<?xml version="1.0" encoding="ISO-8859-1"?><article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id>2078-7170</journal-id>
<journal-title><![CDATA[CorSalud]]></journal-title>
<abbrev-journal-title><![CDATA[CorSalud]]></abbrev-journal-title>
<issn>2078-7170</issn>
<publisher>
<publisher-name><![CDATA[Cardiocentro Ernesto Che Guevara]]></publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id>S2078-71702018000300010</article-id>
<title-group>
<article-title xml:lang="es"><![CDATA[Síndrome de Reel en un paciente portador de un cardiodesfibrilador automático implantable]]></article-title>
<article-title xml:lang="en"><![CDATA[Reel syndrome in a patient with an implantable cardioverter-defibrillator]]></article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Cruz Cardentey]]></surname>
<given-names><![CDATA[Marleny]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Castro Hevia]]></surname>
<given-names><![CDATA[Jesús A]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Castañeda Chirino]]></surname>
<given-names><![CDATA[Osmín]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[Falcón Rodríguez]]></surname>
<given-names><![CDATA[Roylán]]></given-names>
</name>
</contrib>
<contrib contrib-type="author">
<name>
<surname><![CDATA[López Martínez]]></surname>
<given-names><![CDATA[Frank]]></given-names>
</name>
</contrib>
</contrib-group>
<aff id="A">
<institution><![CDATA[,  ]]></institution>
<addr-line><![CDATA[ ]]></addr-line>
</aff>
<pub-date pub-type="pub">
<day>00</day>
<month>09</month>
<year>2018</year>
</pub-date>
<pub-date pub-type="epub">
<day>00</day>
<month>09</month>
<year>2018</year>
</pub-date>
<volume>10</volume>
<numero>3</numero>
<fpage>252</fpage>
<lpage>255</lpage>
<copyright-statement/>
<copyright-year/>
<self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_arttext&amp;pid=S2078-71702018000300010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_abstract&amp;pid=S2078-71702018000300010&amp;lng=en&amp;nrm=iso"></self-uri><self-uri xlink:href="http://scielo.sld.cu/scielo.php?script=sci_pdf&amp;pid=S2078-71702018000300010&amp;lng=en&amp;nrm=iso"></self-uri></article-meta>
</front><body><![CDATA[ <P align="right"><font size="2"><b><font face="Verdana, Arial, Helvetica, sans-serif"><font face="Verdana, Arial, Helvetica, sans-serif">CASO CL&Iacute;NICO</font></B></font>     <p>&nbsp;</p>     <P><font size="4"><b><font face="Verdana, Arial, Helvetica, sans-serif">S&iacute;ndrome de Reel en un paciente portador de un cardiodesfibrilador    autom&aacute;tico implantable</font></b></font><font size="2"><b><font face="Verdana, Arial, Helvetica, sans-serif"></font></b> </font>     <p>&nbsp;</p>     <P><font size="3"><b><font face="Verdana, Arial, Helvetica, sans-serif">Reel syndrome in a patient with an implantable    cardioverter-defibrillator</font></b></font><font size="2"><b><font face="Verdana, Arial, Helvetica, sans-serif"></font></b> </font>     <p>&nbsp;</p>     <p>&nbsp;</p>     <P><font size="2"><b><font face="Verdana, Arial, Helvetica, sans-serif">Marleny Cruz Cardentey<SUP>1</SUP>, Jes&uacute;s A. Castro    Hevia<SUP>2</SUP>, Osm&iacute;n Casta&ntilde;eda    Chirino<SUP>2</SUP>, Royl&aacute;n Falc&oacute;n    Rodr&iacute;guez<SUP>2</SUP>, Frank L&oacute;pez  Mart&iacute;nez<SUP>2</SUP></font></b></font>      <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">1.     Departamento de Arritmia y Marcapasos, Hospital Cl&iacute;nico Quir&uacute;rgico Hermanos Ameijeiras. La  Habana, Cuba. Correo electr&oacute;nico: <U><FONT  COLOR="#0000ff"><a href="mailto: marleny.cruz@infomed.sld.cu">marleny.cruz@infomed.sld.cu</a></FONT></U>    <br> </font><font size="2" face="Verdana, Arial, Helvetica, sans-serif">2.     Servicio de Electrofisiolog&iacute;a, Arritmia y Marcapasos. Instituto de Cardiolog&iacute;a y Cirug&iacute;a Cardiovascular.  La Habana, Cuba.</font> <hr>     ]]></body>
