<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-2176</journal-id>
<journal-title><![CDATA[Revista Cubana de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Oftalmol]]></abbrev-journal-title>
<issn>0864-2176</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-21762016000100010</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Principios para el cálculo de la lente intraocular tras cirugía refractiva corneal]]></article-title>
<article-title xml:lang="en"><![CDATA[Principles for the intraocular lens power calculation after corneal refractive surgery]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cárdenas Díaz]]></surname>
<given-names><![CDATA[Taimí]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Guerra Almaguer]]></surname>
<given-names><![CDATA[Michel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández López]]></surname>
<given-names><![CDATA[Iván]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cruz Izquierdo]]></surname>
<given-names><![CDATA[Dunia]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Montero Díaz]]></surname>
<given-names><![CDATA[Eric]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández Silva]]></surname>
<given-names><![CDATA[Raúl]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Cubano de Oftalmología Ramón Pando Ferrer  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>03</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>03</month>
<year>2016</year>
</pub-date>
<volume>29</volume>
<numero>1</numero>
<fpage>0</fpage>
<lpage>0</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762016000100010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-21762016000100010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-21762016000100010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se estima que aproximadamente un millón o más de pacientes se realizan cirugía refractiva al año. Es por eso que con el envejecimiento son cada día más frecuentes los pacientes con catarata, a quienes previamente se les ha efectuado cirugía refractiva. El cálculo inexacto de la potencia dióptrica de la lente a implantar en la intervención de estos es también un problema de importancia creciente y con él la sorpresa refractiva. Este es mucho más complejo de lo normal, ya que existen dos fuentes de error: la incorrecta predicción de la posición efectiva de la lente por parte de la fórmula y la determinación errónea de la potencia de la córnea por parte de la queratometría. La corrección de estos dos factores permitirá realizar un cálculo correcto en estos ojos. De ahí la motivación para realizar una búsqueda actualizadas de los últimos diez años de diversos artículos publicados, con el objetivo de describir los principios para el cálculo de la lente intraocular tras cirugía refractiva corneal. Se utilizó la plataforma Infomed, específicamente la Biblioteca Virtual de Salud, con todos sus buscadores.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[It is considered that approximately one million or more patients undergo refractive surgery every year. Due to aging, the number of patients with cataract, who had previously undergone refractive surgery, is increasingly higher. The inaccurate calculation of the dioptric power of the lens to be implanted is also a growing significant problem and thus the refractive surprise. This is a much more complex situation since two error sources exist: the incorrect prediction of the effective position of the lens based on the formula and the wrong determination of the corneal power through keratometry. The correction of these two factors will allow making a suitable power calculation. Hence the motivation for updated search of several articles published in the last ten years, with the objective of describing the principles for intraocular lens power calculation after corneal refractive surgery. The Infomed platform, mainly the Virtual Library of Health, was fully used.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[cirugía refractiva corneal]]></kwd>
<kwd lng="es"><![CDATA[poder corneal]]></kwd>
<kwd lng="es"><![CDATA[cálculo de lente intraocular]]></kwd>
<kwd lng="en"><![CDATA[corneal refractive surgery]]></kwd>
<kwd lng="en"><![CDATA[corneal power]]></kwd>
<kwd lng="en"><![CDATA[intraocular lens power calculation]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[  	    <p align="right" style='text&#45;align:right'><font face="verdana" size="2"><b>REVISI&Oacute;N</b></font></p>  	    <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:200%;text&#45;autospace:none'><font face="verdana" size="2"><b>&nbsp;</b></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2"><b><font size="4">Principios    para el c&aacute;lculo de la lente intraocular tras cirug&iacute;a refractiva    corneal</font></b></font></p>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'>&nbsp;</p>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><b><font face="Verdana, Arial, Helvetica, sans-serif" size="3">Principles    for the intraocular lens power calculation after corneal refractive surgery</font></b></p>  	    <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2"><b>&nbsp;</b></font></p>  	    <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2"><b>&nbsp;</b></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2"></font><font face="verdana" size="2"><b>Taim&iacute;    C&aacute;rdenas D&iacute;az, Michel Guerra Almaguer, Iv&aacute;n Hern&aacute;ndez    L&oacute;pez, Dunia Cruz Izquierdo, Eric Montero D&iacute;az, Ra&uacute;l Hern&aacute;ndez    Silva</b></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2"><b></b></font><font face="verdana" size="2">Instituto    Cubano de Oftalmolog&iacute;a "Ram&oacute;n Pando Ferrer". La Habana, Cuba.</font></p>  	     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p> <hr size="2" width="100%" align="center"> <font face="verdana" size="2"><b>RESUMEN</b></font>     <p><font face="verdana" size="2">Se estima que aproximadamente un mill&oacute;n    o m&aacute;s de pacientes se realizan cirug&iacute;a refractiva al a&ntilde;o.    Es por eso que con el envejecimiento son cada d&iacute;a m&aacute;s frecuentes    los pacientes con catarata, a quienes previamente se les ha efectuado cirug&iacute;a    refractiva. El c&aacute;lculo inexacto de la potencia di&oacute;ptrica de la    lente a implantar en la intervenci&oacute;n de estos es tambi&eacute;n un problema    de importancia creciente y con &eacute;l la sorpresa refractiva. Este es mucho    m&aacute;s complejo de lo normal, ya que existen dos fuentes de error: la incorrecta    predicci&oacute;n de la posici&oacute;n efectiva de la lente por parte de la    f&oacute;rmula y la determinaci&oacute;n err&oacute;nea de la potencia de la    c&oacute;rnea por parte de la queratometr&iacute;a. La correcci&oacute;n de    estos dos factores permitir&aacute; realizar un c&aacute;lculo correcto en estos    ojos. De ah&iacute; la motivaci&oacute;n para realizar una b&uacute;squeda actualizadas    de los &uacute;ltimos diez a&ntilde;os de diversos art&iacute;culos publicados,    con el objetivo de describir los principios para el c&aacute;lculo de la lente    intraocular tras cirug&iacute;a refractiva corneal. Se utiliz&oacute; la plataforma    Infomed, espec&iacute;ficamente la Biblioteca Virtual de Salud, con todos sus    buscadores.</font> </p>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:150%;text&#45;autospace:none'><font face="verdana" size="2"><b>Palabras    clave:</b> cirug&iacute;a refractiva corneal; poder corneal; c&aacute;lculo    de lente intraocular.</font></p>  	<hr size="2" width="100%" align="center"> <font face="verdana" size="2"><b>ABSTRACT</b></font>      <p style='margin&#45;bottom:12.0pt;text&#45;line&#45;height: normal;'><font face="Verdana, Arial, Helvetica, sans-serif" size="2">It    is considered that approximately one million or more patients undergo refractive    surgery every year. Due to aging, the number of patients with cataract, who    had previously undergone refractive surgery, is increasingly higher. The inaccurate    calculation of the dioptric power of the lens to be implanted is also a growing    significant problem and thus the refractive surprise. This is a much more complex    situation since two error sources exist: the incorrect prediction of the effective    position of the lens based on the formula and the wrong determination of the    corneal power through keratometry. The correction of these two factors will    allow making a suitable power calculation. Hence the motivation for updated    search of several articles published in the last ten years, with the objective    of describing the principles for intraocular lens power calculation after corneal    refractive surgery. The Infomed platform, mainly the Virtual Library of Health,    was fully used.    <br>   </font></p>     <p style='margin&#45;bottom:12.0pt;text&#45;line&#45;height: normal;'><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Key    words:</b> corneal refractive surgery; corneal power; intraocular lens power    calculation. </font></p>  	<hr size="2" width="100%" align="center">     <p style='margin&#45;bottom:12.0pt;line&#45;height:normal;'>    <br>       <br> </p>     ]]></body>
