<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1815-5944</journal-id>
<journal-title><![CDATA[Ingeniería Mecánica]]></journal-title>
<abbrev-journal-title><![CDATA[Ingeniería Mecánica]]></abbrev-journal-title>
<issn>1815-5944</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería Mecánica. Instituto Superior Politécnico "José Antonio Echeverría"]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1815-59442017000300008</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Diseños experimentales aplicados a una bomba de calor de expansión directa con energía solar]]></article-title>
<article-title xml:lang="en"><![CDATA[Design and analysis of experiments applied to direct expansion solar assisted heat pumps]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Gorozabel-Chata]]></surname>
<given-names><![CDATA[Francis B.]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Carbonell-Morales]]></surname>
<given-names><![CDATA[Tania]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad Técnica de Manabí Departamento de Ingeniería Mecánica ]]></institution>
<addr-line><![CDATA[ Portoviejo]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad Tecnológica de la Habana José Antonio Echeverría Centro de Estudios de Tecnologías Energéticas Renovables ]]></institution>
<addr-line><![CDATA[ La Habana]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2017</year>
</pub-date>
<volume>20</volume>
<numero>3</numero>
<fpage>160</fpage>
<lpage>168</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1815-59442017000300008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1815-59442017000300008&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1815-59442017000300008&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[La bomba de calor de expansión directa con energía solar es un sistema de conversión de energía que se utiliza para aplicaciones de calentamiento de agua, calentamiento de aire para climatizar edificios, desalinización de agua, secado solar entre otras. El presente trabajo revisa los principales diseños y análisis de experimentos con la finalidad de identificar los objetivos fundamentales de todo experimento los cuales pueden ser: determinar los factores que tienen una influencia significativa, la obtención de un modelo matemático y/o la optimización de un rendimiento. Para lograr esta tarea se describen en detalle la configuración básica y avanzada de este sistemapara así caracterizar su rendimiento térmico mediante el análisis de la energía y/o el análisis basado en la exergía. Esta revisión identifica posibles líneas de investigación en el área de diseño y análisis de experimentos que permitan desarrollar esta tecnología de calentamiento de agua para aplicaciones industriales.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Direct expansion solar assisted heat pump is an energy conversion systemused for several applications among them we may cite, water heating, heating space for building, water desalination system, solar drying, amongst other. The present work review the main analysis and design of experiments with the goal of identify the fundamentals objectives of any experimental design which it may be: determining which factors affect significantly the response, obtain a mathematical model and/or optimizing a response.To reach this task, the basic and advanced configuration model of this systemare describing in details with the purpose of characterize the thermal performance of the system, the types of thermal performance analyses used are the coefficient of performance analysis and the energy-exergy efficiency analysis. This review rightly point out to identify potential area of further investigation that allow researchers develop this technology for heating water for industrial applications.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[bomba de calor]]></kwd>
<kwd lng="es"><![CDATA[energía solar]]></kwd>
<kwd lng="es"><![CDATA[expansión directa]]></kwd>
<kwd lng="es"><![CDATA[análisis exergético]]></kwd>
<kwd lng="es"><![CDATA[diseño de experimentos]]></kwd>
<kwd lng="en"><![CDATA[heat pump]]></kwd>
<kwd lng="en"><![CDATA[solar assisted]]></kwd>
<kwd lng="en"><![CDATA[direct expansion]]></kwd>
<kwd lng="en"><![CDATA[exergy analysis]]></kwd>
<kwd lng="en"><![CDATA[experimental design]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right" style="text-align:right;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>Art&iacute;culo Original</b></font></p>     <p align="justify" class="Titulo">&nbsp;</p>     <p align="justify" class="Titulo"><font style="font-family:'Verdana','sans-serif'; font-size:16.0pt; "><b>Dise&ntilde;os experimentales aplicados a una  bomba de calor de expansi&oacute;n directa con energ&iacute;a solar </b></font></p>     <p align="justify" class="TituloIngles">&nbsp;</p>     <p align="justify" class="TituloIngles"><b><font style="font-family:'Verdana','sans-serif'; font-size:14.0pt; ">Design and analysis  of experiments applied to direct expansion solar assisted heat pumps</font></b></p>     <p align="justify" class="Autor">&nbsp;</p>     <p align="justify" class="Autor">&nbsp;</p>     <p align="justify" class="Autor"><b><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Francis  B. Gorozabel-Chata<sup>I</sup>, Tania Carbonell-Morales<sup>II</sup></font></b></p>     <p align="justify" class="Filiacion"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><sup>I</sup>Universidad T&eacute;cnica de Manab&iacute;. Departamento  de Ingenier&iacute;a Mec&aacute;nica.Portoviejo, Ecuador</font></p>     <p align="justify" class="Filiacion"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><sup>II</sup>Universidad  Tecnol&oacute;gica de la Habana Jos&eacute; Antonio Echeverr&iacute;a, Centro de Estudios de Tecnolog&iacute;as  Energ&eacute;ticas Renovables. La Habana, Cuba</font></p>     ]]></body>
<body><![CDATA[<p align="justify" class="TituloResumen">&nbsp;</p>     <p align="justify" class="TituloResumen">&nbsp;</p> <hr />     <p align="justify" class="TituloResumen"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>RESUMEN</b></font></p>     <p align="justify" class="Resumen"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La  bomba de calor de expansi&oacute;n directa con energ&iacute;a solar es un sistema de  conversi&oacute;n de energ&iacute;a que se utiliza para aplicaciones de calentamiento de  agua, calentamiento de aire para climatizar edificios, desalinizaci&oacute;n de agua,  secado solar entre otras. El presente trabajo revisa los principales dise&ntilde;os y  an&aacute;lisis de experimentos con la finalidad de identificar los objetivos  fundamentales de todo experimento los cuales pueden ser: determinar los  factores que tienen una influencia significativa, la obtenci&oacute;n de un modelo  matem&aacute;tico y/o la optimizaci&oacute;n de un rendimiento. Para lograr esta tarea se  describen en detalle la configuraci&oacute;n b&aacute;sica y avanzada de este sistemapara as&iacute;  caracterizar su rendimiento t&eacute;rmico mediante el an&aacute;lisis de la energ&iacute;a y/o el  an&aacute;lisis basado en la exerg&iacute;a. Esta revisi&oacute;n identifica posibles l&iacute;neas de  investigaci&oacute;n en el &aacute;rea de dise&ntilde;o y an&aacute;lisis de experimentos que permitan  desarrollar esta tecnolog&iacute;a de calentamiento de agua para aplicaciones  industriales.&nbsp; </font></p>     <p align="justify" class="PalabrasClaves"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>Palabras claves:</b> bomba de calor, energ&iacute;a solar, expansi&oacute;n directa, an&aacute;lisis exerg&eacute;tico,  dise&ntilde;o de experimentos</font></p> <hr />     <p align="justify" class="TituloResumen"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>ABSTRACT</b></font></p>     <p align="justify" class="Resumen"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Direct expansion solar assisted heat pump is an energy  conversion systemused for several applications among them we may cite, water  heating, heating space for building, water desalination system, solar drying,  amongst other. The present work review the main analysis and design of  experiments with the goal of identify the fundamentals objectives of any  experimental design which it may be: determining which factors affect  significantly the response, obtain a mathematical model and/or optimizing a  response.To reach this task, the basic and advanced configuration model of this  systemare describing in details with the purpose of characterize the thermal  performance of the system, the types of thermal performance analyses used are  the coefficient of performance analysis and the energy-exergy efficiency analysis.  This review rightly point out to identify potential area of further  investigation that allow researchers develop this technology for heating water  for industrial applications.