<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1684-1824</journal-id>
<journal-title><![CDATA[Revista Médica Electrónica]]></journal-title>
<abbrev-journal-title><![CDATA[Rev.Med.Electrón.]]></abbrev-journal-title>
<issn>1684-1824</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Ciencias Médicas de Matanzas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1684-18242018000100014</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Máscaras laríngeas. Tres décadas después]]></article-title>
<article-title xml:lang="en"><![CDATA[Laryngeal masks. Three decades later]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[González del Pino Ruz]]></surname>
<given-names><![CDATA[Israel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Bofill Gil]]></surname>
<given-names><![CDATA[Pavel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Liriano González]]></surname>
<given-names><![CDATA[María Isabel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Suarez Servia]]></surname>
<given-names><![CDATA[Osiris]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Valenzuela López]]></surname>
<given-names><![CDATA[Ketty]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ramos Domínguez]]></surname>
<given-names><![CDATA[Yoania]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Hospital Provincial Docente Pediátrico Eliseo Noel Caamaño  ]]></institution>
<addr-line><![CDATA[ Matanzas]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>02</month>
<year>2018</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>02</month>
<year>2018</year>
</pub-date>
<volume>40</volume>
<numero>1</numero>
<fpage>129</fpage>
<lpage>143</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1684-18242018000100014&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1684-18242018000100014&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1684-18242018000100014&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN Las máscaras laríngeas son dispositivos supraglóticos que ofrecen una alternativa a la tradicional intubación endotraqueal con potenciales beneficios. El propósito de este trabajo fue mostrar el estado actual de las máscaras laríngeas en Anestesiología y Reanimación. Se realizó una búsqueda sobre el tema en documentos impresos y electrónicos, así como en las siguientes bases de datos: Registro Cochrane Central, Lilacs, PubMed/Medline, SCielo regional, Google. En estos momentos existe una amplia gama de mascarillas laríngeas cuyo diseños superan a las anteriores en cuanto a facilidad y tiempo de inserción, presión de sellado y menor riesgo de complicaciones; lo que ha permitido incrementar su uso en pacientes pediátricos, obesos, obstétricas, en cirugía laparoscópica, en el algoritmo de la vía aérea difícil, en la reanimación cardiopulmonar, fuera del quirófano y en el medio extrahospitalario.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT Laryngeal masks are supraglottal devices offering an alternative to the traditional endotracheal intubation with potential benefits. The purpose of this work was showing the current status of the laryngeal masks in Anesthesiology and Reanimation. A search on the theme was carried out in electronic and printed documents, and also in the following databases Central Cochrane Register, Lilacs, PubMed/Medline, SCielo regional and Google. At this moment there is a wide variety of laryngeal masks, the design of which excels the previous one in parameters like insertion easiness and time, sealing pressure and less risks of complication, allowing increasing their use in pediatric, obese and obstetric patients, in laparoscopic surgery, in the algorithm for the difficult airway, in cardiopulmonary reanimation, outside the operating room and in extra hospital settings.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[máscaras laríngeas]]></kwd>
<kwd lng="es"><![CDATA[dispositivos supraglóticos]]></kwd>
<kwd lng="es"><![CDATA[abordaje de la vía aérea]]></kwd>
<kwd lng="es"><![CDATA[vía aérea difícil]]></kwd>
<kwd lng="en"><![CDATA[laryngeal masks]]></kwd>
<kwd lng="en"><![CDATA[supraglottal devices]]></kwd>
<kwd lng="en"><![CDATA[airway approach]]></kwd>
<kwd lng="en"><![CDATA[difficult airway]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>ARTICULO DE REVISI&Oacute;N</strong></font></p>     <p align="left">&nbsp;</p>     <p align="left"><font size="4" face="Verdana, Arial, Helvetica, sans-serif"><strong>M&aacute;scaras  lar&iacute;ngeas. Tres d&eacute;cadas despu&eacute;s</strong></font></p>     <p align="left">&nbsp;</p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong><font size="3">Laryngeal masks. Three decades later</font></strong></font></p>     <p align="left">&nbsp;</p>     <p align="left">&nbsp;</p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Dr. Israel Gonz&aacute;lez del Pino Ruz, Dr. Pavel Bofill  Gil, Dra. Mar&iacute;a Isabel Liriano  Gonz&aacute;lez, Dra Osiris Suarez Servia, Dra. Ketty Valenzuela L&oacute;pez,   Dra. Yoania Ramos Dom&iacute;nguez&nbsp;&nbsp; </strong></font></p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Hospital Provincial  Docente Pedi&aacute;trico Eliseo Noel Caama&ntilde;o. Matanzas, Cuba. </font></p>     <p align="left">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify">&nbsp;</p> <hr align="JUSTIFY">     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>RESUMEN</strong></font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Las m&aacute;scaras lar&iacute;ngeas son dispositivos  supragl&oacute;ticos&nbsp; que ofrecen una  alternativa a la tradicional intubaci&oacute;n endotraqueal con potenciales beneficios.  El prop&oacute;sito de este trabajo fue mostrar&nbsp;  el estado&nbsp; actual de las m&aacute;scaras  lar&iacute;ngeas en&nbsp; Anestesiolog&iacute;a y  Reanimaci&oacute;n. Se realiz&oacute;&nbsp; una b&uacute;squeda  sobre el tema en documentos impresos y electr&oacute;nicos, as&iacute; como en las siguientes  bases de datos: Registro Cochrane&nbsp; Central, Lilacs, PubMed/Medline, SCielo  regional, Google. &nbsp;En estos momentos &nbsp;existe una amplia gama de mascarillas  lar&iacute;ngeas cuyo dise&ntilde;os superan a las anteriores en cuanto a facilidad y tiempo  de inserci&oacute;n, presi&oacute;n de sellado y menor riesgo de complicaciones; lo que ha  permitido&nbsp; incrementar su uso en &nbsp;pacientes pedi&aacute;tricos, obesos, obst&eacute;tricas, en  cirug&iacute;a laparosc&oacute;pica, en el algoritmo de la v&iacute;a a&eacute;rea dif&iacute;cil, en la reanimaci&oacute;n  cardiopulmonar, fuera del quir&oacute;fano y en el medio extrahospitalario.</font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>Palabras  claves: </strong>m&aacute;scaras lar&iacute;ngeas, dispositivos supragl&oacute;ticos,  abordaje de la v&iacute;a a&eacute;rea, v&iacute;a a&eacute;rea dif&iacute;cil.</font></p> <hr align="JUSTIFY">     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>ABSTRACT</strong></font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Laryngeal masks are supraglottal devices  offering an alternative to the traditional endotracheal intubation with  potential benefits. The purpose of this work was showing the current status of  the laryngeal masks in Anesthesiology and Reanimation. A search on the theme  was carried out in electronic and printed documents, and also in the following  databases Central Cochrane Register, Lilacs, PubMed/Medline, SCielo regional  and Google. At this moment there is a wide variety of laryngeal masks, the  design of which excels the previous one in parameters like insertion easiness  and time, sealing pressure and less risks of complication, allowing increasing  their use in pediatric, obese and obstetric patients, in laparoscopic surgery,  in the algorithm for the difficult airway, in cardiopulmonary reanimation,  outside the operating room and in extra hospital settings.    <br>       <br>     <strong>Key words</strong>: laryngeal masks, supraglottal devices, airway  approach, difficult airway.</font></p> <hr>     <p align="left">&nbsp;</p>     <p align="left">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify"><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>INTRODUCCI&Oacute;N</strong></font> </p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Tres d&eacute;cadas han pasado desde que  Archie Brain introdujo la m&aacute;scara  lar&iacute;ngea (ML) en el arsenal del anestesi&oacute;logo.<sup>1</sup> A partir de  entonces este dispositivo ha tenido una evoluci&oacute;n constante.<sup>2</sup>Las  modificaciones que se les ha&nbsp;  realizado ha permitido ampliar  sus indicaciones, extender sus usos a otros escenarios y reducir las  complicaciones relacionadas con su empleo.<sup>3</sup>    <br>       <br> Las m&aacute;scaras lar&iacute;ngeas ofrecen una alternativa a la  tradicional intubaci&oacute;n endotraqueal con potenciales beneficios sobre esta.<sup>4</sup>  Como no requiere de laringoscopia se previene la respuesta al estr&eacute;s generada  durante la manipulaci&oacute;n de la v&iacute;a respiratoria.<sup>5</sup> Se evitan los  traumatismos relacionados con la intubaci&oacute;n. El cuff inflado forma un sello  alrededor de la entrada de la laringe. Los &nbsp;requerimientos de agentes anest&eacute;sicos son&nbsp; menores. Pueden ser colocadas sin necesidad  de relajantes musculares.<sup>6</sup> Adem&aacute;s son mejor toleradas por los  pacientes y se asocian a menor incidencia de tos y de dolor de garganta.<sup>7</sup></font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los nuevos modelos introducidos en el mercado se caracterizan por su f&aacute;cil colocaci&oacute;n, ventilaci&oacute;n predecible, menos riesgo de aspiraci&oacute;n pulmonar y permiten la intubaci&oacute;n traqueal a trav&eacute;s de  ellas.<sup>8,9</sup> Teniendo en cuenta lo anterior se decidi&oacute; realizar una  revisi&oacute;n con el objetivo de mostrar el  estado actual de las m&aacute;scaras lar&iacute;ngeas  en Anestesiolog&iacute;a y Reanimaci&oacute;n. </font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>MATERIALES Y M&Eacute;TODOS</strong></font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se realiz&oacute;&nbsp;una b&uacute;squeda relacionada con el tema en documentos impresos y electr&oacute;nicos, as&iacute; como en las siguientes bases de datos: Registro Cochrane Central, Lilacs,&nbsp;PubMed/Medline, SCielo regional, Google. Se expusieron los resultados de investigaciones sobre las m&aacute;scaras lar&iacute;ngeas. Se mostr&oacute; la experiencia de los autores.</font></p>     <p align="justify">&nbsp;</p>     <p align="justify"><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>DISCUSI&Oacute;N</strong></font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La ML es un dispositivo de gran utilidad para el  anestesi&oacute;logo, utilizado preferentemente para procederes quir&uacute;rgicos de corta y  mediana duraci&oacute;n o en pacientes dif&iacute;ciles de intubar. Se ha usado con  magn&iacute;ficos resultados para la ventilaci&oacute;n en este tipo de eventualidad, donde  los m&eacute;todos convencionales fueron fallidos, <a href="#f1">figura</a></font>.</p>     <p align="center"><a name="f1"></a><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><img src="/img/revistas/rme/v40n1/f011418.jpg" width="364" height="321"></p>     
