<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-2176</journal-id>
<journal-title><![CDATA[Revista Cubana de Oftalmología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Oftalmol]]></abbrev-journal-title>
<issn>0864-2176</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-21762018000200013</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Corrección de la alta miopía con implante de lente fáquica ACR-128]]></article-title>
<article-title xml:lang="en"><![CDATA[Correction of high myopia with ACR-128 phakic lens implantation]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cárdenas Díaz]]></surname>
<given-names><![CDATA[Taimi]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Valdés González]]></surname>
<given-names><![CDATA[Gidelvis]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Sánchez Acosta]]></surname>
<given-names><![CDATA[Lizet]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fumero González]]></surname>
<given-names><![CDATA[Francisco Y]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cuan Aguilar]]></surname>
<given-names><![CDATA[Yoriel]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Montero Díaz]]></surname>
<given-names><![CDATA[Eric]]></given-names>
</name>
<xref ref-type="aff" rid="A1"/>
</contrib>
</contrib-group>
<aff id="AA1">
<institution><![CDATA[,Instituto Cubano de Oftalmología Ramón Pando Ferrer  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2018</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2018</year>
</pub-date>
<volume>31</volume>
<numero>2</numero>
<fpage>1</fpage>
<lpage>10</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762018000200013&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-21762018000200013&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-21762018000200013&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La alta miopía es aquella igual o mayor a -6 dioptrías esféricas, no en función de la curvatura corneal elevada, como es el caso del queratocono, ni por la esclerosis del cristalino que ocurre en etapas preseniles, sino en dependencia de la longitud axial mayor de 25,5 o 26,0 mm. La corrección óptica de estos defectos altos es difícil, ya que es frecuente que los pacientes se sientan incómodos con el uso de gafas, pues no obtienen una buena calidad de visión, y con el fin de mejorarla se han desarrollado distintos procedimientos quirúrgicos. Se presenta una paciente de 26 años de edad con miopía elevada, quien no se adapta a los lentes de contacto y no desea continuar con los espejuelos; no es candidata a la cirugía refractiva corneal. Se le implantaron lentes fáquicas ACR IOL-128 (Soleko, Italia) sin complicaciones. El equivalente esférico preoperatorio -11,5 y -6 dioptrías disminuyó a -1,00 y -0,5 respectivamente, y la agudeza visual sin cristales de cuenta dedos y 0,1 a 0,8 y 0,9 respectivamente. Con este caso se evidencia que las lentes fáquicas son una opción con buenos resultados en la corrección de la alta miopía.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The high myopia, by definition, is that equal or bigger to -6 spherical dioptrías; not in function of the bend high corneal, like it is the case of the queratocono, neither for the sclerosis of the crystalline lens that happens in stages preseniles, but in dependence of the axial longitude bigger than 25,5 or 26,0 mm. The optic correction of these high defects is difficult, since it is frequent that the patients feel uncomfortable with the glasses use, because they don't obtain a good quality of vision and with the purpose of improving it, different surgical procedures have been developed. Young patient 26 years old is presented with high myopia that doesn't adapt to the contact eyeglasseses and she doesn't want to continue with the espejuelos, she is not candidate to surgery refractive corneal and she is implanted eyeglasseses fáquica ACR IOL-128 (Soleko, Italy) without complications. The equivalent spherical preoperatorio -11,5 and -6 dioptrías diminish at -1,00 and - 0,5 respectively and the visual sharpness without glasses of bill fingers and 0,1 at 0,8 and 0,9 respectively. With this case it is evidenced that the lenses fáquicas are an option with good results in the correction of the high myopia.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[miopía alta]]></kwd>
<kwd lng="es"><![CDATA[lente fáquica ACR 128]]></kwd>
<kwd lng="es"><![CDATA[lentes intraoculares]]></kwd>
<kwd lng="en"><![CDATA[high myopia]]></kwd>
<kwd lng="en"><![CDATA[ACR 128 phakic lens]]></kwd>
<kwd lng="en"><![CDATA[intraocular lenses]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>PRESENTACI&#211;N    DE CASO</b> </font></p>     <p align="right">&nbsp;</p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="4">Correcci&#243;n    de la alta miop&#237;a con implante de lente f&#225;quica ACR-128</font></b></font></p>     <p align="left">&nbsp;</p>     <p align="left"><b><font size="3" face="Verdana, Arial, Helvetica, sans-serif">Correction    of high myopia with ACR-128 phakic lens implantation</font></b></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Taimi    C&#225;rdenas D&#237;az, Gidelvis Vald&#233;s Gonz&#225;lez, Lizet S&#225;nchez    Acosta, Francisco Y. Fumero Gonz&#225;lez, Yoriel Cuan Aguilar, Eric Montero    D&#237;az</b></font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Instituto    Cubano de Oftalmolog&#237;a &quot;Ram&#243;n Pando Ferrer&quot;. La Habana,    Cuba.</font></p> <hr> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>RESUMEN <br/> <br/> </b></font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">La alta  miop&#237;a es aquella igual o mayor a -6 dioptr&#237;as esf&#233;ricas, no en  funci&#243;n de la curvatura corneal elevada, como es el caso del queratocono,  ni por la esclerosis del cristalino que ocurre en etapas preseniles, sino en dependencia  de la longitud axial mayor de 25,5 o 26,0 mm. La correcci&#243;n &#243;ptica de  estos defectos altos es dif&#237;cil, ya que es frecuente que los pacientes se  sientan inc&#243;modos con el uso de gafas, pues no obtienen una buena calidad  de visi&#243;n, y con el fin de mejorarla se han desarrollado distintos procedimientos  quir&#250;rgicos. Se presenta una paciente de 26 a&#241;os de edad con miop&#237;a  elevada, quien no se adapta a los lentes de contacto y no desea continuar con  los espejuelos; no es candidata a la cirug&#237;a refractiva corneal. Se le implantaron  lentes f&#225;quicas ACR IOL-128 (Soleko, Italia) sin complicaciones. El equivalente  esf&#233;rico preoperatorio -11,5 y -6 dioptr&#237;as disminuy&#243; a -1,00 y  -0,5 respectivamente, y la agudeza visual sin cristales de cuenta dedos y 0,1  a 0,8 y 0,9 respectivamente. Con este caso se evidencia que las lentes f&#225;quicas  son una opci&#243;n con buenos resultados en la correcci&#243;n de la alta miop&#237;a.  <br/> <br/> </font>     <div align="left">        ]]></body>
