<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>0864-215X</journal-id>
<journal-title><![CDATA[Revista Cubana de Ortopedia y Traumatología]]></journal-title>
<abbrev-journal-title><![CDATA[Rev Cubana Ortop Traumatol]]></abbrev-journal-title>
<issn>0864-215X</issn>
<publisher>
<publisher-name><![CDATA[Editorial Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S0864-215X2007000200006</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Osteosíntesis percutánea de fracturas interarticulares de tibia distal mediante locking compression plate (LCP)]]></article-title>
<article-title xml:lang="fr"><![CDATA[Ostéosynthèse percutanée des fractures intraarticulaires du tibia distal par locking compression plate (LCP)]]></article-title>
<article-title xml:lang="en"><![CDATA[Percutaneous osteosynthesis of intraarticular distal tibia fracture by locking compression plate (LCP)]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Lumbreras Virgós]]></surname>
<given-names><![CDATA[Ruth]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Castro Sauras]]></surname>
<given-names><![CDATA[Ángel]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Modrego Arandia]]></surname>
<given-names><![CDATA[Francisco Javier]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Ballester Giménez]]></surname>
<given-names><![CDATA[Juan José]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Espallargas Doñate]]></surname>
<given-names><![CDATA[Teresa]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Hospital General de Teruel Obispo Polanco  ]]></institution>
<addr-line><![CDATA[Teruel ]]></addr-line>
<country>España</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2007</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2007</year>
</pub-date>
<volume>21</volume>
<numero>2</numero>
<fpage>0</fpage>
<lpage>0</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S0864-215X2007000200006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S0864-215X2007000200006&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S0864-215X2007000200006&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se expuso el caso de un paciente de 34 años con fracturas de ambos pilones tibiales tras accidente de tránsito, al cual se le realizó con carácter de urgencia una estabilización lo más percutánea posible mediante locking compression plate (LCP) para pilón tibial y LCP medial para tibia distal con excelentes resultados. Las fracturas de tibia distal, en especial las fracturas de pilón tibial, suponen un gran desafío para el cirujano ortopédico. El mecanismo de producción suele ser de alta energía por lo que la lesión ósea viene acompañada de gran afectación de partes blandas. Los nuevos implantes permiten aplicar el principio de estabilidad angular además de la posibilidad de fijación percutánea mínimamente invasiva, preservando la vascularización ósea. La orientación de los orificios en LCP medial y la adaptabilidad de la LCP para pilón tibial hacen de estas placas una excelente herramienta.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[The case of a 34-year-old patient with fractures of both tibial pilons after a car accident was presented. An emergency stabilization as percutaneous as possible was performed by locking compression plate (LCP) for tibial pilon and medial LCP for distal tibia with excellent results. The distal tibia fractures suppose a great challenge for the orthopaedic surgeon. The production mechanism is usually of high energy, so the bone injury is accompanied with great affectation of the soft tissues. The new implants allow to apply the angular stability principle, and it also gives the possibility of minimally invasive percutaneous fixation, preserving bone vascularization. The orientation of the orifices in medial LCP and the adaptability of LCP for tibial pilon made of these plates an excellent tool.]]></p></abstract>
<abstract abstract-type="short" xml:lang="fr"><p><![CDATA[Le cas d'un patient âgé de 34 ans atteint des fractures de tous les deux pilons tibiaux, après un accident de la route, et traité en urgence avec succès par une stabilisation le plus percutanée que possible (locking compression plate-LCP) du pilon tibial et LCP médial du tibia distal, est présenté. Les fractures du tibia distal, en particulier les fractures du pilon tibial, sont un défi réel pour le chirurgien orthopédiste. Le mécanisme de survenue de ces fractures est en général d'une très grande énergie, ayant pour effet un grand compromis des parties molles. Les nouveaux implants permettent d'appliquer le principe de stabilisation par plaque angulée, en plus d'une fixation percutanée mini-invasive, protégeant ainsi la vascularisation osseuse. La direction des trous de la LCP médial et l'adaptabilité de la LCP au pilon tibial font de ces plaques un outil excellent.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Tibia distal]]></kwd>