<p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Mart&iacute;nez Hurtado,<sup>10</sup> se&ntilde;ala que en  la actualidad existen por lo menos 20  tipos mascarillas lar&iacute;ngeas, las cuales  han sido clasificadas teniendo en cuenta diversos criterios como la  presencia o no de tubo de drenaje  g&aacute;strico,<sup>11</sup> si son rehusable  o desechables, la facilidad de intubaci&oacute;n a trav&eacute;s de ellos, etc.<sup><sup>12</sup></sup>    <br>       <br>   Seg&uacute;n la  presencia del tubo esof&aacute;gico se han clasificado en dos generaciones. La primera  generaci&oacute;n &nbsp;que consistente en un tubo  simple para el paso de aire fijado a una m&aacute;scara&nbsp; que descansa sobre la glotis; y la segunda  generaci&oacute;n incorpora un canal a trav&eacute;s del cual se puede introducir un tubo  g&aacute;strico.<sup>11</sup> A la primera pertenece la &nbsp;ML Cl&aacute;sica<em>,</em> y todas las m&aacute;scaras lar&iacute;ngeas&nbsp; Standard,<sup>13</sup> mientras que la  segunda incluye las m&aacute;scaras lar&iacute;ngeas&nbsp; ProSeal  y&nbsp; Supreme.<sup>14,15</sup>    <br>       <br>   La ML Cl&aacute;sica LMATM fue  introducida en Gran Breta&ntilde;a en 1983 por  Dr. Archie Brain y en 1991 fue aprobada en Estados Unidos por la Federaci&oacute;n de Drogas y  Alimentos. En su dise&ntilde;o cuenta con un aditamento en su extremo distal que a  modo de diafragma sella el extremo superior de la laringe. La misma se  introduce en boca siguiendo la curvatura de la superficie dorsal de la lengua,  y se avanza lentamente hasta atravesar las estructuras de la oro faringe y  sentir un resalto caracter&iacute;stico. Entonces, se insufla el manguito, se acopla a  la fuente de gases, se ventila y se ausculta para comprobar la eficacia del  procedimiento.<sup>1</sup> Este dispositivo&nbsp;  utilizado para el manejo de la v&iacute;a a&eacute;rea, ha tenido buena aceptaci&oacute;n  pues brinda un alto grado de &eacute;xito y es de f&aacute;cil colocaci&oacute;n.<sup>16</sup>    <br>       <br>   La ML flexiblees similar a la cl&aacute;sica pero  el canal de ventilaci&oacute;n est&aacute; reforzado con un cable&nbsp; para ofrecer flexibilidad<em>. </em>Esto hace que sea&nbsp;&uacute;til para procederes quir&uacute;rgicos de la cavidad  oral, en los cuales un dispositivo semirr&iacute;gido puede obstaculizar la cirug&iacute;a o  doblarse y causar obstrucci&oacute;n.<sup>8</sup> Tambi&eacute;n resulta  beneficiosa para cirug&iacute;a de la cara y el  cuello por el bajo riesgo de  desplazamiento de la v&iacute;a a&eacute;rea.<sup>17</sup>    <br>       ]]></body>
<body><![CDATA[<br>   Ge,<sup>18</sup> utiliz&oacute; la   ML flexible<em> en </em>40  pacientes programados para cirug&iacute;a oral y maxilofacial con anestesia general.  El dispositivo fue colocado del primer intento  en el 80 % (32/40) y del segundo en&nbsp;50 % (4/8). En uno de ellos fue necesario sustituirlo por un  tubo endotraqueal antes de comenzar la cirug&iacute;a debido a fugas. La incidencia de dolor de  garganta fue de 13.8 %. No se identificaron otras complicaciones. Hubo pocos  cambios hemodin&aacute;micos.    <br>       <br>   La ML Fastrach (LMA-Fastrach&trade; rehusable), tambi&eacute;n conocida como ML de intubaci&oacute;n es utilizada para abordar la  tr&aacute;quea de forma segura en situaciones dif&iacute;ciles. Fue lanzada en 1995&nbsp; en San Diego.<sup>8</sup> Consta de un  mango met&aacute;lico para su inserci&oacute;n y una &nbsp;leng&uuml;eta movible a trav&eacute;s de la cual se puede  introducir un tubo endotraqueal convencional, un broncoscopio o un dispositivo  creado con el fin de introducir un tubo endotraqueal. &nbsp;Es un instrumento&nbsp; que facilita la ventilaci&oacute;n continua durante  y entre intentos de intubaci&oacute;n, lo que disminuye la probabilidad de saturaci&oacute;n.<sup>1</sup> En los pacientes  con v&iacute;a a&eacute;rea normal tiene una tasa de ventilaci&oacute;n adecuada d.-el 99-100 %, y una  tasa de &eacute;xito de intubaci&oacute;n traqueal de 97-99,3 %.<sup>19</sup>     <br>       <br>   La ML Proseal TM<em>, </em>incorporada  en el a&ntilde;o 2000 en&nbsp; Estados Unidos,<sup>8</sup> es la &nbsp;primera de la segunda generaci&oacute;n  de dispositivos&nbsp; con un&nbsp; nuevo dise&ntilde;o de doble tubo que separa la v&iacute;a  respiratoria de la digestiva, lo que provee as&iacute; un canal seguro para la  eliminaci&oacute;n el exterior de fluidos regurgitados de forma inesperada o colocar a  trav&eacute;s del es&oacute;fago una sonda&nbsp;para  drenaje de contenido g&aacute;strico.<sup>14</sup>    <br>        <br>   Similar a la ProSeal, la ML Supremetiene un acceso al est&oacute;mago a trav&eacute;s del cual se puede colocar un  drenaje g&aacute;strico y resulta f&aacute;cil de insertar.<sup>14</sup> Difiere de  esta en que es desechable, su&nbsp; columna  curva es r&iacute;gida, la cazoleta tiene barras de retenci&oacute;n de la epiglotis y el  manguito tiene un perfil aumentado lo que proporciona&nbsp; una&nbsp;  protecci&oacute;n&nbsp; de sellado. Introducida en el 2007 su uso  se&nbsp; haya muy extendido.<sup>2</sup> Una explicaci&oacute;n al rendimiento superior de la Supreme&trade;  es que&nbsp; su dise&ntilde;o es menos voluminoso, lo  que hace &nbsp;posible que su inserci&oacute;n sea m&aacute;s predecible y que el tama&ntilde;o  de la lengua influya menos en comparaci&oacute;n con un dispositivo supragl&oacute;tico con  bal&oacute;n no inflable.<sup>20</sup>    <br>       <br>   Van Esch,<sup>21</sup> realiz&oacute; una revisi&oacute;n  sistem&aacute;tica sobre las complicaciones relacionadas con las m&aacute;scaras lar&iacute;ngeas y  la intubaci&oacute;n endotraqueal. En ella incluy&oacute; 19 estudios en los cuales se usaron  ML cl&aacute;sica, ML ProSeal<em>, </em>ML flexible y  ML Supreme. Esta &uacute;ltima estuvo relacionada con menor incidencia de  complicaciones.    <br>       ]]></body>
<body><![CDATA[<br>   La   ML Unique  es una versi&oacute;n para un solo uso de la ML Cl&aacute;sica<em>.</em><sup>17</sup> Est&aacute; hecha principalmente de policloruro de vinilo (PVC) transparente  (el tubo de v&iacute;a a&eacute;rea) y silicona (el manguito).<sup>22</sup>    <br>       <br>   En un estudio,<sup>23</sup> acerca de la ventilaci&oacute;n espont&aacute;nea con las&nbsp; m&aacute;scaras lar&iacute;ngeas Unique (LMAU) y Ambudurante la anestesia general en adultos, se observ&oacute; que esta &uacute;ltima produjo presiones de sellado  mayores lo cual result&oacute; estad&iacute;sticamente significativo (<em>Ambu </em>20 &plusmn; 6; <em>LMAU</em> 15 &plusmn; 7&thinsp;cmH2O; P = 0.001). Con respecto al &eacute;xito al abordar la via a&eacute;rea, el tiempo  de inserci&oacute;n, sangramiento y dolor&nbsp;  garganta postoperatorio no existieron diferencias.    <br>       <br>   La m&aacute;scara lar&iacute;ngea Ambu (ALM&trade;) es un dispositivo&nbsp; hecho de  cloruro de polivilino, moldeado en  una pieza, cuya curva reproduce la  anatom&iacute;a&nbsp; humana. Est&aacute; dise&ntilde;ada para  ofrecer la flexibilidad necesaria para adaptarse a la anatom&iacute;a individual.<sup>24</sup>    <br>       <br>   La familia de dispositivos Ambu Aura presenta una variedad de tipos como  la AuraOnce,  Aura 40, AuraStraight, AuraFlex y Aura i, las cuales fueron dise&ntilde;adas para un solo uso, excepto la Aura 40 que es rehusable.<sup>14</sup>    <br>       <br>   La ML reutilizable Aura 40 tiene una curva  especial que facilita su colocaci&oacute;n&nbsp; sin  esfuerzo y sin traumatizar la v&iacute;a a&eacute;rea  superior. Tambi&eacute;n asegura que la cabeza del paciente se mantenga en una posici&oacute;n neutral. La punta reforzada  ayuda a prevenir pliegues durante la  inserci&oacute;n que pueden provocar una colocaci&oacute;n incorrecta y posibles fugas de  aire. El posicionamiento es m&aacute;s r&aacute;pido y preciso siempre.<sup>24</sup>    <br>       ]]></body>
<body><![CDATA[<br>   En su estudio, Siddharam,<sup>25</sup> confirm&oacute;  que la ML <em>Ambu Aura  40</em> es superior a la <em>I-gel</em>&nbsp; y a la ML <em>Cl&aacute;sica</em> <em>TM</em> en cuanto a facilidad de inserci&oacute;n, visualizaci&oacute;n de la glotis y presi&oacute;n de sellado.    <br>       <br>   Los autores tambi&eacute;n hemos encontrado mayor  facilidad de inserci&oacute;n y &eacute;xito en la  ventilaci&oacute;n con la   Ambu Aura 40 en relaci&oacute;n con la ML <em>Cl&aacute;sica</em> TM tanto en ni&ntilde;os como en  adultos.    <br>       <br>   Ambu AuraOnce<em>, </em>es una ML desechable cuya forma permite una inserci&oacute;n correcta, f&aacute;cil  y r&aacute;pida. Tiene un tubo de la v&iacute;a a&eacute;rea en forma de D que proporciona un agarre firme y  ergon&oacute;mico durante la inserci&oacute;n. El posicionamiento es r&aacute;pido&nbsp; y preciso, con una baja presi&oacute;n interna.<sup>24</sup>    <br>       <br>   Susana,<sup>26</sup> en su publicaci&oacute;n &ldquo;<em>Comparaci&oacute;n entre la m&aacute;scara lar&iacute;ngea  Cl&aacute;sica y la Ambu   AuraOnce en pacientes sometidos a anestesia general electiva  con&nbsp; ventilaci&oacute;n a presi&oacute;n positiva&rdquo;,</em> demostr&oacute; que ambos dispositivos son comparables en t&eacute;rminos de facilidad de  inserci&oacute;n, pero la <em>AuraOnce</em> produjo mejor sellado durante la ventilaci&oacute;n con menos incidencia de dolor de  garganta en el postoperatorio.    <br>        <br>   En  una revisi&oacute;n sistem&aacute;tica sobre la eficacia y seguridad de la <em>Ambu&reg; </em>AuraOnce<em>&trade;</em> para anestesia general,<sup>27 </sup>se  compar&oacute; con la <em>ML Unique&trade;</em>, <em>ML Cl&aacute;sica&reg;</em> y Soft Seal<em>&reg;, </em>en ella&nbsp; fueron  incluidos 4, 5 y 3 estudios respectivamente. La <em>ML</em>&nbsp;AuraOnce  proporcion&oacute; mayor&nbsp; presi&oacute;n de sellado que  la ML Uniquey&nbsp;  equivalente a la de la   Cl&aacute;sica.&nbsp; La inserci&oacute;n  fue m&aacute;s r&aacute;pida con la AuraOnceque con laML   Unique y la <em>Soft Seal</em>, pero  similar a la <em>ML Cl&aacute;sica</em>. El &eacute;xito  en la colocaci&oacute;n de primer intento para la <em>AuraOnce</em> fue equivalente a la <em>ML Unique, MLCl&aacute;sica </em>y<em> Soft Seal</em>. En relaci&oacute;n a  las complicaciones hubo&nbsp; mayor incidencia  de manchas de sangre en el cuff de la <em>Soft Seal</em> y de dolor de garganta con la <em>ML Cl&aacute;sica</em>.  