<body><![CDATA[<p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Palabras      clave:</b> miop&#237;a alta; lente f&#225;quica ACR 128; lentes intraoculares.      </font></p>   <hr>   <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>ABSTRACT</b>    </font></div>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> The    high myopia, by definition, is that equal or bigger to -6 spherical dioptr&#237;as;    not in function of the bend high corneal, like it is the case of the queratocono,    neither for the sclerosis of the crystalline lens that happens in stages preseniles,    but in dependence of the axial longitude bigger than 25,5 or 26,0 mm. The optic    correction of these high defects is difficult, since it is frequent that the    patients feel uncomfortable with the glasses use, because they don't obtain    a good quality of vision and with the purpose of improving it, different surgical    procedures have been developed. Young patient 26 years old is presented with    high myopia that doesn't adapt to the contact eyeglasseses and she doesn't want    to continue with the espejuelos, she is not candidate to surgery refractive    corneal and she is implanted eyeglasseses f&#225;quica ACR IOL-128 (Soleko,    Italy) without complications. The equivalent spherical preoperatorio -11,5 and    -6 dioptr&#237;as diminish at -1,00 and - 0,5 respectively and the visual sharpness    without glasses of bill fingers and 0,1 at 0,8 and 0,9 respectively. With this    case it is evidenced that the lenses f&#225;quicas are an option with good results    in the correction of the high myopia. </font></p>     <div align="left">        <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>Key      words:</b> high myopia; ACR 128 phakic lens; intraocular lenses.</font></p>   <hr>       <p align="left">&nbsp;</p> </div>     <p align="left">&nbsp;</p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="3">INTRODUCCI&#211;N</font></b>    </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> La    miop&#237;a es el estado de la refracci&#243;n ocular causado por una o ambas    de las siguientes condiciones: el sistema de lentes compuesto por la c&#243;rnea    y el cristalino posee demasiada potencia; la longitud antero-posterior del ojo    es excesivamente grande; la imagen se proyecta por delante de la retina. La    miop&#237;a siempre supone una disminuci&#243;n en la agudeza visual lejana,    incluso en miop&#237;as ligeras. Es con frecuencia origen de disconfort, tras    el trabajo de cerca, por la desproporci&#243;n entre los esfuerzos de acomodaci&#243;n    y de convergencia.<sup>1</sup> </font></p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2">Existen    m&#250;ltiples clasificaciones de la miop&#237;a. Desde el punto de vista cl&#237;nico,    se clasifica en miop&#237;a simple (comienza en la adolescencia y se estabiliza    al final de la segunda d&#233;cada de la vida) y miop&#237;a patol&#243;gica    (miop&#237;a elevada, progresiva, hereditaria y aparece en la infancia antes    de los 10 a&#241;os), la cual puede progresar despu&#233;s de los 25-30 a&#241;os    y se acompa&#241;a de p&#233;rdida de la agudeza y cambios degenerativos v&#237;treo    y coriorretinianos. Esta &#250;ltima es la primera causa de ceguera en Asia,    donde ocurre en aproximadamente el 12-27 %.<sup>2</sup> </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> La    distribuci&#243;n geogr&#225;fica de la miop&#237;a en el mundo var&#237;a significativamente<sup>3-5</sup>    con cifras que oscilan desde el 6,1 % para Marruecos (&#193;frica) hasta el    96,5 % para Corea (Asia).<sup>6,7</sup> El contraste &#233;tnico y los h&#225;bitos    de vida en poblaciones asi&#225;ticas y africanas son los potenciales factores    asociados, aunque tal afirmaci&#243;n permanece sin dilucidar completamente.<sup>8</sup>    En el este de Asia la prevalencia de miop&#237;a alcanza el 80 %,<sup>9</sup>    mientras que en Europa es inferior, con un 47,2 % para el grupo entre 25 y 29    a&#241;os para el a&#241;o 2015. <sup>10</sup> En Am&#233;rica, en poblaciones    latinas como Brasil, la prevalencia en adultos era del 29,7 % para el a&#241;o    2009.<sup>11</sup> En Estados Unidos se evidencia un incremento desmesurado    de miopes, con una prevalencia que asciende del 25 al 41,6 % entre las edades    de 12 a 54 a&#241;os para el a&#241;o 2011.<sup>6,11</sup> En el reporte de    los pa&#237;ses que conforman la Red Epidemiol&#243;gica Iberoamericana para    la Salud Visual y Ocular, para el per&#237;odo 2009-2010, la menor prevalencia    se report&#243; en Argentina (1,2 %) y la mayor en Ecuador con un 25,2 %. En    Colombia, el diagn&#243;stico de miop&#237;a en los a&#241;os 2009 y 2010 fue    del 21 y 22 % respectivamente, con mayor prevalencia en el grupo de 5 a 14 a&#241;os,    seguido del de 15 a 44 a&#241;os.<sup>12</sup> En Cuba, seg&#250;n <i>Lantigua</i>,<sup>13</sup>    en un estudio realizado en el Instituto Cubano de Oftalmolog&#237;a &quot;Ram&#243;n    Pando Ferrer&quot;, los miopes representan un 19,79 %. </font></p>     ]]></body>
<body><![CDATA[<p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Tradicionalmente    factores de orden hereditario jugaban un papel exclusivo en la aparici&#243;n    de la miop&#237;a, con 10 veces mayor riesgo cuando en el primer grado de consanguinidad    prevalec&#237;a la miop&#237;a,<sup>14</sup> adem&#225;s de una alta probabilidad    de ser miopes cuando los dos padres presentaban la condici&#243;n, con una probabilidad    entre el 33 y el 60 %.<sup>1 </sup>Algunos estudios plantean que el efecto gen&#233;tico    se magnifica cuando se acompa&#241;a de factores ex&#243;genos como el estilo    de vida, que explican hasta el 4,4 % de la variaci&#243;n en la refracci&#243;n.<sup>15    </sup>En China la prevalencia en ni&#241;os de 15 a&#241;os es considerablemente    mayor que la de los padres (78,4 <i>vs.</i> 19,8 %).<sup>16</sup> Este incremento    puede ser explicado por la relaci&#243;n con otros factores como la limitada    exposici&#243;n al aire libre.<sup>17</sup> Desde el a&#241;o 2007 varios estudios    concuerdan en que las actividades al aire libre pueden detener la aparici&#243;n    de la miop&#237;a.<sup>18 </sup>Sin embargo, el mecanismo causal de este beneficio    a&#250;n no est&#225; claro: se cree que la vitamina D puede actuar como un    biomarcador de exposici&#243;n. <sup>19 </sup>Altos niveles de iluminaci&#243;n    pueden llevar a la emetropizaci&#243;n. En una cohorte de base poblacional (n=    1,344) en edades entre 19 y 22 a&#241;os, se present&#243; una relaci&#243;n    inversa entre el desarrollo de la miop&#237;a y la exposici&#243;n al sol, medida    de forma objetiva a trav&#233;s de autofluorescencia conjuntival como biomarcador    de exposici&#243;n solar.<sup>20</sup> </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> La    miop&#237;a constituye adem&#225;s un problema econ&#243;mico desde la prestaci&#243;n    de servicios de salud visual y el suministro de dispositivos &#243;pticos hasta    las intervenciones quir&#250;rgicas. Tambi&eacute;n genera p&#233;rdida de productividad,    independencia y reducci&#243;n en la calidad de vida de los que la padecen.