<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2224-5421</journal-id>
<journal-title><![CDATA[Revista Cubana de Química]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cub Quim]]></abbrev-journal-title>
<issn>2224-5421</issn>
<publisher>
<publisher-name><![CDATA[Ediciones UO, Universidad de Oriente]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2224-54212014000200005</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Diseño, construcción y caracterización de titulaciones microcoulombimétricas ácido-base con monitoreo visual y micropotencimétrico: Aproximación metrológica]]></article-title>
<article-title xml:lang="en"><![CDATA[Low Cost Microcoulometry Titration System: Metrology Approach]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Marín-Medina]]></surname>
<given-names><![CDATA[Alejandro]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García-Mendoza]]></surname>
<given-names><![CDATA[Arturo]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Santiago-Zarate]]></surname>
<given-names><![CDATA[Adrián]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Baeza-Reyes]]></surname>
<given-names><![CDATA[Alejandro]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Ciudad Universitaria Facultad de Química ]]></institution>
<addr-line><![CDATA[D.F ]]></addr-line>
<country>México</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>08</month>
<year>2014</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>08</month>
<year>2014</year>
</pub-date>
<volume>26</volume>
<numero>2</numero>
<fpage>126</fpage>
<lpage>136</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S2224-54212014000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S2224-54212014000200005&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S2224-54212014000200005&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se construyó un microcoulombímetro de mínima instrumentación MIMCoul con materiales locales de bajo costo. Se realizó la titulación microcoulombimétrica de disoluciones estandarizadas de HCl deciformales con indicación visual del tiempo asociado al punto de equivalencia experimental. Se monitoreó el punto de equivalencia potenciométricamente con microelectrodos para pH y de referencia construidos en el laboratorio. Se compararon las incertidumbres asociadas a la microtitulación propuesta con respecto a la determinación en condiciones titulométricas convencionales.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Low cost equipment with locally materials to perform microcoulometric acid-base titrations with micropotentiometric endpoint detection were developed. Visual detection was also assayed. Statistical analysis was performed comparing results obtained with standard methods as well to evaluate the minimal instrumentation micro coulometer MIMCoul , performance.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[microcoulombimetría]]></kwd>
<kwd lng="es"><![CDATA[micropotenciometría]]></kwd>
<kwd lng="es"><![CDATA[metrología]]></kwd>
<kwd lng="en"><![CDATA[microISE]]></kwd>
<kwd lng="en"><![CDATA[microcoulometry]]></kwd>
<kwd lng="en"><![CDATA[metrology]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font face="Verdana" size="2"><b>ARTICULOS</b></font></p>     <p align="right">&nbsp;</p>     <p align="justify"><b><font size="4" face="Verdana">Dise&ntilde;o, construcci&oacute;n y caracterizaci&oacute;n de titulaciones microcoulombim&eacute;tricas &aacute;cido-base con monitoreo visual y micropotencim&eacute;trico: Aproximaci&oacute;n metrol&oacute;gica</font></b></p>     <p align="justify">&nbsp; </p>     <p align="justify"><b><font size="3" face="Verdana">Low Cost Microcoulometry Titration System: Metrology Approach </font></b></p>     <p align="justify">&nbsp;</p>     <p align="justify">&nbsp; </p>     <p align="justify"><font size="2" face="Verdana"><b>Lic. Alejandro Mar&iacute;n-Medina, Dr. Arturo Garc&iacute;a-Mendoza, MSc. Adri&aacute;n de Santiago-Zarate, Dr. Alejandro Baeza-Reyes </b></font></p>     <p align="justify"><font size="2" face="Verdana">Facultad de Qu&iacute;mica, Ciudad Universitaria, D.F., M&eacute;xico, <a href="mailto:baeza@unam.mx">baeza@unam.mx </a></font></p>     <p align="justify">&nbsp;</p>     ]]></body>
<body><![CDATA[<p align="justify">&nbsp;</p> <hr>     <p align="justify"><font size="2" face="Verdana"><b>RESUMEN</b></font></p>     <p align="justify"><font size="2" face="Verdana">Se construy&oacute; un microcoulomb&iacute;metro de m&iacute;nima instrumentaci&oacute;n <i>MIMCoul </i> con materiales locales de bajo costo. Se realiz&oacute; la titulaci&oacute;n microcoulombim&eacute;trica de disoluciones estandarizadas de HCl deciformales con indicaci&oacute;n visual del tiempo asociado al punto de equivalencia experimental. Se monitore&oacute; el punto de equivalencia potenciom&eacute;tricamente con microelectrodos para pH y de referencia construidos en el laboratorio. Se compararon las incertidumbres asociadas a la microtitulaci&oacute;n propuesta con respecto a la determinaci&oacute;n en condiciones titulom&eacute;tricas convencionales. </font></p>     <p align="justify"><font size="2" face="Verdana"><b>Palabras clave: </b> microcoulombimetr&iacute;a, micropotenciometr&iacute;a, metrolog&iacute;a. </font></p> <hr>     <p align="justify"><font size="2" face="Verdana"><b>ABSTRACT</b></font></p>     <p align="justify"><font size="2" face="Verdana">Low cost equipment with locally materials to perform microcoulometric acid-base titrations with micropotentiometric endpoint detection were developed. Visual detection was also assayed. Statistical analysis was performed comparing results obtained with standard methods as well to evaluate the minimal instrumentation micro coulometer <i>MIMCoul </i>, performance <i>. </i></font></p>     <p align="justify"><font size="2" face="Verdana"><b>Keywords: </b> microISE, microcoulometry, metrology. </font></p> <hr>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><b><font size="3" face="Verdana">INTRODUCCI&Oacute;N</font></b></p>     ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">Los m&eacute;todos coulombim&eacute;tricos se fundamentan en las investigaciones electroqu&iacute;micas publicadas por Michael Faraday en 1834, principalmente en su primera ley que indica<sup>1-4</sup>: &quot;la masa de una sustancia alterada en un&nbsp;electrodo&nbsp;durante la&nbsp;electr&oacute;lisis es directamente proporcional a la cantidad de electricidad transferida al electrodo, si a trav&eacute;s de este se hace pasar durante el tiempo una&nbsp;corriente continua&nbsp;de intensidad fija&quot;, es decir: </font></p>     <p align="justify"><img src="/img/revistas/ind/v26n2/e0105214.gif"></p>     
<p align="justify"><font size="2" face="Verdana">Un aspecto fundamental en la coulombimetr&iacute;a es la determinaci&oacute;n de la cantidad de electricidad consumida en el proceso: </font></p>     <p align="justify"><img src="/img/revistas/ind/v26n2/e0205214.gif"></p>     
<p align="justify"><font size="2" face="Verdana">Otro aspecto importante de esta t&eacute;cnica es la selectividad de la reacci&oacute;n electroqu&iacute;mica, pues la selecci&oacute;n de los electrodos y los medios de reacci&oacute;n &uacute;nicamente deben transformar la sustancia de inter&eacute;s. </font></p>     <p align="justify"><font size="2" face="Verdana">La coulombimetr&iacute;a como t&eacute;cnica electroanal&iacute;tica titulom&eacute;trica se basa en la generaci&oacute;n por electrolisis in situ del titulante y, como la mayor&iacute;a de los m&eacute;todos cuantitativos de an&aacute;lisis, originalmente fue desarrollada en condiciones de escala convencional o a macroescala, lo que encarece la t&eacute;cnica por el uso de macroelectrodos de platino, potenciostatos y amperostatos de elevado costo. Dado que la electrotransformaci&oacute;n es exhaustiva los tiempos de operaci&oacute;n son largos y se pueden tener an&aacute;lisis de horas, lo que limita la pr&aacute;ctica coulombim&eacute;trica convencional. Este trabajo muestra que la miniaturizaci&oacute;n y el microescalamiento son &uacute;tiles para reducir dichos inconvenientes de la determinaci&oacute;n a escala convencional<sup>8-13</sup>. </font></p>     <p align="justify"><font size="2" face="Verdana">Las valoraciones coulombim&eacute;tricas &aacute;cido-base se fundamentan en la electrogeneraci&oacute;n de los iones titulantes H<sup>+</sup> o bien OH<sup>-</sup>, apartir de la electr&oacute;lisis de una disoluci&oacute;n acuosa en presencia de un electrolito qu&iacute;mica y electroqu&iacute;micamente inerte (conocido como electrolito soporte). El lionio, H<sup>+</sup>, y el liato, OH<sup>-</sup>, corresponden a las especies &aacute;cidas y b&aacute;sicas m&aacute;s fuertes en el agua por lo que las reacciones operativas de titulaci&oacute;n con estas especies presentan un porcentaje de reacci&oacute;n o cuantitatividad mayor al 99.99 % lo que corresponde a reacciones muy cuantitativas<sup>5</sup>. </font></p>     <p align="justify"><font size="2" face="Verdana">La electroxidaci&oacute;n del agua produce: </font></p>     <p align="justify"> <img src="/img/revistas/ind/v26n2/e0305214.gif"> </p>     
<p align="justify"><font size="2" face="Verdana">y al reducir la misma, la reacci&oacute;n electroqu&iacute;mica es: </font></p>     ]]></body>
<body><![CDATA[<p align="justify"><img src="/img/revistas/ind/v26n2/e0405214.gif"></p>     
<p align="justify"><font size="2" face="Verdana">El MIMCoul requiere solo de un electrodo de trabajo, ET, y un electrodo auxiliar, EA. Entre ellos se impone una diferencia de potencial constante, la transferencia de masa constante se garantiza mediante una agitaci&oacute;n vigorosa permanente. </font></p>     <p align="justify"><font size="2" face="Verdana">En estas condiciones, la corriente de electr&oacute;lisis es constante y estar&aacute; limitada por la reacci&oacute;n operativa de titulaci&oacute;n acoplada a la electrogeneraci&oacute;n del titulante. El ET ser&aacute; el c&aacute;todo para la titulaci&oacute;n de &aacute;cidos, o el &aacute;nodo para la titulaci&oacute;n de bases: </font></p>     <p align="justify"><font size="2" face="Verdana">ET, c&aacute;todo, (-): <img src="/img/revistas/ind/v26n2/e0405214.gif">(reacci&oacute;n electroqu&iacute;mica, E) </font></p>     
<p align="justify"><font size="2" face="Verdana">OH<sup>-</sup> + HA = A - + H<sub>2</sub>O (reacci&oacute;n qu&iacute;mica, C) </font></p>     <p align="justify"><font size="2" face="Verdana">ET, &aacute;nodo, (+): <img src="/img/revistas/ind/v26n2/e0305214.gif">(reacci&oacute;n electroqu&iacute;mica, E) </font></p>     
