<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>1815-5944</journal-id>
<journal-title><![CDATA[Ingeniería Mecánica]]></journal-title>
<abbrev-journal-title><![CDATA[Ingeniería Mecánica]]></abbrev-journal-title>
<issn>1815-5944</issn>
<publisher>
<publisher-name><![CDATA[Facultad de Ingeniería Mecánica. Instituto Superior Politécnico "José Antonio Echeverría"]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S1815-59442018000300124</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Diseño y fabricación de un equipo para medir adherencia por rayado]]></article-title>
<article-title xml:lang="en"><![CDATA[Design and manufacturing of a device to measure adherence by scratch]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fumero-Pérez]]></surname>
<given-names><![CDATA[Abel]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Figueroa-Hernández]]></surname>
<given-names><![CDATA[Carlos]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Fernández-Rodríguez]]></surname>
<given-names><![CDATA[Alfredo J.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Mir-Labrada]]></surname>
<given-names><![CDATA[Víctor M.]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Goyos-Pérez]]></surname>
<given-names><![CDATA[Leonardo]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Pantaleón-Matamoros]]></surname>
<given-names><![CDATA[Efraín]]></given-names>
</name>
<xref ref-type="aff" rid="Aff"/>
</contrib>
</contrib-group>
<aff id="Af1">
<institution><![CDATA[,Universidad Tecnológica de la Habana José Antonio Echeverría Facultad de Ingeniería Mecánica ]]></institution>
<addr-line><![CDATA[ La Habana]]></addr-line>
<country>Cuba</country>
</aff>
<aff id="Af2">
<institution><![CDATA[,Universidad de Fuerzas Armadas  ]]></institution>
<addr-line><![CDATA[ Sangolquí]]></addr-line>
<country>Ecuador</country>
</aff>
<aff id="Af3">
<institution><![CDATA[,Universidade Federal do Rio Grande do Norte Escola de Ciências e Tecnologia ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
<country>Brazil</country>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>12</month>
<year>2018</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>12</month>
<year>2018</year>
</pub-date>
<volume>21</volume>
<numero>3</numero>
<fpage>124</fpage>
<lpage>129</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S1815-59442018000300124&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S1815-59442018000300124&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S1815-59442018000300124&amp;lng=en&amp;nrm=iso"></self-uri><abstract abstract-type="short" xml:lang="es"><p><![CDATA[Resumen En el presente trabajo se realizó el diseño y fabricación de un equipo para medir adherencia por rayado en recubrimientos depositados sobre sustratos. Para la fabricación del equipo se diseñaron y construyeron las diferentes partes de este utilizando como método, la modelación auxiliada con el software Inventor profesional 2016 y los procesos tecnológicos de maquinado y corte por láser. Para comprobar la repetitividad de los ensayos a una velocidad lineal de 10 mm/min en correspondencia con la norma ASTM C-1624-5 se utilizó un identificador de esfera. Los rayados realizados mostraron que el equipo posee un funcionamiento satisfactorio.]]></p></abstract>
<abstract abstract-type="short" xml:lang="en"><p><![CDATA[Abstract In this paper was realized the design and manufactured of an equipment to measured adherence by scratch for deposited coating on substrate. For the manufacture of the equipment was designed and built the different parts using as method the assisted modelation in the software professional Inventor and technology process of machined and curt by laser. To determine the repetitive of the test to one line velocity of 10 mm/min in accordance with the norm ASTM C-1642-5 was utilized a sphere indicator. The scratches executed showed that the equipment has a satisfactory performance.]]></p></abstract>
<kwd-group>
<kwd lng="es"><![CDATA[rayado]]></kwd>
<kwd lng="es"><![CDATA[adherencia]]></kwd>
<kwd lng="es"><![CDATA[recubrimiento]]></kwd>
<kwd lng="es"><![CDATA[sustrato]]></kwd>
<kwd lng="en"><![CDATA[scratch]]></kwd>
<kwd lng="en"><![CDATA[adherence]]></kwd>
<kwd lng="en"><![CDATA[coating]]></kwd>
<kwd lng="en"><![CDATA[substrate]]></kwd>
</kwd-group>
</article-meta>
</front><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ghadami]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Ghadami]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Effect of bond coat and post-heat treatment on the adhesion of air plasma sprayed WC-Co coatings]]></article-title>
<source><![CDATA[Surface and Coatings Technology]]></source>
<year>2015</year>
<volume>261</volume>
<page-range>289-94</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Zhou]]></surname>
<given-names><![CDATA[Lu]]></given-names>
</name>
<name>
<surname><![CDATA[Zhang]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Super-hydrophobic film fabricated on aluminium surface as a barrier to atmospheric corrosion in a marine environment]]></article-title>
<source><![CDATA[Corrosion Science]]></source>
<year>2015</year>
<volume>91</volume>
<page-range>287-96</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Jieyin]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
<name>