<sup>21</sup>    </font></p>     <p align="left">&nbsp; </p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="3">CASO    CL&#205;NICO</font></b> </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Paciente    femenina de 26 a&#241;os de edad, con antecedentes de salud y miop&#237;a desde    peque&#241;a, corregida con cristales, pues no se adapt&#243; a los lentes de    contacto. Acude a la consulta para valorar la cirug&#237;a refractiva. </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> EXAMEN    OFTALMOL&#211;GICO </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> <i>Agudeza    visual sin correcci&#243;n (AVSC):</i> cuentadedos a un metro y medio en ojo    derecho (OD) y 0,1 en ojo izquierdo (OI).<i> </i></font><i><font face="Verdana, Arial, Helvetica, sans-serif" size="2">    <br>       <br>   Tensi&#243;n intraocular (TO):</font></i><font face="Verdana, Arial, Helvetica, sans-serif" size="2">    tensi&#243;n medida por aplanaci&#243;n con aire ajustada seg&#250;n paquimetr&#237;a):<i>    </i>14,0 mmHg OD y 13,0 mmHg OI.     <br>       ]]></body>
<body><![CDATA[<br>   <i>Biomicroscopia del segmento anterior:</i> sin alteraciones en ambos ojos    (AO). </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><i>    <br>       <br>   Oftalmoscopia indirecta: </i>papila de aspecto normal, no alteraciones en la    m&#225;cula ni en la retina perif&#233;rica en ambos ojos. </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> <b>Ex&#225;menes    preoperatorios</b></font></p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><i>Queratometr&#237;as    (K):</i> OD 45,00 X 65&#176;/43,00 X 155&#176; dioptr&#237;as; OI 44,75 X 120&#176;/42,75    X 30&#176; (<a href="#f1">Fig. 1</a>). <i>    <br>       <br>   Refracci&#243;n din&#225;mica: </i>OD -10,50 -2,00 X 165&#186; (1,0); OI -5,00    -2,00 X 35&#186; (1,0). <i>    <br>       <br>   Biometr&#237;a con el IOL M&#225;ster: </i>distancia blanco-blanco (WTW, siglas    en ingl&#233;s) (mm): OD 12,5; OI 12,4. <i>    <br>       ]]></body>
<body><![CDATA[<br>   Profundidad de la c&#225;mara anterior (ACD, siglas en ingl&#233;s) (mm): </i>OD    3,53; OI 3,64. <i>     <br>       <br>   Longitud axial (AL, siglas en ingl&#233;s) (mm):</i>OD 27,38; OI 25,34. <i>    <br>       <br>   Di&#225;metro pupilar (mes&#243;pico): </i>6,00 mm en AO. <i>Microscopia endotelial:</i>    densidad celular (CD, siglas en ingl&#233;s) OD 2 771 cel/mm<sup>2</sup>; OI    2 764 cel/mm<sup>2</sup>. <i>    <br>       <br>   Topograf&#237;a corneal con Magellan</i>: presenta un astigmatismo regular,    con ligero predomino inferior, a favor de la regla en OD y oblicuo en OI.<i>    </i></font><i><font face="Verdana, Arial, Helvetica, sans-serif" size="2">    <br>       <br>   Paquimetr&#237;a ultras&#243;nica:</font></i><font face="Verdana, Arial, Helvetica, sans-serif" size="2">    OD 514 &#181;m y OI 509 &#181;m. <i>    <br>       ]]></body>
<body><![CDATA[<br>   Impresi&#243;n diagn&#243;stica:</i> miop&#237;a elevada en ambos ojos, astigmatismo    mi&#243;pico compuesto y anisometrop&#237;a. </font></p>     <blockquote>        <p align="center"><img src="/img/revistas/oft/v31n2/f01_610.jpg" width="343" height="267"><a name="f1"></a></p> </blockquote>     <div align="left">       <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Se decidi&#243;      -bajo consentimiento informado, cumpliendo con lo establecido en el Sistema      Nacional de Salud y previsto en la Ley No. 41 de Salud P&#250;blica, en correspondencia      con la Declaraci&#243;n de Helsinki-<sup>22</sup> realizar implante de lente      f&#225;quica en AO, ya que presentaba un defecto alto con c&#243;rneas delgadas,      para realizar un tratamiento con l&#225;seres de exc&#237;meros. La lente      implantada fue ACR IOL-128 (Soleko, Italia) de PMMA-UV (polimetilmetacrilato      con protecci&#243;n a la luz ultravioleta) de soporte angular, con poderes      disponibles de -6,5 a -24, 0D. Con ayuda de una hoja de c&#225;lculo Excel,      mediante la f&#243;rmula o tabla de <i>Van der Heijde</i><sup>23 </sup>a partir      de la queratometr&#237;a, la refracci&#243;n y la profundidad de la c&#225;mara      anterior del ojo, se calcul&#243; el poder de ambas lentes (OD: -11,93 D y      OI: -6,71 D) y se implantaron (OD: -11 dioptr&#237;as (D) y OI: 6,5 D). </font></p>   <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><font color="#000000">Se    realiz&#243; iridotom&#237;a l&#225;ser dos semanas antes del procedimiento    quir&#250;rgico en hora 10 en el ojo derecho y hora 2 en el izquierdo. En el    preoperatorio inmediato se le indic&#243; manitol al 20 % endovenoso a durar    una hora para evitar el aumento de la presi&#243;n intraocular y se instil&#243;    colirio de pilocarpina al 2 %, 30 minutos antes de la cirug&#237;a, con el objetivo    de garantizar una adecuada miosis para facilitar las maniobras intraoculares    y la protecci&#243;n del cristalino. Se emple&#243; anestesia t&#243;pica e    intracameral. Como la lente utilizada es r&#237;gida con un di&#225;metro total    de 12,8 mm y una zona &#243;ptica de 5,50 mm, se prefiri&#243; hacer su colocaci&#243;n    por un t&#250;nel escleral-corneal de 5,50 mm para disminuir el astigmatismo    inducido, en hora 12 a 2 mm del limbo. Se realiz&#243; paracentesis en horas    3 y 9, se instil&#243; la anestesia intracameral, y se coloc&#243; viscoel&#225;stico    que facilita la introducci&#243;n del lente y protege el endotelio y el cristalino.    A trav&#233;s del t&#250;nel se penetr&#243; en c&#225;mara anterior y se introdujo    el lente, el cual qued&#243; con el h&#225;ptica con dos puntos de apoyo en    hora 6 y el h&#225;ptica de un solo punto de apoyo en hora 12, y se acomod&#243;    con rotador. Se extrajo el viscoel&#225;stico con irrigaci&#243;n de la c&#225;mara    anterior con soluci&#243;n salina balanceada. Se comprob&#243; el car&#225;cter    autosellante del t&#250;nel, se recubri&#243; con la conjuntiva y finalmente    se coloc&#243; una inyecci&#243;n subconjuntival de antinflamatorio esteroideo    (betametazona) y antibi&#243;tico (gentamicina). La cirug&#237;a se realiz&#243;    primero en su ojo dominante (OI) y no hubo complicaciones transoperatorias en    AO. </font> Se mantuvo con la administraci&#243;n de antibi&#243;tico t&#243;pico    y antinflamatorio esteroideo; se le dio seguimiento posoperatorio a las 24 horas,    a la semana y al mes sin reportarse complicaci&#243;n alguna (<a href="#f2">Fig.    2</a>). </font></div>     <blockquote>        <p align="center"><img src="/img/revistas/oft/v31n2/f02_610.jpg" width="574" height="273"><a name="f2"></a></p> </blockquote>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> <b>Resultados    posoperatorios</b></font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> <i>AVSC:</i>    0,8 OD y 0,9 OI. <i>TO</i> <i>(por aplanaci&#243;n con aire ajustada seg&#250;n    paquimetr&#237;a):</i> OD 15,0 mmHg y OI 14,0 mmHg. <i>Refracci&#243;n din&#225;mica:</i>    OD -0,50 -1,00 X 155&#186; (1,0) y OI -1,00 X 40&#186; (1,0).    <br>       ]]></body>