<body><![CDATA[<p style='margin&#45;bottom:12.0pt;line&#45;height:normal;'><font face="verdana" size="2"><b><font size="3">INTRODUCCI&Oacute;N</font></b></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2">Se    estima que aproximadamente un mill&oacute;n o m&aacute;s de pacientes se realizan    cirug&iacute;a refractiva al a&ntilde;o.<sup>1</sup> De ah&iacute; que con el    envejecimiento, cada d&iacute;a sean m&aacute;s frecuentes los pacientes con    catarata, a quienes previamente se les ha efectuado cirug&iacute;a refractiva.    El c&aacute;lculo de la lente intraocular (LIO) en pacientes intervenidos de    cirug&iacute;a queratorrefractiva &#45;queratotom&iacute;a radial (QR), <i>l&aacute;ser    assited in situ keratomileusis</i>, (LASIK) y <i>l&aacute;ser assisted sub&#45;epithelial    keratomileusis</i> (LASEK)&#45; es mucho m&aacute;s complejo de lo normal, dado    que los sujetos operados tienen en general expectativas y exigencias mayores    respecto a los resultados refractivos. Adem&aacute;s, el c&aacute;lculo inexacto    de la potencia di&oacute;ptrica de la LIO a implantar en la intervenci&oacute;n    de estos es un problema de importancia creciente<sup>2&#45;6</sup> y con &eacute;l    la sorpresa refractiva,<sup>7&#45;9</sup> lo que motiv&oacute; a realizar una    revisi&oacute;n bibliogr&aacute;fica con el prop&oacute;sito de describir los    principios para el c&aacute;lculo de la lente intraocular tras cirug&iacute;a    refractiva corneal<font size="3">.</font></font></p>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'>&nbsp;</p>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2"><b><font size="3">C&Aacute;LCULO    DE LA LENTE INTRAOCULAR</font></b></font></p>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2">El    proceso de c&aacute;lculo de la potencia de la LIO debe modificarse cuando se    practica en un ojo con cirug&iacute;a refractiva corneal previa, ya que existen    dos fuentes de error: la incorrecta predicci&oacute;n de la posici&oacute;n    efectiva de la lente (ELP) por parte de la f&oacute;rmula y la determinaci&oacute;n    err&oacute;nea de la potencia de la c&oacute;rnea por parte de la queratometr&iacute;a;    la correcci&oacute;n de estos dos factores permitir&aacute; realizar un c&aacute;lculo    correcto en estos ojos.<sup>10&#45;13</sup> La mayor&iacute;a de las f&oacute;rmulas    para el c&aacute;lculo de la LIO se basa en la posici&oacute;n de la lente con    respecto a la c&oacute;rnea, es decir, en la ELP, para aumentar su exactitud.    Para calcular la ELP se mide la profundidad de la c&aacute;mara anterior (Haigis,    Holladay II) o se estima esta (SRK/T, Hoffer Q, Holladay I). De esta manera,    si la queratometr&iacute;a no es exacta, se traslada este error al c&aacute;lculo    de la ELP.<sup>14</sup> Cualquier f&oacute;rmula te&oacute;rica de 3<sup>ra</sup>    generaci&oacute;n (SRK/T, Hoffer Q, Holladay I) realiza dos pasos: primero,    utiliza la longitud axial (LA) y la queratometr&iacute;a (K) para calcular la    profundidad de la c&aacute;mara anterior &#91;<i>anterior chamber depth</i>    (ACD)&#93;. Despu&eacute;s esta variable, junto con la LA y la K nuevamente,    se utilizan para calcular la potencia di&oacute;ptrica de la LIO. Si se considera    que en el primer paso se realiza una estimaci&oacute;n de la profundidad de    la c&aacute;mara anterior y que esta distancia anat&oacute;mica no cambia despu&eacute;s    de la cirug&iacute;a refractiva, parece obvio que utilizar un valor de K menor    que el original (el que resulta de la cirug&iacute;a refractiva) proporcionar&aacute;    una infravaloraci&oacute;n de la ELP y, por tanto, de la potencia de la LIO,    con la consiguiente sorpresa refractiva postoperatoria.<sup>7,15,16</sup></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal'><font face="verdana" size="2">Es    necesario se&ntilde;alar que no todas las f&oacute;rmulas se ven afectadas de    la misma manera. La Hoffer Q, al basar la predicci&oacute;n de la ELP en una    ecuaci&oacute;n curva, disminuye el efecto de acortamiento de la ELP en funci&oacute;n    de la K,<sup>45</sup> por lo que el error ser&aacute; menor que el cometido    por SRK/T y Holladay I. Es por eso que, al realizar un c&aacute;lculo normal    (no doble K) esta f&oacute;rmula es la menos hipermetropizante tal y como han    descrito algunos autores.<sup>17<i> </i></sup></font><font face="verdana" size="2"><i>Aramberri</i>    propone una modificaci&oacute;n en la f&oacute;rmula SRK/T en la cual la queratometr&iacute;a    preoperatoria (Kpre) se utiliza para estimar la ELP y la Kpost para calcular    el poder di&oacute;ptrico de la LIO (f&oacute;rmula doble&#45;K). Cualquier    f&oacute;rmula de 3<sup>ra</sup> generaci&oacute;n puede corregirse para que    utilice la Kpre para el c&aacute;lculo de ELP y la Kpost para el c&aacute;lculo    de la potencia de la LIO.<sup>18 </sup></font><font face="verdana" size="2">Una    importante conclusi&oacute;n ser&iacute;a que registrar la Kpre es cr&iacute;tico    para el c&aacute;lculo de la ELP. De hecho, solo en aquellos pacientes en los    que se disponga de la historia refractiva previa se podr&aacute; estimar la    ELP y utilizar una f&oacute;rmula de 3<sup>ra</sup> generaci&oacute;n con la    correcci&oacute;n doble&#45;K de <i>Aramberri.</i><sup>18</sup> Sin embargo,    el autor propone, en caso de no conocer la Kpre, utilizar un valor est&aacute;ndar    de 43,5 o 44 dioptr&iacute;as (D) para el c&aacute;lculo de la ELP.</font></p>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2">Un    modo simple de evitar el error de predicci&oacute;n de ELP es emplear la f&oacute;rmula    de Haigis, que no emplea la K como predictora de la ELP para validar el resultado.    En esta f&oacute;rmula &uacute;nicamente se introduce LA, ACD y Kpost. Se puede    obtener las constantes de la LIO de esta f&oacute;rmula en la p&aacute;gina    web de la Universidad de Wuerzburg.<sup>19</sup> El margen de error del que    se dispone en la predicci&oacute;n de la ELP es amplio, por lo que la mayor&iacute;a    de los investigadores coinciden en que la fuente de error fundamental es un    c&aacute;lculo incorrecto de la potencia corneal.</font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;punctuation&#45;wrap:simple;vertical&#45;align:baseline'><font face="verdana" size="2">La    cirug&iacute;a refractiva cambia la arquitectura de la c&oacute;rnea central,    por lo que los m&eacute;todos convencionales de medici&oacute;n sobrestiman    el poder corneal. La literatura actual sugiere que esta sobrestimaci&oacute;n    es de 14&#45;25 % despu&eacute;s de la cirug&iacute;a refractiva.<sup>8,15</sup>    La QR causa un aplanamiento proporcional de la curvatura anterior y posterior    de la c&oacute;rnea, sin alterar el &iacute;ndice de refracci&oacute;n; mientras    que la cirug&iacute;a fotoablativa modifica la relaci&oacute;n entre la cara    anterior y posterior de la c&oacute;rnea por la reducci&oacute;n del grosor    corneal, con el consiguiente cambio en el &iacute;ndice de refracci&oacute;n    corneal.<sup>20&#45;22</sup></font></p>  	    <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2">La potencia di&oacute;ptrica total de la c&oacute;rnea es la suma del poder de la cara anterior (lente convexa) y de la posterior (lente c&oacute;ncava). Tras la cirug&iacute;a fotoablativa se produce un cambio en la curvatura de la superficie anterior (se aplana en el caso de la cirug&iacute;a por miop&iacute;a y se curva tras la cirug&iacute;a por hipermetrop&iacute;a), mientras que no cambia la curvatura corneal posterior (o en todo caso el cambio es m&iacute;nimo). Esta alteraci&oacute;n de la relaci&oacute;n en la que se basa el valor del &iacute;ndice queratom&eacute;trico est&aacute;ndar (1,3375) conduce a una sobrestimaci&oacute;n de la potencia corneal total por parte del querat&oacute;metro.<sup>14</sup> Otros factores responsables de este error son: mayor asfericidad central en la c&oacute;rnea, cambio en el &iacute;ndice de refracci&oacute;n del estroma corneal y medici&oacute;n m&aacute;s perif&eacute;rica, ya que las miras se proyectan m&aacute;s perif&eacute;ricas en una c&oacute;rnea aplanada.<sup>7,22,23</sup></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal'><font face="verdana" size="2">La    queratometr&iacute;a tradicional y la simulada por la topograf&iacute;a estiman    la potencia corneal y miden los 3,2 mm centrales de la superficie anterior.    Para una c&oacute;rnea normal prolata esta asunci&oacute;n es adecuada; pero    tras cirug&iacute;a refractiva la relaci&oacute;n se altera. Por tanto, medir    la potencia corneal neta no es lo m&aacute;s indicado, ya que los valores utilizados    por los querat&oacute;metros y top&oacute;grafos no se cumplen en estos ojos.    La raz&oacute;n principal parece ser el cambio en la relaci&oacute;n entre los    radios de curvatura anterior y posterior de la c&oacute;rnea. Esto invalida    los valores de los distintos &iacute;ndices de refracci&oacute;n corneales (&iacute;ndice    de refracci&oacute;n est&aacute;ndar= 1,3375; SRK/T= 1,3333) que permite el    c&aacute;lculo del poder refractivo total de la c&oacute;rnea a partir del radio    de curvatura de la superficie anterior de la c&oacute;rnea en ojos no intervenidos.<sup>7,23</sup>    Un problema a&ntilde;adido es que no se puede cuantificar la desviaci&oacute;n    entre el cambio en la potencia refractiva de la c&oacute;rnea medido y el cambio    refractivo para determinar un factor de correcci&oacute;n. Aunque se han propuesto    valores medios (14&#45;25 % del cambio refractivo), la dispersi&oacute;n es    demasiado alta, probablemente como resultado de los cambios en la curvatura    corneal posterior.<sup>7,15,23</sup></font></p>  	     ]]></body>
