<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2223-4861</journal-id>
<journal-title><![CDATA[Centro Azúcar]]></journal-title>
<abbrev-journal-title><![CDATA[cen. az.]]></abbrev-journal-title>
<issn>2223-4861</issn>
<publisher>
<publisher-name><![CDATA[Editorial Feijóo]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2223-48612019000200021</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[EMPLEO DE CONDENSADORES SECOS EN CENTRALES TERMOELÉCTRICAS DE BIOMASA: UN CASO DE ESTUDIO]]></article-title>
<article-title xml:lang="en"><![CDATA[USES OF AIR COOLED CONDENSER IN THERMOELECTRIC POWER PLANT OF BIOMASS: AN STUDY CASE]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Camaraza Medina]]></surname>
<given-names><![CDATA[Yanán]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández Guerrero]]></surname>
<given-names><![CDATA[Abel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Luviano Ortiz]]></surname>
<given-names><![CDATA[José Luis]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cruz Fonticiella]]></surname>
<given-names><![CDATA[Oscar Miguel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García Morales]]></surname>
<given-names><![CDATA[Osvaldo Fidel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad de Matanzas Facultad de Ciencias Técnicas ]]></institution>
<addr-line><![CDATA[Varadero Matanzas]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad de Guanajuato Departamento de Ingeniería Mecánica ]]></institution>
<addr-line><![CDATA[ Guanajuato]]></addr-line>
<country>Mexico</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidad Central &#8220;Marta Abreu&#8221; de las Villas Facultad de Ingeniería Mecánica e Industrial Centro de Estudios Energéticos y Tecnologías Ambientales (CEETA)]]></institution>
<addr-line><![CDATA[Santa Clara Villa Clara]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2019</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2019</year>
</pub-date>
<volume>46</volume>
<numero>2</numero>
<fpage>21</fpage>
<lpage>34</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S2223-48612019000200021&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S2223-48612019000200021&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S2223-48612019000200021&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN El proyecto inversionista de 25 centrales termoeléctricas (CTE) de biomasa en Cuba con potencias de 20 y 50 MW, así como la carencia probada de agua para sus sistemas de enfriamiento, apuntan al posible empleo de sistemas de condensadores secos (ACC) en dichas plantas, sin embargo el encarecimiento del proyecto inicial y la reducción de potencia útil asociada su empleo es una limitante a considerar. Para definir la factibilidad del empleo de ACC en estos proyectos se realiza un estudio de caso en el cual son considerados varios criterios de selección para alternativas de inversión, siendo evaluados adicionalmente otros tres tipos de tecnologías de condensación con el objetivo de establecer comparación de costos de inversión y operación, así como de las utilidades generadas. En todos los casos los análisis fueron efectuados para un horizonte de 20 años. Los resultados obtenidos confirman la factibilidad del empleo de sistemas ACC, con un período de recuperación compuesto de la inversión de 7,6 a los 8,4 años, la Tasa de Interés de Retorno (TIR) computa valores entre el 18,2 a 23,8 por ciento, el Valor Actual Neto (VAN) con una tasa de actualización del 15% alcanza valores entre los 1 126,9 a 3 024,0 MUSD, el costo del ciclo de vida se ubica entre los 10 682,4 a 24 406,1 MUSD, mientras que el costo nivelado de la energía fluctúa entre los 0,062 a 0,071 USD/kWh, con una relación costo beneficio entre 0,1 a 0,13.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT The investment project of 25 thermoelectric plants (CTE) of biomass in Cuba with powers of 20 and 50 MW, as well as the proven lack of water for their cooling systems, point to the possible use of dry capacitor systems (ACC) in these plants. However, the increase in the initial project cost and the reduction in useful power associated with its use is a limitation to consider. To define the feasibility of ACC use in these projects, a case study is carried out in which several selection criteria for investment alternatives are considered. Also three other types of condensation technologies are evaluated in order to establish the investment and operation cost comparison, as well as the profits generated. In all cases, these analyzes were carried out for a 20-year horizon. The results obtained confirm the feasibility of using ACC systems, with a composed investment recovery period from 7.6 to 8.4 years, the IRR computes values between 18.2 to 23.8 percent. The NPV with an update rate of 15% reaches values between 10682.4 and 3 024 MUSD, Life cycle cost is between 10 682.4 and 24 406.1 MUSD. Level cost of energy fluctuates between 0.062 to 0.071 USD / kWh, with a cost-benefit ratio between 0.1 to 0.13.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[costo ciclo de vida]]></kwd>
<kwd lng="es"><![CDATA[costo nivelado]]></kwd>
<kwd lng="es"><![CDATA[industria azucarera]]></kwd>
<kwd lng="es"><![CDATA[planta de potencia]]></kwd>
<kwd lng="en"><![CDATA[life cycle cost]]></kwd>
<kwd lng="en"><![CDATA[level cost]]></kwd>
<kwd lng="en"><![CDATA[sugar industry]]></kwd>
<kwd lng="en"><![CDATA[power plant]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bilgili]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Kocak]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Bulut]]></surname>
<given-names><![CDATA[U.]]></given-names>
</name>
<name>
<surname><![CDATA[Kuskaya]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[¿Can biomass energy be an efficient policy tool for sustainable development?]]></article-title>
<source><![CDATA[Renewable and sustainable Energy Reviews]]></source>
<year>2016</year>
<volume>18</volume>
<numero>70</numero>
<issue>70</issue>