Concluy&oacute; que la <em>AuraOnce</em> es una  alternativa efectiva a las m&aacute;scaras lar&iacute;ngeas <em>cl&aacute;sica</em> y <em>Unique</em> en mayor  facilidad de inserci&oacute;n que los otros dispositivos estudiados.</font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Aqil,<sup>28</sup> analiz&oacute; la relaci&oacute;n espacial de la <em>ML</em> <em>Ambu&reg; AuraOnce</em> TM y la <em>i-gel&reg;</em> en pacientes pedi&aacute;tricos, basados en im&aacute;genes de resonancia  magn&eacute;tica en 3D. La <em>i-gel&reg;</em> produjo un grado&nbsp;  significativo de compresi&oacute;n de la lengua (P&lt;0.001) mientras la&nbsp; <em>Ambu&reg; AuraOnce</em> TM&nbsp;redujo significativamente el di&aacute;metro axial de  la glotis (P=0.033). Ambas redujeron significativamente el a&eacute;rea apertura  gl&oacute;tica (P&lt;0.001) y la distancia entre los aritenoides (P&lt;0.001 y P=0.007 respectivamente); se increment&oacute; la  distancia entre el hueso hioides y la  columna cervical (P&lt;0.001 y P=0.001 respectivamente) en comparaci&oacute;n con los  valores basales. La cazoleta de la  i-gel&reg; produce mayor dilataci&oacute;n del esf&iacute;nter esof&aacute;gico superior en  comparaci&oacute;n con la <em>Ambu&reg; AuraOnce</em> TM&nbsp; .&nbsp;&nbsp; </font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Singh,<sup>29</sup> uso la <em>ML</em> <em>Ambu&reg; AuraOnce</em> TM en el rescate de la v&iacute;a a&eacute;rea en una paciente con  limitada apertura de la boca por quemaduras post quimioterapia ingresada en  cuidados intensivos hasta que se logr&oacute;  realizar la traqueotom&iacute;a. Se&ntilde;ala que aunque se requieren m&aacute;s estudios para  recomendarla con seguridad deber&iacute;a formar parte del equipamiento para el manejo  de la v&iacute;a a&eacute;rea en los departamentos de emergencia y cuidados intensivos.    <br>       <br>   La ML recta desechable <em>Ambu AuraStraight,</em> proporciona&nbsp; una alternativa a la popular <em>AuraOnce</em> para su uso tanto en anestesia  como medicina de emergencia. A diferencia de otras mascarillas lar&iacute;ngeas, <em>Ambu</em> <em>AuraStraight </em>cuenta con un dise&ntilde;o recto moldeado  tambi&eacute;n en una sola pieza. Adem&aacute;s, tiene un manguito extrasuave. Por lo tanto,  el sellado se ajusta a la forma de la v&iacute;a a&eacute;rea con la cantidad m&iacute;nima de presi&oacute;n.  Cuenta con una superficie que facilita  la inserci&oacute;n y extracci&oacute;n.<sup>24</sup>     <br>   &nbsp;    <br>   <em>Ambu  AuraFlex, </em>es  una ML desechable, la cu&aacute;l ha sido  especialmente dise&ntilde;ada para intervenciones en otorrinolaringolog&iacute;a,  oftalmolog&iacute;a, odontolog&iacute;a, y otras cirug&iacute;as. Tiene un tubo a&eacute;reo largo, &nbsp;reforzado y flexible que permite una  colocaci&oacute;n lejos del campo quir&uacute;rgico&nbsp;  sin la p&eacute;rdida del sellado. El tubo a&eacute;reo no se dobla&nbsp; sobre s&iacute; mismo, lo que elimina el riesgo de  obstrucci&oacute;n del tubo de la v&iacute;a a&eacute;rea. Adem&aacute;s, consta de un tubo de inflado  integrado que hace m&aacute;s f&aacute;cil el trabajo del cirujano y reduce el riesgo que se  rompa durante la intervenci&oacute;n. Est&aacute; disponible en una gama completa desde la  talla 2 hasta la 6.<sup>24</sup>    <br>       <br>   Con el prop&oacute;sito de  comparar la ML <em>Ambu AuraFlex</em> con la <em>ML</em> <em>flexible, </em>Sanuki,<sup>30</sup> escogi&oacute;  a 30 estudiantes de odontolog&iacute;a quienes nunca hab&iacute;an usado ML y bajo  supervisi&oacute;n introdujeron cada dispositivo en un maniqu&iacute;.&nbsp;    <br>        <br>   El tiempo de inserci&oacute;n fue m&aacute;s corto con la &nbsp;<em>Ambu AuraFlex</em> (26.6 &plusmn; 7.1 segundos  vs 30.3 &plusmn; 6.8 segundos; P = .045). El &eacute;xito de inserci&oacute;n fue de 93.3 % para&nbsp; <em>Ambu  AuraFlex</em> y de 76.7 % para la <em>ML flexible, </em>diferencias que no fueronestad&iacute;sticamente significativas (P = .145). La inserci&oacute;n&nbsp; de la <em>Ambu   AuraFlex</em> fue considerada menos dif&iacute;cil que la <em>ML flexible</em> con una media de 41 mm&nbsp; y 60 mm, respectivamente, de la escala visual  an&aacute;loga usada para ello (0-100mm). De la investigaci&oacute;n concluy&oacute; que la <em>ML   Ambu AuraFlex</em> parece ser m&aacute;s &uacute;til para personas sin experiencia.     <br>       ]]></body>
<body><![CDATA[<br>   La <em>Ambu Aura-i&trade;</em>, fabricada de PVC, fue introducida en la cl&iacute;nica  en el a&ntilde;o 2010. Ella&nbsp; comprende un tubo  cuya&nbsp; curva forma un&nbsp; &aacute;ngulo de 90&deg; imita  la curvatura normal de la orofaringe con la punta redondeada y suave y  manguito de 0.40mm.<sup>30,31</sup> Este dispositivo est&aacute; dise&ntilde;ado para facilitar la  intubaci&oacute;n endotraqueal&nbsp; guiada por  fibroscopio &oacute;ptico.<sup>32</sup>     <br>       <br>   Yahaya y colaboradores,<sup>2</sup>  compararon las m&aacute;scaras lar&iacute;ngeas&nbsp; <em>Ambu&reg;  Aura-i</em> y <em>LMA Supreme&trade; </em>en 100  pacientes ASA I y II, sin relajaci&oacute;n muscular, programadas para cirug&iacute;a ginecol&oacute;gica menor.  Como resultado en 43 pacientes (86 %) <em>Ambu  Aura-i</em> y 44 (88%) <em>ML &nbsp;Supreme </em>fueron insertada con &eacute;xito del primer intento  (<em>p</em> = 0.59) con similar facilidad (<em>p</em> = 0.79), y tiempos  comparables para el primer capnograma, 18.2 &plusmn; 6.0 versus 17.3 &plusmn; 6.4 segundos <em>p</em> = 0.9. La&nbsp; <em>Aura-i</em> necesit&oacute; significativamente menos volumen de aire para inflar el cuff a 60cmH2O en el man&oacute;metro, 17.7&nbsp; &plusmn;  3.5 versus 23.1 &plusmn; 4.4 ml, <em>p</em> &lt; 0.001. El 90 % de los pacientes  tuvieron una buena colocaci&oacute;n de la <em>Aura-i</em> cuando se comprob&oacute; con el fibroscopio al  visualizarse las cuerdas vocales y la&nbsp;  epiglotis. En 5 pacientes (10%), las cuerdas vocales no fueron visibles  pero la ventilaci&oacute;n no se vio afectada.</font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En  un estudio realizado en ni&ntilde;os se concluy&oacute;  que las m&aacute;scaras lar&iacute;ngeas <em>Ambu</em> <em>Aura-i</em> y <em>Air-Q </em>son efectivas para la intubaci&oacute;n  endotraqueal guiada por fibroscopio, con ventajas que incluyen la f&aacute;cil  manipulaci&oacute;n, &eacute;xito en la realizaci&oacute;n, y  escasas complicaciones, especialmente con la&nbsp; <em>Ambu Aura-I.</em><sup>33</sup> Pav&oacute;n,<sup>32</sup> redujo el riesgo hipoxemia e hipercapnia al  aplicar presi&oacute;n positiva&nbsp; durante la  intubaci&oacute;n con fibroscopio &oacute;ptico a trav&eacute;s&nbsp;  de esta &uacute;ltima<em>.</em></font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La <em>ML Ambu&reg;  AuraGainTM</em> (Ambu A/S, Ballerup, Dinamarca), es un nuevo dispositivo extragl&oacute;tico  de segunda generaci&oacute;n, de un solo uso, con una curvatura anat&oacute;mica que permita  una r&aacute;pida inserci&oacute;n. Es una modificaci&oacute;n de la <em>Ambu</em> <em>Aura-iTM</em>.  Dispone de un canal g&aacute;strico y puede utilizarse como conducto para la  intubaci&oacute;n traqueal guiada con fibrobroncoscopio.<sup>19</sup>&nbsp;Est&aacute;  fabricada tambi&eacute;n con PVC y libre de  l&aacute;tex. La misma tiene&nbsp; un manguito que  garantiza altas presiones de sellado (hasta 40 cmH2O), un bloque mordedor que  evita las&nbsp; oclusiones ante mordidas del  paciente, y marcas de profundidad para ayudar a un  posicionamiento correcto. Presenta adem&aacute;s&nbsp;  marcas de navegaci&oacute;n para uso de fibroscopio &oacute;ptico. Se puede usar para  resonancia magn&eacute;tica.<sup>10</sup>     <br>       <br>   Jagannathan,<sup>34</sup> estudi&oacute; el comportamiento  de las m&aacute;scaras lar&iacute;ngeas <em>Ambu&reg;</em> <em>AuraGain&trade;</em> y la <em>ML</em> <em>Supreme</em>para el mantenimiento de la v&iacute;a a&eacute;rea  durante la ventilaci&oacute;n mec&aacute;nica en ni&ntilde;os, y no hall&oacute; diferencias en cuanto a  facilidad, tiempo y &eacute;xito al insertarlas, colocaci&oacute;n de un tubo g&aacute;strico y  complicaciones. Mientras queShariffuddin,<sup>15</sup> tambi&eacute;n compar&oacute; &nbsp;ambas m&aacute;scaras lar&iacute;ngeas pero en pacientes anestesiados que ventilaban  espont&aacute;neamente, sin encontrar diferencias en la presi&oacute;n de sellado y el porciento de &eacute;xito al colocar las m&aacute;scaras  del primer intento; en este caso observ&oacute; que la <em>AuraGain</em>fue  m&aacute;s dif&iacute;cilde colocar y necesit&oacute; m&aacute;stiempo para ello(33.4&plusmn;10.9 versus 27.3&plusmn; 1.4 segundos),no obstante facilit&oacute; la inserci&oacute;n de un tubo g&aacute;strico (100% versus  90.9%) y tuvo una disminuci&oacute;n significativa del score de molestias en la  garganta en relaci&oacute;n a la <em>Supreme</em> (10% versus 38%). </font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Las m&aacute;scaras lar&iacute;ngeas <em>Air-Q</em> y <em>Baska Mask</em> son dispositivos que no  presentan manguito para hinchar la cazoleta y mantienen la presi&oacute;n por s&iacute;  mismas, ya que son autopresurizables.     <br>       <br>   La <em>ML</em> <em>Air-Q</em> (ILA, Cookgas L.L.C., St. Louis, MO), dise&ntilde;ada por el Dr. Cook, fue introducida  en USA en 2004, como un dispositivo supragl&oacute;tico, que permit&iacute;a la intubaci&oacute;n a  trav&eacute;s de ella. En 2011 apareci&oacute; la   ML <em>Air-Q SP</em> (autopresurizante), desechable y que  se puede usar como conducto para la intubaci&oacute;n, igual que el resto de las  mascarillas Air-Q.    ]]></body>