<body><![CDATA[<p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal'><font face="verdana" size="2">Los    top&oacute;grafos de hendidura escaneada <i>(</i>orbscan<i>)</i> y <i>Scheimpflug</i>    (pentacam y galilei) pueden disminuir este error en la determinaci&oacute;n    de la potencia corneal total,<sup>24,25</sup> ya que miden tanto la superficie    anterior como la posterior. Constituyen herramientas muy &uacute;tiles en la    estimaci&oacute;n del poder corneal en pacientes con CR corneal previa, ya que    tienen incorporados en sus <i>softwares</i> aplicaciones para efectuar dicha    mensuraci&oacute;n.<sup>26</sup> El <i>True Net Power,</i> que trae incorporado    el pentacam, brinda la posibilidad de medir el poder real corneal usando para    la superficie anterior (&iacute;ndice de refracci&oacute;n corneal) el &iacute;ndice    de refracci&oacute;n del aire/radio de curvatura, y para la superficie posterior    (&iacute;ndice de refracci&oacute;n corneal) el &iacute;ndice de refracci&oacute;n    acuoso/radio de curvatura, lo que permite mayor exactitud en el c&aacute;lculo    de la LIO. Sin embargo, como se trata de un par&aacute;metro nuevo, integrarlo    a las f&oacute;rmulas que asumen valores K diferentes puede inducir errores    entre 0,50 a 1,75 D.<sup>27&#45;29</sup></font></p>  	    <p style='margin:0cm;margin&#45;bottom:.0001pt;text&#45;'><font face="verdana" size="2">&nbsp;</font></p>  	    <p style='margin:0cm;margin&#45;bottom:.0001pt;text&#45;'><font face="verdana" size="2">Otra de las aplicaciones novedosas que aporta el pentacam es el c&aacute;lculo de las K reales mediante el <i>Equivalent K&#45;readings</i> (EKR) en c&oacute;rneas modificadas por CR corneal calculadas a trav&eacute;s del programa <i>Holladay report.</i> Estos datos queratom&eacute;tricos se pueden aplicar directamente en las f&oacute;rmulas biom&eacute;tricas disponibles para el c&aacute;lculo de la LIO sin ajustes necesarios.<sup>30</sup> Este top&oacute;grafo puede predecir, adem&aacute;s, la K preoperatoria (Kpre), estimada con bastante exactitud al compararla con el valor de la K real del paciente antes de la CR corneal, valor que podr&iacute;a ser &uacute;til en la f&oacute;rmula de doble&#45;K de <i>Aramberri,</i> as&iacute; como en otros m&eacute;todos que requieran de este dato y que, por alguna raz&oacute;n, no est&eacute; disponible o no sea confiable.<sup>31&#45;35</sup></font></p>  	    <p style='margin:0cm;margin&#45;bottom:.0001pt;text&#45;'><font face="verdana" size="2">&nbsp;</font></p>  	     <p style='margin:0cm;margin&#45;bottom:.0001pt;text&#45;'><font face="verdana" size="2">El    orbscan proporciona un valor exacto del poder total de la c&oacute;rnea y eval&uacute;a    hasta 9 000 puntos, los promedia y brinda un valor representativo del poder    queratom&eacute;trico total. Se ha propuesto tambi&eacute;n utilizar las medidas    tomadas de los 2 y 4 mm centrales que proporciona el valor m&aacute;s plano    de la c&oacute;rnea y el programa <i>Mean Total Power,</i> que calcula la potencia    paraxial (funciona mejor cuando se analiza un &aacute;rea de 2 mm centrales    y se usa el mapa del poder promedio total). Hay que destacar que el orbscan    mide sistem&aacute;ticamente una curvatura m&aacute;s acentuada en la cara posterior    que el pentacam (potencia m&aacute;s negativa y, por tanto, potencia corneal    total m&aacute;s baja).<sup>36,37</sup> Los valores obtenidos con el orbscan    y el pentacam deben ser ajustados mediante la suma de un factor a un equivalente    del &iacute;ndice queratom&eacute;trico est&aacute;ndar K (1,3375): para el    <i>True Net Power</i> del pentacam ser&iacute;a 0,95 y 1,1 para el <i>Mean Total    Power</i> del <i>o</i>rbscan.<sup>26,30</sup></font></p>  	    <p style='margin:0cm;margin&#45;bottom:.0001pt;text&#45;'><font face="verdana" size="2">&nbsp;</font></p>  	     <p style='margin:0cm;margin&#45;bottom:.0001pt;text&#45;'><font face="verdana" size="2">El    Galilei consta de una c&aacute;mara central para capturar la imagen frontal    de los discos de Pl&aacute;cido y dos c&aacute;maras <i>Scheimpflug</i> que    analizan 122 000 puntos del segmento anterior del ojo. Este top&oacute;grafo    es capaz de medir los radios de curvatura corneal anterior y posterior. Dichas    mensuraciones son combinadas con los &iacute;ndices refractivos de la c&oacute;rnea,    del aire, del humor acuoso y de la paquimetr&iacute;a, y de esta forma brindan    el poder corneal real <i>(Central Average Power).</i><sup>16</sup> De manera    general, al realizar cirug&iacute;a queratorrefractiva, ya no son v&aacute;lidos    los valores de la queratometr&iacute;a, teniendo en cuenta tres factores:<sup>16</sup></font></p>  	     <blockquote>       <p><font face="verdana" size="2"><i>- Multifocalidad:</i> aumenta el rango de      los radios de curvatura corneal en la zona &oacute;ptica, y esto implica que      el valor queratom&eacute;trico de los tres mil&iacute;metros ya no sea representativo      del poder corneal m&aacute;s central.</font></p>       <p><font face="verdana" size="2"><i>- Asfericidad negativa: </i>la curvatura      corneal es m&aacute;s plana conforme se aproxima al &aacute;pex corneal, que      es lo contrario que ocurre en una c&oacute;rnea normal.</font></p>       ]]></body>
<body><![CDATA[<p><font face="verdana" size="2"><i>- Irregularidad corneal y astigmatismos      asim&eacute;tricos</i> (por descentramientos de la ablaci&oacute;n o por cicatrizaciones      asim&eacute;tricas): aunque son poco frecuentes, provocan aumentos focales      de la curvatura corneal que dificultan la realizaci&oacute;n de una queratometr&iacute;a      fiable.</font></p> </blockquote>     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;'><font face="verdana" size="2">Numerosos    m&eacute;todos se recogen en la literatura oftalmol&oacute;gica con el objetivo    de mejorar la estimaci&oacute;n del poder di&oacute;ptrico de la c&oacute;rnea    en aquellos ojos con CRC, pero en la actualidad no existe un m&eacute;todo &uacute;nico    aceptado por todos. Se han descrito para corregir la potencia de la c&oacute;rnea    los que necesitan la historia refractiva como son: MHC,<sup>38&#45;41</sup>    m&eacute;todo Koch&#45;Wang,<sup>20</sup> m&eacute;todo Speicher&#45;Seitz<sup>23</sup>    y el ajuste de &iacute;ndices refractivos: <i>Savini</i>,<sup>4,42</sup> <i>Camellin</i>,<sup>43</sup>    y <i>Jarade</i>,<sup>44</sup> as&iacute; como los que no requieren de esta informaci&oacute;n:    m&eacute;todo de la lente de contacto (MLC),<sup>45</sup> m&eacute;todo de Maloney&#45;Koch,<sup>46</sup>    m&eacute;todo Savini&#45;Barboni&#45;Zanini,<sup>47</sup> m&eacute;todo de Shammas<sup>48</sup>    y ajuste de &iacute;ndices refractivos: <i>Ferrara</i>,<sup>49</sup> Rosa,<sup>50</sup>    BESSt.<sup>7,42</sup> Tambi&eacute;n se recogen en la literatura m&eacute;todos    para corregir la LIO calculada. De igual manera los hay que demandan de la historia    refractiva como: doble&#45;K de Aramberri,<sup>18,26,51</sup> f&oacute;rmula    de Feiz&#45;Mannis,<sup>14,42</sup> m&eacute;todos de Latkany,<sup>52</sup>    m&eacute;todo de Masket<sup>47</sup> y m&eacute;todo de Wake&#45;Forest,<sup>47</sup>    y los que prescinden de ella como: Doble&#45;K de Aramberri (Kpre= 43,5 D),<sup>18,26,51</sup>    Ianchulev<sup>53</sup> y Mackool.<sup>54</sup></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2">El    c&aacute;lculo mediante trazado de rayos es una alternativa al empleo de f&oacute;rmulas    anal&iacute;ticas de vergencia que promete un cambio significativo en el c&aacute;lculo    en la determinaci&oacute;n de la LIO en los pr&oacute;ximos a&ntilde;os. En    ojos operados mediante cirug&iacute;a queratorrefractiva, el c&aacute;lculo    mediante trazado de rayos exacto permite valorar el efecto de la aberraci&oacute;n    esf&eacute;rica sobre la posici&oacute;n del plano de mejor enfoque, que puede    variar algunas dioptr&iacute;as respecto al plano paraxial en pupilas de tama&ntilde;o    medio&#45;grande.