<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1815-5928</journal-id>
<journal-title><![CDATA[Ingeniería Electrónica, Automática y Comunicaciones]]></journal-title>
<abbrev-journal-title><![CDATA[EAC]]></abbrev-journal-title>
<issn>1815-5928</issn>
<publisher>
<publisher-name><![CDATA[Universidad Tecnológica de La Habana José Antonio Echeverría, Cujae]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1815-59282024000300016</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Diseño e implementación de un software para equipos médicos modulares]]></article-title>
<article-title xml:lang="en"><![CDATA[Design and Implementation of a software for modular medical devices.]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pérez Villanueva]]></surname>
<given-names><![CDATA[Hernán D.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Medina Rodríguez]]></surname>
<given-names><![CDATA[Zuliet]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Alfonso Cordovi]]></surname>
<given-names><![CDATA[Adiel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Casanova Pacheco]]></surname>
<given-names><![CDATA[José L.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Corrales Lay]]></surname>
<given-names><![CDATA[Luis R.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Prieto Moreno]]></surname>
<given-names><![CDATA[Alberto S.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Tecnológica de la Habana &#8220;José A. Echeverría&#8221; (CUJAE) Departamento de Automática ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,UCI Departamento de Técnicas de Programación de la Facultad 1 ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,COMBIOMED Tecnología Médica Digital  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af4">
<institution><![CDATA[,Empresa EMSI FARMA S.R.L.  ]]></institution>
<addr-line><![CDATA[La Habana ]]></addr-line>
<country>Cuba</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2024</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2024</year>
</pub-date>
<volume>45</volume>
<numero>3</numero>
<fpage>16</fpage>
<lpage>33</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1815-59282024000300016&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1815-59282024000300016&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1815-59282024000300016&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[RESUMEN Este trabajo trata sobre el diseño e implementación de un software para equipos médicos modulares dedicados a la monitorización de pacientes en terapias. Para ello se utiliza como caso de estudio la familia de monitores de pacientes Doctus del fabricante cubano COMBIOMED. Se persigue el objetivo de generar un software lo suficientemente flexible que permita hacer modificaciones en su distribución, cambios en la configuración de los módulos que admite, y modificación de los algoritmos de procesamiento de señales digitales; sin tener que realizar modificaciones al software. Para el proceso de desarrollo se utiliza una metodología Agile modelo-V, y para la implementación se utiliza la tecnología .NET 6 de Microsoft.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[ABSTRACT This work is about the design and implementation of software for modular medical equipment dedicated to patient monitoring in therapies. The Doctus family of patient monitors from the Cuban manufacturer COMBIOMED is used as a case study. The objective is to generate software that is flexible enough to allow modifications in its distribution, changes in the configuration of the modules it supports, and modification of digital signal processing algorithms, without having to make any changes to the software. An Agile V-model methodology is used for the development process, and Microsoft&#8217;s NET 6 technology is used for the implementation.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[dispositivos médicos modulares]]></kwd>
<kwd lng="es"><![CDATA[diseño de software]]></kwd>
<kwd lng="es"><![CDATA[monitoreo de pacientes]]></kwd>
<kwd lng="en"><![CDATA[modular medical devices]]></kwd>
<kwd lng="en"><![CDATA[software design]]></kwd>
<kwd lng="en"><![CDATA[patient monitoring]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Liu]]></surname>
<given-names><![CDATA[Pu]]></given-names>
</name>
<name>
<surname><![CDATA[Fels]]></surname>
<given-names><![CDATA[Sidney]]></given-names>
</name>
<name>
<surname><![CDATA[West Nicholas]]></surname>
<given-names><![CDATA[Görges]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Human Computer Interaction Design for Mobile Devices Based on a Smart Healthcare Architecture]]></article-title>
<source><![CDATA[Advances in Computers and Software Engineering: Reviews]]></source>
<year>2019</year>
<volume>2</volume>
<page-range>99-13</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gómez Ramírez]]></surname>
<given-names><![CDATA[Ana Rocío]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Evolución y Desafíos en la Verificación y Validación de Dispositivos médicos en Desarrollo]]></article-title>
<source><![CDATA[Congreso Internacional de Investigación Academia Journals]]></source>
<year>2024</year>
<volume>16</volume>
<numero>2</numero>
<issue>2</issue>
</nlm-citation>
</ref>
<ref id="B3">
<label>3.</label><nlm-citation citation-type="confpro">
<person-group person-group-type="author">
<name>
<surname><![CDATA[McHugh]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Cawley]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[McCaffcry]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Richardson]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
<name>
<surname><![CDATA[Wang]]></surname>
<given-names><![CDATA[X]]></given-names>
</name>
</person-group>
<source><![CDATA[An agile V-model for medical device software development to overcome the challenges with plan-driven software development lifecycles]]></source>
<year>2013</year>
<conf-name><![CDATA[ 5International Workshop on Software Engineering in Health Care (SEHC)]]></conf-name>
<conf-loc>San Francisco, CA, USA </conf-loc>
<page-range>12-9</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Khan]]></surname>