<body><![CDATA[<br>       <br>   A diferencia de la mascarilla Air-Q original no  presenta ning&uacute;n aparato de inflado, por ello no se puede hinchar, pero la  presi&oacute;n en el manguito es autorregulable, porque incorpora una amplia apertura  en la uni&oacute;n del tubo de v&iacute;a a&eacute;rea y el manguito, lo que permite la comunicaci&oacute;n  entre ellos, para autopresurizar el manguito durante la ventilaci&oacute;n con presi&oacute;n  positiva, es decir, a medida que se eleva la presi&oacute;n en el tubo de la v&iacute;a a&eacute;rea  durante la ventilaci&oacute;n con presi&oacute;n positiva o la aplicaci&oacute;n de PEEP, el  manguito se presuriza de forma simult&aacute;nea y en igual cantidad, lo cual mejora  el sellado del manguito.    <br>       <br>   Presenta un sistema de auto inflado mediante el  cual el manguito se infla con la ventilaci&oacute;n con presi&oacute;n positiva y se desinfla  durante la espiraci&oacute;n hasta el nivel de la PEEP. As&iacute; se evita el paso extra de inflado del  manguito tras la inserci&oacute;n y se elimina el problema de sobre inflado del  manguito, adem&aacute;s se consigue un sellado eficiente con baja presi&oacute;n. Este  aumento de la presi&oacute;n del manguito s&oacute;lo ocurre durante la fase de presurizaci&oacute;n  de la ventilaci&oacute;n (introducci&oacute;n del aire al paciente), con lo que se consigue  un sellado m&aacute;s seguro, eficiente y de baja presi&oacute;n.    <br>       <br> La presi&oacute;n  en el manguito var&iacute;a sucesivamente entre la presi&oacute;n pico de la v&iacute;a a&eacute;rea (15-30  cmH2O). Esta bajada c&iacute;clica de la presi&oacute;n en el manguito  (presurarizaci&oacute;n puls&aacute;til del manguito), reduce complicaciones como traumatismo  en los nervios y mucosas (por la presi&oacute;n elevada constante con otras  mascarillas). Se precisa una peque&ntilde;a apertura bucal para su introducci&oacute;n desde  25mm para el n&ordm; 4,5 hasta 8 mm para el n&ordm; 0,5. La mascarilla Air-Q en general y  este modelo en particular, se ablanda progresivamente ya que al asentarse en la  hipofaringe del paciente se equilibra con la temperatura del mismo.<sup>10</sup>    <br>     <br> En la publicaci&oacute;n &ldquo;<em>Air Q.M&aacute;scara lar&iacute;ngea de intubaci&oacute;n:un estudio de dispositivos de  segunda generaci&oacute;n&rdquo;,</em>2016, de Attarde,<sup>35</sup> se puede constatar  que en el 88.3% de los pacientes el  dispositivo fue insertado del primer intento y en el 11.7% restante en el  segundo. En la totalidad de los pacientes la ventilaci&oacute;n fue adecuada. La intubaci&oacute;n  se logr&oacute; con &eacute;xito en el 76.7% de los  casos mientras que el 23.3% de los pacientes fue intubado mediante  laringoscopia directa despu&eacute;s de dos intentos fallidos con&nbsp; la&nbsp; <em>Air Q</em>.    <br>      <br> Jin,<sup>36</sup> se&ntilde;ala que  varios estudios han demostrado la eficacia de la <em>Air-Q</em> en pacientes pedi&aacute;tricos en comparaci&oacute;n  con otros dispositivos como ML <em>Cl&aacute;sica,  i-gel, Aura-I y&nbsp;&nbsp; CobraPLA.    ]]></body>
<body><![CDATA[<br> </em>&nbsp;    <br> La <em>Baska   Mask&reg;</em> fue dise&ntilde;ada por los anestesi&oacute;logos  australianos&nbsp; Kanag y Meena Baska. Este dispositivo trae mezclado  rasgos de la <em>ML ProSeal</em>, de la <em>ML   Supreme&reg;, </em>&nbsp;de la <em>I-gel</em> y de la <em>SLIPA.</em><sup>37</sup> Se trata de un dispositivo que proporciona acceso independiente  al tracto respiratorio y digestivo (canal de succi&oacute;n directo o posibilidad de  paso de una sonda nasog&aacute;strica). Al ser fabricado&nbsp; de silicona no es &nbsp;traum&aacute;tico y se adapta completamente a la  anatom&iacute;a del paciente, tiene una leng&uuml;eta para facilitar su inserci&oacute;n. Posee un  bloque antimordedura a lo largo de todo el tubo de la v&iacute;a a&eacute;rea. Presenta un  manguito no hinchable, que se diferencia de los previos en que se contin&uacute;a con  el canal central de ventilaci&oacute;n, y est&aacute; dise&ntilde;ado de manera que el manguito se  auto hincha a medida que aumenta la presi&oacute;n con la ventilaci&oacute;n mec&aacute;nica. Este  m&eacute;todo de auto hinchado por ventilaci&oacute;n permite altas presiones de sellado.     <br>     <br> El diafragma suave del manguito se infla de manera  fisiol&oacute;gica durante la fase inspiratoria de la ventilaci&oacute;n, y se retrae a los  niveles atmosf&eacute;ricos durante la espiraci&oacute;n pasiva. Se evitan as&iacute; posibles da&ntilde;os  a consecuencia de un sobre inflado del manguito y permite altas presiones de  sellado.<sup>10</sup>     <br>     <br> L&oacute;pez,<sup>38</sup> valor&oacute; el comportamiento cl&iacute;nico de la Baska Mask<em>&reg;,</em> en&nbsp; 80 pacientes sin criterios de v&iacute;a a&eacute;rea  dif&iacute;cil. La tasa de &eacute;xito de inserci&oacute;n al primer intento fue del 88%, y la  global, del 100%, aunque en el 44% de los casos fue necesario rotar o curvar el  dispositivo. La ventilaci&oacute;n fue eficaz en el 96% y se requirieron &nbsp;maniobras de ajuste en el 39%.     <br>     <br> La presi&oacute;n de  sellado fue de 33&nbsp;&plusmn;&nbsp;7&nbsp;cmH2O. La visi&oacute;n total o parcial de las cuerdas vocales  se obtuvo en el 90%, en el 5% se observ&oacute; obstrucci&oacute;n parcial por distorsi&oacute;n del  borde libre del bal&oacute;n, y en el 5% restante no se identificaron estructuras  gl&oacute;ticas. La inserci&oacute;n de la sonda g&aacute;strica fue f&aacute;cil en todos los casos. Las  complicaciones fueron leves y transitorias. Con el estudio demostr&oacute; que la Baska Mask consigui&oacute;  una presi&oacute;n de sellado elevada, una ventilaci&oacute;n adecuada y un acceso g&aacute;strico  r&aacute;pidos; sin embargo, requiri&oacute; con frecuencia aplicar maniobras de ajuste para  la inserci&oacute;n y para obtener una ventilaci&oacute;n adecuada.    <br>     <br> La evoluci&oacute;n de las m&aacute;scaras lar&iacute;ngeas ha permitido  que el uso de las mismas se haya incrementado  y se utilice en situaciones  especiales, por ejemplo:    ]]></body>
<body><![CDATA[<br>      <br> En  pediatr&iacute;a las m&aacute;scaras lar&iacute;ngeas han sido &uacute;tiles para el abordaje rutinario de la v&iacute;a a&eacute;rea durante la anestesia, en pacientes con intubaci&oacute;n  dif&iacute;cil, para la reanimaci&oacute;n cardipulmonar (RCP) y en situaciones de  emergencia.<sup>7,39</sup>    <br>     <br> Las m&aacute;scaras lar&iacute;ngeas Cl&aacute;sica, Unique, Proseal,  Supreme, Aura Straight, Aura Once/ Aura 40, Aura i y Air Q han&nbsp; sido fabricadas de todos los tama&ntilde;os incluso  para neonatos, lactantes y ni&ntilde;os peque&ntilde;os. La ML <em>flexible</em> se encuentra disponible para ni&ntilde;os a partir de 10 kg. De la ML <em>Fastrach</em> existen solo tres tama&ntilde;os para adultos: 3 (30-50 kg), 4 (50-70kg) y 5 (&gt; 70  kg).<sup>8</sup>     <br>     <br> Fuera del quir&oacute;fano las m&aacute;scaras lar&iacute;ngeas tienen  amplio uso en el paciente pedi&aacute;trico, tal es el caso de&nbsp; salas de radiolog&iacute;a, radioterapia,<sup>8,11</sup> endoscopia digestiva<sup>14</sup> y broncoscopia.<sup>39</sup>    <br> &nbsp;     <br> Aunque en la paciente embarazada la intubaci&oacute;n  endotraqueal es &nbsp;la &laquo;regla de oro&raquo;, por  el alto riesgo de broncoaspiracion, en el algoritmo de manejo de v&iacute;a a&eacute;rea debe  darse prioridad a&nbsp; la oxigenaci&oacute;n y  ventilaci&oacute;n de la parturienta y considerar el uso precoz de dispositivos  supragl&oacute;ticos: ML Fastrach, ML&nbsp; ProSeal TM,  ML Supreme TM<em>.</em><sup>38</sup>    <br>     <br> El empleo de  la ML en cirug&iacute;a  laparosc&oacute;pica ha sido motivo de controversias debido al riesgo de regurgitaci&oacute;n  y aspiraci&oacute;n pulmonar, as&iacute; como &nbsp;de &nbsp;ventilaci&oacute;n sub&oacute;ptima o inadecuada durante el  proceder. En una revisi&oacute;n realizada Bele&ntilde;a y colaboradores,<sup>40</sup>  sobre el tema, encontraron evidencia para recomendar&nbsp; las m&aacute;scaras lar&iacute;ngeas con acceso g&aacute;strico  en pacientes&nbsp; seleccionados. Basados en sus hallazgos  sugieren el uso de ML para colecistectom&iacute;a laparosc&oacute;pica en pacientes ASA  I-III, cirug&iacute;a electiva, no obesos, presi&oacute;n del neumoperitoneo menor de 13  mmhg, siempre que se usen m&aacute;scaras lar&iacute;ngeas con canal de acceso g&aacute;strico y se realice&nbsp; profilaxis de la aspiraci&oacute;n de contenido  g&aacute;strico.    ]]></body>
<body><![CDATA[<br>     <br>  Aunque el riesgo de aspiraci&oacute;n pulmonar no puede ser totalmente  rechazado, se la reportado una baja incidencia de esta en la literatura.  La eficacia y seguridad de las m&aacute;scaras lar&iacute;ngeas <em>Supreme </em>y <em>ProSeal </em>para colecistectom&iacute;a  laparosc&oacute;pica fue investigada por Anand y colaboradores,<sup>41</sup> quienes comprobaron que la ML ProSeal tuvo mayor presi&oacute;n  de sellado, sin embargo la Supreme  fue m&aacute;s f&aacute;cil de insertar en menos tiempo y  con mayor &eacute;xito al colocarla del  primer intento. Concluyeron que los dos dispositivos son efectivos para la  ventilaci&oacute;n en este tipo de cirug&iacute;a.     <br>     <br> Las m&aacute;scaras lar&iacute;ngeas Air-Q, Aura-i y Fastrach  permiten insertar f&aacute;cilmente un tubo endotraqueal a trav&eacute;s de ellas sin riesgo  de extubacion accidental.&nbsp; Ramachandran,<sup>12</sup>  en su publicaci&oacute;n Dispositivos supragl&oacute;ticos (2016) cita a Halwagi quien us&oacute; la&nbsp; <em>ML</em> Fastrachen un estudio multic&eacute;ntrico que incluy&oacute;  a 254 pacientes con v&iacute;a a&eacute;rea dif&iacute;cil conocida y logr&oacute; &eacute;xito en la intubaci&oacute;n  en el 96.5 % de los casos. La   ML Air-Q&nbsp; tambi&eacute;n puede  ser usada con &eacute;xito&nbsp; para&nbsp; la intubaci&oacute;n guiada por fibroscopio &oacute;ptico.     <br>     <br> En el paciente obeso en la actualidad se recomienda  la ventilaci&oacute;n con dispositivos supragl&oacute;ticos con respecto a la m&aacute;scara facial en el orden del manejo f&aacute;cil de la v&iacute;a a&eacute;rea y administraci&oacute;n  de PEEP, lo que previene as&iacute; la hipoxia.<sup>32</sup>    <br>      <br> Las m&aacute;scaras lar&iacute;ngeas, tanto en adultos como en ni&ntilde;os,&nbsp;ofrecen &nbsp;una gu&iacute;a directa para el pasaje del  broncoscopio y brinda una serie de ventajas para la fibrobroncoscopia comparado  con el tubo endotraqueal: es menos traum&aacute;tica para los tejidos de la v&iacute;a a&eacute;rea  superior, permite la visualizaci&oacute;n de la glotis, el espacio subgl&oacute;tico y la  tr&aacute;quea superior, puede ser usada  durante la respiraci&oacute;n espont&aacute;nea y permite evaluar la din&aacute;mica de la v&iacute;a a&eacute;rea  para el diagn&oacute;stico de traqueomalacia o broncomalacia y la funci&oacute;n de cuerdas  vocales.    <br>     <br> El estudio realizado por Consuegra Carvajal,<sup>42</sup> demostr&oacute; que la ML Fastrachpermite&nbsp;el control de la ventilaci&oacute;n de manera  continua durante los intentos de introducci&oacute;n del fibroscopio, garantiza vol&uacute;menes  adecuados de ventilaci&oacute;n con niveles de presi&oacute;n en la v&iacute;a a&eacute;rea apropiados, y  brinda mayor seguridad al procedimiento.    ]]></body>