</font></p>     <p align="justify" class="Tituloclaves"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>Key words:</b> heat pump,  solar assisted, direct expansion, exergy analysis, experimental design. </font></p> <hr />     <p align="justify" class="Subtitulo">&nbsp;</p>     <p align="justify" class="Subtitulo">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify" class="Subtitulo"><font style="font-family:'Verdana','sans-serif'; font-size:14.0pt; "><b>INTRODUCCI&Oacute;N</b></font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Una bomba de calor de expansi&oacute;n directa con  asistencia de energ&iacute;a solar (BCAES-ED) es una tecnolog&iacute;a que combina un sistema  convencional de calentamiento solar con una bomba de calor, con la  particularidad de que el colector solar y el evaporador se integran en una  misma unidad, el fluido de trabajo es un refrigerante el cual se expande en un  panel colector/evaporador por donde pasa a una fase de transici&oacute;n de l&iacute;quido a  vapor debido a la ganancia de energ&iacute;a solar. Existen dos tipos de  configuraciones seg&uacute;n Omojaro et al. [1] cuando se refieren a una BCAES-ED, la  b&aacute;sica y la avanzada, en el modelo de configuraci&oacute;n b&aacute;sica el sistema trabaja  con el ciclo mec&aacute;nico de compresi&oacute;n de vapor a una etapa de compresi&oacute;n y en el  modelo de configuraci&oacute;n avanzada utiliza dos etapas de compresi&oacute;n. Chaturvedi  et al. [2] marcan una clara l&iacute;nea divisoria entre las dos configuraciones  cuando concluyen que para cumplir una demanda a temperaturas mayores a 70 &ordm;C  una BCAES-ED que tenga una configuraci&oacute;n b&aacute;sica pierde eficiencia y ventajas  econ&oacute;micas sobre los sistemas el&eacute;ctricos. </font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Para caracterizar el desempe&ntilde;o t&eacute;rmico de una  BCAES-ED se utiliza dos tipos de an&aacute;lisis, el an&aacute;lisis de energ&iacute;a, el cual  eval&uacute;a el coeficiente de desempe&ntilde;o (COP) del sistema y los m&eacute;todos basados en  la exerg&iacute;a, el cual identifica el o los componentes del sistema que tienen un  bajo desempe&ntilde;o lo que permite implementar mejoras en el mismo. Desde que se  concibi&oacute; la idea en 1955 de que la energ&iacute;a solar puede evaporar un refrigerante  que circula a trav&eacute;s de una bomba de calor utilizando un colector solar como  evaporador es solo a finales de la d&eacute;cada de 1970 en que se empiezan a  desarrollar estudios anal&iacute;ticos, te&oacute;ricos, num&eacute;ricos y experimentales. Una  amplia revisi&oacute;n sobre la actualidad y perspectivas de esta tecnolog&iacute;a la  presentan Gorozabel y Carbonell [3].</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">El objetivo del presente estudio se enfoca en  exponer los dise&ntilde;os experimentales que se aplican com&uacute;nmente a la tecnolog&iacute;a de  calentamiento de agua con una BCAES-ED para desarrollar, mejorar y evaluar este  sistema de conversi&oacute;n de energ&iacute;a, usando la caracterizaci&oacute;n de su desempe&ntilde;o  t&eacute;rmico mediante el an&aacute;lisis de energ&iacute;a y/o los m&eacute;todos basados en la exerg&iacute;a.  Para cumplir con este objetivo se pretende describir el problema de  investigaci&oacute;n, precisar los objetivos del experimento, caracterizar el dise&ntilde;o  experimental y valorar las conclusiones del experimento que los autores han  reportado en cada uno de los art&iacute;culos cient&iacute;ficos objetos de esta revisi&oacute;n. </font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La BCAES-ED es una tecnolog&iacute;a con mucho  potencial en el mercando mundial, el cual est&aacute; limitado todav&iacute;a por algunas  barreras econ&oacute;micas y t&eacute;cnicas, que pueden ser superadas con pol&iacute;ticas de  estado que permitan el desarrollo de la tecnolog&iacute;a seg&uacute;n concluyen Raisul Islam  et al. [4]. Buker y Riffat [5], indican que los promedios de los estudios  realizados demuestran que la tecnolog&iacute;a de bombas de calor y energ&iacute;a solar  t&eacute;rmica tienen el potencial de proveer una alternativa efectiva para diferentes  climas y configuraciones. </font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La presente revisi&oacute;n identifica futuros trabajos  de investigaci&oacute;n que permitan incrementar la eficiencia energ&eacute;tica y exerg&eacute;tica  de la configuraci&oacute;n b&aacute;sica, as&iacute; como tambi&eacute;n de la configuraci&oacute;n avanzada de  una BCAES-ED como tecnolog&iacute;a para calentamiento de agua, el cual muestra un  gran potencial de desarrollo y una alternativa efectiva para diferentes climas  alrededor del mundo. </font></p>     <p align="justify" class="Subtitulo"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>Modelo  de configuraci&oacute;n b&aacute;sica y avanzada de una BCAES-ED</b></font></p>     <p align="justify"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Una  BCAES-ED est&aacute; compuesta por cuatro componentes principales: el panel  colector/evaporador, el compresor, la v&aacute;lvula de expansi&oacute;n y el tanque  intercambiador de calor conocido como condensador. Amin et al. [6] realizan un  exhaustivo estudio sobre el rendimiento t&eacute;rmico de un colector/evaporador solar  de dos fases de tipo desnudo cuyos resultados muestran que, en vez de perder  energ&iacute;a al ambiente, gana una cantidad significativa de energ&iacute;a debido a la  baja temperatura de operaci&oacute;n del colector; Gorozabel y Carbonell [7] coinciden  con estos resultados cuando analizan experimentalmente el coeficiente de  desempe&ntilde;o para zonas tropicales caracterizados por temperaturas ambientales  mayores a 25 &deg;C.<b> </b></font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La mayor&iacute;a de las bombas de calor disponibles  comercialmente operan en el ciclo mec&aacute;nico de compresi&oacute;n de vapor como se  muestra en la <a href="/img/revistas/im/v20n3/f0108317.gif">figura 1a</a>, donde el fluido de trabajo es un refrigerante. Un an&aacute;lisis num&eacute;rico es realizado por Molinari et al. [8]  con la finalidad de evaluar el refrigerante 407-C mientras que Kong et al.[9]  lo realiza para el Refrigerante 410-A. Entre las principales aplicaciones de  una BCAES-ED se encuentran la desalinizaci&oacute;n de agua reportada por Amin et al.  [10] y calentamiento de piscinas para nadar presentada por Starke et al. [11].</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Una BCAES-ED se muestra en la <a href="/img/revistas/im/v20n3/f0208317.gif">figura 2</a>, el cual trabaja con el ciclo  mec&aacute;nico de compresi&oacute;n de vapor que se ilustra en la <a href="/img/revistas/im/v20n3/f0108317.gif">figura 1a</a>, y cuyos  procesos termodin&aacute;micos se muestran en la <a href="/img/revistas/im/v20n3/f0108317.gif">figura 1b</a>. En la actualidad Scarpa et  al. [12] y Tagliafico et al. [13] han logrado desarrollar un enfoque de estado  estable basado en el ciclo de Carnot y el concepto de eficiencia basado en la  segunda ley de la termodin&aacute;mica para relacionar las principales caracter&iacute;sticas  del sistema y sus interrelaciones con el ambiente sin necesidad de calcular las  propiedades del fluido refrigerante.</font></p>     
]]></body>
<body><![CDATA[<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Un an&aacute;lisis te&oacute;rico de BCAES-ED que  utiliza dos etapas de compresi&oacute;n para alcanzar aplicaciones de temperaturas correspondiente  entre 60 &ordm;C - 90 &ordm;C es propuesto por Chaturvedi et al. [14]. Un ciclo mec&aacute;nico  de compresi&oacute;n de dos etapas se muestra en la <a href="/img/revistas/im/v20n3/f0308317.gif">figura 3a</a> y un diagrama T-s en la  <a href="/img/revistas/im/v20n3/f0308317.gif">figura 3b</a>. El ciclo que se muestra en la <a href="/img/revistas/im/v20n3/f0308317.gif">figura 3a</a>, asume que no existe ca&iacute;da  de presi&oacute;n en la transferencia de calor en el panel colector/evaporador y en el  condensador. El proceso de compresi&oacute;n se asume no isentr&oacute;pico y es  caracterizado para los dos compresores por la eficiencia de un compresor  adiab&aacute;tico. Tambi&eacute;n la ca&iacute;da de presi&oacute;n en las tuber&iacute;as de conexi&oacute;n es  depreciable.</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">En  general el <i>COP</i> para una configuraci&oacute;n  avanzada de una BCAES-ED est&aacute; en funci&oacute;n de varios par&aacute;metros, como el fluido refrigerante,  la eficiencia de los componentes del sistema, la temperatura de la fuente y del  disipador. Chaturvedi et al. [14] encuentran una mejora significativa del  coeficiente de operaci&oacute;n del sistema cuando se usa las dos etapas de compresi&oacute;n  para alcanzar altas temperaturas de condensaci&oacute;n. Sin embargo, a los mismos  niveles de temperatura el sistema de dos etapas requiere un &aacute;rea de colector  mayor que los sistemas de una sola etapa.</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La tecnolog&iacute;a de BCAES-ED es en la actualidad de  sumo inter&eacute;s para investigadores quienes ven un gran potencial de desarrollo en  la configuraci&oacute;n b&aacute;sica como en la avanzada, as&iacute; lo demuestran los estudios anal&iacute;ticos,  num&eacute;ricos y experimentales reportados en los &uacute;ltimos cinco a&ntilde;os con la  finalidad de mejorar su rendimiento t&eacute;rmico e introducir nuevas aplicaciones  como desalinizaci&oacute;n de agua, calentamiento de piscinas y secado solar.</font></p>     <p align="justify" class="Subtitulo"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>An&aacute;lisis  de energ&iacute;a y m&eacute;todos de an&aacute;lisis basado en la exerg&iacute;a de una BCAES-ED</b></font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">El  rendimiento t&eacute;rmico de una bomba de calor es caracterizado por el coeficiente  de desempe&ntilde;o COP definido:</font></p>     <p align="center" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e1" id="e1"></a><img src="/img/revistas/im/v20n3/e0108317.gif" width="86" height="41" longdesc="/img/revistas/im/v20n3/e0108317.gif" />(1)</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Donde <i>W<sub>c</sub></i> es la potencia de  ingreso del compresor y <i>Q<sub>H</sub></i> es el flujo de calor entregado, en general, el <i>COP</i> de una bomba de calor est&aacute; en funci&oacute;n de varios par&aacute;metros  entre los que podemos mencionar al refrigerante, la eficiencia de los  componentes estructurales del sistema, la temperatura de la fuente y del disipador  de calor.</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">En  una bomba de calor de dos etapas se usa una versi&oacute;n modificada de la <a href="#e1">ecuaci&oacute;n 1</a> para calcular el <i>COP</i> que tome en  cuenta el efecto de la doble etapa en el sistema de configuraci&oacute;n avanzado</font></p>     <p align="center" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e" id="e"></a><img src="/img/revistas/im/v20n3/e0208317.gif" width="91" height="41" longdesc="/img/revistas/im/v20n3/e0208317.gif" />(2)</font></p>     
