<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1684-1859</journal-id>
<journal-title><![CDATA[Revista Cubana de Informática Médica]]></journal-title>
<abbrev-journal-title><![CDATA[RCIM]]></abbrev-journal-title>
<issn>1684-1859</issn>
<publisher>
<publisher-name><![CDATA[Universidad de Ciencias Médicas de La Habana]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1684-18592020000100020</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Herramienta basada en código abierto para el cálculo de blindaje en las instalaciones de Medicina Nuclear]]></article-title>
<article-title xml:lang="en"><![CDATA[Open Source Based Tool for Shielding Calculation in Nuclear Medicine Installations]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[García-Ramó]]></surname>
<given-names><![CDATA[Karla Batista]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Domínguez Martínez]]></surname>
<given-names><![CDATA[Jorge Luis]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López Díaz]]></surname>
<given-names><![CDATA[Adlín]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Águila Ruiz]]></surname>
<given-names><![CDATA[Ángel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Varela Corona]]></surname>
<given-names><![CDATA[Consuelo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Centro Internacional de Restauración Neurológica Departamento de Medicina Nuclear ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Hospital Hermanos Ameijeiras Departamento de Medicina Nuclear ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Centro Estatal de Medicamentos, Equipos y Dispositivos Médicos  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>06</month>
<year>2020</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>06</month>
<year>2020</year>
</pub-date>
<volume>12</volume>
<numero>1</numero>
<fpage>20</fpage>
<lpage>30</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1684-18592020000100020&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1684-18592020000100020&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1684-18592020000100020&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN Uno de los requerimientos indispensables en el diseño de las instalaciones donde se trabaja con radiación ionizante es la determinación del espesor adecuado de las paredes, pisos, techo y puertas de los locales, que garanticen dosis por debajo de las restricciones establecidas por la autoridad regulatoria. El objetivo del presente trabajo es desarrollar una herramienta interactiva, libre y de código abierto para calcular los blindajes requeridos en una instalación de Medicina Nuclear. En el código, desarrollado en Phyton utilizando el entorno interactivo Jupiter Notebook, se incluyó el análisis tanto para Tomografía por Emisión de Fotón Único como para Tomografía por Emisión de Positrones. La herramienta fue implementada para el cálculo de los blindajes de un departamento de Medicina Nuclear del Centro Internacional de Restauración Neurológica (CIREN). Esta herramienta libre y de código abierto facilita los cálculos de blindaje aumentando la velocidad, lo que contribuye a lograr una optimización de la protección radiológica, pero también puede usarse como herramienta pedagógica.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT One of the indispensable requirements in the design of the facilities where ionizing radiation is used is the determination of the adequate thickness of the walls, floors, ceiling and doors of the premises, which guarantee doses below the restrictions established by the regulatory authority.. The goal of this work is to develop an interactive, free and open source tool to calculate the shields required in a Nuclear Medicine installation. Analysis for both Single Photon Emission Tomography and Positron Emission Tomography was included in the code, developed in Phyton using the interactive Jupiter Notebook environment. The tool was implemented to calculate the shields of a Nuclear Medicine department of the International Center for Neurological Restoration (CIREN). This free and open source tool facilitates shielding calculations by increasing speed, which contributes to the optimization of radiation protection, but can also be used as a pedagogical tool.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[Código libre y abierto]]></kwd>
<kwd lng="es"><![CDATA[cálculo de blindaje]]></kwd>
<kwd lng="es"><![CDATA[protección radiológica]]></kwd>
<kwd lng="en"><![CDATA[free and open source tool]]></kwd>
<kwd lng="en"><![CDATA[shielding calculation]]></kwd>
<kwd lng="en"><![CDATA[radiation protection]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Serencsits]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Quinn]]></surname>
<given-names><![CDATA[BM]]></given-names>
</name>
<name>
<surname><![CDATA[Dauer]]></surname>
<given-names><![CDATA[LT]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[An Introduction to Radiation Protection]]></article-title>
<source><![CDATA[Radiopharmaceutical Chemistry]]></source>
<year>2019</year>