<body><![CDATA[<br>   <i>Microscopia endotelial:</i> OD 2 687cel/mm<sup>2</sup> CD y OI 2 683cel/mm<sup>2</sup>.    Actualmente se mantiene en seguimiento. </font></p>     <p align="left">&nbsp; </p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b><font size="3">DISCUSI&#211;N</font></b>    </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> La    alta miop&#237;a, por definici&#243;n, es aquella igual o mayor a -6 dioptr&#237;as    esf&#233;ricas; no en funci&#243;n de la curvatura corneal elevada, como es    el caso del queratocono, ni por la esclerosis del cristalino que ocurre en etapas    preseniles, sino en dependencia de la longitud axial mayor de 25,5 o 26 mm.<sup>1-5</sup>    </font></p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><i>Holden</i>    y otros, en un metan&#225;lisis sobre prevalencia y definici&#243;n de miop&#237;a    y alta miop&#237;a, en 145 estudios publicados entre los a&#241;os 1995 y 2015,    obtienen como definici&#243;n de miop&#237;a elevada de -6,00 D o m&#225;s en    el 30,5 % de los trabajos, de m&#225;s de -6,00 D en otro 30,5 %; de -5,00 D    o m&#225;s en el 35,6 %; de -8,00 o m&#225;s en el 1,7 % y de -3,00 o m&#225;s    en el 1,7 % restante. De ah&#237; que estandarizan -5,00D o m&#225;s como definici&#243;n    de alta miop&#237;a.<sup>8</sup> </font></p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2">La    correcci&#243;n &#243;ptica de estos defectos refractivos altos es dif&#237;cil,    ya que es frecuente que los pacientes se sientan inc&#243;modos con el uso de    gafas, pues no obtienen una buena calidad de visi&#243;n. Refieren molestias    por la presencia de halos o <i>glare</i>; las im&#225;genes se minimizan en    la miop&#237;a, si existe astigmatismo asociado se magnificar&#225; o minimizar&#225;    en diferente magnitud en los diferentes meridianos y el campo visual se encuentra    limitado en la periferia. Por otra parte, si existe un astigmatismo o una anisometrop&#237;a    importante, la adaptaci&#243;n a la correcci&#243;n con gafas puede ser dif&#237;cil    y si el astigmatismo es irregular no puede ser corregido con gafas, lo cual    limitar&#225; la agudeza visual que puede alcanzar el paciente.<sup>1-5 </sup>En    estos pacientes, las lentes de contacto proporcionan una mejor agudeza visual,    especialmente las lentes de contacto r&#237;gidas, ya que corrigen el astigmatismo    irregular. Adem&#225;s, al no producir una distorsi&#243;n del tama&#241;o de    las im&#225;genes, proporcionan una mejor calidad de visi&#243;n. Sin embargo,    en ocasiones se requieren dise&#241;os especiales para ser adaptadas sobre una    superficie corneal astigm&#225;tica, especialmente si presenta un componente    irregular.<sup>1-5</sup> El uso de lentes de contacto causa hipoxia corneal,    especialmente cuando son lentes gruesos para corregir errores refractivos altos    combinados con el uso por tiempo prolongado. La hipoxia incrementa el riesgo    de complicaciones como queratitis y neovascularizaci&#243;n corneal; tambi&#233;n    acelera la p&#233;rdida de c&#233;lulas endoteliales.<sup>24</sup> </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Con    el fin de mejorar la calidad de la visi&#243;n de los pacientes y cumplir con    sus exigencias, se desarrollan distintos procedimientos quir&#250;rgicos para    modificar la c&#243;rnea como son: la cirug&#237;a incisional, el implante de    anillos o lentes intracorneales y la fotoablaci&#243;n. Sin embargo, existen    l&#237;mites para su aplicaci&#243;n; de ah&#237; que se desarrollen t&#233;cnicas    intraoculares como son: la extracci&#243;n del cristalino transparente y el    implante de una lente intraocular (LIO), pero la p&#233;rdida de la acomodaci&#243;n    inherente a esta cirug&#237;a y el mayor riesgo de desprendimiento de retina    en miopes j&#243;venes da paso a otra opci&#243;n: el implante de una lente    intraocular en un ojo f&#225;quico, entre la c&#243;rnea y el cristalino, llamadas    lentes f&#225;quicas (PIOL, siglas en ingl&#233;s). En ocasiones es necesaria    la combinaci&#243;n de m&#225;s de un procedimiento.<sup>24</sup> </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> El    presente caso es un ejemplo de lo expuesto anteriormente. Un paciente joven    de 26 a&#241;os con un astigmatismo mi&#243;pico compuesto en ambos ojos, con    anisometrop&#237;a, que no se adapta a los lentes de contacto y desea quitarse    los espejuelos con los cuales su calidad visual no es buena y no es candidata    a la cirug&#237;a refractiva corneal por lo que se decide el implante de lente    f&#225;quica. </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> Aunque    en la literatura internacional no se encontraron reportes sobre la lente ACR    128, m&#250;ltiples pacientes a quienes se les han implantado lentes f&#225;quicos    de diferentes modelos han sido objeto de estudios en el mundo, los cuales mejoran    su funci&#243;n visual.<sup>24-27</sup> </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> En    el caso presentado se obtuvo equivalente esf&#233;rico (EE) posoperatorio de    -1,00 en el OD y -0,50 en el OI, lo cual coincide con <i>Knorz</i> (2011)<sup>26    </sup>y <i>Kohnen</i> (2009),<sup>27</sup> quienes tras el implante de la lente    AcrySof Cachet, de fijaci&#243;n angular similar a la implantada a la paciente,    publican EE posoperatorio medio entre &#177; 1,00 D en el 91,3 y 95,7 % respectivamente    y entre &#177; 0,50 D en el 78,9 % y 72,7 %. De igual manera, m&#225;s del 90    % de los ojos presentan EE &#177; 1,00 D y m&#225;s del 70 % EE &#177; 0,50    D en el ensayo cl&#237;nico realizado por la FDA, con implante de las lentes    de c&#225;mara anterior de fijaci&#243;n iridiana Artisan-Verisyse, Artiflex-    Veriflex.<sup>24</sup> </font></p>     ]]></body>
