<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0034-7515</journal-id>
<journal-title><![CDATA[Revista Cubana de Farmacia]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Farm]]></abbrev-journal-title>
<issn>0034-7515</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0034-75152001000300010</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Irritación ocular: Modelos alternativos]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Vega Montalvo]]></surname>
<given-names><![CDATA[Raiza]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Álvarez Fong]]></surname>
<given-names><![CDATA[Mayleng]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Centro de investigación y Desarrollo de Medicamentos  ]]></institution>
<addr-line><![CDATA[Ciudad de La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2001</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2001</year>
</pub-date>
<volume>35</volume>
<numero>3</numero>
<fpage>211</fpage>
<lpage>218</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0034-75152001000300010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0034-75152001000300010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0034-75152001000300010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[El ojo puede ser dañado accidentalmente por el uso de muchos productos de uso rutinario. Para facilitar la seguridad de los consumidores es necesario estimar el potencial de irritación ocular de estas sustancias químicas. Esta estimación está basada en los resultados obtenidos en el ensayo de Draize llevado a cabo en conejos. Sin embargo, avances en el desarrollo de la toxicología in vitro han permitido el uso de algunas alternativas para la evaluación del riesgo ocular; por lo que se presenta una revisión acerca de los diferentes métodos alternativos disponibles hasta el momento que permiten evaluar de una forma u otra los efectos tóxicos a nivel ocular.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The eye may be accidentally damaged by many products of daily use. To guarantee the consumers’ safety it is necessary to estimate the eye irritation potential of these chemical substances. This estimation is based on the results obtained in the Draize rabbit eye irritation test. However, the advances attained in the development of in vitro toxicology have allowed the use of some alternatives to evaluate the ocular risk. Therefore, a review is made on the different alternative methods available up to now that make possible the evaluation in one way or another of the toxic effects at the ocular level.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[IRRITANTES]]></kwd>
<kwd lng="es"><![CDATA[COSMETICOS]]></kwd>
<kwd lng="es"><![CDATA[OJO]]></kwd>
<kwd lng="es"><![CDATA[CONEJOS]]></kwd>
<kwd lng="es"><![CDATA[EVALUACION DE MEDICAMENTOS]]></kwd>
<kwd lng="es"><![CDATA[ANIMALES DE LABORATORIO]]></kwd>
<kwd lng="en"><![CDATA[IRRITANTS]]></kwd>
<kwd lng="en"><![CDATA[COSMETICS]]></kwd>
<kwd lng="en"><![CDATA[EYE]]></kwd>
<kwd lng="en"><![CDATA[RABBITS]]></kwd>
<kwd lng="en"><![CDATA[DRUG EVALUATION]]></kwd>
<kwd lng="en"><![CDATA[ANIMALS, LABORATORY]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <h5><a href="farsu301.htm">Indice</a> <a href="far09301.htm">Anterior</a> <a href="far11301.htm">Siguiente</a>    <br>   Rev Cubana Farm 2001;35(3):211-18</h5>     <p><a href="far10301.pdf"><img src="pdf.gif" width="24" height="23" border="0">Formato    PDF </a></p> <h3>Artículo de Revisión </h3>     <p>Centro de Investigación y Desarrollo de Medicamentos </p> <h2>Irritación ocular: Modelos alternativos</h2>     <p> <a href="#cargo">Raiza Vega Montalvo<span class="superscript">1</span> y Mayleng    Álvarez Fong<span class="superscript">2 </span></a><span class="superscript"><a name="autor"></a>    </span></p> <h4> Resumen </h4>     <p>El ojo puede ser dañado accidentalmente por el uso de muchos productos de uso    rutinario. Para facilitar la seguridad de los consumidores es necesario estimar    el potencial de irritación ocular de estas sustancias químicas. Esta estimación    está basada en los resultados obtenidos en el ensayo de Draize llevado a cabo    en conejos. Sin embargo, avances en el desarrollo de la toxicología in vitro    han permitido el uso de algunas alternativas para la evaluación del riesgo ocular;    por lo que se presenta una revisión acerca de los diferentes métodos alternativos    disponibles hasta el momento que permiten evaluar de una forma u otra los efectos    tóxicos a nivel ocular. </p>     <p>DeCS: IRRITANTES/toxicidad; COSMETICOS/toxicidad; OJO/lesiones; CONEJOS; EVALUACION    DE MEDICAMENTOS; ANIMALES DE LABORATORIO. </p>     <p>El hombre tiene conocimiento del mundo físico que le rodea mediante los órganos    de los sentidos; dentro de ellos, el ojo ocupa un lugar preponderante por su    capacidad de capturar la energía visible y convertirla en neuro-señales que    se transmiten a través del nervio óptico hacia el cerebro donde se produce la    visión.<span class="superscript">1 </span></p>     <p>El ojo se encuentra constantemente expuesto al ambiente, por lo que resulta    vulnerable al ataque de cualquier agente físico o químico que pudiera ocasionar    alteraciones, daño o pérdida de la visión en dependencia del grado de severidad    que cause. Por tales motivos resulta esencial estimar lo más rigurosamente posible    el potencial irritante de cualquier compuesto que pueda tener contacto con el    ojo y sus estructuras adyacentes.<span class="superscript">1 </span></p>     <p>Un ensayo que permite evaluar los eventos a este nivel y determinar la irritación    ocular que producen las sustancias químicas, medicamentos y cosméticos fue el    descrito por Draize en 1944. Desde su introducción este ensayo fue criticado    fuertemente tanto por razones éticas como científicas, lo que estimuló la búsqueda    de nuevas altenativas encaminadas a eliminar las deficiencias encontradas a    este, basadas fundamentalmente en la reducción del número de animales a utilizar,    el refinamiento de la metodología y el remplazamiento por métodos in vitro.<span class="superscript">2</span>  </p>     ]]></body>