<body><![CDATA[<P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>RESUMEN</B> </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El s&iacute;ndrome <I>Twiddler</I> y su variante el s&iacute;ndrome de <I>Reel</I>, son complicaciones poco frecuentes en los  pacientes portadores de un cardiodesfibrilador autom&aacute;tico implantable; pero pueden provocar disfunci&oacute;n severa  del dispositivo. La identificaci&oacute;n de los factores predisponentes y la intervenci&oacute;n sobre ellos, as&iacute; como  el seguimiento peri&oacute;dico del funcionamiento mediante telemetr&iacute;a y radiograf&iacute;a de t&oacute;rax, son &uacute;tiles en la  prevenci&oacute;n de estos s&iacute;ndromes. Se describe el caso de un paciente con s&iacute;ndrome de <I>Reel</I> al tercer mes del implante de un cardiodesfibrilador, como consecuencia de una sepsis del bolsillo del generador.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B><I>Palabras clave:</I></B> s&iacute;ndrome de <I>Reel</I>, desfibrilador autom&aacute;tico implantable, eletrodos, complicaciones.</font> <hr>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>ABSTRACT</B> </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">The Twiddler syndrome and its variant, the Reel syndrome, are uncommon complications in patients with  an implantable cardioverter-defibrillator, but they can cause severe device dysfunction. The identification of  the predisposing factors and the intervention on them, as well as the periodic monitoring of the operation by  means of telemetry and chest radiography, are useful in the prevention of these syndromes. Here is described the  case of a patient with Reel syndrome at the third month after the implantation of a cardioverter-defibrillator, as a  result of a sepsis in the generator pocket.</font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B><I>Keywords:</I></B> reel syndrome, implantable cardioverter-defibrillator, electrodes, complications.</font> <hr>     <p><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>INTRODUCCI&Oacute;N</B> </font></p>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">El s&iacute;ndrome de <I>Twiddler</I> fue descrito por primera vez en un paciente con marcapasos unicameral en 1968  por Bayliss <I>et al</I><SUP>1</SUP>. Consiste en la rotaci&oacute;n del generador en su eje axial con torsi&oacute;n de los electrodos, que  puede llegar a su fractura o desplazamiento y, por consiguiente, provocar disfunci&oacute;n del dispositivo. Veltri <I>et al</I><SUP>2</SUP> informaron por primera vez la presencia de este s&iacute;ndrome en un paciente con cardiodesfibrilador  autom&aacute;tico implantable (CDAI) en el a&ntilde;o 1984.     <BR> El s&iacute;ndrome de <I>Reel</I> es una variante del s&iacute;ndrome de <I>Twiddler</I>, en el cual la rotaci&oacute;n del generador ocurre en  su eje transversal, con enrollamiento (<I>reel</I>) de los electrodos alrededor del dispositivo. Carnero-Varo  <I>et al</I><SUP>3</SUP>, en el a&ntilde;o1999, realizaron la primera descripci&oacute;n en un paciente con marcapasos unicameral. A continuaci&oacute;n,  se describe el caso de un paciente con s&iacute;ndrome de <I>Reel</I> al tercer mes de la implantaci&oacute;n de un CDAI. </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>CASO CL&Iacute;NICO</B> </font>     ]]></body>