<kwd lng="es"><![CDATA[pilón tibial]]></kwd>
<kwd lng="es"><![CDATA[osteosíntesis percutánea]]></kwd>
<kwd lng="en"><![CDATA[Distal tibia]]></kwd>
<kwd lng="en"><![CDATA[tibial pilon]]></kwd>
<kwd lng="en"><![CDATA[percutaneous osteosynthesis]]></kwd>
<kwd lng="fr"><![CDATA[Tibia distal]]></kwd>
<kwd lng="fr"><![CDATA[pilon tibial]]></kwd>
<kwd lng="fr"><![CDATA[ostéosynthèse percutanée]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <p align="right"><font face="Verdana" size="2"> <b>PRESENTACI&Oacute;N DE CASO    </b></font></p>     <p>&nbsp;</p>     <p><font face="Verdana" size="4"><b>Osteos&iacute;ntesis percut&aacute;nea de    fracturas interarticulares de tibia distal mediante <I>locking compression plate    </I>(LCP) </b> </font></p>     <p>&nbsp;</p>     <p></p>     <p></p>     <p><b><font face="Verdana" size="3">Ost&eacute;osynth&egrave;se percutan&eacute;e    des fractures intraarticulaires du tibia distal par locking compression plate    (LCP) </font></b></p>     <p> </p>     <p> </p>     <p>&nbsp;</p>     ]]></body>
<body><![CDATA[<p>&nbsp; </p>     <p><font size="3"><b><font face="Verdana">Percutaneous osteosynthesis of intraarticular    distal tibia fracture by <i>locking compression plate </i>(LCP) </font></b></font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>Dra. Ruth Lumbreras Virg&oacute;s<SUP>I</SUP>;    Dr. &Aacute;ngel Castro Sauras<SUP>I</SUP>; Dr. Francisco Javier Modrego Arandia<SUP>I</SUP>;    Dr. Juan Jos&eacute; Ballester Gim&eacute;nez<SUP>I</SUP>; Dra. Teresa Espallargas    Do&ntilde;ate</b></font><b><font face="Verdana" size="2"><SUP>I </SUP></font></b></p>     <p><font face="Verdana" size="2"><SUP>I </sup>Especialistas en<SUP> </SUP>Traumatolog&iacute;a    y Cirug&iacute;a Ortop&eacute;dica. Hospital General de Teruel &quot;Obispo    Polanco&quot;. Espa&ntilde;a. </font></p>     <p>&nbsp;</p>     <p>&nbsp;</p> <hr> <font face="Verdana" size="2"><b>RESUMEN </b></font>      <p><font face="Verdana" size="2">Se expuso el caso de un paciente de 34 a&ntilde;os    con fracturas de ambos pilones tibiales tras accidente de tr&aacute;nsito, al    cual se le realiz&oacute; con car&aacute;cter de urgencia una estabilizaci&oacute;n    lo m&aacute;s percut&aacute;nea posible mediante <I>locking compression plate</I>    (LCP) para pil&oacute;n tibial y LCP medial para tibia distal con excelentes    resultados. Las fracturas de tibia distal, en especial las fracturas de pil&oacute;n    tibial, suponen un gran desaf&iacute;o para el cirujano ortop&eacute;dico. El    mecanismo de producci&oacute;n suele ser de alta energ&iacute;a por lo que la    lesi&oacute;n &oacute;sea viene acompa&ntilde;ada de gran afectaci&oacute;n    de partes blandas. Los nuevos implantes permiten aplicar el principio de estabilidad    angular adem&aacute;s de la posibilidad de fijaci&oacute;n percut&aacute;nea    m&iacute;nimamente invasiva, preservando la vascularizaci&oacute;n &oacute;sea.    La orientaci&oacute;n de los orificios en LCP medial y la adaptabilidad de la    LCP para pil&oacute;n tibial hacen de estas placas una excelente herramienta.    </font></p>     <p><font face="Verdana" size="2"><b>Palabras clave</b>: Tibia distal, pil&oacute;n    tibial, osteos&iacute;ntesis percut&aacute;nea. </font></p> <hr> <font face="Verdana" size="2"><b>SUMMARY</b> </font>     ]]></body>
<body><![CDATA[<p> </p>     <p><font face="Verdana" size="2">The case of a 34-year-old patient with fractures    of both<font  color="#ff0000"> </font>tibial pilons after a car accident was presented. An emergency    stabilization as percutaneous as possible was performed by <i>locking compression    plate</i> (LCP) for tibial pilon and medial LCP for distal tibia with excellent    results. The distal tibia fractures suppose a great challenge for the orthopaedic    surgeon. The production mechanism is usually of high energy, so the bone injury    is accompanied with great affectation of the soft tissues. The new implants    allow to apply the angular stability principle, and it also gives the possibility    of minimally invasive percutaneous fixation, preserving bone vascularization.    