<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1029-3019</journal-id>
<journal-title><![CDATA[MEDISAN]]></journal-title>
<abbrev-journal-title><![CDATA[MEDISAN]]></abbrev-journal-title>
<issn>1029-3019</issn>
<publisher>
<publisher-name><![CDATA[Centro Provincial de Información de Ciencias Médicas]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1029-30192016000700010</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Insuficiencia de convergencia: opciones terapéuticas en dos féminas]]></article-title>
<article-title xml:lang="en"><![CDATA[Convergence inadequacy: therapeutic options in two women]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Hernández Marrero]]></surname>
<given-names><![CDATA[Xiomara Margarita]]></given-names>
</name>
<xref ref-type="aff" rid="A01"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Chiang Infante]]></surname>
<given-names><![CDATA[Walquiria]]></given-names>
</name>
<xref ref-type="aff" rid="A02"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fabars Savigne]]></surname>
<given-names><![CDATA[Silveria]]></given-names>
</name>
<xref ref-type="aff" rid="A03"/>
</contrib>
</contrib-group>
<aff id="A01">
<institution><![CDATA[,Universidad de Ciencias Médicas Facultad de Enfermería y Tecnología de la Salud Dr. Juan Manuel Páez Inchausti ]]></institution>
<addr-line><![CDATA[Santiago de Cuba ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="A02">
<institution><![CDATA[,Universidad de Ciencias Médicas Policlínico Docente José Martí Pérez ]]></institution>
<addr-line><![CDATA[Santiago de Cuba ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="A03">
<institution><![CDATA[,Universidad de Ciencias Médicas Hospital Infantil Docente Sur Dr. Antonio María Béguez César ]]></institution>
<addr-line><![CDATA[Santiago de Cuba ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>07</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>07</month>
<year>2016</year>
</pub-date>
<volume>20</volume>
<numero>7</numero>
<fpage>938</fpage>
<lpage>942</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1029-30192016000700010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1029-30192016000700010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1029-30192016000700010&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Se presentan 2 casos clínicos de féminas de 49 y 25 años, que acudieron a la consulta de Optometría en la Facultad de Enfermería y Tecnología de la Salud "Dr. Juan Manuel Páez Inchausti" de Santiago de Cuba, por presentar marcado cansancio visual durante el trabajo prolongado e intolerancia a la nueva corrección óptica. Se efectuó una evaluación optométrica integral, que mostró en ambos casos una insuficiencia de convergencia. Por las características de las pacientes, se decidió indicar prisma inducido por descentración del centro óptico en la que presentaba presbicia, y continuar la adaptación de la nueva corrección óptica, además de ejercicios de convergencia, en la afectada más joven. Con estos procedimientos se eliminaron los síntomas en ellas]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Two case reports of 49 and 25 years women are presented that went to the Optometry Service of "Dr. Juan Manuel Páez Inchausti" Nursing and Health Technology Faculty in Santiago de Cuba, due to a marked visual fatigue during the lingering work and intolerance to the new optic correction. A comprehensive optometric evaluation was made that showed in both cases a convergence inadequacy. Due to the characteristics of the patients, it was decided to indicate prism induced by unfocused optic center in the one presenting presbyopia, and to continue the adaptation of the new optic correction, besides convergence exercises, in the younger affected patient. With these procedures the symptoms were eliminated in them]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[insuficiencia de convergencia]]></kwd>
<kwd lng="es"><![CDATA[ejercicios de convergencia]]></kwd>
<kwd lng="es"><![CDATA[inducción de prismas]]></kwd>
<kwd lng="es"><![CDATA[consulta de Optometría]]></kwd>
<kwd lng="en"><![CDATA[convergence inadequacy]]></kwd>
<kwd lng="en"><![CDATA[convergence exercises]]></kwd>
<kwd lng="en"><![CDATA[prisms induction]]></kwd>
<kwd lng="en"><![CDATA[Optometry Service]]></kwd>
</kwd-group>
</article-meta>