<sup>1,55,56</sup> Hay que tener en cuenta que en el c&aacute;lculo    por trazado es necesario el algoritmo de predicci&oacute;n de la posici&oacute;n    f&iacute;sica de la LIO dentro del ojo, y si el radio de curvatura corneal ha    participado en dicha predicci&oacute;n, habr&aacute; que ajustar nuevamente    el algoritmo.</font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal'><font face="verdana" size="2">Los    principios de trazado de rayos sugieren que el uso de este m&eacute;todo para    el c&aacute;lculo de LIO puede proporcionar resultados reproducibles m&aacute;s    precisos en comparaci&oacute;n con los m&eacute;todos queratom&eacute;tricos    alternativos existentes. La tecnolog&iacute;a de trazado de rayos se encuentra    actualmente disponible en muchos sistemas topogr&aacute;ficos, aunque los resultados    pueden mejorarse con la adici&oacute;n de programas computacionales externos    como Okulix (Oculix, Dortmund, Alemania). <i>Savini</i> y otros indican que    el trazado de rayos evita los problemas en casos con cirug&iacute;a refractiva    corneal previa.<sup>57</sup> El c&aacute;lculo del rayo refractado, tanto en    la superficie anterior como posterior, evita el uso del &iacute;ndice queratom&eacute;trico    est&aacute;ndar.</font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal'><font face="verdana" size="2">Por    &uacute;ltimo, se evitan errores de f&oacute;rmula, ya que la posici&oacute;n    efectiva de la lente se puede calcular sin el valor de la curvatura anterior.<sup>57</sup>    Hoffmann y otros sugirieron que, aunque la precisi&oacute;n de la predicci&oacute;n    de trazado de rayos se mantiene solo comparable a las f&oacute;rmulas de tercera    generaci&oacute;n, la precisi&oacute;n mejora en los ojos especiales aquellos    con longitud axial extrema o en pacientes con cirug&iacute;a refractiva previa.<sup>58</sup>    Los resultados obtenidos por <i>Savinni</i> y otros en trabajos recientes destacan    a&uacute;n m&aacute;s el potencial de la utilizaci&oacute;n de valores basados    en trazado de rayos.<sup>57,59,60</sup></font></p>  	     <p style='margin&#45;bottom:0cm;margin&#45;bottom:.0001pt;text&#45;line&#45;height:normal;text&#45;autospace:none'><font face="verdana" size="2">Consideramos    de gran importancia conocer los principios para el c&aacute;lculo de la lente    intraocular tras cirug&iacute;a refractiva corneal, ya que cada d&iacute;a son    m&aacute;s los pacientes con esta condici&oacute;n. Adem&aacute;s, la cirug&iacute;a    de catarata ha pasado a ser una cirug&iacute;a refractiva donde &#45;tanto el    cirujano como el paciente&#45; aspiran a lograr la emetrop&iacute;a posoperatoria,    es decir, la ausencia de defecto refractivo, y para esto es imprescindible un    adecuado c&aacute;lculo de la LIO. De nada sirve dominar una t&eacute;cnica    brillantemente, o utilizar LIO pleglables, si no se calcula adecuadamente su    potencia.</font></p>  	     <p style='text&#45;'><font face="verdana" size="2">    <br>       <br>   <b><font size="3">REFERENCIAS BIBLIOGR&Aacute;FICAS</font></b></font><font face="verdana" size="2">&nbsp;</font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">1. Prado A, Cama    JT, Sosa SP, Nava NG. C&oacute;mo evitar la sorpresa refractiva. C&aacute;lculo    del poder di&oacute;ptrico de lentes intraoculares en casos especiales. Rev    Mex Oftalmol. 2010;84(1):39-48.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">2. Savini G, Barboni    P, Zanini M. Correlation between attempted correction and keratometric refractive    index of the cornea after myopic exc&iacute;mer laser surgery. J Refract Surg.    2007;23(5):461-6.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">3. Kawamorita T,    Uozato H, Kamiya K, Leon Bax, Tsutsui K, Aizawa D, Shimizu K. Repeatability,    reproducibility and agreement characteristics of rotating Scheimpflug photography    and scanning-slit corneal topography for corneal power measurement. J Cataract    Refract Surg. 2009;35(1):127-33.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">4. Rosa N. Corneal    morphological changes after myopic excimer laser refractive surgery. Cornea.    2011;30(2):130-5.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">5. Rosa N. Analysis    of photoastigmatic keratectomy with the cross-cylinder ablation. Ind J Ophthalmol.    2012;60(4):283-7.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">6. Feiz V. Intraocular    lens power calculation after corneal refractive surgery. Middle East Afr J Ophthalmol.    2010;17(1):63-8.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">7. Borasio E, Stevens    E, Smith GT. Estimation of true corneal power after keratorefractive surgery    in eyes requiring cataract surgery. J Cataract Refract Surg. 2006;32(12):2004-14.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">8. Masket S, Masket    SE. Simple regressi&oacute;n formula for intraocular lens power adjustment in    eyes requiring cataract surgery after exc&iacute;mer laser photoablation. J    Cataract Refract Surg. 2006;32(3):430-4.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">9. De Bernardo    M, Capasso L, Rosa N. Algorithm for the estimation of the corneal power in eyes    with previous myopic laser refractive surgery. Cornea. 2014;33(6):2.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">10. Rosa N, de    Bernardo M, Lanza M. Axial eye length evaluation before and after hyperopic    photorefractive keratectomy. J Refract Surg. 2013;29(2):80.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">11. De Bernardo    M, Rosa N. Diehl-Miller nomogram for intraocular lens power calculation. J Catarat    Refract Surg. 2013;39(11):1791.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">12. Wang L, Shirayama    M, Ma XJ, Kohnen T, Koch DD. Optimizing intraocular lens power calculations    in eyes with axial lengths above 25.0 mm. J Cataract Refract Surg. 2011;37(11):2018-27.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">13. Hill WE. IOL    power calculations after keratorefractive surgery. Cataract &amp; Refractive    Surgery Today. 2008;(Sup.):1-3.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">14. Mesa JC, Porta    J, Cbir&oacute; I, Am&iacute;as V, Rouras A. C&aacute;lculo biom&eacute;trico    tras cirug&iacute;a refractiva. Superficie ocular. Rev Lab Thea. 2010;37(3):747-8.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">15. Mesa JC, Mart&iacute;    T, Arruga J. C&aacute;lculo de la potencia de la lente intraocular en situaciones    especiales. Annals d'Oftalmolog&iacute;a. 2008;16(2):68-89.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">16. Ortega JG,    Freidell H, Kwitko S, Lu LW, Zacharias W, S&aacute;chez JC. Cu&aacute;l es la    t&eacute;cnica de elecci&oacute;n para el c&aacute;lculo del LIO poscirug&iacute;a    refractiva. Noticiero ALACCSA-R/Diciembre 2011 [citado 10 enero 2012]. Disponible    en: <a href="http://www.alaccsa.com/noticiero_diciembre_11.htm" target="_blank">http://www.alaccsa.com/noticiero_diciembre_11.htm</a></font><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">17. Savini G, Hoffer    J, Zanini M. IOL power calculations after LASIK and PRK. Cataract &amp; Refractive    Surgery Today. 2007 [citado 12 diciembre 2013]. Disponible en: <a href="http://www.bmctoday.net/crstodayeurope/2007/04/article.asp?f=0407_09.php" target="_blank">http://www.bmctoday.net/crstodayeurope/2007/04/article.asp?f=0407_09.php</a></font><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">18. Aramberri J.    Intraocular lens power calculation after corneal refractive surgery: double-K    method. J Cataract Refract Surg. 2003;29(11):2063-8.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">19. Haigis W. Intraocular    lens calculation after refractive surgery for myopia: Haigis-L formula. J Catar    Refract Surg. 2008;34(10):1658-63.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">20. Koch D, Wang    L. Calculating IOL power in eyes that have had refractive surgery. J Cataract    Refract Surgery. 2003;29(11):2039-42.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">21. Hamed A, Wang    L, Misra M, Koch C. A comparative analyisis of five methods of determining corneal    refractive power in eyes that have undergone myopic laser in situ keratomileusis.    Ophthalmology. 2002;109(4):651-8.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">22. Jim&eacute;nez    G. C&aacute;lculo de lente intraocular en pacientes con cirug&iacute;a refractiva    previa. Rev Mex Oftalmol. 2007;81(3):134-7.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">23. Speicher C,    Seitz J. Cataract surgery in patients with prior refractive surgery. Current    opinion. Ophthalmoly. 2003;14(1):44-53.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">24. Gonz&aacute;lez    A, Ortega L, P&eacute;rez E. Astigmatismo inducido en la cirug&iacute;a de catarata    por t&eacute;cnica de facoemulsificaci&oacute;n. Rev Cubana Oftalmol. 2011;24(1):30-9.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">25. Ballate EM.    