<body><![CDATA[<p>Los modelos in vitro incluyen el uso de biomarcadores, cultivo de células,    órganos y tejidos, modelos farmacocinéticos, análisis de HPLC, así como la correlación    estructura- -actividad, y sus puntos finales están basados en el examen de la    morfología celular, la función fisiológica hística, la respuesta inflamatoria    o inmunológica y la recuperación o restablecimiento de los tejidos.<span class="superscript">3    </span></p>     <p>Las alternativas in vitro poseen ventajas potenciales sobre los ensayos in    vivo debido a su simplicidad, rapidez y a la cuantificación de los puntos finales,    además condicionan una reducción en el número de animales y una disminución    del dolor y el estrés de estos. </p> <h4>Eventos asociados con el daño ocular </h4>     <p>El ojo puede ser dividido funcional-mente en fotorreceptores (retina) que son    los encargados de conectar los ojos con el sistema nervioso central a través    de los nervios ópticos; en estructuras ópticas (córnea, iris, humor acuoso,    lente, el cuerpo ciliar y el cuerpo vítreo) cuya función se basa en concentrar    la luz visible sobre la retina y en estructuras protectoras, lubricantes y nutricionales.    Todas estas funciones oculares se encuentran en un balance delicado, y cualquier    lesión traumática, química o física puede afectarlas, creando un desorden de    la visión y en dependencia de su alcance hasta pérdida parcial o total de esta.<span class="superscript">1</span></p>     <p>La irritación del ojo inducida por sustancias químicas involucra la exposición    directa de organelos como la córnea, el iris y la conjuntiva. Los efectos sobre    estas estructuras pueden ser detectados fácilmente mediante la observación conjunta.    Los eventos asociados con el daño ocular se clasifican teniendo en cuenta los    criterios de irritación y corrosión:<span class="superscript">4 </span></p> <ul>       <li> La irritación ocular es un cambio inflamatorio reversible que ocurre en      la superficie anterior del ojo, seguido de la exposición directa a un material      y persiste durante 24 h. </li>       <li>La corrosión se considera un daño irreversible del tejido ocular debido      a la exposición de un material que provoca destrucción de los tejidos gruesos      del ojo. </li>       <li>Los irritantes oculares producen simultáneamente cambios en múltiples tejidos      oculares del segmento anterior del ojo. La severidad del daño en cada uno      se relaciona con la fortaleza del irritante y la recuperación depende del      grado y la extensión del daño a nivel de la propia célula.<span class="superscript">5      </span></li>     </ul>     <p>El grado de daño causado por un agente externo en la mucosa ocular depende    del pH, la capacidad de unión a proteínas epiteliales y de la penetración de    este en la córnea. Cuando un irritante penetra en el ojo se activan los mecanismos    protectores de este, la secreción de lágrimas aumenta y los vasos se dilatan    en función de eliminar o reducir la presencia de tal compuesto. Si la irritación    es severa la dilatación de los vasos aumenta y el fluido vascular y las proteínas    filtran hacia la conjuntiva causando edema y como consecuencia se afecta el    funcionamiento de los párpados. Las lesiones directas a nivel del iris se caracterizan    por un incremento de la vascularidad, engrosamiento del estroma, disminución    de la reacción a la luz, inflamación acuosa y/o destrucción del grosor del tejido.<span class="superscript">1</span></p> <h4>Ensayo de draize para la determinación de la irritación ocular </h4>     <p>El ensayo para la predicción de los efectos tóxicos de los cosméticos, medicamentos    y sustancias químicas sobre las membranas mucosas y la piel fue desarrollado    por Draize y otros en 1944.<span class="superscript">6</span> </p>     ]]></body>
<body><![CDATA[<p>Este ensayo permite evaluar los efectos oculares que aparecen por la exposición    aguda de los compuestos sobre la mucosa ocular del conejo, mediante la observación    de las reacciones que ocurren a nivel de córnea, iris y conjuntiva, y de acuerdo    con el sistema de Draize para evaluar la severidad de las lesiones oculares    producidas es posible clasificar los compuestos en cuanto a su potencial irritante.    Los resultados de este ensayo han sido usados durante años para la clasificación    de diferentes compuestos y han constituido la base de la norma No. 405 adoptada    por la Organización para la Cooperación y el Desarrollo Económico (OCDE) en    1981 y de la norma ISO/DIC-10 993 No.10 adoptada en 1992 para la conducción    de los ensayos de toxicidad ocular.