<p align="justify"><font size="2" face="Verdana">H<sup>+</sup> + A - = HA + H<sub>2</sub>O (reacci&oacute;n qu&iacute;mica, C) </font></p>     <p align="justify"><font size="2" face="Verdana">De esta manera las microtitulaciones coulobim&eacute;tricas se fundamentan en mecanismos EC respectivos en condiciones de transferencia de carga y de masa en <i>estado estacionario. </i> Las reacciones electroqu&iacute;micas de la celda total deben estar compartamentalizadas, lo cual se logra por aislamiento del EA con un recubrimiento de papel absorbente. </font></p>     <p align="justify"><font size="2" face="Verdana">Mediante la construcci&oacute;n de un microcoulomb&iacute;metro de m&iacute;nima instrumentaci&oacute;n, <i>MIMCoul </i>, con materiales locales de bajo costo se contribuir&aacute; a la ense&ntilde;anza y la pr&aacute;ctica de la qu&iacute;mica anal&iacute;tica instrumental bajo la siguiente premisa: &quot;se aprende m&aacute;s desarrollando la instrumentaci&oacute;n, que comprando la misma&quot;. Nuestra propuesta est&aacute; encaminada a aplicar los fundamentos te&oacute;ricos de la qu&iacute;mica anal&iacute;tica instrumental y el funcionamiento de los equipos, para posteriormente trabajar con los de manufactura de manera m&aacute;s eficiente y segura. </font></p>     <p align="justify"><font size="2" face="Verdana">El objetivo general de este trabajo es desarrollar un microcoulomb&iacute;metro para realizar valoraciones coulombim&eacute;tricas, donde se vean involucrados equilibrios qu&iacute;micos de car&aacute;cter &aacute;cido-base, con la m&iacute;nima instrumentaci&oacute;n posible y f&aacute;cil acceso. </font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">Los objetivos particulares son: </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Determinar la concentraci&oacute;n exacta de una disoluci&oacute;n de HCl de F= 0,1 mol/L a trav&eacute;s de una valoraci&oacute;n titulom&eacute;trica microcoulombim&eacute;trica. </font></p>     <p align="justify"><font size="2" face="Verdana">Estimar la incertidumbre en la determinaci&oacute;n. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Comparar la concentraci&oacute;n exacta del analito y su incertidumbre asociada respecto a aquella obtenida por el m&eacute;todo volum&eacute;trico oficial utilizando como patr&oacute;n primario <span class="Cuerpodetexto"><font size="2" face="Verdana">Na<sub>2</sub>CO<sub>3</sub></font></span> anhidro. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Acoplar a la microcelda de titulaci&oacute;n microcoulombim&eacute;trica un sistema de monitoreo micropotenciom&eacute;trico de producci&oacute;n local con captura de datos digital en tiempo real. </font></p>     <p align="justify"><font size="2" face="Verdana">La miniaturizaci&oacute;n de la titulaci&oacute;n coulombim&eacute;trica propuesta no invalida la aplicaci&oacute;n de las leyes de Faraday y, por lo tanto, los resultados que arroja son susceptibles de un an&aacute;lisis metrol&oacute;gico. </font></p>     <p align="justify"><font size="2" face="Verdana"><b>Metodolog&iacute;a </b></font></p>     <p align="justify"><font size="2" face="Verdana">Se desarrolla un sistema electroqu&iacute;mico de acuerdo con los siguientes diagramas esquem&aacute;ticos de los dos casos de microcoulomb&iacute;metro a construir: </font></p>     <p align="justify">&nbsp; </p>     <p align="justify"><font size="2" face="Verdana"><b>Caso 1 </b>, con monitoreo visual: </font></p>     ]]></body>
<body><![CDATA[<p align="center"><font size="2" face="Verdana"><img src="/img/revistas/ind/v26n2/e0505214.jpg">&nbsp; </font></p>     
<p align="justify"><font size="2" face="Verdana"><b>Caso 2 </b>, con monitoreo micropotenciom&eacute;trico: </font></p>     <p align="center"><img src="/img/revistas/ind/v26n2/e0605214.jpg"></p>     
<p align="justify"><font size="2" face="Verdana"><b>Materiales para la construcci&oacute;n del microcoulomb&iacute;metro </b></font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Frasco de pl&aacute;stico transparente con forma cil&iacute;ndrica de 2,5 cm de ancho por 3,0 cm de alto, capacidad de 5,0 mL, el cual funcionar&aacute; como celda (<a href="#1">figura 1</a>). Su tapa debe ser bihoradada para colocar los electrodos ET y EA (<a href="#4">figura 4</a>). </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Puntas de carb&oacute;n para l&aacute;pices de dibujo de 12 &middot; 2 mm HB de la marca STAEDTLER Mars&reg;carbon, que har&aacute;n el papel de electrodos (<a href="#3">figura 3</a>). </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Pila de 9.0 V de la marca Duracell&reg;. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Caimanes el&eacute;ctricos. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Barra de agitaci&oacute;n magn&eacute;tica de 7 &middot; 2 mm de la marca Spinbar&reg;. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Cron&oacute;metro (tel&eacute;fono celular). </font></p>     ]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Mult&iacute;metro de bajo costo con interfase RS232 integrada. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Jeringa para inyecci&oacute;n de insulina de 0,5 mL, marca BD&reg;. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Jeringa de 3,0 mL, marca SensiMedical&reg;. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Microagitador-LC (LowCoast) (<a href="#2">figura 2</a>). </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Papel secante para cocina Servitoallas. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Microsensor de pH de W<sup>0</sup>/WO<sub>3</sub> y microreferencia de Ag<sup>0</sup>/AgCl . </font></p>     <p align="center"><a name="1"></a><img src="/img/revistas/ind/v26n2/f0105214.jpg"></p>     
<p align="center"><font size="2" face="Verdana"><a name="2"></a><img src="/img/revistas/ind/v26n2/f0205214.jpg">&nbsp; </font></p>     
<p align="center"><a name="3"></a><img src="/img/revistas/ind/v26n2/f0305214.jpg"></p>     
<p align="center"><font size="2" face="Verdana"><a name="4"></a><img src="/img/revistas/ind/v26n2/f0405214.jpg">&nbsp; </font></p>     
]]></body>
<body><![CDATA[<p align="center"><font size="2" face="Verdana"></font></p>     <p align="justify"><font size="2" face="Verdana">La <a href="#5">figura 5</a> muestra el equipo completo para la realizaci&oacute;n de la Microtitulaci&oacute;n coulombimetrica con monitoreo visual. El mult&iacute;metro est&aacute; conectado en serie solamente para corroborar que la corriente impuesta es constante en un primer ensayo, y para posteriores determinaciones puede prescindirse de este. </font></p>     <p align="center"><font size="2" face="Verdana"><a name="5"></a><img src="/img/revistas/ind/v26n2/f0505214.jpg"></font></p>     