Posici&oacute;n efectiva cl&iacute;nica de la lente intraocular y otras variables    asociadas al defecto esf&eacute;rico residual. Rev Cubana Oftalmol. 2011;4(2):239-47.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">26. Aramberri J.    C&aacute;lculo de la lente intraocular tras cirug&iacute;a refractiva corneal.    En: Ali&oacute; J, Rodr&iacute;guez-Prats J, editor. Buscando la excelencia    en la cirug&iacute;a de la catarata. Barcelona: Editorial Glosa; 2006. p. 179-91.        </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">27. Jain R, Dilraj    G, Grewal SPS. Repeatability of corneal parameters with Pentacam after laser    in situ keratomileusis. Indian J Ophthalmol. 2007;55(5):341-7.     </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">28. Morcillo Laiz    R, Mu&ntilde;oz Negrete F, Dur&aacute;n Poveda S. La c&aacute;mara Scheimpflug    rotacional Pentacam. Actualizaciones tecnol&oacute;gicas en Oftalmolog&iacute;a.    Studium Ophthalmologicum. 2006 [citado 10 de noviembre de 2011];24(4). Disponible    en: <a href="http://www.oftalmo.com/studium/studium2006/stud06-4/06d-04.htm" target="_blank">http://www.oftalmo.com/studium/studium2006/stud06-4/06d-04.htm</a>    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">29. Cuan Aguilar    Y, P&eacute;rez Candelaria E, Montero D&iacute;az E, Santiesteban Garc&iacute;a    I, Ortega D&iacute;az L, C&aacute;rdenas D&iacute;az T. Utilidad del Pentacam    para medir el poder corneal despu&eacute;s de cirug&iacute;a refractiva con    exc&iacute;mer l&aacute;ser. Rev Cubana Oftalmol. 2010;23(Supl.)1:513-21.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">30. Jim&eacute;nez    Matus G, Arroyo Mu&ntilde;oz L, Perdiz Calvo L, Velasco Ramos R, Lozano Alcazar    J. C&aacute;lculo de lente intraocular en pacientes con cirug&iacute;a refractiva    previa. Rev Mex Oftalmol. 2007;81(3):134-7.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">31. Dom&iacute;nguez    M. Beneficios del sistema Scheimpflug en glaucoma. Rev Cubana Oftalmol. 2012    [citado 7 de noviembre de 2014];25(Supl.1). Disponible en: <a href="http://scielo.sld.cu/scielo.php?script=sci_arttext&pid=S0864-21762012000300011&lng=es&nrm=iso&tlng=es" target="_blank">http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762012000300011&amp;lng=es&amp;nrm=iso&amp;tlng=es</a></font><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">32. Miranda I.    Comparaci&oacute;n de los valores del espesor corneal central seg&uacute;n los    equipos Lenstar, Galilei y Pentacam. Rev Cubana Oftalmol. 2012;25(1):65-71.    <br>       <!-- ref --><br>   33. Hern&aacute;ndez I. Cuantificaci&oacute;n objetiva de la opacidad de la    c&aacute;psula posterior mediante tomogramas Scheimpflug del Pentacam. Rev Cubana    Oftalmol. 2011;24(2):208-19.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">34. Tirado OM,    Hern&aacute;ndez A. Top&oacute;grafos de elevaci&oacute;n en el diagn&oacute;stico    del queratocono. Rev Cubana Oftalmol. 2011;24(2):364-73.     </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">35. Shammas HJ,    Hoffer KJ, Shammas MC. Scheimpflug photography keratometry readings for routine    intraocular lens power calculation. J Cataract Refract Surg. 2009;35(2):330-4.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">36. Ortega JJ.    C&aacute;lculo del lente Intraocular despu&eacute;s de cirug&iacute;a refractiva.    En: Centuri&oacute;n V, editor. El Libro del Cristalino de las Am&eacute;ricas.    Brasil: Livraria Santos; 2007. p. 119-22.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">37. Holladay JT.    Measuring corneal power after corneal refractive surgery. Cataract Refractive    Surgery Today. 2006 [citado noviembre 2011]. Disponible en: <a href="http://bmctoday.net/crstoday/pdfs/1106_supp.pdf" target="_blank">http://bmctoday.net/crstoday/pdfs/1106_supp.pdf</a>    </font><!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">38. Savini G, Barboni    P, Profazio V, Zanini M, Hoffer KJ. Corneal power measurements with the top&oacute;grafo    Pentacam Scheimpflug camera after myopic exc&iacute;mer laser surgery. J Cataract    Refract Surg. 2008;34(5):809-13.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">39. Saiki M. A    new central-peripheral corneal curvature method for intraocular lens power calculation    after excimer laser refractive surgery. Acta Ophthalmol. 2013;91(2):e133-9.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">40. Rosa N, De    Bernardo M, Borrelli M, Lanza M. New factor to improve reliability of the clinical    history method for intraocular lens power calculation after refractive surgery.    J Cataract Refract Surg. 2010;36(12):2123-8.    </font></p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">41. De Bernardo.    IOL power calculation after corneal refractive surgery. BioMed Res Internat.    2014 [citado 20 de diciembre de 2015]21. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4129218/" target="_blank">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4129218/</a></font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">42. Mesa JC, Ruiz    Cl. El c&aacute;lculo de la lente intraocular tras cirug&iacute;a fotorrefractiva    corneal. Revisi&oacute;n de la literatura. Arch Soc Esp Oftalmol. 2009;84(6):283-92.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">43. Camellin M,    Calossi A. A new formula for intraocular lens power calculation after refractive    corneal surgery. J Refract Surg. 2006;22(2):187-99.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">44. Jarade EF,    Abinader FC, Tabbara KF. Intraocular lens power calculation following LASIK.    Invest Ophthalmol Vis Sci. 2002;43:41-3.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">45. Haigis W. Corneal    power alter refractive surgery for myopia: contact lens method. J Cataract Refract    Surgery. 2003;29(7):1397-411.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">46. Koch DD, Liu    JF, Hyde LL, Rock RL, Emery JM. Refractive complications of cataract surgery    after radial keratotomy. Am J Ophthalmol. 1989;108(6):676-82.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">47. P&eacute;rez    E. M&eacute;todos para determinar el poder de la lente intraocular despu&eacute;s    de cirug&iacute;a refractiva corneal. Rev Cubana Oftalmol. 2013 [citado 12 de    diciembre de 2013];26(1). Disponible en: <a href="http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/178/html" target="_blank">http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/178/html</a>    <br>       <!-- ref --><br>   48. Shammas H, Shamas M, Garabet A, Kim J, Shammas A, LaBree L. Correcting the    corneal power measurements for intraocular lens power calculations after myopic    laser in situ keratomileusis. Am J Ophthalmol. 2003;136(3):426-32.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">49. Ferrara G,    Cennamo G, Marotta G. New formula to calculate IOL power. J Cataract Refract    Surg. 2004;20(5):465-71.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">50. Rosa N, Capaso    L, Romano A. A new method of calculating intraocular lens power after photorefractive    keratectomy. J Cataract Refract Surg. 2002;18(6):720-4.    <br>       <!-- ref --><br>   51. Saiki M, et al. Modi?ed double-K method for intraocular lens power calculation    after excimer laser corneal refractive surgery. J Cataract Refract Surg. 2013;39(4):556-62.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">52. Latkany R,    Chokshi A, Speader M, Abramson I, Solowitz B. Intraocular lens calculations    after refractive surgery. J Cataract Refract Surg. 2005;31(3):562-70.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">53. Ianchulev T,    Salz J, Hoffer K, Albini T, Hsu H, Labree L. Intraoperatory optical biometry    for intraocular lens power estimation without axial length and keratometry measurements.    J Cataract Refract Surg. 2005;31(8):1530-6.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">54. Mackool RJ,    Wilson K, Mackool R. Intraocular lens power calculation after laser in situ    keratomieleusis: aphakic refraction technique. J Cataract Refract Surg. 2006;32(3):435-7.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">55. Minami K. Ray-tracing    intraocular lens power calculation using anterior segment optical coherence    tomography measurements. J Cataract Refract Surg. 2012;38(10):1758-63.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">56. Saiki M. Ray    tracing software for intraocular lens power calculation after corneal excimer    laser surgery. Jap J Ophthalmol. 2014;58(3):276-81.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">57. Savini G, Bedei    A, Barboni P, Ducoli P, Hoffer KJ. Intraocular lens power calculation by ray    tracing after myopic excimer laser surgery. Am J Ophthalmol. 2014;157(1):150-3.    <br>       <!-- ref --><br>   58. Hoffmann P, Wahl J, Preussner PR. Accuracy of intraocular lens calculation    with ray tracing. J Refract Surg. 2012;28(9):650-5.