<span class="superscript">7,8 </span></p> <h4>Críticas realizadas al ensayo de Draize </h4>     <p>El ensayo de Draize desde sus inicios ha sido fuertemente criticado por la    metodología empleada, la naturaleza subjetiva del ensayo, la relevancia del    modelo animal utilizado y por el dolor que causa a los animales.<span class="superscript">9    </span></p>     <p>La subjetividad ha sido demostrada en diversos estudios interlaboratorios donde    se han encontrado diferencias significativas entre los resultados.<span class="superscript">10</span>  </p>     <p>Algunos científicos opinan que la estimación se encuentra grandemente influenciada    por el número de animales utilizados y la duración del período de observación.<span class="superscript">11</span>  </p>     <p>Otros han tomado como argumento fundamental las diferencias estructurales y    fisiológicas que existen entre el ojo del conejo y el humano. En este aparece    una membrana nictitante o tercer párpado que puede remover o atrapar el irritante    lo que podría interferir en los resultados, su mecanismo lagrimal es menos efectivo    existiendo diferencias en cuanto al grado y el tiempo de permanencia del irritante    en el ojo, y además difieren en cuanto al pH del humor acuoso y el grosor medio    de la córnea.<span class="superscript">12 </span></p>     <p>El método de exposición de la sustancia de ensayo así como el volumen de aplicación    también han sido cuestionados, debido a que no se asemejan a lo que ocurre en    el hombre cuando es expuesto de forma accidental a cualquier agente externo.<span class="superscript">13</span></p> <h4>Modificaciones propuestas al ensayo de Draize </h4>     <p>Inicialmente Draize utilizó 9 animales, sin embargo, la FHSA (Federal Hazardous    Substancies Act) recomienda el uso de 6 animales para la prueba. Las normas    de la OCDE recomiendan un mínimo de 3 animales y 1 animal adicional siempre    que se requiera y su más reciente modificación incluye el uso de un solo animal    si se sospecha que el producto es altamente irritante.<span class="superscript">7    </span></p>     <p>Otras modificaciones incluyen una disminución en el volumen del material de    ensayo, debido a que se encuentra por encima del rango de cualquier exposición    en humanos y resulta superior a la capacidad del ojo del conejo que es aproximadamente    de 30 a 50 µL.<span class="superscript">14 </span></p>     <p>Esto fue comprobado en diversos estudios donde se aplicaron volúmenes menores    al reportado y se encontró que la respuesta de la córnea y la conjuntiva fueron    similar a la observada cuando se aplicó un volumen de 0,1 mL. Otro cambio propuesto    sugiere el previo tratamiento con anestésico para aliviar la irritación y el    dolor de los animales, así como la realización de un lavado posterior a la aplicación.<span class="superscript">15</span>  </p> <h4>Métodos alternativos al ensayo de irritación ocular </h4>     <p>Los métodos alternativos incluyen a todos aquellos procedimientos que pudieran    remplazar los experimentos realizados con animales, reducir el número de estos    a utilizar en cada ensayo o refinar la metodología ya existente en busca de    una disminución del dolor y el estrés, lo que se corresponde con el principio    de las “tres erres”.<span class="superscript">16</span> Muchos han sido los    ensayos in vitro descritos en la literatura que se proponen como alternativa    al ensayo de irritación ocular y son agrupados sobre la base del punto final    medido.<span class="superscript">17 </span></p>     ]]></body>
<body><![CDATA[<p>Los estudios que utilizan la evaluación morfológica o la observación que refleja    los cambios morfológicos a nivel celular están incluidos en el primer grupo    de ensayos, dentro de estos se encuentra el ensayo del ojo aislado del conejo    el cual es selectivo para irritantes severos. En este ensayo el efecto tóxico    de las sustancias es estimado por la aplicación de estas sobre la córnea. Los    efectos son medidos 4 h después del tratamiento donde la presencia de opacidad    corneal, la medición del grosor de la córnea, el daño a nivel del epitelio corneal    y la penetración de la fluorersceína a través de la córnea constituyen los puntos    finales del ensayo para la determinación del efecto tóxico de los compuestos.    Es un ensayo que no presenta dificultades técnicas, la principal dificultad    está en la evaluación de los 4 parámetros medibles que a veces resulta complicada.<span class="superscript">18    </span></p>     <p>En el segundo grupo de estudios se encuentran los ensayos de toxicidad celular    y dicho término incluye no solo letalidad celular sino también disfunción celular.    Esta categoría puede ser dividida en 3 subgrupos: ensayos de adhesión y proliferación    celular, ensayos de integridad de membrana y ensayos de metabolismo celular.    Numerosos ensayos utilizan la proliferación celular como indicador de citotoxidad;    el ensayo para la determinación de proteínas totales en células 3T3 de ratón    Balb c utiliza este parámetro como punto final, y mediante una reacción colorimétrica    es posible establecer una curva dosis-efecto y así determinar la concentración    del irritante que causa el 50 % de una disminución de las proteínas totales.<span class="superscript">19    </span></p>     <p>Existe otro gran grupo de pruebas que emplean los efectos sobre la integridad    de membranas para evaluar la citotoxicidad, dentro de estas el ensayo de las    celulas rojas sanguíneas. Existen ciertos compuestos químicos que pueden causar    daños sobre la membrana plasmática y/o desnaturalización de proteínas de membranas    y otras proteínas de diferentes células. Estos parámetros han sido usados en    combinación para predecir la irritación ocular de los surfactantes principalmente.    