<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1727-897X</journal-id>
<journal-title><![CDATA[MediSur]]></journal-title>
<abbrev-journal-title><![CDATA[Medisur]]></abbrev-journal-title>
<issn>1727-897X</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Ciencias Médicas de Cienfuegos, Centro Provincial de Ciencias Médicas, Provincia de Cienfuegos.]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1727-897X2022000200272</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Calidad de la imagen de tomografía computarizada versus dosis en estudios híbridos: resultados preliminares en maniquí]]></article-title>
<article-title xml:lang="en"><![CDATA[Quality of computed tomography image versus dose in hybrid studies: preliminary results in manikin]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López Díaz*]]></surname>
<given-names><![CDATA[Adlin]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[del Pozo Almaguer]]></surname>
<given-names><![CDATA[Armando]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Machado Tejeda]]></surname>
<given-names><![CDATA[Adalberto]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Batista Ramó]]></surname>
<given-names><![CDATA[Karla]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Calderón Marín]]></surname>
<given-names><![CDATA[Carlos F.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Torres Aroche]]></surname>
<given-names><![CDATA[Leonel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Instituto Superior de Ciencias y Tecnologías Aplicadas  ]]></institution>
<addr-line><![CDATA[La Hababa ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Instituto Nacional de Hematología e Inmunología  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Centro para el Control Estatal de Medicamentos, Equipos y Dispositivos Médicos  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Dirección de Investigaciones Biomédicas. Centro de Isótopos  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af5">
<institution><![CDATA[,Instituto Nacional de Oncología y Radiobiología  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>04</month>
<year>2022</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>04</month>
<year>2022</year>
</pub-date>
<volume>20</volume>
<numero>2</numero>
<fpage>272</fpage>
<lpage>284</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1727-897X2022000200272&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1727-897X2022000200272&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1727-897X2022000200272&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN  Fundamento:  los estudios híbridos producen una dosis total de radiación que es resultado de la dosis proveniente del radiofármaco y la emitida por la tomografía computarizada, por eso la optimización es indispensable.  Objetivo:  evaluar la relación de la dosis de tomografía computarizada con algunos parámetros de calidad de la imagen en protocolos de estudios híbridos.  Métodos:  para evaluar la calidad de la imagen se emplearon los maniquíes de Catphan y de Livermore en 12 protocolos preestablecidos de un equipo de tomografía por emisión del fotón único Mediso. Los datos de los descriptores de dosis de cada estudio se obtuvieron del cabezal DICOM. Se compararon los parámetros de calidad de imagen clásicos como ruido y la MTF 50 % para el maniquí de Catphan, y otros como la relación contraste ruido, el promedio de números de Hounsfield y su desviación estándar en las regiones de interés de los órganos correspondientes, en el maniquí de Livermore. Se analizó la relación de estos parámetros de calidad con los descriptores de dosis de los diferentes protocolos.  Resultados:  los parámetros relacionados con la calidad en el maniquí de Catphan no mostraron diferencias significativas (p&lt;0,05) entre los diferentes protocolos para estudios híbridos. Se encontraron diferencias significativas entre los protocolos clínicos con diferentes calidades y el protocolo clínico estándar, para el maniquí antropomórfico, en la desviación estándar de los números de Hounsfield y en la relación contraste ruido (p&lt;0,05).  Conclusiones:  el estudio de la relación contraste ruido y la desviación de los números de tomografía computarizada en las regiones de interés pueden servir de parámetro cuantitativo para la optimización de dosis en escenario clínico.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT  Background:  hybrid studies produce a total radiation dose that is the result of the dose imparted by the radiopharmaceutical and that emitted by the computed tomography, therefore optimization is essential.  Objective:  to evaluate the relationship of the computed tomography dose with some image quality parameters in hybrid study protocols.  