<p align="justify"><font size="2" face="Verdana">Una vez construido el equipo, nos enfrentamos al reto de la compartimentaci&oacute;n de los electrodos, es decir, c&oacute;mo separar los iones H<sup>+</sup> que se generan en el &aacute;nodo para que no interfieran en la titulaci&oacute;n, sin encarecer el sistema con una membrana comercial o tener que sintetizarla en nuestro laboratorio. </font></p>     <p align="justify"><font size="2" face="Verdana">Despu&eacute;s de varios experimentos de prueba y error se cubri&oacute; el &aacute;nodo con un pedazo de papel servitoalla (<a href="#6">figuras 6</a> y <a href="#7">7</a>) para evitar que los iones H<sup>+</sup> generados en el electrodo auxiliar contaminaran la muestra de an&aacute;lisis HCl. </font></p>     <p align="center"><font size="2" face="Verdana"><b><a name="6"></a><img src="/img/revistas/ind/v26n2/f0605214.jpg">&nbsp; </b></font></p>     
<p align="center"><b><a name="7"></a><img src="/img/revistas/ind/v26n2/f0705214.jpg"></b></p>     
<p align="justify"><font size="2" face="Verdana">Microcoulombimetr&iacute;a de HCl. Se agreg&oacute; a la celda de an&aacute;lisis 3,0 mL del electrolito soporte (KNO<sub>3</sub>  F = 0,5 mol/L) con una jeringa de 3,0 mL, posteriormente se colocaron dos gotas de indicador &aacute;cido-base verde de bromocresol (Vire de color amarillo en medio &aacute;cido a azul intenso en medio alcalino). Se evaluaron vol&uacute;menes de 100, 200, 300, 400 y 500 &micro;L de una disoluci&oacute;n de HCl F= 0,1 mol/L en cada ensayo. Se inici&oacute; la agitaci&oacute;n de la disoluci&oacute;n a un r&eacute;gimen constante. </font></p>     <p align="justify"><font size="2" face="Verdana">El &aacute;nodo se cubri&oacute; con el papel absorbente, que sirvi&oacute; como membrana separadora para evitar que los H<sup>+</sup> generados por la oxidaci&oacute;n de la disoluci&oacute;n interfieran con los H<sup>+</sup> provenientes de la disociaci&oacute;n del HCl, adem&aacute;s de evitar la oxidaci&oacute;n del Cl<sup>-</sup> a Cl<sub>2</sub>(g). Este &uacute;ltimo presenta una elevada reactividad que puede romper los dobles enlaces del verde de bromocresol y descomponerlo, lo que evitar&iacute;a observar el vire. La <a href="#8">figura 8</a> muestra esquem&aacute;ticamente el arreglo experimental. Se conectaron los electrodos a la fuente de poder, en este caso la pila que aplica un potencial nominal de 9.0 V, y con el amper&iacute;metro se midi&oacute; la corriente de electr&oacute;lisis asociada. Una vez conectados los electrodos a la fuente de poder se inici&oacute; la medici&oacute;n del tiempo hasta observar el vire del indicador. </font></p>     <p align="center"><font size="2" face="Verdana"><a name="8"></a><img src="/img/revistas/ind/v26n2/f0805214.jpg"></font></p>     
]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">Cada ensayo se repiti&oacute; diez veces para tener un mejor control de la dispersi&oacute;n de los datos. Se realiz&oacute; una valoraci&oacute;n titulom&eacute;trica cl&aacute;sica a escala convencional para conocer la concentraci&oacute;n exacta de nuestro &aacute;cido mediante el patr&oacute;n primario <span class="Cuerpodetexto"><font size="2" face="Verdana">Na<sub>2</sub>CO<sub>3</sub></font></span>, adem&aacute;s, se confrontaron los resultados obtenidos entre la titulaci&oacute;n a microescala y la titulaci&oacute;n a escala convencional. </font></p>     <p align="justify"><font size="2" face="Verdana">Una vez que la microcoulombimetr&iacute;a &aacute;cido-base de m&iacute;nima instrumentaci&oacute;n ha sido ensayada y monitoreada utilizando un indicador visual como detector del punto final de la valoraci&oacute;n, en este caso verde de bromocresol, se realiz&oacute; el monitoreo a trav&eacute;s de un par de microelectrodos dise&ntilde;ados y caracterizados en nuestro laboratorio para monitorear valoraciones volum&eacute;tricas potenciom&eacute;tricas (pH= f (V)). </font></p>     <p align="justify"><font size="2" face="Verdana">La instrumentaci&oacute;n consta de un sistema de un par de microelectrodos, un microsensor a pH de W<sup>0</sup>/WO<sub>3</sub> con una pureza mayor al 99 % y un microelectrodo de referencia de Ag<sup>0</sup>/AgCl. El monitoreo del potencial se llev&oacute; a cabo, en todo momento, con un mult&iacute;metro de la marca Steren &reg; modelo MUL-600, el cual incluye un programa igualmente denominado por los fabricantes como MUL-600 y su respectiva interfaz RS232 para conectarse a una PC. </font></p>     <p align="justify"><font size="2" face="Verdana">De esta manera fue posible monitorear la evoluci&oacute;n del potencial, ya que tambi&eacute;n se pueden registrar valores de resistencia, corriente y temperatura. El equipo es capaz de registrar el valor de la magnitud medida con respecto al tiempo, con una velocidad de adquisici&oacute;n de hasta tres datos por segundo, adem&aacute;s, es posible guardar los datos obtenidos en hojas de c&aacute;lculo para su posterior an&aacute;lisis. </font></p>     <p align="justify">&nbsp;</p> <b><font size="3" face="Verdana">RESULTADOS</font></b>     <p align="justify"><font size="2" face="Verdana">La <a href="#t1">tabla 1</a> muestra los tiempos de vire del indicador y la corriente medida durante la microtitulaci&oacute;n coulombim&eacute;trica, as&iacute; como la desviaci&oacute;n est&aacute;ndar asociada. Se corrobora que la dosificaci&oacute;n electroanal&iacute;tica del titulante es constante toda vez que la corriente impuesta es constante, lo que garantiza la validez de las ecuaciones de Faraday para determinar la masa electrolizada de &aacute;cido acoplada a la reacci&oacute;n electroqu&iacute;mica. </font></p>     <p align="center"><font size="2" face="Verdana"><b><a name="t1"></a>Tabla 1. Resultados experimentales para el tiempo de vire en cada adici&oacute;n de masa de HCl</b></font></p>     <div align="justify">   <table width="521" border="1" align="center" cellpadding="0" cellspacing="0" bordercolor="#000000">     <tr>       <td width="123">    <p align="center"><font size="2" face="Verdana"><b>t promedio vire[s] </b></font></p></td>       <td width="90">    <p align="center"><b><font size="2" face="Verdana">HCl [mol] </font></b></p></td>       <td width="105">    ]]></body>