<page-range>832-49</page-range></nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Blanco-Marigorta]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Moser]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Trieb]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
<name>
<surname><![CDATA[Fitcher]]></surname>
<given-names><![CDATA[T.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Techo-economic analysis of dry cooling for CSP]]></article-title>
<source><![CDATA[Energy Procedia]]></source>
<year>2013</year>
<volume>49</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>1177-86</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bustamante]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Rattner]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Garimella]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Reducing the performance penalty of air-cooled condensers in power plants]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2017</year>
<volume>107</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>5-65</page-range></nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Camaraza]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
</person-group>
<source><![CDATA[Introducción a la termo transferencia]]></source>
<year>2017</year>
<page-range>515-35</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Universitaria]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Camaraza]]></surname>
<given-names><![CDATA[Y.]]></given-names>
</name>
<name>
<surname><![CDATA[Fonticiella]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[O.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Predicción de la presión de salida de una turbina acoplada a un condensador de vapor refrigerado por aire]]></article-title>
<source><![CDATA[Centro Azúcar]]></source>
<year>2018</year>
<volume>45</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>50-61</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chen]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Yang]]></surname>
<given-names><![CDATA[L.]]></given-names>
</name>
<name>
<surname><![CDATA[Du]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A novel layout of air-cooled condensers to improve thermo-flow performances]]></article-title>
<source><![CDATA[Applied Energy]]></source>
<year>2016</year>
<volume>165</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>246-51</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="book">
<source><![CDATA[Reglamento del proceso inversionista]]></source>
<year>2015</year>
<page-range>1-24</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Consejo de Ministros]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="">
<collab>(DOE) Department of Energy</collab>
<source><![CDATA[A rapid guide to perform Life Cycle Cost]]></source>
<year>2017</year>
<page-range>1-10</page-range><publisher-loc><![CDATA[Washington ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="book">
<collab>DNC</collab>
<source><![CDATA[Resumen operación de la red año 2016]]></source>
<year>2017</year>
<page-range>2-3</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[UNE]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="book">
<collab>ECIAZ</collab>
<source><![CDATA[Datos técnicos e ingeniería básica para el proyecto de instalación de CTE de biomasa quinquenio 2017-2022]]></source>
<year>2017</year>
<page-range>1-87</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[ECIAZ, SA.]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fahmy]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Nabih]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Impact of ambient temperature and heat load variation on the performance of air cooled heat exchangers]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>2016</year>
<volume>121</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>22-35</page-range></nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Feng]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Ping]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
<name>
<surname><![CDATA[Quing]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
<name>
<surname><![CDATA[Zhong]]></surname>
<given-names><![CDATA[Q.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Influence mechanism on flow and heat transfer characteristics for air-cooled steam condenser cells]]></article-title>
<source><![CDATA[Heat and Mass Transfer]]></source>
<year>2012</year>
<volume>48</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>1663-74</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Guang]]></surname>
<given-names><![CDATA[X.]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[H.]]></given-names>
</name>
<name>
<surname><![CDATA[Yao]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
<name>
<surname><![CDATA[Marechal]]></surname>
<given-names><![CDATA[F.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Thermo-economic optimization of a combined cooling and power system based on small-scale compressed air energy storage]]></article-title>
<source><![CDATA[Energy Conversion and Management]]></source>
<year>2017</year>
<volume>118</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>377-86</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Heyns]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Performance Characteristics of an Air-Cooled Steam Condenser with a Hybrid Dephlegmator]]></article-title>
<source><![CDATA[Journal of the South African Institution of Mechanical Engineering]]></source>
<year>2012</year>
<volume>28</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>31-6</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="book">
<collab>HOLTEC INTERNATIONAL</collab>
<source><![CDATA[Budgetary proposal for engineer Yanán Camaraza]]></source>
<year>2017</year>
<page-range>1-36</page-range><publisher-name><![CDATA[Universidad Central de Las Villas]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="">
<collab>IDEA</collab>
<source><![CDATA[World Energy Resources 2016]]></source>
<year>2016</year>
<page-range>16-7</page-range><publisher-loc><![CDATA[Oklahoma ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="book">