Una vez obtenida la concentración efectiva media, o sea, la que causa el 50    % de hemólisis y el índice de desnaturalización, se calcula el índice de irritación    mediante una relación entre ambas variables cuyo valor se compara en una tabla    para clasificar las sustancias.<span class="superscript">20,21</span> </p>     <p>Varios aspectos del metabolismo celular han sido investigados como base para    la evaluación de la toxicidad, uno de los más representativos lo constituye    el ensayo de la acumulación del colorante rojo neutro. Dicho ensayo utiliza    las células 3T3 de ratón como indicio de citotoxicidad. La cantidad de colorante    absorbido es directamente proporcional al número de células viables en el cultivo.    Se determina la concentración que provoca una reducción del 50 % en la retención    del rojo neutro mediante curvas dosis-respuesta, usadas como medida de citotoxicidad    debido a la capacidad que poseen los compuestos irritantes de romper las células    y provocar la salida del rojo neutro.<span class="superscript">22 </span></p>     <p>Otro grupo de ensayos permiten definir la respuesta fisiológica a nivel celular    y de tejido. El ensayo para la determinación de la conductividad eléctrica en    muestra de epidermis de ratas Wistar se encuentra dentro de estos, el cual está    basado en mediciones de la resistencia eléctrica a muestras de piel previamente    expuestas al material de ensayo y cuyo valor constituye un indicador de la integridad    del estrato córneo de la piel, donde una vez que se define que el material de    ensayo es irritante en piel se asume que resulta severamente irritante en el    ojo.<span class="superscript">18 </span></p>     <p>Dentro de los ensayos que permiten definir la respuesta fisiológica también    se encuentra el método de la determinación de la opacidad y permeabilidad en    córnea bovina aislada. Este ensayo utiliza estas 2 variables como punto final    para la estimación de las propiedades irritantes de las sustancias. La opacidad    es medida mediante el cambio en la transmisión de la luz que pasa a través de    la córnea mediante un opacitómetro, y la permeabilidad es medida espectrofotométricamente    a 490 nm sustituyendo el material de ensayo por fluoresceína.<span class="superscript">23    </span></p>     <p>Otra amplia clasificación de pruebas enfoca el problema sobre la evaluación    de la respuesta inflamatoria. Existen estudios que utilizan la membrana corioalantoidea;    se asume que los efectos irritantes agudos sobre los vasos pequeños y las proteínas    de membrana de este tipo de tejido son similares a los efectos inducidos en    el ojo por el mismo químico. En la mayoría de los protocolos desarrollados a    partir del protocolo inicial existen 3 puntos finales, donde la presencia de    lesiones vasculares como hemorragia, lisis y coagulación son la base para utilizar    esta técnica como un indicador de daños a nivel de membranas mucosas. Este ensayo    es aplicado a materiales no irritantes, medianamente e irritantes severos.<span class="superscript">24,25    </span></p>     <p>El último grupo de ensayos involucran la relación reparación/restablecimiento    de la estructura celular cuando ha sido expuesta a irritantes. Existen otros    ensayos que no se encuentran dentro del esquema de clasificación propuesto que    incluyen sistemas computacionales basados en la relación estructura-actividad    y pueden ser considerados como alternativa fiel y eficaces al ensayo de irritación    ocular: en este grupo podemos citar el ensayo de EYTEX. Este método permite    evaluar la irritación ocular basado en la capacidad que poseen las proteínas    de unirse a una matriz sintética provocando turbidez, la cual es directamente    proporcional a la irritación de la muestra.<span class="superscript">26 </span></p>     <p>Estos métodos alternativos presentan grandes ventajas, ya que pueden ser utilizados    como métodos de screening, para evaluar las potencialidades tóxicas de nuevas    formulaciones, son métodos sensibles donde las condiciones experimentales pueden    ser definidas, controladas, reproducidas y estandarizadas con gran rigurosidad,    “ más baratos” y éticos.<span class="superscript">27 </span></p> <h4>Conclusiones </h4>     <p>Existe un gran número de barreras que obstaculizan el desarrollo de estos ensayos,    ya que deben ser capaces de dar un nuevo enfoque para la identificación y la    evaluación del riesgo, además resulta necesario realizar la validación de ellos    usando un amplio rango de compuestos y laboratorios con vistas a que pudieran    ser aceptados en el contexto regulatorio, la posibilidad de sustituir los métodos    tradicionales por métodos novedosos hace que los científicos acostumbrados a    los ensayos de rutina se muestren escépticos, pues resulta difícil cambiar los    hábitos y se admitan otros enfoques experimentales para evaluar el potencial    tóxico de una sustancia. </p>     ]]></body>