<body><![CDATA[<p align="center"><b><font size="2" face="Verdana">i promedio [A] </font></b></p></td>       <td width="184">    <p align="center"><b><font size="2" face="Verdana">S t (desviaci&oacute;n est&aacute;ndar para el tiempo) </font></b></p></td>     </tr>     <tr>       <td width="123">    <p align="center"><font size="2" face="Verdana">14.25 </font></p></td>       <td width="90">    <p align="center"><font size="2" face="Verdana">0.00001 </font></p></td>       <td width="105">    <p align="center"><font size="2" face="Verdana">0.242 </font></p></td>       <td width="184">    <p align="center"><font size="2" face="Verdana">0.015951 </font></p></td>     </tr>     <tr>       <td width="123">    <p align="center"><font size="2" face="Verdana">29.52 </font></p></td>       <td width="90">    <p align="center"><font size="2" face="Verdana">0.00002 </font></p></td>       <td width="105">    <p align="center"><font size="2" face="Verdana">0.242 </font></p></td>       <td width="184">    <p align="center"><font size="2" face="Verdana">0.050870 </font></p></td>     </tr>     <tr>       <td width="123">    ]]></body>
<body><![CDATA[<p align="center"><font size="2" face="Verdana">45.62 </font></p></td>       <td width="90">    <p align="center"><font size="2" face="Verdana">0.00003 </font></p></td>       <td width="105">    <p align="center"><font size="2" face="Verdana">0.242 </font></p></td>       <td width="184">    <p align="center"><font size="2" face="Verdana">0.168584 </font></p></td>     </tr>     <tr>       <td width="123">    <p align="center"><font size="2" face="Verdana">58.00 </font></p></td>       <td width="90">    <p align="center"><font size="2" face="Verdana">0.00004 </font></p></td>       <td width="105">    <p align="center"><font size="2" face="Verdana">0.241 </font></p></td>       <td width="184">    <p align="center"><font size="2" face="Verdana">0.066609 </font></p></td>     </tr>     <tr>       <td width="123">    <p align="center"><font size="2" face="Verdana">75.72 </font></p></td>       <td width="90">    <p align="center"><font size="2" face="Verdana">0.00005 </font></p></td>       <td width="105">    ]]></body>
<body><![CDATA[<p align="center"><font size="2" face="Verdana">0.241 </font></p></td>       <td width="184">    <p align="center"><font size="2" face="Verdana">0.176826 </font></p></td>     </tr>   </table> </div>     <p align="justify"><font size="2" face="Verdana">La <a href="#9">figura 9</a> muestra la curva de calibraci&oacute;n ponderada, mol = f(t vire ), para los diez ensayos realizados. Se observa la validez faradaica de la microtitulaci&oacute;n, r<sup>2</sup> = 0,997 5. </font></p>     <p align="center"><font size="2" face="Verdana"><a name="9"></a><img src="/img/revistas/ind/v26n2/f0905214.gif"></font></p>     
<p align="justify"><font size="2" face="Verdana">Una vez verificada la validez faradaica experimental del m&eacute;todo, se procedi&oacute; a realizar el c&aacute;lculo de la concentraci&oacute;n de la disoluci&oacute;n de HCl F = 0,1 mol/L, de acuerdo con la <a href="#e1">ecuaci&oacute;n 1</a>. </font></p>     <p align="center"><a name="e1"></a><img src="/img/revistas/ind/v26n2/e0705214.gif"></p>     
<p align="justify"><font size="2" face="Verdana">donde es la intensidad de corriente aplicada, el volumen de HCl agregado a la celda, el n&uacute;mero de electrones intercambiados (en este caso 2e<sup>-</sup>), la constante de Faraday (96 485,34 C/mol) y el tiempo de vire. </font></p>     <p align="justify"><font size="2" face="Verdana">Con esta ecuaci&oacute;n fueron evaluados los cincuenta datos obtenidos experimentalmente. Se obtuvo un valor de CHCl= 0,180 9 mol/L como concentraci&oacute;n exacta de la disoluci&oacute;n. </font></p>     <p align="justify"><font size="2" face="Verdana">Determinaci&oacute;n de las fuentes de incertidumbre &quot;cuantificables&quot;, para estimar la incertidumbre de la determinaci&oacute;n: </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; <img src="/img/revistas/ind/v26n2/e0805214.gif">, asociada instrumentalmente al mult&iacute;metro utilizado. </font></p>     
]]></body>
<body><![CDATA[<p align="justify"><font size="2" face="Verdana">&#149;&nbsp; <img src="/img/revistas/ind/v26n2/e0905214.gif">, atribuida al cron&oacute;metro empleado. </font></p>     
<p align="justify"><font size="2" face="Verdana">&#149;&nbsp; <img src="/img/revistas/ind/v26n2/e1005214.gif">, asociada a la jeringa con la que se tom&oacute; la al&iacute;cuota del &aacute;cido. </font></p>     
<p align="justify"><font size="2" face="Verdana">&#149;&nbsp;  u <sub>repetibilidad</sub>, la que representa que tan reproducible fue la t&eacute;cnica. </font></p>     <p align="justify"><font size="2" face="Verdana">De acuerdo con la <i>Gu&iacute;a para estimar la incertidumbre de una medici&oacute;n, </i>CENAM 2004, tomando en cuenta porcentajes de coeficientes de variaci&oacute;n, desviaciones est&aacute;ndar, promedios y qu&eacute; distribuci&oacute;n sigue cada instrumento utilizado, la ecuaci&oacute;n final para determinar la incertidumbre relativa de la determinaci&oacute;n es<sup>6, 7</sup>: </font></p>     <p align="justify" class=MsoNormal>   <font size="2" face="Verdana">    <o:p><img src="/img/revistas/ind/v26n2/e1105214.gif"></o:p></font></p>     
