SciELO - Scientific Electronic Library Online

 
vol.22 issue1Motivation and satisfaction of myopic patients undergoing LASIK surgeryVisual results achieved in patients with pure astigmatism corrected with LASIK author indexsubject indexarticles search
Home Pagealphabetic serial listing  

Services on Demand

Article

Indicators

  • Have no cited articlesCited by SciELO

Related links

  • Have no similar articlesSimilars in SciELO

Share


Revista Cubana de Oftalmología

On-line version ISSN 1561-3070

Abstract

DIAZ MARTINEZ, Tania Aymeé; TORRES ORTEGA, Rosario; HERNANDEZ COBAS, Coralia  and  MARCOLETA GOYANES, Rosa María. Topographic results achieved patients wearing contact lens. Rev Cubana Oftalmol [online]. 2009, vol.22, n.1, pp. 0-0. ISSN 1561-3070.

OBJECTIVES: To analyze the topographic results achieved in patients wearing contact lens, who were candidates to refractive surgery with Excimer laser at "Carlos J. Finlay" hospital; to determine the behaviour according to age and sex; to find out the type of contact lens used and the length of wear; and to identify the relationship of the induced corneal topographic pattern in contact lens wearers with corneal warpage and ketatoconus. METHODS: A retrospective study of the corneal topography of candidates to refractive surgery in the last 2 years was performed in 80 patients (contact lens wearers). OPTIKON AMF510P and HUMPHREY topographers were the instruments to screen the patients. All of them were performed a complete ophthalmological exam (manifest refraction, biomicroscopy, keratometry, pachymetry and corneal topography). Results and their stability were compared. Also age, sex, type of lenses and length of wear were analyzed. RESULTS: One hundred and fifty eight eyes were treated, 83 of them presented with normal topographic pattern whereas 58 had contact lens-induced corneal warpage and 17 suffered keratoconus. The average age of patients was 27 years. Mean corneal astigmatism in patients with keratoconus was -3.25 D and in patients with corneal warpage -1.12 D. The reading of the most even meridian in patients with keratocomus was 46,75 dioptries and with corneal warpage was 43,25 D. As to keratoconus, the most curved meridian reading was 54,75 dioptres and in corneal warpage was 46 dioptres. CONCLUSIONS: The type of contact lens and the length of wear has an effect on the occurrence of induced corneal warpage and subclinical keratoconus, and both recorded a similar topographic pattern.

Keywords : Corneal topography; keratoconus; corneal warpage; contact lenses.

        · abstract in Spanish     · text in Spanish     · Spanish ( pdf )

 

Creative Commons License All the contents of this journal, except where otherwise noted, is licensed under a Creative Commons Attribution License