<body><![CDATA[<p>Debe tenerse en cuenta que la irritación ocular es una forma peculiar de toxicidad,    ya sea accidental o por exposición aguda, donde los eventos que ocurren son    difíciles de reproducir experimentalmente, por lo que resulta esencial seleccionar    una batería de ensayos que involucren todos los eventos que se producen in vivo    para sustituir el ensayo de Draize. Hoy día se han propuesto una amplia gama    de ensayos para remplazar el método in vivo y el reto de los toxicólogos en    los años venideros es superar todas las barreras en beneficio de la salud y    seguridad humana, donde los métodos alternativos encontrarían entonces un lugar    correcto en la toxicología. </p> <h4>Summary </h4>     <p>The eye may be accidentally damaged by many products of daily use. To guarantee    the consumers’ safety it is necessary to estimate the eye irritation potential    of these chemical substances. This estimation is based on the results obtained    in the Draize rabbit eye irritation test. However, the advances attained in    the development of in vitro toxicology have allowed the use of some alternatives    to evaluate the ocular risk. Therefore, a review is made on the different alternative    methods available up to now that make possible the evaluation in one way or    another of the toxic effects at the ocular level. </p>     <p>Subject headings: IRRITANTS/toxicity; COSMETICS/toxicity; EYE/injuries; RABBITS;    DRUG EVALUATION; ANIMALS, LABORATORY. </p> <h4>Referencias bibliográficas </h4> <ol>       <!-- ref --><li> Wallace H. Principles and methods of toxicology. 2 ed. New York: Raven      Press, 1994:188-205. </li>    Y<!-- ref --><li> Balls M, Bothan PA, Spielmann H. The EC (European Comision)/HO (British      Home Office) International calidation study on Alternatives to the Draize      Eye Irritation Test. Toxicol In Vitro 1995;9(6):871-29. </li>    Y<!-- ref --><li> Bruner LH, Shadduck JA, Esex-Sorlie D. Alternative methods for assessing      the effects of chemical on the eye. Dermal and Ocular Toxicology. Fundamental      and Methods, New York: CRC Press Inc, 1991:585-608. </li>    Y<!-- ref --><li>Bruner LH. In vitro toxicity testing. En: Fraizer JM ed. New York: CRC Press      INC,1992:149-190. </li>    Y<!-- ref --><li>Bruner LH, De Silva O, Earl LK, Easty DL, Pape W, Spielmann H. Report of      the COLIPA workshop on mechanism of eye irritation. Altern Lab Animal 1998;26(6):811-30.</li>    Y<!-- ref --><li>Draize JH, Woodard G, Calvery HO. Methods for the study of irritation and      toxicity of substances applied topically To the skin and mucous membranes.      J Pharmacol Experim Therapeutics 1944;22:372-90. </li>    Y<!-- ref --><li>OECD Guideline for Testing of Chemicals: Guideline No. 405: acute eye irritation/corrosion.      OECD Publication Office, París, 1987. </li>    Y<!-- ref --><li> International Organization For Standardization. Draft international standard      ISO/DIC 10 993-10. Biol Eval Med Devices 1992;5:44-7. </li>    Y<!-- ref --><li> York M, Stering W. A critical of the assessment of the eye irritation potential      using the Draize rabbit eye test. J Appl Toxicol 1998;18:233-40. </li>    Y<!-- ref --><li> Balls M, Bergi N, Brune L Curren R, De Silva O, Earl L, et al. Eye irritation      testing: the way forward. The report and recommendations of ECVAM workshop.      Altern Lab Animal 1999;27(1):53-71. </li>    Y<!-- ref --><li>Goldberg AM. Alternative Methods in Toxicology 9. In Vitro Toxicology Tenth      Aniversary Symposium OFCAAT. New York: Mary Ann Liebert, 1993:107-15. </li>    Y<!-- ref --><li>Cornier EM, Hunter JE, Billimer J, Farage MA. The use of clinical and consumer      eye iritation data to evaluate the low volume eye test. J Toxicol Cutan Ocular      Toxicol 1995;14(3):197-205. </li>    Y<!-- ref --><li> Weil C. Study of intra-interlaboratory variability in the result of rabbit      eye and skin irritation test. Toxicol Appl Pharmacol 1985;25(2):139-143. </li>    Y<!-- ref --><li> Bruner LH, Parker RD, Bruce RD. Reducing the number of rabbits in the low      volumen eye test. Fund Appl Toxicol 1992;19:330-335. </li>    Y<!-- ref --><li> Cornier E, Parker R, Henson C, Cruse L, Merrit A, Bruce R. Determination      of the intra-and interlaboratory variability of the low volume eye test and      its statitsical relationship to the Draize test. Fund Appl Toxicol 1994;1:140-61.    </li>    Y<!-- ref --><li> Balls M, Goldberg AM Fentem J.H. Broadhead CL. The Three Rs: The way forward.      ECVAM Worshop Report 11. Altern Lab Animal 1995;23:838-66. </li>    Y<!-- ref --><li>Kojima H, Hanamura A, Miyamoto S, Sato A, Konishi H, Yoshimura I. Evaluation      of seven alternative assays on the main ingredients in cosmetics predictor      of Draize eye irritation scores. Toxicol In Vitro 1995;9(3)333-40. </li>    Y<!-- ref --><li>European Chemical Industry Ecology & Toxicology Centre (ECETOC). Monografía      11. Eye irritation testing. Bruselas. 1988 Actualizado 1996. </li>    Y<li>19. Fente, JH, Archer GEB, Balls M, Botham PA, Curren RD, Earl LK, et al.      The ECVAM International Validation Study on in vitro test for skin corrosivity.      2 Results and Evaluation by Management Team. Toxicol In Vitro 1998;12:483-524.</li>       ]]></body>