<surname><![CDATA[Chaojie]]></surname>
<given-names><![CDATA[C]]></given-names>
</name>
<name>
<surname><![CDATA[kun Liao]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Bond strengths of porcelain to cobalt-chromium alloys made by casting, milling, and selective laser melting]]></article-title>
<source><![CDATA[The Journal of Prosthetic Denttistry]]></source>
<year>2017</year>
<volume>118</volume>
<numero>1</numero>
<issue>1</issue>
<page-range>69-75</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chuan]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Escudeiro]]></surname>
<given-names><![CDATA[WA]]></given-names>
</name>
<name>
<surname><![CDATA[Polcar]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Indentation and scratch testing of DLC-Zr coatings on ultrafine-grained titanium processed by high-pressure torsion]]></article-title>
<source><![CDATA[Wear]]></source>
<year>2013</year>
<volume>306</volume>
<numero>1-2</numero>
<issue>1-2</issue>
<page-range>304-10</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Deepak]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Muthukumar]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[Vasanthkumar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Comparative evaluation of effect of laser on shear bond strength of ceramic bonded with two base metal alloys An in-vitro study]]></article-title>
<source><![CDATA[Indian J Dent Res]]></source>
<year>2013</year>
<volume>24</volume>
<numero>5</numero>
<issue>5</issue>
<page-range>610-5</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Kromer]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Costil]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Cormier]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Laser surface patterning to enhance adhesion of plasma sprayed coatings]]></article-title>
<source><![CDATA[Surface and Coatings Technology]]></source>
<year>2015</year>
<volume>278</volume>
<page-range>171-82</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Yonghong]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Fei]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
<name>
<surname><![CDATA[Jinyu]]></surname>
<given-names><![CDATA[Z]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[The effect of adhesive strength of hydroxyapatite coating on the stability of hydroxyapatite-coated prostheses in vivo at the early stage of implantation]]></article-title>
<source><![CDATA[Arch Med Sci]]></source>
<year>2012</year>
<volume>8</volume>
<numero>2</numero>
<issue>2</issue>
<page-range>199-208</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Moya Rodríguez]]></surname>
<given-names><![CDATA[JL]]></given-names>
</name>
<name>
<surname><![CDATA[Velázquez Pérez]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Cálculo de engranajes plásticos]]></article-title>
<source><![CDATA[Ingeniería Mecánica]]></source>
<year>2007</year>
<volume>10</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>25-32</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="book">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Norton]]></surname>
<given-names><![CDATA[RL]]></given-names>
</name>
</person-group>
<source><![CDATA[Design of Machinery. An Introduction to the Synthesis and Analysis of Mechanisms and Machines]]></source>
<year>1999</year>
<edition>Second ed</edition>
<publisher-loc><![CDATA[New York, USA ]]></publisher-loc>
<publisher-name><![CDATA[McGraw-Hill]]></publisher-name>
</nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Fernández Prada]]></surname>
<given-names><![CDATA[JM]]></given-names>
</name>
<name>
<surname><![CDATA[García Cuenca]]></surname>
<given-names><![CDATA[MV]]></given-names>
</name>
<name>
<surname><![CDATA[Cleries]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Influence of the interface layer on the adhesion of pulsed laser deposited hydroxyapatite coatings on titanium alloy]]></article-title>
<source><![CDATA[Applied Surface Science]]></source>
<year>2002</year>
<volume>195</volume>
<page-range>31-7</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[de Sousa]]></surname>
<given-names><![CDATA[GB]]></given-names>
</name>
<name>
<surname><![CDATA[de Lima GG]]></surname>
<given-names><![CDATA[Kuromoto]]></given-names>
</name>
<name>
<surname><![CDATA[Neide]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Tribo-mechanical characterization of rough, porous and bioactive Ti anodic layers]]></article-title>
<source><![CDATA[Journal of the Mechanical Behavior of Biomedical Materials]]></source>
<year>2011</year>
<volume>4</volume>
<page-range>796-806</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Szesz]]></surname>
<given-names><![CDATA[EM]]></given-names>
</name>
<name>
<surname><![CDATA[de Souza Gelson]]></surname>
<given-names><![CDATA[B]]></given-names>
</name>
<name>
<surname><![CDATA[de Lima Gabriel]]></surname>
<given-names><![CDATA[G]]></given-names>
</name>
</person-group>
<article-title xml:lang=""><![CDATA[Improved tribo-mechanical behavior of CaP-containing TiO2 layers produced on titanium by shot blasting and micro-arc oxidation]]></article-title>
<source><![CDATA[J Mater Sci: Mater Med]]></source>
<year>2014</year>
<volume>25</volume>
<page-range>2265-75</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>