<body><![CDATA[<p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> No    encontramos publicaciones en Cuba sobre resultados visuales relacionadas con    la colocaci&#243;n de lentes f&#225;quicas de soporte angular; sin embargo,    en el a&#241;o 2007 se implantaron por primera vez los lentes Artisan/Artiflexcon    con resultados favorables.<sup>28 </sup><i>Ruiz</i> observa EE posoperatorio    entre &#177; 1,00 D en el 80 y el 90 % de los casos para Artiflex<sup>29 </sup>y    Artisan<sup>30 </sup>respectivamente. </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> No    se presentaron complicaciones en esta paciente, y la p&#233;rdida de c&#233;lulas    endoteliales fue en el OD del 3,0 % y en el OI del 2,9 %. Esto est&#225; relacionado    con la distancia de la lente a la c&#243;rnea &gt; 1,5 mm y al cristalino &gt;    0,3 mm en ambos ojos (<a href="#f3">Fig. 3</a>).</font></p>     <blockquote>        <p align="center"><img src="/img/revistas/oft/v31n2/f03_610.jpg" width="550" height="242"><a name="f3"></a></p> </blockquote>     <p><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><i>Knorz</i>,<sup>26</sup>    en un estudio de 3 a&#241;os de seguimiento de 360 ojos con implante de la lente    f&#225;quica AcrySof Cachet, publica diferentes complicaciones posoperatorias.    Ejemplos: los brillos y halos nocturnos son referidos entre el 18,8 y 20 % de    los casos inmediatamente despu&#233;s del procedimiento, y disminuye el 50 %    a los 3 a&#241;os; la pupila oval, seg&#250;n el tiempo de seguimiento, se presenta    entre el 5,9 y 27, 5 % casos, asociada a lentes grandes y la p&#233;rdida de    c&#233;lulas endoteliales entre el 4,6 y 8,4 % asociado a lentes peque&#241;as.    </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> En    el ensayo cl&#237;nico realizado por la FDA en 662 ojos con implante de las    lentes de fijaci&#243;n iridiana Artisan-Verisyse, Artiflex- Veriflex, en 3    a&#241;os de seguimiento reportan brillos y halos nocturnos entre el 13,5 y    18,2 % despu&#233;s de la cirug&#237;a, que disminuyen con el tiempo (12,9 %    y 9,8 %) y son m&#225;s graves en pupilas grandes. La p&#233;rdida de c&#233;lulas    endoteliales es del 4,8 % en 3 a&#241;os. Adem&#225;s, informa una tasa de desprendimiento    de retina de 0,3 x a&#241;o.<sup>24</sup> </font></p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> En    Cuba, con el implante de lentes de fijaci&#243;n iridiana Artisan <sup>30 </sup>y    Artiflex,<sup>29 </sup>se reporta visi&#243;n de halos en el 2,5 y 20 % de los    casos respectivamente; diferencia que puede estar dada por el tama&#241;o de    la muestra y el tiempo de seguimiento (Artisan: 120 ojos en 36 meses y Artiflex:    20 ojos en 24 meses). En cuanto a la p&#233;rdida de c&#233;lulas endoteliales    tras el implante de estas lentes en un a&#241;o de seguimiento, <i>Ruiz</i><sup>31</sup>    publica 2,5 % y <i>L&#243;pez</i><sup>32 </sup>4,6 %. </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">En    el presente caso se obtuvieron excelentes resultados con el implante de la lente    f&#225;quica ACR-128 para la correcci&#243;n de la alta miop&#237;a. </font></p>     <p align="left">&nbsp; </p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"><strong>Conflicto    de intereses</strong> </font></p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2">Los    autores declaran que no existe conflicto de intereses en el presente art&#237;culo.    </font></p>     ]]></body>
<body><![CDATA[<p align="left">&nbsp; </p>     <!-- ref --><p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><b>    <font size="3">REFERENCIAS BIBLIOGR&#193;FICAS </font><br/>   <br/>   </b> </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">1. Wong    TY, Ferreira A, Hughes R, Hughes R, Carter G, Mitchell P4. Epidemiology and    disease burden of pathologic myopia and myopic choroidal neovascularization:    an evidence-based systematic review. Am J Ophthalmol. 2014;157:9-25. <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">2. Pan CW,    Dirani M, Cheng CY, Wong TY, Saw SM. The age-specific prevalence of myopia in    Asia: a meta-analysis. Optom Vis Sci. 2015;92(3):258-66.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">3. Morgan    IG, Rose K. Yunnan minority eye study suggests that ethnic differences in myopia    are due to different environmental exposures. Invest Opthalmol Vis Sci. 2015;56:4430.    <!-- ref -->    <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">4. United    Nations Department of Economic and Social Affairs. World Urbanization Prospects:    The 2014 Revision; 2015 [citado 20 de enero de 2017]. Disponible en: <a href="http://esa.un.org/unpd/wup/2015" target="_blank">    http://esa.un.org/unpd/wup/2015 </a> <br/>   </font><!-- ref --><p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 5.    Hashemi H, Rezvan F, Beiranvand A, Papi OA, Hoseini YH, Ostadimoghaddam H, et    al. Prevalence of refractive errors among high school students in western Iran.    J Ophthalmic Vis Res. 2014;9(2):232-9.    <!-- ref --> <br/>   <br/>   6. Soler M. Prevalencia de errores refractivos en ni&#241;os africanos [Tesis];    2011 [citado 20 de enero de 2017]. Disponible en: <a href="http://0-hera.ugr.es.adrastea.ugr.es/tesis" target="_blank">    http://0-hera.ugr.es.adrastea.ugr.es/tesis ugr/19806735.pdf</a> <br/>   <br/>   7.    <!-- ref --> Dolgin E. The myopia boom. Nature. 2015;519(7543):276-8.    <!-- ref --> <br/>   <br/>   8. Holden BA, Fricke TR, Wilson DA, Jong M, Naidoo KS. Global prevalence of    myopia and high myopia and temporal trends from 2000 through 2050. Ophthalmology.    2016:123:1036-42.    <!-- ref --> <br/>   <br/>   9. Chassine T, Villain M, Hamel CPDV. How can we prevent myopia progression?    Eur J Ophthalmol. 2015;25(4):280-5.    <!-- ref --> <br/>   <br/>   10. Williams KM, Verhoeven VJM, Cumberland P, Bertelsen G, Wolfram C, Buitendijk    GH, et al. Prevalence of refractive error in Europe: The European Eye Epidemiology    (E3) Consortium. Eur J Epidemiol. 2015;30(4):305-15.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">11.<i> </i>    Rey-Rodr&#237;guez DV, &#193;lvarez-Peregrina C, Moreno-Montoya J. Prevalencia    y factores asociados a miop&#237;a en j&#243;venes. Rev Mex Oftalmol. 2016 [citado    20 de enero de 2017]. Disponible en: <a href="https://www.sciencedirect.com/science/article/pii/S018745191630066X" target="_blank">https://www.sciencedirect.com/science/article/pii/S018745191630066X</a></font><!-- ref --><p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 12.    Brusi L, Arg&#252;ello L, Alberdi A, Bergamini J, Toledo F, Teresa M, et al.    Informe de la salud visual y ocular de los pa&#237;ses que conforman la Red    Epidemiol&#243;gica Iberoamericana para la Salud Visual y Ocular (REISVO), 2009    y 2010. Rev Cienc Tecnol Salud Vis Ocul. 2015;13:11-43.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">13. Lantigua    I, Gonz&#225;lez Y, Machado E, Torrico M, Padilla C. Resultados del LASIK mi&#243;pico    en el Instituto Cubano de Oftalmolog&#237;a &#8220;Ram&#243;n Pando Ferrer&#8221;.    Rev Cubana Oftalmol. 2012;25(1):12-20.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">14. Sherwin    JC, Mackey DA. Update on the epidemiology and genetics of myopic refractive    error. Expert Rev Ophthalmol. 2014:1-42.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">15. Read    SA, Collins MJ, Vincent SJ. Light exposure and physical activity in myopic and    emmetropic children. Optom Vis Sci. 2014;91(3):330-41.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">16. Zhou    Z, Ma X, Yi H, Pang X, Shi Y, Chen Q. Factors underlying different myopia prevalence    between middle- and low-income provinces in China. Ophthalmology. 2015;122(5):1060-2.    <!-- ref -->    <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">17. Wu LJ,    You QS, Duan JL, Luo YX, Liu LJ, Li X. Prevalence and associated factors of    myopia in high-school students in Beijing. PloS One. 2015;10(3):e0120764.