</front><body><![CDATA[ <P  ALIGN="RIGHT"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>CASO CL&Iacute;NICO </B></font>     <p>&nbsp;</p>     <p>&nbsp;</p>     <P><font size="2"><b><font size="4" face="Verdana, Arial, Helvetica, sans-serif">Insuficiencia de convergencia: opciones terap&eacute;uticas en dos f&eacute;minas </font>   </b> </font>     <P ALIGN="JUSTIFY">     <P ALIGN="JUSTIFY"><font size="2"><b><font size="3" face="Verdana, Arial, Helvetica, sans-serif">Convergence inadequacy: therapeutic options in two women     </font>   </b>   </font>     <p>&nbsp;</p>     <p>&nbsp;</p>         <P><font size="2"><b><font face="Verdana, Arial, Helvetica, sans-serif">Lic. Xiomara Margarita Hern&aacute;ndez              Marrero,<SUP>I</SUP> Lic. Walquiria Chiang              Infante<SUP>II</SUP> y Lic. Silveria Fabars        Savigne<SUP>III</SUP></font></b></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><SUP>I</SUP> Facultad de Enfermer&iacute;a y Tecnolog&iacute;a de la Salud &quot;Dr. Juan Manuel P&aacute;ez    Inchausti&quot;, Universidad de Ciencias M&eacute;dicas, Santiago de Cuba, Cuba.    ]]></body>
<body><![CDATA[<br> </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><SUP>II</SUP> Policl&iacute;nico Docente &quot;Jos&eacute; Mart&iacute; P&eacute;rez&quot;, Universidad de Ciencias M&eacute;dicas, Santiago de    Cuba, Cuba.    <br> </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><SUP>III</SUP> Hospital Infantil Docente Sur &quot;Dr. Antonio Mar&iacute;a B&eacute;guez C&eacute;sar&quot;, Universidad de    Ciencias M&eacute;dicas, Santiago de Cuba, Cuba. </font>     <p>&nbsp;</p>     <p>&nbsp;</p> <hr>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>RESUMEN</B></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se presentan 2 casos cl&iacute;nicos de f&eacute;minas de 49 y 25 a&ntilde;os, que acudieron a la consulta      de Optometr&iacute;a en la Facultad de Enfermer&iacute;a y Tecnolog&iacute;a de la Salud &quot;Dr. Juan Manuel      P&aacute;ez Inchausti&quot; de Santiago de Cuba, por presentar marcado cansancio visual durante el      trabajo prolongado e intolerancia a la nueva correcci&oacute;n &oacute;ptica.  Se efectu&oacute; una      evaluaci&oacute;n optom&eacute;trica integral, que mostr&oacute; en ambos casos una insuficiencia de convergencia.  Por      las caracter&iacute;sticas de las pacientes, se decidi&oacute; indicar prisma inducido por descentraci&oacute;n      del centro &oacute;ptico en la que presentaba presbicia, y continuar la adaptaci&oacute;n de la      nueva correcci&oacute;n &oacute;ptica, adem&aacute;s de ejercicios de convergencia, en la afectada m&aacute;s joven.       Con estos procedimientos se eliminaron los s&iacute;ntomas en ellas.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>Palabras clave</B>: insuficiencia de convergencia, ejercicios de convergencia, inducci&oacute;n        de prismas, consulta de Optometr&iacute;a. </font> <hr>         <P ALIGN="JUSTIFY"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>ABSTRACT</B></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Two case reports of 49 and 25 years women are presented that went to the        Optometry Service of &quot;Dr. Juan Manuel P&aacute;ez Inchausti&quot; Nursing and Health Technology Faculty        in Santiago de Cuba, due to a marked visual fatigue during the lingering work and intolerance        to the new optic correction.  A comprehensive optometric evaluation was made that showed        in both cases a convergence inadequacy.  Due to the characteristics of the patients, it        was decided to indicate prism induced by unfocused optic center in the one        presenting presbyopia, and to continue the adaptation of the new optic correction,        besides convergence exercises, in the younger affected patient.  With these procedures        the symptoms were eliminated in them.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>Key words</B>: convergence inadequacy, convergence exercises, prisms induction,        Optometry Service.                    </font>     <hr>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>     <p>&nbsp;</p>         <P><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>INTRODUCCI&Oacute;N</B></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La convergencia es la posici&oacute;n relativa de los ejes visuales cuando se cruzan en un        punto pr&oacute;ximo de fijaci&oacute;n; tambi&eacute;n representa el movimiento de los ejes al modificar la        fijaci&oacute;n desde un punto determinado a otro m&aacute;s pr&oacute;ximo.  Esta se produce como un acto reflejo        para mantener la visi&oacute;n binocular        normal.<SUP>1</SUP></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Ahora bien, la insuficiencia de convergencia (IC) ha sido determinada como uno de        los problemas de la visi&oacute;n binocular m&aacute;s comunes en la pr&aacute;ctica optom&eacute;trica diaria.  Se        ha definido como la inhabilidad para obtener o mantener una convergencia adecuada        sin esfuerzo.