<collab>INRH</collab>
<source><![CDATA[Boletín de Análisis de lluvias, embalses, acuíferos y costo del agua]]></source>
<year>2017</year>
<page-range>130-8</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
<publisher-name><![CDATA[Dirección de Uso Racional del Agua, INRH]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kaplan]]></surname>
<given-names><![CDATA[S.]]></given-names>
</name>
</person-group>
<source><![CDATA[Power plant characteristics and cost analysis]]></source>
<year>2011</year>
<edition>1st edition</edition>
<page-range>338-99</page-range><publisher-loc><![CDATA[Washington ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Nova, Library of United States Congress]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kröger]]></surname>
<given-names><![CDATA[D.]]></given-names>
</name>
</person-group>
<source><![CDATA[Air-cooled heat exchanger and cooling tower]]></source>
<year>2012</year>
<page-range>383-414</page-range><publisher-loc><![CDATA[Oklahoma ]]></publisher-loc>
<publisher-name><![CDATA[PennWell Corporation]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kumar]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Joshi]]></surname>
<given-names><![CDATA[J.]]></given-names>
</name>
<name>
<surname><![CDATA[Nayak]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Vijayan]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A complete review on the thermal hydraulic characteristics of the air-cooled condenser in forced convection]]></article-title>
<source><![CDATA[Sadhana]]></source>
<year>2015</year>
<volume>40</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>513-755</page-range></nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Lam]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Law]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Crowd funding for renewable and sustainable energy projects: An exploratory case study approach]]></article-title>
<source><![CDATA[Renewable and sustainable Energy Reviews]]></source>
<year>2016</year>
<volume>60</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>11-20</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mishra]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Arya]]></surname>
<given-names><![CDATA[M.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A review of literature on air cooled steam condenser]]></article-title>
<source><![CDATA[International Journal of Research in Engineering]]></source>
<year>2015</year>
<volume>3</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1-12</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Mortensen]]></surname>
<given-names><![CDATA[K.]]></given-names>
</name>
</person-group>
<source><![CDATA[Improved performance of an air cooled condenser using SPX wind guide technology]]></source>
<year>2013</year>
<page-range>28-52</page-range><publisher-name><![CDATA[SPX]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[O&#8217;Donovan]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Grimes]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[A theoretical and experimental investigation into the thermodynamic performance of an power plant with a novel modular air-cooled condenser]]></article-title>
<source><![CDATA[Applied Thermal Engineering]]></source>
<year>2014</year>
<volume>71</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>119-29</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[O&#8217;Donovan]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The influence of the steam-side characteristics of a modular air-cooled condenser]]></article-title>
<source><![CDATA[Energy Procedia]]></source>
<year>2017</year>
<volume>49</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>1450-9</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="">
<collab>ONEI, Oficina Nacional de Estadística e Información</collab>
<source><![CDATA[Anuario Estadístico 2016]]></source>
<year>2017</year>
<page-range>149-52</page-range><publisher-loc><![CDATA[La Habana ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Román]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Análisis metodológico para la evaluación y comparación de tecnologías en la generación eléctrica]]></article-title>
<source><![CDATA[CELAC]]></source>
<year>2017</year>
<volume>4</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>27-39</page-range><publisher-loc><![CDATA[Santiago de Chile ]]></publisher-loc>
<publisher-name><![CDATA[Natural Resources Defense Council]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B28">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Sabol]]></surname>
<given-names><![CDATA[E.]]></given-names>
</name>
</person-group>
<source><![CDATA[Case studies in mechanical engineering: Decision making, fluid mechanics and heat transfer]]></source>
<year>2016</year>
<edition>1st edition</edition>
<page-range>111-39</page-range><publisher-loc><![CDATA[Liverpool ]]></publisher-loc>
<publisher-name><![CDATA[John Wiley &amp; Sons]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B29">
<nlm-citation citation-type="book">
<collab>WER</collab>
<source><![CDATA[World Energy Resources 2016]]></source>
<year>2017</year>
<page-range>12-23</page-range><publisher-loc><![CDATA[Bruselas ]]></publisher-loc>
<publisher-name><![CDATA[World Energy Council]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B30">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zweifel]]></surname>
<given-names><![CDATA[P.]]></given-names>
</name>
<name>
<surname><![CDATA[Praktiknjo]]></surname>
<given-names><![CDATA[A.]]></given-names>
</name>
<name>
<surname><![CDATA[Erdmann]]></surname>
<given-names><![CDATA[G.]]></given-names>
</name>
</person-group>
<source><![CDATA[Energy economics in power plants, Theory and applications]]></source>
<year>2017</year>
<edition>1st edition</edition>
<page-range>234-9</page-range><publisher-loc><![CDATA[Berlin ]]></publisher-loc>
<publisher-name><![CDATA[Springer]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>