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">18. Zadnik    K. Who says there&#8217;s nothing new under the Sun? Optom Vis Sci. 2015; 92:392-3.    <!-- ref -->    <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">19. Choi    J, Han K, Park Y-M, La YT. Low serum 25-hydroxyvitamin is associated with myopia    in Korean adolescents. Investig Ophthalmology Vis Sci. 2014;55(4):2041-7.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">20. McKnight    CM, Sherwin JC, Yazar S, Forward H, Tan AX, Hewitt AW, et al. Myopia in young    adults is inversely related to an objective marker of ocular sun exposure: The    Western Australian Raine Cohort Study. Am J Ophthalmol. Elsevier Inc. 2014;158(5):1079-85.    <!-- ref -->    <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">21. Holden    B, Sankaridurg P, Smith E, Aller T, Jong M, He M. Myopia an underrated global    challenge to vision: Where the current data takes us on myopia control. Eye    (Lond). 2014;28(2):142-6.     <br/>   </font></p>     <!-- ref --><p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 22.    Di Ruggiero M. Declaraci&#243;n de Helsinki, principios y valores bio&#233;ticos    en juego en la investigaci&#243;n m&#233;dica con seres humanos. Rev Colomb    Bio&#233;t. 2011;6(1):125-44.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">23. Van der    Heijde GL, Fechner PU, Worst JG: Optical consequences of implantation of a negative    intraocular lens in myopic patients. Klin Monatsbl Augenheilkd. 1988;193:99-102.    <!-- ref -->    <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">24. American    Academy of Ophthalmology. Refractive Surgery. EE.UU.: </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Basic    and Clinical Science Course; 2015.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">25. Ali&#243;    Jl, Plaza-Puche AB, Cavas F, Y&#233;bana Rubio P, Sala E. An angle-supported    foldable phakic intraocular lens for correction of myopia: A five-year follow-up.    Arch Soc Esp Oftalmol. 2017;92(1):4-11.     <br/>   </font></p>     <!-- ref --><p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2"> 26.    Knorz MC, Lane SS, Holland SP. Angle-supported phakic intraocular lens for correction    of moderate to high myopia: Three-year interim results in international multicenter    studies. J Cataract Refract Surg. 2011;37(3):469-80.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">27. Kohnen    T, Maxwell A, Holland S. Correction of moderate to high myopia with a foldable,    angle-supported phakic intraocular lens. Ophthalmology. 2016;123:1027-35.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">28. Ruiz    Y, Capote A. Efectividad de los LIOs f&#225;quicos Artisan/Artiflex en la correcci&#243;n    de la alta miop&#237;a. Trabajo de terminaci&#243;n de residencia para optar    por el t&#237;tulo de Especialista de I Grado en Oftalmolog&#237;a. Instituto    Cubano de Oftalmolog&#237;a &#8220;Ram&#243;n Pando Ferrer&#8221;, La Habana,    Cuba; 2007.    <!-- ref --> <br/>   <br/>   </font><font face="Verdana, Arial, Helvetica, sans-serif" size="2">29. Ruiz    Y. Experiencia con los lentes f&#225;quicos Artiflex como opci&#243;n correctiva    de la alta miop&#237;a. Rev Cubana Oftalmol. 2010 [citado 20 de enero de 2017];23(1).    Disponible en: <a 		href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762010000100007&amp;lng=es&amp;nrm=iso&amp;tlng=es" target="_blank" 	> http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762010000100007&amp;lng=es&amp;nrm=iso&amp;tlng=es    </a> <br/>   <br/>   </font><font face="Verdana,    <!-- ref --> Arial, Helvetica, sans-serif" size="2">30. Ruiz    Y. Efectividad de los lentes f&#225;quicos Artisan en la correcci&#243;n de    la alta miop&#237;a. Rev Cubana Oftalmol. 2010 [citado 20 de enero de 2017];23(1).    Disponible en: <a 		href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762010000200011&amp;lng=es&amp;nrm=iso&amp;tlng=es" target="_blank" 	> http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762010000200011&amp;lng=es&amp;nrm=iso&amp;tlng=es    </a> <br/>   <br/>   </font><font face="Verdana,    <!-- ref --> Arial, Helvetica, sans-serif" size="2">31. Ruiz    Y. Estudio del endotelio corneal en la correcci&#243;n de alta miop&#237;a con    lente intraocular f&#225;quica Artisan. Rev Cubana Oftalmol. 2009 [citado 20    de enero de 2017];22(1). Disponible en: <a 		href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762009000100002&amp;lng=es&amp;nrm=iso&amp;tlng=es" target="_blank" 	> http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762009000100002&amp;lng=es&amp;nrm=iso&amp;tlng=es    </a> <br/>   <br/>   </font><font face="Verdana,    <!-- ref --> Arial, Helvetica, sans-serif" size="2">32. L&#243;pez    SM. Variaci&#243;n del endotelio corneal en pacientes operados de alta miop&#237;a    con implante de lentes f&#225;quicas. Rev Cubana Oftalmol. 2013 [citado 20 de    enero de 2017];26(3). Disponible en: <a 		href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762013000300002&amp;lng=es&amp;nrm=iso&amp;tlng=es" target="_blank" 	> http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-21762013000300002&amp;lng=es&amp;nrm=iso&amp;tlng=es    </a></font><p>&nbsp;</p>     <p>&nbsp;</p>     <p align="left"><font face="Verdana, Arial, Helvetica, sans-serif" size="2">Recibido:    15 de enero de 2018.<br/>   Aprobado: 4 de abril de 2018.</font></p>     <p align="left">&nbsp;</p>     <p align="left">&nbsp;</p>     <p align="left"> <font face="Verdana, Arial, Helvetica, sans-serif" size="2"><i>Taimi    C&#225;rdenas D&#237;az: </i> Instituto Cubano de Oftalmolog&#237;a &#8220;Ram&#243;n    Pando Ferrer&#8221;. La Habana, Cuba. Correo electr&#243;nico: <a href="mailto:taimicar@infomed.sld.cu">taimicar@infomed.sld.cu</a>    </font></p>      ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[TY]]></given-names>
</name>
<name>
<surname><![CDATA[Ferreira]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Hughes]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Hughes]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Carter]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Mitchell]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Epidemiology and disease burden of pathologic myopia and myopic choroidal neovascularization: an evidence-based systematic review]]></article-title>
<source><![CDATA[Am J Ophthalmol]]></source>
<year>2014</year>
<volume>157</volume>
<page-range>9-25</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pan]]></surname>
<given-names><![CDATA[CW]]></given-names>
</name>
<name>
<surname><![CDATA[Dirani]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Cheng]]></surname>
<given-names><![CDATA[CY]]></given-names>
</name>
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[TY]]></given-names>
</name>
<name>