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">59. Savini G, Hoffer    KJ, Carbonelli M, Barboni P. Scheimpflug analysis of corneal power changes after    myopic excimer laser surgery. J Cataract Refract Surg. 2013;39(4):605-10.    </font></p>     <!-- ref --><p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">60. Savini G, Calossi    A, Camellin M, Carones F, Fantozzi M, Hoffer KJ. Corneal ray tracing versus    simulated keratometry for estimating corneal power changes after excimer laser    surgery. J Cataract Refract Surg. 2014;40(7):1109-15.    <br>       <br>   </font></p>     <p>    <br>       <br> </p>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Recibido: 26 de    octubre de 2015.    <br>   Aprobado: 14 de diciembre de 2015.</font></p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font face="verdana" size="2"><i>Taim&iacute; C&aacute;rdenas D&iacute;az</i></font><i>.</i>    <font face="Verdana, Arial, Helvetica, sans-serif" size="2">Instituto Cubano    de Oftalmolog&iacute;a &quot;Ram&oacute;n Pando Ferrer&quot;. Ave. 76 No. 3104    entre 31 y 41 Marianao, La Habana, Cuba. Correo electr&oacute;nico: <a href="mailto:taimicar@infomed.sld.cu">taimicar@infomed.sld.cu</a>    </font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Prado]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cama]]></surname>
<given-names><![CDATA[JT]]></given-names>
</name>
<name>
<surname><![CDATA[Sosa]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
<name>
<surname><![CDATA[Nava]]></surname>
<given-names><![CDATA[NG]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cómo evitar la sorpresa refractivaCálculo del poder dióptrico de lentes intraoculares en casos especiales]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>2010</year>
<volume>84</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>39-48</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Barboni]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Zanini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correlation between attempted correction and keratometric refractive index of the cornea after myopic excímer laser surgery]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2007</year>
<volume>23</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>461-6</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kawamorita]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Uozato]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kamiya]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Leon Bax]]></surname>
</name>
<name>
<surname><![CDATA[Tsutsui]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Aizawa]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Shimizu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Repeatability, reproducibility and agreement characteristics of rotating Scheimpflug photography and scanning-slit corneal topography for corneal power measurement]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2009</year>
<volume>35</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>127-33</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal morphological changes after myopic excimer laser refractive surgery]]></article-title>
<source><![CDATA[Cornea]]></source>
<year>2011</year>
<volume>30</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>130-5</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of photoastigmatic keratectomy with the cross-cylinder ablation]]></article-title>
<source><![CDATA[Ind J Ophthalmol]]></source>
<year>2012</year>
<volume>60</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>283-7</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feiz]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation after corneal refractive surgery]]></article-title>
<source><![CDATA[Middle East Afr J Ophthalmol]]></source>
<year>2010</year>
<volume>17</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>63-8</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Borasio]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Stevens]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[GT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>2004-14</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Masket]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Masket]]></surname>
<given-names><![CDATA[SE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simple regressión formula for intraocular lens power adjustment in eyes requiring cataract surgery after excímer laser photoablation]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>430-4</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Capasso]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Algorithm for the estimation of the corneal power in eyes with previous myopic laser refractive surgery]]></article-title>
<source><![CDATA[Cornea]]></source>
<year>2014</year>
<volume>33</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>2</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[de Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Lanza]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Axial eye length evaluation before and after hyperopic photorefractive keratectomy]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2013</year>
<volume>29</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>80</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Diehl-Miller nomogram for intraocular lens power calculation]]></article-title>
<source><![CDATA[J Catarat Refract Surg]]></source>
<year>2013</year>
<volume>39</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1791</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Shirayama]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[XJ]]></given-names>
</name>
<name>
<surname><![CDATA[Kohnen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optimizing intraocular lens power calculations in eyes with axial lengths above 250 mm]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2011</year>
<volume>37</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2018-27</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hill]]></surname>
<given-names><![CDATA[WE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[IOL power calculations after keratorefractive surgery]]></article-title>
<source><![CDATA[Cataract / Refractive Surgery Today]]></source>
<year>2008</year>
<numero>^sSup</numero>
<issue>^sSup</issue>
<supplement>Sup</supplement>
<page-range>1-3</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mesa]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Porta]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Cbiró]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Amías]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Rouras]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo biométrico tras cirugía refractivaSuperficie ocular]]></article-title>
<source><![CDATA[Rev Lab Thea]]></source>
<year>2010</year>
<volume>37</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>747-8</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mesa]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Martí]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Arruga]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de la potencia de la lente intraocular en situaciones especiales]]></article-title>
<source><![CDATA[Annals d'Oftalmología]]></source>
<year>2008</year>
<volume>16</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>68-89</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Freidell]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kwitko]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Lu]]></surname>
<given-names><![CDATA[LW]]></given-names>
</name>
<name>
<surname><![CDATA[Zacharias]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Sáchez]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<source><![CDATA[Cuál es la técnica de elección para el cálculo del LIO poscirugía refractiva]]></source>
<year></year>
<publisher-name><![CDATA[Noticiero ALACCSA-R/Diciembre 2011]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Zanini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[IOL power calculations after LASIK and PRK. Cataract / Refractive Surgery Today]]></source>
<year>2007</year>
</nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aramberri]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation after corneal refractive surgery: double-K method]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2003</year>
<volume>29</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2063-8</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haigis]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula]]></article-title>
<source><![CDATA[J Catar Refract Surg]]></source>
<year>2008</year>
<volume>34</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1658-63</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Calculating IOL power in eyes that have had refractive surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surgery]]></source>
<year>2003</year>