<p align="justify"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Donde &Sigma;<i>W </i>es el trabajo total  que ingresa y se calcula de la siguiente manera</font></p>     ]]></body>
<body><![CDATA[<p align="center"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e3" id="e3"></a><img src="/img/revistas/im/v20n3/e0308317.gif" width="123" height="19" longdesc="/img/revistas/im/v20n3/e0308317.gif" />(3)</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Se  entiende por exerg&iacute;a al trabajo te&oacute;rico m&aacute;ximo disponible que se obtiene de un  sistema de conversi&oacute;n de energ&iacute;a cuando este es llevado a un equilibrio  termodin&aacute;mico con el ambiente, mientras interact&uacute;a &uacute;nicamente con este  ambiente. Para realizar un an&aacute;lisis de eficiencia y p&eacute;rdidas es necesario  expresar en forma general la ecuaci&oacute;n de balance de energ&iacute;a que se muestra a  continuaci&oacute;n. </font></p>     <p align="center" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e4" id="e4"></a><img src="/img/revistas/im/v20n3/e0408317.gif" width="110" height="27" longdesc="/img/revistas/im/v20n3/e0408317.gif" />(4)</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Para Tsatsaronis  y Morosuk [15]  los an&aacute;lisis exerg&eacute;ticos identifican el lugar, la magnitud y las causas de las  ineficiencias termodin&aacute;micas,estas ineficiencias termodin&aacute;micas vienen en forma  de destrucci&oacute;n o p&eacute;rdidas de exerg&iacute;a, la destrucci&oacute;n de la exerg&iacute;a se debe a  las irreversibilidades existentes dentro del sistema, y las p&eacute;rdidas de exerg&iacute;a  se relacionan con la exerg&iacute;a perdida en el ambiente. Para identificar y  cuantificar las p&eacute;rdidas cuando se realiza un an&aacute;lisis exerg&eacute;tico ya sea del  sistema, proceso o componente se debe calcular la exerg&iacute;a destruida, la exerg&iacute;a  suministrada y la eficiencia exerg&eacute;tica.</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La  exerg&iacute;a destruida se calcula mediante la siguiente ecuaci&oacute;n:</font></p>     <p align="center" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e5" id="e5"></a><img src="/img/revistas/im/v20n3/e0508317.gif" width="240" height="24" longdesc="/img/revistas/im/v20n3/e0508317.gif" />(5)</font></p>     
<p align="justify" class="MsoListParagraph" style="text-align:justify;line-height:normal;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La exerg&iacute;a suministrada se expresa mediante la  siguiente ecuaci&oacute;n </font></p>     <p align="center" class="MsoListParagraph" style="text-align:center;line-height:normal;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e6" id="e6"></a><img src="/img/revistas/im/v20n3/e0608317.gif" width="298" height="27" longdesc="/img/revistas/im/v20n3/e0608317.gif" />(6)</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Donde<i> <a name="e9" id="e9"></a></i><img src="/img/revistas/im/v20n3/e0908317.gif" width="18" height="15" longdesc="/img/revistas/im/v20n3/e0908317.gif" /> es el flujo de masa del refrigerante, <i>h</i> es la entalp&iacute;a espec&iacute;fica, <i>s</i> es la entrop&iacute;a espec&iacute;fica, <i>T</i> es la temperatura, mientras que el  sub&iacute;ndice o significa el estado del punto muerto del refrigerante. La  eficiencia exergetica ser&aacute; el radio entre la exerg&iacute;a recuperada y la exerg&iacute;a  suministrada.</font></p>     
<p align="center" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e7" id="e7"></a><img src="/img/revistas/im/v20n3/e0708317.gif" width="150" height="50" longdesc="/img/revistas/im/v20n3/e0708317.gif" />(7)</font></p>     
]]></body>
<body><![CDATA[<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Seg&uacute;n  Lazzaretto y Tsatsaronis [16] un an&aacute;lisis exergo-econ&oacute;mico es una combinaci&oacute;n  &uacute;nica de an&aacute;lisis de exerg&iacute;a y de costos conducido a nivel de cada componente,  que permite al dise&ntilde;ador o al investigador de un sistema de conversi&oacute;n de  energ&iacute;a contar con informaci&oacute;n crucial para el dise&ntilde;o de un sistema  costo-efectivo. La exergo-econom&iacute;a es un enfoque para reducir costos basado en  la exerg&iacute;a que utiliza el principio de &ldquo;coste de exerg&iacute;a&rdquo;. Este principio  establece que la exerg&iacute;a es la &uacute;nica base racional para asignar valores  monetarios al transporte de energ&iacute;a y a las ineficiencias termodin&aacute;micas dentro  del sistema. El principio del costo de exerg&iacute;a es la base para calcular los  costos asociados con cada material y cada flujo de energ&iacute;a en un sistema de  conversi&oacute;n de energ&iacute;a. Un an&aacute;lisis exergo-econ&oacute;mico completo consiste primero  en un an&aacute;lisis exerg&eacute;tico, luego un an&aacute;lisis econ&oacute;mico y por ultimo una  evaluaci&oacute;n exergo-econ&oacute;mica. </font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Un  an&aacute;lisis exergo-ambiental seg&uacute;n Meyer et al. [17] descansa en la premisa de que  la exerg&iacute;a es la &uacute;nica base racional para asignar no solo un valor monetario,  sino tambi&eacute;n un valor de impacto ambiental al transporte de energ&iacute;a y a las  ineficiencias dentro de cada componente, esto se lo conoce como coste  exergo-ambiental. Un an&aacute;lisis exergo-ambiental consiste en un an&aacute;lisis de  exerg&iacute;a, una evaluaci&oacute;n del ciclo de vida de cada componente relevante del  sistema y para todas las corrientes relevantes que ingresan al sistema y por  &uacute;ltimo el c&aacute;lculo del impacto ambiental asociado con cada flujo de exerg&iacute;a y  con la destrucci&oacute;n de la exerg&iacute;a dentro de cada componente del sistema.</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Seg&uacute;n  Tsatsaronis [18] se conoce como An&aacute;lisis Avanzado cuando se realiza una  divisi&oacute;n de la parte evitable/inevitable y de la parte end&oacute;gena/ex&oacute;gena de la  destrucci&oacute;n de la exerg&iacute;a, del costo de inversi&oacute;n y del componente constructivo  relacionado al impacto ambiental en cada componente de importancia en el  sistema as&iacute; como tambi&eacute;n&nbsp; al costo de la  destrucci&oacute;n de la exerg&iacute;a y al impacto ambiental asociado con la destrucci&oacute;n de  la exerg&iacute;a; en este an&aacute;lisis se estiman las interacciones entre diferentes  componentes para mejorar la calidad de las conclusiones obtenidas de una  evaluaci&oacute;n exergetica, exergo-econ&oacute;mica o exergo-ambiental.Entre las  principales aplicaciones reportadas por los investigadores se resalta la de  Gungor et al. [19, 20] quienes estudian la destrucci&oacute;n de la exerg&iacute;a en la  parte evitable e inevitable, as&iacute; como presentan un an&aacute;lisis exergo-econ&oacute;mico  avanzado de una bomba de calor impulsada por un motor a gas.</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Los an&aacute;lisis de exerg&iacute;a y los an&aacute;lisis basados  en la exerg&iacute;a son herramientas de importancia a la hora de evaluar,  desarrollar, y optimizar sistemas de conversi&oacute;n de energ&iacute;a como lo es una  BCAES-ED en su configuraci&oacute;n b&aacute;sica y avanzada. Los an&aacute;lisis avanzados basados  en la exerg&iacute;a tienen el potencial de mejorar la calidad de las conclusiones de  una evaluaci&oacute;n exergetica, exergoeconomica, y exergoambiental aplicadas a una  BCAES-ED.</font></p>     <p align="justify" class="Subtitulo"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>An&aacute;lisis  y dise&ntilde;o de experimentos en una BCAES-ED</b></font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Un  dise&ntilde;o experimental pretende obtener la m&aacute;xima informaci&oacute;n de un proceso, de la  forma m&aacute;s r&aacute;pida, econ&oacute;mica, simple y precisa,entre los objetivos de un&nbsp; dise&ntilde;o experimental, seg&uacute;n Montgomery [21],  se tiene en primer lugar&nbsp; identificar los  factores m&aacute;s influyentes en un rendimiento, en segundo lugar es relacionar las  variables independientes o factores con la variable dependiente o rendimiento,  y el tercer objetivo es determinar la regi&oacute;n de los factores m&aacute;s importantes  que conducen al mejor rendimiento posible. En la <a href="/img/revistas/im/v20n3/t0108317.gif">tabla 1</a> se muestran diversos  estudios experimentales sobre an&aacute;lisis de energ&iacute;a y basados en la exerg&iacute;a  aplicados a una configuraci&oacute;n b&aacute;sica y avanzada de una BCAES-ED contrastados  con los objetivos de un dise&ntilde;o experimental.</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">En  la <a href="/img/revistas/im/v20n3/t0208317.gif">tabla 2</a> se muestran los factores investigados que m&aacute;s influyen en el  rendimiento de una BCAE-ED en donde el COP es el rendimiento m&aacute;s investigado y  la temperatura de evaporaci&oacute;n del refrigerante, la radiaci&oacute;n solar, la  temperatura del agua al ingreso y a la salida del condensador, la temperatura  ambiental est&aacute;nentre los factores m&aacute;s investigados.</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Al  objetivo dedeterminar los factores que influyen significativamente en el desempe&ntilde;o  t&eacute;rmico de una BCAES-ED podemos resumir las siguientes conclusiones: Kush [22] recomiendan evitar temperaturas de evaporaci&oacute;n mayores de  25 &ordm;C - 30 &ordm;C debido a una mejora marginal del<i> COP</i> ya que estas imponen una penalidad en la eficiencia del  colector. Chaturvedi y Shen [23] demuestran la importancia de acoplar  correctamente el &aacute;rea del colector solar y la masa de bombeo del compresor. M&aacute;s  adelante Chaturvedi et al. [24] encuentran mejoras significativas en el  rendimiento del sistema bajando la velocidad del compresor cuando la temperatura  ambiental se incrementa. De los estudios realizados por Hawlader et al.  [26],Kuang et al. [27] y Zhu et al. [35] el COP del sistema es afectado significativamente,  por los siguientes factores: velocidad del compresor, la radiaci&oacute;n solar, el  &aacute;rea del colector yel volumen almacenado.Li et al. [29] encuentran que el  sistema alcanzarendimientos t&eacute;rmicos importantesen condiciones clim&aacute;ticas  favorables y valores de COP entre 3,11 y 3,23 en condiciones de radiaci&oacute;n solar  cero. Sun et al. [38] concluyen que un an&aacute;lisis de rendimiento anual el COP  promedio de una BCAES-ED es mucho mayor que el sistema convencional. Las  configuraciones y los tipos de colectores afectan el COP del sistema seg&uacute;n Zhu  et al. [35], Garg et al. [36], y Sun et al. [37].</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">En  la <a href="/img/revistas/im/v20n3/t0308317.gif">tabla 3</a> se revisan los modelos matem&aacute;ticos desarrolladospara mejorar el  desempe&ntilde;o t&eacute;rmico de una BCAES-ED, entre los principales objetivos propuestos  por los investigadores tenemos a Ito et al. [25] quien determina el efecto que  tiene el espesor de cobre y la distancia entre tubos en el plato absorvedor de  una BCAES-ED. Soldo et al [28] desarrollan un modelo matem&aacute;tico que permita la  optimizaci&oacute;n de los componentes del sistema y los par&aacute;metros de operaci&oacute;n.  Fern&aacute;ndez-Seara et al. [32] determinan el efecto deno tener radiaci&oacute;n solar en  el desempe&ntilde;o t&eacute;rmico de una BCAES-ED. Moreno Rodr&iacute;guez et al. [33-34]  desarrollan y validan un modelo que determina los par&aacute;metros de operaci&oacute;n de  una BCAES-ED y Cervantes y Torres Reyes [40]&nbsp;  determinan una expresi&oacute;n para describir el COP &oacute;ptimo considerando las  irreversibilidades internas y externas en la optimizaci&oacute;n termodin&aacute;mica de una  BCAES-ED.</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Entre las principales conclusiones  de obtener un modelo matem&aacute;tico para mejorar el rendimiento de una BCAES-ED  tenemos a Ito et al [25] quienes indican que el espesor del plato de cobre de  1mm usado en el experimento se puede reducir a 0,5 mm con muy poca reducci&oacute;n  del COP, adem&aacute;s la distancia entre los tubos de cobre en el plato de 100 mm  puede ser cambiado a 190 mm obteniendo una reducci&oacute;n del COP del 4 %. Soldo et  al [28] concluyen que, para prevenir un alto deterioro del COP debido a las  inconsistencias entre las condiciones clim&aacute;ticas y la radiaci&oacute;n solar, cada  componente del sistema debe optimizarse en funci&oacute;n del &aacute;rea del colector solar,  la capacidad del compresor y las temperaturas de evaporaci&oacute;n y condensaci&oacute;n.  Fern&aacute;ndez Seara et al [32] obtienen un COP de 3,23 cuando se eval&uacute;a en  condici&oacute;n de cero radiaciones solares. Moreno Rodr&iacute;guez et al [33, 34]  encuentran un COP de 1,7 y 2,9 para una temperatura del tanque de agua de 51  &deg;C. Cervantes y Torres Reyes [40] encuentran que el modelo obtenido representa  muy de cerca el rendimiento real del sistema. </font></p>     ]]></body>
<body><![CDATA[<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">En la <a href="/img/revistas/im/v20n3/t0408317.gif">tabla 4</a> se muestra un resumen de los an&aacute;lisis  basados en la exerg&iacute;a aplicados a una configuraci&oacute;n b&aacute;sica y avanzada de una  BCAES-ED, entre los varios objetivos de las investigaciones revisadas se  encuentran determinar  la eficiencia exergetica[39, 41-43], la destrucci&oacute;n de exerg&iacute;a de cada  componente[39] y la destrucci&oacute;n total de exerg&iacute;a [39] con la finalidad de  identificar las principales fuentes de irreversibilidad en una BCAES-ED y en  algunos casos comparar el uso de dos refrigerantes [45] o determinar una  expresi&oacute;n [40] para describir el COP &oacute;ptimo considerando las irreversibilidades  internas y externas en la optimizaci&oacute;n termodin&aacute;mica de una BCAES-ED.</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Al  objetivo de optimizar el desempe&ntilde;o t&eacute;rmico mediante el uso de an&aacute;lisis basados  en la exerg&iacute;ade una BCAES-ED podemos resumir las siguientes  conclusiones: Torres Reyes et al [39] encuentran que la operaci&oacute;n de una BCAES-ED muestra  una baja eficiencia exerg&eacute;tica, la mayor destrucci&oacute;n de la exerg&iacute;a ocurre en el  panel colector/evaporador solar. Cervantes y Torres Reyes [41] tambi&eacute;n  coinciden en que la principal fuente de irreversibilidad es en el panel  colector/evaporador solar resaltando que la radiaci&oacute;n solar que ingresa no es  totalmente aprovechada. Li et al. [42] al contrario encuentran que la mayor  p&eacute;rdida de exerg&iacute;a ocurre en el compresor, seguida por el colector/evaporador  solar, condensador y v&aacute;lvula de expansi&oacute;n respectivamente. Kara et al. [43]  concluyen quela eficiencia exerg&eacute;tica de los componentes individuales de una  BCAES-ED est&aacute;n en el rango de 10,74% a 88,87 %. Torres Reyes y Cervantes [40]  obtienen un modelo donde representa muy de cerca el rendimiento real del  sistema. Mohanraj et al [44] confirman con sus resultados que es aceptable  utilizar redes neuronales artificiales para predecir la destrucci&oacute;n de la  exerg&iacute;a y la eficiencia exerg&eacute;tica de una BCAES-ED. Mohanraj et al.[45]  encuentran que el rendimiento exerg&eacute;tico promedio de una BCAES-ED que funciona  con RM30 fue ligeramente menor en comparaci&oacute;n con el R-22. Sin embargo, el RM30  es una alternativa amigable con la capa de ozono cuando el R22 salga del  mercado.</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Los  estudios experimentales que se presentan desde la <a href="/img/revistas/im/v20n3/t0108317.gif">tabla 1</a> hasta la <a href="/img/revistas/im/v20n3/t0408317.gif">4</a>, y que se obtienen  de las referencias [22-45] concuerdan con recientes estudios anal&iacute;ticos y  num&eacute;ricos presentados por diversos autores entre los que podemos citar a  Yousefi et al. [46] quienes analizan y optimizan termodin&aacute;micamente una  BCAES-ED con aplicaci&oacute;n a calentamiento de agua, Kumar et al. [47] y Paradeshi  et al. [48] quienesrealizan estudios param&eacute;tricos de esta tecnolog&iacute;a  confirmando el uso de redes neuronales artificiales integrada con algoritmos  gen&eacute;ticos para predecir el rendimiento t&eacute;rmico de una BCAES-ED, as&iacute; como  caracterizar su funcionamiento en un ambiente c&aacute;lido y h&uacute;medo, Malali et al  [49] logran desarrollar una herramienta anal&iacute;tica mediante la combinaci&oacute;n de  dos modelos para determinar el rendimiento t&eacute;rmico de una BCAES-ED </font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Los  dise&ntilde;os y an&aacute;lisis de experimentos aplicados a una BCAES-ED han permitido  identificar los factores que influyen significativamente en el desempe&ntilde;o  t&eacute;rmico de una BCAES-ED, as&iacute; como obtener modelos matem&aacute;ticos para predecir el  comportamiento de la tecnolog&iacute;a y optimizar el funcionamiento de esta. Los  an&aacute;lisis de energ&iacute;a y los an&aacute;lisis exerg&eacute;ticos convencionales son los m&aacute;s  utilizados por los investigadores.<b></b></font></p>     <p align="justify" class="Subtitulo"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><b>Incertidumbre  experimental</b></font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">La incertidumbre de dise&ntilde;os experimentales  relacionados a una BCAES-ED se encuentran resumidos en la <a href="/img/revistas/im/v20n3/t0508317.gif">Tabla 5</a>, y han sido  estimados seg&uacute;n Holman [50], la presi&oacute;n, la temperatura, la radiaci&oacute;n solar, el  consumo de potencia, el flujo de masa del refrigerante y la velocidad del aire  son medidos con los instrumentos catalogados en la columna sensor. La  incertidumbre que se presentan en el c&aacute;lculo de un par&aacute;metro en funci&oacute;n de  varias variables independientes es dada por la siguiente ecuaci&oacute;n:</font></p>     
<p align="center"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><a name="e8" id="e8"></a><img src="/img/revistas/im/v20n3/e0808317.gif" width="345" height="53" longdesc="/img/revistas/im/v20n3/e0808317.gif" />(8)</font></p>     
<p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Donde&nbsp; es una funci&oacute;n dada, &nbsp;es la  incertidumbre total, x<sub>1</sub>, x<sub>2</sub>, &hellip; x<sub>n</sub> son las  variables independientes, y <i>w</i><sub>1</sub>, <i>w</i><sub>2</sub>, <i>w</i><sub>3</sub> es la incertidumbre en las variables independientes.</font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">En los experimentos realizados sobre una  BCAES-ED se obtienen datos con muestra &uacute;nicas cuyas incertidumbres no se pueden  descubrir por repetici&oacute;n, al contrario de datos con muestras m&uacute;ltiples cuyos  resultados son confiables gracias a las aplicaciones de m&eacute;todos estad&iacute;sticos.  Entre los tipos de errores que pueden causar incertidumbre tenemos aquellas  equivocaciones causadas por los instrumentos de medici&oacute;n, por errores fijos o  sistem&aacute;ticos y aquellos causados por errores aleatorios. Los errores de los  par&aacute;metros investigados reportan incertidumbres en el rango de 4,1 a 8,1 %.