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los s&iacute;ntomas comunes de la IC incluyen: astenopia, tensi&oacute;n ocular, cefalea, visi&oacute;n        borrosa, diplop&iacute;a, somnolencia, dificultad para la concentraci&oacute;n, movimiento del texto al leer y        p&eacute;rdida de comprensi&oacute;n despu&eacute;s de cortos per&iacute;odos de lectura o realizaci&oacute;n de actividades de        cerca; otros s&iacute;ntomas asociados son: quemaz&oacute;n, lagrimeo y diplop&iacute;a        constante.<SUP>2</SUP> En pacientes asintom&aacute;ticos es importante indagar si el paciente evita las actividades que impliquen        visi&oacute;n pr&oacute;xima o se tapa un ojo mientras lee, porque puede estar suprimiendo la visi&oacute;n de un        ojo para evitar molestias.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">La IC interfiriere con la lectura y el trabajo que requiere la visi&oacute;n de cerca, con un        impacto negativo en la calidad de vida de quienes la padecen, incluso existen estudios en los que        se ha encontrado una gran relaci&oacute;n entre las anomal&iacute;as binoculares y los trastornos de        atenci&oacute;n e hiperactividad en ni&ntilde;os con edad escolar.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En la bibliograf&iacute;a sobre el        tema<SUP>3</SUP> se indican como signos cl&iacute;nicos de la IC: punto pr&oacute;ximo        de convergencia (PPC) alejado, mayor exoforia de cerca que de lejos, relaci&oacute;n        acomodaci&oacute;n convergencia (AC/A) bajo, baja acomodaci&oacute;n relativa positiva (ARP) o reservas        fusionales positivas disminuidas o insuficientes para el tama&ntilde;o de la exoforia, exceso de        acomodaci&oacute;n en visi&oacute;n pr&oacute;xima (VP) y alteraci&oacute;n en la facilidad de vergencias para la base externa.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Asimismo, la causa de la IC aislada, no relacionada con trauma o enfermedad neurol&oacute;gica,        no ha sido completamente determinada.  Se cree que la IC primaria es causada por        un desequilibrio de los movimientos de los ojos en las vergencias, que puede ser innato o        de causa adquirida.<SUP>4</SUP></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Aunque no existe un consenso un&aacute;nime respecto al tratamiento m&aacute;s efectivo para los        pacientes con insuficiencia de convergencia, los procedimientos no quir&uacute;rgicos son los m&aacute;s        utilizados por oftalm&oacute;logos y optometristas; rara vez se practican las operaciones debido a        su car&aacute;cter invasivo y sus complicaciones potenciales. </font>     ]]></body>
<body><![CDATA[<p>&nbsp;</p>        <font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B><font size="3">CASOS CL&Iacute;NICOS</font></B></font>     <P><font size="3"><b><font face="Verdana, Arial, Helvetica, sans-serif">Caso 1</font></b></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se describe el caso de una paciente de 49 a&ntilde;os de edad, color de la piel mestizo, con        procedencia urbana y estilo de vida bueno, quien acudi&oacute; a consulta de Optometr&iacute;a en la        Facultad de Enfermer&iacute;a y Tecnolog&iacute;a de la Salud &quot;Dr. Juan Manuel P&aacute;ez Inchausti&quot; de Santiago        de Cuba, por presentar marcado cansancio visual durante el trabajo prolongado que requer&iacute;a        la visi&oacute;n de cerca, a&uacute;n con la correcci&oacute;n &oacute;ptica adecuada; adem&aacute;s de cefalea frontal,      dolor ocular y lagrimeo.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Como antecedentes patol&oacute;gicos personales, la paciente refiri&oacute; padecer neuropat&iacute;a        e hipertensi&oacute;n arterial, as&iacute; como neuritis &oacute;ptica anterior (papilitis), y entre los        antecedentes familiares, la madre presentaba diabetes <I>mellitus</I> y el padre hipertensi&oacute;n arterial.         Asimismo, consum&iacute;a caf&eacute; (2 tazas al d&iacute;a) y cigarros (aproximadamente 7 al d&iacute;a) como h&aacute;bitos t&oacute;xicos.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Al concluir la anamnesis, se realizaron estudios optom&eacute;trico, oftalmol&oacute;gico y del estado de        la visi&oacute;n binocular:</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Examen ocular: normal    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Movimientos oculares: normales    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Test de oclusi&oacute;n alternante: visi&oacute;n lejana (VL): ortoforia, visi&oacute;n cercana (VC): exoforia    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Lensometr&iacute;a: ambos ojos (A/O) plano, adici&oacute;n (ADD) 1.50    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Dominancia ocular: directa derecha    ]]></body>