<body><![CDATA[<P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Paciente masculino, de 38 a&ntilde;os de edad, normopeso, sin antecedentes patol&oacute;gicos personales de inter&eacute;s  y con el diagn&oacute;stico de fibrilaci&oacute;n ventricular primaria. Se le implant&oacute; un CDAI VDD (Iforia 5 VR-T-Dx) por v&iacute;a  de acceso cef&aacute;lica izquierda. El electrodo de fijaci&oacute;n activa (Protego DF-1-Pro MRI Dx 65/15) se ubic&oacute; en el  &aacute;pex del ventr&iacute;culo derecho y se fij&oacute; a la fascia muscular pectoral con los correspondientes anillos de fijaci&oacute;n.  Las medidas al implante fueron las siguientes: umbral 0,7 V; amplitud de la onda R 6,7 mV; amplitud de la onda  P 2,2 mV; e impedancia 552 &Ugrave;. El generador se  ubic&oacute; en un bolsillo subcut&aacute;neo y no se fij&oacute; a la fascia  muscular. Se program&oacute; una frecuencia b&aacute;sica de estimulaci&oacute;n de 40 latidos por minutos (lpm) y una ventana de  fibrilaci&oacute;n ventricular de 200 lpm.    <BR> Al tercer mes del implante el paciente acudi&oacute; a la primera consulta de seguimiento y refiri&oacute; molestias ligeras  en la zona del bolsillo, pero sin signos de inflamaci&oacute;n aguda. El electrocardiograma (<a href="#f0110318">Figura 1</a>) mostr&oacute; ritmo  sinusal con una frecuencia card&iacute;aca de 80 lpm, fallo de captura del canal ventricular y de detecci&oacute;n de ambos  canales. Se realiz&oacute; telemetr&iacute;a del dispositivo, la cual demostr&oacute; una impedancia del electrodo ventricular de 560  &Ugrave; y del electrodo de desfibrilaci&oacute;n de 54  &Ugrave;, ausencia de detecci&oacute;n de las ondas R y P, y fallo de captura ventricular.  La radiograf&iacute;a de t&oacute;rax anteroposterior (<a href="#f0210318">Figura 2</a>) mostr&oacute; una retracci&oacute;n del electrodo, con ubicaci&oacute;n del  extremo distal a nivel de la vena innominada, enrollado alrededor del generador, compatible con un s&iacute;ndrome de <I>Reel</I>. No se recogi&oacute; en el paciente el antecedente de una manipulaci&oacute;n excesiva del generador, ni de la realizaci&oacute;n  de vicios posturales repetitivos. </font>     <P align="center"><a name="f0110318"></a><img src="/img/revistas/cs/v10n3/f0110318.jpg" width="461" height="424">     
<p>&nbsp;</p>     <p align="center"><a name="f0210318"></a><img src="/img/revistas/cs/v10n3/f0210318.jpg" width="354" height="413"></p>     
<P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Al realizar la intervenci&oacute;n quir&uacute;rgica para recolocar el electrodo se observ&oacute; una sepsis del bolsillo  con dehiscencia de los puntos de fijaci&oacute;n del electrodo. Se extrajo totalmente el sistema infectado y no se  constat&oacute; fractura del electrodo. El paciente se neg&oacute; al reimplante de un nuevo sistema del lado contralateral, por lo  que se inici&oacute; tratamiento con sulfato de quinidina 200 mg cada 8 horas. </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif"><B>COMENTARIO</B> </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los s&iacute;ndromes de <I>Twiddler</I> y      <I>Reel</I> son poco frecuentes en los pacientes portadores de sistemas  de estimulaci&oacute;n card&iacute;aca. Se producen por mecanismos diferentes, pero en com&uacute;n son causas de disfunci&oacute;n  de los dispositivos. En la mayor&iacute;a de los informes de s&iacute;ndrome de <I>Reel</I> los electrodos est&aacute;n desplazados, pero  sin da&ntilde;os, a diferencia del s&iacute;ndrome de <I>Twiddler</I>, donde el mecanismo de rotaci&oacute;n produce fracturas de los  cables<SUP>4</SUP>. En este paciente se observ&oacute; un desplazamiento del electrodo hasta la vena innominada, con  enrollamiento alrededor del generador, pero sin fractura. Los valores normales de las impedancias de estimulaci&oacute;n y  de desfibrilaci&oacute;n demostraron la integridad de la sonda.    <BR> Las formas de presentaci&oacute;n de estos s&iacute;ndromes son variables y su prevalencia es de aproximadamente  0,07%<SUP>5</SUP>. El desplazamiento o fractura de los electrodos puede producir fallo de detecci&oacute;n, aumento de la impedancia  o del umbral de estimulaci&oacute;n, con fallo de captura y estimulaci&oacute;n fr&eacute;nica, braquial o pectoral. En los portadores  de CDAI se pueden presentar fallos en la detecci&oacute;n por defecto o exceso, as&iacute; como aumento del umbral  de desfibrilaci&oacute;n con inefectividad de la  terapia<SUP>6,7</SUP>. El fallo de detecci&oacute;n y de captura tuvo un curso asintom&aacute;tico  en este paciente no dependiente de la estimulaci&oacute;n de marcapasos. Tampoco se registraron disfunciones de  la terapia del CDAI.     <BR> La radiograf&iacute;a de t&oacute;rax confirma el diagn&oacute;stico al demostrar la rotaci&oacute;n del generador dentro del bolsillo,  el desplazamiento de los electrodos endocavitarios y el enrollamiento de &eacute;stos alrededor del  generador<SUP>8</SUP>.    ]]></body>
<body><![CDATA[<BR> En algunos casos se ha podido demostrar una manipulaci&oacute;n excesiva voluntaria o involuntaria del generador  por parte del paciente, pero en la inmensa mayor&iacute;a se desconoce la causa. Se han descrito  factores predisponentes para el desarrollo de estos s&iacute;ndromes, como: el sexo femenino, la edad avanzada, la  obesidad, las enfermedades neuro-psiqui&aacute;tricas, los vicios posturales repetitivos, los bolsillos subcut&aacute;neos muy  amplios, el peso y tama&ntilde;o del generador, la ubicaci&oacute;n abdominal y el recambio del dispositivo por otro de  menor tama&ntilde;o<SUP>9,10</SUP>.    <BR> Se proponen algunas medidas en el momento del implante para prevenir estos s&iacute;ndromes, tales como: fijar a  la fascia muscular el generador y los electrodos con sus correspondientes anillos de fijaci&oacute;n, ubicar el  generador subpectoral, emplear una bolsa de dacr&oacute;n y limitar el tama&ntilde;o del bolsillo, aunque esta &uacute;ltima medida  puede favorecer la necrosis as&eacute;ptica.    <BR> La infecci&oacute;n en el primoimplante del CDAI es infrecuente y oscila entre 0,4-5,0%, seg&uacute;n las distintas  series<SUP>11</SUP>. Consideramos que la p&eacute;rdida de los puntos de fijaci&oacute;n del electrodo a consecuencia de la sepsis, fue el  factor predisponente para el desarrollo del s&iacute;ndrome de <I>Reel</I> en este caso<SUP>9,12</SUP>.    <BR> La identificaci&oacute;n temprana de los pacientes con factores predisponentes y el seguimiento peri&oacute;dico  del funcionamiento y la ubicaci&oacute;n de los electrodos, mediante telemetr&iacute;a y radiograf&iacute;a de t&oacute;rax, garantizan  un diagn&oacute;stico precoz de estos s&iacute;ndromes y se evitan complicaciones mayores por disfunci&oacute;n de los dispositivos.</font>     <p>&nbsp;</p>     <P><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>CONFLICTOS DE INTERESES</B></font><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> </font>     <P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Los autores declaran que no existen conflictos de intereses. </font>     <p>&nbsp;</p>     <P><font size="3" face="Verdana, Arial, Helvetica, sans-serif"><B>BIBLIOGRAF&Iacute;A</B></font><font size="2" face="Verdana, Arial, Helvetica, sans-serif"> </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">1.     Bayliss CE, Beanlands DS, Baird RJ. The pacemaker-twiddler's syndrome: A new complication  of implantable transvenous pacemakers. Can Med Assoc J. 1968;99(8):371-3.     </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">2.     Veltri EP, Mower MM, Reid PR. Twiddler's syndrome: A new twist. Pacing Clin Electrophysiol. 1984;7(6  Pt 1):1004-9.     </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">3.     Carnero-Varo A, P&eacute;rez-Paredes M, Ruiz-Ros JA, Gim&eacute;nez-Cervantes D, Mart&iacute;nez-Corbal&aacute;n FR,  Cubero-L&oacute;pez T, <I>et al</I>. &quot;Reel syndrome&quot;: A new form of Twiddler's syndrome? Circulation. 1999;100(8):e45-6.     </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">4.     Munawar M, Munawar DL, Basalamah F, Pambudi J. Reel syndrome: A variant form of Twiddler's  syndrome. J Arrhythmia. 2011;27(4):338-42.     </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">5.     