<body><![CDATA[<br>     <br> La   ML Unique  es un dispositivo vers&aacute;til para ser usado en una variedad de escenarios  prehospitalarios.<sup>22</sup></font></p>     <p align="left">&nbsp;</p>     <p align="justify"><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>CONCLUSIONES</strong></font></p>     <p align="justify"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se concluye que en la  actualidad existe una amplia gama de mascarillas lar&iacute;ngeas cuyo dise&ntilde;os superan a las primeras generaciones en  cuanto a facilidad y tiempo de inserci&oacute;n, presi&oacute;n de sellado y menor riesgo de  complicaciones, lo que ha permitido incrementar  su uso en pacientes pedi&aacute;tricos, obesos,  obst&eacute;tricas, en cirug&iacute;a laparosc&oacute;pica, en el algoritmo de la v&iacute;a a&eacute;rea dif&iacute;cil,  en la RCP, fuera  del quir&oacute;fano y el en&nbsp; medio  extrahospitalario. </font></p>     <p align="justify">&nbsp;</p>     <p align="left"><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><strong>REFERENCIAS BIBLIOGR&Aacute;FICAS</strong></font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">1- Cordero  Escobar I. Anestesiolog&iacute;a. Criterios y tendencias actuales. La Habana. Editorial  Ciencias M&eacute;dicas; 2013.     </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">2- Yahaya Z, Teoh WH,&nbsp;  Dintan NA,&nbsp; Agrawal R. The AMBU&reg;  Aura-i&trade; Laryngeal Mask and LMA Supreme&trade;: A Randomized Trial of Clinical  Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients  by Novices. Anesthesiol Res Pract. 2016. Citado en  Pub Med: PMID: 27847515.    </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">3- Bele&ntilde;a  JM, Gasco C, Polo CE, et al. Laryngeal mask, laryngeal tube, and frova introducer  in simulated difficult airway. J  Emerg Med [Internet]. 2015 [citado 8 Ago. 2017];48(2):254-9. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/25453860" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/25453860</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">4- Nicholson  A, Cook TM, Smith AF, Lewis SR, Reed SS. Supraglottic airway devices versus  tracheal intubation for airway management during general anaesthesia in obese  patients. Cochrane Database Syst Rev [Internet]. 2013 Sep [citado 8 Ago. 2017];9(9).  Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/24014230" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/24014230</a> </font><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">5- Siddharam J, Anuradha H,&nbsp; Ramesh K.&nbsp;  I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic  Cholecystectomy &ndash; A Clinical Comparative Study. Indian Journal of Clinical  Anaesthesia [Internet]. 2015 [citado 8 Ago. 2017];2(4):235-239.  Disponible en: <a href="http://www.indianjournals.com/ijor.aspx?target=ijor:ijca1&volume=2&issue=4&article=009" target="_blank">http://www.indianjournals.com/ijor.aspx?target=ijor:ijca1&amp;volume=2&amp;issue=4&amp;article=009</a> </font></p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">6- Dwivedi MB, Nagrale M, Dwivedi S, Singh H. What happens to the  hemodynamic responses for laryngeal mask airway insertion when we supplement  propofol with butorphanol or fentanyl for induction of&nbsp; anesthesia: A comparative assessment and  critical review. Int J Crit Illn Inj Sci. [Internet]. 2016 Jan-Mar [citado 8 Ago.  2017];6(1):40&ndash;44. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4795361/" target="_blank">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4795361/</a></font></p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">7- Kari&scaron;ik M. Simple, timely,  safely? Laryngeal mask and pediatric airway. Acta Clin  Croat [Internet]. 2016 Mar [citado 8 Ago. 2017];55(Suppl. 1):55-61. Disponible  en: <a href="http://pdfs.semanticscholar.org/f6f2/c896484ea3f7382003a055423d7d741465b4.pdf" target="_blank">http://pdfs.semanticscholar.org/f6f2/c896484ea3f7382003a055423d7d741465b4.pdf</a> </font></p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">8- Hern&aacute;ndez MR, Klock A,&nbsp; Ovassapian A. Evolution of the Extraglottic  Airway: A Review of Its History, Applications, and Practical Tips for Success. Anesth  Analg [Internet]. 2012 [citado 8 Ago.  2017];114:349&ndash;68. Disponible en: <a href="http://journals.lww.com/anesthesia-analgesia/Abstract/2012/02000/Evolution_of_the_Extraglottic_Airway___A_Review_of.16.aspx" target="_blank">http://journals.lww.com/anesthesia-analgesia/Abstract/2012/02000/Evolution_of_the_Extraglottic_Airway___A_Review_of.16.aspx</a> </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">9- Rodr&iacute;guez Ram&iacute;rez C, Berm&uacute;dez Berm&uacute;dez SM, Cordero  Escobar I, Abela Lazo A. M&aacute;scara lar&iacute;ngea I Gel vs ProSeal en cirug&iacute;a  oncol&oacute;gica de mama. Revista Cubana de Anestesiolog&iacute;a y Reanimaci&oacute;n [Internet].  2014 [citado 8 Ago. 2017];13(1):15-30. Disponible en: <a href="http://scielo.sld.cu/scielo.php?pid=S1726-67182014000100004&script=sci_arttext&tlng=pt" target="_blank">http://scielo.sld.cu/scielo.php?pid=S1726-67182014000100004&amp;script=sci_arttext&amp;tlng=pt</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">10- Mart&iacute;nez  Hurtado E, S&aacute;nchez Merchante&nbsp; M. Nuevas  mascarillas lar&iacute;ngeas, la tercera generaci&oacute;n. Anestesiar.org [Internet]. 2015 [citado 8 Ago. 2017]. Disponible en: <a href="http://anestesiar.org/2014/nuevas-mascarillas-laringeas-la-3a-generacion/" target="_blank">http://anestesiar.org/2014/nuevas-mascarillas-laringeas-la-3a-generacion/</a> </font><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">11- Jagannathan N, Ramsey M, White M, Sohn L. An update on  newer pediatric supraglottic airways with recommendations for clinical use. Pediatric  Anesthesia [Internet].&nbsp; 2015 [citado 8  Ago. 2017];25:334&ndash;345. Disponible en: <a href="http://onlinelibrary.wiley.com/doi/10.1111/pan.12614/pdf" target="_blank">http://onlinelibrary.wiley.com/doi/10.1111/pan.12614/pdf</a> </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">12- Ramachandran KS, Kumar AM. Supraglottic Airway Devices. Respiratory Care [Internet]. 2014 [citado 8 Ago. 2017];59(6):920-931. Disponible  en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/24891199" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/24891199</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">13- Timmemann A. Supraglottic airways in difficult airway  management: successes, failures, use and misuse. Anaesthesia  [Internet]. 2011 [citado 8 Ago. 2017];66 (suppl. 2):45-56. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/22074079">http://www.ncbi.nlm.nih.gov/pubmed/22074079</a></font><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">14- Goyal R. Small is the new big: An overview of newer  supraglottic airways for children. J Anaesthesiol Clin Pharmacol [Internet]. 2015  Oct-Dec [citado 8 Ago. 2017];31(4): 440&ndash;449. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4676229/" target="_parent">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4676229/</a> </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">15- Shariffuddin II, Teoh WH, Tang E, Hashim N, Loh PS.  Ambu&reg; AuraGain&trade; versus LMA Supreme&trade; Second Seal&trade;: a randomised controlled trial  comparing oropharyngeal leak pressures and gastric drain functionality in  spontaneously breathing patients. Anaesth Intensive Care  [Internet]. 2017 Mar [citado 8 Ago. 2017];45(2):244-250. Disponible  en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/28267947" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/28267947</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">16- Cordero  Escobar I. La v&iacute;a a&eacute;rea y su abordaje. En: D&aacute;vila Cabo de Villa E.  Anestesiolog&iacute;a cl&iacute;nica. 2da.ed. La   Habana: Editoral Ciencias M&eacute;dicas; 2014. p. 87-97.    </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">17- Almeida G, Costa AC, Machado HS. Supraglottic Airway Devices: A Review in a New Era of  Airway Management. J Anesth Clin Res  [Internet]. 2006 [citado 8 Ago.  2017];7:647. Disponible en: <a href="http://www.omicsonline.org/open-access/supraglottic-airway-devices-a-review-in-a-new-era-of-airway-management-2155-6148-1000647.php?aid=77389" target="_blank">http://www.omicsonline.org/open-access/supraglottic-airway-devices-a-review-in-a-new-era-of-airway-management-2155-6148-1000647.php?aid=77389</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">18- Ge N, Guan M, Li X, Li S, Wang  EB. Application of flexible laryngeal mask airway in oral &amp; maxillofacial  day surgery. Beijing  Da Xue Xue Bao [Internet]. 2015 Dec. 18 [citado 8 Ago. 2017];47(6):1010-4.  Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/26679667" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/26679667</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">19- L&oacute;pez Correa T,&nbsp; Sastre JA, Garz&oacute;n JC. Blind  tracheal intubation through 2 supraglottic devices: the Ambu AuraGain vs the  LMA Fastrach. Emergencias  [Internet]. 2016 [citado 8 Ago.  2017];28:83-88. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/29105428" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/29105428</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">20- Sinha  A, Jayaraman L, Punhani D, Panigrahi B. ProSeal laryngeal mask airway improves  oxygenation when used as a conduit prior to laryngoscope guided intubation in  bariatric patients. Indian J Anaesth [Internet]. 2013 [citado 8 Ago. 2017];57:25-30.  Disponible en: <a href="http://www.ijaweb.org/article.asp?issn=0019-5049;year=2013;volume=57;issue=1;spage=25;epage=30;aulast=Sinha" target="_blank">http://www.ijaweb.org/article.asp?issn=0019-5049;year=2013;volume=57;issue=1;spage=25;epage=30;aulast=Sinha</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">21- van  Esch BF, Stegeman I, Smit AL. Comparison of laryngeal mask airway vs tracheal  intubation: a systematic review on airway complications. J Clin Anesth  [Internet]. 2017 Feb [citado 8 Ago. 2017];36:142-150. Disponible  en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/28183554" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/28183554</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">22- &Aacute;lvarez R&iacute;o JJ. Mascarilla  Lar&iacute;ngea. Revista Mex de Anestesiolog&iacute;a [Internet]. 2002 [citado 8 Ago.  2016];25(1). Disponible en: <a href="http://www.medigraphic.com/pdfs/rma/cma-2002/cma021k.pdf" target="_blank">http://www.medigraphic.com/pdfs/rma/cma-2002/cma021k.pdf</a> </font><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">23- Teleflex Medical. INSTRUCCIONES  DE USO &ndash; LMA Unique&trade; (Silicone Cuff) y LMA Unique&trade; (Silicone Cuff) Cuff Pilot&trade; [Internet].