</font></p>     <p align="justify" class="Subtitulo">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify" class="Subtitulo"><font style="font-family:'Verdana','sans-serif'; font-size:14.0pt; "><b>CONCLUSIONES</b></font></p>     <p align="justify" class="Texto"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">De la literatura revisada sobre an&aacute;lisis y  dise&ntilde;o de experimentos sobre una BCAES-ED se muestra que el modelo de  configuraci&oacute;n b&aacute;sica ha sido ampliamente estudiado con respecto al an&aacute;lisis de  energ&iacute;a, logrando caracterizar los factores que influyen significativamente en  el rendimiento t&eacute;rmico, as&iacute; como obtener modelos matem&aacute;ticos y optimizar la  eficiencia de este sistema energ&eacute;tico. Con relaci&oacute;n a los an&aacute;lisis basados en  la exerg&iacute;a el modelo de configuraci&oacute;n b&aacute;sica muestra resultados en an&aacute;lisis de  exerg&iacute;a convencional, quedando por explorar an&aacute;lisis exergo-econ&oacute;micos y  exergo-ambientales de esta tecnolog&iacute;a, as&iacute; como an&aacute;lisis avanzados que logren  mejorar las conclusiones a la hora de desarrollar, evaluar y mejorar este  sistema de conversi&oacute;n de energ&iacute;a. En relaci&oacute;n a los modelos de configuraci&oacute;n  avanzada, la literatura revisada no reporta dise&ntilde;os experimentales de an&aacute;lisis  de energ&iacute;a y an&aacute;lisis basado en la exerg&iacute;a que permitan demostrar los  beneficios de esta tecnolog&iacute;a reportados en an&aacute;lisis te&oacute;ricos.</font></p>     <p align="justify" class="Subtitulo">&nbsp;</p>     <p align="justify" class="Subtitulo"><font style="font-family:'Verdana','sans-serif'; font-size:14.0pt; "><b>REFERENCIAS</b></font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">1. Omojaro P, Breitkopf C. Direct expansion solar  assisted heat pumps: A review of applications and recent research. Renewable  and Sustainable Energy Reviews. 2013;22:33-45.     </font></p>     <p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">2. Chaturvedi SK, Gagrani VD, Abdel-Salam TM.  Solar-assisted heat pump &ndash; A sustainable system for low-temperature water  heating applications. Energy Conversion and Management. 2014;77:550-7. </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">3. Gorozabel-Chata  F-B, Carbonell-Morales T. Actualidad y perspectivas de una bomba de calor de  expansi&oacute;n directa con energ&iacute;a solar. Ingenier&iacute;a Mec&aacute;nica. 2016;19(1):49-58.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">4. Raisul Islam M, Sumathy K, Ullah Khan S.  Solar water heating systems and their market trends. Renewable  and Sustainable Energy Reviews.  2013;17:1-25.     </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">5. Buker Mahmut S, Riffat SB. Solar assisted  heat pump systems for low temperature water heating applications: A systematic  review. Renewable and Sustainable Energy Reviews. 2016; 3(55):399-413.     </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">6. Amin  ZM, Hawlader MNA, Shaochum Y. Analysis and Modeling of Solar  Evaporator-Collector. IIUM Engineering. 2015;16(2):13-29.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">7. Gorozabel  Chata FB, Carbonell Morales T. An&aacute;lisis del Coeficiente de Desempe&ntilde;o de una  Bomba de Calor de Expansi&oacute;n Directa con Energ&iacute;a Solar. In: XVIII Convenci&oacute;n  Cient&iacute;fica de Ingenier&iacute;a y Arquitectura; La Habana Cuba: Universidad  Tecnol&oacute;gica de La Habana; 2016. [Citado octubre de 2016] Disponible en: <a href="https://www.researchgate.net/publication/311294467_ANALISIS_DEL_COEFICIENTE_DE_DESEMPENO_DE_UNA_BOMBA_DE_CALOR_DE_EXPANSION_DIRECTA_CON_ENERGIA_SOLAR" target="_blank">https://www.researchgate.net/publication/311294467_ANALISIS_DEL_COEFICIENTE_DE_DESEMPENO_DE_UNA_BOMBA_DE_CALOR_DE_EXPANSION_DIRECTA_CON_ENERGIA_SOLAR</a> </font><!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">8. Molinaroli L, Joppolo CM, De Antonellis S.  Numerical Analysis of the Use of R-407C in Direct Expansion Solar Assisted Heat  Pump. Energy Procedia. 2014;48:938-45.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">9. Kong  XQ, Li Y, Lin L, et al. Modeling  evaluation of a direct-expansion solar-assisted heat pump water heater using  R410A. International Journal of Refrigeration. 2017; 76(Abril 2017):136-146</font><!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">10. Amin ZM, Hawlader MNA. Analysis of solar  desalination system using heat pump. Renewable Energy. 2015;74:116-23.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">11. Starke AR, Cardemil JM, Escobar R, et al.  Thermal analysis of solar-assisted heat pumps for swimming pool heating.  Journal of the Brazilian Society of Mechanical Sciences and Engineering. 2017;  39(6):2289-2306.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">12. Scarpa F, Tagliafico LA, Bianco V. A novel  steady-state approach for the analysis of gas-burner supplemented direct  expansion solar assisted heat pumps. Solar Energy. 2013; 96:227-238.    </font></p>     <p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">13. Tagliafico LA, Scarpa F, Valsuani F. Direct  expansion solar assisted heat pumps &ndash; A clean steady state approach for overall  performance analysis. Applied Thermal Engineering. 2014;66(1-2):216-26.</font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">14. Chaturvedi SK, Abdel-Salam TM, Sreedharan  SS, et al. Two-stage direct expansion solar-assisted heat pump for high  temperature applications. Applied Thermal Engineering. 2009;29(10):2093-9.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">15. Tsatsaronis G, Morosuk T. Understanding and  improving energy conversion systems with the aid of exergy-based methods.  International Journal of Exergy. 2012;11(4):518-42.    </font></p>     ]]></body>
<body><![CDATA[<p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">16. Lazzaretto A, Tsatsaronis G. SPECO: A  systematic and general methodology for calculating efficiencies and costs in  thermal systems. Energy. 2006;31(8&ndash;9):1257-89. </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">17. Meyer L, Tsatsaronis G, Buchgeister J, et  al. Exergoenvironmental analysis for evaluation of the environmental impact of  energy conversion systems. Energy International Journal. 2009;34:75-89.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">18. Tsatsaronis G. Recent developments in exergy  analysis and exergoeconomics. Exergy. 2008;5(5-6):489-99.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">19. Gungor  A, Erbay Z, Hepbasli A, et al. Splitting the exergy destruction into avoidable and unavoidable parts of  a gas engine heat pump (GEHP) for food drying processes based on experimental  values. Energy Conversion and Management. 2013; 73:309-16.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">20. Gungor A, Tsatsaronis G, Gunerhan H, et al.  Advanced exergoeconomic analysis of a gas engine heat pump (GEHP) for food  drying processes. Energy Conversion and Management. 2015; 91:132-139.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">21. Montgomery DC. Design and analysis of  experiments. 8 th ed. 2013. New Jersey, USA: John Wiley &amp; Sons; 2013.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">22. Kush EA. Performance of Heat Pumps at  Elevated Evaporating Temperatures with Applications to Solar Input. Journal of  Solar Energy. 1980;102:203-10.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">23. Chaturvedi SK, Shen JY. Thermal performance  of a direct expansion solar-assisted heat pump. Solar Energy. 1984;  33(2):155-62.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">24. Chaturvedi SK, Chen DT, Kheireddine A.  Thermal performance of a variable capacity direct expansion solar-assisted heat  pump. Energy Conversion and Management. 1998;39(3-4):181-91.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">25. Ito S, Miura N, Wang K. Performance of a  heat pump using direct expansion solar collectors. Solar Energy.  1999;65(3):189-96.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">26. Hawlader MNA, Chou SK, Ullah MZ. The  Performance of Solar Assisted Heat Pump Water Heating System. Applied Thermal  Engineering. 2001;21(10):1049-1065.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">27. Kuang YH, Sumathy K, Wang RZ. Study on a  direct-expansion solar-assisted heat pump water heating system. International  Journal of Energy Research. 2003;27(5):531-48.     </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">28. Soldo V, Curko T, Balem I. Thermal  Performance of a direct expansion solar assisted heat pump In: International  refrigeration and air conditioning conference; Indiana, USA. Purdue  University; 2004. [Citado octubre de 2016] Disponible en: <a href="http://docs.lib.purdue.edu/iracc/724" target="_blank">http://docs.lib.purdue.edu/iracc/724</a>.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">29. Li YW, Wang RZ, Wu JY, et al. Experimental  performance analysis on a direct-expansion solar-assisted heat pump water  heater. Applied Thermal Engineering. 2007;27(17/18):2858-68.     </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">30. Mohanraj M, Jayaraj S, Muraleedharan C.  Performance prediction of a direct expansion solar assisted heat pump using  artificial neural networks. Applied Energy. 2009;86(9):1442-9.    </font></p>     <p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">31. Mohanraj M, Jayaraj S, Muraleedharan C. A  comparison of the performance of a direct expansion solar assisted heat pump  working with R22 and a mixture of R407C&ndash;liquefied petroleum gas. Journal of  Power and Energy. 2009;223(7):821-33.</font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">32. Fern&aacute;ndez-Seara  J, Pi&ntilde;eiro C, Alberto Dopazo J, et al. Experimental analysis of a direct expansion solar  assisted heat pump with integral storage tank for domestic water heating under  zero solar radiation conditions. Energy Conversion and Management. 2012;59:1-8.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">33. Moreno-Rodr&iacute;guez A, Gonz&aacute;lez-Gil A,  Izquierdo M, et al. Theoretical model and experimental validation of a  direct-expansion solar assisted heat pump for domestic hot water applications.  Energy. 2012;45(1):704-15.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">34. Moreno-Rodr&iacute;guez  A, Garc&iacute;a-Hernando N, Gonz&aacute;lez-Gil A, et al. Experimental validation of a theoretical model for a  direct-expansion solar-assisted heat pump applied to heating. Energy.  2013;60:242-53.