<page-range>515-29</page-range><publisher-name><![CDATA[Springer]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="book">
<collab>IAEA</collab>
<source><![CDATA[Radiation Protection and Safety of Radiation Sources: International Basic Safety Standards]]></source>
<year>2014</year>
<publisher-loc><![CDATA[Vienna ]]></publisher-loc>
<publisher-name><![CDATA[INTERNATIONAL ATOMIC ENERGY AGENCY]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<collab>ICRP</collab>
<article-title xml:lang=""><![CDATA[Publication 105 Radiation protection in medicine]]></article-title>
<source><![CDATA[Ann ICRP]]></source>
<year>2007</year>
<volume>37</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1-63</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="book">
<collab>NCRP</collab>
<source><![CDATA[Structural Shielding Design for Medical X-Ray Imaging Facilities]]></source>
<year>2004</year>
<publisher-loc><![CDATA[Bethesda, Maryland ]]></publisher-loc>
<publisher-name><![CDATA[National Council on Radiation Protection and Measurements]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<collab>ICRP</collab>
<article-title xml:lang=""><![CDATA[The 2007 Recommendations of the International Commission on Radiological Protection. ICRP publication 103]]></article-title>
<source><![CDATA[Ann ICRP]]></source>
<year>2007</year>
<volume>37</volume>
<numero>2-4</numero>
<issue>2-4</issue>
<page-range>1-332</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="book">
<collab>NCRP</collab>
<source><![CDATA[Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities]]></source>
<year>2005</year>
<publisher-loc><![CDATA[Bethesda, Maryland ]]></publisher-loc>
<publisher-name><![CDATA[National Council on Radiation Protection and Measurements]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Madsen]]></surname>
<given-names><![CDATA[MT]]></given-names>
</name>
<name>
<surname><![CDATA[Anderson]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Halama]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
<name>
<surname><![CDATA[Kleck]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Simpkin]]></surname>
<given-names><![CDATA[DJ]]></given-names>
</name>
<name>
<surname><![CDATA[Votaw]]></surname>
<given-names><![CDATA[JR]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[AAPM Task Group 108: PET and PET/CT shielding requirements]]></article-title>
<source><![CDATA[Med Phys]]></source>
<year>2006</year>
<volume>33</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>4-15</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Archer]]></surname>
<given-names><![CDATA[BR]]></given-names>
</name>
<name>
<surname><![CDATA[Fewell]]></surname>
<given-names><![CDATA[TR]]></given-names>
</name>
<name>
<surname><![CDATA[Conway]]></surname>
<given-names><![CDATA[BJ]]></given-names>
</name>
<name>
<surname><![CDATA[Quinn]]></surname>
<given-names><![CDATA[PW]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Attenuation properties of diagnostic x-ray shielding materials]]></article-title>
<source><![CDATA[Med Phys]]></source>
<year>1994</year>
<volume>21</volume>
<numero>9</numero>
<issue>9</issue>
<page-range>1499-507</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="book">
<collab>ICRU</collab>
<source><![CDATA[Quantities and Units in Radiation Protection Dosimetry (Report 51)]]></source>
<year>1993</year>
<publisher-loc><![CDATA[Washington D.C., USA ]]></publisher-loc>
<publisher-name><![CDATA[International Commission on Radiation Units &amp; Measurements]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Eckerman]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Endo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[ICRP Publication 107 Nuclear decay data for dosimetric calculations]]></article-title>
<source><![CDATA[Ann ICRP]]></source>
<year>2008</year>
<volume>38</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>7-96</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Martin]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Sutton]]></surname>
<given-names><![CDATA[DG]]></given-names>
</name>
</person-group>
<source><![CDATA[Practical radiation protection in healthcare]]></source>
<year>2015</year>
<publisher-loc><![CDATA[Oxford University Press ]]></publisher-loc>
<publisher-name><![CDATA[USA]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="book">
<collab>CNSN</collab>
<source><![CDATA[Guía de seguridad para la práctica de la medicina nuclear]]></source>
<year>2011</year>
<publisher-loc><![CDATA[Centro Nacional de Seguridad Nuclear ]]></publisher-loc>
<publisher-name><![CDATA[Cuba]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B13">
<label>13</label><nlm-citation citation-type="book">
<collab>EPA</collab>
<source><![CDATA[Radiation Guideline 7 Radiation shielding design assessment and verification requirements]]></source>
<year>2015</year>
<publisher-loc><![CDATA[Sydney ]]></publisher-loc>
<publisher-name><![CDATA[The NSW Environment Protection Authority]]></publisher-name>
</nlm-citation>
</ref>
</ref-list>
</back>
</article>