<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1815-5944</journal-id>
<journal-title><![CDATA[Ingeniería Mecánica]]></journal-title>
<abbrev-journal-title><![CDATA[Ingeniería Mecánica]]></abbrev-journal-title>
<issn>1815-5944</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería Mecánica. Instituto Superior Politécnico "José Antonio Echeverría"]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1815-59442014000200005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Revisión del cálculo del coeficiente de traspaso de calor en ebullición en minicanales y microcanales]]></article-title>
<article-title xml:lang="en"><![CDATA[Review of heat transfer coefficient calculation in boiling in minichannels and microchannels]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cisneros-Ramírez]]></surname>
<given-names><![CDATA[César-Arnaldo]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Instituto Superior Politécnico José Antonio Echeverría , Centro de Estudios de Tecnologías Energéticas Renovables, CETER ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>08</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>08</month>
<year>2014</year>
</pub-date>
<volume>17</volume>
<numero>2</numero>
<fpage>138</fpage>
<lpage>146</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1815-59442014000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1815-59442014000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1815-59442014000200005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La necesidad de disipar altas densidades de flujo de calor ha llevado a los investigadores y diseñadores a emplear el cambio de fase como mecanismo para lograr tal objetivo y con ello lograr equipos intercambiadores de calor más compactos. En el presente trabajo se realizó un estudio de la bibliográfica sobre la ebullición en minicanales y microcanales. Para ello se consultaron bibliografías que datan desde los años 90 hasta la actualidad, con lo cual se revelaron los principales parámetros o tópicos que caracterizan a este proceso en minicanales y microcanales. Es así que se abordan los términos minicanales y microcanales, ebullición en flujo forzado y regímenes (mapa) de flujo. Además se presenta un resumen de las ecuaciones para la determinación del coeficiente de traspaso de calor en régimen bifásico (h df).]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The necessity of transfer high heat flux had led to researchers and designers to use the change of phase in order to get this objective. In this work was made a review in more of seventy sources of information dating since 90´s up to the present, where were revealed the main parameters that characterize the boiling process in minichanels-microchannels. It deals with terms mini-microchannels, flow boiling and flow pattern map. Also, it is presented a summary of equations used for calculate the two-phase heat transfer coefficient.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[ebullición]]></kwd>
<kwd lng="es"><![CDATA[microcanales]]></kwd>
<kwd lng="es"><![CDATA[minicanales]]></kwd>
<kwd lng="es"><![CDATA[coeficiente de traspaso de calor]]></kwd>
<kwd lng="en"><![CDATA[boiling]]></kwd>
<kwd lng="en"><![CDATA[minichannels]]></kwd>
<kwd lng="en"><![CDATA[microchannels]]></kwd>
<kwd lng="en"><![CDATA[heat transfer coefficient]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <div align="right">       <p><b><font face="Verdana" size="2">ART&Iacute;CULO DE REVISI&Oacute;N</font></b></p>       <p>&nbsp; </p> </div>     <P><font face="Verdana" size="4"><b>Revisi&oacute;n del c&aacute;lculo del coeficiente    de traspaso de calor en ebullici&oacute;n en minicanales y microcanales </b></font>     <P>&nbsp;     <P><font face="Verdana" size="2"><b><font size="3">Review of heat transfer coefficient    calculation in boiling in minichannels and microchannels </font></b></font>     <P>&nbsp;     <P>&nbsp;      <P><font face="Verdana" size="2"><b>C&eacute;sar-Arnaldo Cisneros-Ram&iacute;rez    </b> </font>     <P><font face="Verdana" size="2">Instituto Superior Polit&eacute;cnico Jos&eacute;    Antonio Echeverr&iacute;a, Centro de Estudios de Tecnolog&iacute;as Energ&eacute;ticas    Renovables, CETER, La Habana. Cuba<b> </b></font>     ]]></body>
<body><![CDATA[<P>&nbsp;     <P>&nbsp; <hr>     <P><font face="Verdana" size="2"><b>RESUMEN</b></font>     <P><font face="Verdana" size="2">La necesidad de disipar altas densidades de flujo    de calor ha llevado a los investigadores y dise&ntilde;adores a emplear el cambio    de fase como mecanismo para lograr tal objetivo y con ello lograr equipos intercambiadores    de calor m&aacute;s compactos. En el presente trabajo se realiz&oacute; un estudio    de la bibliogr&aacute;fica sobre la ebullici&oacute;n en minicanales y microcanales.    Para ello se consultaron bibliograf&iacute;as que datan desde los a&ntilde;os    90 hasta la actualidad, con lo cual se revelaron los principales par&aacute;metros    o t&oacute;picos que caracterizan a este proceso en minicanales y microcanales.    Es as&iacute; que se abordan los t&eacute;rminos minicanales y microcanales,    ebullici&oacute;n en flujo forzado y reg&iacute;menes (mapa) de flujo. Adem&aacute;s    se presenta un resumen de las ecuaciones para la determinaci&oacute;n del coeficiente    de traspaso de calor en r&eacute;gimen bif&aacute;sico (h<sub>df</sub>). </font>      <P><font face="Verdana" size="2"><b>Palabras claves:</b> ebullici&oacute;n, microcanales,    minicanales, coeficiente de traspaso de calor. </font> <hr>     <P><font face="Verdana" size="2"><b>ABSTRACT</b></font>     <P><font face="Verdana" size="2">The necessity of transfer high heat flux had    led to researchers and designers to use the change of phase in order to get    this objective. In this work was made a review in more of seventy sources of    information dating since 90&#180;s up to the present, where were revealed the    main parameters that characterize the boiling process in minichanels-microchannels.    It deals with terms mini-microchannels, flow boiling and flow pattern map. Also,    it is presented a summary of equations used for calculate the two-phase heat    transfer coefficient. </font>     <P><font face="Verdana" size="2"><b>Key words:</b> boiling, minichannels, microchannels,    heat transfer coefficient. </font> <hr>     <P>&nbsp;     <P><font face="Verdana" size="3"><b>INTRODUCCI&Oacute;N</b></font>     ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">La necesidad de disipar altas densidades de flujo    de calor mediante flujo de aire, ha forzado a los dise&ntilde;adores a considerar    el enfriamiento con l&iacute;quido sin cambio de fase como una opci&oacute;n.    La otra opci&oacute;n ha sido emplear el cambio de fase para este fin, es decir,    el empleo de ebullici&oacute;n en canales de peque&ntilde;os di&aacute;metros.    Los tubos cal&oacute;ricos, celdas combustibles, evaporadores compactos de avanzados    dise&ntilde;os, entre otros, son equipos o aparatos que emplean canales de di&aacute;metro    hidr&aacute;ulico del orden de 1 mm. Fueron Tuckerman y Pease [1] quienes demostraron    experimentalmente que una densidad de flujo de calor (q<sub>p</sub>) de 1300    W/cm<sup>2</sup> puede ser disipada mientras se mantiene una diferencia de temperatura    menor de 70 &ordm;C </font>      <P><font face="Verdana" size="2">Es por ello que la ebullici&oacute;n en minicanales    y microcanales tiene gran expectativa para obtener una efectiva disipaci&oacute;n    de calor, fundamentalmente en equipos de peque&ntilde;as dimensiones [2], de    aqu&iacute; que esta l&iacute;nea de investigaci&oacute;n ha tomado inter&eacute;s    fundamentalmente cuando se necesita disipar altas densidades de flujo de calor    en equipos electr&oacute;nicos entre otros usos [3, 4] </font>     <P><font face="Verdana" size="2">Shah [5] defini&oacute; el intercambiador compacto    como aquel que tiene una relaci&oacute;n &aacute;rea a volumen igual o mayor    a 700 m<sup>2</sup>/m<sup>3</sup>. Muchas de las t&eacute;cnicas de fabricaci&oacute;n    de circuitos electr&oacute;nicos son utilizadas en la fabricaci&oacute;n de    intercambiadores compactos. Los minicanales y microcanales constituyen una nueva    tecnolog&iacute;a en la disipaci&oacute;n de grandes densidades de energ&iacute;a    a trav&eacute;s de peque&ntilde;as &aacute;reas. Estos son una alternativa para    la sustituci&oacute;n de intercambiadores aletados convencionales utilizados    fundamentalmente en la industria automovil&iacute;stica, del aire acondicionado    y refrigeraci&oacute;n entre otras. Una superficie de minicanales y microcanales    normalmente est&aacute; formado por varios de estos elementos en paralelo [6].    