Methods:  to evaluate the image quality, the Catphan and Livermore Phantom were used in 12 pre-established protocols of a Mediso single photon emission tomography equipment. The data for the dose descriptors for each study were obtained from the DICOM head. The classic image quality parameters such as noise and the MTF 50% for the Catphan manikin, and others such as the contrast-noise ratio, the average of Hounsfield numbers and their standard deviation in the regions of interest of the corresponding organs were compared, in Livermore's mannequin. The relationship of these quality parameters with the dose descriptors of the different protocols was analyzed.  Results:  the quality-related parameters in the Catphan manikin did not show significant differences (p &lt;0.05) between the different protocols for hybrid studies. Significant differences were found between the clinical protocols with different qualities and the standard clinical protocol, for the anthropomorphic manikin, in the standard deviation of the Hounsfield numbers and in the contrast-to-noise ratio (p &lt;0.05).  Conclusions:  the study of the contrast noise ratio and the deviation of the computed tomography numbers in the regions of interest can serve as a quantitative parameter for the optimization of doses in the clinical setting.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[dosis de radiación]]></kwd>
<kwd lng="es"><![CDATA[tomografía]]></kwd>
<kwd lng="es"><![CDATA[tomografía computarizada axial por emisión de fotón simple]]></kwd>
<kwd lng="en"><![CDATA[radiation dosage]]></kwd>
<kwd lng="en"><![CDATA[tomography]]></kwd>
<kwd lng="en"><![CDATA[tomography, emission-computed, single-photon]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bebbington]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Haddock]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Bertilsson]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Hippeläinen]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Husby]]></surname>
<given-names><![CDATA[HM]]></given-names>
</name>
<name>
<surname><![CDATA[Tunninen]]></surname>
<given-names><![CDATA[VI]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A Nordic survey of CT doses in hybrid PET/CT and SPECT/CT examinations]]></article-title>
<source><![CDATA[EJNMMI Physics]]></source>
<year>2019</year>
<page-range>6:24</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<collab>International Atomic Energy Agency</collab>
<source><![CDATA[Radiation protection and safety in medical uses of ionizing radiation]]></source>
<year>2018</year>
<publisher-loc><![CDATA[Viena ]]></publisher-loc>
<publisher-name><![CDATA[IAEA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brindhaban]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effective Dose to Patients from SPECT and CT During Myocardial Perfusion Imaging]]></article-title>
<source><![CDATA[J Nucl Med Technol]]></source>
<year>2020</year>
<volume>2020</volume>
<numero>48</numero>
<issue>48</issue>
<page-range>143-7</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Katarian]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Althénb]]></surname>
<given-names><![CDATA[JN]]></given-names>
</name>
<name>
<surname><![CDATA[Smedbyc]]></surname>
<given-names><![CDATA[Ö]]></given-names>
</name>
<name>
<surname><![CDATA[Perssona]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Sökjerd]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Sandborg]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Assessment of image quality in abdominal computed tomography Effect of model-based iterative reconstruction, multi-planar reconstruction and slice thickness on potential dose reduction]]></article-title>
<source><![CDATA[Eur J Radiol]]></source>
<year>2020</year>
<volume>122</volume>
<page-range>108703</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Njiki]]></surname>
<given-names><![CDATA[CD]]></given-names>
</name>
<name>
<surname><![CDATA[Ndjaka Manyol]]></surname>
<given-names><![CDATA[JEM]]></given-names>
</name>
<name>
<surname><![CDATA[Ebele Yigbedeck]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Assessment of Image Quality Parameters for Computed Tomography in the City of Yaound]]></article-title>
<collab>William Abou'ou D.Clovis Yimele B.Sabouang JF</collab>
<source><![CDATA[Open Journal of Radiology]]></source>
<year>2018</year>
<volume>8</volume>
<page-range>37-44</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Verdun]]></surname>
<given-names><![CDATA[FR]]></given-names>
</name>
<name>
<surname><![CDATA[Racine]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ott]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Tapiovaara]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[Toroi]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Bochud]]></surname>
<given-names><![CDATA[FO]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Image quality in CT From physical measurements to model observers]]></article-title>
<source><![CDATA[Phys Med]]></source>
<year>2015</year>
<volume>31</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>823-43</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="book">
<collab>Centro para el Control Estatal de Medicamentos</collab>