<surname><![CDATA[Saw]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The age-specific prevalence of myopia in Asia: a meta-analysis]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2015</year>
<volume>92</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>258-66</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Morgan]]></surname>
<given-names><![CDATA[IG]]></given-names>
</name>
<name>
<surname><![CDATA[Rose]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Yunnan minority eye study suggests that ethnic differences in myopia are due to different environmental exposures]]></article-title>
<source><![CDATA[Invest Opthalmol Vis Sci]]></source>
<year>2015</year>
<volume>56</volume>
<page-range>4430</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="">
<collab>United Nations Department of Economic and Social Affairs</collab>
<source><![CDATA[World Urbanization Prospects: The 2014 Revision]]></source>
<year>2015</year>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hashemi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Rezvan]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Beiranvand]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Papi]]></surname>
<given-names><![CDATA[OA]]></given-names>
</name>
<name>
<surname><![CDATA[Hoseini]]></surname>
<given-names><![CDATA[YH]]></given-names>
</name>
<name>
<surname><![CDATA[Ostadimoghaddam]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevalence of refractive errors among high school students in western Iran]]></article-title>
<source><![CDATA[J Ophthalmic Vis Res]]></source>
<year>2014</year>
<volume>9</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>232-9</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Soler]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Prevalencia de errores refractivos en niños africanos]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dolgin]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The myopia boom]]></article-title>
<source><![CDATA[Nature]]></source>
<year>2015</year>
<volume>519</volume>
<numero>7543</numero>
<issue>7543</issue>
<page-range>276-8</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holden]]></surname>
<given-names><![CDATA[BA]]></given-names>
</name>
<name>
<surname><![CDATA[Fricke]]></surname>
<given-names><![CDATA[TR]]></given-names>
</name>
<name>
<surname><![CDATA[Wilson]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
<name>
<surname><![CDATA[Jong]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Naidoo]]></surname>
<given-names><![CDATA[KS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Global prevalence of myopia and high myopia and temporal trends from 2000 through 2050]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2016</year>
<volume>123</volume>
<page-range>1036-42</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chassine]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Villain]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Hamel]]></surname>
<given-names><![CDATA[CPDV]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[How can we prevent myopia progression]]></article-title>
<source><![CDATA[Eur J Ophthalmol]]></source>
<year>2015</year>
<volume>25</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>280-5</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Verhoeven]]></surname>
<given-names><![CDATA[VJM]]></given-names>
</name>
<name>
<surname><![CDATA[Cumberland]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bertelsen]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Wolfram]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Buitendijk]]></surname>
<given-names><![CDATA[GH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevalence of refractive error in Europe: The European Eye Epidemiology (E3) Consortium]]></article-title>
<source><![CDATA[Eur J Epidemiol]]></source>
<year>2015</year>
<volume>30</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>305-15</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rey-Rodríguez]]></surname>
<given-names><![CDATA[DV]]></given-names>
</name>
<name>
<surname><![CDATA[Álvarez-Peregrina]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Moreno-Montoya]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Prevalencia y factores asociados a miopía en jóvenes]]></article-title>
<source><![CDATA[Rev Mex Oftalmol]]></source>
<year>2016</year>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brusi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Argüello]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Alberdi]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bergamini]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Toledo]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Teresa]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Informe de la salud visual y ocular de los países que conforman la Red Epidemiológica Iberoamericana para la Salud Visual y Ocular (REISVO), 2009 y 2010]]></article-title>
<source><![CDATA[Rev Cienc Tecnol Salud Vis Ocul]]></source>
<year>2015</year>
<volume>13</volume>
<page-range>11-43</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lantigua]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Machado]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Torrico]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Padilla]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Resultados del LASIK miópico en el Instituto Cubano de Oftalmología &quot;Ramón Pando Ferrer&quot;]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2012</year>
<volume>25</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>12-20</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sherwin]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Mackey]]></surname>
<given-names><![CDATA[DA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Update on the epidemiology and genetics of myopic refractive error]]></article-title>
<source><![CDATA[Expert Rev Ophthalmol]]></source>
<year>2014</year>
<page-range>1-42</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Read]]></surname>
<given-names><![CDATA[SA]]></given-names>
</name>
<name>
<surname><![CDATA[Collins]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Vincent]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Light exposure and physical activity in myopic and emmetropic children]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2014</year>
<volume>91</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>330-41</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Ma]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Yi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Pang]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Shi]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[Q]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Factors underlying different myopia prevalence between middle- and low-income provinces in China]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2015</year>
<volume>122</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1060-2</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[You]]></surname>