El medio de enfriamiento circula por esos canales con el objetivo de extraer    el calor de la fuente energ&eacute;tica, teniendo como caracter&iacute;stica    que el flujo es laminar. Adem&aacute;s, en una superficie de este tipo se obtienen    altos valores de coeficiente de traspaso de calor, alta relaci&oacute;n &aacute;rea/volumen,    peque&ntilde;a masa y volumen y se necesita peque&ntilde;a cantidad del medio    o agente de enfriamiento </font>      <P><font face="Verdana" size="2">En un intercambiador constituido por minicanales    y microcanales la transferencia de calor se mejora en dos v&iacute;as: primero,    por las peque&ntilde;as dimensiones de los conductos se incrementa el coeficiente    de traspaso de calor y segundo, por la orientaci&oacute;n plana que experimentan    los conductos se reduce la resistencia sobre el flujo de aire lo cual conduce    a un mayor flujo o una disminuci&oacute;n de la potencia del ventilador. Esos    atributos hacen de las superficies de minicanales y microcanales sean adecuados    medios para equipos de enfriamiento [7]. </font>     <P><font face="Verdana" size="2">Comparado con un intercambiador convencional,    la principal ventaja de un minintercambiador o de un microintercambiador es    su alta relaci&oacute;n &aacute;rea/volumen, lo cual da lugar a un alto coeficiente    global de traspaso de calor por unidad de volumen que puede ser mayor a 100    MW/m<sup>3</sup>K; mayor en 1 &oacute; 2 orden de magnitud que el de un intercambiador    convencional [8]. </font>      <P><font face="Verdana" size="2">De la literatura revisada se puede decir que    la teor&iacute;a para flujo monof&aacute;sico es aplicable tanto para canales    convencionales como para minicanales y microcanales [9]. Sin embargo, la teor&iacute;a    para flujo bif&aacute;sico en canales convencionales no es apropiada para minicanales    ni microcanales [10]. </font>     <P><font face="Verdana" size="2">Es objetivo de este trabajo hacer una revisi&oacute;n    bibliogr&aacute;fica de la caracter&iacute;stica de la transferencia de calor    durante la ebullici&oacute;n en minicanales y microcanales. Para ello se abordan    los t&eacute;rminos de minicanales y microcanales, ebullici&oacute;n en flujo    forzado y reg&iacute;menes (mapa) de flujo, entre otros. Adem&aacute;s se presenta    un resumen de las ecuaciones para la determinaci&oacute;n del coeficiente de    traspaso de calor en r&eacute;gimen bif&aacute;sico (h<sub>df</sub>) que han    sido obtenidas y publicadas por diferentes autores. </font>      <P>&nbsp;     <P><b><font face="Verdana" size="3">M&Eacute;TODOS Y MATERIALES</font></b>     <P><font face="Verdana" size="2"><b>Minicanal y microcanal</b> </font>     ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">&#191;Cu&aacute;ndo estamos en presencia de un    minicanal o microcanal? Los t&eacute;rminos minicanal y microcanal se emplean    en la literatura sin ning&uacute;n criterio universal a pesar de que muchos    trabajos se han realizado con el intento de buscar un criterio general para    estos t&eacute;rminos. Algunos investigadores definen el mismo criterio de transici&oacute;n,    entre macrocanal y minicanal/microcanal, tanto para flujo simple como para flujo    bif&aacute;sico en canales, mientras que otros definen el criterio independiente    para flujo de simple fase y para flujo bif&aacute;sico. </font>     <P>      <P><font face="Verdana" size="2">Mehendale [11] utiliz&oacute; la siguiente clasificaci&oacute;n    para definir los canales: </font>     <P><font face="Verdana" size="2">1&#956;m &#8804; D<sub>h</sub> &#8804; 100&#956;m:    Microcanal </font>      <P><font face="Verdana" size="2">100&#956;m &#8804; D<sub>h</sub> &#8804; 1 mm:    Minicanal </font>      <P><font face="Verdana" size="2">1 mm &#8804; D<sub>h</sub> &#8804; 6 mm: canal    compacto </font>      <P><font face="Verdana" size="2">6 mm &lt; D<sub>h</sub>: canal convencional </font>     <P><font face="Verdana" size="2">Por su parte Kandlikar y Balasubramanian [12]    emplean una clasificaci&oacute;n que se basa en el recorrido medio de las mol&eacute;culas    en flujo de simple fase, efectos de la tensi&oacute;n superficial y en la estructura    del flujo bif&aacute;sico. </font>     <P><font face="Verdana" size="2">Canal convencional: D<sub>h</sub> &#8805; 3 mm    </font>      <P><font face="Verdana" size="2">Minicanal: 200 &#181;m &#8804; D<sub>h</sub>    &lt; 3 mm </font>      ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">Microcanal:10 &#181;m &#8804; D<sub>h</sub> &lt;    200 &#181;m </font>      <P><font face="Verdana" size="2">Nanocanal o molecular: D<sub>h</sub> &#8804;    0.1 &#181;m </font>      <P><font face="Verdana" size="2">Basado en la observaci&oacute;n de que a medida    que las dimensiones del canal se hacen m&aacute;s peque&ntilde;as, la tensi&oacute;n    superficial se torna importante y por otro lado que el efecto de la gravedad    pierde su efecto, Kew y Cornwell [13] propusieron como criterio para definir    los macrocanales, minicanales y microcanales, el n&uacute;mero de confinamiento    (Co), dado por <a href="#e1">ecuaci&oacute;n 1</a></font>.     <P><a name="e1"></a><img src="/img/revistas/im/v17n2/e0105214.gif" width="173" height="76" alt="Ecuaci&oacute;n 1">      
<P>      <P>      <P><font face="Verdana" size="2">Donde &#963;, &#961;<sub>l</sub>, &#961;<sub>v</sub>,    g y D son la tensi&oacute;n superficial del l&iacute;quido, densidad del l&iacute;quido,    densidad del vapor, la gravedad y el di&aacute;metro del canal respectivamente.    </font>      <P><font face="Verdana" size="2">Este n&uacute;mero es la relaci&oacute;n entre    el tama&ntilde;o de la burbuja al momento de su desprendimiento de la superficie    y el di&aacute;metro del conducto. Este mismo criterio ha sido empleado por    Thome y colaboradores [14] y Barber [15]. Bajo este criterio, un canal cuyo    n&uacute;mero de confinamiento sea mayor que 0.5 se puede clasificar como minicanal/microcanal    y lo contrario ser&iacute;a un canal convencional. </font>     <P><font face="Verdana" size="2">Harirchian y Garimella [16] sugirieron el n&uacute;mero    convectivo de confinamiento como criterio para definir el macrocanal y el minicanal    o macrocanal, el cual viene dado por el n&uacute;mero Bond (Bo) y el n&uacute;mero    de Reynolds (Re) cuya expresi&oacute;n es: (<a href="#e2">ver ecuaci&oacute;n    2</a></font>)     <P><a name="e2"></a><img src="/img/revistas/im/v17n2/e0205214.gif" width="164" height="51" alt="Ecuaci&oacute;n 2">      
]]></body>
<body><![CDATA[<P>      <P>      <P><font face="Verdana" size="2">El n&uacute;mero Bond expresa la relaci&oacute;n    entre la fuerza de flotaci&oacute;n y la fuerza debida a la tensi&oacute;n (<a href="#e3">ver    ecuaci&oacute;n 3</a>)</font>      <P><a name="e3"></a><img src="/img/revistas/im/v17n2/e0305214.gif" width="169" height="66" alt="Ecuaci&oacute;n 3">      
<P>      <P>      <P><font face="Verdana" size="2">El n&uacute;mero de Reynolds expresa la relaci&oacute;n    entre la fuerza din&aacute;mica y la fuerza viscosa (<a href="#e4">ver ecuaci&oacute;n    4</a>)</font>      <P><a name="e4"></a><img src="/img/revistas/im/v17n2/e0405214.gif" width="111" height="38" alt="Ecuaci&oacute;n 4">      
<P>      <P><font face="Verdana" size="2">Para un valor menor que 160 el canal es catalogado    minicanal o microcanal y por encima de este valor es macrocanal. Con este criterio    los autores intentaron tener en cuenta los efectos de la densidad de flujo m&aacute;sico    y la viscosidad sobre el confinamiento del flujo en minicanales y microcanales    junto a la tensi&oacute;n superficial, la gravedad y la densidad. </font>     ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">Brauner [17] en su an&aacute;lisis propuso el    n&uacute;mero de E&#246;tv&#246;s (Eo) como criterio para considerar o no la    influencia de la tensi&oacute;n superficial y la gravedad. El valor discriminante    es Eo &lt; (2&#960;)2. (<a href="#e5">ver ecuaci&oacute;n 5</a>)</font>      <P><a name="e5"></a><img src="/img/revistas/im/v17n2/e0505214.gif" width="146" height="45" alt="Ecuaci&oacute;n 5">      
