography measurements in keratoconus eyes]]></article-title>
<source><![CDATA[Ophthalmology.]]></source>
<year>2006</year>
<volume>113</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1629-32</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Machado]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Aberrometria]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Río Torres]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Capote Cabrera]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández Silva]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Eguías Martínez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Padilla González]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
</person-group>
<source><![CDATA[Oftalmología criterios y tendencias actuales]]></source>
<year>2009</year>
<page-range>p. 173-81</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lackner]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Schmidinger]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Pieh]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Funovics]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Skorpik]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Repeatibility and reproductibility of central corneal thickness measurement with Pentacam, Orbscan and Ultrasound]]></article-title>
<source><![CDATA[Optometry and Vision Science.]]></source>
<year>2005</year>
<volume>82</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>892-9</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alezzandrini]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estudio comparativo de medición del espesor corneal central utilizando Paquimetría Ultrasónica y Pentacam]]></article-title>
<source><![CDATA[Arch Oftal B Aires.]]></source>
<year>2009</year>
<volume>80</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>71-3</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Satinder]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Evaluación de patologías del segmento anterior usando Pentacam]]></article-title>
<source><![CDATA[Highligts of Oftalmology.]]></source>
<year>2007</year>
<volume>36</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>17-20</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de la lente intraocular en la cirugía de catarata]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Río Torres]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Capote Cabrera]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández Silva]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Eguías Martínez]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Padilla González]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
</person-group>
<source><![CDATA[Oftalmología criterios y tendencias actuales]]></source>
<year>2009</year>
<page-range>p. 223-43</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kent]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Calculando la potencia Post-Lasik de las lentes intraoculares]]></article-title>
<source><![CDATA[Review of Ophthalmology.]]></source>
<year>2008</year>
<volume>8</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>16-24</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Onnis]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Facoemulsificacion poscirugía refractiva corneal]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Centurion]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Nicoli]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Villar Kuri]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[El libro del cristalino de las Américas]]></source>
<year>2007</year>
<page-range>p. 777-82</page-range><publisher-loc><![CDATA[^eBrasil Brasil]]></publisher-loc>
<publisher-name><![CDATA[Livraria Santos]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lackner]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Schmidinger]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Skorpik]]></surname>
<given-names><![CDATA[Ch]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan]]></article-title>
<source><![CDATA[Optom Vis Sci.]]></source>
<year>2005</year>
<volume>82</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>858-61</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Belin]]></surname>
<given-names><![CDATA[MW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Keratoconus ectasia detection with the Oculus Pentacam]]></article-title>
<source><![CDATA[Highlights of Ophthalmology.]]></source>
<year>2007</year>
<volume>35</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>5-12</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramos]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Gálvez]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Mejías]]></surname>
<given-names><![CDATA[MI]]></given-names>
</name>
</person-group>
<source><![CDATA[Comparación antes y después de la cirugía de cataratas de la PIO, profundidad CA y angulación camerular medida con Pentacam]]></source>
<year></year>
<conf-name><![CDATA[22 Congreso SECOIR]]></conf-name>
<conf-date>9-12 mayo 2007</conf-date>
<conf-loc>Benidorm </conf-loc>
</nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Flores]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Gilbert]]></surname>
<given-names><![CDATA[M E]]></given-names>
</name>
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cambios del segmento anterior medidos con Pentacam después de iridotomia con Yag en pacientes con ángulos estrechos]]></article-title>
<source><![CDATA[Rev Mex Oftalmol.]]></source>
<year>2007</year>
<volume>81</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>246-9</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sharan]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Grigg]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Higgins]]></surname>
<given-names><![CDATA[RA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nanoftalmos: Ultrasound biomicroscopy and Pentacam assessment of angle structures before and after cataract surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2006</year>
<volume>32</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1052-5</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Satinder]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Evaluación del segmento anterior después de iridotomía periférica láser usando el sistema Pentacam en ojos con cierre primario del ángulo (CPA)]]></article-title>
<source><![CDATA[Highligts of Ophthalmology.]]></source>
<year>2007</year>
<volume>36</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>13-4</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Arredondo]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Castellanos]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Naranjo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Reproducibilidad de la medida del ángulo iridocorneal con el uso de Pentacam, cámara rotatoria tipo Scheimpflug]]></article-title>
<source><![CDATA[Rev Mex Oftalmol.]]></source>
<year>2009</year>
<volume>83</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>106-9</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rabsilber]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
<name>
<surname><![CDATA[Khoramnia]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Auffart]]></surname>
<given-names><![CDATA[GU]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Anterior chamber measurements using Pentacam rotating Scheimpflug camera]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2006</year>
<volume>32</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>456-9</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hashemi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Mehravaran]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after refractive surgery for myopia]]></article-title>
<source><![CDATA[J Cataract Refract Surg.]]></source>
<year>2007</year>
<volume>33</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1701-7</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Crisanti]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Rafael]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
<name>
<surname><![CDATA[Naranjo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Ozorno]]></surname>
<given-names><![CDATA[Jorge]]></given-names>
</name>
<name>
<surname><![CDATA[Gil]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Inducción de cambio en el patrón topográfico en la cirugía filtrante de glaucoma]]></article-title>
<source><![CDATA[Rev Oftalmol Venez.]]></source>
<year>2005</year>
<volume>61</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>142-6</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