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">35. Zhu M, Xie H, Zhang B, et al. The  Characteristics of the Evaporator/Evaporator for Direct Expansion Solar Assisted  Heat Pump System. Journal of Power and Energy Engineering. 2013;1:73-6.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">36. Garg R, Kumar A, Kapoor N. An Experimental  Thermal Performance Analysis &amp; Comparison of a Direct Expansion Solar  Assisted Heat Pump Water Heater with Unglazed and Single Glazed Collector.  IJRMET. 2014;4(2):7-10.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">37. Sun  X, Wu J, Dai Y, et al. Experimental  study on roll-bond collector/evaporator with optimized-channel used in direct  expansion solar assisted heat pump water heating system. Applied Thermal  Engineering. 2014;66(1-2):571-9.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">38. Sun X, Dai Y, Novakovic V, et al. Performance  Comparison of Direct Expansion Solar-assisted Heat Pump and Conventional Air  Source Heat Pump for Domestic Hot Water. Energy Procedia. 2015;70:394-401.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">39. Torres-Reyes  E, Pico N&uacute;&ntilde;ez M, Cervantes JG. Exergy analysis and optimization of a solar assisted heat pump. Energy.  1998;23:337-44.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">40. Torres-Reyes E, Cervantes JG. Optimal  performance of an irreversible solar assisted heat pump. Exergy. 2001;1:107-11.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">41. Cervantes JG, Torres-Reyes E. Experiments on  a solar-assisted heat pump and an exergy analysis of the system. Applied  Thermal Engineering. 2002;22:1289-97.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">42. Li YW, Wang RZ, Wu JY, et al. Experimental  performance analysis and optimization of a direct expansion solar-assisted heat  pump water heater. Energy. 2007;32(8):1361-74.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">43. Kara O, Ulgen K, Hepbasli A. Exergetic  assessment of direct-expansion solar-assisted heat pump systems: Review and  modeling. Renewable and Sustainable Energy Reviews. 2008;12(5):1383-401.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">44. Mohanraj M, Jayaraj S, Muraleedharan C.  Exergy analysis of direct expansion solar-assisted heat pumps using artificial  neural networks. International Journal of Energy Research. 2009;33(11):1005-20.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">45. Mohanraj M, Jayaraj S, Muraleedharan C.  Exergy Assessment of a Direct Expansion Solar-Assisted Heat Pump Working with  R22 and R407C/LPG Mixture. International Journal of Green Energy.  2010;7(1):65-83.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">46. Yousefi M, Moradali M. Thermodynamic  analysis of a direct expansion solar assisted heat pump water heater. Journal  of Energy in Southern Africa. 2015;26:110-7.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">47. Kumar KV, Paradeshi L, Srinivas M, et al. Parametric  Studies of a Simple Direct Expansion Solar Assisted Heat Pump Using ANN and GA.  Energy Procedia. 2016, 90:625-34.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">48. Paradeshi L, Srinivas M, Jayaraj S.  Parametric Studies of a Simple Direct Expansion Solar Assisted Heat Pump  Operating in a Hot and Humid Environment. Energy Procedia. 2016, 90:635-44.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">49. Malali PD, Chaturvedi SK, Abdel-Salam TM. An  approximate method for prediction of thermal performance of direct  expansion-solar assisted heat pump (DX-SAHP) systems for water heating  applications. Energy Conversion and Management. 2016,127:416-23.    </font></p>     <!-- ref --><p align="justify" style="text-autospace:none;"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">50. Holman  JP. Experimental methods for engineers 8th ed. New York, USA: Mc Graw Hill;  2012.     </font></p>     <p align="justify" class="Fechas">&nbsp;</p>     <p align="justify" class="Fechas">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify" class="Fechas"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Recibido:  24/3/2017</font></p>     <p align="justify" class="Fechas"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; ">Aceptado:  12/7/2017</font></p>     <p align="justify" class="Autor">&nbsp;</p>     <p align="justify" class="Autor">&nbsp;</p>     <p align="justify" class="Autor"><font style="font-family:'Verdana','sans-serif'; font-size:10.0pt; "><i>Francis B.  Gorozabel-Chata</i>, Universidad T&eacute;cnica de Manab&iacute;. Departamento de Ingenier&iacute;a  Mec&aacute;nica.Portoviejo, Ecuador. Correo electr&oacute;nico: <a href="mailto:fgorozabel@utm.edu.ec">fgorozabel@utm.edu.ec</a> &nbsp;</font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Omojaro]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Breitkopf]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Direct expansion solar assisted heat pumps: A review of applications and recent research]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2013</year>
<volume>22</volume>
<page-range>33-45</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chaturvedi]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Gagrani]]></surname>
<given-names><![CDATA[VD]]></given-names>
</name>
<name>
<surname><![CDATA[Abdel-Salam]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Solar-assisted heat pump - A sustainable system for low-temperature water heating applications]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>2014</year>
<volume>77</volume>
<page-range>550-7</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<collab>Gorozabel-Chata F-B.Carbonell-Morales T</collab>
<article-title xml:lang="pt"><![CDATA[Actualidad y perspectivas de una bomba de calor de expansión directa con energía solar]]></article-title>
<source><![CDATA[Ingeniería Mecánica]]></source>
<year>2016</year>
<volume>19</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>49-58</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Raisul Islam]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Sumathy]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Ullah Khan]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Solar water heating systems and their market trends]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2013</year>
<volume>17</volume>
<page-range>1-25</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Buker Mahmut]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Riffat]]></surname>
<given-names><![CDATA[SB]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Solar assisted heat pump systems for low temperature water heating applications: A systematic review]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2016</year>
<volume>3</volume>
<numero>55</numero>
<issue>55</issue>
<page-range>399-413</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amin]]></surname>
<given-names><![CDATA[ZM]]></given-names>
</name>
<name>
<surname><![CDATA[Hawlader]]></surname>
<given-names><![CDATA[MNA]]></given-names>
</name>
<name>
<surname><![CDATA[Shaochum]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis and Modeling of Solar Evaporator-Collector]]></article-title>
<source><![CDATA[IIUM Engineering]]></source>
<year>2015</year>
<volume>16</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>13-29</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gorozabel Chata]]></surname>
<given-names><![CDATA[FB]]></given-names>
</name>
<name>
<surname><![CDATA[Carbonell Morales]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Análisis del Coeficiente de Desempeño de una Bomba de Calor de Expansión Directa con Energía Solar]]></article-title>
<source><![CDATA[]]></source>
<year>2016</year>
<conf-name><![CDATA[XVIII Convención Científica de Ingeniería y Arquitectura]]></conf-name>
<conf-loc>La Habana La Habana</conf-loc>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Molinaroli]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Joppolo]]></surname>
<given-names><![CDATA[CM]]></given-names>
</name>
<name>
<surname><![CDATA[De Antonellis]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Numerical Analysis of the Use of R-407C in Direct Expansion Solar Assisted Heat Pump]]></article-title>
<source><![CDATA[Energy Procedia]]></source>
<year>2014</year>
<volume>48</volume>
<page-range>938-45</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kong]]></surname>
<given-names><![CDATA[XQ]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Lin]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Modeling evaluation of a direct-expansion solar-assisted heat pump water heater using R410A]]></article-title>
<source><![CDATA[International Journal of Refrigeration]]></source>
<year>2017</year>
<volume>76</volume>
<page-range>136-146</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Amin]]></surname>
<given-names><![CDATA[ZM]]></given-names>
</name>
<name>
<surname><![CDATA[Hawlader]]></surname>
<given-names><![CDATA[MNA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Analysis of solar desalination system using heat pump]]></article-title>
<source><![CDATA[Renewable Energy]]></source>
<year>2015</year>
<volume>74</volume>
<page-range>116-23</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Starke]]></surname>
<given-names><![CDATA[AR]]></given-names>
</name>
<name>
<surname><![CDATA[Cardemil]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[Escobar]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thermal analysis of solar-assisted heat pumps for swimming pool heating]]></article-title>
<source><![CDATA[Journal of the Brazilian Society of Mechanical Sciences and Engineering]]></source>
<year>2017</year>
<volume>39</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>2289-2306</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Scarpa]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Tagliafico]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Bianco]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A novel steady-state approach for the analysis of gas-burner supplemented direct expansion solar assisted heat pumps]]></article-title>