<P>      <P><font face="Verdana" size="2">Por su parte Lee [18] considerando la relaci&oacute;n    entre la fuerza de arrastre sobre la burbuja y la fuerza debido a la tensi&oacute;n    superficial, plantea como criterio de transici&oacute;n el siguiente: (<a href="#e6">ver    ecuaci&oacute;n 6</a>)</font>      <P><a name="e6"></a><img src="/img/revistas/im/v17n2/e0605214.gif" width="195" height="48" alt="Ecuaci&oacute;n 6">      
<P>     <P><font face="Verdana" size="2">De todo lo expuesto se puede decir que no existe    una unidad de criterios para la definici&oacute;n de minicanal y microcanal.    </font>     <P><font face="Verdana" size="2"><b>Ebullici&oacute;n en flujo forzado</b> </font>      <P><font face="Verdana" size="2">En la ebullici&oacute;n en flujo forzado es com&uacute;n    considerar que el calor se transfiere por dos mecanismos: convecci&oacute;n    forzada y ebullici&oacute;n nucleada. En la convecci&oacute;n forzada el calor    se transfiere de igual manera que en la convecci&oacute;n sin cambio de fase,    donde el calor transferido incrementa con el incremento de la densidad de flujo    m&aacute;sico (G). Este mecanismo se modela con ecuaciones similares a las de    convecci&oacute;n sin cambio de fase incluy&eacute;ndole un factor de mejoramiento    del flujo de fluido [13, 19]. En la ebullici&oacute;n nucleada el calor se transfiere    por medio de burbujas que surgen sobre la superficie de calentamiento. Estas    burbujas crecen y finalmente se separan de la superficie de calentamiento. Este    mecanismo es similar al de ebullici&oacute;n en volumen grande y se modela con    las ecuaciones de este &uacute;ltimo. Aqu&iacute; el coeficiente de traspaso    de calor incrementa con el incremento de la densidad de flujo de calor y es    independiente de la calidad del vapor y del flujo m&aacute;sico [20, 21]. </font>      <P><font face="Verdana" size="2">La transferencia de calor en el r&eacute;gimen    de ebullici&oacute;n nucleada se caracteriza por la formaci&oacute;n de burbujas,    lo cual es influenciada por la densidad de centros de nucleaci&oacute;n, el    di&aacute;metro de desprendimiento de la burbuja y la frecuencia de formaci&oacute;n    de &eacute;stas. </font>     ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">La densidad de centros de nucleaci&oacute;n (Na)    es la cantidad de cavidades o sitios en las cuales se generan las burbujas por    unidad de &aacute;rea del canal y da una medida de la energ&iacute;a que se    transfiere con la burbuja. Esta densidad de centros de nucleaci&oacute;n depende    de la densidad de flujo de calor (q<sup>&quot;</sup><sub>w</sub>) [22, 23],    velocidad del vapor [24], tama&ntilde;o de la cavidad [25] y tipo de fluido.    </font>      <P><font face="Verdana" size="2">La expresi&oacute;n obtenida por Kuo [26] se    basa fundamentalmente en la densidad de flujo de calor (<a href="#e7">ver ecuaci&oacute;n    7</a>)</font>      <P><a name="e7"></a><img src="/img/revistas/im/v17n2/e0705214.gif" width="135" height="37" alt="Ecuaci&oacute;n 7">      
<P>      <P><font face="Verdana" size="2">El ciclo de ebullici&oacute;n es el proceso de    calentamiento del l&iacute;quido, formaci&oacute;n, crecimiento y desprendimiento    de la burbuja. La cantidad de burbujas formadas por unidad de tiempo o frecuencia    de formaci&oacute;n de la burbuja (f) y el di&aacute;metro de desprendimiento    de la burbuja (Ddb) son factores que tienen gran influencia en la transferencia    de calor [9]. Durante la ebullici&oacute;n en flujo forzado la frecuencia de    formaci&oacute;n de la burbuja depende de la densidad de flujo de calor, de    la densidad de flujo m&aacute;sico, tipo de fluido, tama&ntilde;o y naturaleza    del centro de nucleaci&oacute;n (cavidad) y del di&aacute;metro de desprendimiento    de la burbuja. De forma general la frecuencia de desprendimiento de la burbuja    se eval&uacute;a a trav&eacute;s de una expresi&oacute;n de la forma [26,28]:    (<a href="#e8">ver ecuaciones 8</a> y <a href="#e9">9</a>) </font>      <P><a name="e8"></a><img src="/img/revistas/im/v17n2/e0805214.gif" width="171" height="32" alt="Ecuaci&oacute;n 8">      
<P>      <P><font face="Verdana" size="2">&oacute; </font>     <P><a name="e9"></a><img src="/img/revistas/im/v17n2/e0905214.gif" width="113" height="29" alt="Ecuaci&oacute;n 9">      
<P>      ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">Donde Ja es el criterio de Jakov el cual expresa    la relaci&oacute;n entre el calor sensible necesario para calentar una masa    de l&iacute;quido hasta su temperatura de saturaci&oacute;n (T<sub>sat</sub>)    y el calor latente (h<sub>lv</sub>) para evaporar la misma masa de l&iacute;quido.    (<a href="#e10">ver ecuaci&oacute;n 10</a>) </font>      <P><a name="e10"></a><img src="/img/revistas/im/v17n2/e1005214.gif" width="153" height="49" alt="Ecuaci&oacute;n 10">      
<P>      <P><font face="Verdana" size="2">El valor obtenido por Kuo [26], para un error    absoluto medio de 17 %, fue: (<a href="#e11">ver ecuaci&oacute;n 11</a>)</font>      <P><a name="e11"></a><img src="/img/revistas/im/v17n2/e1105214.gif" width="185" height="48" alt="Ecuaci&oacute;n 11">      
<P>      <P><font face="Verdana" size="2">En [29] los autores propusieron la frecuencia    de nucleaci&oacute;n adimensional en funci&oacute;n de la diferencia de temperatura    adimensional a trav&eacute;s de la expresi&oacute;n: (<a href="#e12">ver ecuaci&oacute;n    12</a>)</font>      <P><a name="e12"></a><img src="/img/revistas/im/v17n2/e1205214.gif" width="209" height="43" alt="Ecuaci&oacute;n 12">      
<P>      <P><font face="Verdana" size="2">Donde la frecuencia y la temperatura adimensional    fueron definidas como: (<a href="#e13">ver ecuaciones 13</a> y <a href="#e14">14</a>)</font>      ]]></body>
<body><![CDATA[<P><a name="e13"></a><img src="/img/revistas/im/v17n2/e1305214.gif" width="121" height="41" alt="Ecuaci&oacute;n  13">      
<P>      <P><font face="Verdana" size="2">y </font>     <P><a name="e14"></a><img src="/img/revistas/im/v17n2/e1405214.gif" width="165" height="44" alt="Ecuaci&oacute;n  14">      
<P>     <P><font face="Verdana" size="2">Donde W, &#181;<sub>l</sub>, k<sub>l</sub>, T<sub>s</sub>,    y T<sub>&#8734;</sub> son el ancho del canal, la viscosidad din&aacute;mica    y conductividad t&eacute;rmica del l&iacute;quido, la temperatura de la superficie    donde ebulle el l&iacute;quido y la temperatura del l&iacute;quido. </font>      <P><font face="Verdana" size="2">Aplicando un an&aacute;lisis dimensional, en    [29] obtuvieron una relaci&oacute;n entre el tama&ntilde;o al cual se desprende    la burbuja y el criterio de Reynolds; la cual expresa la disminuci&oacute;n    en forma exponencial del tama&ntilde;o de la burbuja al momento de su desprendimiento    (V<sub>db</sub>) a medida que incrementa el criterio de Reynolds (Re), o sea:    (<a href="#e15">ver ecuaci&oacute;n 15</a>) </font>      <P><a name="e15"></a><img src="/img/revistas/im/v17n2/e1505214.gif" width="205" height="39" alt="Ecuaci&oacute;n 15">      
<P>      <P><font face="Verdana" size="2">Donde H es la dimensi&oacute;n caracter&iacute;stica    del canal. </font>      ]]></body>
<body><![CDATA[<P>      <P>      <P><b><font face="Verdana" size="2">Mapa de reg&iacute;menes de flujo</font></b><font face="Verdana" size="2">    </font>      <P><font face="Verdana" size="2">La determinaci&oacute;n de los distintos reg&iacute;menes    de flujo ha sido motivo de estudio de diversos investigadores [16, 30, 31],    ya que, una vez conocido el r&eacute;gimen, se facilita el desarrollo de modelos    para el c&aacute;lculo, tanto del coeficiente de traspaso de calor como de la    ca&iacute;da de presi&oacute;n. </font>     <P><font face="Verdana" size="2">En minicanales y microcanales el r&eacute;gimen    de flujo depende de la interacci&oacute;n entre las fuerzas debido a la tensi&oacute;n    superficial y la de inercia. La tensi&oacute;n superficial es dominante en los    reg&iacute;menes de flujo de burbuja y bala; y la de inercia es dominante en    los reg&iacute;menes de flujo anular y remolino. La <a href="#f1">figura 1</a>    muestra una representaci&oacute;n de cada uno de estos tipos de flujos. </font>     <P align="center"><a name="f1"></a><img src="/img/revistas/im/v17n2/f0105214.gif" width="463" height="318" alt="Fig. 1. Reg&iacute;menes de flujo">      