&nbsp; Irlanda: Teleflex Medical; 2015  [citado 8 Ago.  2017]. Disponible en:&nbsp; <a href="http://www.lmaco-ifu.com/sites/default/files/node/2278/ifu/revision/3462/pbq2104000aes.pdf" target="_blank">http://www.lmaco-ifu.com/sites/default/files/node/2278/ifu/revision/3462/pbq2104000aes.pdf</a> </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">24- Williams  DL, Zeng JM, Alexander KD, Andrews DT. Randomised Comparison of the AMBU  AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in  Spontaneously Breathing Adults. Anesthesiology Research and Practice  [Internet]. 2012 [citado 8 Ago. 2017]. Disponible en: <a href="http://www.hindawi.com/journals/arp/2012/405812/citations/" target="_blank">http://www.hindawi.com/journals/arp/2012/405812/citations/</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">25- Mariscal Flores M, Caro  Cascante M, V&aacute;squez Caicedo R. Mascarilla Lar&iacute;&shy;ngea AIR-Q [Internet]. Madrid:  Anestesiar; 2013 [citado 8 Ago. 2016]. Disponible en: <a href="file:///C:\Users\EDY\AppData\Local\Temp\RRA_GRALINDM2.pdf" target="_blank">http://anestesiar.org/2013/mascarilla-laringea-air-q/</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">26- Siddharam J, Liyakhath A, Manjunath M. A prospective  randomized study comparing the , the AMBU Aura40 Laryngeal MaskTM and the  I-GelTM using fiberoptic bronchoscope in spontaneously breathing anesthetized  patients. IAIM [Internet],  2015 [citado 8  Ago. 2017];2(7):105-115. Disponible en: <a href="http://oaji.net/journal-archive-stats.html?number=1398&year=2015&issue=4644" target="_blank">http://oaji.net/journal-archive-stats.html?number=1398&amp;year=2015&amp;issue=4644</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">27- Suzanna  AB, Liu CY, Rozaidi SW, Ooi JS. Comparison  between LMA-Classic and AMBU AuraOnce laryngeal mask airway in patients  undergoing elective general anaesthesia with positive pressure ventilation. Med  J Malaysia  [Internet]. 2011 Oct [citado 8 Ago. 2017];66(4):304-7. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/22299547" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/22299547</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">28- Baidya DK,&nbsp;  Darlong V, Pandey R, Maitra S, Khanna P. Comparative efficacy and safety  of the Ambu(&reg;) AuraOnce(&trade;) laryngeal mask airway during general anaesthesia in  adults: a systematic review and meta-analysis. Anaesthesia  [Internet].  2014 [citado 8  Ago. 2017];69(9):1023-32. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/24801012" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/24801012</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">29- Aqil M, Delvi B, Abujamea A, Alzahrani T, Alzahem A,  Mansoor S, et.al. Spatial relationship of i-gel&reg; and Ambu&reg; AuraOnceTM on  pediatric airway: a randomized comparison based on three dimensional magnetic  resonance imaging. Minerva Anestesiol [Internet]. 2017  Jan [citado 8  Ago. 2017];83(123-32). Disponible en: <a href="http://www.ncbi.nlm.nih.gov/m/pubmed/27314596/" target="_blank">http://www.ncbi.nlm.nih.gov/m/pubmed/27314596/</a></font><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">30- Singh M, Srivastava M, Kapoor D. AMBU-LM aura once&reg; in  management of difficult airway in post-radiotherapy oral burns patient admitted  in intensive care unit. J Anaesthesiol Clin Pharmacol [Internet]. 2014 Oct-Dec [citado 8  Ago. 2017];30(4):574&ndash;575. Disponible  en: <a href="http://www.joacp.org/article.asp?issn=0970-9185;year=2014;volume=30;issue=4;spage=574;epage=575;aulast=Singh" target="_blank">http://www.joacp.org/article.asp?issn=0970-9185;year=2014;volume=30;issue=4;spage=574;epage=575;aulast=Singh</a> </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">31- Sanuki T, Nakatani G, Sugioka S, Daigo E, Kotani J.  Comparison of the Ambu AuraFlex with the laryngeal mask airway Flexible: a  manikin study. Oral Maxillofac Surg [Internet]. 2011  Jul [citado 8  Ago. 2017];69(7):e269-72. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/21549471" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/21549471</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">32- Tominaga A, Ueshima H, Ariyama J, Kitamura A.  Successful intubation in a difficult case using an Ambu Laryngeal Mask Angle  Type-i, and the ability to pass a gastric tube behind the laryngeal mask.  Masui. 2014 May;63(5):545-7. Citado en Pub Med: PMID: 24864577.     </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">33- Pavoni V,&nbsp;&nbsp;  Froio V,&nbsp; Nella A,&nbsp; Simonelli M,&nbsp;  Gianesello L, Horton A, et.al. Tracheal Intubation with Aura-i and aScope-2:  How to Minimize Apnea Time in an Unpredicted Difficult Airway. Case Rep  Anesthesiol. 2015. Citado en Pub Med: PMID: 25632355.    </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">34- Zhi J, Deng XM, Yang D,  et.al.  Comparison of the Ambu Aura-i with the Air-Q Intubating Laryngeal Airway as A  Conduit for Fiberoptic-guided Tracheal Intubation in Children with Ear  Deformity. Zhongguo Yi Xue Ke Xue Yuan Xue Bao. 2016 Dec  20;38(6):637-642. Citado  en Pub Med: PMID: 28065228.    </font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">35- Jagannathan N, Hajduk J, Sohn L, Huang A, Sawardekar  A, Gebhardt ER, et.al. A randomised comparison of the Ambu&reg; AuraGain&trade; and the  LMA&reg; supreme in infants and children. Anaesthesia [Internet].  2016 Feb [citado  8 Ago. 2017];71(2):205-12. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/26648173" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/26648173</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">36- Attarde VB, Kotekar N, Shetty SM. Air-Q intubating  laryngeal airway: A study of the second generation supraglottic airway device. Indian J Anaesth [Internet]. 2016 May [citado 8  Ago. 2017];60(5):343-8. Disponible  en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/27212722" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/27212722</a> </font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">37- Jin Ahn E, Joo Choi G, Kang H, Wha Baek Ch, Hun Jung  Y,&nbsp; Cheol Woo Y, et al. Comparative  Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in  Pediatric Patients: A Systematic Review and Meta-Analysis. Bio Med Research  International [Internet].  2016 [citado 8 Ago. 2017]. Disponible en: <a href="http://www.hindawi.com/journals/bmri/2016/6406391/" target="_blank">http://www.hindawi.com/journals/bmri/2016/6406391/</a></font><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">38- van Zundert T,&nbsp;  Gatt S. The Baska Mask&reg;&mdash;A new concept in Self-sealing membrane cuff  extraglottic airway devices, using a sump and two gastric drains: A critical  evaluation. Journal of Obstetric Anaesthesia and Critical Care [Internet]. Jan-Jun 2012 [citado 8  Ago. 2017];2(1):23-30. Disponible  en: <a href="http://www.joacc.com/article.asp?issn=2249-4472;year=2012;volume=2;issue=1;spage=23;epage=30;aulast=Zundert" target="_blank">http://www.joacc.com/article.asp?issn=2249-4472;year=2012;volume=2;issue=1;spage=23;epage=30;aulast=Zundert</a></font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">39- L&oacute;pez  AM,&nbsp;&nbsp; Mu&ntilde;oz-Rojas G, Fontanal M,&nbsp; de San Jos&eacute; I,&nbsp; Hermoso A,&nbsp;  Valero R. Evaluaci&oacute;n cl&iacute;nica de la m&aacute;scara lar&iacute;ngea&nbsp; Baska Mask&reg; en pacientes adultos en cirug&iacute;a  ambulatoria. Revista Espa&ntilde;ola de Anestesiolog&iacute;a y Reanimaci&oacute;n [Internet].  2015 [citado 8  Ago. 2017];62(10):551-556. Disponible en: <a href="http://www.sciencedirect.com/science/article/pii/S0034935615000122" target="_blank">http://www.sciencedirect.com/science/article/pii/S0034935615000122</a></font><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">40- Klu&#269;ka J, &Scaron;toura&#269; P,&nbsp;  &Scaron;toudek R,&nbsp; &#356;ouk&aacute;lkov&aacute; M,&nbsp; Harazim H,&nbsp;  Kosinov&aacute; M. Controversies in Pediatric Perioperative Airways. Biomed  Res Int [Internet].  2015 [citado 8  Ago. 2017]. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/26759809">http://www.ncbi.nlm.nih.gov/pubmed/26759809</a></font></p>     <!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">41- Bele&ntilde;a J,&nbsp; Ochoa  E, N&uacute;&ntilde;ez M,&nbsp; Gilsanz C, Vidal A. Role of  laryngeal mask airway in laparoscopic cholecystectomy. World J Gastrointest  Surg [Internet]. 2015&nbsp; November  27 [citado 8  Ago. 2017];7(11):319-325. Disponible  en: <a href="http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4663386/" target="_blank">http://www.ncbi.nlm.nih.gov/pmc/articles/PMC4663386/</a></font><!-- ref --><p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">42- Anand LK, Goel N, Singh M, Kapoor D. Comparison of the  Supreme and ProSeal laryngeal Mask airway in patients undergoing laparoscopic  cholecystectomy: a randmonized controlled trial. Acta  Anaesthesiol Taiw&aacute;n [Internet].&nbsp;2016 Jun [citado 8 Ago. 2017];54(2):44-50. Disponible en: <a href="http://www.ncbi.nlm.nih.gov/pubmed/27106162" target="_blank">http://www.ncbi.nlm.nih.gov/pubmed/27106162</a> </font><p align="left">&nbsp;</p>     <p align="left">&nbsp;</p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Recibido: 30/2/17    <br> Aprobado: 7/2/18</font></p>     <p align="left">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="left">&nbsp;</p>     <p align="left"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><em>Israel Gonzalez de Pino</em>. Hospital Universit&aacute;rio  Pedi&aacute;trico Eliseo Noel Caama&ntilde;o. Matanzas.Calle Santa Isabel esquina  Compostela.Matanzas    <br>   Correo electr&oacute;nico: <a href="mailto:israel.mtz@infomed.sld.cu">israel.mtz@infomed.sld.cu</a></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cordero Escobar]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<source><![CDATA[Anestesiología. Criterios y tendencias actuales]]></source>
<year>2013</year>
<publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yahaya]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Teoh]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Dintan]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Agrawal]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The AMBU® Aura-i™ Laryngeal Mask and LMA Supreme™: A Randomized Trial of Clinical Performance and Fibreoptic Positioning in Unparalysed, Anaesthetised Patients by Novices]]></article-title>
<source><![CDATA[Anesthesiol Res Pract]]></source>
<year>2016</year>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beleña]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Gasco]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Polo]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Laryngeal mask, laryngeal tube, and frova introducer in simulated difficult airway]]></article-title>