Konishi H, Tokano T, Nakazato Y, Komatsu S, Suwa S, Komatsu K,      <I>et al</I>. Twiddler's syndrome detected by patient's complaint of implantable cardioverter-defibrillator rotation in the subcutaneous pocket. J  Arrhythm. 2012;28(4):239-41.     </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">6.     Patel MB, Pandya K, Shah AJ, Lojewski E, Castellani MD, Thakur R. Reel syndrome _ not a  twiddler variant. J Interv Card Electrophysiol. 2008;23(3):243-6.     </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">7.     Chemello D, Subramanian A, Cameron D. Twiddler syndrome with 180&#176; rotation of an  implantable cardioverter defibrillator generator resulting in malfunction of one of the shocking coils.  Europace. 2009;11(10):1259.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">8. Ram&iacute;rez P, Barrero R, Gonz&aacute;lez R,  Frangini P, Vergara I. S&iacute;ndrome de Twiddler: una causa infrecuente de  disfunci&oacute;n de marcapaso definitivo. Rev Med Chile. 2011;139(7):917-9.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">9. Larrouse E, Rodr&iacute;guez E, Moya A,  Rodr&iacute;guez O, Soler Soler J. S&iacute;ndrome de Twiddler en un paciente portador de  desfibrilador autom&aacute;tico implantable: &iquest;una complicaci&oacute;n evitable? Rev Esp  Cardiol. 2001;54(12):1456-8.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">10. Ejima K, Shoda M, Manaka T, Hagiwara  N. Reel syndrome. J Cardiovasc Electrophysiol. 2009;20(7):822.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">11. van Rees JB, de Bie MK, Thijssen J,  Borleffs CJ, Schalij MJ, van Erven L. Implantation-related complications of  implantable cardioverter-defibrillators and cardiac resynchronization therapy  devices: a systematic review of randomized clinical trials. J Am Coll Cardiol.  2011;58(10):995-1000.    </font>     <!-- ref --><P><font size="2" face="Verdana, Arial, Helvetica, sans-serif">12. Echeverri D, Bar&oacute;n AM, Garc&iacute;a JC,  Ram&iacute;rez JD. S&iacute;ndrome de reel: una variante del s&iacute;ndrome de Twiddler. Rev Colomb  Cardiol. 2015;22(3):153-5.    </font>     <p>&nbsp;</p>     <p>&nbsp;</p>     <p><font size="2" face="Verdana, Arial, Helvetica, sans-serif">Recibido: 20 de abril de 2018    <br>   Aceptado: 7 de junio de 2018</font></p>     <p>&nbsp;</p>     <p>&nbsp;</p> <font size="2" face="Verdana, Arial, Helvetica, sans-serif"><em>Marleny Cruz Cardentey</em>.  Departamento de Arritmia y Marcapasos, Hospital Cl&iacute;nico Quir&uacute;rgico Hermanos  Ameijeiras. La Habana,  Cuba. Correo electr&oacute;nico: <a href="mailto:marleny.cruz@infomed.sld.cu">marleny.cruz@infomed.sld.cu</a></font>     <P>     ]]></body>
<body><![CDATA[ ]]></body><back>
<ref-list>
<ref id="B1">
<label>1</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Bayliss]]></surname>
<given-names><![CDATA[CE]]></given-names>
</name>
<name>
<surname><![CDATA[Beanlands]]></surname>
<given-names><![CDATA[DS]]></given-names>
</name>
<name>
<surname><![CDATA[Baird]]></surname>
<given-names><![CDATA[RJ]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[The pacemaker-twiddler's syndrome: A new complication of implantable transvenous pacemakers]]></article-title>
<source><![CDATA[Can Med Assoc J]]></source>
<year>1968</year>
<volume>99</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>371-3</page-range></nlm-citation>
</ref>
<ref id="B2">
<label>2</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Veltri]]></surname>
<given-names><![CDATA[EP]]></given-names>
</name>
<name>
<surname><![CDATA[Mower]]></surname>
<given-names><![CDATA[MM]]></given-names>
</name>
<name>
<surname><![CDATA[Reid]]></surname>
<given-names><![CDATA[PR]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Twiddler's syndrome: A new twist]]></article-title>
<source><![CDATA[Pacing Clin Electrophysiol]]></source>