<source><![CDATA[Equipos y Dispositivos Médicos. Resolución 43/2021. Disposición reguladora E 95-21: Protocolo para el Control de Calidad a Equipos de Tomografía Computarizada]]></source>
<year>2021</year>
<publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[CECMED]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barca]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Paolicchi]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Aringhieri]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Palmas]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Marfisi]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Fantacci]]></surname>
<given-names><![CDATA[ME]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A comprehensive assessment of physical image quality of five different scanners for head CT imaging as clinically used at a single hospital centre-A phantom study]]></article-title>
<source><![CDATA[PLoS ONE]]></source>
<year>2021</year>
<volume>16</volume>
<numero>1</numero>
<issue>1</issue>
</nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gharbi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Labidi]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Mars]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Chelli]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Meftah]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Ladeb]]></surname>
<given-names><![CDATA[MF]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Assessment of organ dose and image quality in head and chest CT examinations a phantom study]]></article-title>
<source><![CDATA[J. Radiol Prot]]></source>
<year>2018</year>
<volume>38</volume>
<page-range>807-18</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Grosser]]></surname>
<given-names><![CDATA[OS]]></given-names>
</name>
<name>
<surname><![CDATA[Kupitz]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Ruf]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Czuczwara]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Steffen]]></surname>
<given-names><![CDATA[IG]]></given-names>
</name>
<name>
<surname><![CDATA[Furth]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Optimization of SPECT-CT Hybrid Imaging Using Iterative Image Reconstruction for Low-Dose CT A Phantom Study]]></article-title>
<source><![CDATA[PLoS ONE]]></source>
<year>2015</year>
<volume>10</volume>
<numero>9</numero>
<issue>9</issue>
</nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Baek Lee]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Woo Goo]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Quantitative Image Quality and Histogram-Based Evaluations of an Iterative Reconstruction Algorithm at Low-to-Ultralow Radiation Dose Levels A Phantom Study in Chest CT]]></article-title>
<source><![CDATA[Korean J Radiol]]></source>
<year>2018</year>
<volume>19</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>119-29</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muhammad]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Kayun]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Abu Hassan]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Wong]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Ng]]></surname>
<given-names><![CDATA[KH]]></given-names>
</name>
<name>
<surname><![CDATA[Karim]]></surname>
<given-names><![CDATA[MK]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evaluation of Organ Dose and Image Quality Metrics of Pediatric CT Chest Abdomen-Pelvis (CAP) Examination An Anthropomorphic Phantom Study]]></article-title>
<source><![CDATA[Appl Sci]]></source>
<year>2021</year>
<volume>11</volume>
<page-range>2047</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jagoda]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dzierma]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Ziegenhain]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Speicher]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Rübe]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Buecker]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Establishment of Submillisievert Abdominal CT Protocols With an In Vivo Swine Model and an Anthropomorphic Phantom]]></article-title>
<source><![CDATA[AJR]]></source>
<year>2020</year>
<volume>215</volume>
<page-range>685-94</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jensen]]></surname>
<given-names><![CDATA[JT]]></given-names>
</name>
<name>
<surname><![CDATA[Telesmanich]]></surname>
<given-names><![CDATA[ME]]></given-names>
</name>
<name>
<surname><![CDATA[Wagner-Bartak]]></surname>
<given-names><![CDATA[NA]]></given-names>
</name>
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Rong]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Szklaruk]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Based Iterative Reconstruction valuation of Abdominal CT Image Quality Using a New Version of Vendor-Specific Model]]></article-title>
<source><![CDATA[J Comput Assist Tomogr]]></source>
<year>2017</year>
<volume>41</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>67-74</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>