<body><![CDATA[<br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Distancia pupilar: ojo derecho (OD) 30 mm, ojo izquierdo (OI) 30 mm    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Agudeza visual (A/V):</font><table border="0" cellspacing="0" cellpadding="0">       <tr>         <td width="114" valign="top"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149; Lejos</font></td>         <td width="150" valign="top"><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149; Cerca</font>      </td>       </tr>       <tr>         <td width="114" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A/V    OD: 1.00</font></p></td>         <td width="150" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A/V    A/O J<SUP>3</SUP></font></p></td>       </tr>       <tr>         <td width="114" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">S/C    OI: 1.00</font></p></td>         <td width="150" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">S/C</font></p></td>       </tr>     </table>       <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;     Examen subjetivo </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Refracci&oacute;n din&aacute;mica: A/O natural (1.0), ADD +1,75 J<SUP>1</SUP></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;    PPC: 22 cm, supresi&oacute;n OD</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;     Diagn&oacute;stico: presbicia e insuficiencia de convergencia</font>     ]]></body>
<body><![CDATA[<P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;     Tratamiento: correcci&oacute;n &oacute;ptica de cerca, A/O +1.75 esf&eacute;rico y descentrar 2 mm la        lente del OD (OD 28 mm, OI 30 mm) </font>     <p>&nbsp;</p>          <P><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>Caso 2</B></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se trata de una paciente de 25 a&ntilde;os de edad, color de la piel mestizo, con        procedencia urbana, ocupaci&oacute;n inform&aacute;tica y estilo de vida bueno, que acudi&oacute; a la consulta de        Optometr&iacute;a en la Facultad de Enfermer&iacute;a y Tecnolog&iacute;a, mencionada previamente, por        presentar intolerancia a la nueva correcci&oacute;n &oacute;ptica, a lo cual refer&iacute;a que ve&iacute;a mejor, pero con        mucha incomodidad.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">No se&ntilde;al&oacute; antecedentes patol&oacute;gicos personales ni familiares relevantes.  Como        h&aacute;bitos t&oacute;xicos refiri&oacute; que consum&iacute;a caf&eacute; y ocasionalmente alcohol.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Luego de efectuada la anamnesis, se realizaron estudios optom&eacute;trico, oftalmol&oacute;gico y        del estado de la visi&oacute;n binocular:</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Examen ocular: normal    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Movimientos oculares: normales    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Lensometr&iacute;a 1 (correcci&oacute;n inicial):    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">OD: + 0.50 - 1.00 x 70    ]]></body>
<body><![CDATA[<br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">OI: + 0.50 - 125 x 100    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Distancia focal: 65 mm</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Lensometr&iacute;a 2 (correcci&oacute;n indicada):    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">OD: + 0.50 - 150 x 70    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">OI: + 0.50 - 2.00 x 100    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Distancia focal: 70 mm    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Dominancia ocular: directa derecha    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Distancia pupilar: 70 mm    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Test de oclusi&oacute;n alternante: VL: 2.5      &Delta;E, VC 10.00 &Delta;X    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     AA: 6.66 D (m&eacute;todo de acercamiento para PP y comparaci&oacute;n de los resultados por tabla        de Donders)    ]]></body>