<source><![CDATA[Solar Energy]]></source>
<year>2013</year>
<volume>96</volume>
<page-range>227-238</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tagliafico]]></surname>
<given-names><![CDATA[LA]]></given-names>
</name>
<name>
<surname><![CDATA[Scarpa]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Valsuani]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Direct expansion solar assisted heat pumps - A clean steady state approach for overall performance analysis]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2014</year>
<volume>66</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>216-26</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chaturvedi]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Abdel-Salam]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
<name>
<surname><![CDATA[Sreedharan]]></surname>
<given-names><![CDATA[SS]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Two-stage direct expansion solar-assisted heat pump for high temperature applications]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2009</year>
<volume>29</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>2093-9</page-range></nlm-citation>
</ref>
<ref id="B15">
<label>15</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tsatsaronis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Morosuk]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Understanding and improving energy conversion systems with the aid of exergy-based methods]]></article-title>
<source><![CDATA[International Journal of Exergy]]></source>
<year>2012</year>
<volume>11</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>518-42</page-range></nlm-citation>
</ref>
<ref id="B16">
<label>16</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lazzaretto]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Tsatsaronis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[SPECO: A systematic and general methodology for calculating efficiencies and costs in thermal systems]]></article-title>
<source><![CDATA[Energy]]></source>
<year>2006</year>
<volume>31</volume>
<numero>8-9</numero>
<issue>8-9</issue>
<page-range>1257-89</page-range></nlm-citation>
</ref>
<ref id="B17">
<label>17</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Meyer]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Tsatsaronis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Buchgeister]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Exergoenvironmental analysis for evaluation of the environmental impact of energy conversion systems]]></article-title>
<source><![CDATA[Energy International Journal]]></source>
<year>2009</year>
<volume>34</volume>
<page-range>75-89</page-range></nlm-citation>
</ref>
<ref id="B18">
<label>18</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Tsatsaronis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Recent developments in exergy analysis and exergoeconomics]]></article-title>
<source><![CDATA[Exergy]]></source>
<year>2008</year>
<volume>5</volume>
<numero>5-6</numero>
<issue>5-6</issue>
<page-range>489-99</page-range></nlm-citation>
</ref>
<ref id="B19">
<label>19</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gungor]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Erbay]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
<name>
<surname><![CDATA[Hepbasli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Splitting the exergy destruction into avoidable and unavoidable parts of a gas engine heat pump (GEHP) for food drying processes based on experimental values]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>2013</year>
<volume>73</volume>
<page-range>309-16</page-range></nlm-citation>
</ref>
<ref id="B20">
<label>20</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gungor]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Tsatsaronis]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Gunerhan]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Advanced exergoeconomic analysis of a gas engine heat pump (GEHP) for food drying processes]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>2015</year>
<volume>91</volume>
<page-range>132-139</page-range></nlm-citation>
</ref>
<ref id="B21">
<label>21</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Montgomery]]></surname>
<given-names><![CDATA[DC]]></given-names>
</name>
</person-group>
<source><![CDATA[Design and analysis of experiments]]></source>
<year>2013</year>
<month>20</month>
<day>13</day>
<edition>8</edition>
<publisher-loc><![CDATA[^eNew Jersey New Jersey]]></publisher-loc>
<publisher-name><![CDATA[John Wiley & Sons]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B22">
<label>22</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kush]]></surname>
<given-names><![CDATA[EA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Performance of Heat Pumps at Elevated Evaporating Temperatures with Applications to Solar Input]]></article-title>
<source><![CDATA[Journal of Solar Energy]]></source>
<year>1980</year>
<volume>102</volume>
<page-range>203-10</page-range></nlm-citation>
</ref>
<ref id="B23">
<label>23</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chaturvedi]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Shen]]></surname>
<given-names><![CDATA[JY]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thermal performance of a direct expansion solar-assisted heat pump]]></article-title>
<source><![CDATA[Solar Energy]]></source>
<year>1984</year>
<volume>33</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>155-62</page-range></nlm-citation>
</ref>
<ref id="B24">
<label>24</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chaturvedi]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[DT]]></given-names>
</name>
<name>
<surname><![CDATA[Kheireddine]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thermal performance of a variable capacity direct expansion solar-assisted heat pump]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>1998</year>
<volume>39</volume>
<numero>3-4</numero>
<issue>3-4</issue>
<page-range>181-91</page-range></nlm-citation>
</ref>
<ref id="B25">
<label>25</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ito]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Miura]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Performance of a heat pump using direct expansion solar collectors]]></article-title>
<source><![CDATA[Solar Energy]]></source>
<year>1999</year>
<volume>65</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>189-96</page-range></nlm-citation>
</ref>
<ref id="B26">
<label>26</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hawlader]]></surname>
<given-names><![CDATA[MNA]]></given-names>
</name>
<name>
<surname><![CDATA[Chou]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Ullah]]></surname>
<given-names><![CDATA[MZ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Performance of Solar Assisted Heat Pump Water Heating System]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2001</year>
<volume>21</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1049-1065</page-range></nlm-citation>
</ref>
<ref id="B27">
<label>27</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kuang]]></surname>
<given-names><![CDATA[YH]]></given-names>
</name>
<name>
<surname><![CDATA[Sumathy]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[RZ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Study on a direct-expansion solar-assisted heat pump water heating system]]></article-title>
<source><![CDATA[International Journal of Energy Research]]></source>
<year>2003</year>
<volume>27</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>531-48</page-range></nlm-citation>
</ref>
<ref id="B28">
<label>28</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Soldo]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
<name>
<surname><![CDATA[Curko]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Balem]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thermal Performance of a direct expansion solar assisted heat pump]]></article-title>
<source><![CDATA[]]></source>
<year>2004</year>
<conf-name><![CDATA[ International refrigeration and air conditioning conference]]></conf-name>
<conf-loc>Indiana Indiana</conf-loc>
</nlm-citation>
</ref>
<ref id="B29">
<label>29</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[YW]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[RZ]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[JY]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Experimental performance analysis on a direct-expansion solar-assisted heat pump water heater]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2007</year>
<volume>27</volume>
<numero>17/18</numero>
<issue>17/18</issue>
<page-range>2858-68</page-range></nlm-citation>
</ref>
<ref id="B30">
<label>30</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mohanraj]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jayaraj]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Muraleedharan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Performance prediction of a direct expansion solar assisted heat pump using artificial neural networks]]></article-title>
<source><![CDATA[Applied Energy]]></source>
<year>2009</year>
<volume>86</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1442-9</page-range></nlm-citation>
</ref>
<ref id="B31">
<label>31</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mohanraj]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jayaraj]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Muraleedharan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A comparison of the performance of a direct expansion solar assisted heat pump working with R22 and a mixture of R407C-liquefied petroleum gas]]></article-title>
<source><![CDATA[Journal of Power and Energy]]></source>
<year>2009</year>
<volume>223</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>821-33</page-range></nlm-citation>
</ref>
<ref id="B32">