<p align="justify" class=Cuerpodetexto><font size="2" face="Verdana">El valor de la incertidumbre expandida con un 95,5 % de confianza, K = 2, es:<o:p></o:p></font></p>     <p align="justify" class=Cuerpodetexto>   <font size="2" face="Verdana">u <sub>c HCl</sub> = 0.0054 mol/L    <![endif]>   <o:p></o:p></font></p>     <p align="justify" class=Cuerpodetexto><font size="2" face="Verdana">Por lo que la concentraci&oacute;n real de la disoluci&oacute;n qued&oacute; expresada como:<o:p></o:p></font></p>     <p align="justify" class=Cuerpodetexto>   <font size="2" face="Verdana">     <font size="2" face="Verdana">u <sub>EXP K=2</sub> = 0.0108 mol/L <![endif]>   </font>   <![endif]>   <o:p></o:p></font></p>     <p align="justify" class=Cuerpodetexto><font size="2" face="Verdana"><o:p></o:p>La estandarizaci&oacute;n de la disoluci&oacute;n por el m&eacute;todo volum&eacute;trico cl&aacute;sico realizado con material de manufactura arroj&oacute; los siguientes datos para el patr&oacute;n primario: n = 10, masa de Na<sub>2</sub>CO<sub>3</sub> promedio de 0,040 3 g con s = 0,000 18 y % CV = 0,44; y los siguientes para el HCl como analito: n = 10, CHCl = 0,163 1 mol/L, s = 0,000 65 y % CV= 0,40.<o:p></o:p></font></p>     ]]></body>
<body><![CDATA[<p align="justify" class=Cuerpodetexto><font size="2" face="Verdana"><o:p>La ecuaci&oacute;n para la estimaci&oacute;n de la incertidumbre relativa de la determinaci&oacute;n basada en la misma gu&iacute;a es:</o:p></font></p> <h1 align="justify"><font size="2" face="Verdana"><img src="/img/revistas/ind/v26n2/e1205214.gif"> </font></h1>     
<p align="justify"> <font size="2" face="Verdana"><span class="Cuerpodetexto"><font size="2" face="Verdana">u <sub>c HCl</sub> = 0.0012</font></span> mol/L </font></p>     <p align="justify"><font size="2" face="Verdana">El valor de la incertidumbre expandida con un 95,5 % de confianza, K = 2, es:</font></p>     <p align="justify"> <font size="2" face="Verdana"><span class="Cuerpodetexto"><font size="2" face="Verdana"><font size="2" face="Verdana">u <sub>EXP K=2</sub> = 0.0024 mol/L           <![endif]> </font>         <![endif]>         <o:p></o:p></font></span></font></p>     <p align="justify"><font size="2" face="Verdana">Por lo tanto la concentraci&oacute;n real de la disoluci&oacute;n de este &aacute;cido est&aacute; expresada como: </font></p>     <p align="justify"><font size="2" face="Verdana">C <sub>HCl</sub> = [0.1631 &plusmn; 0.0024] mol/L. </font></p>     <p align="justify"><font size="2" face="Verdana"><b>An&aacute;lisis de resultados de la microtitulaci&oacute;n con monitoreo visual </b></font></p>     <p align="justify"><font size="2" face="Verdana">Como se puede observar en la figura 9, la curva de calibraci&oacute;n arroj&oacute; un excelente coeficiente de correlaci&oacute;n si tomamos en cuenta el material de bajo costo que se utiliz&oacute; para la construcci&oacute;n del equipo. </font></p>     <p align="justify"><font size="2" face="Verdana">La siguiente tabla compara los resultados obtenidos con ambos m&eacute;todos: </font></p>     <div align="justify">   <table border="1" align="center" cellpadding="0" cellspacing="0" bordercolor="#000000">     <tr>       <td width="251" valign="top">    ]]></body>
<body><![CDATA[<p align="center"><font size="2" face="Verdana"><b>T&eacute;cnica Microcoulombim&eacute;trica </b></font></p></td>       <td width="251" valign="top">    <p align="center"><font size="2" face="Verdana"><b>T&eacute;cnica Volum&eacute;trica </b></font></p></td>     </tr>     <tr>       <td width="251" valign="top">    <p align="center"><font size="2" face="Verdana">C HCl = [ 0.1809 &plusmn; 0.0108] mol/L </font></p></td>       <td width="251" valign="top">    <p align="center"><font size="2" face="Verdana">C HCl = [0.1631 &plusmn; 0.0024] mol/L </font></p></td>     </tr>   </table> </div>     <p align="justify"><font size="2" face="Verdana"><b>Monitoreo micropotenciom&eacute;trico alternativo<sup>14</sup></b></font></p>     <p align="justify"><font size="2" face="Verdana">La calibraci&oacute;n del microsensor de pH tuvo una respuesta lineal en el proceso de calibraci&oacute;n: </font></p>     <p align="justify"><font size="2" face="Verdana">DE= -52,183 3pH + 100,833 </font></p>     <p align="justify"><font size="2" face="Verdana">Una vez calibrado el microsensor se realizaron los siguientes experimentos: </font></p>     <p align="justify"><font size="2" face="Verdana">Valoraciones microcoulombim&eacute;tricas de al&iacute;cuotas 100, 200, 300, 400 y 500 &micro;L de una disoluci&oacute;n de HCl F = 0,1 mol/L de acuerdo con las condiciones de la microtitulaci&oacute;n con indicador visual, midiendo el potencial del microsensor de pH en funci&oacute;n del tiempo de electr&oacute;lisis. </font></p>     <p align="justify"><font size="2" face="Verdana">En la siguiente <a href="/img/revistas/ind/v26n2/f1005214.jpg" target="_blank">gr&aacute;fica</a> se muestran las curvas DE/ER = f (tv) obtenidas para cada experimento. </font></p>      
]]></body>