<body><![CDATA[<br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Acomodaci&oacute;n relativa negativa/acomodaci&oacute;n relativa        positiva: +2.00/-2.00    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Agudeza visual:       </font> <table border="0" cellspacing="0" cellpadding="0">       <tr>         <td width="99" valign="top"><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> &#149; Lejos</font>        </td>         <td width="124" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>&nbsp;</strong></font></p></td>         <td width="190" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><strong>&nbsp;</strong></font></p></td>       </tr>       <tr>         <td width="99" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A/V OD 08<SUP>-1</SUP> </font></p></td>         <td width="124" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A/V (1) OD 1.0<SUP>-2</SUP>  </font></p></td>         <td width="190" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">A/V (2) OD 1.0 </font></p></td>       </tr>       <tr>         <td width="99" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">S/C    OI 05<SUP>-1</SUP>  </font></p></td>         <td width="124" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">C/C    OI 10<SUP>-2</SUP> </font></p></td>         <td width="190" valign="top">    <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">C/C    OI 1.0 </font></p></td>       </tr> </table>             ]]></body>
<body><![CDATA[<P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;     Examen subjetivo </font>         <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Refracci&oacute;n din&aacute;mica: OD + 0.50 - 1.50 x 70 (1.0), OI + 0.50 - 200 x 100 (1.0)</font>         <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;     PPC: sin filtro rojo 15/19 cm, con filtro rojo 22/25 cm.</font>         <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;    Diagn&oacute;stico: astigmatismo mixto e insuficiencia de convergencia.</font>         <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">&#149;    Tratamiento: correcci&oacute;n &oacute;ptica, ejercicios de convergencia (acercamiento del l&aacute;piz)        e higiene visual. </font>     <p>&nbsp;</p>         <P><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>COMENTARIOS</B></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En el primer caso descrito, despu&eacute;s de realizados los estudios correspondientes a la        paciente, se diagnostic&oacute; adem&aacute;s de presbicia una insuficiencia de convergencia, que al realizar        el m&eacute;todo diagn&oacute;stico de PPC suprim&iacute;a el OD (ojo dominante).</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Teniendo en cuenta que las gafas de lectura con uso de prisma de base interna, pueden        ser un tratamiento efectivo en los pacientes con presbicia que presenten insuficiencia        de convergencia sintom&aacute;tica,<SUP>5</SUP> este efecto se puede lograr tambi&eacute;n a trav&eacute;s de la inducci&oacute;n        de un prisma por descentraci&oacute;n del centro &oacute;ptico de la lente.  En este caso se        determin&oacute; disminuir la distancia pupilar (DP) del OD 2 mm, para provocar de esta manera un        efecto prism&aacute;tico, pues para cualquier otro punto fuera del centro &oacute;ptico, las lentes        oft&aacute;lmicas poseen una funci&oacute;n an&aacute;loga al de un prisma, al desv&iacute;a la        luz.<SUP>6</SUP></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El procedimiento se realiz&oacute; a trav&eacute;s del m&eacute;todo de tanteo, utilizando la armadura de prueba.        Al aplicar la f&oacute;rmula de Prentice [&Delta; = d (cm)        P], se observ&oacute; que se hab&iacute;a introducido        un efecto prism&aacute;tico de 0.35 &Delta; en la base interna, con lo cual se logr&oacute; mejorar la        funcionalidad de la visi&oacute;n binocular de la paciente y se eliminaron los s&iacute;ntomas.</font>     ]]></body>
<body><![CDATA[<P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Respecto al segundo caso presentado, al realizar los estudios para determinar las        posibles causas de la intolerancia a la nueva correcci&oacute;n &oacute;ptica, se diagnostic&oacute; astigmatismo mixto        e insuficiencia de convergencia pura, y tanto la amplitud de acomodaci&oacute;n como la        acomodaci&oacute;n relativa negativa y positiva, se encontraban dentro de los l&iacute;mites normales, por lo que        se descart&oacute; la posibilidad de un exceso, que normalmente aparece por un redundante uso de        la convergencia acomodativa para intentar suplir una inadecuada convergencia        fusional positiva.<SUP>7</SUP></font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Se pudo comprobar que tanto la correcci&oacute;n &oacute;ptica como la DP coincid&iacute;an con la indicada,        de manera que inicialmente se atribuy&oacute; la intolerancia solamente a la IC, pero no se        justificaba el hecho de que con la correcci&oacute;n anterior -- aunque el rendimiento visual era        ligeramente menor -- sintiera plena comodidad.  