<P>     <P><font face="Verdana" size="2">El mapa de reg&iacute;menes de flujo propuesto    por Harirchian y Garimella [16, 31] plantea que para valores de Bo0.5Re&lt;160    se observa confinamiento del vapor tanto en los reg&iacute;menes de flujo bala    y remolino/anular, mientras que para Bo0.5Re&gt;160 no se observa confinamiento.    Para baja densidad de flujo de calor con Bl&lt;0.017(Bo0.4Re-0.3) y Bo0.5Re&lt;160    se observa flujo bala y con Bo0.5Re&gt;160 se observa flujo en burbuja. Para    alta densidad de flujo de calor o sea, para Bl&gt;0.017(Bo0.4Re-0.3) las burbujas    coalescen y dan lugar a un flujo remolino/anular. Bl y Bo son los n&uacute;meros    de ebullici&oacute;n y bond respectivamente, definidos como: (<a href="#e16">ver    ecuaciones 16</a> y <a href="#e17">17</a>)</font>      <P><a name="e16"></a><img src="/img/revistas/im/v17n2/e1605214.gif" width="128" height="55" alt="Ecuaci&oacute;n 16">      
<P>     ]]></body>
<body><![CDATA[<P><a name="e17"></a><img src="/img/revistas/im/v17n2/e1705214.gif" width="165" height="44" alt="Ecuaci&oacute;n  17">      
<P>      <P><font face="Verdana" size="2">En [16] los autores proponen como longitud a    la cual ocurre la transici&oacute;n de r&eacute;gimen de burbuja a flujo anular    la siguiente: (<a href="#e18">ver ecuaci&oacute;n 18</a>)</font>      <P><a name="e18"></a><img src="/img/revistas/im/v17n2/e1805214.gif" width="280" height="45" alt="Ecuaci&oacute;n  18">      
<P>      <P><font face="Verdana" size="2">Donde A<sub>cs</sub> y P<sub>H</sub> son el &aacute;rea    de la secci&oacute;n transversal del canal y el per&iacute;metro h&uacute;medo    del mismo respectivamente. </font>      <P><font face="Verdana" size="2">Revellin and Thome [32] propusieron un mapa de    reg&iacute;menes de flujo a partir de datos obtenidos para ebullici&oacute;n    de refrigerante R134a y R245fa en tubos circulares. En su trabajo distinguieron    tres tipos de reg&iacute;menes: de burbujas aisladas, de burbujas coalesadas    y anular. Las condiciones geom&eacute;tricas y de flujo empleadas fueron: conductos    de 0.509 y 0.790 mm, longitud de calentamiento de 20 a 70 mm, densidad de flujo    m&aacute;sico de 210 a 2094 kg/m<sup>2</sup>s, densidad de flujo de calor de    3.1 a 597 kW/m<sup>2</sup>, temperatura de saturaci&oacute;n de 26, 30 y 35    &#186;C y subenfriamiento de 2 hasta 15 &#186;C. La transici&oacute;n entre    el r&eacute;gimen de burbujas aisladas a burbujas coalesadas se cumple cuando:    (<a href="#e19">ver ecuaci&oacute;n 19</a>) </font>      <P><a name="e19"></a><img src="/img/revistas/im/v17n2/e1905214.gif" width="204" height="50" alt="Ecuaci&oacute;n  19">      
<P>      <P>      ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">Para la transici&oacute;n del r&eacute;gimen    de burbujas coalesadas al anular se toma el criterio: (<a href="#e20">ver ecuaci&oacute;n    20</a>)</font>      <P><a name="e20"></a><img src="/img/revistas/im/v17n2/e2005214.gif" width="228" height="40" alt="Ecuaci&oacute;n   20">      
<P>      <P><font face="Verdana" size="2">Donde We es el n&uacute;mero de Weber (<a href="#e21">ver    ecuaci&oacute;n 21</a>)</font>      <P><a name="e21"></a><img src="/img/revistas/im/v17n2/e2105214.gif" width="113" height="46" alt="Ecuaci&oacute;n   21">      
<P>      <P><font face="Verdana" size="2">De los reg&iacute;menes de flujo que aparecen    en minicanales y microcanales, se puede concluir que son similares a los que    aparecen en canales convencionales: burbuja, bala, remolino y anular. </font>      <P><font face="Verdana" size="2"><b>Ecuaciones empleadas para la determinaci&oacute;n    del coeficiente de traspaso de calor en minicanales y microcanales </b></font>      <P><font face="Verdana" size="2">Para el c&aacute;lculo de la transferencia de    calor durante la ebullici&oacute;n en flujo forzado en conductos, las correlaciones    que se emplean se pueden dividir en dos grupos: </font> <ul>       <li><font face="Verdana" size="2">Correlaciones que dan un coeficiente de traspaso      de calor promedio para todo el proceso de ebullici&oacute;n. </font> </li>       ]]></body>
<body><![CDATA[<li><font face="Verdana" size="2">Correlaciones que dan un coeficiente de traspaso      de calor local en funci&oacute;n de la calidad del vapor. </font> </li>     </ul>     <P><font face="Verdana" size="2">El grupo de las correlaciones para el coeficiente    de traspaso de calor local puede dividirse en: </font> <ul>       <li><font face="Verdana" size="2">Modelo mejorado </font> </li>       <li><font face="Verdana" size="2"> Modelo de superposici&oacute;n </font> </li>       <li><font face="Verdana" size="2">Modelo asint&oacute;tico </font> </li>     </ul>     <P><font face="Verdana" size="2">En el modelo mejorado el coeficiente de traspaso    de calor para flujo bif&aacute;sico (h<sub>df</sub>) se calcula como mismo se    halla el monof&aacute;sico, considerando todo el fluido como l&iacute;quido    (h<sub>L</sub>) y se afecta por un factor que tiene en cuenta la influencia    de la presencia de las dos fases (E). (<a href="#e22">ver ecuaci&oacute;n 22</a>)</font>      <P><a name="e22"></a><img src="/img/revistas/im/v17n2/e2205214.gif" width="122" height="31" alt="Ecuaci&oacute;n   22">      
<P>      ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">El coeficiente de traspaso de calor para una    sola fase h<sub>L</sub> se calcula por las ecuaciones de Gnielinski, citado    por [21] </font>      <P><font face="Verdana" size="2">El modelo de superposici&oacute;n supone que    el coeficiente de traspaso de calor bif&aacute;sico es la suma de la componente    convectiva monof&aacute;sica (h<sub>sf</sub>) y la de ebullici&oacute;n nucleada    (h<sub>en</sub>), o sea: (<a href="#e23">ver ecuaci&oacute;n 23</a>)</font>      <P>      <P><a name="e23"></a><img src="/img/revistas/im/v17n2/e2305214.gif" width="134" height="30" alt="Ecuaci&oacute;n   23">      
<P><font face="Verdana" size="2">El modelo asint&oacute;tico es similar al de    superposici&oacute;n pero en forma potencial, o sea: (<a href="#e24">ver ecuaci&oacute;n    24</a>)</font>      <P><a name="e24"></a><img src="/img/revistas/im/v17n2/e2405214.gif" width="130" height="30" alt="Ecuaci&oacute;n  24">      
<P>     <P><font face="Verdana" size="2">De forma general estos modelos pueden resumirse    de la forma [33,34]: (<a href="#e25">ver ecuaci&oacute;n 25</a>)</font>      <P><a name="e25"></a><img src="/img/revistas/im/v17n2/e2505214.gif" width="224" height="36" alt="Ecuaci&oacute;n   25">      
<P>      ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">Aqu&iacute;, la contribuci&oacute;n de ambas    partes es intensificada y/o inhibida por el factor intensificador E o por el    factor de inhibici&oacute;n S. El exponente n tiene en cuenta la transici&oacute;n    de un mecanismo a otro. Dependiendo del valor de n el modelo de superposici&oacute;n    puede subdividirse en: Lineal (n=1) [3536] y no lineal (n&#8800;1). Ejemplo de modelo    con n=2 es el de Liu [37] y con n=3 es el de Steiner [38]. </font>     <P><font face="Verdana" size="2">Los modelos basados en la estructura del flujo    se basan en el m&eacute;todo de superposici&oacute;n y toman en cuenta las caracter&iacute;sticas    de la estructura del flujo: (<a href="#e26">ver ecuaci&oacute;n 26</a>)</font>      <P><a name="e26"></a><img src="/img/revistas/im/v17n2/e2605214.gif" width="227" height="42" alt="Ecuaci&oacute;n   26">      
<P>      <P><font face="Verdana" size="2">Donde &#952;seco es el &aacute;ngulo del per&iacute;metro    seco, h<sub>V</sub> es el coeficiente de traspaso de calor de la fase vapor,    hh&uacute;m es el coeficiente de traspaso de calor del per&iacute;metro h&uacute;medo    que corresponde a una superposici&oacute;n no lineal de efectos tomando en consideraci&oacute;n    el espesor equivalente del l&iacute;quido </font>      <P><font face="Verdana" size="2"><b>Correlaciones emp&iacute;ricas</b> </font>      <P><font face="Verdana" size="2">Las correlaciones para la determinaci&oacute;n    del coeficiente de traspaso de calor en flujo bif&aacute;sico, de forma general,    se basan en coeficientes de traspaso de calor para fase l&iacute;quida h<sub>L</sub>    [33,39] y en criterios adimensionales, o sea: (<a href="#e27">ver ecuaci&oacute;n    27</a>)</font>      <P><a name="e27"></a><img src="/img/revistas/im/v17n2/e2705214.gif" width="254" height="38" alt="Ecuaci&oacute;n  27">      