<source><![CDATA[J Emerg Med]]></source>
<year>2015</year>
<volume>48</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>254-9</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Nicholson]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cook]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
<name>
<surname><![CDATA[Smith]]></surname>
<given-names><![CDATA[AF]]></given-names>
</name>
<name>
<surname><![CDATA[Lewis]]></surname>
<given-names><![CDATA[SR]]></given-names>
</name>
<name>
<surname><![CDATA[Reed]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Supraglottic airway devices versus tracheal intubation for airway management during general anaesthesia in obese patients]]></article-title>
<source><![CDATA[Cochrane Database Syst Rev]]></source>
<year>2013</year>
<month> S</month>
<day>ep</day>
<volume>9</volume>
<numero>9</numero>
<issue>9</issue>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Siddharam]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Anuradha]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ramesh]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[I - Gel Versus Cuffed Tracheal Tube in Elective Laparoscopic Cholecystectomy - A Clinical Comparative Study]]></article-title>
<source><![CDATA[Indian Journal of Clinical Anaesthesia]]></source>
<year>2015</year>
<volume>2</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>235-239</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Dwivedi]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Nagrale]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Dwivedi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Singh]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[What happens to the hemodynamic responses for laryngeal mask airway insertion when we supplement propofol with butorphanol or fentanyl for induction of anesthesia: A comparative assessment and critical review]]></article-title>
<source><![CDATA[Int J Crit Illn Inj Sci]]></source>
<year>2016</year>
<volume>6</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>40-44</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karišik]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simple, timely, safely? Laryngeal mask and pediatric airway]]></article-title>
<source><![CDATA[Acta Clin Croat]]></source>
<year>2016</year>
<month> M</month>
<day>ar</day>
<volume>55</volume>
<numero>^s1</numero>
<issue>^s1</issue>
<supplement>1</supplement>
<page-range>55-61</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
<name>
<surname><![CDATA[Klock]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ovassapian]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evolution of the Extraglottic Airway: A Review of Its History, Applications, and Practical Tips for Success]]></article-title>
<source><![CDATA[Anesth Analg]]></source>
<year>2012</year>
<volume>114</volume>
<page-range>349-68</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Rodríguez Ramírez]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Bermúdez Bermúdez]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
<name>
<surname><![CDATA[Cordero Escobar]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Abela Lazo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Máscara laríngea I Gel vs ProSeal en cirugía oncológica de mama]]></article-title>
<source><![CDATA[Revista Cubana de Anestesiología y Reanimación]]></source>
<year>2014</year>
<volume>13</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>15-30</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martínez Hurtado]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez Merchante]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Nuevas mascarillas laríngeas, la tercera generación]]></article-title>
<source><![CDATA[Anestesiar.org]]></source>
<year>2015</year>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jagannathan]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Ramsey]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[White]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Sohn]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An update on newer pediatric supraglottic airways with recommendations for clinical use]]></article-title>
<source><![CDATA[Pediatric Anesthesia]]></source>
<year>2015</year>
<volume>25</volume>
<page-range>334-345</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramachandran]]></surname>
<given-names><![CDATA[KS]]></given-names>
</name>
<name>
<surname><![CDATA[Kumar]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Supraglottic Airway Devices]]></article-title>
<source><![CDATA[Respiratory Care]]></source>
<year>2014</year>
<volume>59</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>920-931</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Timmemann]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Supraglottic airways in difficult airway management: successes, failures, use and misuse]]></article-title>
<source><![CDATA[Anaesthesia]]></source>
<year>2011</year>
<volume>66</volume>
<numero>^s2</numero>
<issue>^s2</issue>
<supplement>2</supplement>
<page-range>45-56</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goyal]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Small is the new big: An overview of newer supraglottic airways for children]]></article-title>
<source><![CDATA[J Anaesthesiol Clin Pharmacol]]></source>
<year>2015</year>
<volume>31</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>440-449</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shariffuddin]]></surname>
<given-names><![CDATA[II]]></given-names>
</name>
<name>
<surname><![CDATA[Teoh]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Tang]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Hashim]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Loh]]></surname>
<given-names><![CDATA[PS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Ambu® AuraGain™ versus LMA Supreme™ Second Seal™: a randomised controlled trial comparing oropharyngeal leak pressures and gastric drain functionality in spontaneously breathing patients]]></article-title>
<source><![CDATA[Anaesth Intensive Care]]></source>
<year>2017</year>
<month> M</month>
<day>ar</day>
<volume>45</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>244-250</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cordero Escobar]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La vía aérea y su abordaje]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Dávila Cabo de Villa]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<source><![CDATA[Anestesiología clínica]]></source>
<year>2014</year>
<edition>2</edition>
<page-range>87-97</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Editoral Ciencias Médicas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Almeida]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Costa]]></surname>
<given-names><![CDATA[AC]]></given-names>
</name>
<name>
<surname><![CDATA[Machado]]></surname>
<given-names><![CDATA[HS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Supraglottic Airway Devices: A Review in a New Era of Airway Management]]></article-title>
<source><![CDATA[J Anesth Clin Res]]></source>
<year>2006</year>
<volume>7</volume>
<page-range>647</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ge]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Guan]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[EB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Application of flexible laryngeal mask airway in oral & maxillofacial day surgery]]></article-title>
<source><![CDATA[Beijing Da Xue Xue Bao]]></source>
<year>2015</year>
<month> D</month>
<day>ec</day>
<volume>47</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1010-4</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[López Correa]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Sastre]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Garzón]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Blind tracheal intubation through 2 supraglottic devices: the Ambu AuraGain vs the LMA Fastrach]]></article-title>
<source><![CDATA[Emergencias]]></source>
<year>2016</year>
<volume>28</volume>
<page-range>83-88</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sinha]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Jayaraman]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Punhani]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Panigrahi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[ProSeal laryngeal mask airway improves oxygenation when used as a conduit prior to laryngoscope guided intubation in bariatric patients]]></article-title>
<source><![CDATA[Indian J Anaesth]]></source>
<year>2013</year>
<volume>57</volume>
<page-range>25-30</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Esch]]></surname>
<given-names><![CDATA[BF]]></given-names>
</name>
<name>
<surname><![CDATA[Stegeman]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Smit]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of laryngeal mask airway vs tracheal intubation: a systematic review on airway complications]]></article-title>
<source><![CDATA[J Clin Anesth]]></source>
<year>2017</year>
<month> F</month>
<day>eb</day>
<volume>36</volume>
<page-range>142-150</page-range></nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Álvarez Río]]></surname>
<given-names><![CDATA[JJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Mascarilla Laríngea]]></article-title>
<source><![CDATA[Revista Mex de Anestesiología]]></source>
<year>2002</year>
<volume>25</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="book">
<collab>Teleflex Medical</collab>
<source><![CDATA[INSTRUCCIONES DE USO - LMA Unique™ (Silicone Cuff) y LMA Unique™ (Silicone Cuff) Cuff Pilot™]]></source>
<year>2015</year>
<publisher-name><![CDATA[Teleflex Medical]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Williams]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Zeng]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Alexander]]></surname>
<given-names><![CDATA[KD]]></given-names>
</name>
<name>
<surname><![CDATA[Andrews]]></surname>
<given-names><![CDATA[DT]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Randomised Comparison of the AMBU AuraOnce Laryngeal Mask and the LMA Unique Laryngeal Mask Airway in Spontaneously Breathing Adults]]></article-title>
<source><![CDATA[Anesthesiology Research and Practice]]></source>
<year>2012</year>
</nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mariscal Flores]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Caro Cascante]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Vásquez Caicedo]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<source><![CDATA[Mascarilla Larí­ngea AIR-Q]]></source>
<year>2013</year>
<publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Anestesiar]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Siddharam]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Liyakhath]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Manjunath]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A prospective randomized study comparing the , the AMBU Aura40 Laryngeal MaskTM and the I-GelTM using fiberoptic bronchoscope in spontaneously breathing anesthetized patients]]></article-title>
<source><![CDATA[IAIM]]></source>
<year>2015</year>
<volume>2</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>105-115</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Suzanna]]></surname>
<given-names><![CDATA[AB]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[CY]]></given-names>
</name>
<name>
<surname><![CDATA[Rozaidi]]></surname>
<given-names><![CDATA[SW]]></given-names>
</name>
<name>
<surname><![CDATA[Ooi]]></surname>
<given-names><![CDATA[JS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison between LMA-Classic and AMBU AuraOnce laryngeal mask airway in patients undergoing elective general anaesthesia with positive pressure ventilation]]></article-title>
<source><![CDATA[Med J Malaysia]]></source>
<year>2011</year>
<month> O</month>
<day>ct</day>
<volume>66</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>304-7</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baidya]]></surname>
<given-names><![CDATA[DK]]></given-names>
</name>
<name>
<surname><![CDATA[Darlong]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Pandey]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Maitra]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Khanna]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative efficacy and safety of the Ambu(®) AuraOnce(™) laryngeal mask airway during general anaesthesia in adults: a systematic review and meta-analysis]]></article-title>
<source><![CDATA[Anaesthesia]]></source>
<year>2014</year>
<volume>69</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1023-32</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Aqil]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Delvi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Abujamea]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Alzahrani]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Alzahem]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Mansoor]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Spatial relationship of i-gel® and Ambu® AuraOnceTM on pediatric airway: a randomized comparison based on three dimensional magnetic resonance imaging]]></article-title>
<source><![CDATA[Minerva Anestesiol]]></source>
<year>2017</year>
<month> J</month>
<day>an</day>
<volume>83</volume>
<numero>123-32</numero>
<issue>123-32</issue>
</nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Singh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Srivastava]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kapoor]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[AMBU-LM aura once® in management of difficult airway in post-radiotherapy oral burns patient admitted in intensive care unit]]></article-title>
<source><![CDATA[J Anaesthesiol Clin Pharmacol]]></source>
<year>2014</year>
<volume>30</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>574-575</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sanuki]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Nakatani]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Sugioka]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Daigo]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Kotani]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of the Ambu AuraFlex with the laryngeal mask airway Flexible: a manikin study]]></article-title>
<source><![CDATA[Oral Maxillofac Surg]]></source>
<year>2011</year>
<month> J</month>
<day>ul</day>
<volume>69</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>e269-72</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tominaga]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Ueshima]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ariyama]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Kitamura]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Successful intubation in a difficult case using an Ambu Laryngeal Mask Angle Type-i, and the ability to pass a gastric tube behind the laryngeal mask]]></article-title>
<source><![CDATA[Masui]]></source>
<year>2014</year>
<month> M</month>
<day>ay</day>
<volume>63</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>545-7</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pavoni]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Froio]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Nella]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Simonelli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gianesello]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Horton]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Tracheal Intubation with Aura-i and aScope-2: How to Minimize Apnea Time in an Unpredicted Difficult Airway]]></article-title>
<source><![CDATA[Case Rep Anesthesiol]]></source>
<year>2015</year>
</nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Deng]]></surname>
<given-names><![CDATA[XM]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of the Ambu Aura-i with the Air-Q Intubating Laryngeal Airway as A Conduit for Fiberoptic-guided Tracheal Intubation in Children with Ear Deformity]]></article-title>
<source><![CDATA[Zhongguo Yi Xue Ke Xue Yuan Xue Bao]]></source>
<year>2016</year>
<month> D</month>
<day>ec</day>
<volume>38</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>637-642</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jagannathan]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Hajduk]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Sohn]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Huang]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sawardekar]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Gebhardt]]></surname>
<given-names><![CDATA[ER]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A randomised comparison of the Ambu® AuraGain™ and the LMA® supreme in infants and children]]></article-title>
<source><![CDATA[Anaesthesia]]></source>
<year>2016</year>
<month> F</month>
<day>eb</day>
<volume>71</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>205-12</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Attarde]]></surname>
<given-names><![CDATA[VB]]></given-names>
</name>
<name>
<surname><![CDATA[Kotekar]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Shetty]]></surname>
<given-names><![CDATA[SM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Air-Q intubating laryngeal airway: A study of the second generation supraglottic airway device]]></article-title>
<source><![CDATA[Indian J Anaesth]]></source>
<year>2016</year>
<month> M</month>
<day>ay</day>
<volume>60</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>343-8</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jin Ahn]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Joo Choi]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Kang]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Ch]]></surname>
<given-names><![CDATA[Wha Baek]]></given-names>
</name>
<name>
<surname><![CDATA[Hun Jung]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Cheol Woo]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparative Efficacy of the Air-Q Intubating Laryngeal Airway during General Anesthesia in Pediatric Patients: A Systematic Review and Meta-Analysis]]></article-title>
<source><![CDATA[Bio Med Research International]]></source>
<year>2016</year>
</nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Zundert]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Gatt]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Baska Mask®-A new concept in Self-sealing membrane cuff extraglottic airway devices, using a sump and two gastric drains: A critical evaluation]]></article-title>
<source><![CDATA[Journal of Obstetric Anaesthesia and Critical Care]]></source>
<year>2012</year>
<volume>2</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>23-30</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[López]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz-Rojas]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Fontanal]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[de San José]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Hermoso]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Valero]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Evaluación clínica de la máscara laríngea Baska Mask® en pacientes adultos en cirugía ambulatoria]]></article-title>
<source><![CDATA[Revista Española de Anestesiología y Reanimación]]></source>
<year>2015</year>
<volume>62</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>551-556</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Klu&#269;ka]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Štoura&#269;]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Štoudek]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[&#356;oukálková]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Harazim]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Kosinová]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Controversies in Pediatric Perioperative Airways]]></article-title>
<source><![CDATA[Biomed Res Int]]></source>
<year>2015</year>
</nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Beleña]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Ochoa]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Núñez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gilsanz]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Vidal]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Role of laryngeal mask airway in laparoscopic cholecystectomy]]></article-title>
<source><![CDATA[World J Gastrointest Surg]]></source>
<year>2015</year>
<month> N</month>
<day>ov</day>
<volume>7</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>319-325</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Anand]]></surname>
<given-names><![CDATA[LK]]></given-names>
</name>
<name>
<surname><![CDATA[Goel]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Singh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kapoor]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Comparison of the Supreme and ProSeal laryngeal Mask airway in patients undergoing laparoscopic cholecystectomy: a randmonized controlled trial]]></article-title>
<source><![CDATA[Acta Anaesthesiol Taiwán]]></source>
<year>2016</year>
<month> J</month>
<day>un</day>
<volume>54</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>44-50</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