<body><![CDATA[<!-- ref --><li> INVITTOX (Data Bank of In Vitro Techniques in Toxicology) Protocol No.      37 Red Blood Cell 1992. </li>    Y<!-- ref --><li> Pape WI, Pfannenbecker U, Argembeaux H, Bracher M, Esdoile DJ, Hagino S,      et al. COLIPA validation project on in vitro eye irritation test for cosmetic      ingredients and finished products: the red blood cell test for the estimation      of acute eye irritation potential. Presents status. Toxicol In Vitro 1999;13:343-54.    </li>    Y<!-- ref --><li> Spielmann H, Liesbsh M, Kalwert S, Moldehaver F, Wirnsberger T, Holzhütter      HG, et al. Results of validation study in Germany on two in vitro alternatives      to the Draize eye irritation test, the HET--CAM test and the 3T3 NRU cytotoxicity      test. Altern Lab Animal 1996;24:741-858. </li>    Y<!-- ref --><li> Gautheron P, Dukic M, Alix D, Sina J. Interlaboratory assessment of bovine      corneal opacity and permeability (BCOP). Toxicol In Vitro 1994;8:381-2.</li>    Y<!-- ref --><li>Luepke NP. Hen´s egg chorioallantoic membrane test for irritation potential.      Food Chem Toxicol 1995;23(2):287-91. </li>    Y]]></body>
<body><![CDATA[<!-- ref --><li> Steiling W, Bracher M, Coutermellont P, De Silva O. The HET-CAM a useful      assay for assessing the eye irritation properties of cosmetics formulations      and ingredientes. Toxicol In Vitro 1999;13:375-84. </li>    Y<!-- ref --><li> Gordon VC. The scientific basis of the Eytex system. Altern Lab Animal      1992;20:313-26. </li>    Y<!-- ref --><li>Francois H. The eye (rabbit/human): measurement parameters in the field      of ocular irritation. Altern Lab Animal 1992;20(3):476-9. </li>    Y</ol>     <p>Recibido: 18 de abril del 2001. Aprobado: 28 de mayo del 2001.     <br>   Lic: Raiza Vega Montalvo. Centro de investigación y Desarrollo de Medicamentos.    Ave. 26 No. 1605 entre Boyeros y Puentes Grandes, municipio Plaza de la Revolución,    Ciudad de La Habana, CP 10600, Cuba. </p>     <p><span class="superscript"><a href="#autor">1 </a></span><a href="#autor">Licenciada    en Ciencias Farmacéuticas. Aspirante a Investigadora.     ]]></body>
<body><![CDATA[<br>   <span class="superscript">2</span> Licenciada en Ciencias Farmacéuticas. </a><a name="cargo"></a></p> <h5 align="right"><a href="farsu301.htm">Indice</a> <a href="far09301.htm">Anterior</a>    <a href="far11301.htm">Siguiente</a></h5>      ]]></body><back>
<ref-list>
<ref id="B1">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Wallace]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<source><![CDATA[Principles and methods of toxicology]]></source>
<year>1994</year>
<edition>2 ed</edition>
<page-range>188-205</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Raven Press]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Balls]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bothan]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Spielmann]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The EC (European Comision)/HO (British Home Office) International calidation study on Alternatives to the Draize Eye Irritation Test]]></article-title>
<source><![CDATA[Toxicol In Vitro]]></source>
<year>1995</year>
<volume>9</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>871-29</page-range></nlm-citation>
</ref>
<ref id="B3">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bruner]]></surname>
<given-names><![CDATA[LH]]></given-names>
</name>
<name>
<surname><![CDATA[Shadduck]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Esex-Sorlie]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<source><![CDATA[Alternative methods for assessing the effects of chemical on the eye. Dermal and Ocular Toxicology: Fundamental and Methods]]></source>
<year>1991</year>
<page-range>585-608</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[CRC Press Inc]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B4">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bruner]]></surname>
<given-names><![CDATA[LH]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[In vitro toxicity testing]]></article-title>
<person-group person-group-type="editor">
<name>
<surname><![CDATA[Fraizer]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
</person-group>
<source><![CDATA[]]></source>
<year>1992</year>
<page-range>149-190</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[CRC Press INC]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bruner]]></surname>
<given-names><![CDATA[LH]]></given-names>
</name>
<name>
<surname><![CDATA[De Silva]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Earl]]></surname>
<given-names><![CDATA[LK]]></given-names>
</name>
<name>
<surname><![CDATA[Easty]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Pape]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Spielmann]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Report of the COLIPA workshop on mechanism of eye irritation]]></article-title>
<source><![CDATA[Altern Lab Animal]]></source>
<year>1998</year>
<volume>26</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>811-30</page-range></nlm-citation>
</ref>
<ref id="B6">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Draize]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Woodard]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Calvery]]></surname>
<given-names><![CDATA[HO]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Methods for the study of irritation and toxicity of substances applied topically To the skin and mucous membranes]]></article-title>
<source><![CDATA[J Pharmacol Experim Therapeutics]]></source>
<year>1944</year>
<volume>22</volume>
<page-range>372-90</page-range></nlm-citation>
</ref>
<ref id="B7">
<nlm-citation citation-type="book">
<source><![CDATA[OECD Guideline for Testing of Chemicals: Guideline No. 405: acute eye irritation/corrosion]]></source>
<year>1987</year>