<P>      <P><font face="Verdana" size="2">El error absoluto medio (EAM) de las correlaciones    se determina seg&uacute;n la <a href="#e28">expresi&oacute;n 28</a> [40, 41]:    </font>      ]]></body>
<body><![CDATA[<P><a name="e28"></a><img src="/img/revistas/im/v17n2/e2805214.gif" width="238" height="49" alt="Ecuaci&oacute;n   28">      
<P>      <P><font face="Verdana" size="2">Donde Np es la cantidad de puntos (datos) analizados    Y<sub>cal</sub>, es valor calculado y Y<sub>exp</sub> es el valor experimental.    </font>      <P><font face="Verdana" size="2">De las expresiones empleadas, la que presenta    menor error absoluto medio es la <a href="#e29">ecuaci&oacute;n 29</a> propuesta    por Basu [42]: </font>      <P><a name="e29"></a><img src="/img/revistas/im/v17n2/e2905214.gif" width="267" height="53" alt="Ecuaci&oacute;n   29">      
<P>     <P>&nbsp;     <P><font face="Verdana" size="2"><b><font size="3">CONCLUSIONES</font></b></font>     <P><font face="Verdana" size="2">Resulta necesario elaborar un criterio general    que est&eacute; basado en las propiedades termof&iacute;sicas de los fluidos    y en las condiciones de operaci&oacute;n para conocer las fronteras entre canal    convencional, minicanales y microcanales.</font>     <P><font face="Verdana" size="2">El producto de la frecuencia y di&aacute;metro    de desprendimiento de la burbuja es un orden de magnitud menor en minicanales    y microcanales respecto a canales convencionales. </font>      ]]></body>
<body><![CDATA[<P><font face="Verdana" size="2">La estructura del flujo en ebullici&oacute;n    en minicanales y micronales es similar al de canales convencionales: flujo en    burbuja, flujo bala y flujo anular. </font>      <P><font face="Verdana" size="2">Para la determinaci&oacute;n del coeficiente    de traspaso de calor bif&aacute;sico la expresi&oacute;n de Basu, <a href="#e29">ecuaci&oacute;n    29</a>, es la que presenta el menor error absoluto medio. </font>      <P>&nbsp;     <P><font face="Verdana" size="3"><b>REFERENCIAS</b></font>      <!-- ref --><P><font face="Verdana" size="2">1. Tuckerman, D. B. y Pease, R. F. W. &quot;High    performance heat sinking for VLSI&quot;. <i>IEEE Electron. Device Lett</i>.    EDL2. 1982, p. 126-129. ISSN 0741-3106. </font>    <!-- ref --><P><font face="Verdana" size="2">2. Kandlikar, S. G. &quot;Nucleation characteristics    and stability considerations during flow boiling in microchannels&quot;. <i>Experimental    Thermal and Fluid Science</i>. 2006, vol. 30, p. 441-447. ISSN 0894-1777. DOI    10.1016/j.expthermflusci.2005.10.001</font>    <!-- ref --><P><font face="Verdana" size="2">3. Mudawar, I. &quot;Assessment of high-heat-flux    thermal management schemes&quot;. <i>IEEE Transactions on Components and Packaging    Technologies</i>. 2001, vol. 24, n&ordm;. 2, p. 122-141. ISSN 1521-3331. </font>    <!-- ref --><P><font face="Verdana" size="2">4. Thome, J. R. &quot;Boiling in microchannels:    A review of experiment and theory&quot;. <i>International Journal of Heat and    Fluid Flow</i>. 2004, vol. 25, n&ordm;. 2, p. 128-139. ISSN 0142-727X. DOI 0.1016/j.ijheatfluidflow.2003.11.005</font>    <!-- ref --><P><font face="Verdana" size="2">5. Shah, R. K. y Sekulic, D. P. <i>Fundamental    of Heat Exchanger Design</i>. New Jersey, USA: John Wiley &amp; Sons, INC.,    2003. Vol. 1, p. 9. ISBN 0-471-32171-0.</font>    <!-- ref --><P><font face="Verdana" size="2">6. Kaew-On, J. y Sakamatapan, K. &quot;Flow boiling    heat transfer of R134a in the multiport minichannel heat exchangers&quot;. <i>Experimental    Thermal and Fluid Science</i>. 2011, vol. 35, n&ordm;. 2, p. 364-374. ISSN 0894-1777.    </font>    <!-- ref --><P><font face="Verdana" size="2">7. Kandlikar, S. G. &quot;A Roadmap for Implementing    Minichannels in Refrigeration and Air-Conditioning Systems-Current Status and    Future Directions&quot;. <i>Heat Transfer Engineering</i>. 2007, vol. 28, n&ordm;.    12, p. 973-985. ISSN 0145-7632. DOI 10.1080/01457630701483497</font>    <!-- ref --><P><font face="Verdana" size="2">8. Jiang, P. X. y Ming Hong, F. &quot;Thermal-hydraulic    performance of small scale micro-channel and porous-media heat-exchangers&quot;.    <i>International Journal of Heat and Mass Transfer.</i> 2001, vol. 44, p. 1039-1051.    ISSN 0017-9310.</font>    <!-- ref --><P><font face="Verdana" size="2">9. Okawa, T. &quot;Onset Of Nucleate Boiling    In Mini And Micochannels: A Brief Review&quot;. <i>Frontiers in Heat and Mass    Transfer</i>. 2012, vol. 3, p. 1-8. ISSN 2151-8629. DOI 10.5098/hmt.v3.1.3001</font>    <!-- ref --><P><font face="Verdana" size="2">10. Kandlikar, S. G. &quot;Similarities and Differences    Between Flow Boiling in Microchannels and Pool Boiling&quot;. <i>Heat Transfer    Engineering</i>. 2010, vol. 31, n&ordm;. 3, p. 159-167. ISSN 0145-7632. DOI    10.1080/01457630903304335</font>    <!-- ref --><P><font face="Verdana" size="2">11. Mehendale, S. S. y Jacobi, A. M. &quot;Fluid    Flow and Heat Transfer at Micro-and Meso-Scales with Application to Heat Exchanger    Design&quot;. <i>Applied Mechanics Reviews</i>. 2000, vol. 53, n&ordm;. 7, p.    175-193. ISSN 0003-6900.</font>    <!-- ref --><P><font face="Verdana" size="2">12. Kandlikar, S. G. y Balasubramanian, P. &quot;An    Extension of the Flow Boiling Correlation to Transition, Laminar, and Deep Laminar    Flows in Minichannels and Microchannels&quot;. <i>Heat Transfer Engineering</i>.    2004, vol. 25, n&ordm;. 3, p. 89-93. ISSN 0145-7632. DOI 10.1080/01457630490280425</font>    <!-- ref --><P><font face="Verdana" size="2">13. Kew, P. A. y Cornwell, K. &quot;Correlations    for the Prediction of Boiling Heat Transfer in Small-Diameter Channels&quot;.    <i>Applied Thermal Engineering</i>. 1997, vol. 17, n&ordm;. 8-10, p. 705-715.    ISSN 1359-4311.</font>    <!-- ref --><P><font face="Verdana" size="2">14. Thome, J. R. y Dupont, V. &quot;Heat Transfer    Model for Evaporation in Microchannels. Part I: Presentation of the Model&quot;.    <i>International Journal of Heat and Mass Transfer</i>. 2004, vol. 47, n&ordm;.    14-16, p. 3375-3385. ISSN 0017-9310. </font>    <!-- ref --><P><font face="Verdana" size="2">15. Barber, J. y Brutin, D. &quot;Bubble confinement    in flow boiling of FC-72 in a &quot;rectangular&quot; microchannel of high aspect    ratio&quot;. <i>Experimental Thermal and Fluid Science</i>. 2010, vol. 34, n&ordm;.    8, p. 1375-1388. ISSN 0894-1777.</font>    <!-- ref --><P><font face="Verdana" size="2">16. Harirchian, T. y Garimella, S. V. &quot;Flow    Regime-Based Modeling of Heat Transfer and Pressure Drop in Microchannel Flow    Boiling&quot;. <i>International Journal of Heat and Mass Transfer</i>. 2012,    vol. 55, p. 1246-1260. ISSN 0017-9310. DOI 10.1016/j.ijheatmasstransfer.2011.09.024.</font>    <!-- ref --><P><font face="Verdana" size="2">17. Brauner, N. y Maron, D. M. &quot;Identification    of the Range of Small Diameters, Conduits, Regarding Two-Phase Flow Pattern    Transitions&quot;. <i>International Communications in Heat and Mass Transfer</i>.    1992, vol. 19, n&ordm;. 1, p. 29-39. ISSN 0017-9310.</font>    <!-- ref --><P><font face="Verdana" size="2">18. Lee, J. y Mudawar, I. &quot;Critical heat    flux for subcooled flow boiling in microchannel heat sinks&quot;. <i>Int. J.    Heat Mass Transfer</i>. 2009, vol. 52, p. 3341-3352. ISSN 0017-9310.</font>    <!-- ref --><P><font face="Verdana" size="2">19. Zhang, W. y Hibiki, T. &quot;Correlation    for flow boiling heat transfer at low liquid reynolds number in small diameter    channels&quot;. <i>J. Heat Transfer</i>. 2005, vol. 127, p. 1214-1221. ISSN    0022-1481. </font>    <!-- ref --><P><font face="Verdana" size="2">20. Tibiri&ccedil;&aacute;, C. B. y Ribatski,    G. &quot;Flow Boiling Heat Transfer of R134a and R245fa in a 2.3 mm Tube&quot;.    <i>Int. J. Heat Mass Transfer</i>. 2010, vol. 53, p. 2459-2468. ISSN 0017-9310.</font>    <!