The orientation of the orifices in medial LCP and the adaptability of LCP for    tibial pilon<font  color="#ff0000"> </font>made of these plates an excellent tool. </font></p>     <p> </p>     <p><font face="Verdana" size="2"><b>Key words</b>: Distal tibia,<font color="#ff0000">    </font>tibial pilon,<font color="#ff0000"> </font>percutaneous osteosynthesis.    </font></p> <hr> <font face="Verdana" size="2"><b>R&Eacute;SUM&Eacute; </b></font>      <p> </p>     <p> </p>     <p><font face="Verdana" size="2">Le cas d'un patient &acirc;g&eacute; de 34 ans    atteint des fractures de tous les deux pilons tibiaux, apr&egrave;s un accident    de la route, et trait&eacute; en urgence avec succ&egrave;s par une stabilisation    le plus percutan&eacute;e que possible (<I>locking compression plate</I>-LCP)    du pilon tibial et LCP m&eacute;dial du tibia distal, est pr&eacute;sent&eacute;.    Les fractures du tibia distal, en particulier les fractures du pilon tibial,    sont un d&eacute;fi r&eacute;el pour le chirurgien orthop&eacute;diste. Le m&eacute;canisme    de survenue de ces fractures est en g&eacute;n&eacute;ral d'une tr&egrave;s    grande &eacute;nergie, ayant pour effet un grand compromis des parties molles.    Les nouveaux implants permettent d'appliquer le principe de stabilisation par    plaque angul&eacute;e, en plus d'une fixation percutan&eacute;e mini-invasive,    prot&eacute;geant ainsi la vascularisation osseuse. La direction des trous de    la LCP m&eacute;dial et l'adaptabilit&eacute; de la LCP au pilon tibial font    de ces plaques un outil excellent. </font></p>     <p> </p>     <p> </p>     <p> </p>     ]]></body>
<body><![CDATA[<p><b><font face="Verdana" size="2">Mots-cl&eacute;s</font></b><font face="Verdana" size="2">:    Tibia distal, pilon tibial, ost&eacute;osynth&egrave;se percutan&eacute;e.</font></p> <hr>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p></p>     <p></p>     <p> </p>     <p> </p>     <p> </p>     <p><font size="2"><b><font face="Verdana">INTRODUCCI&Oacute;N </font></b></font></p>     <p> </p>     ]]></body>
<body><![CDATA[<p><font face="Verdana" size="2">Las fracturas de tibia distal, en especial las    fracturas de pil&oacute;n tibial, suponen un gran desaf&iacute;o para el cirujano    ortop&eacute;dico. Habitualmente est&aacute;n producidas por un mecanismo de    alta energ&iacute;a (compresi&oacute;n), por lo que la lesi&oacute;n &oacute;sea    viene acompa&ntilde;ada de gran afectaci&oacute;n de partes blandas.<SUP>1</SUP>    Se han desarrollado nuevos implantes para tibia distal de cuarta generaci&oacute;n    que permiten aplicar el principio de estabilidad angular a la fijaci&oacute;n    que se obten&iacute;a con los implantes tradicionales. Adem&aacute;s, dan la    posibilidad de fijaci&oacute;n percut&aacute;nea m&iacute;nimamente invasiva    en casos en los que se puede realizar una reducci&oacute;n indirecta, con la    consecuente preservaci&oacute;n de la vascularizaci&oacute;n &oacute;sea.<SUP>1-3</SUP>    </font></p>     <p>&nbsp;</p>     <p> </p>     <p><font face="Verdana" size="2"><b>CASO CL&Iacute;NICO</b> </font></p>     <p> </p>     <p><font face="Verdana" size="2">Paciente var&oacute;n de 34 a&ntilde;os remitido    al centro tras sufrir accidente de tr&aacute;nsito con choque frontal y atrapamiento    en veh&iacute;culo de extremidades inferiores. </font></p>     <p><font face="Verdana" size="2">En el servicio de urgencias se diagnostican las    lesiones siguientes: </font></p>     <p> </p>     <p><font face="Verdana" size="2">- Herida inciso-contusa en ment&oacute;n.    <br>   </font><font face="Verdana" size="2">- Fracturas conminutas de ambos pilones    tibiales y peron&eacute; (figs. <a href="/img/revistas/ort/v21n2/f0106207.JPG">1</a>    y <a href="/img/revistas/ort/v21n2/f0206207.JPG">2</a>): </font></p>     
]]></body>
<body><![CDATA[<p> </p>     <p><font face="Verdana" size="2">&#183; Derecho: fractura conminuta de pil&oacute;n    tibial derecho abierta grado I de Gustilo    <br>   </font><font face="Verdana" size="2">&#183; Izquierdo: fractura conminuta de    pil&oacute;n tibial izquierdo. </font></p>     <p> </p>     <p><font face="Verdana" size="2">Para su tratamiento se intervino con car&aacute;cter    de urgencia y se realiz&oacute; osteos&iacute;ntesis de manera lo m&aacute;s    percut&aacute;nea posible utilizando los implantes siguientes: </font></p>     <p> </p>     <p><font face="Verdana" size="2">&#183; Fractura de pil&oacute;n tibial derecho:    estabilizaci&oacute;n con placa LCP para tibia distal y placa de 1/3 de tubo    de 6 orificios para fractura de peron&eacute;.    <br>   </font><font face="Verdana" size="2">&#183; Fractura de pil&oacute;n tibial    izquierdo: estabilizaci&oacute;n con placa LCP para pil&oacute;n tibial de 9    orificios con aporte de injertos ant&oacute;logos de cresta iliaca y osteos&iacute;ntesis    de peron&eacute; mediante placa de 1/3 de tubo de 6 orificios. </font></p>     <p> </p>     <p><font face="Verdana" size="2">Al a&ntilde;o ambas fracturas est&aacute;n consolidadas,    permiten al paciente la deambulaci&oacute;n sin cl&iacute;nica de dolor y sin    precisar dispositivo ortop&eacute;dico alguno (<a href="/img/revistas/ort/v21n2/f0306207.JPG">fig.    3</a>). </font></p>     
]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p></p>     <p></p>     <p> </p>     <p><font size="2"><b><font face="Verdana">DISCUSI&Oacute;N </font></b></font></p>     <p> </p>     <p><font face="Verdana" size="2">La utilizaci&oacute;n de manera percut&aacute;nea    de estos implantes tan solo es posible en aquellos casos en los que se puede    realizar una reducci&oacute;n indirecta de la fractura.<SUP>2,3</SUP></font></p>     <p><font face="Verdana" size="2">Cuando se tenga que demorar el tratamiento por    causa de la gran afectaci&oacute;n de partes blandas o estado general del paciente,    se aconseja la utilizaci&oacute;n de una fijaci&oacute;n externa como tratamiento    inicial que luego es reconvertible a fijaci&oacute;n interna con placa LCP.<SUP>2</SUP>    </font></p>     <p><font face="Verdana" size="2">La orientaci&oacute;n de los orificios en LCP    medial y la adaptabilidad de la LCP para pil&oacute;n tibial hacen de estas    placas una excelente herramienta. </font></p>     <p> </p>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p><font face="Verdana" size="2"><b>REFERENCIAS BIBLIOGR&Aacute;FICAS <font size="3">    </font></b></font></p>     <p> </p>     <!-- ref --><p><font face="Verdana" size="2">1. Helfet DL, Suk M. Minimally invasive percutaneus    plate osteosynthesis fractures of the distal tibia. Instr Course Lext. 2004;53:471-5.    </font><!-- ref --><p><font face="Verdana" size="2">2. Redfern DJ, Syed SU, Davies SJ. Fractures    of the distal tibia: minimally invasive plate osteosynthesis. Injury. 2004;35(6):615-20.    </font><!-- ref --><p><font face="Verdana" size="2">3. Toms AD, McMurtie A, Maffulli N. Percutaneus    plating of the distal tibia. J Foot Ankle Surg. 2004;43(3):199-203. </font><p>&nbsp;</p>     <p>&nbsp;</p>     <p> </p>     <p><font face="Verdana" size="2">Recibido: 9 de octubre de 2007.    ]]></body>
<body><![CDATA[<br>   </font><font face="Verdana" size="2">Aprobado: 8 de noviembre de 2007. </font></p>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p> </p>     <p><font face="Verdana" size="2">Dra. <I>Ruth Elisa Lumbreras Virg&oacute;s. </I>Hospital    General de Teruel &quot;Obispo Polanco&quot;. Avenida Ruiz Jarabe, Teruel, Espa&ntilde;a.    C&oacute;digo Postal 44002. Tel&eacute;f.: 0034-654701103. Correo electr&oacute;nico:    <a href="mailto:ruthlumbreras@hotmail.com">ruthlumbreras@hotmail.com </a></font></p>      ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Helfet]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Suk]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Minimally invasive percutaneus plate osteosynthesis fractures of the distal tibia]]></article-title>
<source><![CDATA[Instr Course Lext.]]></source>
<year>2004</year>
<volume>53</volume>
<page-range>471-5</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Redfern]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Syed]]></surname>
<given-names><![CDATA[SU]]></given-names>
</name>
<name>
<surname><![CDATA[Davies]]></surname>
<given-names><![CDATA[SJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Fractures of the distal tibia: minimally invasive plate osteosynthesis]]></article-title>
<source><![CDATA[Injury.]]></source>
<year>2004</year>
<volume>35</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>615-20</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Toms]]></surname>
<given-names><![CDATA[AD]]></given-names>
</name>
<name>
<surname><![CDATA[McMurtie]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Maffulli]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Percutaneus plating of the distal tibia]]></article-title>
<source><![CDATA[J Foot Ankle Surg.]]></source>
<year>2004</year>
<volume>43</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>199-203</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>