<body><![CDATA[<div align="justify"><font size="2" face="Verdana">   <![endif]>   <!--[if gte vml 1]></o:wrapblock><![endif]-->    </font> </div>     <p align="justify">&nbsp;</p>     <p align="justify"><b><font size="3" face="Verdana">CONCLUSIONES</font></b></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Se desarroll&oacute; un sistema microcoulombim&eacute;trico de m&iacute;nima instrumentaci&oacute;n MIMCoul , con una precisi&oacute;n aceptable para este tipo de m&eacute;todos. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; La metodolog&iacute;a propuesta demuestra su potencial uso en la cuantificaci&oacute;n de diversos analitos de naturaleza &aacute;cido-base en qu&iacute;mica de alimentos, control de medicamentos, qu&iacute;mica ambiental, m&eacute;todo de Karl Fisher para titulaci&oacute;n de H<sub>2</sub>O y entitulometr&iacute;a en general con las ventajas inherentes al microescalamiento en cuanto costos, generaci&oacute;n de desechos y tiempos de operaci&oacute;n, adem&aacute;s del ahorro de disoluciones patr&oacute;n de NaOH en particular. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; Fue posible detectar cantidades en el intervalo de 10 a 60 de HCl, lo que representa una ventaja en sensibilidad con respecto a la volumetr&iacute;a convencional. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; La introducci&oacute;n del sistema micropotenciom&eacute;trico acredita la precisi&oacute;n y exactitud de la cuantificaci&oacute;n y la posibilidad de caracterizaci&oacute;n termodin&aacute;mica del sistema analizado. </font></p>     <p align="justify"><font size="2" face="Verdana">&#149;&nbsp; La metodolog&iacute;a propuesta hace viable la ense&ntilde;anza experimental de las Leyes de Faraday y de los m&eacute;todos coulombim&eacute;tricos de an&aacute;lisis. </font></p>     <p align="justify">&nbsp; </p> <b><font size="3" face="Verdana">BIBLIOGRAF&Iacute;A</font></b>     <!-- ref --><p align="justify"><font size="2" face="Verdana">1. BOTT, A. W.; HEINEMAN, W. R. &quot;Chronocoulometry&quot;. Current Separations.2004, 20, 4, p. 121-126.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 2. TOCK, J. T. &quot;CoulometricTriatons in Nonaqueous Media&quot;.   Journal of Chemical Education.1973, 50, April, p. 268-269.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 3. BARD, A. J. &quot;Electroanalysis and Coulometric&quot;. Analytical   Chemistry. 1966, 38, April, p. 88-92.    </font></p>     <p align="justify"><font size="2" face="Verdana"> 4. EHL, R. G.; IHDE, A. &quot;Faraday&rsquo;s Electrochemical Laws and   the Determination of Equivalent Weights&quot;. Journal of   Chemical Education. 1954, 31, May, p. 226-232.</font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 5. PINGARR&Oacute;N, J. M.; S&Aacute;NCHEZ BATANERO, P.Qu&iacute;mica   Electroanal&iacute;tica. Fundamentos y aplicaciones. 2a ed. Madrid:   Editorial S&iacute;ntesis, 2003.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 6. WOLFGANG, A.; LAZOS MART&Iacute;NEZ, R. J. GUM Gu&iacute;a   para estimar la incertidumbre de una medici&oacute;n. M&eacute;xico:   CENAM, 2004.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font size="2" face="Verdana"> 7. VIM (vocabulario internacional de metrolog&iacute;a. Conceptos   fundamentales y generales, y t&eacute;rminos asociados). 3a ed.   Madrid: Centro Espa&ntilde;ol de Metrolog&iacute;a, 2008.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 8. BAEZA, A. &quot;Microbureta a Microescala total para   titulometr&iacute;a&quot;. Rev. Chil. Educ. Cient. 2003, 1, 2, p. 4-7.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 9. BAEZA, A. &quot;Titulaciones &aacute;cido-base potenciom&eacute;tricas a microescala   total con microsensores de pH y de referencia de bajo costo&quot;.   Rev. Chil. Educ. Cient. 2003, 1, 2, p. 16-19.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana">10. VARGAS, J.; BAEZA, A.; URZ&Uacute;A, T.; RODR&Iacute;GUEZ,   J.; C&Aacute;CERES, L. &quot;Titulaciones &aacute;cido-base a microescala   qu&iacute;mica usando microsensores de pH y microelectrodo de   referencia: Adquisici&oacute;n de datos con nuevas tecnolog&iacute;as&quot;. Rev. Chil. Educ. Cient.2004, 2, 2, p. 25-29.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 11. BAEZA, A.; DE SANTIAGO, A.; GALICIA, E.&quot;Titulaciones de halogenuros a microescala total con microsensores de Ag y de microreferencia de bajo costo sin puente salino&quot;. Rev. Chil. Educ. Cient.2004, 3, 1, p. 22-25.    </font></p>     ]]></body>
<body><![CDATA[<!-- ref --><p align="justify"><font size="2" face="Verdana"> 12. MART&Iacute;NEZ, J. M.; BAEZA, A. &quot;Qu&iacute;mica Microanal&iacute;tica,   determinaci&oacute;n de &aacute;cido acetilsalis&iacute;lico (FEUM) con   Microfotocolor&iacute;metro de M&iacute;nima Instrumentaci&oacute;n MIMC,   de bajo costo&quot;. Revista Cubana de Qu&iacute;mica. 2004, 16, 3, p. 29-39.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 13. CASSANOVA, J.; BAEZA, A. &quot;Estudio integral del cloro   en desinfectantes hospitalarias con Micropolar&oacute;grafo de   M&iacute;nima Intrumentaci&oacute;n, MIMP&quot;. Revista Cubana de Qu&iacute;mica. 2005, 18, 1, p. 43-51.    </font></p>     <!-- ref --><p align="justify"><font size="2" face="Verdana"> 14. VIERNA, L.; GARC&Iacute;A MENDOZA, A.; BAEZA, A.&quot;Microscale Analytical Potentiometry: Experimental Teaching with Locally Produced Low-Cost Instrumentation&quot;. Journal of Modern Education Review. 2013, 3, 5, p. 407-415.     </font></p>     <p align="justify">&nbsp;</p>     <p align="justify">&nbsp;</p>     <p><font size="2" face="Verdana">Recibido: 05/04/2014    <br> Aceptado: 20/05/2014</font></p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p>     <p align="justify"><font size="2" face="Verdana"><i>Dr. Alejandro Baeza-Reyes.</i> Facultad de Qu&iacute;mica, Ciudad Universitaria, D.F., M&eacute;xico, <a href="mailto:baeza@unam.mx">baeza@unam.mx</a></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BOTT]]></surname>
<given-names><![CDATA[A. W]]></given-names>
</name>
<name>
<surname><![CDATA[HEINEMAN]]></surname>