-- ref --><P><font face="Verdana" size="2">21. Kandlikar, S. G. &quot;A Scale Analysis Based    Theoretical Force Balance Model for Critical Heat Flux (CHF) During Saturated    Flow Boiling in Microchannels and Minichannels&quot;. <i>Journal of Heat Transfer</i>.    2010, vol. 132, ISSN 0022-1481. DOI 10.1115/1.4001124</font>    <!-- ref --><P><font face="Verdana" size="2">22. Cooke, D. y Kandlikar, S. G. &quot;Pool Boiling    Heat Transfer and Bubble Dynamics Over Plain and Enhanced Microchannels&quot;.    <i>Journal of Heat Transfer</i>. 2011, vol. 133, p. 052902-052909. ISSN 0022-1481.    DOI 10.1115/1.4003046</font>    <!-- ref --><P><font face="Verdana" size="2">23. Liu, G. y Xu, J. &quot;Seed bubbles trigger    boiling heat transfer in silicon microchannels&quot;. <i>Microfluidics and Nanofluidics</i>.    2010, vol. 8, n&ordm;. 3, p. 341-359. ISSN 1613-4982. </font>    <!-- ref --><P><font face="Verdana" size="2">24. Thome, J. R. y Consolini, L. &quot;Mechanisms    of boiling in micro-channels critical assessment&quot;. <i>Heat Transfer Eng</i>.    2010, vol. 31, n&ordm;. 4, p. 288-297. ISSN 0145-7632. </font>    <!-- ref --><P><font face="Verdana" size="2">25. Zhuan, R. y Wang, W. &quot;Simulation on    nucleate boiling in micro-channel&quot;. <i>International Journal of Heat and    Mass Transfer</i>. 2010, vol. 53, n&ordm;. 1-3, p. 502-512. ISSN 0017-9310.    </font>    <!-- ref --><P><font face="Verdana" size="2">26. Kuo, C. J. y Kosar, A. &quot;Bubble Dynamics    During Boiling in Enhanced Surface Microchannels&quot;. <i>Journal of Microelectromechanical    Systems</i>. 2006, vol. 15, n&ordm;. 6, p. 1514-1527. ISSN 1057-7157. DOI 10.1109/JMEMS.2006.885975</font>    <!-- ref --><P><font face="Verdana" size="2">27. Fu, X. y Zhang, P. &quot;Bubble growth, departure    and the following flow pattern evolution during flow boiling in a mini-tube&quot;.<i>    International Journal of Heat and Mass Transfer</i>. 2010, vol. 53, n&ordm;.    21-22, p. 4819-4831. ISSN 0017-9310.</font>    <!-- ref --><P><font face="Verdana" size="2">28. Karayiannis, T. G. y Shiferaw, D. &quot;Flow    patterns and heat transfer for flow boiling in small to micro diameter tubes&quot;.    <i>Heat Transfer Eng</i>. 2010, vol. 31, p. 257-275. ISSN 0145-7632.</font>    <!-- ref --><P><font face="Verdana" size="2">29. Lee, M. y Cheung, L. S. L. &quot;Height effect    on nucleation-site activity and size-dependent bubble dynamics in microchannel    convective boiling&quot;. <i>Journal of Micromechanics and Microengineering</i>.    2005, vol. 15, p. 2121-2129. ISSN 0960-1317. DOI 10.1088/0960-1317/15/11/018</font>    <!-- ref --><P><font face="Verdana" size="2">30. Cheng, L. y Ribatski, G. &quot;New prediction    methods for CO2 evaporation inside tubes Part I - A two-phase flow pattern map    and a flow pattern based phenomenological model for two-phase flow frictional    pressure drops&quot;. <i>Int. J. Heat Mass Transfer</i>. 2008, vol. 51, p. 111-124.    ISSN 0017-9310. </font>    <!-- ref --><P><font face="Verdana" size="2">31. Harirchian, T. y Garimella, S. V. &quot;A    comprehensive flow regime map for microchannel flow boiling with quantitative    transition criteria&quot;. <i>International Journal of Heat and Mass Transfer</i>.    2010, vol. 53, p. 2694-2702. ISSN 0017-9310. DOI 10.1016/j.ijheatmasstransfer.2010.02.039</font>    <!-- ref --><P><font face="Verdana" size="2">32. Revellin, R. y Thome, J. R. &quot;A New Type    of Diabatic Flow Pattern Map for Boiling Heat Transfer in Microchannels&quot;.    <i>Journal of Micromechanics and Microengineering</i>. 2007, vol. 17, p. 788-796.    ISSN 0960-1317.</font>    <!-- ref --><P><font face="Verdana" size="2">33. Gnielinski, V. &quot;New Equations for Heat    and Mass Transfer in Turbulent Pipe and Channel Flow&quot;. <i>International    Chemical Engineering</i>. 1976, vol. 16, p. 359-368. ISSN 0020-6318. </font>    <!-- ref --><P><font face="Verdana" size="2">34. Bertsch, S. S. y Groll, E. A. &quot;A composite    heat transfer correlation for saturated flow boiling in small channels&quot;.    <i>Int. J. Heat and Mass Transfer</i>. 2009, vol. 52, p. 2110-2118. ISSN 0017-9310.</font>    <!-- ref --><P><font face="Verdana" size="2">35. Gungor, K. E. y Winterton, A. &quot;A general    correlation for flow boiling in tubes and annuli&quot;. <i>Int. J. of Heat and    Mass Transfer.</i> 1986, vol. 29, n&ordm;. 3, p. 351-358. ISSN 0017-9310. </font>    <!-- ref --><P><font face="Verdana" size="2">36. Jung, D. y Radermacher, R. &quot;Prediction    of evaporation heat transfer coefficient and pressure drop of refrigerant mixtures&quot;.    <i>Int. J. of Refrigeration</i>. 1993, vol. 16, n&ordm;. 5, p. 330-338. ISSN    0140-7007. </font>    <!-- ref --><P><font face="Verdana" size="2">37. Liu, Z. y Winterton, R. S. &quot;A general    correlation for saturated and subcooled flow boiling in tubes and annuli, based    on a nucleate pool boiling equation&quot;. <i>Int. J. of Heat and Mass Transfer</i>.    1991, vol. 34, n&ordm;. 11, p. 2759-2766. ISSN 0017-9310.</font>    <!-- ref --><P><font face="Verdana" size="2">38. Steiner, D. y Taborek, J. &quot;Flow Boiling    Heat Transfer in Vertical Tubes Correlated by an Asymptotic Model&quot;. <i>Heat    Transfer Engineering</i>. 1992, vol. 13, p. 43-68. ISSN 0022-1481.</font>    <!-- ref --><P><font face="Verdana" size="2">39. Shiferaw, D. y Karayiannis, T. G. &quot;Flow    boiling in a 1.1 mm tube with R134a experimental results and comparison with    model&quot;. <i>Int. J. Thermal Sciences</i>. 2009, vol. 48, p. 331-341. ISSN    1290-0729. </font>    <!-- ref --><P><font face="Verdana" size="2">40. Basu, S. y Ndao, S. &quot;Flow Boiling of    R134a in Circular Microtubes-Part II Study of Critical Heat Flux Condition&quot;.    <i>Journal of Heat Transfer</i>. 2011, vol. 133, p. 051503-051509. ISSN 0022-1481.    DOI 10.1115/1.4003160</font>    <!-- ref --><P><font face="Verdana" size="2">41. Xiande, F. y Rongrong, S. &quot;Correlations    of Flow Boiling Heat Transfer of R-134a in Minichannels comparative study&quot;.    <i>Energy Science and Technology</i>. 2011, vol. 1, n&ordm;. 1, p. 1-15. ISSN    1923-8460.</font>    <!-- ref --><P><font face="Verdana" size="2">42. Basu, S. y Ndao, S. &quot;Flow Boiling of    R134a in Circular Microtubes-Part I Study of Heat Transfer Characteristics&quot;.    <i>Journal of Heat Transfer</i>. 2011, vol. 133. ISSN 0022-1481. DOI 10.1115/1.4003159</font>    <P>&nbsp;     <P>&nbsp;     <P><font face="Verdana" size="2">Recibido: 27 de enero de 2014.    <br>   Aceptado: 27 de marzo de 2014. </font>      ]]></body>
<body><![CDATA[<P>&nbsp;     <P>&nbsp;     <P><font face="Verdana" size="2"><i>C&eacute;sar-Arnaldo Cisneros-Ram&iacute;rez.</i>    Instituto Superior Polit&eacute;cnico Jos&eacute; Antonio Echeverr&iacute;a,    Centro de Estudios de Tecnolog&iacute;as Energ&eacute;ticas Renovables, CETER,    La Habana, Cuba.    <br>   </font><font face="Verdana" size="2">Correo electr&oacute;nico: <a href="mailto:cesar@ceter.cujae.edu.cu">cesar@ceter.cujae.edu.cu</a></font>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tuckerman]]></surname>
<given-names><![CDATA[D. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Pease]]></surname>
<given-names><![CDATA[R. F. W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[High performance heat sinking for VLSI]]></article-title>
<source><![CDATA[IEEE Electron. Device Lett. EDL2]]></source>
<year>1982</year>
<page-range>126-129</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kandlikar]]></surname>
<given-names><![CDATA[S. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Nucleation characteristics and stability considerations during flow boiling in microchannels]]></article-title>
<source><![CDATA[Experimental Thermal and Fluid Science]]></source>
<year>2006</year>
<volume>30</volume>
<page-range>441-447</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mudawar]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Assessment of high-heat-flux thermal management schemes]]></article-title>
<source><![CDATA[IEEE Transactions on Components and Packaging Technologies]]></source>
<year>2001</year>
<volume>24</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>122-141</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thome]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Boiling in microchannels: A review of experiment and theory]]></article-title>