<given-names><![CDATA[AA]]></given-names>
</name>
<name>
<surname><![CDATA[Akram]]></surname>
<given-names><![CDATA[MU]]></given-names>
</name>
<name>
<surname><![CDATA[Butt]]></surname>
<given-names><![CDATA[WH]]></given-names>
</name>
<name>
<surname><![CDATA[Sirshar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[An Enhanced Agile V-Model: Conformance to regulatory bodies and experiences from model's adoption to medical device development]]></article-title>
<source><![CDATA[Heliyon]]></source>
<year>2024</year>
<volume>10</volume>
<numero>6</numero>
<issue>6</issue>
</nlm-citation>
</ref>
<ref id="B5">
<label>5.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kasoju]]></surname>
<given-names><![CDATA[N.]]></given-names>
</name>
<name>
<surname><![CDATA[Remya]]></surname>
<given-names><![CDATA[N.S.]]></given-names>
</name>
<name>
<surname><![CDATA[Sasi]]></surname>
<given-names><![CDATA[R.]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Digital health: trends, opportunities and challenges in medical devices, pharma and bio-technology]]></article-title>
<source><![CDATA[CSIT]]></source>
<year>2023</year>
<volume>11</volume>
<page-range>11-30</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Gerodimos]]></surname>
<given-names><![CDATA[Apostolos]]></given-names>
</name>
<name>
<surname><![CDATA[Maglaras]]></surname>
<given-names><![CDATA[Leandros]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[IoT: Communication protocols and security threats]]></article-title>
<source><![CDATA[Internet of Things and Cyber-Physical Systems]]></source>
<year>2023</year>
<volume>3</volume>
<page-range>1-13</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jorge]]></surname>
<given-names><![CDATA[Gómez]]></given-names>
</name>
<name>
<surname><![CDATA[Byron]]></surname>
<given-names><![CDATA[Oviedo]]></given-names>
</name>
<name>
<surname><![CDATA[Emilio]]></surname>
<given-names><![CDATA[Zhuma]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Patient Monitoring System Based on Internet of Things]]></article-title>
<source><![CDATA[Procedia Computer Science]]></source>
<year>2016</year>
<volume>83</volume>
<page-range>90-7</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8.</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ali]]></surname>
<given-names><![CDATA[Mian Mujtaba]]></given-names>
</name>
<name>
<surname><![CDATA[Haxha]]></surname>
<given-names><![CDATA[Shyqyri]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Design of Internet of Things (IoT) and Android Based Low Cost Health Monitoring Embedded System Wearable Sensor for Measuring SpO2, Heart Rate and Body Temperature Simultaneously]]></article-title>
<source><![CDATA[Wireless Personal Communications]]></source>
<year>2019</year>
</nlm-citation>
</ref>
<ref id="B9">
<label>9.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Margaret]]></surname>
<given-names><![CDATA[Harvey]]></given-names>
</name>
<name>
<surname><![CDATA[Amber]]></surname>
<given-names><![CDATA[Seiler]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Challenges in managing a remote monitoring device clinic]]></article-title>
<source><![CDATA[ALLIED HEALTH PROFESSIONALS]]></source>
<year>2022</year>
<volume>3</volume>
<page-range>4-7</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10.</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bora]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Kanakaraja]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Chiranjeevi]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Smart real time health monitoring system using Arduino and Raspberry Pi]]></article-title>
<source><![CDATA[Materials Today: Proceedings]]></source>
<year>2021</year>
</nlm-citation>
</ref>
<ref id="B11">
<label>11.</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramy]]></surname>
<given-names><![CDATA[Ghanim]]></given-names>
</name>
<name>
<surname><![CDATA[Anika]]></surname>
<given-names><![CDATA[Kaushik]]></given-names>
</name>
<name>
<surname><![CDATA[Jihoon]]></surname>
<given-names><![CDATA[Park]]></given-names>
</name>
<name>
<surname><![CDATA[Alex]]></surname>
<given-names><![CDATA[Abramson]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Communication protocols integrating wearables, ingestibles, and implantables for closed-loop therapies]]></article-title>
<source><![CDATA[Device]]></source>
<year>2023</year>
</nlm-citation>
</ref>
<ref id="B12">
<label>12.</label><nlm-citation citation-type="">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Muhammad]]></surname>
<given-names><![CDATA[Farhan Safdar]]></given-names>
</name>
<name>
<surname><![CDATA[Robert]]></surname>
<given-names><![CDATA[Marek Nowak]]></given-names>
</name>
<name>
<surname><![CDATA[Piotr]]></surname>
<given-names><![CDATA[Pa&#322;ka]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Pre-Processing techniques and artificial intelligence algorithms for electrocardiogram (ECG) signals analysis: A comprehensive review]]></article-title>
<source><![CDATA[Computers in Biology and Medicine]]></source>
<year>2024</year>
</nlm-citation>
</ref>
<ref id="B13">
<label>13.</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jan]]></surname>
<given-names><![CDATA[Maarten Schraagen]]></given-names>
</name>
<name>
<surname><![CDATA[Fenne]]></surname>
<given-names><![CDATA[Verhoeven]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Methods for studying medical device technology and practitioner cognition: The case of user-interface issues with infusion pumps]]></article-title>
<source><![CDATA[Journal of Biomedical Informatics]]></source>
<year>2013</year>
<volume>46</volume>
<page-range>181-95</page-range></nlm-citation>
</ref>
<ref id="B14">
<label>14.</label><nlm-citation citation-type="">
<collab>Mindray</collab>
<source><![CDATA[Advance patient monitoring]]></source>
<year>2024</year>
</nlm-citation>
</ref>
<ref id="B15">
<label>15.</label><nlm-citation citation-type="">
<collab>Meditech</collab>
<source><![CDATA[Multiparameter monitors]]></source>
<year>2024</year>
</nlm-citation>
</ref>
</ref-list>