<label>32</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernández-Seara]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Piñeiro]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Alberto Dopazo]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Experimental analysis of a direct expansion solar assisted heat pump with integral storage tank for domestic water heating under zero solar radiation conditions]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>2012</year>
<volume>59</volume>
<page-range>1-8</page-range></nlm-citation>
</ref>
<ref id="B33">
<label>33</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moreno-Rodríguez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[González-Gil]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Izquierdo]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Theoretical model and experimental validation of a direct-expansion solar assisted heat pump for domestic hot water applications]]></article-title>
<source><![CDATA[Energy]]></source>
<year>2012</year>
<volume>45</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>704-15</page-range></nlm-citation>
</ref>
<ref id="B34">
<label>34</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moreno-Rodríguez]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[García-Hernando]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[González-Gil]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Experimental validation of a theoretical model for a direct-expansion solar-assisted heat pump applied to heating]]></article-title>
<source><![CDATA[Energy]]></source>
<year>2013</year>
<volume>60</volume>
<page-range>242-53</page-range></nlm-citation>
</ref>
<ref id="B35">
<label>35</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhu]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Xie]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Characteristics of the Evaporator/Evaporator for Direct Expansion Solar Assisted Heat Pump System]]></article-title>
<source><![CDATA[Journal of Power and Energy Engineering]]></source>
<year>2013</year>
<volume>1</volume>
<page-range>73-6</page-range></nlm-citation>
</ref>
<ref id="B36">
<label>36</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Garg]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Kumar]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Kapoor]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An Experimental Thermal Performance Analysis & Comparison of a Direct Expansion Solar Assisted Heat Pump Water Heater with Unglazed and Single Glazed Collector]]></article-title>
<source><![CDATA[IJRMET]]></source>
<year>2014</year>
<volume>4</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>7-10</page-range></nlm-citation>
</ref>
<ref id="B37">
<label>37</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sun]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Dai]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Experimental study on roll-bond collector/evaporator with optimized-channel used in direct expansion solar assisted heat pump water heating system]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2014</year>
<volume>66</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>571-9</page-range></nlm-citation>
</ref>
<ref id="B38">
<label>38</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sun]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
<name>
<surname><![CDATA[Dai]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Novakovic]]></surname>
<given-names><![CDATA[V]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Performance Comparison of Direct Expansion Solar-assisted Heat Pump and Conventional Air Source Heat Pump for Domestic Hot Water]]></article-title>
<source><![CDATA[Energy Procedia]]></source>
<year>2015</year>
<volume>70</volume>
<page-range>394-401</page-range></nlm-citation>
</ref>
<ref id="B39">
<label>39</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torres-Reyes]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Pico Núñez]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Cervantes]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Exergy analysis and optimization of a solar assisted heat pump]]></article-title>
<source><![CDATA[Energy]]></source>
<year>1998</year>
<volume>23</volume>
<page-range>337-44</page-range></nlm-citation>
</ref>
<ref id="B40">
<label>40</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Torres-Reyes]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Cervantes]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Optimal performance of an irreversible solar assisted heat pump]]></article-title>
<source><![CDATA[Exergy]]></source>
<year>2001</year>
<volume>1</volume>
<page-range>107-11</page-range></nlm-citation>
</ref>
<ref id="B41">
<label>41</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cervantes]]></surname>
<given-names><![CDATA[JG]]></given-names>
</name>
<name>
<surname><![CDATA[Torres-Reyes]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Experiments on a solar-assisted heat pump and an exergy analysis of the system]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2002</year>
<volume>22</volume>
<page-range>1289-97</page-range></nlm-citation>
</ref>
<ref id="B42">
<label>42</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[YW]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[RZ]]></given-names>
</name>
<name>
<surname><![CDATA[Wu]]></surname>
<given-names><![CDATA[JY]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Experimental performance analysis and optimization of a direct expansion solar-assisted heat pump water heater]]></article-title>
<source><![CDATA[Energy]]></source>
<year>2007</year>
<volume>32</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>1361-74</page-range></nlm-citation>
</ref>
<ref id="B43">
<label>43</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kara]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Ulgen]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Hepbasli]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Exergetic assessment of direct-expansion solar-assisted heat pump systems: Review and modeling]]></article-title>
<source><![CDATA[Renewable and Sustainable Energy Reviews]]></source>
<year>2008</year>
<volume>12</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>1383-401</page-range></nlm-citation>
</ref>
<ref id="B44">
<label>44</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mohanraj]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jayaraj]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Muraleedharan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Exergy analysis of direct expansion solar-assisted heat pumps using artificial neural networks]]></article-title>
<source><![CDATA[International Journal of Energy Research]]></source>
<year>2009</year>
<volume>33</volume>
<numero>11</numero>
<issue>11</issue>
<page-range>1005-20</page-range></nlm-citation>
</ref>
<ref id="B45">
<label>45</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mohanraj]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jayaraj]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Muraleedharan]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Exergy Assessment of a Direct Expansion Solar-Assisted Heat Pump Working with R22 and R407C/LPG Mixture]]></article-title>
<source><![CDATA[International Journal of Green Energy]]></source>
<year>2010</year>
<volume>7</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>65-83</page-range></nlm-citation>
</ref>
<ref id="B46">
<label>46</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yousefi]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Moradali]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Thermodynamic analysis of a direct expansion solar assisted heat pump water heater]]></article-title>
<source><![CDATA[Journal of Energy in Southern Africa]]></source>
<year>2015</year>
<volume>26</volume>
<page-range>110-7</page-range></nlm-citation>
</ref>
<ref id="B47">
<label>47</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kumar]]></surname>
<given-names><![CDATA[KV]]></given-names>
</name>
<name>
<surname><![CDATA[Paradeshi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Srinivas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Parametric Studies of a Simple Direct Expansion Solar Assisted Heat Pump Using ANN and GA]]></article-title>
<source><![CDATA[Energy Procedia]]></source>
<year>2016</year>
<volume>90</volume>
<page-range>625-34</page-range></nlm-citation>
</ref>
<ref id="B48">
<label>48</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Paradeshi]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Srinivas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Jayaraj]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Parametric Studies of a Simple Direct Expansion Solar Assisted Heat Pump Operating in a Hot and Humid Environment]]></article-title>
<source><![CDATA[Energy Procedia]]></source>
<year>2016</year>
<volume>90</volume>
<page-range>635-44</page-range></nlm-citation>
</ref>
<ref id="B49">
<label>49</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Malali]]></surname>
<given-names><![CDATA[PD]]></given-names>
</name>
<name>
<surname><![CDATA[Chaturvedi]]></surname>
<given-names><![CDATA[SK]]></given-names>
</name>
<name>
<surname><![CDATA[Abdel-Salam]]></surname>
<given-names><![CDATA[TM]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[An approximate method for prediction of thermal performance of direct expansion-solar assisted heat pump (DX-SAHP) systems for water heating applications]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>2016</year>
<volume>127</volume>
<page-range>416-23</page-range></nlm-citation>
</ref>
<ref id="B50">
<label>50</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Holman]]></surname>
<given-names><![CDATA[JP]]></given-names>
</name>
</person-group>
<source><![CDATA[Experimental methods for engineers]]></source>
<year>2012</year>
<edition>8</edition>
<publisher-loc><![CDATA[USA ]]></publisher-loc>
<publisher-name><![CDATA[Mc Graw Hill]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>