<source><![CDATA[International Journal of Heat and Fluid Flow]]></source>
<year>2004</year>
<volume>25</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>128-139</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[R. K.]]></given-names>
</name>
<name>
<surname><![CDATA[Sekulic]]></surname>
<given-names><![CDATA[D. P.]]></given-names>
</name>
</person-group>
<source><![CDATA[Fundamental of Heat Exchanger Design]]></source>
<year>2003</year>
<volume>1</volume>
<page-range>9</page-range><publisher-loc><![CDATA[New Jersey ]]></publisher-loc>
<publisher-name><![CDATA[John Wiley & Sons, INC.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kaew-On]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Sakamatapan]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow boiling heat transfer of R134a in the multiport minichannel heat exchangers]]></article-title>
<source><![CDATA[Experimental Thermal and Fluid Science]]></source>
<year>2011</year>
<volume>35</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>364-374</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kandlikar]]></surname>
<given-names><![CDATA[S. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Roadmap for Implementing Minichannels in Refrigeration and Air-Conditioning Systems-Current Status and Future Directions]]></article-title>
<source><![CDATA[Heat Transfer Engineering]]></source>
<year>2007</year>
<volume>28</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>973-985</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jiang]]></surname>
<given-names><![CDATA[P. X.]]></given-names>
</name>
<name>
<surname><![CDATA[Ming Hong]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thermal-hydraulic performance of small scale micro-channel and porous-media heat-exchangers]]></article-title>
<source><![CDATA[International Journal of Heat and Mass Transfer]]></source>
<year>2001</year>
<volume>44</volume>
<page-range>1039-1051</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Okawa]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Onset Of Nucleate Boiling In Mini And Micochannels: A Brief Review]]></article-title>
<source><![CDATA[Frontiers in Heat and Mass Transfer]]></source>
<year>2012</year>
<volume>3</volume>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kandlikar]]></surname>
<given-names><![CDATA[S. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Similarities and Differences Between Flow Boiling in Microchannels and Pool Boiling]]></article-title>
<source><![CDATA[Heat Transfer Engineering]]></source>
<year>2010</year>
<volume>31</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>159-167</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mehendale]]></surname>
<given-names><![CDATA[S. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Jacobi]]></surname>
<given-names><![CDATA[A. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fluid Flow and Heat Transfer at Micro-and Meso-Scales with Application to Heat Exchanger Design]]></article-title>
<source><![CDATA[Applied Mechanics Reviews]]></source>
<year>2000</year>
<volume>53</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>175-193</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kandlikar]]></surname>
<given-names><![CDATA[S. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Balasubramanian]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An Extension of the Flow Boiling Correlation to Transition, Laminar, and Deep Laminar Flows in Minichannels and Microchannels]]></article-title>
<source><![CDATA[Heat Transfer Engineering]]></source>
<year>2004</year>
<volume>25</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>89-93</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kew]]></surname>
<given-names><![CDATA[P. A.]]></given-names>
</name>
<name>
<surname><![CDATA[Cornwell]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correlations for the Prediction of Boiling Heat Transfer in Small-Diameter Channels]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>1997</year>
<volume>17</volume>
<numero>8-10</numero>
<issue>8-10</issue>
<page-range>705-715</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thome]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Dupont]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Heat Transfer Model for Evaporation in Microchannels. Part I: Presentation of the Model]]></article-title>
<source><![CDATA[International Journal of Heat and Mass Transfer]]></source>
<year>2004</year>
<volume>47</volume>
<numero>14-16</numero>
<issue>14-16</issue>
<page-range>3375-3385</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Barber]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Brutin]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bubble confinement in flow boiling of FC-72 in a "rectangular" microchannel of high aspect ratio]]></article-title>
<source><![CDATA[Experimental Thermal and Fluid Science]]></source>
<year>2010</year>
<volume>34</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1375-1388</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Harirchian]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Garimella]]></surname>
<given-names><![CDATA[S. V.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow Regime-Based Modeling of Heat Transfer and Pressure Drop in Microchannel Flow Boiling]]></article-title>
<source><![CDATA[International Journal of Heat and Mass Transfer]]></source>
<year>2012</year>
<volume>55</volume>
<page-range>1246-1260</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Brauner]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Maron]]></surname>
<given-names><![CDATA[D. M.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Identification of the Range of Small Diameters, Conduits, Regarding Two-Phase Flow Pattern Transitions]]></article-title>
<source><![CDATA[International Communications in Heat and Mass Transfer]]></source>
<year>1992</year>
<volume>19</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>29-39</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Mudawar]]></surname>
<given-names><![CDATA[I.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Critical heat flux for subcooled flow boiling in microchannel heat sinks]]></article-title>
<source><![CDATA[Int. J. Heat Mass Transfer]]></source>
<year>2009</year>
<volume>52</volume>
<page-range>3341-3352</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
<name>
<surname><![CDATA[Hibiki]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correlation for flow boiling heat transfer at low liquid reynolds number in small diameter channels]]></article-title>
<source><![CDATA[J. Heat Transfer]]></source>
<year>2005</year>
<volume>127</volume>
<page-range>1214-1221</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tibiriçá]]></surname>
<given-names><![CDATA[C. B.]]></given-names>
</name>
<name>
<surname><![CDATA[Ribatski]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow Boiling Heat Transfer of R134a and R245fa in a 2.3 mm Tube]]></article-title>
<source><![CDATA[Int. J. Heat Mass Transfer]]></source>
<year>2010</year>
<volume>53</volume>
<page-range>2459-2468</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kandlikar]]></surname>
<given-names><![CDATA[S. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A Scale Analysis Based Theoretical Force Balance Model for Critical Heat Flux (CHF) During Saturated Flow Boiling in Microchannels and Minichannels]]></article-title>
<source><![CDATA[Journal of Heat Transfer]]></source>
<year>2010</year>
<volume>132</volume>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cooke]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Kandlikar]]></surname>
<given-names><![CDATA[S. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Pool Boiling Heat Transfer and Bubble Dynamics Over Plain and Enhanced Microchannels]]></article-title>
<source><![CDATA[Journal of Heat Transfer]]></source>
<year>2011</year>
<volume>133</volume>
<page-range>052902-052909</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
<name>
<surname><![CDATA[Xu]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Seed bubbles trigger boiling heat transfer in silicon microchannels]]></article-title>
<source><![CDATA[Microfluidics and Nanofluidics]]></source>
<year>2010</year>
<volume>8</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>341-359</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Thome]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