Por ello se midi&oacute; la distancia focal de estas gafas y        se detect&oacute; que se hab&iacute;a modificado (de manera no intencional) la DP en 5 mm, lo que indujo        un prisma por descentraci&oacute;n.  Esto permiti&oacute; alinear artificialmente los ojos durante la lectura        y de esa forma evitar los s&iacute;ntomas provocados por la IC; sin embargo, es de suma        importancia se&ntilde;alar que a trav&eacute;s de este mecanismo no se mejora la convergencia.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Teniendo en cuenta que la insuficiencia de convergencia es uno de los problemas        visuales con mejor pron&oacute;stico en una terapia        visual,<SUP>7</SUP> que la paciente del segundo caso a&uacute;n era        joven, y que los ejercicios de convergencia constituyen el tratamiento prescrito com&uacute;nmente        por oftalm&oacute;logos y optometristas, por ser f&aacute;cil, libre de costo y efectivo para estos        pacientes;<SUP>8</SUP> se elabor&oacute; un plan que inclu&iacute;a: </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Continuar el proceso de adaptaci&oacute;n de la nueva correcci&oacute;n.    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Ejercicios para la casa: acercamiento del l&aacute;piz.    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">-     Higiene visual: realizaci&oacute;n de descansos sistem&aacute;ticos (mirar a lo lejos) durante las        tareas que implican la visi&oacute;n de cerca, fundamentalmente en el ordenador.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">En 3 semanas se logr&oacute; usar las gafas a tiempo completo con comodidad, aunque se indic&oacute;      la continuaci&oacute;n del tratamiento hasta finalizar los 3 meses, para garantizar la estabilidad de        las funciones vergenciales y la disminuci&oacute;n del PPC.</font>     <p>&nbsp;</p>         <P><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>REFERENCIAS BIBLIOGR&Aacute;FICAS</B></font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">1.     Gonz&aacute;lez Blanco F, Mu&ntilde;oz G&oacute;mez S, Mu&ntilde;oz Sanz MA, Sanz Fern&aacute;ndez JC.  La        convergencia acomodativa, comparaci&oacute;n entre dos t&eacute;cnicas de medida. Archivos        Optom&eacute;tricos. 1998; 2(2): 134-43.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">2.     Molina NP, Forero Mora C. Insuficiencia de convergencia.  Ciencia &amp; Tecnolog&iacute;a Salud        Visual Ocular. 2010; 8(2): 91-102.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">3.     Garc&iacute;a Valldecabres M.  Insuficiencia de convergencia y d&eacute;ficit de atenci&oacute;n: A        prop&oacute;sito de un caso.  Gaceta &Oacute;ptica. 2008; (430): 18-22.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">4.     Hern&aacute;ndez SL, Hern&aacute;ndez RL, Pons CL, M&eacute;ndez ST, Dorrego OM, Infantes AL.        Consideraciones actuales en la insuficiencia de convergencia.  Rev Cubana Oftalmol. 2013        [citado 23 Jul 2014]; 26.  Disponible en:<a href="http://www.revoftalmologia.sld.cu/index.php /oftalmologia/article/view/222/html" target="_blank"> <U><FONT  COLOR="#0000ff">http://www.revoftalmologia.sld.cu/index.php/oftalmologia/article/view/222/html</FONT></U></a></font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">5.     Scheiman M, Gwiazda J, Li T.  Non-surgical interventions for convergente insufficiency.        Cochrane Database of Systematic Reviews. 2011 [citado 1 Jul 2014]; (3).  Disponible        en: <U><FONT COLOR="#0000ff"><a href="http://onlinelibrary.wiley.com/doi/10.1002/14651858.CD006768.pub2/full" target="_blank">http://onlinelibrary.wiley.com/doi/10.1002/14651858.CD006768.pub2/full</a></FONT></U></font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">6.     Salvado Arques J, Fransoy Bel M.  Tecnolog&iacute;a &oacute;ptica: lentes oft&aacute;lmicas, dise&ntilde;o y        adaptaci&oacute;n.  Barcelona: Ediciones UPC; 2001.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">7.     Borr&aacute;s Garc&iacute;a MR, Ondategui Parra JC, Pacheco Cutillas M, Varon M, S&aacute;nchez E,       Gispets J. Visi&oacute;n binocular. Diagn&oacute;stico y tratamiento.  Barcelona: Edicions UPC; 1996.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">8.     Kim KM, Chun BY.  Effectiveness of home-based pencil push-ups (HBPP) for patients        with symptomatic convergence insufficiency.  Korean J Ophthalmol. 2011; 25(3): 185-8.         </font>     <p>&nbsp;</p>     <p>&nbsp;</p>         <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Recibido: 30 de marzo de 2015.    <br>     </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Aprobado: 16 de febrero de 2016.     </font>     <p>&nbsp;</p>     <p>&nbsp;</p>         <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><I>Xiomara Margarita Hern&aacute;ndez        Marrero</I>.  Facultad de Enfermer&iacute;a-Tecnolog&iacute;a de la Salud      &quot;Dr. Juan Manuel P&aacute;ez Inchausti&quot;, km 2 &#189; y Autopista, Carretera de El Caney, Santiago de        Cuba, Cuba.  Correo electr&oacute;nico:<a href="mailto:xiomara@fts.scu.sld.cu">xiomara@fts.scu.sld.cu</a></font>     ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[González Blanco]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz Gómez]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Muñoz Sanz]]></surname>
<given-names><![CDATA[MA]]></given-names>
</name>
<name>
<surname><![CDATA[Sanz Fernández]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[La convergencia acomodativa, comparación entre dos técnicas de medida]]></article-title>
<source><![CDATA[Archivos Optométricos.]]></source>
<year>1998</year>
<volume>2</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>134-43</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Molina]]></surname>
<given-names><![CDATA[NP]]></given-names>
</name>
<name>
<surname><![CDATA[Forero Mora]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Insuficiencia de convergencia]]></article-title>
<source><![CDATA[Ciencia & Tecnología Salud Visual Ocular]]></source>
<year>2010</year>
<volume>8</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>91-102</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[García Valldecabres]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Insuficiencia de convergencia y déficit de atención: A propósito de un caso]]></article-title>
<source><![CDATA[Gaceta Óptica]]></source>
<year>2008</year>
<numero>430</numero>
<issue>430</issue>
<page-range>18-22</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[SL]]></given-names>
</name>
<name>
<surname><![CDATA[Hernández]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
<name>
<surname><![CDATA[Pons]]></surname>
<given-names><![CDATA[CL]]></given-names>
</name>
<name>
<surname><![CDATA[Méndez]]></surname>
<given-names><![CDATA[ST]]></given-names>
</name>
<name>
<surname><![CDATA[Dorrego]]></surname>
<given-names><![CDATA[OM]]></given-names>
</name>
<name>
<surname><![CDATA[Infantes]]></surname>
<given-names><![CDATA[AL]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Consideraciones actuales en la insuficiencia de convergencia]]></article-title>
<source><![CDATA[Rev Cubana Oftalmol]]></source>
<year>2013</year>
<volume>26</volume>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Scheiman]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Gwiazda]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Li]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Non-surgical interventions for convergente insufficiency]]></article-title>
<source><![CDATA[Cochrane Database of Systematic Reviews]]></source>
<year>2011</year>
<numero>3</numero>
<issue>3</issue>
</nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Salvado Arques]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Fransoy Bel]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<source><![CDATA[Tecnología óptica: lentes oftálmicas, diseño y adaptación]]></source>
<year>2001</year>
<publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Ediciones UPC]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Borrás García]]></surname>
<given-names><![CDATA[MR]]></given-names>
</name>
<name>
<surname><![CDATA[Ondategui Parra]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[acheco Cutillas]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Varon]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Sánchez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Gispets]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<source><![CDATA[Visión binocular. Diagnóstico y tratamiento]]></source>
<year>1996</year>
<publisher-loc><![CDATA[Barcelona ]]></publisher-loc>
<publisher-name><![CDATA[Edicions UPC]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kim]]></surname>
<given-names><![CDATA[KM]]></given-names>
</name>
<name>
<surname><![CDATA[Chun]]></surname>
<given-names><![CDATA[BY]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Effectiveness of home-based pencil push-ups (HBPP) for patients with symptomatic convergence insufficiency]]></article-title>
<source><![CDATA[Korean J Ophthalmol.]]></source>
<year>2011</year>
<volume>25</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>185-8</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