<given-names><![CDATA[QS]]></given-names>
</name>
<name>
<surname><![CDATA[Duan]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Luo]]></surname>
<given-names><![CDATA[YX]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[LJ]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prevalence and associated factors of myopia in high-school students in Beijing]]></article-title>
<source><![CDATA[PloS One]]></source>
<year>2015</year>
<volume>10</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>e0120764</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zadnik]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Who says there&apos;s nothing new under the Sun]]></article-title>
<source><![CDATA[Optom Vis Sci]]></source>
<year>2015</year>
<volume>92</volume>
<page-range>392-3</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Choi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Han]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Park]]></surname>
<given-names><![CDATA[Y-M]]></given-names>
</name>
<name>
<surname><![CDATA[La]]></surname>
<given-names><![CDATA[YT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Low serum 25-hydroxyvitamin is associated with myopia in Korean adolescents]]></article-title>
<source><![CDATA[Investig Ophthalmology Vis Sci]]></source>
<year>2014</year>
<volume>55</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>2041-7</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McKnight]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[Sherwin]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Yazar]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Forward]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tan]]></surname>
<given-names><![CDATA[AX]]></given-names>
</name>
<name>
<surname><![CDATA[Hewitt]]></surname>
<given-names><![CDATA[AW]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Myopia in young adults is inversely related to an objective marker of ocular sun exposure: The Western Australian Raine Cohort Study]]></article-title>
<source><![CDATA[Am J Ophthalmol. Elsevier Inc]]></source>
<year>2014</year>
<volume>158</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1079-85</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holden]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Sankaridurg]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Aller]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Jong]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[He]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Myopia an underrated global challenge to vision: Where the current data takes us on myopia control]]></article-title>
<source><![CDATA[Eye (Lond)]]></source>
<year>2014</year>
<volume>28</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>142-6</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Di Ruggiero]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Declaración de Helsinki, principios y valores bioéticos en juego en la investigación médica con seres humanos]]></article-title>
<source><![CDATA[Rev Colomb Bioét]]></source>
<year>2011</year>
<volume>6</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>125-44</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Van der Heijde]]></surname>
<given-names><![CDATA[GL]]></given-names>
</name>
<name>
<surname><![CDATA[Fechner]]></surname>
<given-names><![CDATA[PU]]></given-names>
</name>
<name>
<surname><![CDATA[Worst]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optical consequences of implantation of a negative intraocular lens in myopic patients]]></article-title>
<source><![CDATA[Klin Monatsbl Augenheilkd]]></source>
<year>1988</year>
<volume>193</volume>
<page-range>99-102</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="book">
<collab>American Academy of Ophthalmology</collab>
<source><![CDATA[Refractive Surgery]]></source>
<year>2015</year>
<publisher-name><![CDATA[Basic and Clinical Science Course]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Alió]]></surname>
<given-names><![CDATA[Jl]]></given-names>
</name>
<name>
<surname><![CDATA[Plaza-Puche]]></surname>
<given-names><![CDATA[AB]]></given-names>
</name>
<name>
<surname><![CDATA[Cavas]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Yébana Rubio]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Sala]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An angle-supported foldable phakic intraocular lens for correction of myopia: A five-year follow-up]]></article-title>
<source><![CDATA[Arch Soc Esp Oftalmol]]></source>
<year>2017</year>
<volume>92</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>4-11</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Knorz]]></surname>
<given-names><![CDATA[MC]]></given-names>
</name>
<name>
<surname><![CDATA[Lane]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
<name>
<surname><![CDATA[Holland]]></surname>
<given-names><![CDATA[SP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Angle-supported phakic intraocular lens for correction of moderate to high myopia: Three-year interim results in international multicenter studies]]></article-title>
<source><![CDATA[J Cataract Refract Surg]]></source>
<year>2011</year>
<volume>37</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>469-80</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kohnen]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Maxwell]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Holland]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correction of moderate to high myopia with a foldable, angle-supported phakic intraocular lens]]></article-title>
<source><![CDATA[Ophthalmology]]></source>
<year>2016</year>
<volume>123</volume>
<page-range>1027-35</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Capote]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<source><![CDATA[Efectividad de los LIOs fáquicos Artisan/Artiflex en la corrección de la alta miopía]]></source>
<year></year>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Experiencia con los lentes fáquicos Artiflex como opción correctiva de la alta miopía]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2010</year>
<volume>23</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Efectividad de los lentes fáquicos Artisan en la corrección de la alta miopía]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2010</year>
<volume>23</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ruiz]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estudio del endotelio corneal en la corrección de alta miopía con lente intraocular fáquica Artisan]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2009</year>
<volume>22</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Variación del endotelio corneal en pacientes operados de alta miopía con implante de lentes fáquicas]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2013</year>
<volume>26</volume>
<numero>3</numero>
<issue>3</issue>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