<year>1984</year>
<volume>7</volume>
<numero>6</numero>
<issue>6</issue>
<page-range>1004-9</page-range></nlm-citation>
</ref>
<ref id="B3">
<label>3</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Carnero-Varo]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Pérez-Paredes]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Ruiz-Ros]]></surname>
<given-names><![CDATA[JA]]></given-names>
</name>
<name>
<surname><![CDATA[Giménez-Cervantes]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Martínez-Corbalán]]></surname>
<given-names><![CDATA[FR]]></given-names>
</name>
<name>
<surname><![CDATA[Cubero-López]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA["Reel syndrome": A new form of Twiddler's syndrome?]]></article-title>
<source><![CDATA[Circulation]]></source>
<year>1999</year>
<volume>100</volume>
<numero>8</numero>
<issue>8</issue>
<page-range>e45-6</page-range></nlm-citation>
</ref>
<ref id="B4">
<label>4</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Munawar]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Munawar]]></surname>
<given-names><![CDATA[DL]]></given-names>
</name>
<name>
<surname><![CDATA[Basalamah]]></surname>
<given-names><![CDATA[F]]></given-names>
</name>
<name>
<surname><![CDATA[Pambudi]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reel syndrome: A variant form of Twiddler's syndrome]]></article-title>
<source><![CDATA[J Arrhythmia]]></source>
<year>2011</year>
<volume>27</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>338-42</page-range></nlm-citation>
</ref>
<ref id="B5">
<label>5</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Konishi]]></surname>
<given-names><![CDATA[H]]></given-names>
</name>
<name>
<surname><![CDATA[Tokano]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Nakazato]]></surname>
<given-names><![CDATA[Y]]></given-names>
</name>
<name>
<surname><![CDATA[Komatsu]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Suwa]]></surname>
<given-names><![CDATA[S]]></given-names>
</name>
<name>
<surname><![CDATA[Komatsu]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Twiddler's syndrome detected by patient's complaint of implantable cardioverter-defibrillator rotation in the subcutaneous pocket]]></article-title>
<source><![CDATA[J Arrhythm]]></source>
<year>2012</year>
<volume>28</volume>
<numero>4</numero>
<issue>4</issue>
<page-range>239-41</page-range></nlm-citation>
</ref>
<ref id="B6">
<label>6</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Patel]]></surname>
<given-names><![CDATA[MB]]></given-names>
</name>
<name>
<surname><![CDATA[Pandya]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Shah]]></surname>
<given-names><![CDATA[AJ]]></given-names>
</name>
<name>
<surname><![CDATA[Lojewski]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Castellani]]></surname>
<given-names><![CDATA[MD]]></given-names>
</name>
<name>
<surname><![CDATA[Thakur]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reel syndrome _ not a twiddler variant]]></article-title>
<source><![CDATA[J Interv Card Electrophysiol]]></source>
<year>2008</year>
<volume>23</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>243-6</page-range></nlm-citation>
</ref>
<ref id="B7">
<label>7</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Chemello]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Subramanian]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Cameron]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Twiddler syndrome with 180° rotation of an implantable cardioverter defibrillator generator resulting in malfunction of one of the shocking coils]]></article-title>
<source><![CDATA[Europace]]></source>
<year>2009</year>
<volume>11</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>1259</page-range></nlm-citation>
</ref>
<ref id="B8">
<label>8</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Barrero]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[González]]></surname>