<volume>29</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2039-42</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hamed]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Misra]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparative analyisis of five methods of determining corneal refractive power in eyes that have undergone myopic laser in situ keratomileusis]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2002</year>
<volume>109</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>651-8</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiménez]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de lente intraocular en pacientes con cirugía refractiva previa]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>2007</year>
<volume>81</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>134-7</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Speicher]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Seitz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Cataract surgery in patients with prior refractive surgeryCurrent opinion]]></article-title>
<source><![CDATA[Ophthalmoly]]></source>
<year>2003</year>
<volume>14</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>44-53</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Astigmatismo inducido en la cirugía de catarata por técnica de facoemulsificación]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2011</year>
<volume>24</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>30-9</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ballate]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Posición efectiva clínica de la lente intraocular y otras variables asociadas al defecto esférico residual]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2011</year>
<volume>4</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>239-47</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aramberri]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de la lente intraocular tras cirugía refractiva corneal]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Alió]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez-Prats]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Buscando la excelencia en la cirugía de la catarata]]></source>
<year>2006</year>
<page-range>179-91</page-range><publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Glosa]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jain]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Dilraj]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Grewal]]></surname>
<given-names><![CDATA[SPS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Repeatability of corneal parameters with Pentacam after laser in situ keratomileusis]]></article-title>
<source><![CDATA[Indian J Ophthalmol]]></source>
<year>2007</year>
<volume>55</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>341-7</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morcillo Laiz]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz Negrete]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Durán Poveda]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La cámara Scheimpflug rotacional Pentacam. Actualizaciones tecnológicas en Oftalmología]]></article-title>
<source><![CDATA[Studium Ophthalmologicum]]></source>
<year>2006</year>
<volume>24</volume>
<numero>4</numero>
<issue>4</issue>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cuan Aguilar]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez Candelaria]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Montero Díaz]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Santiesteban García]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Ortega Díaz]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Cárdenas Díaz]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Utilidad del Pentacam para medir el poder corneal después de cirugía refractiva con excímer láser]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2010</year>
<volume>23</volume>
<numero>^sSupl1</numero>
<issue>^sSupl1</issue>
<supplement>Supl1</supplement>
<page-range>513-21</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiménez Matus]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Arroyo Muñoz]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Perdiz Calvo]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Velasco Ramos]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Lozano Alcazar]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo de lente intraocular en pacientes con cirugía refractiva previa]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>2007</year>
<volume>81</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>134-7</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Domínguez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Beneficios del sistema Scheimpflug en glaucoma]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2012</year>
<volume>25</volume>
<numero>^sSupl.1</numero>
<issue>^sSupl.1</issue>
<supplement>Supl.1</supplement>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Miranda]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Comparación de los valores del espesor corneal central según los equipos Lenstar, Galilei y Pentacam]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2012</year>
<volume>25</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>65-71</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cuantificación objetiva de la opacidad de la cápsula posterior mediante tomogramas Scheimpflug del Pentacam]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2011</year>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>208-19</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tirado]]></surname>
<given-names><![CDATA[OM]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Topógrafos de elevación en el diagnóstico del queratocono]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2011</year>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>364-73</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[HJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Scheimpflug photography keratometry readings for routine intraocular lens power calculation]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2009</year>
<volume>35</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>330-4</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ortega]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Cálculo del lente Intraocular después de cirugía refractiva]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Centurión]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<source><![CDATA[El Libro del Cristalino de las Américas]]></source>
<year>2007</year>
<page-range>119-22</page-range><publisher-name><![CDATA[Livraria Santos]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holladay]]></surname>
<given-names><![CDATA[JT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Measuring corneal power after corneal refractive surgery]]></article-title>
<source><![CDATA[Cataract Refractive Surgery Today]]></source>
<year>2006</year>
</nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Barboni]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Profazio]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Zanini]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal power measurements with the topógrafo Pentacam Scheimpflug camera after myopic excímer laser surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2008</year>
<volume>34</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>809-13</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saiki]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new central-peripheral corneal curvature method for intraocular lens power calculation after excimer laser refractive surgery]]></article-title>
<source><![CDATA[Acta Ophthalmol]]></source>
<year>2013</year>
<volume>91</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>e133-9</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[De Bernardo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Borrelli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Lanza]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New factor to improve reliability of the clinical history method for intraocular lens power calculation after refractive surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2010</year>
<volume>36</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>2123-8</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[De]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[IOL power calculation after corneal refractive surgery]]></article-title>
<source><![CDATA[BioMed Res]]></source>
<year>2014</year>
<page-range>21</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mesa]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Ruiz Cl]]></surname>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[El cálculo de la lente intraocular tras cirugía fotorrefractiva cornealRevisión de la literatura]]></article-title>
<source><![CDATA[Arch Soc Esp Oftalmol]]></source>