<publisher-loc><![CDATA[París, ]]></publisher-loc>
<publisher-name><![CDATA[OECD Publication Office]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<nlm-citation citation-type="journal">
<collab>International Organization For Standardization</collab>
<article-title xml:lang="en"><![CDATA[Draft international standard ISO/DIC 10 993-10]]></article-title>
<source><![CDATA[Biol Eval Med Devices]]></source>
<year>1992</year>
<volume>5</volume>
<page-range>44-7</page-range></nlm-citation>
</ref>
<ref id="B9">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[York]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Stering]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[A critical of the assessment of the eye irritation potential using the Draize rabbit eye test]]></article-title>
<source><![CDATA[J Appl Toxicol]]></source>
<year>1998</year>
<volume>18</volume>
<page-range>233-40</page-range></nlm-citation>
</ref>
<ref id="B10">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Balls]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Bergi]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
<name>
<surname><![CDATA[Brune]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Curren]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[De Silva]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Earl]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Eye irritation testing: the way forward: The report and recommendations of ECVAM workshop]]></article-title>
<source><![CDATA[Altern Lab Animal]]></source>
<year>1999</year>
<volume>27</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>53-71</page-range></nlm-citation>
</ref>
<ref id="B11">
<nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
</person-group>
<source><![CDATA[Alternative Methods in Toxicology 9: In Vitro Toxicology Tenth Aniversary Symposium OFCAAT]]></source>
<year>1993</year>
<page-range>107-15</page-range><publisher-loc><![CDATA[New York ]]></publisher-loc>
<publisher-name><![CDATA[Mary Ann Liebert]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cornier]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[Hunter]]></surname>
<given-names><![CDATA[JE]]></given-names>
</name>
<name>
<surname><![CDATA[Billimer]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Farage]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The use of clinical and consumer eye iritation data to evaluate the low volume eye test]]></article-title>
<source><![CDATA[J Toxicol Cutan Ocular Toxicol]]></source>
<year>1995</year>
<volume>14</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>197-205</page-range></nlm-citation>
</ref>
<ref id="B13">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Weil]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Study of intra-interlaboratory variability in the result of rabbit eye and skin irritation test]]></article-title>
<source><![CDATA[Toxicol Appl Pharmacol]]></source>
<year>1985</year>
<volume>25</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>139-143</page-range></nlm-citation>
</ref>
<ref id="B14">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bruner]]></surname>
<given-names><![CDATA[LH]]></given-names>
</name>
<name>
<surname><![CDATA[Parker]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Bruce]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reducing the number of rabbits in the low volumen eye test]]></article-title>
<source><![CDATA[Fund Appl Toxicol]]></source>
<year>1992</year>
<volume>19</volume>
<page-range>330-335</page-range></nlm-citation>
</ref>
<ref id="B15">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Cornier]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Parker]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Henson]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[Cruse]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Merrit]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Bruce]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Determination of the intra-and interlaboratory variability of the low volume eye test and its statitsical relationship to the Draize test]]></article-title>
<source><![CDATA[Fund Appl Toxicol]]></source>
<year>1994</year>
<volume>1</volume>
<page-range>140-61</page-range></nlm-citation>
</ref>
<ref id="B16">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Balls]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Goldberg]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[Fentem]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Broadhead]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The Three Rs:: The way forward. ECVAM Worshop Report 11]]></article-title>
<source><![CDATA[Altern Lab Animal]]></source>
<year>1995</year>
<volume>23</volume>
<page-range>838-66</page-range></nlm-citation>
</ref>
<ref id="B17">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kojima]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Hanamura]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Miyamoto]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Sato]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Konishi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Yoshimura]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Evaluation of seven alternative assays on the main ingredients in cosmetics predictor of Draize eye irritation scores]]></article-title>
<source><![CDATA[Toxicol In Vitro]]></source>
<year>1995</year>
<volume>9</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>333-40</page-range></nlm-citation>