<given-names><![CDATA[R]]></given-names>
</name>
<name>
<surname><![CDATA[Frangini]]></surname>
<given-names><![CDATA[P]]></given-names>
</name>
<name>
<surname><![CDATA[Vergara]]></surname>
<given-names><![CDATA[I]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Síndrome de Twiddler: una causa infrecuente de disfunción de marcapaso definitivo]]></article-title>
<source><![CDATA[Rev Med Chile]]></source>
<year>2011</year>
<volume>139</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>917-9</page-range></nlm-citation>
</ref>
<ref id="B9">
<label>9</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Larrouse]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[E]]></given-names>
</name>
<name>
<surname><![CDATA[Moya]]></surname>
<given-names><![CDATA[A]]></given-names>
</name>
<name>
<surname><![CDATA[Rodríguez]]></surname>
<given-names><![CDATA[O]]></given-names>
</name>
<name>
<surname><![CDATA[Soler Soler]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Síndrome de Twiddler en un paciente portador de desfibrilador automático implantable: ¿una complicación evitable?]]></article-title>
<source><![CDATA[Rev Esp Cardiol]]></source>
<year>2001</year>
<volume>54</volume>
<numero>12</numero>
<issue>12</issue>
<page-range>1456-8</page-range></nlm-citation>
</ref>
<ref id="B10">
<label>10</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Ejima]]></surname>
<given-names><![CDATA[K]]></given-names>
</name>
<name>
<surname><![CDATA[Shoda]]></surname>
<given-names><![CDATA[M]]></given-names>
</name>
<name>
<surname><![CDATA[Manaka]]></surname>
<given-names><![CDATA[T]]></given-names>
</name>
<name>
<surname><![CDATA[Hagiwara]]></surname>
<given-names><![CDATA[N]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Reel syndrome]]></article-title>
<source><![CDATA[J Cardiovasc Electrophysiol]]></source>
<year>2009</year>
<volume>20</volume>
<numero>7</numero>
<issue>7</issue>
<page-range>822</page-range></nlm-citation>
</ref>
<ref id="B11">
<label>11</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[van Rees]]></surname>
<given-names><![CDATA[JB]]></given-names>
</name>
<name>
<surname><![CDATA[de Bie]]></surname>
<given-names><![CDATA[MK]]></given-names>
</name>
<name>
<surname><![CDATA[Thijssen]]></surname>
<given-names><![CDATA[J]]></given-names>
</name>
<name>
<surname><![CDATA[Borleffs]]></surname>
<given-names><![CDATA[CJ]]></given-names>
</name>
<name>
<surname><![CDATA[Schalij]]></surname>
<given-names><![CDATA[MJ]]></given-names>
</name>
<name>
<surname><![CDATA[van Erven]]></surname>
<given-names><![CDATA[L]]></given-names>
</name>
</person-group>
<article-title xml:lang="en"><![CDATA[Implantation-related complications of implantable cardioverter-defibrillators and cardiac resynchronization therapy devices: a systematic review of randomized clinical trials]]></article-title>
<source><![CDATA[J Am Coll Cardiol]]></source>
<year>2011</year>
<volume>58</volume>
<numero>10</numero>
<issue>10</issue>
<page-range>995-1000</page-range></nlm-citation>
</ref>
<ref id="B12">
<label>12</label><nlm-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname><![CDATA[Echeverri]]></surname>
<given-names><![CDATA[D]]></given-names>
</name>
<name>
<surname><![CDATA[Barón]]></surname>
<given-names><![CDATA[AM]]></given-names>
</name>
<name>
<surname><![CDATA[García]]></surname>
<given-names><![CDATA[JC]]></given-names>
</name>
<name>
<surname><![CDATA[Ramírez]]></surname>
<given-names><![CDATA[JD]]></given-names>
</name>
</person-group>
<article-title xml:lang="es"><![CDATA[Síndrome de reel: una variante del síndrome de Twiddler]]></article-title>
<source><![CDATA[Rev Colomb Cardiol]]></source>
<year>2015</year>
<volume>22</volume>
<numero>3</numero>
<issue>3</issue>
<page-range>153-5</page-range></nlm-citation>
</ref>
</ref-list>
</back>
</article>