<year>2009</year>
<volume>84</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>283-92</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Camellin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Calossi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new formula for intraocular lens power calculation after refractive corneal surgery]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2006</year>
<volume>22</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>187-99</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jarade]]></surname>
<given-names><![CDATA[EF]]></given-names>
</name>
<name>
<surname><![CDATA[Abinader]]></surname>
<given-names><![CDATA[FC]]></given-names>
</name>
<name>
<surname><![CDATA[Tabbara]]></surname>
<given-names><![CDATA[KF]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation following LASIK]]></article-title>
<source><![CDATA[Invest Ophthalmol Vis Sci]]></source>
<year>2002</year>
<volume>43</volume>
<page-range>41-3</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Haigis]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal power alter refractive surgery for myopia: contact lens method]]></article-title>
<source><![CDATA[J Cataract Refract Surgery]]></source>
<year>2003</year>
<volume>29</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1397-411</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Koch]]></surname>
<given-names><![CDATA[DD]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[JF]]></given-names>
</name>
<name>
<surname><![CDATA[Hyde]]></surname>
<given-names><![CDATA[LL]]></given-names>
</name>
<name>
<surname><![CDATA[Rock]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Emery]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Refractive complications of cataract surgery after radial keratotomy]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>1989</year>
<volume>108</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>676-82</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pérez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Métodos para determinar el poder de la lente intraocular después de cirugía refractiva corneal]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2013</year>
<volume>26</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Shamas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Garabet]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Shammas]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[LaBree]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correcting the corneal power measurements for intraocular lens power calculations after myopic laser in situ keratomileusis]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2003</year>
<volume>136</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>426-32</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ferrara]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Cennamo]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Marotta]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New formula to calculate IOL power]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2004</year>
<volume>20</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>465-71</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rosa]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Capaso]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Romano]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A new method of calculating intraocular lens power after photorefractive keratectomy]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2002</year>
<volume>18</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>720-4</page-range></nlm-citation>
</ref>
<ref id="B51">
<label>51</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saiki]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Modied double-K method for intraocular lens power calculation after excimer laser corneal refractive surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2013</year>
<volume>39</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>556-62</page-range></nlm-citation>
</ref>
<ref id="B52">
<label>52</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Latkany]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Chokshi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Speader]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Abramson]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Solowitz]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens calculations after refractive surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2005</year>
<volume>31</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>562-70</page-range></nlm-citation>
</ref>
<ref id="B53">
<label>53</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ianchulev]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Salz]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Albini]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hsu]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Labree]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraoperatory optical biometry for intraocular lens power estimation without axial length and keratometry measurements]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2005</year>
<volume>31</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1530-6</page-range></nlm-citation>
</ref>
<ref id="B54">
<label>54</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mackool]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
<name>
<surname><![CDATA[Wilson]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Mackool]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation after laser in situ keratomieleusis: aphakic refraction technique]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2006</year>
<volume>32</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>435-7</page-range></nlm-citation>
</ref>
<ref id="B55">
<label>55</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Minami]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ray-tracing intraocular lens power calculation using anterior segment optical coherence tomography measurements]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2012</year>
<volume>38</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1758-63</page-range></nlm-citation>
</ref>
<ref id="B56">
<label>56</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Saiki]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ray tracing software for intraocular lens power calculation after corneal excimer laser surgery]]></article-title>
<source><![CDATA[Jap J Ophthalmol]]></source>
<year>2014</year>
<volume>58</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>276-81</page-range></nlm-citation>
</ref>
<ref id="B57">
<label>57</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Bedei]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Barboni]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Ducoli]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Intraocular lens power calculation by ray tracing after myopic excimer laser surgery]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2014</year>
<volume>157</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>150-3</page-range></nlm-citation>
</ref>
<ref id="B58">
<label>58</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hoffmann]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Wahl]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Preussner]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Accuracy of intraocular lens calculation with ray tracing]]></article-title>
<source><![CDATA[J Refract Surg]]></source>
<year>2012</year>
<volume>28</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>650-5</page-range></nlm-citation>
</ref>
<ref id="B59">
<label>59</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
<name>
<surname><![CDATA[Carbonelli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Barboni]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Scheimpflug analysis of corneal power changes after myopic excimer laser surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2013</year>
<volume>39</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>605-10</page-range></nlm-citation>
</ref>
<ref id="B60">
<label>60</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Savini]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Calossi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Camellin]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Carones]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Fantozzi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hoffer]]></surname>
<given-names><![CDATA[KJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Corneal ray tracing versus simulated keratometry for estimating corneal power changes after excimer laser surgery]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2014</year>
<volume>40</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>1109-15</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