<given-names><![CDATA[W. R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Chronocoulometry]]></article-title>
<source><![CDATA[]]></source>
<year>2004</year>
<volume>20</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>121-126</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[TOCK]]></surname>
<given-names><![CDATA[J. T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[CoulometricTriatons in Nonaqueous Media]]></article-title>
<source><![CDATA[]]></source>
<year>1973</year>
<volume>50</volume>
<numero>April</numero>
<issue>April</issue>
<page-range>268-269</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BARD]]></surname>
<given-names><![CDATA[A. J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Electroanalysis and Coulometric]]></article-title>
<source><![CDATA[]]></source>
<year>1966</year>
<volume>38</volume>
<numero>April</numero>
<issue>April</issue>
<page-range>88-92</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[EHL]]></surname>
<given-names><![CDATA[R. G]]></given-names>
</name>
<name>
<surname><![CDATA[IHDE]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Faraday&#8217;s Electrochemical Laws and the Determination of Equivalent Weights]]></article-title>
<source><![CDATA[]]></source>
<year>1954</year>
<volume>31</volume>
<numero>May</numero>
<issue>May</issue>
<page-range>226-232</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[PINGARRÓN]]></surname>
<given-names><![CDATA[J. M]]></given-names>
</name>
<name>
<surname><![CDATA[SÁNCHEZ BATANERO]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
</person-group>
<source><![CDATA[Química Electroanalítica. Fundamentos y aplicaciones]]></source>
<year>2003</year>
<edition>2</edition>
<publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Editorial Síntesis]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[WOLFGANG]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[LAZOS MARTÍNEZ]]></surname>
<given-names><![CDATA[R. J]]></given-names>
</name>
</person-group>
<source><![CDATA[GUM Guía para estimar la incertidumbre de una medición]]></source>
<year>2004</year>
<publisher-name><![CDATA[CENAM]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="book">
<source><![CDATA[VIM (vocabulario internacional de metrología. Conceptos fundamentales y generales, y términos asociados]]></source>
<year>2008</year>
<edition>3</edition>
<publisher-loc><![CDATA[Madrid ]]></publisher-loc>
<publisher-name><![CDATA[Centro Español de Metrología]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BAEZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Microbureta a Microescala total para titulometría]]></article-title>
<source><![CDATA[]]></source>
<year>2003</year>
<volume>1</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>4-7</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BAEZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Titulaciones ácido-base potenciométricas a microescala total con microsensores de pH y de referencia de bajo costo]]></article-title>
<source><![CDATA[]]></source>
<year>2003</year>
<volume>1</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>16-19</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[VARGAS]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[BAEZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[URZÚA]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[RODRÍGUEZ]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[CÁCERES]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Titulaciones ácido-base a microescala química usando microsensores de pH y microelectrodo de referencia: Adquisición de datos con nuevas tecnologías]]></article-title>
<source><![CDATA[]]></source>
<year>2004</year>
<volume>2</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>25-29</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[BAEZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[DE SANTIAGO]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[GALICIA]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Titulaciones de halogenuros a microescala total con microsensores de Ag y de microreferencia de bajo costo sin puente salino]]></article-title>
<source><![CDATA[]]></source>
<year>2004</year>
<volume>3</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>22-25</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[MARTÍNEZ]]></surname>
<given-names><![CDATA[J. M]]></given-names>
</name>
<name>
<surname><![CDATA[BAEZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Química Microanalítica, determinación de ácido acetilsalisílico (FEUM) con Microfotocolorímetro de Mínima Instrumentación MIMC, de bajo costo]]></article-title>
<source><![CDATA[]]></source>
<year>2004</year>
<volume>16</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>29-39</page-range></nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[CASSANOVA]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[BAEZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Estudio integral del cloro en desinfectantes hospitalarias con Micropolarógrafo de Mínima Intrumentación, MIMP]]></article-title>
<source><![CDATA[]]></source>
<year>2005</year>
<volume>18</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>43-51</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[VIERNA]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[GARCÍA MENDOZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[BAEZA]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Microscale Analytical Potentiometry: Experimental Teaching with Locally Produced Low-Cost Instrumentation]]></article-title>
<source><![CDATA[]]></source>
<year>2013</year>
<volume>3</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>407-415</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>