<name>
<surname><![CDATA[Consolini]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Mechanisms of boiling in micro-channels critical assessment]]></article-title>
<source><![CDATA[Heat Transfer Eng]]></source>
<year>2010</year>
<volume>31</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>288-297</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhuan]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[W.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Simulation on nucleate boiling in micro-channel]]></article-title>
<source><![CDATA[International Journal of Heat and Mass Transfer]]></source>
<year>2010</year>
<volume>53</volume>
<numero>1-3</numero>
<issue>1-3</issue>
<page-range>502-512</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kuo]]></surname>
<given-names><![CDATA[C. J.]]></given-names>
</name>
<name>
<surname><![CDATA[Kosar]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bubble Dynamics During Boiling in Enhanced Surface Microchannels]]></article-title>
<source><![CDATA[Journal of Microelectromechanical Systems]]></source>
<year>2006</year>
<volume>15</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1514-1527</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fu]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Bubble growth, departure and the following flow pattern evolution during flow boiling in a mini-tube]]></article-title>
<source><![CDATA[International Journal of Heat and Mass Transfer]]></source>
<year>2010</year>
<volume>53</volume>
<numero>21-22</numero>
<issue>21-22</issue>
<page-range>4819-4831</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Karayiannis]]></surname>
<given-names><![CDATA[T. G.]]></given-names>
</name>
<name>
<surname><![CDATA[Shiferaw]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow patterns and heat transfer for flow boiling in small to micro diameter tubes]]></article-title>
<source><![CDATA[Heat Transfer Eng]]></source>
<year>2010</year>
<volume>31</volume>
<page-range>257-275</page-range></nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lee]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Cheung]]></surname>
<given-names><![CDATA[L. S. L.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Height effect on nucleation-site activity and size-dependent bubble dynamics in microchannel convective boiling]]></article-title>
<source><![CDATA[Journal of Micromechanics and Microengineering]]></source>
<year>2005</year>
<volume>15</volume>
<page-range>2121-2129</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cheng]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Ribatski]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New prediction methods for CO2 evaporation inside tubes Part I - A two-phase flow pattern map and a flow pattern based phenomenological model for two-phase flow frictional pressure drops]]></article-title>
<source><![CDATA[Int. J. Heat Mass Transfer]]></source>
<year>2008</year>
<volume>51</volume>
<page-range>111-124</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Harirchian]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
<name>
<surname><![CDATA[Garimella]]></surname>
<given-names><![CDATA[S. V.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comprehensive flow regime map for microchannel flow boiling with quantitative transition criteria]]></article-title>
<source><![CDATA[International Journal of Heat and Mass Transfer]]></source>
<year>2010</year>
<volume>53</volume>
<page-range>2694-2702</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Revellin]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
<name>
<surname><![CDATA[Thome]]></surname>
<given-names><![CDATA[J. R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A New Type of Diabatic Flow Pattern Map for Boiling Heat Transfer in Microchannels]]></article-title>
<source><![CDATA[Journal of Micromechanics and Microengineering]]></source>
<year>2007</year>
<volume>17</volume>
<page-range>788-796</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gnielinski]]></surname>
<given-names><![CDATA[V.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[New Equations for Heat and Mass Transfer in Turbulent Pipe and Channel Flow]]></article-title>
<source><![CDATA[International Chemical Engineering]]></source>
<year>1976</year>
<volume>16</volume>
<page-range>359-368</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bertsch]]></surname>
<given-names><![CDATA[S. S.]]></given-names>
</name>
<name>
<surname><![CDATA[Groll]]></surname>
<given-names><![CDATA[E. A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A composite heat transfer correlation for saturated flow boiling in small channels]]></article-title>
<source><![CDATA[Int. J. Heat and Mass Transfer]]></source>
<year>2009</year>
<volume>52</volume>
<page-range>2110-2118</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gungor]]></surname>
<given-names><![CDATA[K. E.]]></given-names>
</name>
<name>
<surname><![CDATA[Winterton]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A general correlation for flow boiling in tubes and annuli]]></article-title>
<source><![CDATA[Int. J. of Heat and Mass Transfer]]></source>
<year>1986</year>
<volume>29</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>351-358</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jung]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Radermacher]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Prediction of evaporation heat transfer coefficient and pressure drop of refrigerant mixtures]]></article-title>
<source><![CDATA[Int. J. of Refrigeration]]></source>
<year>1993</year>
<volume>16</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>330-338</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Z.]]></given-names>
</name>
<name>
<surname><![CDATA[Winterton]]></surname>
<given-names><![CDATA[R. S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A general correlation for saturated and subcooled flow boiling in tubes and annuli, based on a nucleate pool boiling equation]]></article-title>
<source><![CDATA[Int. J. of Heat and Mass Transfer]]></source>
<year>1991</year>
<volume>34</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>2759-2766</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steiner]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Taborek]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow Boiling Heat Transfer in Vertical Tubes Correlated by an Asymptotic Model]]></article-title>
<source><![CDATA[Heat Transfer Engineering]]></source>
<year>1992</year>
<volume>13</volume>
<page-range>43-68</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Shiferaw]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Karayiannis]]></surname>
<given-names><![CDATA[T. G.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow boiling in a 1.1 mm tube with R134a experimental results and comparison with model]]></article-title>
<source><![CDATA[Int. J. Thermal Sciences]]></source>
<year>2009</year>
<volume>48</volume>
<page-range>331-341</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Basu]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Ndao]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow Boiling of R134a in Circular Microtubes-Part II Study of Critical Heat Flux Condition]]></article-title>
<source><![CDATA[Journal of Heat Transfer]]></source>
<year>2011</year>
<volume>133</volume>
<page-range>051503-051509</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Xiande]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Rongrong]]></surname>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Correlations of Flow Boiling Heat Transfer of R-134a in Minichannels comparative study]]></article-title>
<source><![CDATA[Energy Science and Technology]]></source>
<year>2011</year>
<volume>1</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>1-15</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Basu]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
<name>
<surname><![CDATA[Ndao]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Flow Boiling of R134a in Circular Microtubes-Part I Study of Heat Transfer Characteristics]]></article-title>
<source><![CDATA[Journal of Heat Transfer]]></source>
<year>2011</year>
<volume>133</volume>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>