</ref>
<ref id="B18">
<nlm-citation citation-type="">
<collab>European Chemical Industry Ecology & Toxicology Centre (ECETOC)</collab>
<source><![CDATA[Monografía 11: Eye irritation testing]]></source>
<year>1988</year>
<publisher-loc><![CDATA[Bruselas ]]></publisher-loc>
</nlm-citation>
</ref>
<ref id="B19">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fente]]></surname>
<given-names><![CDATA[JH]]></given-names>
</name>
<name>
<surname><![CDATA[Archer]]></surname>
<given-names><![CDATA[GE]]></given-names>
</name>
<name>
<surname><![CDATA[Balls]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Botham]]></surname>
<given-names><![CDATA[PA]]></given-names>
</name>
<name>
<surname><![CDATA[Curren]]></surname>
<given-names><![CDATA[RD]]></given-names>
</name>
<name>
<surname><![CDATA[Earl]]></surname>
<given-names><![CDATA[LK]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The ECVAM International Validation Study on in vitro test for skin corrosivity: 2 Results and Evaluation by Management Team]]></article-title>
<source><![CDATA[Toxicol In Vitro]]></source>
<year>1998</year>
<volume>12</volume>
<page-range>483-524</page-range></nlm-citation>
</ref>
<ref id="B20">
<nlm-citation citation-type="">
<collab>INVITTOX (Data Bank of In Vitro Techniques in Toxicology)</collab>
<source><![CDATA[Protocol No. 37: Red Blood Cell]]></source>
<year>1992</year>
</nlm-citation>
</ref>
<ref id="B21">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Pape]]></surname>
<given-names><![CDATA[WI]]></given-names>
</name>
<name>
<surname><![CDATA[Pfannenbecker]]></surname>
<given-names><![CDATA[U]]></given-names>
</name>
<name>
<surname><![CDATA[Argembeaux]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Bracher]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Esdoile]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Hagino]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[COLIPA validation project on in vitro eye irritation test for cosmetic ingredients and finished products: the red blood cell test for the estimation of acute eye irritation potential]]></article-title>
<source><![CDATA[Presents status. Toxicol In Vitro]]></source>
<year>1999</year>
<volume>13</volume>
<page-range>343-54</page-range></nlm-citation>
</ref>
<ref id="B22">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Spielmann]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Liesbsh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Kalwert]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Moldehaver]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Wirnsberger]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Holzhütter]]></surname>
<given-names><![CDATA[HG]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Results of validation study in Germany on two in vitro alternatives to the Draize eye irritation test, the HET--CAM test and the 3T3 NRU cytotoxicity test]]></article-title>
<source><![CDATA[Altern Lab Animal]]></source>
<year>1996</year>
<volume>24</volume>
<page-range>741-858</page-range></nlm-citation>
</ref>
<ref id="B23">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gautheron]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Dukic]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Alix]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Sina]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Interlaboratory assessment of bovine corneal opacity and permeability (BCOP)]]></article-title>
<source><![CDATA[Toxicol In Vitro]]></source>
<year>1994</year>
<volume>8</volume>
<page-range>381-2</page-range></nlm-citation>
</ref>
<ref id="B24">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Luepke]]></surname>
<given-names><![CDATA[NP]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Hen´s egg chorioallantoic membrane test for irritation potential]]></article-title>
<source><![CDATA[Food Chem Toxicol]]></source>
<year>1995</year>
<volume>23</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>287-91</page-range></nlm-citation>
</ref>
<ref id="B25">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Steiling]]></surname>
<given-names><![CDATA[W]]></given-names>
</name>
<name>
<surname><![CDATA[Bracher]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Coutermellont]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[De Silva]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The HET-CAM a useful assay for assessing the eye irritation properties of cosmetics formulations and ingredientes]]></article-title>
<source><![CDATA[Toxicol In Vitro]]></source>
<year>1999</year>
<volume>13</volume>
<page-range>375-84</page-range></nlm-citation>
</ref>
<ref id="B26">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gordon]]></surname>
<given-names><![CDATA[VC]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The scientific basis of the Eytex system]]></article-title>
<source><![CDATA[Altern Lab Animal]]></source>
<year>1992</year>
<volume>20</volume>
<page-range>313-26</page-range></nlm-citation>
</ref>
<ref id="B27">
<nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Francois]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The eye (rabbit/human): measurement parameters in the field of ocular irritation]]></article-title>
<source><![CDATA[Altern Lab Animal]]></source>
<year>1992</year>
<volume>20</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>476-9</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
